Source Reporting Form | Onshore Production [98.236(aa)(1)] |
Required for Selected Industry Segment | No |
Source Reporting Form | Facility Overview [98.236(aa)(2-11)] |
Required for Selected Industry Segment | Yes |
Source Reporting Form | Natural Gas Pneumatic Devices [98.236(b)] |
Required for Selected Industry Segment | No |
Total Reported CO2 Emissions (mt CO2) | 0.0 |
Total Reported CH4 Emissions (mt CH4) | 0.00 |
Source Reporting Form | Natural Gas Driven Pneumatic Pumps [98.236(c)] |
Required for Selected Industry Segment | No |
Total Reported CO2 Emissions (mt CO2) | 0.0 |
Total Reported CH4 Emissions (mt CH4) | 0.00 |
Source Reporting Form | Acid Gas Removal Units [98.236(d)] |
Required for Selected Industry Segment | Yes |
Total Reported CO2 Emissions (mt CO2) | 16919.0 |
Source Reporting Form | Dehydrators [98.236(e)] |
Required for Selected Industry Segment | Yes |
Total Reported CO2 Emissions (mt CO2) | 0.0 |
Total Reported CH4 Emissions (mt CH4) | 0.00 |
Total Reported N2O Emissions (mt N2O) | 0.000 |
Source Reporting Form | Well Venting for Liquids Unloading [98.236(f)] |
Required for Selected Industry Segment | No |
Total Reported CO2 Emissions (mt CO2) | 0.0 |
Total Reported CH4 Emissions (mt CH4) | 0.00 |
Source Reporting Form | Completions and Workovers with Hydraulic Fracturing [98.236(g)] |
Required for Selected Industry Segment | No |
Total Reported CO2 Emissions (mt CO2) | 0.0 |
Total Reported CH4 Emissions (mt CH4) | 0.00 |
Total Reported N2O Emissions (mt N2O) | 0.000 |
Source Reporting Form | Completions and Workovers without Hydraulic Fracturing [98.236(h)] |
Required for Selected Industry Segment | No |
Total Reported CO2 Emissions (mt CO2) | 0.0 |
Total Reported CH4 Emissions (mt CH4) | 0.00 |
Total Reported N2O Emissions (mt N2O) | 0.000 |
Source Reporting Form | Blowdown Vent Stacks [98.236(i)] |
Required for Selected Industry Segment | Yes |
Total Reported CO2 Emissions (mt CO2) | 4.1 |
Total Reported CH4 Emissions (mt CH4) | 2816.31 |
Source Reporting Form | Atmospheric Storage Tanks [98.236(j)] |
Required for Selected Industry Segment | No |
Total Reported CO2 Emissions (mt CO2) | 0.0 |
Total Reported CH4 Emissions (mt CH4) | 0.00 |
Total Reported N2O Emissions (mt N2O) | 0.000 |
Source Reporting Form | Transmission Storage Tanks [98.236(k)] |
Required for Selected Industry Segment | No |
Total Reported CO2 Emissions (mt CO2) | 0.0 |
Total Reported CH4 Emissions (mt CH4) | 0.00 |
Total Reported N2O Emissions (mt N2O) | 0.000 |
Source Reporting Form | Well Testing [98.236(l)] |
Required for Selected Industry Segment | No |
Total Reported CO2 Emissions (mt CO2) | 0.0 |
Total Reported CH4 Emissions (mt CH4) | 0.00 |
Total Reported N2O Emissions (mt N2O) | 0.000 |
Source Reporting Form | Associated Gas Venting and Flaring [98.236(m)] |
Required for Selected Industry Segment | No |
Total Reported CO2 Emissions (mt CO2) | 0.0 |
Total Reported CH4 Emissions (mt CH4) | 0.00 |
Total Reported N2O Emissions (mt N2O) | 0.000 |
Source Reporting Form | Flare Stacks [98.236(n)] |
Required for Selected Industry Segment | Yes |
Total Reported CO2 Emissions (mt CO2) | 13996.6 |
Total Reported CH4 Emissions (mt CH4) | 12.86 |
Total Reported N2O Emissions (mt N2O) | 0.008 |
Source Reporting Form | Centrifugal Compressors [98.236(o)] |
Required for Selected Industry Segment | Yes |
Total Reported CO2 Emissions (mt CO2) | 0.0 |
Total Reported CH4 Emissions (mt CH4) | 0.00 |
Source Reporting Form | Reciprocating Compressors [98.236(p)] |
Required for Selected Industry Segment | Yes |
Total Reported CO2 Emissions (mt CO2) | 46.5 |
Total Reported CH4 Emissions (mt CH4) | 1.23 |
Source Reporting Form | Equipment Leaks Surveys and Population Counts [98.236(q,r)] |
Required for Selected Industry Segment | Yes |
Total Reported CO2 Emissions (mt CO2) | 204.5 |
Total Reported CH4 Emissions (mt CH4) | 5.39 |
Source Reporting Form | Offshore Petroleum and Natural Gas Production [98.236(s)] |
Required for Selected Industry Segment | No |
Total Reported CO2 Emissions (mt CO2) | 0.0 |
Total Reported CH4 Emissions (mt CH4) | 0.00 |
Total Reported N2O Emissions (mt N2O) | 0.000 |
Source Reporting Form | Enhanced Oil Recovery Injection Pumps [98.236(w)] |
Required for Selected Industry Segment | No |
Total Reported CO2 Emissions (mt CO2) | 0.0 |
Source Reporting Form | Enhanced Oil Recovery Hydrocarbon Liquids [98.236(x)] |
Required for Selected Industry Segment | No |
Total Reported CO2 Emissions (mt CO2) | 0.0 |
Source Reporting Form | Combustion Equipment at Onshore Petroleum and Natural Gas Production Facilities, Onshore Petroleum and Natural Gas Gathering and Boosting Facilities, and Natural gas Distribution Facilities [98.236(z)] |
Required for Selected Industry Segment | No |
Total Reported CO2 Emissions (mt CO2) | 0.0 |
Total Reported CH4 Emissions (mt CH4) | 0.00 |
Total Reported N2O Emissions (mt N2O) | 0.000 |
Unique Name or ID Number for the Flare Stack [98.236(n)(1)] | FL1/GAS FLARING |
Does the flare stack have a continuous flow monitor on gas to the flare? [98.236(n)(2)] | No |
Does the flare stack have a continuous gas analyzer on gas to the flare? [98.236(n)(3)] | No |
Were CEMS used to measure CO2 emissions for the flare stack? [98.233(n)(8)] [98.236(n)(12)] | No |
Volume of gas sent to flare, Vs (standard cubic feet) [98.236(n)(4)] | 3118110 |
Flare combustion efficiency (decimal value) [98.236(n)(6)] | 0.98 |
Mole fraction of CH4 in flare feed gas, XCH4 [98.236(n)(7)] | 0.01198 |
Mole fraction of CO2 in flare feed gas, XCO2 [98.236(n)(8)] | 0.53055 |
Fraction of feed gas sent to un-lit flare, Zu [98.236(n)(5)] | 0 |
CO2 emissions (mt CO2) [98.236(n)(9)] | 374.116973 |
CH4 Emissions (mt CH4) (Eq. W-19) [98.236(n)(10)] | 0.0143443 |
N2O Emissions (mt N2O) (Eq. W-40) [98.236(n)(11)] | 0.0004339 |
Unique Name or ID Number for the Flare Stack [98.236(n)(1)] | PV-109B |
Does the flare stack have a continuous flow monitor on gas to the flare? [98.236(n)(2)] | No |
Does the flare stack have a continuous gas analyzer on gas to the flare? [98.236(n)(3)] | No |
Were CEMS used to measure CO2 emissions for the flare stack? [98.233(n)(8)] [98.236(n)(12)] | No |
Volume of gas sent to flare, Vs (standard cubic feet) [98.236(n)(4)] | 583000 |
Flare combustion efficiency (decimal value) [98.236(n)(6)] | 0.98 |
Mole fraction of CH4 in flare feed gas, XCH4 [98.236(n)(7)] | 0.78265 |
Mole fraction of CO2 in flare feed gas, XCO2 [98.236(n)(8)] | 0.02551 |
Fraction of feed gas sent to un-lit flare, Zu [98.236(n)(5)] | 0 |
CO2 emissions (mt CO2) [98.236(n)(9)] | 24.7776904 |
CH4 Emissions (mt CH4) (Eq. W-19) [98.236(n)(10)] | 0.1752134 |
N2O Emissions (mt N2O) (Eq. W-40) [98.236(n)(11)] | 0.0000474 |
Unique Name or ID Number for the Flare Stack [98.236(n)(1)] | PV-109B2 |
Does the flare stack have a continuous flow monitor on gas to the flare? [98.236(n)(2)] | No |
Does the flare stack have a continuous gas analyzer on gas to the flare? [98.236(n)(3)] | No |
Were CEMS used to measure CO2 emissions for the flare stack? [98.233(n)(8)] [98.236(n)(12)] | No |
Volume of gas sent to flare, Vs (standard cubic feet) [98.236(n)(4)] | 514370 |
Flare combustion efficiency (decimal value) [98.236(n)(6)] | 0.98 |
Mole fraction of CH4 in flare feed gas, XCH4 [98.236(n)(7)] | 0.78265 |
Mole fraction of CO2 in flare feed gas, XCO2 [98.236(n)(8)] | 0.02551 |
Fraction of feed gas sent to un-lit flare, Zu [98.236(n)(5)] | 0 |
CO2 emissions (mt CO2) [98.236(n)(9)] | 21.860893 |
CH4 Emissions (mt CH4) (Eq. W-19) [98.236(n)(10)] | 0.1545875 |
N2O Emissions (mt N2O) (Eq. W-40) [98.236(n)(11)] | 0.0000422 |
Unique Name or ID Number for the Flare Stack [98.236(n)(1)] | PV-1101B |
Does the flare stack have a continuous flow monitor on gas to the flare? [98.236(n)(2)] | No |
Does the flare stack have a continuous gas analyzer on gas to the flare? [98.236(n)(3)] | No |
Were CEMS used to measure CO2 emissions for the flare stack? [98.233(n)(8)] [98.236(n)(12)] | No |
Volume of gas sent to flare, Vs (standard cubic feet) [98.236(n)(4)] | 12239610 |
Flare combustion efficiency (decimal value) [98.236(n)(6)] | 0.98 |
Mole fraction of CH4 in flare feed gas, XCH4 [98.236(n)(7)] | 0.81142 |
Mole fraction of CO2 in flare feed gas, XCO2 [98.236(n)(8)] | 0.00009 |
Fraction of feed gas sent to un-lit flare, Zu [98.236(n)(5)] | 0 |
CO2 emissions (mt CO2) [98.236(n)(9)] | 520.9768543 |
CH4 Emissions (mt CH4) (Eq. W-19) [98.236(n)(10)] | 3.8136823 |
N2O Emissions (mt N2O) (Eq. W-40) [98.236(n)(11)] | 0.001061 |
Unique Name or ID Number for the Flare Stack [98.236(n)(1)] | PV-111 |
Does the flare stack have a continuous flow monitor on gas to the flare? [98.236(n)(2)] | No |
Does the flare stack have a continuous gas analyzer on gas to the flare? [98.236(n)(3)] | No |
Were CEMS used to measure CO2 emissions for the flare stack? [98.233(n)(8)] [98.236(n)(12)] | No |
Volume of gas sent to flare, Vs (standard cubic feet) [98.236(n)(4)] | 45850 |
Flare combustion efficiency (decimal value) [98.236(n)(6)] | 0.98 |
Mole fraction of CH4 in flare feed gas, XCH4 [98.236(n)(7)] | 0.71082 |
Mole fraction of CO2 in flare feed gas, XCO2 [98.236(n)(8)] | 0.18987 |
Fraction of feed gas sent to un-lit flare, Zu [98.236(n)(5)] | 0 |
CO2 emissions (mt CO2) [98.236(n)(9)] | 2.1853049 |
CH4 Emissions (mt CH4) (Eq. W-19) [98.236(n)(10)] | 0.012515 |
N2O Emissions (mt N2O) (Eq. W-40) [98.236(n)(11)] | 0.0000033 |
Unique Name or ID Number for the Flare Stack [98.236(n)(1)] | PV-12 |
Does the flare stack have a continuous flow monitor on gas to the flare? [98.236(n)(2)] | No |
Does the flare stack have a continuous gas analyzer on gas to the flare? [98.236(n)(3)] | No |
Were CEMS used to measure CO2 emissions for the flare stack? [98.233(n)(8)] [98.236(n)(12)] | No |
Volume of gas sent to flare, Vs (standard cubic feet) [98.236(n)(4)] | 82481530 |
Flare combustion efficiency (decimal value) [98.236(n)(6)] | 0.98 |
Mole fraction of CH4 in flare feed gas, XCH4 [98.236(n)(7)] | 0.08299 |
Mole fraction of CO2 in flare feed gas, XCO2 [98.236(n)(8)] | 0.84366 |
Fraction of feed gas sent to un-lit flare, Zu [98.236(n)(5)] | 0 |
CO2 emissions (mt CO2) [98.236(n)(9)] | 4744.7388255 |
CH4 Emissions (mt CH4) (Eq. W-19) [98.236(n)(10)] | 2.6285346 |
N2O Emissions (mt N2O) (Eq. W-40) [98.236(n)(11)] | 0.0018913 |
Unique Name or ID Number for the Flare Stack [98.236(n)(1)] | PV-121B |
Does the flare stack have a continuous flow monitor on gas to the flare? [98.236(n)(2)] | No |
Does the flare stack have a continuous gas analyzer on gas to the flare? [98.236(n)(3)] | No |
Were CEMS used to measure CO2 emissions for the flare stack? [98.233(n)(8)] [98.236(n)(12)] | No |
Volume of gas sent to flare, Vs (standard cubic feet) [98.236(n)(4)] | 738570 |
Flare combustion efficiency (decimal value) [98.236(n)(6)] | 0.98 |
Mole fraction of CH4 in flare feed gas, XCH4 [98.236(n)(7)] | 0 |
Mole fraction of CO2 in flare feed gas, XCO2 [98.236(n)(8)] | 0 |
Fraction of feed gas sent to un-lit flare, Zu [98.236(n)(5)] | 0 |
CO2 emissions (mt CO2) [98.236(n)(9)] | 0 |
CH4 Emissions (mt CH4) (Eq. W-19) [98.236(n)(10)] | 0 |
N2O Emissions (mt N2O) (Eq. W-40) [98.236(n)(11)] | 0.0001809 |
Unique Name or ID Number for the Flare Stack [98.236(n)(1)] | PV-12B |
Does the flare stack have a continuous flow monitor on gas to the flare? [98.236(n)(2)] | No |
Does the flare stack have a continuous gas analyzer on gas to the flare? [98.236(n)(3)] | No |
Were CEMS used to measure CO2 emissions for the flare stack? [98.233(n)(8)] [98.236(n)(12)] | No |
Volume of gas sent to flare, Vs (standard cubic feet) [98.236(n)(4)] | 102807590 |
Flare combustion efficiency (decimal value) [98.236(n)(6)] | 0.98 |
Mole fraction of CH4 in flare feed gas, XCH4 [98.236(n)(7)] | 0.08299 |
Mole fraction of CO2 in flare feed gas, XCO2 [98.236(n)(8)] | 0.84366 |
Fraction of feed gas sent to un-lit flare, Zu [98.236(n)(5)] | 0 |
CO2 emissions (mt CO2) [98.236(n)(9)] | 5913.9926699 |
CH4 Emissions (mt CH4) (Eq. W-19) [98.236(n)(10)] | 3.2762887 |
N2O Emissions (mt N2O) (Eq. W-40) [98.236(n)(11)] | 0.0023574 |
Unique Name or ID Number for the Flare Stack [98.236(n)(1)] | PV-3008 |
Does the flare stack have a continuous flow monitor on gas to the flare? [98.236(n)(2)] | No |
Does the flare stack have a continuous gas analyzer on gas to the flare? [98.236(n)(3)] | No |
Were CEMS used to measure CO2 emissions for the flare stack? [98.233(n)(8)] [98.236(n)(12)] | No |
Volume of gas sent to flare, Vs (standard cubic feet) [98.236(n)(4)] | 65870 |
Flare combustion efficiency (decimal value) [98.236(n)(6)] | 0.98 |
Mole fraction of CH4 in flare feed gas, XCH4 [98.236(n)(7)] | 0.6242776 |
Mole fraction of CO2 in flare feed gas, XCO2 [98.236(n)(8)] | 0.2128 |
Fraction of feed gas sent to un-lit flare, Zu [98.236(n)(5)] | 0 |
CO2 emissions (mt CO2) [98.236(n)(9)] | 2.9978467 |
CH4 Emissions (mt CH4) (Eq. W-19) [98.236(n)(10)] | 0.0157905 |
N2O Emissions (mt N2O) (Eq. W-40) [98.236(n)(11)] | 0.0000044 |
Unique Name or ID Number for the Flare Stack [98.236(n)(1)] | PV-43B |
Does the flare stack have a continuous flow monitor on gas to the flare? [98.236(n)(2)] | No |
Does the flare stack have a continuous gas analyzer on gas to the flare? [98.236(n)(3)] | No |
Were CEMS used to measure CO2 emissions for the flare stack? [98.233(n)(8)] [98.236(n)(12)] | No |
Volume of gas sent to flare, Vs (standard cubic feet) [98.236(n)(4)] | 1236230 |
Flare combustion efficiency (decimal value) [98.236(n)(6)] | 0.98 |
Mole fraction of CH4 in flare feed gas, XCH4 [98.236(n)(7)] | 0.13212 |
Mole fraction of CO2 in flare feed gas, XCO2 [98.236(n)(8)] | 0.65495 |
Fraction of feed gas sent to un-lit flare, Zu [98.236(n)(5)] | 0 |
CO2 emissions (mt CO2) [98.236(n)(9)] | 90.7558985 |
CH4 Emissions (mt CH4) (Eq. W-19) [98.236(n)(10)] | 0.062719 |
N2O Emissions (mt N2O) (Eq. W-40) [98.236(n)(11)] | 0.0000824 |
Unique Name or ID Number for the Flare Stack [98.236(n)(1)] | PV-44B |
Does the flare stack have a continuous flow monitor on gas to the flare? [98.236(n)(2)] | No |
Does the flare stack have a continuous gas analyzer on gas to the flare? [98.236(n)(3)] | No |
Were CEMS used to measure CO2 emissions for the flare stack? [98.233(n)(8)] [98.236(n)(12)] | No |
Volume of gas sent to flare, Vs (standard cubic feet) [98.236(n)(4)] | 1769700 |
Flare combustion efficiency (decimal value) [98.236(n)(6)] | 0.98 |
Mole fraction of CH4 in flare feed gas, XCH4 [98.236(n)(7)] | 0.13212 |
Mole fraction of CO2 in flare feed gas, XCO2 [98.236(n)(8)] | 0.65495 |
Fraction of feed gas sent to un-lit flare, Zu [98.236(n)(5)] | 0 |
CO2 emissions (mt CO2) [98.236(n)(9)] | 129.919767 |
CH4 Emissions (mt CH4) (Eq. W-19) [98.236(n)(10)] | 0.0897841 |
N2O Emissions (mt N2O) (Eq. W-40) [98.236(n)(11)] | 0.0001179 |
Unique Name or ID Number for the Flare Stack [98.236(n)(1)] | PV-93B |
Does the flare stack have a continuous flow monitor on gas to the flare? [98.236(n)(2)] | No |
Does the flare stack have a continuous gas analyzer on gas to the flare? [98.236(n)(3)] | No |
Were CEMS used to measure CO2 emissions for the flare stack? [98.233(n)(8)] [98.236(n)(12)] | No |
Volume of gas sent to flare, Vs (standard cubic feet) [98.236(n)(4)] | 2857000 |
Flare combustion efficiency (decimal value) [98.236(n)(6)] | 0.98 |
Mole fraction of CH4 in flare feed gas, XCH4 [98.236(n)(7)] | 0.55783 |
Mole fraction of CO2 in flare feed gas, XCO2 [98.236(n)(8)] | 0.33154 |
Fraction of feed gas sent to un-lit flare, Zu [98.236(n)(5)] | 0 |
CO2 emissions (mt CO2) [98.236(n)(9)] | 142.6447587 |
CH4 Emissions (mt CH4) (Eq. W-19) [98.236(n)(10)] | 0.6119886 |
N2O Emissions (mt N2O) (Eq. W-40) [98.236(n)(11)] | 0.0001792 |
Unique Name or ID Number for the Flare Stack [98.236(n)(1)] | PV-96B |
Does the flare stack have a continuous flow monitor on gas to the flare? [98.236(n)(2)] | No |
Does the flare stack have a continuous gas analyzer on gas to the flare? [98.236(n)(3)] | No |
Were CEMS used to measure CO2 emissions for the flare stack? [98.233(n)(8)] [98.236(n)(12)] | No |
Volume of gas sent to flare, Vs (standard cubic feet) [98.236(n)(4)] | 315000 |
Flare combustion efficiency (decimal value) [98.236(n)(6)] | 0.98 |
Mole fraction of CH4 in flare feed gas, XCH4 [98.236(n)(7)] | 0.55783 |
Mole fraction of CO2 in flare feed gas, XCO2 [98.236(n)(8)] | 0.33154 |
Fraction of feed gas sent to un-lit flare, Zu [98.236(n)(5)] | 0 |
CO2 emissions (mt CO2) [98.236(n)(9)] | 15.7278581 |
CH4 Emissions (mt CH4) (Eq. W-19) [98.236(n)(10)] | 0.0674751 |
N2O Emissions (mt N2O) (Eq. W-40) [98.236(n)(11)] | 0.0000198 |
Unique Name or ID Number for the Flare Stack [98.236(n)(1)] | V-110 |
Does the flare stack have a continuous flow monitor on gas to the flare? [98.236(n)(2)] | No |
Does the flare stack have a continuous gas analyzer on gas to the flare? [98.236(n)(3)] | No |
Were CEMS used to measure CO2 emissions for the flare stack? [98.233(n)(8)] [98.236(n)(12)] | No |
Volume of gas sent to flare, Vs (standard cubic feet) [98.236(n)(4)] | 8100 |
Flare combustion efficiency (decimal value) [98.236(n)(6)] | 0.98 |
Mole fraction of CH4 in flare feed gas, XCH4 [98.236(n)(7)] | 0.1771 |
Mole fraction of CO2 in flare feed gas, XCO2 [98.236(n)(8)] | 0.6918 |
Fraction of feed gas sent to un-lit flare, Zu [98.236(n)(5)] | 0 |
CO2 emissions (mt CO2) [98.236(n)(9)] | 0.496169 |
CH4 Emissions (mt CH4) (Eq. W-19) [98.236(n)(10)] | 0.0005509 |
N2O Emissions (mt N2O) (Eq. W-40) [98.236(n)(11)] | 0.0000003 |
Unique Name or ID Number for the Flare Stack [98.236(n)(1)] | V-111 |
Does the flare stack have a continuous flow monitor on gas to the flare? [98.236(n)(2)] | No |
Does the flare stack have a continuous gas analyzer on gas to the flare? [98.236(n)(3)] | No |
Were CEMS used to measure CO2 emissions for the flare stack? [98.233(n)(8)] [98.236(n)(12)] | No |
Volume of gas sent to flare, Vs (standard cubic feet) [98.236(n)(4)] | 4003180 |
Flare combustion efficiency (decimal value) [98.236(n)(6)] | 0.98 |
Mole fraction of CH4 in flare feed gas, XCH4 [98.236(n)(7)] | 0.5933 |
Mole fraction of CO2 in flare feed gas, XCO2 [98.236(n)(8)] | 0.0119 |
Fraction of feed gas sent to un-lit flare, Zu [98.236(n)(5)] | 0 |
CO2 emissions (mt CO2) [98.236(n)(9)] | 292.2501015 |
CH4 Emissions (mt CH4) (Eq. W-19) [98.236(n)(10)] | 0.9120333 |
N2O Emissions (mt N2O) (Eq. W-40) [98.236(n)(11)] | 0.0004679 |
Unique Name or ID Number for the Flare Stack [98.236(n)(1)] | V-112 |
Does the flare stack have a continuous flow monitor on gas to the flare? [98.236(n)(2)] | No |
Does the flare stack have a continuous gas analyzer on gas to the flare? [98.236(n)(3)] | No |
Were CEMS used to measure CO2 emissions for the flare stack? [98.233(n)(8)] [98.236(n)(12)] | No |
Volume of gas sent to flare, Vs (standard cubic feet) [98.236(n)(4)] | 16003540 |
Flare combustion efficiency (decimal value) [98.236(n)(6)] | 0.98 |
Mole fraction of CH4 in flare feed gas, XCH4 [98.236(n)(7)] | 0.0746 |
Mole fraction of CO2 in flare feed gas, XCO2 [98.236(n)(8)] | 0.814 |
Fraction of feed gas sent to un-lit flare, Zu [98.236(n)(5)] | 0 |
CO2 emissions (mt CO2) [98.236(n)(9)] | 1028.3933697 |
CH4 Emissions (mt CH4) (Eq. W-19) [98.236(n)(10)] | 0.4584438 |
N2O Emissions (mt N2O) (Eq. W-40) [98.236(n)(11)] | 0.0005367 |
Unique Name or ID Number for the Flare Stack [98.236(n)(1)] | V-112B |
Does the flare stack have a continuous flow monitor on gas to the flare? [98.236(n)(2)] | No |
Does the flare stack have a continuous gas analyzer on gas to the flare? [98.236(n)(3)] | No |
Were CEMS used to measure CO2 emissions for the flare stack? [98.233(n)(8)] [98.236(n)(12)] | No |
Volume of gas sent to flare, Vs (standard cubic feet) [98.236(n)(4)] | 5196290 |
Flare combustion efficiency (decimal value) [98.236(n)(6)] | 0.98 |
Mole fraction of CH4 in flare feed gas, XCH4 [98.236(n)(7)] | 0.0746 |
Mole fraction of CO2 in flare feed gas, XCO2 [98.236(n)(8)] | 0.814 |
Fraction of feed gas sent to un-lit flare, Zu [98.236(n)(5)] | 0 |
CO2 emissions (mt CO2) [98.236(n)(9)] | 333.9155076 |
CH4 Emissions (mt CH4) (Eq. W-19) [98.236(n)(10)] | 0.148855 |
N2O Emissions (mt N2O) (Eq. W-40) [98.236(n)(11)] | 0.0001743 |
Unique Name or ID Number for the Flare Stack [98.236(n)(1)] | V-113 |
Does the flare stack have a continuous flow monitor on gas to the flare? [98.236(n)(2)] | No |
Does the flare stack have a continuous gas analyzer on gas to the flare? [98.236(n)(3)] | No |
Were CEMS used to measure CO2 emissions for the flare stack? [98.233(n)(8)] [98.236(n)(12)] | No |
Volume of gas sent to flare, Vs (standard cubic feet) [98.236(n)(4)] | 4861050 |
Flare combustion efficiency (decimal value) [98.236(n)(6)] | 0.98 |
Mole fraction of CH4 in flare feed gas, XCH4 [98.236(n)(7)] | 0.2243 |
Mole fraction of CO2 in flare feed gas, XCO2 [98.236(n)(8)] | 0.5353 |
Fraction of feed gas sent to un-lit flare, Zu [98.236(n)(5)] | 0 |
CO2 emissions (mt CO2) [98.236(n)(9)] | 356.8534196 |
CH4 Emissions (mt CH4) (Eq. W-19) [98.236(n)(10)] | 0.4186881 |
N2O Emissions (mt N2O) (Eq. W-40) [98.236(n)(11)] | 0.0003451 |
Unique name or ID for reciprocating compressor [98.236(p)(1)(i)] | K-1A Inlet/Demeth Compressor/637813 |
Total time in operating-mode (hours) [98.236(p)(1)(ii)] | 8108 |
Total time in standby-pressurized-mode (hours) [98.236(p)(1)(iii)] | 642 |
Total time in not-operating-depressurized-mode (hours) [98.236(p)(1)(iv)] | 10 |
Compressor measured in operating-mode? [98.236(p)(1)(v)] | Yes |
Compressor measured in standby-pressurized-mode? [98.236(p)(1)(vi)] | No |
Compressor measured in not-operating-depressurized-mode? [98.236(p)(1)(vii)] | No |
Compressor had blind flanges installed? [98.236(p)(1)(xii)] | No |
Power output of compressor driver (hp) [98.236(p)(1)(xiii)] | 3000 |
Compressor had scheduled depressurized shutdown during reporting year? [98.236(p)(1)(xiv)] | No |
Unique name or ID for reciprocating compressor [98.236(p)(1)(i)] | K-1B Inlet/Demeth Compressor/624990 |
Total time in operating-mode (hours) [98.236(p)(1)(ii)] | 8531 |
Total time in standby-pressurized-mode (hours) [98.236(p)(1)(iii)] | 31 |
Total time in not-operating-depressurized-mode (hours) [98.236(p)(1)(iv)] | 198 |
Compressor measured in operating-mode? [98.236(p)(1)(v)] | Yes |
Compressor measured in standby-pressurized-mode? [98.236(p)(1)(vi)] | No |
Compressor measured in not-operating-depressurized-mode? [98.236(p)(1)(vii)] | No |
Compressor had blind flanges installed? [98.236(p)(1)(xii)] | No |
Power output of compressor driver (hp) [98.236(p)(1)(xiii)] | 3000 |
Compressor had scheduled depressurized shutdown during reporting year? [98.236(p)(1)(xiv)] | No |
Unique name or ID for reciprocating compressor [98.236(p)(1)(i)] | K-1C Inlet/Demeth Compressor/634331 |
Total time in operating-mode (hours) [98.236(p)(1)(ii)] | 6755 |
Total time in standby-pressurized-mode (hours) [98.236(p)(1)(iii)] | 1450 |
Total time in not-operating-depressurized-mode (hours) [98.236(p)(1)(iv)] | 555 |
Compressor measured in operating-mode? [98.236(p)(1)(v)] | Yes |
Compressor measured in standby-pressurized-mode? [98.236(p)(1)(vi)] | No |
Compressor measured in not-operating-depressurized-mode? [98.236(p)(1)(vii)] | No |
Compressor had blind flanges installed? [98.236(p)(1)(xii)] | No |
Power output of compressor driver (hp) [98.236(p)(1)(xiii)] | 3000 |
Compressor had scheduled depressurized shutdown during reporting year? [98.236(p)(1)(xiv)] | No |
Unique name or ID for reciprocating compressor [98.236(p)(1)(i)] | K-1D Inlet/Demeth Compressor/625027 |
Total time in operating-mode (hours) [98.236(p)(1)(ii)] | 7116 |
Total time in standby-pressurized-mode (hours) [98.236(p)(1)(iii)] | 1571 |
Total time in not-operating-depressurized-mode (hours) [98.236(p)(1)(iv)] | 73 |
Compressor measured in operating-mode? [98.236(p)(1)(v)] | No |
Compressor measured in standby-pressurized-mode? [98.236(p)(1)(vi)] | Yes |
Compressor measured in not-operating-depressurized-mode? [98.236(p)(1)(vii)] | No |
Compressor had blind flanges installed? [98.236(p)(1)(xii)] | No |
Power output of compressor driver (hp) [98.236(p)(1)(xiii)] | 3000 |
Compressor had scheduled depressurized shutdown during reporting year? [98.236(p)(1)(xiv)] | No |
Unique name or ID for reciprocating compressor [98.236(p)(1)(i)] | K-4A Dehy. Regen Compressor/625031 |
Total time in operating-mode (hours) [98.236(p)(1)(ii)] | 8760 |
Total time in standby-pressurized-mode (hours) [98.236(p)(1)(iii)] | 0 |
Total time in not-operating-depressurized-mode (hours) [98.236(p)(1)(iv)] | 0 |
Compressor measured in operating-mode? [98.236(p)(1)(v)] | Yes |
Compressor measured in standby-pressurized-mode? [98.236(p)(1)(vi)] | No |
Compressor measured in not-operating-depressurized-mode? [98.236(p)(1)(vii)] | No |
Compressor had blind flanges installed? [98.236(p)(1)(xii)] | No |
Power output of compressor driver (hp) [98.236(p)(1)(xiii)] | 200 |
Compressor had scheduled depressurized shutdown during reporting year? [98.236(p)(1)(xiv)] | No |
Unique name or ID for reciprocating compressor [98.236(p)(1)(i)] | K-4B Dehy. Regen Compressor/638446 |
Total time in operating-mode (hours) [98.236(p)(1)(ii)] | 8760 |
Total time in standby-pressurized-mode (hours) [98.236(p)(1)(iii)] | 0 |
Total time in not-operating-depressurized-mode (hours) [98.236(p)(1)(iv)] | 0 |
Compressor measured in operating-mode? [98.236(p)(1)(v)] | Yes |
Compressor measured in standby-pressurized-mode? [98.236(p)(1)(vi)] | No |
Compressor measured in not-operating-depressurized-mode? [98.236(p)(1)(vii)] | No |
Compressor had blind flanges installed? [98.236(p)(1)(xii)] | No |
Power output of compressor driver (hp) [98.236(p)(1)(xiii)] | 200 |
Compressor had scheduled depressurized shutdown during reporting year? [98.236(p)(1)(xiv)] | No |
Unique name or ID for reciprocating compressor [98.236(p)(1)(i)] | K-5A Recycle CO2 Compressor/625032 |
Total time in operating-mode (hours) [98.236(p)(1)(ii)] | 8551 |
Total time in standby-pressurized-mode (hours) [98.236(p)(1)(iii)] | 0 |
Total time in not-operating-depressurized-mode (hours) [98.236(p)(1)(iv)] | 209 |
Compressor measured in operating-mode? [98.236(p)(1)(v)] | Yes |
Compressor measured in standby-pressurized-mode? [98.236(p)(1)(vi)] | No |
Compressor measured in not-operating-depressurized-mode? [98.236(p)(1)(vii)] | No |
Compressor had blind flanges installed? [98.236(p)(1)(xii)] | No |
Power output of compressor driver (hp) [98.236(p)(1)(xiii)] | 1000 |
Compressor had scheduled depressurized shutdown during reporting year? [98.236(p)(1)(xiv)] | No |
Unique name or ID for reciprocating compressor [98.236(p)(1)(i)] | K-5B Recycle CO2 Compressor/633637 |
Total time in operating-mode (hours) [98.236(p)(1)(ii)] | 8074 |
Total time in standby-pressurized-mode (hours) [98.236(p)(1)(iii)] | 0 |
Total time in not-operating-depressurized-mode (hours) [98.236(p)(1)(iv)] | 686 |
Compressor measured in operating-mode? [98.236(p)(1)(v)] | Yes |
Compressor measured in standby-pressurized-mode? [98.236(p)(1)(vi)] | No |
Compressor measured in not-operating-depressurized-mode? [98.236(p)(1)(vii)] | No |
Compressor had blind flanges installed? [98.236(p)(1)(xii)] | No |
Power output of compressor driver (hp) [98.236(p)(1)(xiii)] | 1000 |
Compressor had scheduled depressurized shutdown during reporting year? [98.236(p)(1)(xiv)] | No |
Unique name or ID for reciprocating compressor [98.236(p)(1)(i)] | K-5C Recycle CO2 Compressor/637334 |
Total time in operating-mode (hours) [98.236(p)(1)(ii)] | 8496 |
Total time in standby-pressurized-mode (hours) [98.236(p)(1)(iii)] | 151 |
Total time in not-operating-depressurized-mode (hours) [98.236(p)(1)(iv)] | 113 |
Compressor measured in operating-mode? [98.236(p)(1)(v)] | No |
Compressor measured in standby-pressurized-mode? [98.236(p)(1)(vi)] | Yes |
Compressor measured in not-operating-depressurized-mode? [98.236(p)(1)(vii)] | No |
Compressor had blind flanges installed? [98.236(p)(1)(xii)] | No |
Power output of compressor driver (hp) [98.236(p)(1)(xiii)] | 1000 |
Compressor had scheduled depressurized shutdown during reporting year? [98.236(p)(1)(xiv)] | No |
Unique name or ID for reciprocating compressor [98.236(p)(1)(i)] | K-9 Compressor |
Total time in operating-mode (hours) [98.236(p)(1)(ii)] | 8570 |
Total time in standby-pressurized-mode (hours) [98.236(p)(1)(iii)] | 0 |
Total time in not-operating-depressurized-mode (hours) [98.236(p)(1)(iv)] | 190 |
Compressor measured in operating-mode? [98.236(p)(1)(v)] | Yes |
Compressor measured in standby-pressurized-mode? [98.236(p)(1)(vi)] | No |
Compressor measured in not-operating-depressurized-mode? [98.236(p)(1)(vii)] | Yes |
Compressor had blind flanges installed? [98.236(p)(1)(xii)] | No |
Power output of compressor driver (hp) [98.236(p)(1)(xiii)] | 2250 |
Compressor had scheduled depressurized shutdown during reporting year? [98.236(p)(1)(xiv)] | Yes |
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)] | K-1A Inlet/Demeth Compressor/637813 |
Reciprocating compressor source [98.236(p)(2)(i)(B)] | Blowdown valve |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | K-1A Inlet/Demeth Compressor/637813_BD |
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)] | K-1A Inlet/Demeth Compressor/637813 |
Reciprocating compressor source [98.236(p)(2)(i)(B)] | Isolation valve |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | K-1A Inlet/Demeth Compressor/637813_IV |
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)] | K-1A Inlet/Demeth Compressor/637813 |
Reciprocating compressor source [98.236(p)(2)(i)(B)] | Rod packing |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | K-1A Inlet/Demeth Compressor/637813_RP |
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)] | K-1B Inlet/Demeth Compressor/624990 |
Reciprocating compressor source [98.236(p)(2)(i)(B)] | Blowdown valve |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | K-1B Inlet/Demeth Compressor/624990_BD |
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)] | K-1B Inlet/Demeth Compressor/624990 |
Reciprocating compressor source [98.236(p)(2)(i)(B)] | Isolation valve |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | K-1B Inlet/Demeth Compressor/624990_IV |
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)] | K-1B Inlet/Demeth Compressor/624990 |
Reciprocating compressor source [98.236(p)(2)(i)(B)] | Rod packing |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | K-1B Inlet/Demeth Compressor/624990_RP |
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)] | K-1C Inlet/Demeth Compressor/634331 |
Reciprocating compressor source [98.236(p)(2)(i)(B)] | Blowdown valve |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | K-1C Inlet/Demeth Compressor/634331_BD |
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)] | K-1C Inlet/Demeth Compressor/634331 |
Reciprocating compressor source [98.236(p)(2)(i)(B)] | Isolation valve |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | K-1C Inlet/Demeth Compressor/634331_IV |
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)] | K-1C Inlet/Demeth Compressor/634331 |
Reciprocating compressor source [98.236(p)(2)(i)(B)] | Rod packing |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | K-1C Inlet/Demeth Compressor/634331_RP |
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)] | K-1D Inlet/Demeth Compressor/625027 |
Reciprocating compressor source [98.236(p)(2)(i)(B)] | Blowdown valve |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | K-1D Inlet/Demeth Compressor/625027_BD |
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)] | K-1D Inlet/Demeth Compressor/625027 |
Reciprocating compressor source [98.236(p)(2)(i)(B)] | Isolation valve |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | K-1D Inlet/Demeth Compressor/625027_IV |
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)] | K-1D Inlet/Demeth Compressor/625027 |
Reciprocating compressor source [98.236(p)(2)(i)(B)] | Rod packing |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | K-1D Inlet/Demeth Compressor/625027_RP |
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)] | K-4A Dehy. Regen Compressor/625031 |
Reciprocating compressor source [98.236(p)(2)(i)(B)] | Blowdown valve |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | K-4A Dehy. Regen Compressor/625031_BD |
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)] | K-4A Dehy. Regen Compressor/625031 |
Reciprocating compressor source [98.236(p)(2)(i)(B)] | Isolation valve |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | K-4A Dehy. Regen Compressor/625031_IV |
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)] | K-4A Dehy. Regen Compressor/625031 |
Reciprocating compressor source [98.236(p)(2)(i)(B)] | Rod packing |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | K-4A Dehy. Regen Compressor/625031_RP |
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)] | K-4B Dehy. Regen Compressor/638446 |
Reciprocating compressor source [98.236(p)(2)(i)(B)] | Blowdown valve |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | K-4B Dehy. Regen Compressor/638446_BD |
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)] | K-4B Dehy. Regen Compressor/638446 |
Reciprocating compressor source [98.236(p)(2)(i)(B)] | Isolation valve |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | K-4B Dehy. Regen Compressor/638446_IV |
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)] | K-4B Dehy. Regen Compressor/638446 |
Reciprocating compressor source [98.236(p)(2)(i)(B)] | Rod packing |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | K-4B Dehy. Regen Compressor/638446_RP |
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)] | K-5A Recycle CO2 Compressor/625032 |
Reciprocating compressor source [98.236(p)(2)(i)(B)] | Blowdown valve |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | K-5A Recycle CO2 Compressor/625032_BD |
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)] | K-5A Recycle CO2 Compressor/625032 |
Reciprocating compressor source [98.236(p)(2)(i)(B)] | Isolation valve |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | K-5A Recycle CO2 Compressor/625032_IV |
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)] | K-5A Recycle CO2 Compressor/625032 |
Reciprocating compressor source [98.236(p)(2)(i)(B)] | Rod packing |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | K-5A Recycle CO2 Compressor/625032_RP |
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)] | K-5B Recycle CO2 Compressor/633637 |
Reciprocating compressor source [98.236(p)(2)(i)(B)] | Blowdown valve |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | K-5B Recycle CO2 Compressor/633637_BD |
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)] | K-5B Recycle CO2 Compressor/633637 |
Reciprocating compressor source [98.236(p)(2)(i)(B)] | Isolation valve |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | K-5B Recycle CO2 Compressor/633637_IV |
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)] | K-5B Recycle CO2 Compressor/633637 |
Reciprocating compressor source [98.236(p)(2)(i)(B)] | Rod packing |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | K-5B Recycle CO2 Compressor/633637_RP |
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)] | K-5C Recycle CO2 Compressor/637334 |
Reciprocating compressor source [98.236(p)(2)(i)(B)] | Blowdown valve |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | K-5C Recycle CO2 Compressor/637334_BD |
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)] | K-5C Recycle CO2 Compressor/637334 |
Reciprocating compressor source [98.236(p)(2)(i)(B)] | Isolation valve |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | K-5C Recycle CO2 Compressor/637334_IV |
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)] | K-5C Recycle CO2 Compressor/637334 |
Reciprocating compressor source [98.236(p)(2)(i)(B)] | Rod packing |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | K-5C Recycle CO2 Compressor/637334_RP |
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)] | K-9 Compressor |
Reciprocating compressor source [98.236(p)(2)(i)(B)] | Blowdown valve |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | K-9 Compressor_BD |
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)] | K-9 Compressor |
Reciprocating compressor source [98.236(p)(2)(i)(B)] | Isolation valve |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | K-9 Compressor_IV |
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)] | K-9 Compressor |
Reciprocating compressor source [98.236(p)(2)(i)(B)] | Rod packing |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | K-9 Compressor_RP |
Unique Name or ID for leak or vent (Specify) [98.236(p)(2)(i)(C)] [98.236(p)(3)(i)(A)] | K-1A Inlet/Demeth Compressor/637813_RP |
Measurement date (mm/dd/yyyy) [98.236(p)(3)(i)(B)] | 2022-12-07 |
Measurement method [98.236(p)(3)(i)(C)] | Screening/Optical gas imaging |
Measured flow rate (standard cubic feet/hour) [98.236(p)(3)(i)(D)] | 0 |
Is the measurement location prior to or after commingling with non-compressor emission sources? [98.236(p)(3)(i)(F)] | Not manifolded |
Compressors in “Operating mode” | K-1A Inlet/Demeth Compressor/637813_RP |
Unique Name or ID for leak or vent (Specify) [98.236(p)(2)(i)(C)] [98.236(p)(3)(i)(A)] | K-1B Inlet/Demeth Compressor/624990_RP |
Measurement date (mm/dd/yyyy) [98.236(p)(3)(i)(B)] | 2022-12-07 |
Measurement method [98.236(p)(3)(i)(C)] | Screening/Optical gas imaging |
Measured flow rate (standard cubic feet/hour) [98.236(p)(3)(i)(D)] | 0 |
Is the measurement location prior to or after commingling with non-compressor emission sources? [98.236(p)(3)(i)(F)] | Not manifolded |
Compressors in “Operating mode” | K-1B Inlet/Demeth Compressor/624990_RP |
Unique Name or ID for leak or vent (Specify) [98.236(p)(2)(i)(C)] [98.236(p)(3)(i)(A)] | K-1C Inlet/Demeth Compressor/634331_RP |
Measurement date (mm/dd/yyyy) [98.236(p)(3)(i)(B)] | 2022-12-07 |
Measurement method [98.236(p)(3)(i)(C)] | Screening/Optical gas imaging |
Measured flow rate (standard cubic feet/hour) [98.236(p)(3)(i)(D)] | 0 |
Is the measurement location prior to or after commingling with non-compressor emission sources? [98.236(p)(3)(i)(F)] | Not manifolded |
Compressors in “Operating mode” | K-1C Inlet/Demeth Compressor/634331_RP |
Unique Name or ID for leak or vent (Specify) [98.236(p)(2)(i)(C)] [98.236(p)(3)(i)(A)] | K-4A Dehy. Regen Compressor/625031_BD |
Measurement date (mm/dd/yyyy) [98.236(p)(3)(i)(B)] | 2022-12-07 |
Measurement method [98.236(p)(3)(i)(C)] | Screening/Optical gas imaging |
Measured flow rate (standard cubic feet/hour) [98.236(p)(3)(i)(D)] | 0 |
Is the measurement location prior to or after commingling with non-compressor emission sources? [98.236(p)(3)(i)(F)] | Not manifolded |
Compressors in “Operating mode” | K-4A Dehy. Regen Compressor/625031_BD |
Unique Name or ID for leak or vent (Specify) [98.236(p)(2)(i)(C)] [98.236(p)(3)(i)(A)] | K-4A Dehy. Regen Compressor/625031_RP |
Measurement date (mm/dd/yyyy) [98.236(p)(3)(i)(B)] | 2022-12-07 |
Measurement method [98.236(p)(3)(i)(C)] | Screening/Optical gas imaging |
Measured flow rate (standard cubic feet/hour) [98.236(p)(3)(i)(D)] | 0 |
Is the measurement location prior to or after commingling with non-compressor emission sources? [98.236(p)(3)(i)(F)] | Not manifolded |
Compressors in “Operating mode” | K-4A Dehy. Regen Compressor/625031_RP |
Unique Name or ID for leak or vent (Specify) [98.236(p)(2)(i)(C)] [98.236(p)(3)(i)(A)] | K-4B Dehy. Regen Compressor/638446_BD |
Measurement date (mm/dd/yyyy) [98.236(p)(3)(i)(B)] | 2022-12-07 |
Measurement method [98.236(p)(3)(i)(C)] | High volume sampler |
Measured flow rate (standard cubic feet/hour) [98.236(p)(3)(i)(D)] | 16.318 |
Is the measurement location prior to or after commingling with non-compressor emission sources? [98.236(p)(3)(i)(F)] | Not manifolded |
Compressors in “Operating mode” | K-4B Dehy. Regen Compressor/638446_BD |
Unique Name or ID for leak or vent (Specify) [98.236(p)(2)(i)(C)] [98.236(p)(3)(i)(A)] | K-4B Dehy. Regen Compressor/638446_RP |
Measurement date (mm/dd/yyyy) [98.236(p)(3)(i)(B)] | 2022-12-07 |
Measurement method [98.236(p)(3)(i)(C)] | High volume sampler |
Measured flow rate (standard cubic feet/hour) [98.236(p)(3)(i)(D)] | 29.789 |
Is the measurement location prior to or after commingling with non-compressor emission sources? [98.236(p)(3)(i)(F)] | Not manifolded |
Compressors in “Operating mode” | K-4B Dehy. Regen Compressor/638446_RP |
Unique Name or ID for leak or vent (Specify) [98.236(p)(2)(i)(C)] [98.236(p)(3)(i)(A)] | K-5A Recycle CO2 Compressor/625032_RP |
Measurement date (mm/dd/yyyy) [98.236(p)(3)(i)(B)] | 2022-12-07 |
Measurement method [98.236(p)(3)(i)(C)] | Screening/Optical gas imaging |
Measured flow rate (standard cubic feet/hour) [98.236(p)(3)(i)(D)] | 0 |
Is the measurement location prior to or after commingling with non-compressor emission sources? [98.236(p)(3)(i)(F)] | Not manifolded |
Compressors in “Operating mode” | K-5A Recycle CO2 Compressor/625032_RP |
Unique Name or ID for leak or vent (Specify) [98.236(p)(2)(i)(C)] [98.236(p)(3)(i)(A)] | K-5B Recycle CO2 Compressor/633637_RP |
Measurement date (mm/dd/yyyy) [98.236(p)(3)(i)(B)] | 2022-12-07 |
Measurement method [98.236(p)(3)(i)(C)] | Screening/Optical gas imaging |
Measured flow rate (standard cubic feet/hour) [98.236(p)(3)(i)(D)] | 0 |
Is the measurement location prior to or after commingling with non-compressor emission sources? [98.236(p)(3)(i)(F)] | Not manifolded |
Compressors in “Operating mode” | K-5B Recycle CO2 Compressor/633637_RP |
Unique Name or ID for leak or vent (Specify) [98.236(p)(2)(i)(C)] [98.236(p)(3)(i)(A)] | K-9 Compressor_BD |
Measurement date (mm/dd/yyyy) [98.236(p)(3)(i)(B)] | 2022-12-07 |
Measurement method [98.236(p)(3)(i)(C)] | Acoustic leak detection |
Measured flow rate (standard cubic feet/hour) [98.236(p)(3)(i)(D)] | 0 |
Is the measurement location prior to or after commingling with non-compressor emission sources? [98.236(p)(3)(i)(F)] | Not manifolded |
Compressors in “Operating mode” | K-9 Compressor_BD |
Unique Name or ID for leak or vent (Specify) [98.236(p)(2)(i)(C)] [98.236(p)(3)(i)(A)] | K-9 Compressor_RP |
Measurement date (mm/dd/yyyy) [98.236(p)(3)(i)(B)] | 2022-12-07 |
Measurement method [98.236(p)(3)(i)(C)] | High volume sampler |
Measured flow rate (standard cubic feet/hour) [98.236(p)(3)(i)(D)] | 21.945 |
Is the measurement location prior to or after commingling with non-compressor emission sources? [98.236(p)(3)(i)(F)] | Not manifolded |
Compressors in “Operating mode” | K-9 Compressor_RP |
Unique Name or ID for leak or vent (Specify) [98.236(p)(2)(i)(C)] [98.236(p)(3)(i)(A)] | K-9 Compressor_IV |
Measurement date (mm/dd/yyyy) [98.236(p)(3)(i)(B)] | 2022-04-08 |
Measurement method [98.236(p)(3)(i)(C)] | Acoustic leak detection |
Measured flow rate (standard cubic feet/hour) [98.236(p)(3)(i)(D)] | 0 |
Is the measurement location prior to or after commingling with non-compressor emission sources? [98.236(p)(3)(i)(F)] | Not manifolded |
Compressors in “Not-operating mode” | K-9 Compressor_IV |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | K-1A Inlet/Demeth Compressor/637813_BD |
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)] | Single |
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)] | Flare |
Percentage of time the device was operational when compressor source emissions were routed to device [98.236(p)(2)(ii)(E)] | 0.5 |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | K-1A Inlet/Demeth Compressor/637813_IV |
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)] | Single |
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)] | Atmosphere |
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)] | No |
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)] | No |
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)] | 0.0107433 |
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)] | 0.0002834 |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | K-1A Inlet/Demeth Compressor/637813_RP |
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)] | Single |
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)] | Atmosphere |
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)] | Yes |
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)] | No |
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)] | 0 |
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)] | 0 |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | K-1B Inlet/Demeth Compressor/624990_BD |
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)] | Single |
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)] | Flare |
Percentage of time the device was operational when compressor source emissions were routed to device [98.236(p)(2)(ii)(E)] | 0.5 |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | K-1B Inlet/Demeth Compressor/624990_IV |
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)] | Single |
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)] | Atmosphere |
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)] | No |
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)] | No |
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)] | 0.2127178 |
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)] | 0.0056108 |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | K-1B Inlet/Demeth Compressor/624990_RP |
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)] | Single |
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)] | Atmosphere |
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)] | Yes |
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)] | No |
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)] | 0 |
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)] | 0 |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | K-1C Inlet/Demeth Compressor/634331_BD |
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)] | Single |
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)] | Flare |
Percentage of time the device was operational when compressor source emissions were routed to device [98.236(p)(2)(ii)(E)] | 0.5 |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | K-1C Inlet/Demeth Compressor/634331_IV |
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)] | Single |
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)] | Atmosphere |
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)] | No |
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)] | No |
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)] | 0.5962545 |
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)] | 0.0157272 |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | K-1C Inlet/Demeth Compressor/634331_RP |
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)] | Single |
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)] | Atmosphere |
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)] | Yes |
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)] | No |
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)] | 0 |
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)] | 0 |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | K-1D Inlet/Demeth Compressor/625027_BD |
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)] | Single |
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)] | Flare |
Percentage of time the device was operational when compressor source emissions were routed to device [98.236(p)(2)(ii)(E)] | 0.5 |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | K-1D Inlet/Demeth Compressor/625027_IV |
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)] | Single |
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)] | Atmosphere |
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)] | No |
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)] | No |
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)] | 0.0784263 |
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)] | 0.0020686 |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | K-1D Inlet/Demeth Compressor/625027_RP |
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)] | Single |
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)] | Atmosphere |
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)] | No |
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)] | No |
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)] | 16.77635 |
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)] | 0.4425053 |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | K-4A Dehy. Regen Compressor/625031_BD |
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)] | Single |
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)] | Atmosphere |
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)] | Yes |
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)] | No |
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)] | 0 |
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)] | 0 |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | K-4A Dehy. Regen Compressor/625031_IV |
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)] | Single |
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)] | Atmosphere |
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)] | No |
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)] | No |
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)] | 0 |
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)] | 0 |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | K-4A Dehy. Regen Compressor/625031_RP |
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)] | Single |
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)] | Atmosphere |
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)] | Yes |
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)] | No |
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)] | 0 |
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)] | 0 |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | K-4B Dehy. Regen Compressor/638446_BD |
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)] | Single |
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)] | Atmosphere |
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)] | Yes |
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)] | No |
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)] | 6.6023016 |
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)] | 0.1741471 |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | K-4B Dehy. Regen Compressor/638446_IV |
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)] | Single |
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)] | Atmosphere |
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)] | No |
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)] | No |
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)] | 0 |
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)] | 0 |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | K-4B Dehy. Regen Compressor/638446_RP |
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)] | Single |
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)] | Atmosphere |
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)] | Yes |
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)] | No |
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)] | 12.0527003 |
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)] | 0.3179108 |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | K-5A Recycle CO2 Compressor/625032_BD |
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)] | Single |
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)] | Flare |
Percentage of time the device was operational when compressor source emissions were routed to device [98.236(p)(2)(ii)(E)] | 1 |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | K-5A Recycle CO2 Compressor/625032_IV |
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)] | Single |
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)] | Atmosphere |
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)] | No |
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)] | No |
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)] | 0.2245355 |
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)] | 0.0059225 |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | K-5A Recycle CO2 Compressor/625032_RP |
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)] | Single |
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)] | Atmosphere |
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)] | Yes |
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)] | No |
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)] | 0 |
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)] | 0 |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | K-5B Recycle CO2 Compressor/633637_BD |
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)] | Single |
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)] | Flare |
Percentage of time the device was operational when compressor source emissions were routed to device [98.236(p)(2)(ii)(E)] | 1 |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | K-5B Recycle CO2 Compressor/633637_IV |
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)] | Single |
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)] | Atmosphere |
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)] | No |
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)] | No |
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)] | 0.7369921 |
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)] | 0.0194394 |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | K-5B Recycle CO2 Compressor/633637_RP |
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)] | Single |
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)] | Atmosphere |
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)] | Yes |
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)] | No |
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)] | 0 |
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)] | 0 |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | K-5C Recycle CO2 Compressor/637334_BD |
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)] | Single |
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)] | Flare |
Percentage of time the device was operational when compressor source emissions were routed to device [98.236(p)(2)(ii)(E)] | 1 |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | K-5C Recycle CO2 Compressor/637334_IV |
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)] | Single |
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)] | Atmosphere |
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)] | No |
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)] | No |
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)] | 0.1213996 |
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)] | 0.0032021 |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | K-5C Recycle CO2 Compressor/637334_RP |
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)] | Single |
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)] | Atmosphere |
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)] | No |
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)] | No |
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)] | 0.3559906 |
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)] | 0.0093899 |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | K-9 Compressor_BD |
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)] | Single |
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)] | Atmosphere |
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)] | Yes |
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)] | No |
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)] | 0 |
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)] | 0 |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | K-9 Compressor_IV |
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)] | Single |
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)] | Atmosphere |
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)] | Yes |
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)] | No |
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)] | 0 |
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)] | 0 |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | K-9 Compressor_RP |
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)] | Single |
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)] | Atmosphere |
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)] | Yes |
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)] | No |
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)] | 8.6864182 |
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)] | 0.2291193 |
Component Type [98.236(q)(2)(i)] | Compressor Components, Gas Service - Valve |
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)] | 18 |
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)] | 8760 |
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)] | 108.0773875 |
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)] | 2.8507282 |
Component Type [98.236(q)(2)(i)] | Compressor Components, Gas Service - Connector |
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)] | 19 |
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)] | 8760 |
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)] | 42.9728187 |
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)] | 1.1334825 |
Component Type [98.236(q)(2)(i)] | Compressor Components, Gas Service - Open-ended Line |
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)] | 1 |
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)] | 8760 |
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)] | 6.9874831 |
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)] | 0.184307 |
Component Type [98.236(q)(2)(i)] | Compressor Components, Gas Service - Pressure Relief Valve |
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)] | 0 |
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)] | 0 |
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)] | 0 |
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)] | 0 |
Component Type [98.236(q)(2)(i)] | Compressor Components, Gas Service - Meter |
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)] | 0 |
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)] | 0 |
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)] | 0 |
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)] | 0 |
Component Type [98.236(q)(2)(i)] | Non-Compressor Components, Gas Service - Valve |
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)] | 17 |
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)] | 8760 |
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)] | 44.1583036 |
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)] | 1.1647517 |
Component Type [98.236(q)(2)(i)] | Non-Compressor Components, Gas Service - Connector |
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)] | 1 |
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)] | 8760 |
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)] | 2.3102796 |
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)] | 0.0609376 |
Component Type [98.236(q)(2)(i)] | Non-Compressor Components, Gas Service - Open-ended Line |
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)] | 0 |
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)] | 0 |
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)] | 0 |
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)] | 0 |
Component Type [98.236(q)(2)(i)] | Non-Compressor components, Gas Service - Pressure Relief Valve |
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)] | 0 |
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)] | 0 |
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)] | 0 |
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)] | 0 |
Component Type [98.236(q)(2)(i)] | Non-Compressor components, Gas Service - Meter |
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)] | 0 |
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)] | 0 |
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)] | 0 |
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)] | 0 |