Facility Name:DENVER UNIT CO 2 RECOVERY PLANT
Facility Identifier:
Facility Reporting Year:2023
Facility Location:
Address: 1.5 M N OF DENVER CITY ON SH 214
City: DENVER CITY
State: TX
Postal Code: 79323

Facility Site Details:
CO2 equivalent emissions from facility subparts C-II, SS, and TT (metric tons):99,720.7
CO2 equivalent emissions from supplier subparts LL-QQ (metric tons):
Biogenic CO2 emissions from facility subparts C-II, SS, and TT (metric tons):0
Cogeneration Unit Emissions Indicator:N
GHG Report Start Date:2023-01-01
GHG Report End Date:2023-12-31
Description of Changes to Calculation Methodology:
Plant Code Indicator:N
Primary NAICS Code:211120
Second Primary NAICS Code:

Parent Company Details:
Parent Company Name:PENROC OIL CORP
Address:1515 W Calle Sur St Ste 174, Hobbs,  NM 88240
Percent Ownership Interest:1
Parent Company Name:EXXON MOBIL CORP
Address:5959 Las Colinas Blvd, Irving,  TX 75039
Percent Ownership Interest:12
Parent Company Name:COTERRA ENERGY INC
Address:840 Gessner Road, Suite 1400, Houston,  TX 77024
Percent Ownership Interest:1
Parent Company Name:CHEVRON CORP
Address:6001 Bollinger Canyon Road, San Ramon,  CA 94583
Percent Ownership Interest:17
Parent Company Name:CONOCOPHILLIPS
Address:925 N Eldridge Pkwy, Houston,  TX 77079
Percent Ownership Interest:14
Parent Company Name:ARIEL EXPLORATION INC
Address:500 N Akard St Ste 1900, Dallas,  TX 75201
Percent Ownership Interest:1
Parent Company Name:OCCIDENTAL PETROLEUM CORP
Address:5 Greenway Plaza, Suite 110, Houston,  TX 77046
Percent Ownership Interest:53
Parent Company Name:DEVON ENERGY CORP
Address:333 West Sheridan Avenue, Oklahoma City,  OK 73102
Percent Ownership Interest:1

Subpart C: General Stationary Fuel Combustion

Gas Information Details

Gas NameCarbon Dioxide
Gas Quantity58,788.7 (Metric Tons)
Own Result?

Gas NameBiogenic Carbon dioxide
Gas Quantity0 (Metric Tons)
Own Result?

Gas NameMethane
Gas Quantity1.11 (Metric Tons)
Own Result?

Gas NameNitrous Oxide
Gas Quantity0.111 (Metric Tons)
Own Result?

Unit Details:
Unit Name : GP- Denver Unit CO2 Recovery Plant
Unit Description :
Small Unit Aggregation Details:
Use Ivt Indicator: Y
Highest Maximum Rated Heat Input Capacity: 123
Cumulative Maximum Rated Heat Input Capacity: 235

Emission Details:
Annual CO2 mass emissions from sorbent: 0 (Metric Tons)
Annual Biogenic CO2 Emissions: 0 (metric tons)
Annual Fossil fuel based CO2 Emissions: 58788.6 (metric tons)

Tier Fuel Details:
Fuel : Natural Gas (Weighted U.S. Average)
Tier Name : Tier 2 (Equation C-2a)
Tier Methodology Start Date : 2023-01-01
Tier Methodology End Date : 2023-12-31
Frequency of HHV determinations : Semiannually

Tier 2 Monthly HHV Details :
JanuaryFebruaryMarchAprilMayJuneJulyAugustSeptemberOctoberNovemberDecember
Y N N N N N N N Y N N N

Fuel Emission Details :
Total CO2 emissionsTotal CH4 emissionsTotal N2O emissionsTotal CH4 emissions CO2eTotal N2O emissions CO2e
58784.3 (Metric Tons) 1.11 (Metric Tons) 0.111 (Metric Tons) 27.7 (Metric Tons) 33 (Metric Tons)


Fuel : Distillate Fuel Oil No. 2
Tier Name : Tier 1 (Equation C-1)
Tier Methodology Start Date : 2023-01-01
Tier Methodology End Date : 2023-12-31

Fuel Emission Details :
Total CO2 emissionsTotal CH4 emissionsTotal N2O emissionsTotal CH4 emissions CO2eTotal N2O emissions CO2e
4.4 (Metric Tons) 0.00 (Metric Tons) 0.000 (Metric Tons) 0 (Metric Tons) 0 (Metric Tons)



Subpart W: Petroleum and Natural Gas Systems

Gas Information Details

Gas NameCarbon Dioxide
Gas Quantity20,325.7 (Metric Tons)
Own Result?

Gas NameMethane
Gas Quantity821.7 (Metric Tons)
Own Result?

Gas NameNitrous Oxide
Gas Quantity0.01 (Metric Tons)
Own Result?


SubpartWSummaryDetails:
Industry Segment Number3
Industry Segment NameOnshore natural gas processing [98.230(a)(3)]
Total Reported CO2 Emissions (mt CO2)20325.7
Total CO2e Emissions (mt CO2e)40871.3
Total Reported CH4 Emissions (mt CH4)821.70
Total Reported N2O Emissions (mt N2O)0.010


SubpartWSourceReportingFormRowDetails:
Source Reporting FormOnshore Production [98.236(aa)(1)]
Required for Selected Industry SegmentNo
Source Reporting FormFacility Overview [98.236(aa)(2-11)]
Required for Selected Industry SegmentYes
Source Reporting FormNatural Gas Pneumatic Devices [98.236(b)]
Required for Selected Industry SegmentNo
Total Reported CO2 Emissions (mt CO2)0.0
Total Reported CH4 Emissions (mt CH4)0.00
Source Reporting FormNatural Gas Driven Pneumatic Pumps [98.236(c)]
Required for Selected Industry SegmentNo
Total Reported CO2 Emissions (mt CO2)0.0
Total Reported CH4 Emissions (mt CH4)0.00
Source Reporting FormAcid Gas Removal Units [98.236(d)]
Required for Selected Industry SegmentYes
Total Reported CO2 Emissions (mt CO2)0.0
Source Reporting FormDehydrators [98.236(e)]
Required for Selected Industry SegmentYes
Total Reported CO2 Emissions (mt CO2)0.0
Total Reported CH4 Emissions (mt CH4)0.00
Total Reported N2O Emissions (mt N2O)0.000
Source Reporting FormWell Venting for Liquids Unloading [98.236(f)]
Required for Selected Industry SegmentNo
Total Reported CO2 Emissions (mt CO2)0.0
Total Reported CH4 Emissions (mt CH4)0.00
Source Reporting FormCompletions and Workovers with Hydraulic Fracturing [98.236(g)]
Required for Selected Industry SegmentNo
Total Reported CO2 Emissions (mt CO2)0.0
Total Reported CH4 Emissions (mt CH4)0.00
Total Reported N2O Emissions (mt N2O)0.000
Source Reporting FormCompletions and Workovers without Hydraulic Fracturing [98.236(h)]
Required for Selected Industry SegmentNo
Total Reported CO2 Emissions (mt CO2)0.0
Total Reported CH4 Emissions (mt CH4)0.00
Total Reported N2O Emissions (mt N2O)0.000
Source Reporting FormBlowdown Vent Stacks [98.236(i)]
Required for Selected Industry SegmentYes
Total Reported CO2 Emissions (mt CO2)500.8
Total Reported CH4 Emissions (mt CH4)788.91
Source Reporting FormAtmospheric Storage Tanks [98.236(j)]
Required for Selected Industry SegmentNo
Total Reported CO2 Emissions (mt CO2)0.0
Total Reported CH4 Emissions (mt CH4)0.00
Total Reported N2O Emissions (mt N2O)0.000
Source Reporting FormTransmission Storage Tanks [98.236(k)]
Required for Selected Industry SegmentNo
Total Reported CO2 Emissions (mt CO2)0.0
Total Reported CH4 Emissions (mt CH4)0.00
Total Reported N2O Emissions (mt N2O)0.000
Source Reporting FormWell Testing [98.236(l)]
Required for Selected Industry SegmentNo
Total Reported CO2 Emissions (mt CO2)0.0
Total Reported CH4 Emissions (mt CH4)0.00
Total Reported N2O Emissions (mt N2O)0.000
Source Reporting FormAssociated Gas Venting and Flaring [98.236(m)]
Required for Selected Industry SegmentNo
Total Reported CO2 Emissions (mt CO2)0.0
Total Reported CH4 Emissions (mt CH4)0.00
Total Reported N2O Emissions (mt N2O)0.000
Source Reporting FormFlare Stacks [98.236(n)]
Required for Selected Industry SegmentYes
Total Reported CO2 Emissions (mt CO2)19239.0
Total Reported CH4 Emissions (mt CH4)19.72
Total Reported N2O Emissions (mt N2O)0.010
Source Reporting FormCentrifugal Compressors [98.236(o)]
Required for Selected Industry SegmentYes
Total Reported CO2 Emissions (mt CO2)0.0
Total Reported CH4 Emissions (mt CH4)0.00
Source Reporting FormReciprocating Compressors [98.236(p)]
Required for Selected Industry SegmentYes
Total Reported CO2 Emissions (mt CO2)270.6
Total Reported CH4 Emissions (mt CH4)6.04
Source Reporting FormEquipment Leaks Surveys and Population Counts [98.236(q,r)]
Required for Selected Industry SegmentYes
Total Reported CO2 Emissions (mt CO2)315.3
Total Reported CH4 Emissions (mt CH4)7.03
Source Reporting FormOffshore Petroleum and Natural Gas Production [98.236(s)]
Required for Selected Industry SegmentNo
Total Reported CO2 Emissions (mt CO2)0.0
Total Reported CH4 Emissions (mt CH4)0.00
Total Reported N2O Emissions (mt N2O)0.000
Source Reporting FormEnhanced Oil Recovery Injection Pumps [98.236(w)]
Required for Selected Industry SegmentNo
Total Reported CO2 Emissions (mt CO2)0.0
Source Reporting FormEnhanced Oil Recovery Hydrocarbon Liquids [98.236(x)]
Required for Selected Industry SegmentNo
Total Reported CO2 Emissions (mt CO2)0.0
Source Reporting FormCombustion Equipment at Onshore Petroleum and Natural Gas Production Facilities, Onshore Petroleum and Natural Gas Gathering and Boosting Facilities, and Natural gas Distribution Facilities [98.236(z)]
Required for Selected Industry SegmentNo
Total Reported CO2 Emissions (mt CO2)0.0
Total Reported CH4 Emissions (mt CH4)0.00
Total Reported N2O Emissions (mt N2O)0.000


FacilityOverviewDetails:


FacilityOverviewNaturalGasProcessingRowDetails:
Average mole fraction of CH4 in natural gas received [98.236(aa)(3)(v)]0.05495
Average mole fraction of CO2 in natural gas received [98.236(aa)(3)(vi)]0.89898
Does the facility fractionate NGLs? [98.236(aa)(3)(vii)]No


AcidGasRemovalUnitsDetails:
mt CO20.0
Did the Facility have any acid gas removal units that vent directly to the atmosphere, to a flare or engine, or to a sulfur recovery plant subject to reporting under 98.232 [98.236(d)]?Yes
Were missing data procedures used for any parameters to calculate GHG emissions? [98.235]No


AcidGasInfoRowDetails:
Unit ID or Name [98.236(d)(1)(i)]Amine Unit (AGR-1)
Total feed rate entering the acid gas removal unit for the year (million cubic feet) [98.236(d)(1)(ii)]5421.582
Calculation Method Used (Select from list) [98.236(d)(1)(iii)]Calculation Methodology 3 [98.233(d)(3)]
Are any CO2 emissions from the acid gas removal unit recovered and transferred outside the facility? (Yes / No) [98.236(d)(1)(iv)]Yes
Total CO2 Emissions (mt CO2) [98.236(d)(1)(v)]0


AcidGasCalcMethod3EmissionsRowDetails:
Unit ID or Name [98.236(d)(1)(i)]Amine Unit (AGR-1)
Equation Used (W-4A/W-4B) [98.236(d)(2)(ii)(A)]W-4A
Annual average fraction of CO2 content of natural gas into the acid gas removal unit, Voli (volumetric fraction) [98.236(d)(2)(ii)(C)]0.89898
Annual average fraction of CO2 content of natural gas out of the acid gas removal unit, Volo (volumetric fraction) [98.236(d)(2)(ii)(B)]0.00914
Natural gas flow rate into the acid gas removal unit, Vin (actual or standard cubic feet) (Eq. W-4A) [98.236(d)(2)(ii)(D)]5421582000
Natural gas flow rate reported on an Actual or Standard basis? [98.236]Standard
Temperature used to calculate natural gas flow rate (°F) [98.236]60
Pressure used to calculate natural gas flow rate (psi) [98.236]14.7


DehydratorsDetails:
mt CO20.0
mt CH40.00
mt N2O0.000
Did the facility have any glycol dehydrators with annual average daily natural gas throughputs greater than or equal to 0.4MMscfd subject to reporting under 98.232 [98.236(e)]?No
Did the facility have any glycol dehydrators with annual average daily natural gas throughputs less than 0.4MMscfd subject to reporting under 98.232 [98.236(e)]?No
Did the facility have any desiccant dehydrators subject to reporting under 98.232 [98.236(e)]?Yes
Were missing data procedures used for any parameters to calculate GHG emissions? [98.235]No


SmallGlycolDehydrators:
Emissions vented to flare or regenerator firebox/fire tubes
Emissions that were not vented to a flare or regenerator firebox/fire tubes


DessicantDehydrators:
Total Number of Desiccant Dehydrators [98.236(e)(3)(i)]7
Vapor RecoveryYes
Number of Desiccant Dehydrators By Vent Control Type, Count [98.236(e)(3)(i)]7
Dehydrator vents to flares or regenerator firebox/fire tubesNo
Control devices other than vapor recovery, flare or regenerator firebox/fire tubesNo
Emissions vented to flare or regenerator firebox/fire tubes
Emissions that were not vented to a flare or regenerator firebox/fire tubes
Total CO2 Emissions (mt CO2) [98.236(e)(3)(i)] [98.236(e)(3)(ii)]0
Total CH4 Emissions (mt CH4) [98.236(e)(3)(i)] [98.236(e)(3)(iii)]0


BlowdownVentStacksDetails:
mt CO2500.8
mt CH4788.91
Did the facility have any blowdown vent stacks subject to reporting under 98.232 [98.236(i)]?Yes
Were missing data procedures used for any parameters to calculate GHG emissions? [98.235]No
How were emissions determined? [98.236(i)]Using flow meters


BlowdownVentStacksEmissionsRowDetails:
Annual total CO2 emissions calculated by flow meter (mt CO2) [98.236(i)(2)(i)]500.7775649
Annual total CH4 emissions calculated by flow meter (mt CH4) [98.236(i)(2)(ii)]788.9148114


FlareStacksDetails:
mt CO219239.0
mt CH419.72
mt N2O0.010
Did the facility have flare stacks subject to reporting under 98.232 [98.236(n)]?Yes
Were missing data procedures used for any parameters to calculate GHG emissions? [98.235]No


UniqueFlareStacksRowDetails:
Unique Name or ID Number for the Flare Stack [98.236(n)(1)]DUCRP
Does the flare stack have a continuous flow monitor on gas to the flare? [98.236(n)(2)]No
Does the flare stack have a continuous gas analyzer on gas to the flare? [98.236(n)(3)]No
Were CEMS used to measure CO2 emissions for the flare stack? [98.233(n)(8)] [98.236(n)(12)]No
Volume of gas sent to flare, Vs (standard cubic feet) [98.236(n)(4)]5411890
Flare combustion efficiency (decimal value) [98.236(n)(6)]0.98
Mole fraction of CH4 in flare feed gas, XCH4 [98.236(n)(7)]0.1476384
Mole fraction of CO2 in flare feed gas, XCO2 [98.236(n)(8)]0.8277572
Fraction of feed gas sent to un-lit flare, Zu [98.236(n)(5)]0
CO2 emissions (mt CO2) [98.236(n)(9)]272.1863493
CH4 Emissions (mt CH4) (Eq. W-19) [98.236(n)(10)]0.301492
N2O Emissions (mt N2O) (Eq. W-40) [98.236(n)(11)]0.0000981
Unique Name or ID Number for the Flare Stack [98.236(n)(1)]PV-109B
Does the flare stack have a continuous flow monitor on gas to the flare? [98.236(n)(2)]No
Does the flare stack have a continuous gas analyzer on gas to the flare? [98.236(n)(3)]No
Were CEMS used to measure CO2 emissions for the flare stack? [98.233(n)(8)] [98.236(n)(12)]No
Volume of gas sent to flare, Vs (standard cubic feet) [98.236(n)(4)]5089650
Flare combustion efficiency (decimal value) [98.236(n)(6)]0.98
Mole fraction of CH4 in flare feed gas, XCH4 [98.236(n)(7)]0.769382
Mole fraction of CO2 in flare feed gas, XCO2 [98.236(n)(8)]0.0596167
Fraction of feed gas sent to un-lit flare, Zu [98.236(n)(5)]0
CO2 emissions (mt CO2) [98.236(n)(9)]212.5714778
CH4 Emissions (mt CH4) (Eq. W-19) [98.236(n)(10)]1.4672073
N2O Emissions (mt N2O) (Eq. W-40) [98.236(n)(11)]0.000367
Unique Name or ID Number for the Flare Stack [98.236(n)(1)]PV-109B2
Does the flare stack have a continuous flow monitor on gas to the flare? [98.236(n)(2)]No
Does the flare stack have a continuous gas analyzer on gas to the flare? [98.236(n)(3)]No
Were CEMS used to measure CO2 emissions for the flare stack? [98.233(n)(8)] [98.236(n)(12)]No
Volume of gas sent to flare, Vs (standard cubic feet) [98.236(n)(4)]5630000
Flare combustion efficiency (decimal value) [98.236(n)(6)]0.98
Mole fraction of CH4 in flare feed gas, XCH4 [98.236(n)(7)]0.7693153
Mole fraction of CO2 in flare feed gas, XCO2 [98.236(n)(8)]0.0596115
Fraction of feed gas sent to un-lit flare, Zu [98.236(n)(5)]0
CO2 emissions (mt CO2) [98.236(n)(9)]243.7635481
CH4 Emissions (mt CH4) (Eq. W-19) [98.236(n)(10)]1.6825123
N2O Emissions (mt N2O) (Eq. W-40) [98.236(n)(11)]0.000406
Unique Name or ID Number for the Flare Stack [98.236(n)(1)]PV-1101B
Does the flare stack have a continuous flow monitor on gas to the flare? [98.236(n)(2)]No
Does the flare stack have a continuous gas analyzer on gas to the flare? [98.236(n)(3)]No
Were CEMS used to measure CO2 emissions for the flare stack? [98.233(n)(8)] [98.236(n)(12)]No
Volume of gas sent to flare, Vs (standard cubic feet) [98.236(n)(4)]23267280
Flare combustion efficiency (decimal value) [98.236(n)(6)]0.98
Mole fraction of CH4 in flare feed gas, XCH4 [98.236(n)(7)]0.8426409
Mole fraction of CO2 in flare feed gas, XCO2 [98.236(n)(8)]0.0032755
Fraction of feed gas sent to un-lit flare, Zu [98.236(n)(5)]0
CO2 emissions (mt CO2) [98.236(n)(9)]1023.8207603
CH4 Emissions (mt CH4) (Eq. W-19) [98.236(n)(10)]7.5967324
N2O Emissions (mt N2O) (Eq. W-40) [98.236(n)(11)]0.0017992
Unique Name or ID Number for the Flare Stack [98.236(n)(1)]PV-111
Does the flare stack have a continuous flow monitor on gas to the flare? [98.236(n)(2)]No
Does the flare stack have a continuous gas analyzer on gas to the flare? [98.236(n)(3)]No
Were CEMS used to measure CO2 emissions for the flare stack? [98.233(n)(8)] [98.236(n)(12)]No
Volume of gas sent to flare, Vs (standard cubic feet) [98.236(n)(4)]435000
Flare combustion efficiency (decimal value) [98.236(n)(6)]0.98
Mole fraction of CH4 in flare feed gas, XCH4 [98.236(n)(7)]0.71082
Mole fraction of CO2 in flare feed gas, XCO2 [98.236(n)(8)]0.18987
Fraction of feed gas sent to un-lit flare, Zu [98.236(n)(5)]0
CO2 emissions (mt CO2) [98.236(n)(9)]20.2878983
CH4 Emissions (mt CH4) (Eq. W-19) [98.236(n)(10)]0.1187354
N2O Emissions (mt N2O) (Eq. W-40) [98.236(n)(11)]0.0000288
Unique Name or ID Number for the Flare Stack [98.236(n)(1)]PV-12
Does the flare stack have a continuous flow monitor on gas to the flare? [98.236(n)(2)]No
Does the flare stack have a continuous gas analyzer on gas to the flare? [98.236(n)(3)]No
Were CEMS used to measure CO2 emissions for the flare stack? [98.233(n)(8)] [98.236(n)(12)]No
Volume of gas sent to flare, Vs (standard cubic feet) [98.236(n)(4)]183653770
Flare combustion efficiency (decimal value) [98.236(n)(6)]0.98
Mole fraction of CH4 in flare feed gas, XCH4 [98.236(n)(7)]0.0595392
Mole fraction of CO2 in flare feed gas, XCO2 [98.236(n)(8)]0.8697219
Fraction of feed gas sent to un-lit flare, Zu [98.236(n)(5)]0
CO2 emissions (mt CO2) [98.236(n)(9)]9085.2589895
CH4 Emissions (mt CH4) (Eq. W-19) [98.236(n)(10)]4.2431471
N2O Emissions (mt N2O) (Eq. W-40) [98.236(n)(11)]0.0029493
Unique Name or ID Number for the Flare Stack [98.236(n)(1)]PV-121B
Does the flare stack have a continuous flow monitor on gas to the flare? [98.236(n)(2)]No
Does the flare stack have a continuous gas analyzer on gas to the flare? [98.236(n)(3)]No
Were CEMS used to measure CO2 emissions for the flare stack? [98.233(n)(8)] [98.236(n)(12)]No
Volume of gas sent to flare, Vs (standard cubic feet) [98.236(n)(4)]4130000
Flare combustion efficiency (decimal value) [98.236(n)(6)]0.98
Mole fraction of CH4 in flare feed gas, XCH4 [98.236(n)(7)]0
Mole fraction of CO2 in flare feed gas, XCO2 [98.236(n)(8)]0.0324
Fraction of feed gas sent to un-lit flare, Zu [98.236(n)(5)]0
CO2 emissions (mt CO2) [98.236(n)(9)]13.7090951
CH4 Emissions (mt CH4) (Eq. W-19) [98.236(n)(10)]0
N2O Emissions (mt N2O) (Eq. W-40) [98.236(n)(11)]0.0009909
Unique Name or ID Number for the Flare Stack [98.236(n)(1)]PV-12B
Does the flare stack have a continuous flow monitor on gas to the flare? [98.236(n)(2)]No
Does the flare stack have a continuous gas analyzer on gas to the flare? [98.236(n)(3)]No
Were CEMS used to measure CO2 emissions for the flare stack? [98.233(n)(8)] [98.236(n)(12)]No
Volume of gas sent to flare, Vs (standard cubic feet) [98.236(n)(4)]157665330
Flare combustion efficiency (decimal value) [98.236(n)(6)]0.98
Mole fraction of CH4 in flare feed gas, XCH4 [98.236(n)(7)]0.0594986
Mole fraction of CO2 in flare feed gas, XCO2 [98.236(n)(8)]0.8690405
Fraction of feed gas sent to un-lit flare, Zu [98.236(n)(5)]0
CO2 emissions (mt CO2) [98.236(n)(9)]7784.8243112
CH4 Emissions (mt CH4) (Eq. W-19) [98.236(n)(10)]3.6366381
N2O Emissions (mt N2O) (Eq. W-40) [98.236(n)(11)]0.0025489
Unique Name or ID Number for the Flare Stack [98.236(n)(1)]PV-3008
Does the flare stack have a continuous flow monitor on gas to the flare? [98.236(n)(2)]No
Does the flare stack have a continuous gas analyzer on gas to the flare? [98.236(n)(3)]No
Were CEMS used to measure CO2 emissions for the flare stack? [98.233(n)(8)] [98.236(n)(12)]No
Volume of gas sent to flare, Vs (standard cubic feet) [98.236(n)(4)]1037000
Flare combustion efficiency (decimal value) [98.236(n)(6)]0.98
Mole fraction of CH4 in flare feed gas, XCH4 [98.236(n)(7)]0.0587738
Mole fraction of CO2 in flare feed gas, XCO2 [98.236(n)(8)]0.8517863
Fraction of feed gas sent to un-lit flare, Zu [98.236(n)(5)]0
CO2 emissions (mt CO2) [98.236(n)(9)]49.6700238
CH4 Emissions (mt CH4) (Eq. W-19) [98.236(n)(10)]0.0234042
N2O Emissions (mt N2O) (Eq. W-40) [98.236(n)(11)]0.0000184
Unique Name or ID Number for the Flare Stack [98.236(n)(1)]PV-43B
Does the flare stack have a continuous flow monitor on gas to the flare? [98.236(n)(2)]No
Does the flare stack have a continuous gas analyzer on gas to the flare? [98.236(n)(3)]No
Were CEMS used to measure CO2 emissions for the flare stack? [98.233(n)(8)] [98.236(n)(12)]No
Volume of gas sent to flare, Vs (standard cubic feet) [98.236(n)(4)]187200
Flare combustion efficiency (decimal value) [98.236(n)(6)]0.98
Mole fraction of CH4 in flare feed gas, XCH4 [98.236(n)(7)]0.0870827
Mole fraction of CO2 in flare feed gas, XCO2 [98.236(n)(8)]0.7302579
Fraction of feed gas sent to un-lit flare, Zu [98.236(n)(5)]0
CO2 emissions (mt CO2) [98.236(n)(9)]8.722496
CH4 Emissions (mt CH4) (Eq. W-19) [98.236(n)(10)]0.0067342
N2O Emissions (mt N2O) (Eq. W-40) [98.236(n)(11)]0.0000062
Unique Name or ID Number for the Flare Stack [98.236(n)(1)]PV-44B
Does the flare stack have a continuous flow monitor on gas to the flare? [98.236(n)(2)]No
Does the flare stack have a continuous gas analyzer on gas to the flare? [98.236(n)(3)]No
Were CEMS used to measure CO2 emissions for the flare stack? [98.233(n)(8)] [98.236(n)(12)]No
Volume of gas sent to flare, Vs (standard cubic feet) [98.236(n)(4)]171420
Flare combustion efficiency (decimal value) [98.236(n)(6)]0.98
Mole fraction of CH4 in flare feed gas, XCH4 [98.236(n)(7)]0.0103924
Mole fraction of CO2 in flare feed gas, XCO2 [98.236(n)(8)]0.436693
Fraction of feed gas sent to un-lit flare, Zu [98.236(n)(5)]0
CO2 emissions (mt CO2) [98.236(n)(9)]4.9727795
CH4 Emissions (mt CH4) (Eq. W-19) [98.236(n)(10)]0.0007184
N2O Emissions (mt N2O) (Eq. W-40) [98.236(n)(11)]0.0000224
Unique Name or ID Number for the Flare Stack [98.236(n)(1)]PV-93B
Does the flare stack have a continuous flow monitor on gas to the flare? [98.236(n)(2)]No
Does the flare stack have a continuous gas analyzer on gas to the flare? [98.236(n)(3)]No
Were CEMS used to measure CO2 emissions for the flare stack? [98.233(n)(8)] [98.236(n)(12)]No
Volume of gas sent to flare, Vs (standard cubic feet) [98.236(n)(4)]1421000
Flare combustion efficiency (decimal value) [98.236(n)(6)]0.98
Mole fraction of CH4 in flare feed gas, XCH4 [98.236(n)(7)]0.0679925
Mole fraction of CO2 in flare feed gas, XCO2 [98.236(n)(8)]0.8485117
Fraction of feed gas sent to un-lit flare, Zu [98.236(n)(5)]0
CO2 emissions (mt CO2) [98.236(n)(9)]71.6542761
CH4 Emissions (mt CH4) (Eq. W-19) [98.236(n)(10)]0.038662
N2O Emissions (mt N2O) (Eq. W-40) [98.236(n)(11)]0.0000147
Unique Name or ID Number for the Flare Stack [98.236(n)(1)]PV-96B
Does the flare stack have a continuous flow monitor on gas to the flare? [98.236(n)(2)]No
Does the flare stack have a continuous gas analyzer on gas to the flare? [98.236(n)(3)]No
Were CEMS used to measure CO2 emissions for the flare stack? [98.233(n)(8)] [98.236(n)(12)]No
Volume of gas sent to flare, Vs (standard cubic feet) [98.236(n)(4)]215000
Flare combustion efficiency (decimal value) [98.236(n)(6)]0.98
Mole fraction of CH4 in flare feed gas, XCH4 [98.236(n)(7)]0.45873
Mole fraction of CO2 in flare feed gas, XCO2 [98.236(n)(8)]0.44087
Fraction of feed gas sent to un-lit flare, Zu [98.236(n)(5)]0
CO2 emissions (mt CO2) [98.236(n)(9)]10.0766146
CH4 Emissions (mt CH4) (Eq. W-19) [98.236(n)(10)]0.0378727
N2O Emissions (mt N2O) (Eq. W-40) [98.236(n)(11)]0.00001
Unique Name or ID Number for the Flare Stack [98.236(n)(1)]V-110
Does the flare stack have a continuous flow monitor on gas to the flare? [98.236(n)(2)]No
Does the flare stack have a continuous gas analyzer on gas to the flare? [98.236(n)(3)]No
Were CEMS used to measure CO2 emissions for the flare stack? [98.233(n)(8)] [98.236(n)(12)]No
Volume of gas sent to flare, Vs (standard cubic feet) [98.236(n)(4)]462000
Flare combustion efficiency (decimal value) [98.236(n)(6)]0.98
Mole fraction of CH4 in flare feed gas, XCH4 [98.236(n)(7)]0.0487723
Mole fraction of CO2 in flare feed gas, XCO2 [98.236(n)(8)]0.0001361
Fraction of feed gas sent to un-lit flare, Zu [98.236(n)(5)]0
CO2 emissions (mt CO2) [98.236(n)(9)]1.2428309
CH4 Emissions (mt CH4) (Eq. W-19) [98.236(n)(10)]0.0086526
N2O Emissions (mt N2O) (Eq. W-40) [98.236(n)(11)]0.0000482
Unique Name or ID Number for the Flare Stack [98.236(n)(1)]V-111
Does the flare stack have a continuous flow monitor on gas to the flare? [98.236(n)(2)]No
Does the flare stack have a continuous gas analyzer on gas to the flare? [98.236(n)(3)]No
Were CEMS used to measure CO2 emissions for the flare stack? [98.233(n)(8)] [98.236(n)(12)]No
Volume of gas sent to flare, Vs (standard cubic feet) [98.236(n)(4)]2360860
Flare combustion efficiency (decimal value) [98.236(n)(6)]0.98
Mole fraction of CH4 in flare feed gas, XCH4 [98.236(n)(7)]0.390011
Mole fraction of CO2 in flare feed gas, XCO2 [98.236(n)(8)]0.0566406
Fraction of feed gas sent to un-lit flare, Zu [98.236(n)(5)]0
CO2 emissions (mt CO2) [98.236(n)(9)]56.3151244
CH4 Emissions (mt CH4) (Eq. W-19) [98.236(n)(10)]0.3538074
N2O Emissions (mt N2O) (Eq. W-40) [98.236(n)(11)]0.0003507
Unique Name or ID Number for the Flare Stack [98.236(n)(1)]V-112
Does the flare stack have a continuous flow monitor on gas to the flare? [98.236(n)(2)]No
Does the flare stack have a continuous gas analyzer on gas to the flare? [98.236(n)(3)]No
Were CEMS used to measure CO2 emissions for the flare stack? [98.233(n)(8)] [98.236(n)(12)]No
Volume of gas sent to flare, Vs (standard cubic feet) [98.236(n)(4)]8593640
Flare combustion efficiency (decimal value) [98.236(n)(6)]0.98
Mole fraction of CH4 in flare feed gas, XCH4 [98.236(n)(7)]0.05513
Mole fraction of CO2 in flare feed gas, XCO2 [98.236(n)(8)]0.7350633
Fraction of feed gas sent to un-lit flare, Zu [98.236(n)(5)]0
CO2 emissions (mt CO2) [98.236(n)(9)]359.8561224
CH4 Emissions (mt CH4) (Eq. W-19) [98.236(n)(10)]0.1819267
N2O Emissions (mt N2O) (Eq. W-40) [98.236(n)(11)]0.0005148
Unique Name or ID Number for the Flare Stack [98.236(n)(1)]V-112B
Does the flare stack have a continuous flow monitor on gas to the flare? [98.236(n)(2)]No
Does the flare stack have a continuous gas analyzer on gas to the flare? [98.236(n)(3)]No
Were CEMS used to measure CO2 emissions for the flare stack? [98.233(n)(8)] [98.236(n)(12)]No
Volume of gas sent to flare, Vs (standard cubic feet) [98.236(n)(4)]369120
Flare combustion efficiency (decimal value) [98.236(n)(6)]0.98
Mole fraction of CH4 in flare feed gas, XCH4 [98.236(n)(7)]0.0606233
Mole fraction of CO2 in flare feed gas, XCO2 [98.236(n)(8)]0.88442
Fraction of feed gas sent to un-lit flare, Zu [98.236(n)(5)]0
CO2 emissions (mt CO2) [98.236(n)(9)]18.3496416
CH4 Emissions (mt CH4) (Eq. W-19) [98.236(n)(10)]0.0085929
N2O Emissions (mt N2O) (Eq. W-40) [98.236(n)(11)]0.0000058
Unique Name or ID Number for the Flare Stack [98.236(n)(1)]V-113
Does the flare stack have a continuous flow monitor on gas to the flare? [98.236(n)(2)]No
Does the flare stack have a continuous gas analyzer on gas to the flare? [98.236(n)(3)]No
Were CEMS used to measure CO2 emissions for the flare stack? [98.233(n)(8)] [98.236(n)(12)]No
Volume of gas sent to flare, Vs (standard cubic feet) [98.236(n)(4)]38870
Flare combustion efficiency (decimal value) [98.236(n)(6)]0.98
Mole fraction of CH4 in flare feed gas, XCH4 [98.236(n)(7)]0.6726567
Mole fraction of CO2 in flare feed gas, XCO2 [98.236(n)(8)]0.18723
Fraction of feed gas sent to un-lit flare, Zu [98.236(n)(5)]0
CO2 emissions (mt CO2) [98.236(n)(9)]1.731205
CH4 Emissions (mt CH4) (Eq. W-19) [98.236(n)(10)]0.0100401
N2O Emissions (mt N2O) (Eq. W-40) [98.236(n)(11)]0.0000025


CentrifugalCompressorsDetails:
mt CO20.0
mt CH40.00
Did the facility have any centrifugal compressors subject to reporting under 98.232 [98.236(o)]?Yes
Were missing data procedures used for any parameters to calculate GHG emissions? [98.235]No


CentrifugalCompressorsActivityDataRowDetails:
Compressor ID or Unique Name [98.236(o)(1)(i)]K-1E Inlet/Demeth Compressor
Total time in operating-mode (hours) [98.236(o)(1)(ii)]3440
Total time in not-operating-depressurized-mode (hours) [98.236(o)(1)(iii)]5003.5
Compressor measured in operating-mode? [98.236(o)(1)(iv)]No
Compressor measured in not-operating-depressurized-mode? [98.236(o)(1)(v)]Yes
Compressor had blind flanges installed? [98.236(o)(1)(x)]No
Seal Type (wet or dry) [98.236(o)(1)(xi)]Dry
Power output of compressor driver (hp) [98.236(o)(1)(xiii)]3000
Compressor had scheduled depressurized shutdown during reporting year? [98.236(o)(1)(xiv)]Yes


CentrifugalCompressorsCompressorSourceRowDetails:
Unique Compressor Name or ID [98.236(o)(2)(i)(A)]K-1E Inlet/Demeth Compressor
Centrifugal compressor source [98.236(o)(2)(i)(B)]Blowdown valve
Unique Name or ID for leak or vent [98.236(o)(2)(i)(C)]K-1E Inlet/Demeth Compressor_BD
Unique Compressor Name or ID [98.236(o)(2)(i)(A)]K-1E Inlet/Demeth Compressor
Centrifugal compressor source [98.236(o)(2)(i)(B)]Isolation valve
Unique Name or ID for leak or vent [98.236(o)(2)(i)(C)]K-1E Inlet/Demeth Compressor_IV
Unique Compressor Name or ID [98.236(o)(2)(i)(A)]K-1E Inlet/Demeth Compressor
Centrifugal compressor source [98.236(o)(2)(i)(B)]Wet seal


CentrifugalCompressorsEmissionFactorsSampleDataRowDetails:
Compressor Mode [98.236(o)(3)(ii)(A)]Operating
Compressor Source [98.236(o)(3)(ii)(A)]Wet seal
Compressor mode-source combination reporter emission factor, EFs,m (standard cubic feet per hour) [98.236(o)(3)(ii)(B)]0
Total number of compressors measured in the compressor mode-source combination in current reporting year and preceding two reporting years [98.236(o)(3)(ii)(C)]3
Is the reporter emission factor facility-specific or based on all of the reporter's applicable facilities? [98.236(o)(3)(ii)(D)]Facility-specific
Compressor Mode [98.236(o)(3)(ii)(A)]Operating
Compressor Source [98.236(o)(3)(ii)(A)]Blowdown valve
Compressor mode-source combination reporter emission factor, EFs,m (standard cubic feet per hour) [98.236(o)(3)(ii)(B)]0
Total number of compressors measured in the compressor mode-source combination in current reporting year and preceding two reporting years [98.236(o)(3)(ii)(C)]3
Is the reporter emission factor facility-specific or based on all of the reporter's applicable facilities? [98.236(o)(3)(ii)(D)]Facility-specific
Compressor Mode [98.236(o)(3)(ii)(A)]Not-operating
Compressor Source [98.236(o)(3)(ii)(A)]Isolation valve
Compressor mode-source combination reporter emission factor, EFs,m (standard cubic feet per hour) [98.236(o)(3)(ii)(B)]0
Total number of compressors measured in the compressor mode-source combination in current reporting year and preceding two reporting years [98.236(o)(3)(ii)(C)]3
Is the reporter emission factor facility-specific or based on all of the reporter's applicable facilities? [98.236(o)(3)(ii)(D)]Facility-specific


CentrifugalCompressorsLeakOrVentDataRowDetails:
Unique Name or ID for leak or vent [98.236(o)(2)(i)(C)]K-1E Inlet/Demeth Compressor_BD
Leak or vent for a single compressor source or a manifolded group? [98.236(o)(2)(ii)(A)] [98.236(o)(1)(vi)]Single
Where are leak or vent emissions released? [98.236(o)(2)(ii)(A)] [98.236(o)(1)(vii) through (ix)]Flare
Percentage of time the device was operational when compressor source emissions were routed to device [98.236(o)(2)(ii)(E)]1
Unique Name or ID for leak or vent [98.236(o)(2)(i)(C)]K-1E Inlet/Demeth Compressor_IV
Leak or vent for a single compressor source or a manifolded group? [98.236(o)(2)(ii)(A)] [98.236(o)(1)(vi)]Single
Where are leak or vent emissions released? [98.236(o)(2)(ii)(A)] [98.236(o)(1)(vii) through (ix)]Flare
Percentage of time the device was operational when compressor source emissions were routed to device [98.236(o)(2)(ii)(E)]1


ReciprocatingCompressorsDetails:
mt CO2270.6
mt CH46.04
Did the facility have any reciprocating compressors subject to reporting under 98.232 [98.236(p)]?Yes
Were missing data procedures used for any parameters to calculate GHG emissions? [98.235]No


ReciprocatingCompressorsActivityDataRowDetails:
Unique name or ID for reciprocating compressor [98.236(p)(1)(i)]K-5A Recycle CO2 Compressor
Total time in operating-mode (hours) [98.236(p)(1)(ii)]8306.5
Total time in standby-pressurized-mode (hours) [98.236(p)(1)(iii)]449
Total time in not-operating-depressurized-mode (hours) [98.236(p)(1)(iv)]5
Compressor measured in operating-mode? [98.236(p)(1)(v)]Yes
Compressor measured in standby-pressurized-mode? [98.236(p)(1)(vi)]No
Compressor measured in not-operating-depressurized-mode? [98.236(p)(1)(vii)]No
Compressor had blind flanges installed? [98.236(p)(1)(xii)]No
Power output of compressor driver (hp) [98.236(p)(1)(xiii)]1000
Compressor had scheduled depressurized shutdown during reporting year? [98.236(p)(1)(xiv)]No
Unique name or ID for reciprocating compressor [98.236(p)(1)(i)]K-5B Recycle CO2 Compressor
Total time in operating-mode (hours) [98.236(p)(1)(ii)]8509
Total time in standby-pressurized-mode (hours) [98.236(p)(1)(iii)]248
Total time in not-operating-depressurized-mode (hours) [98.236(p)(1)(iv)]3
Compressor measured in operating-mode? [98.236(p)(1)(v)]Yes
Compressor measured in standby-pressurized-mode? [98.236(p)(1)(vi)]No
Compressor measured in not-operating-depressurized-mode? [98.236(p)(1)(vii)]No
Compressor had blind flanges installed? [98.236(p)(1)(xii)]No
Power output of compressor driver (hp) [98.236(p)(1)(xiii)]1000
Compressor had scheduled depressurized shutdown during reporting year? [98.236(p)(1)(xiv)]No
Unique name or ID for reciprocating compressor [98.236(p)(1)(i)]K-5C Recycle CO2 Compressor
Total time in operating-mode (hours) [98.236(p)(1)(ii)]8493.5
Total time in standby-pressurized-mode (hours) [98.236(p)(1)(iii)]240
Total time in not-operating-depressurized-mode (hours) [98.236(p)(1)(iv)]27
Compressor measured in operating-mode? [98.236(p)(1)(v)]Yes
Compressor measured in standby-pressurized-mode? [98.236(p)(1)(vi)]No
Compressor measured in not-operating-depressurized-mode? [98.236(p)(1)(vii)]No
Compressor had blind flanges installed? [98.236(p)(1)(xii)]No
Power output of compressor driver (hp) [98.236(p)(1)(xiii)]1000
Compressor had scheduled depressurized shutdown during reporting year? [98.236(p)(1)(xiv)]No
Unique name or ID for reciprocating compressor [98.236(p)(1)(i)]K-1D Inlet/Demeth Compressor
Total time in operating-mode (hours) [98.236(p)(1)(ii)]8412.5
Total time in standby-pressurized-mode (hours) [98.236(p)(1)(iii)]300
Total time in not-operating-depressurized-mode (hours) [98.236(p)(1)(iv)]48
Compressor measured in operating-mode? [98.236(p)(1)(v)]Yes
Compressor measured in standby-pressurized-mode? [98.236(p)(1)(vi)]No
Compressor measured in not-operating-depressurized-mode? [98.236(p)(1)(vii)]No
Compressor had blind flanges installed? [98.236(p)(1)(xii)]No
Power output of compressor driver (hp) [98.236(p)(1)(xiii)]3000
Compressor had scheduled depressurized shutdown during reporting year? [98.236(p)(1)(xiv)]No
Unique name or ID for reciprocating compressor [98.236(p)(1)(i)]K-1C Inlet/Demeth Compressor
Total time in operating-mode (hours) [98.236(p)(1)(ii)]8103
Total time in standby-pressurized-mode (hours) [98.236(p)(1)(iii)]651
Total time in not-operating-depressurized-mode (hours) [98.236(p)(1)(iv)]6
Compressor measured in operating-mode? [98.236(p)(1)(v)]Yes
Compressor measured in standby-pressurized-mode? [98.236(p)(1)(vi)]No
Compressor measured in not-operating-depressurized-mode? [98.236(p)(1)(vii)]No
Compressor had blind flanges installed? [98.236(p)(1)(xii)]No
Power output of compressor driver (hp) [98.236(p)(1)(xiii)]3000
Compressor had scheduled depressurized shutdown during reporting year? [98.236(p)(1)(xiv)]No
Unique name or ID for reciprocating compressor [98.236(p)(1)(i)]K-1B Inlet/Demeth Compressor
Total time in operating-mode (hours) [98.236(p)(1)(ii)]8332
Total time in standby-pressurized-mode (hours) [98.236(p)(1)(iii)]372
Total time in not-operating-depressurized-mode (hours) [98.236(p)(1)(iv)]56
Compressor measured in operating-mode? [98.236(p)(1)(v)]Yes
Compressor measured in standby-pressurized-mode? [98.236(p)(1)(vi)]No
Compressor measured in not-operating-depressurized-mode? [98.236(p)(1)(vii)]No
Compressor had blind flanges installed? [98.236(p)(1)(xii)]No
Power output of compressor driver (hp) [98.236(p)(1)(xiii)]3000
Compressor had scheduled depressurized shutdown during reporting year? [98.236(p)(1)(xiv)]No
Unique name or ID for reciprocating compressor [98.236(p)(1)(i)]K-1A Inlet/Demeth Compressor
Total time in operating-mode (hours) [98.236(p)(1)(ii)]8655.5
Total time in standby-pressurized-mode (hours) [98.236(p)(1)(iii)]70
Total time in not-operating-depressurized-mode (hours) [98.236(p)(1)(iv)]35
Compressor measured in operating-mode? [98.236(p)(1)(v)]Yes
Compressor measured in standby-pressurized-mode? [98.236(p)(1)(vi)]No
Compressor measured in not-operating-depressurized-mode? [98.236(p)(1)(vii)]No
Compressor had blind flanges installed? [98.236(p)(1)(xii)]No
Power output of compressor driver (hp) [98.236(p)(1)(xiii)]3000
Compressor had scheduled depressurized shutdown during reporting year? [98.236(p)(1)(xiv)]No
Unique name or ID for reciprocating compressor [98.236(p)(1)(i)]K-4A Dehy. Regen Compressor
Total time in operating-mode (hours) [98.236(p)(1)(ii)]8320
Total time in standby-pressurized-mode (hours) [98.236(p)(1)(iii)]440
Total time in not-operating-depressurized-mode (hours) [98.236(p)(1)(iv)]0
Compressor measured in operating-mode? [98.236(p)(1)(v)]Yes
Compressor measured in standby-pressurized-mode? [98.236(p)(1)(vi)]No
Compressor measured in not-operating-depressurized-mode? [98.236(p)(1)(vii)]No
Compressor had blind flanges installed? [98.236(p)(1)(xii)]No
Power output of compressor driver (hp) [98.236(p)(1)(xiii)]200
Compressor had scheduled depressurized shutdown during reporting year? [98.236(p)(1)(xiv)]No
Unique name or ID for reciprocating compressor [98.236(p)(1)(i)]K-4B Dehy. Regen Compressor
Total time in operating-mode (hours) [98.236(p)(1)(ii)]8320
Total time in standby-pressurized-mode (hours) [98.236(p)(1)(iii)]440
Total time in not-operating-depressurized-mode (hours) [98.236(p)(1)(iv)]0
Compressor measured in operating-mode? [98.236(p)(1)(v)]Yes
Compressor measured in standby-pressurized-mode? [98.236(p)(1)(vi)]No
Compressor measured in not-operating-depressurized-mode? [98.236(p)(1)(vii)]No
Compressor had blind flanges installed? [98.236(p)(1)(xii)]No
Power output of compressor driver (hp) [98.236(p)(1)(xiii)]200
Compressor had scheduled depressurized shutdown during reporting year? [98.236(p)(1)(xiv)]No
Unique name or ID for reciprocating compressor [98.236(p)(1)(i)]K-9 Compressor
Total time in operating-mode (hours) [98.236(p)(1)(ii)]8038.5
Total time in standby-pressurized-mode (hours) [98.236(p)(1)(iii)]650
Total time in not-operating-depressurized-mode (hours) [98.236(p)(1)(iv)]72
Compressor measured in operating-mode? [98.236(p)(1)(v)]Yes
Compressor measured in standby-pressurized-mode? [98.236(p)(1)(vi)]No
Compressor measured in not-operating-depressurized-mode? [98.236(p)(1)(vii)]No
Compressor had blind flanges installed? [98.236(p)(1)(xii)]No
Power output of compressor driver (hp) [98.236(p)(1)(xiii)]2250
Compressor had scheduled depressurized shutdown during reporting year? [98.236(p)(1)(xiv)]No


ReciprocatingCompressorSourceRowDetails:
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]K-5A Recycle CO2 Compressor
Reciprocating compressor source [98.236(p)(2)(i)(B)]Blowdown valve
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]K-5A Recycle CO2 Compressor_BD
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]K-5A Recycle CO2 Compressor
Reciprocating compressor source [98.236(p)(2)(i)(B)]Isolation valve
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]K-5A Recycle CO2 Compressor_IV
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]K-5A Recycle CO2 Compressor
Reciprocating compressor source [98.236(p)(2)(i)(B)]Rod packing
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]K-5A Recycle CO2 Compressor_RP
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]K-5B Recycle CO2 Compressor
Reciprocating compressor source [98.236(p)(2)(i)(B)]Blowdown valve
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]K-5B Recycle CO2 Compressor_BD
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]K-5B Recycle CO2 Compressor
Reciprocating compressor source [98.236(p)(2)(i)(B)]Isolation valve
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]K-5B Recycle CO2 Compressor_IV
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]K-5B Recycle CO2 Compressor
Reciprocating compressor source [98.236(p)(2)(i)(B)]Rod packing
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]K-5B Recycle CO2 Compressor_RP
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]K-5C Recycle CO2 Compressor
Reciprocating compressor source [98.236(p)(2)(i)(B)]Blowdown valve
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]K-5C Recycle CO2 Compressor_BD
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]K-5C Recycle CO2 Compressor
Reciprocating compressor source [98.236(p)(2)(i)(B)]Isolation valve
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]K-5C Recycle CO2 Compressor_IV
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]K-5C Recycle CO2 Compressor
Reciprocating compressor source [98.236(p)(2)(i)(B)]Rod packing
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]K-5C Recycle CO2 Compressor_RP
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]K-1D Inlet/Demeth Compressor
Reciprocating compressor source [98.236(p)(2)(i)(B)]Blowdown valve
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]K-1D Inlet/Demeth Compressor_BD
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]K-1D Inlet/Demeth Compressor
Reciprocating compressor source [98.236(p)(2)(i)(B)]Isolation valve
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]K-1D Inlet/Demeth Compressor_IV
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]K-1D Inlet/Demeth Compressor
Reciprocating compressor source [98.236(p)(2)(i)(B)]Rod packing
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]K-1D Inlet/Demeth Compressor_RP
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]K-1C Inlet/Demeth Compressor
Reciprocating compressor source [98.236(p)(2)(i)(B)]Blowdown valve
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]K-1C Inlet/Demeth Compressor_BD
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]K-1C Inlet/Demeth Compressor
Reciprocating compressor source [98.236(p)(2)(i)(B)]Isolation valve
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]K-1C Inlet/Demeth Compressor_IV
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]K-1C Inlet/Demeth Compressor
Reciprocating compressor source [98.236(p)(2)(i)(B)]Rod packing
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]K-1C Inlet/Demeth Compressor_RP
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]K-1B Inlet/Demeth Compressor
Reciprocating compressor source [98.236(p)(2)(i)(B)]Blowdown valve
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]K-1B Inlet/Demeth Compressor_BD
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]K-1B Inlet/Demeth Compressor
Reciprocating compressor source [98.236(p)(2)(i)(B)]Isolation valve
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]K-1B Inlet/Demeth Compressor_IV
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]K-1B Inlet/Demeth Compressor
Reciprocating compressor source [98.236(p)(2)(i)(B)]Rod packing
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]K-1B Inlet/Demeth Compressor_RP
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]K-1A Inlet/Demeth Compressor
Reciprocating compressor source [98.236(p)(2)(i)(B)]Blowdown valve
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]K-1A Inlet/Demeth Compressor_BD
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]K-1A Inlet/Demeth Compressor
Reciprocating compressor source [98.236(p)(2)(i)(B)]Isolation valve
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]K-1A Inlet/Demeth Compressor_IV
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]K-1A Inlet/Demeth Compressor
Reciprocating compressor source [98.236(p)(2)(i)(B)]Rod packing
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]K-1A Inlet/Demeth Compressor_RP
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]K-4A Dehy. Regen Compressor
Reciprocating compressor source [98.236(p)(2)(i)(B)]Blowdown valve
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]K-4A Dehy. Regen Compressor_BD
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]K-4A Dehy. Regen Compressor
Reciprocating compressor source [98.236(p)(2)(i)(B)]Isolation valve
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]K-4A Dehy. Regen Compressor_IV
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]K-4A Dehy. Regen Compressor
Reciprocating compressor source [98.236(p)(2)(i)(B)]Rod packing
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]K-4A Dehy. Regen Compressor_RP
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]K-4B Dehy. Regen Compressor
Reciprocating compressor source [98.236(p)(2)(i)(B)]Blowdown valve
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]K-4B Dehy. Regen Compressor_BD
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]K-4B Dehy. Regen Compressor
Reciprocating compressor source [98.236(p)(2)(i)(B)]Isolation valve
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]K-4B Dehy. Regen Compressor_IV
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]K-4B Dehy. Regen Compressor
Reciprocating compressor source [98.236(p)(2)(i)(B)]Rod packing
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]K-4B Dehy. Regen Compressor_RP
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]K-9 Compressor
Reciprocating compressor source [98.236(p)(2)(i)(B)]Blowdown valve
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]K-9 Compressor_BD
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]K-9 Compressor
Reciprocating compressor source [98.236(p)(2)(i)(B)]Isolation valve
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]K-9 Compressor_IV
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]K-9 Compressor
Reciprocating compressor source [98.236(p)(2)(i)(B)]Rod packing
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]K-9 Compressor_RP


ReciprocatingCompressorsLeakOrVentSampleDataRowDetails:
Unique Name or ID for leak or vent (Specify) [98.236(p)(2)(i)(C)] [98.236(p)(3)(i)(A)]K-5A Recycle CO2 Compressor_RP
Measurement date (mm/dd/yyyy) [98.236(p)(3)(i)(B)]2023-08-19
Measurement method [98.236(p)(3)(i)(C)]Screening/Optical gas imaging
Measured flow rate (standard cubic feet/hour) [98.236(p)(3)(i)(D)]0
Is the measurement location prior to or after commingling with non-compressor emission sources? [98.236(p)(3)(i)(F)]Not manifolded
Compressors in “Operating mode”K-5A Recycle CO2 Compressor_RP
Unique Name or ID for leak or vent (Specify) [98.236(p)(2)(i)(C)] [98.236(p)(3)(i)(A)]K-5B Recycle CO2 Compressor_RP
Measurement date (mm/dd/yyyy) [98.236(p)(3)(i)(B)]2023-08-19
Measurement method [98.236(p)(3)(i)(C)]Screening/Optical gas imaging
Measured flow rate (standard cubic feet/hour) [98.236(p)(3)(i)(D)]0
Is the measurement location prior to or after commingling with non-compressor emission sources? [98.236(p)(3)(i)(F)]Not manifolded
Compressors in “Operating mode”K-5B Recycle CO2 Compressor_RP
Unique Name or ID for leak or vent (Specify) [98.236(p)(2)(i)(C)] [98.236(p)(3)(i)(A)]K-5C Recycle CO2 Compressor_RP
Measurement date (mm/dd/yyyy) [98.236(p)(3)(i)(B)]2023-08-19
Measurement method [98.236(p)(3)(i)(C)]Temporary meter
Measured flow rate (standard cubic feet/hour) [98.236(p)(3)(i)(D)]3.00438
Is the measurement location prior to or after commingling with non-compressor emission sources? [98.236(p)(3)(i)(F)]Not manifolded
Compressors in “Operating mode”K-5C Recycle CO2 Compressor_RP
Unique Name or ID for leak or vent (Specify) [98.236(p)(2)(i)(C)] [98.236(p)(3)(i)(A)]K-1D Inlet/Demeth Compressor_RP
Measurement date (mm/dd/yyyy) [98.236(p)(3)(i)(B)]2023-08-19
Measurement method [98.236(p)(3)(i)(C)]High volume sampler
Measured flow rate (standard cubic feet/hour) [98.236(p)(3)(i)(D)]12
Is the measurement location prior to or after commingling with non-compressor emission sources? [98.236(p)(3)(i)(F)]Not manifolded
Compressors in “Operating mode”K-1D Inlet/Demeth Compressor_RP
Unique Name or ID for leak or vent (Specify) [98.236(p)(2)(i)(C)] [98.236(p)(3)(i)(A)]K-1C Inlet/Demeth Compressor_RP
Measurement date (mm/dd/yyyy) [98.236(p)(3)(i)(B)]2023-08-19
Measurement method [98.236(p)(3)(i)(C)]Screening/Optical gas imaging
Measured flow rate (standard cubic feet/hour) [98.236(p)(3)(i)(D)]0
Is the measurement location prior to or after commingling with non-compressor emission sources? [98.236(p)(3)(i)(F)]Not manifolded
Compressors in “Operating mode”K-1C Inlet/Demeth Compressor_RP
Unique Name or ID for leak or vent (Specify) [98.236(p)(2)(i)(C)] [98.236(p)(3)(i)(A)]K-1B Inlet/Demeth Compressor_RP
Measurement date (mm/dd/yyyy) [98.236(p)(3)(i)(B)]2023-08-19
Measurement method [98.236(p)(3)(i)(C)]High volume sampler
Measured flow rate (standard cubic feet/hour) [98.236(p)(3)(i)(D)]67.2
Is the measurement location prior to or after commingling with non-compressor emission sources? [98.236(p)(3)(i)(F)]Not manifolded
Compressors in “Operating mode”K-1B Inlet/Demeth Compressor_RP
Unique Name or ID for leak or vent (Specify) [98.236(p)(2)(i)(C)] [98.236(p)(3)(i)(A)]K-1A Inlet/Demeth Compressor_RP
Measurement date (mm/dd/yyyy) [98.236(p)(3)(i)(B)]2023-08-19
Measurement method [98.236(p)(3)(i)(C)]High volume sampler
Measured flow rate (standard cubic feet/hour) [98.236(p)(3)(i)(D)]5.7
Is the measurement location prior to or after commingling with non-compressor emission sources? [98.236(p)(3)(i)(F)]Not manifolded
Compressors in “Operating mode”K-1A Inlet/Demeth Compressor_RP
Unique Name or ID for leak or vent (Specify) [98.236(p)(2)(i)(C)] [98.236(p)(3)(i)(A)]K-4A Dehy. Regen Compressor_BD
Measurement date (mm/dd/yyyy) [98.236(p)(3)(i)(B)]2023-08-19
Measurement method [98.236(p)(3)(i)(C)]Screening/Optical gas imaging
Measured flow rate (standard cubic feet/hour) [98.236(p)(3)(i)(D)]0
Is the measurement location prior to or after commingling with non-compressor emission sources? [98.236(p)(3)(i)(F)]Not manifolded
Compressors in “Operating mode”K-4A Dehy. Regen Compressor_BD
Unique Name or ID for leak or vent (Specify) [98.236(p)(2)(i)(C)] [98.236(p)(3)(i)(A)]K-4A Dehy. Regen Compressor_RP
Measurement date (mm/dd/yyyy) [98.236(p)(3)(i)(B)]2023-08-19
Measurement method [98.236(p)(3)(i)(C)]High volume sampler
Measured flow rate (standard cubic feet/hour) [98.236(p)(3)(i)(D)]0.12
Is the measurement location prior to or after commingling with non-compressor emission sources? [98.236(p)(3)(i)(F)]Not manifolded
Compressors in “Operating mode”K-4A Dehy. Regen Compressor_RP
Unique Name or ID for leak or vent (Specify) [98.236(p)(2)(i)(C)] [98.236(p)(3)(i)(A)]K-4B Dehy. Regen Compressor_BD
Measurement date (mm/dd/yyyy) [98.236(p)(3)(i)(B)]2023-08-19
Measurement method [98.236(p)(3)(i)(C)]Acoustic leak detection
Measured flow rate (standard cubic feet/hour) [98.236(p)(3)(i)(D)]1.02
Is the measurement location prior to or after commingling with non-compressor emission sources? [98.236(p)(3)(i)(F)]Not manifolded
Compressors in “Operating mode”K-4B Dehy. Regen Compressor_BD
Unique Name or ID for leak or vent (Specify) [98.236(p)(2)(i)(C)] [98.236(p)(3)(i)(A)]K-4B Dehy. Regen Compressor_RP
Measurement date (mm/dd/yyyy) [98.236(p)(3)(i)(B)]2023-08-19
Measurement method [98.236(p)(3)(i)(C)]High volume sampler
Measured flow rate (standard cubic feet/hour) [98.236(p)(3)(i)(D)]0.42
Is the measurement location prior to or after commingling with non-compressor emission sources? [98.236(p)(3)(i)(F)]Not manifolded
Compressors in “Operating mode”K-4B Dehy. Regen Compressor_RP
Unique Name or ID for leak or vent (Specify) [98.236(p)(2)(i)(C)] [98.236(p)(3)(i)(A)]K-9 Compressor_BD
Measurement date (mm/dd/yyyy) [98.236(p)(3)(i)(B)]2023-08-19
Measurement method [98.236(p)(3)(i)(C)]Acoustic leak detection
Measured flow rate (standard cubic feet/hour) [98.236(p)(3)(i)(D)]0
Is the measurement location prior to or after commingling with non-compressor emission sources? [98.236(p)(3)(i)(F)]Not manifolded
Compressors in “Operating mode”K-9 Compressor_BD
Unique Name or ID for leak or vent (Specify) [98.236(p)(2)(i)(C)] [98.236(p)(3)(i)(A)]K-9 Compressor_RP
Measurement date (mm/dd/yyyy) [98.236(p)(3)(i)(B)]2023-08-19
Measurement method [98.236(p)(3)(i)(C)]High volume sampler
Measured flow rate (standard cubic feet/hour) [98.236(p)(3)(i)(D)]618.6
Is the measurement location prior to or after commingling with non-compressor emission sources? [98.236(p)(3)(i)(F)]Not manifolded
Compressors in “Operating mode”K-9 Compressor_RP


ReciprocatingCompressorsEmissionFactorsSampleDataRowDetails:
Compressor Mode [98.236(p)(3)(ii)(A)]Operating
Compressor Source [98.236(p)(3)(ii)(A)]Blowdown valve
Compressor mode-source combination reporter emission factor, EFs,m (standard cubic feet per hour) [98.236(p)(3)(ii)(B)]1.762062
Total number of compressors measured in the compressor mode-source combination in current reporting year and preceding two reporting years, Countm [98.236(p)(3)(ii)(C)]30
Is the reporter emission factor facility-specific or based on all of the reporter's applicable facilities? [98.236(p)(3)(ii)(D)]Facility-specific
Compressor Mode [98.236(p)(3)(ii)(A)]Operating
Compressor Source [98.236(p)(3)(ii)(A)]Rod packing
Compressor mode-source combination reporter emission factor, EFs,m (standard cubic feet per hour) [98.236(p)(3)(ii)(B)]37.068862
Total number of compressors measured in the compressor mode-source combination in current reporting year and preceding two reporting years, Countm [98.236(p)(3)(ii)(C)]30
Is the reporter emission factor facility-specific or based on all of the reporter's applicable facilities? [98.236(p)(3)(ii)(D)]Facility-specific
Compressor Mode [98.236(p)(3)(ii)(A)]Standby-pressurized
Compressor Source [98.236(p)(3)(ii)(A)]Blowdown valve
Compressor mode-source combination reporter emission factor, EFs,m (standard cubic feet per hour) [98.236(p)(3)(ii)(B)]0
Total number of compressors measured in the compressor mode-source combination in current reporting year and preceding two reporting years, Countm [98.236(p)(3)(ii)(C)]30
Is the reporter emission factor facility-specific or based on all of the reporter's applicable facilities? [98.236(p)(3)(ii)(D)]Facility-specific
Compressor Mode [98.236(p)(3)(ii)(A)]Not-operating-depressurized
Compressor Source [98.236(p)(3)(ii)(A)]Isolation valve
Compressor mode-source combination reporter emission factor, EFs,m (standard cubic feet per hour) [98.236(p)(3)(ii)(B)]6.202692
Total number of compressors measured in the compressor mode-source combination in current reporting year and preceding two reporting years, Countm [98.236(p)(3)(ii)(C)]30
Is the reporter emission factor facility-specific or based on all of the reporter's applicable facilities? [98.236(p)(3)(ii)(D)]Facility-specific


ReciprocatingCompressorsLeakOrVentDataRowDetails:
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]K-5A Recycle CO2 Compressor_BD
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Flare
Percentage of time the device was operational when compressor source emissions were routed to device [98.236(p)(2)(ii)(E)]1
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]K-5A Recycle CO2 Compressor_IV
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]No
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)]0.0014665
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)]0.0000327
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]K-5A Recycle CO2 Compressor_RP
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]Yes
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)]0
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)]0
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]K-5B Recycle CO2 Compressor_BD
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Flare
Percentage of time the device was operational when compressor source emissions were routed to device [98.236(p)(2)(ii)(E)]1
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]K-5B Recycle CO2 Compressor_IV
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]No
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)]0.0008799
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)]0.0000196
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]K-5B Recycle CO2 Compressor_RP
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]Yes
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)]0
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)]0
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]K-5C Recycle CO2 Compressor_BD
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Flare
Percentage of time the device was operational when compressor source emissions were routed to device [98.236(p)(2)(ii)(E)]1
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]K-5C Recycle CO2 Compressor_IV
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]No
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)]0.0079192
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)]0.0001767
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]K-5C Recycle CO2 Compressor_RP
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]Yes
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)]1.2066389
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)]0.0269222
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]K-1D Inlet/Demeth Compressor_BD
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Flare
Percentage of time the device was operational when compressor source emissions were routed to device [98.236(p)(2)(ii)(E)]1
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]K-1D Inlet/Demeth Compressor_IV
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]No
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)]0.0140785
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)]0.0003141
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]K-1D Inlet/Demeth Compressor_RP
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]Yes
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)]4.7735568
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)]0.1065063
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]K-1C Inlet/Demeth Compressor_BD
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Flare
Percentage of time the device was operational when compressor source emissions were routed to device [98.236(p)(2)(ii)(E)]1
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]K-1C Inlet/Demeth Compressor_IV
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]No
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)]0.0017598
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)]0.0000393
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]K-1C Inlet/Demeth Compressor_RP
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]Yes
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)]0
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)]0
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]K-1B Inlet/Demeth Compressor_BD
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Flare
Percentage of time the device was operational when compressor source emissions were routed to device [98.236(p)(2)(ii)(E)]1
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]K-1B Inlet/Demeth Compressor_IV
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]No
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)]0.0164249
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)]0.0003665
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]K-1B Inlet/Demeth Compressor_RP
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]Yes
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)]26.476118
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)]0.5907279
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]K-1A Inlet/Demeth Compressor_BD
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Flare
Percentage of time the device was operational when compressor source emissions were routed to device [98.236(p)(2)(ii)(E)]1
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]K-1A Inlet/Demeth Compressor_IV
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]No
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)]0.0102656
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)]0.000229
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]K-1A Inlet/Demeth Compressor_RP
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]Yes
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)]2.3329358
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)]0.0520518
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]K-4A Dehy. Regen Compressor_BD
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]Yes
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)]0
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)]0
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]K-4A Dehy. Regen Compressor_IV
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]No
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)]0
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)]0
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]K-4A Dehy. Regen Compressor_RP
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]Yes
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)]0.0472107
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)]0.0010534
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]K-4B Dehy. Regen Compressor_BD
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]Yes
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)]0.4012909
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)]0.0089535
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]K-4B Dehy. Regen Compressor_IV
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]No
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)]0
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)]0
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]K-4B Dehy. Regen Compressor_RP
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]Yes
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)]0.1652374
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)]0.0036867
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]K-9 Compressor_BD
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]Yes
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)]0
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)]0
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]K-9 Compressor_IV
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]No
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)]0.0211178
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)]0.0004712
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]K-9 Compressor_RP
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]Yes
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)]235.1368554
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)]5.2463089


OtherEmissionsFromEquipmentLeaksDetails:
mt CO2315.3
mt CH47.03
Did this facility use leak surveys to calculate emissions from equipment leaks in accordance with 98.232 [per 98.236(q)]?Yes
Were missing data procedures used for any parameters to calculate GHG emissions? [98.235]No
Number of complete equipment leak surveys performed during the calendar year [98.236(q)(1)(i)]1
Optical gas imaging instrument as specified in §60.18 [98.234(a)(1)]Yes
Method 21 [98.234(a)(2)]No
Infrared laser beam illuminated instrument [98.234(a)(3)]No
Acoustic leak detection device [98.234(a)(5)]Yes
Optical gas imaging instrument as specified in §60.5397a [98.234(a)(6)]No
Method 21 as specified in §60.5397a [98.234(a)(7)]No


GasProcessingEmissionsFactorsRowDetails:
Component Type [98.236(q)(2)(i)]Compressor Components, Gas Service - Valve
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)]38
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)]8760
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)]233.5916841
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)]5.2118335
Component Type [98.236(q)(2)(i)]Compressor Components, Gas Service - Connector
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)]26
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)]8760
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)]60.2039569
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)]1.3432541
Component Type [98.236(q)(2)(i)]Compressor Components, Gas Service - Open-ended Line
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)]3
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)]8760
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)]21.4611738
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)]0.4788358
Component Type [98.236(q)(2)(i)]Compressor Components, Gas Service - Pressure Relief Valve
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)]0
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)]0
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)]0
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)]0
Component Type [98.236(q)(2)(i)]Compressor Components, Gas Service - Meter
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)]0
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)]0
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)]0
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)]0
Component Type [98.236(q)(2)(i)]Non-Compressor Components, Gas Service - Valve
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)]0
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)]0
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)]0
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)]0
Component Type [98.236(q)(2)(i)]Non-Compressor Components, Gas Service - Connector
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)]0
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)]0
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)]0
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)]0
Component Type [98.236(q)(2)(i)]Non-Compressor Components, Gas Service - Open-ended Line
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)]0
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)]0
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)]0
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)]0
Component Type [98.236(q)(2)(i)]Non-Compressor components, Gas Service - Pressure Relief Valve
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)]0
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)]0
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)]0
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)]0
Component Type [98.236(q)(2)(i)]Non-Compressor components, Gas Service - Meter
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)]0
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)]0
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)]0
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)]0