Unit Name : Unit 3
Unit Type : MWC (Municipal waste combustor)
Unit Description :
Individual Unit Details:
Use Ivt Indicator: Y
Maximum Rated Heat Input Capacity:
325
(mmBtu/hr)
Emission Details:
Annual Biogenic CO2 Emissions: (metric tons)
Sample Analysis Results for MSW
First Quarter | Second Quarter | Third Quarter | Fourth Quarter |
0.56
(decimal fraction)
|
0.6
(decimal fraction)
|
0.58
(decimal fraction)
|
0.59
(decimal fraction)
|
Tier 4 Details:
Tier Methodology Start Date :
2023-01-01
Tier Methodology End Date :
2023-12-31
Tier 4 Quarter Fuel Details
First Quarter | Second Quarter | Third Quarter | Fourth Quarter |
63898
(Metric Tons)
|
53289
(Metric Tons)
|
57592
(Metric Tons)
|
53679
(Metric Tons)
|
Total Source Operating Hours:
7880
Operating Hours Details:
Operating hours in which a substitute data value was used in the emissions calculations for CO2 concentration :
24
Operating hours in which a substitute data value was used in the emissions calculations for stack gas flow rate :
7621
Operating hours in which a substitute data value was used in the emissions calculations for stack gas moisture content :
23
Non-Biogenic CO2 emission :
94810
(Metric Tons)
Biogenic CO2 emission :
133648
(Metric Tons)
Annual CO2 emission measured by CEMS :
228459
(Metric Tons)
Emissions reported for the CEMS include emissions calculated according to 98.33(a)(4)(viii) for a slipstream that bypassed the CEMS. :
Tier Fuel Details:
Fuel :
Natural Gas (Weighted U.S. Average)
Fuel Emission Details :
Total CH4 emissions | Total N2O emissions | Total CH4 emissions CO2e | Total N2O emissions CO2e |
0.00
(Metric Tons)
|
0.000
(Metric Tons)
|
0
(Metric Tons)
|
0
(Metric Tons)
|
Fuel :
Municipal Solid Waste
Fuel Emission Details :
Total CH4 emissions | Total N2O emissions | Total CH4 emissions CO2e | Total N2O emissions CO2e |
79.37
(Metric Tons)
|
10.417
(Metric Tons)
|
1984.2
(Metric Tons)
|
3104.3
(Metric Tons)
|
Unit Name : Unit 1
Unit Type : MWC (Municipal waste combustor)
Unit Description :
Individual Unit Details:
Use Ivt Indicator: Y
Maximum Rated Heat Input Capacity:
325
(mmBtu/hr)
Emission Details:
Annual Biogenic CO2 Emissions: (metric tons)
Sample Analysis Results for MSW
First Quarter | Second Quarter | Third Quarter | Fourth Quarter |
0.56
(decimal fraction)
|
0.6
(decimal fraction)
|
0.58
(decimal fraction)
|
0.6
(decimal fraction)
|
Tier 4 Details:
Tier Methodology Start Date :
2023-01-01
Tier Methodology End Date :
2023-12-31
Tier 4 Quarter Fuel Details
First Quarter | Second Quarter | Third Quarter | Fourth Quarter |
34706
(Metric Tons)
|
8447
(Metric Tons)
|
62357
(Metric Tons)
|
61830
(Metric Tons)
|
Total Source Operating Hours:
5660
Operating Hours Details:
Operating hours in which a substitute data value was used in the emissions calculations for CO2 concentration :
8
Operating hours in which a substitute data value was used in the emissions calculations for stack gas flow rate :
5706
Operating hours in which a substitute data value was used in the emissions calculations for stack gas moisture content :
8
Non-Biogenic CO2 emission :
69446
(Metric Tons)
Biogenic CO2 emission :
97894
(Metric Tons)
Annual CO2 emission measured by CEMS :
167340
(Metric Tons)
Emissions reported for the CEMS include emissions calculated according to 98.33(a)(4)(viii) for a slipstream that bypassed the CEMS. :
Tier Fuel Details:
Fuel :
Natural Gas (Weighted U.S. Average)
Fuel Emission Details :
Total CH4 emissions | Total N2O emissions | Total CH4 emissions CO2e | Total N2O emissions CO2e |
0.00
(Metric Tons)
|
0.000
(Metric Tons)
|
0
(Metric Tons)
|
0
(Metric Tons)
|
Fuel :
Municipal Solid Waste
Fuel Emission Details :
Total CH4 emissions | Total N2O emissions | Total CH4 emissions CO2e | Total N2O emissions CO2e |
57.58
(Metric Tons)
|
7.558
(Metric Tons)
|
1439.5
(Metric Tons)
|
2252.1
(Metric Tons)
|
Unit Name : Unit 2
Unit Type : MWC (Municipal waste combustor)
Unit Description :
Individual Unit Details:
Use Ivt Indicator: Y
Maximum Rated Heat Input Capacity:
325
(mmBtu/hr)
Emission Details:
Annual Biogenic CO2 Emissions: (metric tons)
Sample Analysis Results for MSW
First Quarter | Second Quarter | Third Quarter | Fourth Quarter |
0.56
(decimal fraction)
|
0.6
(decimal fraction)
|
0.58
(decimal fraction)
|
0.6
(decimal fraction)
|
Tier 4 Details:
Tier Methodology Start Date :
2023-01-01
Tier Methodology End Date :
2023-12-31
Tier 4 Quarter Fuel Details
First Quarter | Second Quarter | Third Quarter | Fourth Quarter |
61876
(Metric Tons)
|
65088
(Metric Tons)
|
58510
(Metric Tons)
|
65183
(Metric Tons)
|
Total Source Operating Hours:
8277
Operating Hours Details:
Operating hours in which a substitute data value was used in the emissions calculations for CO2 concentration :
20
Operating hours in which a substitute data value was used in the emissions calculations for stack gas flow rate :
8063
Operating hours in which a substitute data value was used in the emissions calculations for stack gas moisture content :
19
Non-Biogenic CO2 emission :
104023
(Metric Tons)
Biogenic CO2 emission :
146635
(Metric Tons)
Annual CO2 emission measured by CEMS :
250657
(Metric Tons)
Emissions reported for the CEMS include emissions calculated according to 98.33(a)(4)(viii) for a slipstream that bypassed the CEMS. :
Tier Fuel Details:
Fuel :
Natural Gas (Weighted U.S. Average)
Fuel Emission Details :
Total CH4 emissions | Total N2O emissions | Total CH4 emissions CO2e | Total N2O emissions CO2e |
0.00
(Metric Tons)
|
0.000
(Metric Tons)
|
0
(Metric Tons)
|
0
(Metric Tons)
|
Fuel :
Municipal Solid Waste
Fuel Emission Details :
Total CH4 emissions | Total N2O emissions | Total CH4 emissions CO2e | Total N2O emissions CO2e |
84.25
(Metric Tons)
|
11.058
(Metric Tons)
|
2106.2
(Metric Tons)
|
3295.2
(Metric Tons)
|