Facility Name:DENVER UNIT CO 2 RECOVERY PLANT
Facility Identifier:
Facility Reporting Year:2022
Facility Location:
Address: 1.5 M N OF DENVER CITY ON SH 214
City: DENVER CITY
State: TX
Postal Code: 79323

Facility Site Details:
CO2 equivalent emissions from facility subparts C-II, SS, and TT (metric tons):178,660.9
CO2 equivalent emissions from supplier subparts LL-QQ (metric tons):
Biogenic CO2 emissions from facility subparts C-II, SS, and TT (metric tons):0
Cogeneration Unit Emissions Indicator:N
GHG Report Start Date:2022-01-01
GHG Report End Date:2022-12-31
Description of Changes to Calculation Methodology:
Plant Code Indicator:N
Primary NAICS Code:211120
Second Primary NAICS Code:

Parent Company Details:
Parent Company Name:COTERRA ENERGY INC
Address:840 Gessner Road, Suite 1400, Houston,  TX 77024
Percent Ownership Interest:1
Parent Company Name:EXXON MOBIL CORP
Address:5959 Las Colinas Blvd, Irving,  TX 75039
Percent Ownership Interest:12
Parent Company Name:OCCIDENTAL PETROLEUM CORP
Address:5 Greenway Plaza, Suite 110, Houston,  TX 77046
Percent Ownership Interest:53
Parent Company Name:CHEVRON CORP
Address:6001 Bollinger Canyon Road, San Ramon,  CA 94583
Percent Ownership Interest:17
Parent Company Name:ARIEL EXPLORATION INC
Address:500 N Akard St Ste 1900, Dallas,  TX 75201
Percent Ownership Interest:1
Parent Company Name:DEVON ENERGY CORP
Address:333 West Sheridan Avenue, Oklahoma City,  OK 73102
Percent Ownership Interest:1
Parent Company Name:EXXON MOBIL CORP
Address:5959 Las Colinas Blvd, Irving,  TX 75039
Percent Ownership Interest:12
Parent Company Name:CONOCOPHILLIPS
Address:925 N Eldridge Pkwy, Houston,  TX 77079
Percent Ownership Interest:14

Subpart C: General Stationary Fuel Combustion

Gas Information Details

Gas NameCarbon Dioxide
Gas Quantity76,514.3 (Metric Tons)
Own Result?

Gas NameBiogenic Carbon dioxide
Gas Quantity0 (Metric Tons)
Own Result?

Gas NameMethane
Gas Quantity1.44 (Metric Tons)
Own Result?

Gas NameNitrous Oxide
Gas Quantity0.144 (Metric Tons)
Own Result?

Unit Details:
Unit Name : GP- Denver Unit CO2 Recovery Plant
Unit Type : OCS (Other combustion source)
Unit Description :
Other Unit Name :
Small Unit Aggregation Details:
Use Ivt Indicator: Y
Highest Maximum Rated Heat Input Capacity: 123
Cumulative Maximum Rated Heat Input Capacity: 235

Emission Details:
Annual CO2 mass emissions from sorbent: 0 (Metric Tons)
Annual Biogenic CO2 Emissions: 0 (metric tons)
Annual Fossil fuel based CO2 Emissions: 76514.2 (metric tons)

Tier Fuel Details:
Fuel : Natural Gas (Weighted U.S. Average)
Tier Name : Tier 2 (Equation C-2a)
Tier Methodology Start Date : 2022-01-01
Tier Methodology End Date : 2022-12-31
Frequency of HHV determinations : Semiannually

Tier 2 Monthly HHV Details :
JanuaryFebruaryMarchAprilMayJuneJulyAugustSeptemberOctoberNovemberDecember
Y N N N N N Y N N N N N

Fuel Emission Details :
Total CO2 emissionsTotal CH4 emissionsTotal N2O emissionsTotal CH4 emissions CO2eTotal N2O emissions CO2e
76508.2 (Metric Tons) 1.44 (Metric Tons) 0.144 (Metric Tons) 36 (Metric Tons) 43 (Metric Tons)


Fuel : Distillate Fuel Oil No. 2
Tier Name : Tier 1 (Equation C-1)
Tier Methodology Start Date : 2022-01-01
Tier Methodology End Date : 2022-12-31

Fuel Emission Details :
Total CO2 emissionsTotal CH4 emissionsTotal N2O emissionsTotal CH4 emissions CO2eTotal N2O emissions CO2e
6.1 (Metric Tons) 0.00 (Metric Tons) 0.000 (Metric Tons) 0 (Metric Tons) 0 (Metric Tons)



Subpart W: Petroleum and Natural Gas Systems

Gas Information Details

Gas NameCarbon Dioxide
Gas Quantity31,170.6 (Metric Tons)
Own Result?

Gas NameMethane
Gas Quantity2,835.79 (Metric Tons)
Own Result?

Gas NameNitrous Oxide
Gas Quantity0.008 (Metric Tons)
Own Result?


SubpartWSummaryDetails:
Industry Segment Number3
Industry Segment NameOnshore natural gas processing [98.230(a)(3)]
Total Reported CO2 Emissions (mt CO2)31170.6
Total CO2e Emissions (mt CO2e)102067.7
Total Reported CH4 Emissions (mt CH4)2835.79
Total Reported N2O Emissions (mt N2O)0.008


SubpartWSourceReportingFormRowDetails:
Source Reporting FormOnshore Production [98.236(aa)(1)]
Required for Selected Industry SegmentNo
Source Reporting FormFacility Overview [98.236(aa)(2-11)]
Required for Selected Industry SegmentYes
Source Reporting FormNatural Gas Pneumatic Devices [98.236(b)]
Required for Selected Industry SegmentNo
Total Reported CO2 Emissions (mt CO2)0.0
Total Reported CH4 Emissions (mt CH4)0.00
Source Reporting FormNatural Gas Driven Pneumatic Pumps [98.236(c)]
Required for Selected Industry SegmentNo
Total Reported CO2 Emissions (mt CO2)0.0
Total Reported CH4 Emissions (mt CH4)0.00
Source Reporting FormAcid Gas Removal Units [98.236(d)]
Required for Selected Industry SegmentYes
Total Reported CO2 Emissions (mt CO2)16919.0
Source Reporting FormDehydrators [98.236(e)]
Required for Selected Industry SegmentYes
Total Reported CO2 Emissions (mt CO2)0.0
Total Reported CH4 Emissions (mt CH4)0.00
Total Reported N2O Emissions (mt N2O)0.000
Source Reporting FormWell Venting for Liquids Unloading [98.236(f)]
Required for Selected Industry SegmentNo
Total Reported CO2 Emissions (mt CO2)0.0
Total Reported CH4 Emissions (mt CH4)0.00
Source Reporting FormCompletions and Workovers with Hydraulic Fracturing [98.236(g)]
Required for Selected Industry SegmentNo
Total Reported CO2 Emissions (mt CO2)0.0
Total Reported CH4 Emissions (mt CH4)0.00
Total Reported N2O Emissions (mt N2O)0.000
Source Reporting FormCompletions and Workovers without Hydraulic Fracturing [98.236(h)]
Required for Selected Industry SegmentNo
Total Reported CO2 Emissions (mt CO2)0.0
Total Reported CH4 Emissions (mt CH4)0.00
Total Reported N2O Emissions (mt N2O)0.000
Source Reporting FormBlowdown Vent Stacks [98.236(i)]
Required for Selected Industry SegmentYes
Total Reported CO2 Emissions (mt CO2)4.1
Total Reported CH4 Emissions (mt CH4)2816.31
Source Reporting FormAtmospheric Storage Tanks [98.236(j)]
Required for Selected Industry SegmentNo
Total Reported CO2 Emissions (mt CO2)0.0
Total Reported CH4 Emissions (mt CH4)0.00
Total Reported N2O Emissions (mt N2O)0.000
Source Reporting FormTransmission Storage Tanks [98.236(k)]
Required for Selected Industry SegmentNo
Total Reported CO2 Emissions (mt CO2)0.0
Total Reported CH4 Emissions (mt CH4)0.00
Total Reported N2O Emissions (mt N2O)0.000
Source Reporting FormWell Testing [98.236(l)]
Required for Selected Industry SegmentNo
Total Reported CO2 Emissions (mt CO2)0.0
Total Reported CH4 Emissions (mt CH4)0.00
Total Reported N2O Emissions (mt N2O)0.000
Source Reporting FormAssociated Gas Venting and Flaring [98.236(m)]
Required for Selected Industry SegmentNo
Total Reported CO2 Emissions (mt CO2)0.0
Total Reported CH4 Emissions (mt CH4)0.00
Total Reported N2O Emissions (mt N2O)0.000
Source Reporting FormFlare Stacks [98.236(n)]
Required for Selected Industry SegmentYes
Total Reported CO2 Emissions (mt CO2)13996.6
Total Reported CH4 Emissions (mt CH4)12.86
Total Reported N2O Emissions (mt N2O)0.008
Source Reporting FormCentrifugal Compressors [98.236(o)]
Required for Selected Industry SegmentYes
Total Reported CO2 Emissions (mt CO2)0.0
Total Reported CH4 Emissions (mt CH4)0.00
Source Reporting FormReciprocating Compressors [98.236(p)]
Required for Selected Industry SegmentYes
Total Reported CO2 Emissions (mt CO2)46.5
Total Reported CH4 Emissions (mt CH4)1.23
Source Reporting FormEquipment Leaks Surveys and Population Counts [98.236(q,r)]
Required for Selected Industry SegmentYes
Total Reported CO2 Emissions (mt CO2)204.5
Total Reported CH4 Emissions (mt CH4)5.39
Source Reporting FormOffshore Petroleum and Natural Gas Production [98.236(s)]
Required for Selected Industry SegmentNo
Total Reported CO2 Emissions (mt CO2)0.0
Total Reported CH4 Emissions (mt CH4)0.00
Total Reported N2O Emissions (mt N2O)0.000
Source Reporting FormEnhanced Oil Recovery Injection Pumps [98.236(w)]
Required for Selected Industry SegmentNo
Total Reported CO2 Emissions (mt CO2)0.0
Source Reporting FormEnhanced Oil Recovery Hydrocarbon Liquids [98.236(x)]
Required for Selected Industry SegmentNo
Total Reported CO2 Emissions (mt CO2)0.0
Source Reporting FormCombustion Equipment at Onshore Petroleum and Natural Gas Production Facilities, Onshore Petroleum and Natural Gas Gathering and Boosting Facilities, and Natural gas Distribution Facilities [98.236(z)]
Required for Selected Industry SegmentNo
Total Reported CO2 Emissions (mt CO2)0.0
Total Reported CH4 Emissions (mt CH4)0.00
Total Reported N2O Emissions (mt N2O)0.000


FacilityOverviewDetails:


FacilityOverviewNaturalGasProcessingRowDetails:
Average mole fraction of CH4 in natural gas received [98.236(aa)(3)(v)]0.0634518
Average mole fraction of CO2 in natural gas received [98.236(aa)(3)(vi)]0.8780891
Does the facility fractionate NGLs? [98.236(aa)(3)(vii)]No


AcidGasRemovalUnitsDetails:
mt CO216919.0
Did the Facility have any acid gas removal units that vent directly to the atmosphere, to a flare or engine, or to a sulfur recovery plant subject to reporting under 98.232 [98.236(d)]?Yes
Were missing data procedures used for any parameters to calculate GHG emissions? [98.235]Yes


AcidMissingAcidDataProcUsedRowDetails:
Unit ID or Name [98.236(d)(1)(i)]Amine Unit (AGR-1)
Calculation Method 1 emissions [Table D.2]Annual volume of gas vented from the acid gas removal unit
Measurement FrequencyAnnually
Procedures used [98.235(h)]Used an estimated maximum provided by the facility process engineer.


AcidGasInfoRowDetails:
Unit ID or Name [98.236(d)(1)(i)]Amine Unit (AGR-1)
Total feed rate entering the acid gas removal unit for the year (million cubic feet) [98.236(d)(1)(ii)]8719.85
Calculation Method Used (Select from list) [98.236(d)(1)(iii)]Calculation Methodology 3 [98.233(d)(3)]
Are any CO2 emissions from the acid gas removal unit recovered and transferred outside the facility? (Yes / No) [98.236(d)(1)(iv)]Yes
Total CO2 Emissions (mt CO2) [98.236(d)(1)(v)]16918.957056


AcidGasCalcMethod3EmissionsRowDetails:
Unit ID or Name [98.236(d)(1)(i)]Amine Unit (AGR-1)
Equation Used (W-4A/W-4B) [98.236(d)(2)(ii)(A)]W-4A
Annual average fraction of CO2 content of natural gas into the acid gas removal unit, Voli (volumetric fraction) [98.236(d)(2)(ii)(C)]0.8780891
Annual average fraction of CO2 content of natural gas out of the acid gas removal unit, Volo (volumetric fraction) [98.236(d)(2)(ii)(B)]0.0070455
Natural gas flow rate into the acid gas removal unit, Vin (actual or standard cubic feet) (Eq. W-4A) [98.236(d)(2)(ii)(D)]8719850000
Natural gas flow rate reported on an Actual or Standard basis? [98.236]Standard
Temperature used to calculate natural gas flow rate (°F) [98.236]60
Pressure used to calculate natural gas flow rate (psi) [98.236]14.7


DehydratorsDetails:
mt CO20.0
mt CH40.00
mt N2O0.000
Did the facility have any glycol dehydrators with annual average daily natural gas throughputs greater than or equal to 0.4MMscfd subject to reporting under 98.232 [98.236(e)]?No
Did the facility have any glycol dehydrators with annual average daily natural gas throughputs less than 0.4MMscfd subject to reporting under 98.232 [98.236(e)]?No
Did the facility have any desiccant dehydrators subject to reporting under 98.232 [98.236(e)]?Yes
Were missing data procedures used for any parameters to calculate GHG emissions? [98.235]No


SmallGlycolDehydrators:
Emissions vented to flare or regenerator firebox/fire tubes
Emissions that were not vented to a flare or regenerator firebox/fire tubes


DessicantDehydrators:
Total Number of Desiccant Dehydrators [98.236(e)(3)(i)]7
Vapor RecoveryYes
Number of Desiccant Dehydrators By Vent Control Type, Count [98.236(e)(3)(i)]7
Dehydrator vents to flares or regenerator firebox/fire tubesNo
Control devices other than vapor recovery, flare or regenerator firebox/fire tubesNo
Emissions vented to flare or regenerator firebox/fire tubes
Emissions that were not vented to a flare or regenerator firebox/fire tubes
Total CO2 Emissions (mt CO2) [98.236(e)(3)(i)] [98.236(e)(3)(ii)]0
Total CH4 Emissions (mt CH4) [98.236(e)(3)(i)] [98.236(e)(3)(iii)]0


BlowdownVentStacksDetails:
mt CO24.1
mt CH42816.31
Did the facility have any blowdown vent stacks subject to reporting under 98.232 [98.236(i)]?Yes
Were missing data procedures used for any parameters to calculate GHG emissions? [98.235]No
How were emissions determined? [98.236(i)]Using flow meters


BlowdownVentStacksEmissionsRowDetails:
Annual total CO2 emissions calculated by flow meter (mt CO2) [98.236(i)(2)(i)]4.0916709
Annual total CH4 emissions calculated by flow meter (mt CH4) [98.236(i)(2)(ii)]2816.3058217


FlareStacksDetails:
mt CO213996.6
mt CH412.86
mt N2O0.008
Did the facility have flare stacks subject to reporting under 98.232 [98.236(n)]?Yes
Were missing data procedures used for any parameters to calculate GHG emissions? [98.235]No


UniqueFlareStacksRowDetails:
Unique Name or ID Number for the Flare Stack [98.236(n)(1)]FL1/GAS FLARING
Does the flare stack have a continuous flow monitor on gas to the flare? [98.236(n)(2)]No
Does the flare stack have a continuous gas analyzer on gas to the flare? [98.236(n)(3)]No
Were CEMS used to measure CO2 emissions for the flare stack? [98.233(n)(8)] [98.236(n)(12)]No
Volume of gas sent to flare, Vs (standard cubic feet) [98.236(n)(4)]3118110
Flare combustion efficiency (decimal value) [98.236(n)(6)]0.98
Mole fraction of CH4 in flare feed gas, XCH4 [98.236(n)(7)]0.01198
Mole fraction of CO2 in flare feed gas, XCO2 [98.236(n)(8)]0.53055
Fraction of feed gas sent to un-lit flare, Zu [98.236(n)(5)]0
CO2 emissions (mt CO2) [98.236(n)(9)]374.116973
CH4 Emissions (mt CH4) (Eq. W-19) [98.236(n)(10)]0.0143443
N2O Emissions (mt N2O) (Eq. W-40) [98.236(n)(11)]0.0004339
Unique Name or ID Number for the Flare Stack [98.236(n)(1)]PV-109B
Does the flare stack have a continuous flow monitor on gas to the flare? [98.236(n)(2)]No
Does the flare stack have a continuous gas analyzer on gas to the flare? [98.236(n)(3)]No
Were CEMS used to measure CO2 emissions for the flare stack? [98.233(n)(8)] [98.236(n)(12)]No
Volume of gas sent to flare, Vs (standard cubic feet) [98.236(n)(4)]583000
Flare combustion efficiency (decimal value) [98.236(n)(6)]0.98
Mole fraction of CH4 in flare feed gas, XCH4 [98.236(n)(7)]0.78265
Mole fraction of CO2 in flare feed gas, XCO2 [98.236(n)(8)]0.02551
Fraction of feed gas sent to un-lit flare, Zu [98.236(n)(5)]0
CO2 emissions (mt CO2) [98.236(n)(9)]24.7776904
CH4 Emissions (mt CH4) (Eq. W-19) [98.236(n)(10)]0.1752134
N2O Emissions (mt N2O) (Eq. W-40) [98.236(n)(11)]0.0000474
Unique Name or ID Number for the Flare Stack [98.236(n)(1)]PV-109B2
Does the flare stack have a continuous flow monitor on gas to the flare? [98.236(n)(2)]No
Does the flare stack have a continuous gas analyzer on gas to the flare? [98.236(n)(3)]No
Were CEMS used to measure CO2 emissions for the flare stack? [98.233(n)(8)] [98.236(n)(12)]No
Volume of gas sent to flare, Vs (standard cubic feet) [98.236(n)(4)]514370
Flare combustion efficiency (decimal value) [98.236(n)(6)]0.98
Mole fraction of CH4 in flare feed gas, XCH4 [98.236(n)(7)]0.78265
Mole fraction of CO2 in flare feed gas, XCO2 [98.236(n)(8)]0.02551
Fraction of feed gas sent to un-lit flare, Zu [98.236(n)(5)]0
CO2 emissions (mt CO2) [98.236(n)(9)]21.860893
CH4 Emissions (mt CH4) (Eq. W-19) [98.236(n)(10)]0.1545875
N2O Emissions (mt N2O) (Eq. W-40) [98.236(n)(11)]0.0000422
Unique Name or ID Number for the Flare Stack [98.236(n)(1)]PV-1101B
Does the flare stack have a continuous flow monitor on gas to the flare? [98.236(n)(2)]No
Does the flare stack have a continuous gas analyzer on gas to the flare? [98.236(n)(3)]No
Were CEMS used to measure CO2 emissions for the flare stack? [98.233(n)(8)] [98.236(n)(12)]No
Volume of gas sent to flare, Vs (standard cubic feet) [98.236(n)(4)]12239610
Flare combustion efficiency (decimal value) [98.236(n)(6)]0.98
Mole fraction of CH4 in flare feed gas, XCH4 [98.236(n)(7)]0.81142
Mole fraction of CO2 in flare feed gas, XCO2 [98.236(n)(8)]0.00009
Fraction of feed gas sent to un-lit flare, Zu [98.236(n)(5)]0
CO2 emissions (mt CO2) [98.236(n)(9)]520.9768543
CH4 Emissions (mt CH4) (Eq. W-19) [98.236(n)(10)]3.8136823
N2O Emissions (mt N2O) (Eq. W-40) [98.236(n)(11)]0.001061
Unique Name or ID Number for the Flare Stack [98.236(n)(1)]PV-111
Does the flare stack have a continuous flow monitor on gas to the flare? [98.236(n)(2)]No
Does the flare stack have a continuous gas analyzer on gas to the flare? [98.236(n)(3)]No
Were CEMS used to measure CO2 emissions for the flare stack? [98.233(n)(8)] [98.236(n)(12)]No
Volume of gas sent to flare, Vs (standard cubic feet) [98.236(n)(4)]45850
Flare combustion efficiency (decimal value) [98.236(n)(6)]0.98
Mole fraction of CH4 in flare feed gas, XCH4 [98.236(n)(7)]0.71082
Mole fraction of CO2 in flare feed gas, XCO2 [98.236(n)(8)]0.18987
Fraction of feed gas sent to un-lit flare, Zu [98.236(n)(5)]0
CO2 emissions (mt CO2) [98.236(n)(9)]2.1853049
CH4 Emissions (mt CH4) (Eq. W-19) [98.236(n)(10)]0.012515
N2O Emissions (mt N2O) (Eq. W-40) [98.236(n)(11)]0.0000033
Unique Name or ID Number for the Flare Stack [98.236(n)(1)]PV-12
Does the flare stack have a continuous flow monitor on gas to the flare? [98.236(n)(2)]No
Does the flare stack have a continuous gas analyzer on gas to the flare? [98.236(n)(3)]No
Were CEMS used to measure CO2 emissions for the flare stack? [98.233(n)(8)] [98.236(n)(12)]No
Volume of gas sent to flare, Vs (standard cubic feet) [98.236(n)(4)]82481530
Flare combustion efficiency (decimal value) [98.236(n)(6)]0.98
Mole fraction of CH4 in flare feed gas, XCH4 [98.236(n)(7)]0.08299
Mole fraction of CO2 in flare feed gas, XCO2 [98.236(n)(8)]0.84366
Fraction of feed gas sent to un-lit flare, Zu [98.236(n)(5)]0
CO2 emissions (mt CO2) [98.236(n)(9)]4744.7388255
CH4 Emissions (mt CH4) (Eq. W-19) [98.236(n)(10)]2.6285346
N2O Emissions (mt N2O) (Eq. W-40) [98.236(n)(11)]0.0018913
Unique Name or ID Number for the Flare Stack [98.236(n)(1)]PV-121B
Does the flare stack have a continuous flow monitor on gas to the flare? [98.236(n)(2)]No
Does the flare stack have a continuous gas analyzer on gas to the flare? [98.236(n)(3)]No
Were CEMS used to measure CO2 emissions for the flare stack? [98.233(n)(8)] [98.236(n)(12)]No
Volume of gas sent to flare, Vs (standard cubic feet) [98.236(n)(4)]738570
Flare combustion efficiency (decimal value) [98.236(n)(6)]0.98
Mole fraction of CH4 in flare feed gas, XCH4 [98.236(n)(7)]0
Mole fraction of CO2 in flare feed gas, XCO2 [98.236(n)(8)]0
Fraction of feed gas sent to un-lit flare, Zu [98.236(n)(5)]0
CO2 emissions (mt CO2) [98.236(n)(9)]0
CH4 Emissions (mt CH4) (Eq. W-19) [98.236(n)(10)]0
N2O Emissions (mt N2O) (Eq. W-40) [98.236(n)(11)]0.0001809
Unique Name or ID Number for the Flare Stack [98.236(n)(1)]PV-12B
Does the flare stack have a continuous flow monitor on gas to the flare? [98.236(n)(2)]No
Does the flare stack have a continuous gas analyzer on gas to the flare? [98.236(n)(3)]No
Were CEMS used to measure CO2 emissions for the flare stack? [98.233(n)(8)] [98.236(n)(12)]No
Volume of gas sent to flare, Vs (standard cubic feet) [98.236(n)(4)]102807590
Flare combustion efficiency (decimal value) [98.236(n)(6)]0.98
Mole fraction of CH4 in flare feed gas, XCH4 [98.236(n)(7)]0.08299
Mole fraction of CO2 in flare feed gas, XCO2 [98.236(n)(8)]0.84366
Fraction of feed gas sent to un-lit flare, Zu [98.236(n)(5)]0
CO2 emissions (mt CO2) [98.236(n)(9)]5913.9926699
CH4 Emissions (mt CH4) (Eq. W-19) [98.236(n)(10)]3.2762887
N2O Emissions (mt N2O) (Eq. W-40) [98.236(n)(11)]0.0023574
Unique Name or ID Number for the Flare Stack [98.236(n)(1)]PV-3008
Does the flare stack have a continuous flow monitor on gas to the flare? [98.236(n)(2)]No
Does the flare stack have a continuous gas analyzer on gas to the flare? [98.236(n)(3)]No
Were CEMS used to measure CO2 emissions for the flare stack? [98.233(n)(8)] [98.236(n)(12)]No
Volume of gas sent to flare, Vs (standard cubic feet) [98.236(n)(4)]65870
Flare combustion efficiency (decimal value) [98.236(n)(6)]0.98
Mole fraction of CH4 in flare feed gas, XCH4 [98.236(n)(7)]0.6242776
Mole fraction of CO2 in flare feed gas, XCO2 [98.236(n)(8)]0.2128
Fraction of feed gas sent to un-lit flare, Zu [98.236(n)(5)]0
CO2 emissions (mt CO2) [98.236(n)(9)]2.9978467
CH4 Emissions (mt CH4) (Eq. W-19) [98.236(n)(10)]0.0157905
N2O Emissions (mt N2O) (Eq. W-40) [98.236(n)(11)]0.0000044
Unique Name or ID Number for the Flare Stack [98.236(n)(1)]PV-43B
Does the flare stack have a continuous flow monitor on gas to the flare? [98.236(n)(2)]No
Does the flare stack have a continuous gas analyzer on gas to the flare? [98.236(n)(3)]No
Were CEMS used to measure CO2 emissions for the flare stack? [98.233(n)(8)] [98.236(n)(12)]No
Volume of gas sent to flare, Vs (standard cubic feet) [98.236(n)(4)]1236230
Flare combustion efficiency (decimal value) [98.236(n)(6)]0.98
Mole fraction of CH4 in flare feed gas, XCH4 [98.236(n)(7)]0.13212
Mole fraction of CO2 in flare feed gas, XCO2 [98.236(n)(8)]0.65495
Fraction of feed gas sent to un-lit flare, Zu [98.236(n)(5)]0
CO2 emissions (mt CO2) [98.236(n)(9)]90.7558985
CH4 Emissions (mt CH4) (Eq. W-19) [98.236(n)(10)]0.062719
N2O Emissions (mt N2O) (Eq. W-40) [98.236(n)(11)]0.0000824
Unique Name or ID Number for the Flare Stack [98.236(n)(1)]PV-44B
Does the flare stack have a continuous flow monitor on gas to the flare? [98.236(n)(2)]No
Does the flare stack have a continuous gas analyzer on gas to the flare? [98.236(n)(3)]No
Were CEMS used to measure CO2 emissions for the flare stack? [98.233(n)(8)] [98.236(n)(12)]No
Volume of gas sent to flare, Vs (standard cubic feet) [98.236(n)(4)]1769700
Flare combustion efficiency (decimal value) [98.236(n)(6)]0.98
Mole fraction of CH4 in flare feed gas, XCH4 [98.236(n)(7)]0.13212
Mole fraction of CO2 in flare feed gas, XCO2 [98.236(n)(8)]0.65495
Fraction of feed gas sent to un-lit flare, Zu [98.236(n)(5)]0
CO2 emissions (mt CO2) [98.236(n)(9)]129.919767
CH4 Emissions (mt CH4) (Eq. W-19) [98.236(n)(10)]0.0897841
N2O Emissions (mt N2O) (Eq. W-40) [98.236(n)(11)]0.0001179
Unique Name or ID Number for the Flare Stack [98.236(n)(1)]PV-93B
Does the flare stack have a continuous flow monitor on gas to the flare? [98.236(n)(2)]No
Does the flare stack have a continuous gas analyzer on gas to the flare? [98.236(n)(3)]No
Were CEMS used to measure CO2 emissions for the flare stack? [98.233(n)(8)] [98.236(n)(12)]No
Volume of gas sent to flare, Vs (standard cubic feet) [98.236(n)(4)]2857000
Flare combustion efficiency (decimal value) [98.236(n)(6)]0.98
Mole fraction of CH4 in flare feed gas, XCH4 [98.236(n)(7)]0.55783
Mole fraction of CO2 in flare feed gas, XCO2 [98.236(n)(8)]0.33154
Fraction of feed gas sent to un-lit flare, Zu [98.236(n)(5)]0
CO2 emissions (mt CO2) [98.236(n)(9)]142.6447587
CH4 Emissions (mt CH4) (Eq. W-19) [98.236(n)(10)]0.6119886
N2O Emissions (mt N2O) (Eq. W-40) [98.236(n)(11)]0.0001792
Unique Name or ID Number for the Flare Stack [98.236(n)(1)]PV-96B
Does the flare stack have a continuous flow monitor on gas to the flare? [98.236(n)(2)]No
Does the flare stack have a continuous gas analyzer on gas to the flare? [98.236(n)(3)]No
Were CEMS used to measure CO2 emissions for the flare stack? [98.233(n)(8)] [98.236(n)(12)]No
Volume of gas sent to flare, Vs (standard cubic feet) [98.236(n)(4)]315000
Flare combustion efficiency (decimal value) [98.236(n)(6)]0.98
Mole fraction of CH4 in flare feed gas, XCH4 [98.236(n)(7)]0.55783
Mole fraction of CO2 in flare feed gas, XCO2 [98.236(n)(8)]0.33154
Fraction of feed gas sent to un-lit flare, Zu [98.236(n)(5)]0
CO2 emissions (mt CO2) [98.236(n)(9)]15.7278581
CH4 Emissions (mt CH4) (Eq. W-19) [98.236(n)(10)]0.0674751
N2O Emissions (mt N2O) (Eq. W-40) [98.236(n)(11)]0.0000198
Unique Name or ID Number for the Flare Stack [98.236(n)(1)]V-110
Does the flare stack have a continuous flow monitor on gas to the flare? [98.236(n)(2)]No
Does the flare stack have a continuous gas analyzer on gas to the flare? [98.236(n)(3)]No
Were CEMS used to measure CO2 emissions for the flare stack? [98.233(n)(8)] [98.236(n)(12)]No
Volume of gas sent to flare, Vs (standard cubic feet) [98.236(n)(4)]8100
Flare combustion efficiency (decimal value) [98.236(n)(6)]0.98
Mole fraction of CH4 in flare feed gas, XCH4 [98.236(n)(7)]0.1771
Mole fraction of CO2 in flare feed gas, XCO2 [98.236(n)(8)]0.6918
Fraction of feed gas sent to un-lit flare, Zu [98.236(n)(5)]0
CO2 emissions (mt CO2) [98.236(n)(9)]0.496169
CH4 Emissions (mt CH4) (Eq. W-19) [98.236(n)(10)]0.0005509
N2O Emissions (mt N2O) (Eq. W-40) [98.236(n)(11)]0.0000003
Unique Name or ID Number for the Flare Stack [98.236(n)(1)]V-111
Does the flare stack have a continuous flow monitor on gas to the flare? [98.236(n)(2)]No
Does the flare stack have a continuous gas analyzer on gas to the flare? [98.236(n)(3)]No
Were CEMS used to measure CO2 emissions for the flare stack? [98.233(n)(8)] [98.236(n)(12)]No
Volume of gas sent to flare, Vs (standard cubic feet) [98.236(n)(4)]4003180
Flare combustion efficiency (decimal value) [98.236(n)(6)]0.98
Mole fraction of CH4 in flare feed gas, XCH4 [98.236(n)(7)]0.5933
Mole fraction of CO2 in flare feed gas, XCO2 [98.236(n)(8)]0.0119
Fraction of feed gas sent to un-lit flare, Zu [98.236(n)(5)]0
CO2 emissions (mt CO2) [98.236(n)(9)]292.2501015
CH4 Emissions (mt CH4) (Eq. W-19) [98.236(n)(10)]0.9120333
N2O Emissions (mt N2O) (Eq. W-40) [98.236(n)(11)]0.0004679
Unique Name or ID Number for the Flare Stack [98.236(n)(1)]V-112
Does the flare stack have a continuous flow monitor on gas to the flare? [98.236(n)(2)]No
Does the flare stack have a continuous gas analyzer on gas to the flare? [98.236(n)(3)]No
Were CEMS used to measure CO2 emissions for the flare stack? [98.233(n)(8)] [98.236(n)(12)]No
Volume of gas sent to flare, Vs (standard cubic feet) [98.236(n)(4)]16003540
Flare combustion efficiency (decimal value) [98.236(n)(6)]0.98
Mole fraction of CH4 in flare feed gas, XCH4 [98.236(n)(7)]0.0746
Mole fraction of CO2 in flare feed gas, XCO2 [98.236(n)(8)]0.814
Fraction of feed gas sent to un-lit flare, Zu [98.236(n)(5)]0
CO2 emissions (mt CO2) [98.236(n)(9)]1028.3933697
CH4 Emissions (mt CH4) (Eq. W-19) [98.236(n)(10)]0.4584438
N2O Emissions (mt N2O) (Eq. W-40) [98.236(n)(11)]0.0005367
Unique Name or ID Number for the Flare Stack [98.236(n)(1)]V-112B
Does the flare stack have a continuous flow monitor on gas to the flare? [98.236(n)(2)]No
Does the flare stack have a continuous gas analyzer on gas to the flare? [98.236(n)(3)]No
Were CEMS used to measure CO2 emissions for the flare stack? [98.233(n)(8)] [98.236(n)(12)]No
Volume of gas sent to flare, Vs (standard cubic feet) [98.236(n)(4)]5196290
Flare combustion efficiency (decimal value) [98.236(n)(6)]0.98
Mole fraction of CH4 in flare feed gas, XCH4 [98.236(n)(7)]0.0746
Mole fraction of CO2 in flare feed gas, XCO2 [98.236(n)(8)]0.814
Fraction of feed gas sent to un-lit flare, Zu [98.236(n)(5)]0
CO2 emissions (mt CO2) [98.236(n)(9)]333.9155076
CH4 Emissions (mt CH4) (Eq. W-19) [98.236(n)(10)]0.148855
N2O Emissions (mt N2O) (Eq. W-40) [98.236(n)(11)]0.0001743
Unique Name or ID Number for the Flare Stack [98.236(n)(1)]V-113
Does the flare stack have a continuous flow monitor on gas to the flare? [98.236(n)(2)]No
Does the flare stack have a continuous gas analyzer on gas to the flare? [98.236(n)(3)]No
Were CEMS used to measure CO2 emissions for the flare stack? [98.233(n)(8)] [98.236(n)(12)]No
Volume of gas sent to flare, Vs (standard cubic feet) [98.236(n)(4)]4861050
Flare combustion efficiency (decimal value) [98.236(n)(6)]0.98
Mole fraction of CH4 in flare feed gas, XCH4 [98.236(n)(7)]0.2243
Mole fraction of CO2 in flare feed gas, XCO2 [98.236(n)(8)]0.5353
Fraction of feed gas sent to un-lit flare, Zu [98.236(n)(5)]0
CO2 emissions (mt CO2) [98.236(n)(9)]356.8534196
CH4 Emissions (mt CH4) (Eq. W-19) [98.236(n)(10)]0.4186881
N2O Emissions (mt N2O) (Eq. W-40) [98.236(n)(11)]0.0003451


CentrifugalCompressorsDetails:
mt CO20.0
mt CH40.00
Did the facility have any centrifugal compressors subject to reporting under 98.232 [98.236(o)]?Yes
Were missing data procedures used for any parameters to calculate GHG emissions? [98.235]No


CentrifugalCompressorsActivityDataRowDetails:
Compressor ID or Unique Name [98.236(o)(1)(i)]K-1E Inlet/Demeth Compressor/625028
Total time in operating-mode (hours) [98.236(o)(1)(ii)]8705
Total time in not-operating-depressurized-mode (hours) [98.236(o)(1)(iii)]34
Compressor measured in operating-mode? [98.236(o)(1)(iv)]Yes
Compressor measured in not-operating-depressurized-mode? [98.236(o)(1)(v)]No
Compressor had blind flanges installed? [98.236(o)(1)(x)]No
Seal Type (wet or dry) [98.236(o)(1)(xi)]Dry
Power output of compressor driver (hp) [98.236(o)(1)(xiii)]3000
Compressor had scheduled depressurized shutdown during reporting year? [98.236(o)(1)(xiv)]No


CentrifugalCompressorsCompressorSourceRowDetails:
Unique Compressor Name or ID [98.236(o)(2)(i)(A)]K-1E Inlet/Demeth Compressor/625028
Centrifugal compressor source [98.236(o)(2)(i)(B)]Blowdown valve
Unique Name or ID for leak or vent [98.236(o)(2)(i)(C)]K-1E Inlet/Demeth Compressor/625028_BD
Unique Compressor Name or ID [98.236(o)(2)(i)(A)]K-1E Inlet/Demeth Compressor/625028
Centrifugal compressor source [98.236(o)(2)(i)(B)]Isolation valve
Unique Name or ID for leak or vent [98.236(o)(2)(i)(C)]K-1E Inlet/Demeth Compressor/625028_IV
Unique Compressor Name or ID [98.236(o)(2)(i)(A)]K-1E Inlet/Demeth Compressor/625028
Centrifugal compressor source [98.236(o)(2)(i)(B)]Wet seal


CentrifugalCompressorsEmissionFactorsSampleDataRowDetails:
Compressor Mode [98.236(o)(3)(ii)(A)]Operating
Compressor Source [98.236(o)(3)(ii)(A)]Wet seal
Compressor mode-source combination reporter emission factor, EFs,m (standard cubic feet per hour) [98.236(o)(3)(ii)(B)]0
Total number of compressors measured in the compressor mode-source combination in current reporting year and preceding two reporting years [98.236(o)(3)(ii)(C)]0
Is the reporter emission factor facility-specific or based on all of the reporter's applicable facilities? [98.236(o)(3)(ii)(D)]Facility-specific
Compressor Mode [98.236(o)(3)(ii)(A)]Operating
Compressor Source [98.236(o)(3)(ii)(A)]Blowdown valve
Compressor mode-source combination reporter emission factor, EFs,m (standard cubic feet per hour) [98.236(o)(3)(ii)(B)]0
Total number of compressors measured in the compressor mode-source combination in current reporting year and preceding two reporting years [98.236(o)(3)(ii)(C)]3
Is the reporter emission factor facility-specific or based on all of the reporter's applicable facilities? [98.236(o)(3)(ii)(D)]Facility-specific
Compressor Mode [98.236(o)(3)(ii)(A)]Not-operating
Compressor Source [98.236(o)(3)(ii)(A)]Isolation valve
Compressor mode-source combination reporter emission factor, EFs,m (standard cubic feet per hour) [98.236(o)(3)(ii)(B)]0
Total number of compressors measured in the compressor mode-source combination in current reporting year and preceding two reporting years [98.236(o)(3)(ii)(C)]0
Is the reporter emission factor facility-specific or based on all of the reporter's applicable facilities? [98.236(o)(3)(ii)(D)]Facility-specific


CentrifugalCompressorsLeakOrVentDataRowDetails:
Unique Name or ID for leak or vent [98.236(o)(2)(i)(C)]K-1E Inlet/Demeth Compressor/625028_BD
Leak or vent for a single compressor source or a manifolded group? [98.236(o)(2)(ii)(A)] [98.236(o)(1)(vi)]Single
Where are leak or vent emissions released? [98.236(o)(2)(ii)(A)] [98.236(o)(1)(vii) through (ix)]Flare
Percentage of time the device was operational when compressor source emissions were routed to device [98.236(o)(2)(ii)(E)]1
Unique Name or ID for leak or vent [98.236(o)(2)(i)(C)]K-1E Inlet/Demeth Compressor/625028_IV
Leak or vent for a single compressor source or a manifolded group? [98.236(o)(2)(ii)(A)] [98.236(o)(1)(vi)]Single
Where are leak or vent emissions released? [98.236(o)(2)(ii)(A)] [98.236(o)(1)(vii) through (ix)]Flare
Percentage of time the device was operational when compressor source emissions were routed to device [98.236(o)(2)(ii)(E)]1


ReciprocatingCompressorsDetails:
mt CO246.5
mt CH41.23
Did the facility have any reciprocating compressors subject to reporting under 98.232 [98.236(p)]?Yes
Were missing data procedures used for any parameters to calculate GHG emissions? [98.235]No


ReciprocatingCompressorsActivityDataRowDetails:
Unique name or ID for reciprocating compressor [98.236(p)(1)(i)]K-1A Inlet/Demeth Compressor/637813
Total time in operating-mode (hours) [98.236(p)(1)(ii)]8108
Total time in standby-pressurized-mode (hours) [98.236(p)(1)(iii)]642
Total time in not-operating-depressurized-mode (hours) [98.236(p)(1)(iv)]10
Compressor measured in operating-mode? [98.236(p)(1)(v)]Yes
Compressor measured in standby-pressurized-mode? [98.236(p)(1)(vi)]No
Compressor measured in not-operating-depressurized-mode? [98.236(p)(1)(vii)]No
Compressor had blind flanges installed? [98.236(p)(1)(xii)]No
Power output of compressor driver (hp) [98.236(p)(1)(xiii)]3000
Compressor had scheduled depressurized shutdown during reporting year? [98.236(p)(1)(xiv)]No
Unique name or ID for reciprocating compressor [98.236(p)(1)(i)]K-1B Inlet/Demeth Compressor/624990
Total time in operating-mode (hours) [98.236(p)(1)(ii)]8531
Total time in standby-pressurized-mode (hours) [98.236(p)(1)(iii)]31
Total time in not-operating-depressurized-mode (hours) [98.236(p)(1)(iv)]198
Compressor measured in operating-mode? [98.236(p)(1)(v)]Yes
Compressor measured in standby-pressurized-mode? [98.236(p)(1)(vi)]No
Compressor measured in not-operating-depressurized-mode? [98.236(p)(1)(vii)]No
Compressor had blind flanges installed? [98.236(p)(1)(xii)]No
Power output of compressor driver (hp) [98.236(p)(1)(xiii)]3000
Compressor had scheduled depressurized shutdown during reporting year? [98.236(p)(1)(xiv)]No
Unique name or ID for reciprocating compressor [98.236(p)(1)(i)]K-1C Inlet/Demeth Compressor/634331
Total time in operating-mode (hours) [98.236(p)(1)(ii)]6755
Total time in standby-pressurized-mode (hours) [98.236(p)(1)(iii)]1450
Total time in not-operating-depressurized-mode (hours) [98.236(p)(1)(iv)]555
Compressor measured in operating-mode? [98.236(p)(1)(v)]Yes
Compressor measured in standby-pressurized-mode? [98.236(p)(1)(vi)]No
Compressor measured in not-operating-depressurized-mode? [98.236(p)(1)(vii)]No
Compressor had blind flanges installed? [98.236(p)(1)(xii)]No
Power output of compressor driver (hp) [98.236(p)(1)(xiii)]3000
Compressor had scheduled depressurized shutdown during reporting year? [98.236(p)(1)(xiv)]No
Unique name or ID for reciprocating compressor [98.236(p)(1)(i)]K-1D Inlet/Demeth Compressor/625027
Total time in operating-mode (hours) [98.236(p)(1)(ii)]7116
Total time in standby-pressurized-mode (hours) [98.236(p)(1)(iii)]1571
Total time in not-operating-depressurized-mode (hours) [98.236(p)(1)(iv)]73
Compressor measured in operating-mode? [98.236(p)(1)(v)]No
Compressor measured in standby-pressurized-mode? [98.236(p)(1)(vi)]Yes
Compressor measured in not-operating-depressurized-mode? [98.236(p)(1)(vii)]No
Compressor had blind flanges installed? [98.236(p)(1)(xii)]No
Power output of compressor driver (hp) [98.236(p)(1)(xiii)]3000
Compressor had scheduled depressurized shutdown during reporting year? [98.236(p)(1)(xiv)]No
Unique name or ID for reciprocating compressor [98.236(p)(1)(i)]K-4A Dehy. Regen Compressor/625031
Total time in operating-mode (hours) [98.236(p)(1)(ii)]8760
Total time in standby-pressurized-mode (hours) [98.236(p)(1)(iii)]0
Total time in not-operating-depressurized-mode (hours) [98.236(p)(1)(iv)]0
Compressor measured in operating-mode? [98.236(p)(1)(v)]Yes
Compressor measured in standby-pressurized-mode? [98.236(p)(1)(vi)]No
Compressor measured in not-operating-depressurized-mode? [98.236(p)(1)(vii)]No
Compressor had blind flanges installed? [98.236(p)(1)(xii)]No
Power output of compressor driver (hp) [98.236(p)(1)(xiii)]200
Compressor had scheduled depressurized shutdown during reporting year? [98.236(p)(1)(xiv)]No
Unique name or ID for reciprocating compressor [98.236(p)(1)(i)]K-4B Dehy. Regen Compressor/638446
Total time in operating-mode (hours) [98.236(p)(1)(ii)]8760
Total time in standby-pressurized-mode (hours) [98.236(p)(1)(iii)]0
Total time in not-operating-depressurized-mode (hours) [98.236(p)(1)(iv)]0
Compressor measured in operating-mode? [98.236(p)(1)(v)]Yes
Compressor measured in standby-pressurized-mode? [98.236(p)(1)(vi)]No
Compressor measured in not-operating-depressurized-mode? [98.236(p)(1)(vii)]No
Compressor had blind flanges installed? [98.236(p)(1)(xii)]No
Power output of compressor driver (hp) [98.236(p)(1)(xiii)]200
Compressor had scheduled depressurized shutdown during reporting year? [98.236(p)(1)(xiv)]No
Unique name or ID for reciprocating compressor [98.236(p)(1)(i)]K-5A Recycle CO2 Compressor/625032
Total time in operating-mode (hours) [98.236(p)(1)(ii)]8551
Total time in standby-pressurized-mode (hours) [98.236(p)(1)(iii)]0
Total time in not-operating-depressurized-mode (hours) [98.236(p)(1)(iv)]209
Compressor measured in operating-mode? [98.236(p)(1)(v)]Yes
Compressor measured in standby-pressurized-mode? [98.236(p)(1)(vi)]No
Compressor measured in not-operating-depressurized-mode? [98.236(p)(1)(vii)]No
Compressor had blind flanges installed? [98.236(p)(1)(xii)]No
Power output of compressor driver (hp) [98.236(p)(1)(xiii)]1000
Compressor had scheduled depressurized shutdown during reporting year? [98.236(p)(1)(xiv)]No
Unique name or ID for reciprocating compressor [98.236(p)(1)(i)]K-5B Recycle CO2 Compressor/633637
Total time in operating-mode (hours) [98.236(p)(1)(ii)]8074
Total time in standby-pressurized-mode (hours) [98.236(p)(1)(iii)]0
Total time in not-operating-depressurized-mode (hours) [98.236(p)(1)(iv)]686
Compressor measured in operating-mode? [98.236(p)(1)(v)]Yes
Compressor measured in standby-pressurized-mode? [98.236(p)(1)(vi)]No
Compressor measured in not-operating-depressurized-mode? [98.236(p)(1)(vii)]No
Compressor had blind flanges installed? [98.236(p)(1)(xii)]No
Power output of compressor driver (hp) [98.236(p)(1)(xiii)]1000
Compressor had scheduled depressurized shutdown during reporting year? [98.236(p)(1)(xiv)]No
Unique name or ID for reciprocating compressor [98.236(p)(1)(i)]K-5C Recycle CO2 Compressor/637334
Total time in operating-mode (hours) [98.236(p)(1)(ii)]8496
Total time in standby-pressurized-mode (hours) [98.236(p)(1)(iii)]151
Total time in not-operating-depressurized-mode (hours) [98.236(p)(1)(iv)]113
Compressor measured in operating-mode? [98.236(p)(1)(v)]No
Compressor measured in standby-pressurized-mode? [98.236(p)(1)(vi)]Yes
Compressor measured in not-operating-depressurized-mode? [98.236(p)(1)(vii)]No
Compressor had blind flanges installed? [98.236(p)(1)(xii)]No
Power output of compressor driver (hp) [98.236(p)(1)(xiii)]1000
Compressor had scheduled depressurized shutdown during reporting year? [98.236(p)(1)(xiv)]No
Unique name or ID for reciprocating compressor [98.236(p)(1)(i)]K-9 Compressor
Total time in operating-mode (hours) [98.236(p)(1)(ii)]8570
Total time in standby-pressurized-mode (hours) [98.236(p)(1)(iii)]0
Total time in not-operating-depressurized-mode (hours) [98.236(p)(1)(iv)]190
Compressor measured in operating-mode? [98.236(p)(1)(v)]Yes
Compressor measured in standby-pressurized-mode? [98.236(p)(1)(vi)]No
Compressor measured in not-operating-depressurized-mode? [98.236(p)(1)(vii)]Yes
Compressor had blind flanges installed? [98.236(p)(1)(xii)]No
Power output of compressor driver (hp) [98.236(p)(1)(xiii)]2250
Compressor had scheduled depressurized shutdown during reporting year? [98.236(p)(1)(xiv)]Yes


ReciprocatingCompressorSourceRowDetails:
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]K-1A Inlet/Demeth Compressor/637813
Reciprocating compressor source [98.236(p)(2)(i)(B)]Blowdown valve
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]K-1A Inlet/Demeth Compressor/637813_BD
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]K-1A Inlet/Demeth Compressor/637813
Reciprocating compressor source [98.236(p)(2)(i)(B)]Isolation valve
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]K-1A Inlet/Demeth Compressor/637813_IV
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]K-1A Inlet/Demeth Compressor/637813
Reciprocating compressor source [98.236(p)(2)(i)(B)]Rod packing
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]K-1A Inlet/Demeth Compressor/637813_RP
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]K-1B Inlet/Demeth Compressor/624990
Reciprocating compressor source [98.236(p)(2)(i)(B)]Blowdown valve
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]K-1B Inlet/Demeth Compressor/624990_BD
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]K-1B Inlet/Demeth Compressor/624990
Reciprocating compressor source [98.236(p)(2)(i)(B)]Isolation valve
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]K-1B Inlet/Demeth Compressor/624990_IV
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]K-1B Inlet/Demeth Compressor/624990
Reciprocating compressor source [98.236(p)(2)(i)(B)]Rod packing
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]K-1B Inlet/Demeth Compressor/624990_RP
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]K-1C Inlet/Demeth Compressor/634331
Reciprocating compressor source [98.236(p)(2)(i)(B)]Blowdown valve
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]K-1C Inlet/Demeth Compressor/634331_BD
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]K-1C Inlet/Demeth Compressor/634331
Reciprocating compressor source [98.236(p)(2)(i)(B)]Isolation valve
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]K-1C Inlet/Demeth Compressor/634331_IV
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]K-1C Inlet/Demeth Compressor/634331
Reciprocating compressor source [98.236(p)(2)(i)(B)]Rod packing
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]K-1C Inlet/Demeth Compressor/634331_RP
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]K-1D Inlet/Demeth Compressor/625027
Reciprocating compressor source [98.236(p)(2)(i)(B)]Blowdown valve
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]K-1D Inlet/Demeth Compressor/625027_BD
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]K-1D Inlet/Demeth Compressor/625027
Reciprocating compressor source [98.236(p)(2)(i)(B)]Isolation valve
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]K-1D Inlet/Demeth Compressor/625027_IV
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]K-1D Inlet/Demeth Compressor/625027
Reciprocating compressor source [98.236(p)(2)(i)(B)]Rod packing
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]K-1D Inlet/Demeth Compressor/625027_RP
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]K-4A Dehy. Regen Compressor/625031
Reciprocating compressor source [98.236(p)(2)(i)(B)]Blowdown valve
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]K-4A Dehy. Regen Compressor/625031_BD
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]K-4A Dehy. Regen Compressor/625031
Reciprocating compressor source [98.236(p)(2)(i)(B)]Isolation valve
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]K-4A Dehy. Regen Compressor/625031_IV
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]K-4A Dehy. Regen Compressor/625031
Reciprocating compressor source [98.236(p)(2)(i)(B)]Rod packing
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]K-4A Dehy. Regen Compressor/625031_RP
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]K-4B Dehy. Regen Compressor/638446
Reciprocating compressor source [98.236(p)(2)(i)(B)]Blowdown valve
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]K-4B Dehy. Regen Compressor/638446_BD
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]K-4B Dehy. Regen Compressor/638446
Reciprocating compressor source [98.236(p)(2)(i)(B)]Isolation valve
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]K-4B Dehy. Regen Compressor/638446_IV
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]K-4B Dehy. Regen Compressor/638446
Reciprocating compressor source [98.236(p)(2)(i)(B)]Rod packing
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]K-4B Dehy. Regen Compressor/638446_RP
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]K-5A Recycle CO2 Compressor/625032
Reciprocating compressor source [98.236(p)(2)(i)(B)]Blowdown valve
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]K-5A Recycle CO2 Compressor/625032_BD
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]K-5A Recycle CO2 Compressor/625032
Reciprocating compressor source [98.236(p)(2)(i)(B)]Isolation valve
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]K-5A Recycle CO2 Compressor/625032_IV
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]K-5A Recycle CO2 Compressor/625032
Reciprocating compressor source [98.236(p)(2)(i)(B)]Rod packing
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]K-5A Recycle CO2 Compressor/625032_RP
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]K-5B Recycle CO2 Compressor/633637
Reciprocating compressor source [98.236(p)(2)(i)(B)]Blowdown valve
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]K-5B Recycle CO2 Compressor/633637_BD
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]K-5B Recycle CO2 Compressor/633637
Reciprocating compressor source [98.236(p)(2)(i)(B)]Isolation valve
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]K-5B Recycle CO2 Compressor/633637_IV
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]K-5B Recycle CO2 Compressor/633637
Reciprocating compressor source [98.236(p)(2)(i)(B)]Rod packing
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]K-5B Recycle CO2 Compressor/633637_RP
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]K-5C Recycle CO2 Compressor/637334
Reciprocating compressor source [98.236(p)(2)(i)(B)]Blowdown valve
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]K-5C Recycle CO2 Compressor/637334_BD
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]K-5C Recycle CO2 Compressor/637334
Reciprocating compressor source [98.236(p)(2)(i)(B)]Isolation valve
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]K-5C Recycle CO2 Compressor/637334_IV
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]K-5C Recycle CO2 Compressor/637334
Reciprocating compressor source [98.236(p)(2)(i)(B)]Rod packing
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]K-5C Recycle CO2 Compressor/637334_RP
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]K-9 Compressor
Reciprocating compressor source [98.236(p)(2)(i)(B)]Blowdown valve
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]K-9 Compressor_BD
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]K-9 Compressor
Reciprocating compressor source [98.236(p)(2)(i)(B)]Isolation valve
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]K-9 Compressor_IV
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]K-9 Compressor
Reciprocating compressor source [98.236(p)(2)(i)(B)]Rod packing
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]K-9 Compressor_RP


ReciprocatingCompressorsLeakOrVentSampleDataRowDetails:
Unique Name or ID for leak or vent (Specify) [98.236(p)(2)(i)(C)] [98.236(p)(3)(i)(A)]K-1A Inlet/Demeth Compressor/637813_RP
Measurement date (mm/dd/yyyy) [98.236(p)(3)(i)(B)]2022-12-07
Measurement method [98.236(p)(3)(i)(C)]Screening/Optical gas imaging
Measured flow rate (standard cubic feet/hour) [98.236(p)(3)(i)(D)]0
Is the measurement location prior to or after commingling with non-compressor emission sources? [98.236(p)(3)(i)(F)]Not manifolded
Compressors in “Operating mode”K-1A Inlet/Demeth Compressor/637813_RP
Unique Name or ID for leak or vent (Specify) [98.236(p)(2)(i)(C)] [98.236(p)(3)(i)(A)]K-1B Inlet/Demeth Compressor/624990_RP
Measurement date (mm/dd/yyyy) [98.236(p)(3)(i)(B)]2022-12-07
Measurement method [98.236(p)(3)(i)(C)]Screening/Optical gas imaging
Measured flow rate (standard cubic feet/hour) [98.236(p)(3)(i)(D)]0
Is the measurement location prior to or after commingling with non-compressor emission sources? [98.236(p)(3)(i)(F)]Not manifolded
Compressors in “Operating mode”K-1B Inlet/Demeth Compressor/624990_RP
Unique Name or ID for leak or vent (Specify) [98.236(p)(2)(i)(C)] [98.236(p)(3)(i)(A)]K-1C Inlet/Demeth Compressor/634331_RP
Measurement date (mm/dd/yyyy) [98.236(p)(3)(i)(B)]2022-12-07
Measurement method [98.236(p)(3)(i)(C)]Screening/Optical gas imaging
Measured flow rate (standard cubic feet/hour) [98.236(p)(3)(i)(D)]0
Is the measurement location prior to or after commingling with non-compressor emission sources? [98.236(p)(3)(i)(F)]Not manifolded
Compressors in “Operating mode”K-1C Inlet/Demeth Compressor/634331_RP
Unique Name or ID for leak or vent (Specify) [98.236(p)(2)(i)(C)] [98.236(p)(3)(i)(A)]K-4A Dehy. Regen Compressor/625031_BD
Measurement date (mm/dd/yyyy) [98.236(p)(3)(i)(B)]2022-12-07
Measurement method [98.236(p)(3)(i)(C)]Screening/Optical gas imaging
Measured flow rate (standard cubic feet/hour) [98.236(p)(3)(i)(D)]0
Is the measurement location prior to or after commingling with non-compressor emission sources? [98.236(p)(3)(i)(F)]Not manifolded
Compressors in “Operating mode”K-4A Dehy. Regen Compressor/625031_BD
Unique Name or ID for leak or vent (Specify) [98.236(p)(2)(i)(C)] [98.236(p)(3)(i)(A)]K-4A Dehy. Regen Compressor/625031_RP
Measurement date (mm/dd/yyyy) [98.236(p)(3)(i)(B)]2022-12-07
Measurement method [98.236(p)(3)(i)(C)]Screening/Optical gas imaging
Measured flow rate (standard cubic feet/hour) [98.236(p)(3)(i)(D)]0
Is the measurement location prior to or after commingling with non-compressor emission sources? [98.236(p)(3)(i)(F)]Not manifolded
Compressors in “Operating mode”K-4A Dehy. Regen Compressor/625031_RP
Unique Name or ID for leak or vent (Specify) [98.236(p)(2)(i)(C)] [98.236(p)(3)(i)(A)]K-4B Dehy. Regen Compressor/638446_BD
Measurement date (mm/dd/yyyy) [98.236(p)(3)(i)(B)]2022-12-07
Measurement method [98.236(p)(3)(i)(C)]High volume sampler
Measured flow rate (standard cubic feet/hour) [98.236(p)(3)(i)(D)]16.318
Is the measurement location prior to or after commingling with non-compressor emission sources? [98.236(p)(3)(i)(F)]Not manifolded
Compressors in “Operating mode”K-4B Dehy. Regen Compressor/638446_BD
Unique Name or ID for leak or vent (Specify) [98.236(p)(2)(i)(C)] [98.236(p)(3)(i)(A)]K-4B Dehy. Regen Compressor/638446_RP
Measurement date (mm/dd/yyyy) [98.236(p)(3)(i)(B)]2022-12-07
Measurement method [98.236(p)(3)(i)(C)]High volume sampler
Measured flow rate (standard cubic feet/hour) [98.236(p)(3)(i)(D)]29.789
Is the measurement location prior to or after commingling with non-compressor emission sources? [98.236(p)(3)(i)(F)]Not manifolded
Compressors in “Operating mode”K-4B Dehy. Regen Compressor/638446_RP
Unique Name or ID for leak or vent (Specify) [98.236(p)(2)(i)(C)] [98.236(p)(3)(i)(A)]K-5A Recycle CO2 Compressor/625032_RP
Measurement date (mm/dd/yyyy) [98.236(p)(3)(i)(B)]2022-12-07
Measurement method [98.236(p)(3)(i)(C)]Screening/Optical gas imaging
Measured flow rate (standard cubic feet/hour) [98.236(p)(3)(i)(D)]0
Is the measurement location prior to or after commingling with non-compressor emission sources? [98.236(p)(3)(i)(F)]Not manifolded
Compressors in “Operating mode”K-5A Recycle CO2 Compressor/625032_RP
Unique Name or ID for leak or vent (Specify) [98.236(p)(2)(i)(C)] [98.236(p)(3)(i)(A)]K-5B Recycle CO2 Compressor/633637_RP
Measurement date (mm/dd/yyyy) [98.236(p)(3)(i)(B)]2022-12-07
Measurement method [98.236(p)(3)(i)(C)]Screening/Optical gas imaging
Measured flow rate (standard cubic feet/hour) [98.236(p)(3)(i)(D)]0
Is the measurement location prior to or after commingling with non-compressor emission sources? [98.236(p)(3)(i)(F)]Not manifolded
Compressors in “Operating mode”K-5B Recycle CO2 Compressor/633637_RP
Unique Name or ID for leak or vent (Specify) [98.236(p)(2)(i)(C)] [98.236(p)(3)(i)(A)]K-9 Compressor_BD
Measurement date (mm/dd/yyyy) [98.236(p)(3)(i)(B)]2022-12-07
Measurement method [98.236(p)(3)(i)(C)]Acoustic leak detection
Measured flow rate (standard cubic feet/hour) [98.236(p)(3)(i)(D)]0
Is the measurement location prior to or after commingling with non-compressor emission sources? [98.236(p)(3)(i)(F)]Not manifolded
Compressors in “Operating mode”K-9 Compressor_BD
Unique Name or ID for leak or vent (Specify) [98.236(p)(2)(i)(C)] [98.236(p)(3)(i)(A)]K-9 Compressor_RP
Measurement date (mm/dd/yyyy) [98.236(p)(3)(i)(B)]2022-12-07
Measurement method [98.236(p)(3)(i)(C)]High volume sampler
Measured flow rate (standard cubic feet/hour) [98.236(p)(3)(i)(D)]21.945
Is the measurement location prior to or after commingling with non-compressor emission sources? [98.236(p)(3)(i)(F)]Not manifolded
Compressors in “Operating mode”K-9 Compressor_RP
Unique Name or ID for leak or vent (Specify) [98.236(p)(2)(i)(C)] [98.236(p)(3)(i)(A)]K-9 Compressor_IV
Measurement date (mm/dd/yyyy) [98.236(p)(3)(i)(B)]2022-04-08
Measurement method [98.236(p)(3)(i)(C)]Acoustic leak detection
Measured flow rate (standard cubic feet/hour) [98.236(p)(3)(i)(D)]0
Is the measurement location prior to or after commingling with non-compressor emission sources? [98.236(p)(3)(i)(F)]Not manifolded
Compressors in “Not-operating mode”K-9 Compressor_IV


ReciprocatingCompressorsEmissionFactorsSampleDataRowDetails:
Compressor Mode [98.236(p)(3)(ii)(A)]Operating
Compressor Source [98.236(p)(3)(ii)(A)]Blowdown valve
Compressor mode-source combination reporter emission factor, EFs,m (standard cubic feet per hour) [98.236(p)(3)(ii)(B)]2.07368
Total number of compressors measured in the compressor mode-source combination in current reporting year and preceding two reporting years, Countm [98.236(p)(3)(ii)(C)]25
Is the reporter emission factor facility-specific or based on all of the reporter's applicable facilities? [98.236(p)(3)(ii)(D)]Facility-specific
Compressor Mode [98.236(p)(3)(ii)(A)]Operating
Compressor Source [98.236(p)(3)(ii)(A)]Rod packing
Compressor mode-source combination reporter emission factor, EFs,m (standard cubic feet per hour) [98.236(p)(3)(ii)(B)]51.04312
Total number of compressors measured in the compressor mode-source combination in current reporting year and preceding two reporting years, Countm [98.236(p)(3)(ii)(C)]25
Is the reporter emission factor facility-specific or based on all of the reporter's applicable facilities? [98.236(p)(3)(ii)(D)]Facility-specific
Compressor Mode [98.236(p)(3)(ii)(A)]Standby-pressurized
Compressor Source [98.236(p)(3)(ii)(A)]Blowdown valve
Compressor mode-source combination reporter emission factor, EFs,m (standard cubic feet per hour) [98.236(p)(3)(ii)(B)]0
Total number of compressors measured in the compressor mode-source combination in current reporting year and preceding two reporting years, Countm [98.236(p)(3)(ii)(C)]3
Is the reporter emission factor facility-specific or based on all of the reporter's applicable facilities? [98.236(p)(3)(ii)(D)]Facility-specific
Compressor Mode [98.236(p)(3)(ii)(A)]Not-operating-depressurized
Compressor Source [98.236(p)(3)(ii)(A)]Isolation valve
Compressor mode-source combination reporter emission factor, EFs,m (standard cubic feet per hour) [98.236(p)(3)(ii)(B)]23.26025
Total number of compressors measured in the compressor mode-source combination in current reporting year and preceding two reporting years, Countm [98.236(p)(3)(ii)(C)]8
Is the reporter emission factor facility-specific or based on all of the reporter's applicable facilities? [98.236(p)(3)(ii)(D)]Facility-specific


ReciprocatingCompressorsLeakOrVentDataRowDetails:
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]K-1A Inlet/Demeth Compressor/637813_BD
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Flare
Percentage of time the device was operational when compressor source emissions were routed to device [98.236(p)(2)(ii)(E)]0.5
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]K-1A Inlet/Demeth Compressor/637813_IV
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]No
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)]0.0107433
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)]0.0002834
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]K-1A Inlet/Demeth Compressor/637813_RP
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]Yes
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)]0
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)]0
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]K-1B Inlet/Demeth Compressor/624990_BD
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Flare
Percentage of time the device was operational when compressor source emissions were routed to device [98.236(p)(2)(ii)(E)]0.5
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]K-1B Inlet/Demeth Compressor/624990_IV
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]No
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)]0.2127178
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)]0.0056108
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]K-1B Inlet/Demeth Compressor/624990_RP
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]Yes
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)]0
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)]0
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]K-1C Inlet/Demeth Compressor/634331_BD
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Flare
Percentage of time the device was operational when compressor source emissions were routed to device [98.236(p)(2)(ii)(E)]0.5
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]K-1C Inlet/Demeth Compressor/634331_IV
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]No
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)]0.5962545
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)]0.0157272
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]K-1C Inlet/Demeth Compressor/634331_RP
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]Yes
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)]0
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)]0
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]K-1D Inlet/Demeth Compressor/625027_BD
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Flare
Percentage of time the device was operational when compressor source emissions were routed to device [98.236(p)(2)(ii)(E)]0.5
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]K-1D Inlet/Demeth Compressor/625027_IV
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]No
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)]0.0784263
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)]0.0020686
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]K-1D Inlet/Demeth Compressor/625027_RP
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]No
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)]16.77635
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)]0.4425053
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]K-4A Dehy. Regen Compressor/625031_BD
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]Yes
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)]0
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)]0
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]K-4A Dehy. Regen Compressor/625031_IV
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]No
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)]0
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)]0
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]K-4A Dehy. Regen Compressor/625031_RP
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]Yes
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)]0
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)]0
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]K-4B Dehy. Regen Compressor/638446_BD
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]Yes
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)]6.6023016
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)]0.1741471
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]K-4B Dehy. Regen Compressor/638446_IV
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]No
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)]0
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)]0
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]K-4B Dehy. Regen Compressor/638446_RP
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]Yes
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)]12.0527003
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)]0.3179108
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]K-5A Recycle CO2 Compressor/625032_BD
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Flare
Percentage of time the device was operational when compressor source emissions were routed to device [98.236(p)(2)(ii)(E)]1
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]K-5A Recycle CO2 Compressor/625032_IV
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]No
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)]0.2245355
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)]0.0059225
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]K-5A Recycle CO2 Compressor/625032_RP
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]Yes
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)]0
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)]0
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]K-5B Recycle CO2 Compressor/633637_BD
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Flare
Percentage of time the device was operational when compressor source emissions were routed to device [98.236(p)(2)(ii)(E)]1
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]K-5B Recycle CO2 Compressor/633637_IV
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]No
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)]0.7369921
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)]0.0194394
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]K-5B Recycle CO2 Compressor/633637_RP
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]Yes
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)]0
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)]0
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]K-5C Recycle CO2 Compressor/637334_BD
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Flare
Percentage of time the device was operational when compressor source emissions were routed to device [98.236(p)(2)(ii)(E)]1
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]K-5C Recycle CO2 Compressor/637334_IV
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]No
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)]0.1213996
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)]0.0032021
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]K-5C Recycle CO2 Compressor/637334_RP
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]No
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)]0.3559906
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)]0.0093899
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]K-9 Compressor_BD
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]Yes
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)]0
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)]0
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]K-9 Compressor_IV
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]Yes
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)]0
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)]0
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]K-9 Compressor_RP
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]Yes
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)]8.6864182
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)]0.2291193


OtherEmissionsFromEquipmentLeaksDetails:
mt CO2204.5
mt CH45.39
Did this facility use leak surveys to calculate emissions from equipment leaks in accordance with 98.232 [per 98.236(q)]?Yes
Were missing data procedures used for any parameters to calculate GHG emissions? [98.235]No
Number of complete equipment leak surveys performed during the calendar year [98.236(q)(1)(i)]1
Optical gas imaging instrument as specified in §60.18 [98.234(a)(1)]Yes
Method 21 [98.234(a)(2)]No
Infrared laser beam illuminated instrument [98.234(a)(3)]No
Acoustic leak detection device [98.234(a)(5)]No
Optical gas imaging instrument as specified in §60.5397a [98.234(a)(6)]Yes
Method 21 as specified in §60.5397a [98.234(a)(7)]No


GasProcessingEmissionsFactorsRowDetails:
Component Type [98.236(q)(2)(i)]Compressor Components, Gas Service - Valve
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)]18
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)]8760
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)]108.0773875
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)]2.8507282
Component Type [98.236(q)(2)(i)]Compressor Components, Gas Service - Connector
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)]19
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)]8760
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)]42.9728187
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)]1.1334825
Component Type [98.236(q)(2)(i)]Compressor Components, Gas Service - Open-ended Line
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)]1
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)]8760
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)]6.9874831
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)]0.184307
Component Type [98.236(q)(2)(i)]Compressor Components, Gas Service - Pressure Relief Valve
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)]0
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)]0
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)]0
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)]0
Component Type [98.236(q)(2)(i)]Compressor Components, Gas Service - Meter
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)]0
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)]0
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)]0
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)]0
Component Type [98.236(q)(2)(i)]Non-Compressor Components, Gas Service - Valve
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)]17
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)]8760
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)]44.1583036
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)]1.1647517
Component Type [98.236(q)(2)(i)]Non-Compressor Components, Gas Service - Connector
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)]1
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)]8760
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)]2.3102796
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)]0.0609376
Component Type [98.236(q)(2)(i)]Non-Compressor Components, Gas Service - Open-ended Line
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)]0
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)]0
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)]0
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)]0
Component Type [98.236(q)(2)(i)]Non-Compressor components, Gas Service - Pressure Relief Valve
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)]0
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)]0
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)]0
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)]0
Component Type [98.236(q)(2)(i)]Non-Compressor components, Gas Service - Meter
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)]0
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)]0
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)]0
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)]0