Source Reporting Form | Onshore Production [98.236(aa)(1)] |
Required for Selected Industry Segment | No |
Source Reporting Form | Facility Overview [98.236(aa)(2-11)] |
Required for Selected Industry Segment | Yes |
Source Reporting Form | Natural Gas Pneumatic Devices [98.236(b)] |
Required for Selected Industry Segment | No |
Total Reported CO2 Emissions (mt CO2) | 0.0 |
Total Reported CH4 Emissions (mt CH4) | 0.00 |
Source Reporting Form | Natural Gas Driven Pneumatic Pumps [98.236(c)] |
Required for Selected Industry Segment | No |
Total Reported CO2 Emissions (mt CO2) | 0.0 |
Total Reported CH4 Emissions (mt CH4) | 0.00 |
Source Reporting Form | Acid Gas Removal Units [98.236(d)] |
Required for Selected Industry Segment | Yes |
Total Reported CO2 Emissions (mt CO2) | 0.0 |
Source Reporting Form | Dehydrators [98.236(e)] |
Required for Selected Industry Segment | Yes |
Total Reported CO2 Emissions (mt CO2) | 0.0 |
Total Reported CH4 Emissions (mt CH4) | 0.00 |
Total Reported N2O Emissions (mt N2O) | 0.000 |
Source Reporting Form | Well Venting for Liquids Unloading [98.236(f)] |
Required for Selected Industry Segment | No |
Total Reported CO2 Emissions (mt CO2) | 0.0 |
Total Reported CH4 Emissions (mt CH4) | 0.00 |
Source Reporting Form | Completions and Workovers with Hydraulic Fracturing [98.236(g)] |
Required for Selected Industry Segment | No |
Total Reported CO2 Emissions (mt CO2) | 0.0 |
Total Reported CH4 Emissions (mt CH4) | 0.00 |
Total Reported N2O Emissions (mt N2O) | 0.000 |
Source Reporting Form | Completions and Workovers without Hydraulic Fracturing [98.236(h)] |
Required for Selected Industry Segment | No |
Total Reported CO2 Emissions (mt CO2) | 0.0 |
Total Reported CH4 Emissions (mt CH4) | 0.00 |
Total Reported N2O Emissions (mt N2O) | 0.000 |
Source Reporting Form | Blowdown Vent Stacks [98.236(i)] |
Required for Selected Industry Segment | Yes |
Total Reported CO2 Emissions (mt CO2) | 1663.1 |
Total Reported CH4 Emissions (mt CH4) | 80.41 |
Source Reporting Form | Atmospheric Storage Tanks [98.236(j)] |
Required for Selected Industry Segment | No |
Total Reported CO2 Emissions (mt CO2) | 0.0 |
Total Reported CH4 Emissions (mt CH4) | 0.00 |
Total Reported N2O Emissions (mt N2O) | 0.000 |
Source Reporting Form | Transmission Storage Tanks [98.236(k)] |
Required for Selected Industry Segment | No |
Total Reported CO2 Emissions (mt CO2) | 0.0 |
Total Reported CH4 Emissions (mt CH4) | 0.00 |
Total Reported N2O Emissions (mt N2O) | 0.000 |
Source Reporting Form | Well Testing [98.236(l)] |
Required for Selected Industry Segment | No |
Total Reported CO2 Emissions (mt CO2) | 0.0 |
Total Reported CH4 Emissions (mt CH4) | 0.00 |
Total Reported N2O Emissions (mt N2O) | 0.000 |
Source Reporting Form | Associated Gas Venting and Flaring [98.236(m)] |
Required for Selected Industry Segment | No |
Total Reported CO2 Emissions (mt CO2) | 0.0 |
Total Reported CH4 Emissions (mt CH4) | 0.00 |
Total Reported N2O Emissions (mt N2O) | 0.000 |
Source Reporting Form | Flare Stacks [98.236(n)] |
Required for Selected Industry Segment | Yes |
Total Reported CO2 Emissions (mt CO2) | 0.0 |
Total Reported CH4 Emissions (mt CH4) | 0.00 |
Total Reported N2O Emissions (mt N2O) | 0.000 |
Source Reporting Form | Centrifugal Compressors [98.236(o)] |
Required for Selected Industry Segment | Yes |
Total Reported CO2 Emissions (mt CO2) | 0.0 |
Total Reported CH4 Emissions (mt CH4) | 0.00 |
Source Reporting Form | Reciprocating Compressors [98.236(p)] |
Required for Selected Industry Segment | Yes |
Total Reported CO2 Emissions (mt CO2) | 19.5 |
Total Reported CH4 Emissions (mt CH4) | 21.13 |
Source Reporting Form | Equipment Leaks Surveys and Population Counts [98.236(q,r)] |
Required for Selected Industry Segment | Yes |
Total Reported CO2 Emissions (mt CO2) | 21.8 |
Total Reported CH4 Emissions (mt CH4) | 23.63 |
Source Reporting Form | Offshore Petroleum and Natural Gas Production [98.236(s)] |
Required for Selected Industry Segment | No |
Total Reported CO2 Emissions (mt CO2) | 0.0 |
Total Reported CH4 Emissions (mt CH4) | 0.00 |
Total Reported N2O Emissions (mt N2O) | 0.000 |
Source Reporting Form | Enhanced Oil Recovery Injection Pumps [98.236(w)] |
Required for Selected Industry Segment | No |
Total Reported CO2 Emissions (mt CO2) | 0.0 |
Source Reporting Form | Enhanced Oil Recovery Hydrocarbon Liquids [98.236(x)] |
Required for Selected Industry Segment | No |
Total Reported CO2 Emissions (mt CO2) | 0.0 |
Source Reporting Form | Combustion Equipment at Onshore Petroleum and Natural Gas Production Facilities, Onshore Petroleum and Natural Gas Gathering and Boosting Facilities, and Natural gas Distribution Facilities [98.236(z)] |
Required for Selected Industry Segment | No |
Total Reported CO2 Emissions (mt CO2) | 0.0 |
Total Reported CH4 Emissions (mt CH4) | 0.00 |
Total Reported N2O Emissions (mt N2O) | 0.000 |
Unit ID or Name [98.236(e)(1)(i)] | TRI1 (Dehy-1) |
Glycol dehydrator feed natural gas flow rate determined by engineering estimate based on best available data (MMscfd) [98.236(e)(1)(ii)] | 21.6348219 |
Dehydrator feed natural gas water content (pounds per MMscf) [98.236(e)(1)(iii)] | 16.11 |
Dehydrator outlet natural gas water content (pounds per MMscf) [98.236(e)(1)(iv)] | 0.69 |
Glycol dehydrator absorbent circulation pump type [98.236(e)(1)(v)] | Electric |
Dehydrator absorbent circulation rate (gallons per minute) [98.236(e)(1)(vi)] | 3 |
Report type of absorbent used [98.236(e)(1)(vii)] | Diethylene glycol (DEG) |
Report whether stripper gas is used in glycol dehydrator [98.236(e)(1)(viii)] | No |
Report whether a flash tank separator is used in glycol dehydrator [98.236(e)(1)(ix)] | Yes |
Total time the glycol dehydrator is operating (hours) [98.236(e)(1)(x)] | 7992 |
Temperature of the wet natural gas (°F) [98.236(e)(1)(xi)] | 87.6936262 |
Pressure of the wet natural gas (psig) [98.236(e)(1)(xii)] | 706.8733829 |
Concentration of CO2 in wet natural gas (mole fraction) [98.236(e)(1)(xiv)] | 0.2496288 |
Concentration of CH4 in wet natural gas (mole fraction) [98.236(e)(1)(xiii)] | 0.7394501 |
Were any dehydrator emissions vented to a vapor recovery device? [98.236(e)(1)(xv)] | Yes |
Were any dehydrator emissions vented to a flare or regenerator firebox/fire tubes? [98.236(e)(1)(xvi)] | No |
Were any dehydrator emissions vented to the atmosphere without being routed to a flare or regenerator firebox/fire tubes? [98.236(e)(1)(xvii)] | No |
Unit ID or Name [98.236(e)(1)(i)] | RBLR2 (Dehy-2) |
Glycol dehydrator feed natural gas flow rate determined by engineering estimate based on best available data (MMscfd) [98.236(e)(1)(ii)] | 6.6746644 |
Dehydrator feed natural gas water content (pounds per MMscf) [98.236(e)(1)(iii)] | 44.49 |
Dehydrator outlet natural gas water content (pounds per MMscf) [98.236(e)(1)(iv)] | 1.29 |
Glycol dehydrator absorbent circulation pump type [98.236(e)(1)(v)] | Electric |
Dehydrator absorbent circulation rate (gallons per minute) [98.236(e)(1)(vi)] | 3 |
Report type of absorbent used [98.236(e)(1)(vii)] | Triethylene glycol (TEG) |
Report whether stripper gas is used in glycol dehydrator [98.236(e)(1)(viii)] | No |
Report whether a flash tank separator is used in glycol dehydrator [98.236(e)(1)(ix)] | Yes |
Total time the glycol dehydrator is operating (hours) [98.236(e)(1)(x)] | 7992 |
Temperature of the wet natural gas (°F) [98.236(e)(1)(xi)] | 255 |
Pressure of the wet natural gas (psig) [98.236(e)(1)(xii)] | 234 |
Concentration of CO2 in wet natural gas (mole fraction) [98.236(e)(1)(xiv)] | 0.91071 |
Concentration of CH4 in wet natural gas (mole fraction) [98.236(e)(1)(xiii)] | 0.07818 |
Were any dehydrator emissions vented to a vapor recovery device? [98.236(e)(1)(xv)] | Yes |
Were any dehydrator emissions vented to a flare or regenerator firebox/fire tubes? [98.236(e)(1)(xvi)] | No |
Were any dehydrator emissions vented to the atmosphere without being routed to a flare or regenerator firebox/fire tubes? [98.236(e)(1)(xvii)] | No |
Unique name or ID for reciprocating compressor [98.236(p)(1)(i)] | RCIP Comp. C-8601 |
Total time in operating-mode (hours) [98.236(p)(1)(ii)] | 4248 |
Total time in standby-pressurized-mode (hours) [98.236(p)(1)(iii)] | 0 |
Total time in not-operating-depressurized-mode (hours) [98.236(p)(1)(iv)] | 4512 |
Compressor measured in operating-mode? [98.236(p)(1)(v)] | Yes |
Compressor measured in standby-pressurized-mode? [98.236(p)(1)(vi)] | No |
Compressor measured in not-operating-depressurized-mode? [98.236(p)(1)(vii)] | No |
Compressor had blind flanges installed? [98.236(p)(1)(xii)] | No |
Power output of compressor driver (hp) [98.236(p)(1)(xiii)] | 3550 |
Compressor had scheduled depressurized shutdown during reporting year? [98.236(p)(1)(xiv)] | No |
Unique name or ID for reciprocating compressor [98.236(p)(1)(i)] | RCIP Comp. C-8401 |
Total time in operating-mode (hours) [98.236(p)(1)(ii)] | 4392.75 |
Total time in standby-pressurized-mode (hours) [98.236(p)(1)(iii)] | 4367.25 |
Total time in not-operating-depressurized-mode (hours) [98.236(p)(1)(iv)] | 0 |
Compressor measured in operating-mode? [98.236(p)(1)(v)] | No |
Compressor measured in standby-pressurized-mode? [98.236(p)(1)(vi)] | Yes |
Compressor measured in not-operating-depressurized-mode? [98.236(p)(1)(vii)] | No |
Compressor had blind flanges installed? [98.236(p)(1)(xii)] | No |
Power output of compressor driver (hp) [98.236(p)(1)(xiii)] | 3550 |
Compressor had scheduled depressurized shutdown during reporting year? [98.236(p)(1)(xiv)] | No |
Unique name or ID for reciprocating compressor [98.236(p)(1)(i)] | RCIP Comp. C-8201 |
Total time in operating-mode (hours) [98.236(p)(1)(ii)] | 1888 |
Total time in standby-pressurized-mode (hours) [98.236(p)(1)(iii)] | 0 |
Total time in not-operating-depressurized-mode (hours) [98.236(p)(1)(iv)] | 6872 |
Compressor measured in operating-mode? [98.236(p)(1)(v)] | No |
Compressor measured in standby-pressurized-mode? [98.236(p)(1)(vi)] | No |
Compressor measured in not-operating-depressurized-mode? [98.236(p)(1)(vii)] | Yes |
Compressor had blind flanges installed? [98.236(p)(1)(xii)] | No |
Power output of compressor driver (hp) [98.236(p)(1)(xiii)] | 3550 |
Compressor had scheduled depressurized shutdown during reporting year? [98.236(p)(1)(xiv)] | Yes |
Unique name or ID for reciprocating compressor [98.236(p)(1)(i)] | Inlet Comp. C-9201 |
Total time in operating-mode (hours) [98.236(p)(1)(ii)] | 4415.25 |
Total time in standby-pressurized-mode (hours) [98.236(p)(1)(iii)] | 0 |
Total time in not-operating-depressurized-mode (hours) [98.236(p)(1)(iv)] | 4344.75 |
Compressor measured in operating-mode? [98.236(p)(1)(v)] | Yes |
Compressor measured in standby-pressurized-mode? [98.236(p)(1)(vi)] | No |
Compressor measured in not-operating-depressurized-mode? [98.236(p)(1)(vii)] | No |
Compressor had blind flanges installed? [98.236(p)(1)(xii)] | No |
Power output of compressor driver (hp) [98.236(p)(1)(xiii)] | 1775 |
Compressor had scheduled depressurized shutdown during reporting year? [98.236(p)(1)(xiv)] | No |
Unique name or ID for reciprocating compressor [98.236(p)(1)(i)] | Inlet Comp. C-9301 |
Total time in operating-mode (hours) [98.236(p)(1)(ii)] | 3776.5 |
Total time in standby-pressurized-mode (hours) [98.236(p)(1)(iii)] | 4983.5 |
Total time in not-operating-depressurized-mode (hours) [98.236(p)(1)(iv)] | 0 |
Compressor measured in operating-mode? [98.236(p)(1)(v)] | No |
Compressor measured in standby-pressurized-mode? [98.236(p)(1)(vi)] | Yes |
Compressor measured in not-operating-depressurized-mode? [98.236(p)(1)(vii)] | No |
Compressor had blind flanges installed? [98.236(p)(1)(xii)] | No |
Power output of compressor driver (hp) [98.236(p)(1)(xiii)] | 3500 |
Compressor had scheduled depressurized shutdown during reporting year? [98.236(p)(1)(xiv)] | No |
Unique name or ID for reciprocating compressor [98.236(p)(1)(i)] | Inlet Comp. C-9401 |
Total time in operating-mode (hours) [98.236(p)(1)(ii)] | 3815.5 |
Total time in standby-pressurized-mode (hours) [98.236(p)(1)(iii)] | 4944.5 |
Total time in not-operating-depressurized-mode (hours) [98.236(p)(1)(iv)] | 0 |
Compressor measured in operating-mode? [98.236(p)(1)(v)] | No |
Compressor measured in standby-pressurized-mode? [98.236(p)(1)(vi)] | Yes |
Compressor measured in not-operating-depressurized-mode? [98.236(p)(1)(vii)] | No |
Compressor had blind flanges installed? [98.236(p)(1)(xii)] | No |
Power output of compressor driver (hp) [98.236(p)(1)(xiii)] | 3550 |
Compressor had scheduled depressurized shutdown during reporting year? [98.236(p)(1)(xiv)] | No |
Unique name or ID for reciprocating compressor [98.236(p)(1)(i)] | Inlet Comp. C-9501 |
Total time in operating-mode (hours) [98.236(p)(1)(ii)] | 2817.5 |
Total time in standby-pressurized-mode (hours) [98.236(p)(1)(iii)] | 0 |
Total time in not-operating-depressurized-mode (hours) [98.236(p)(1)(iv)] | 5942.5 |
Compressor measured in operating-mode? [98.236(p)(1)(v)] | Yes |
Compressor measured in standby-pressurized-mode? [98.236(p)(1)(vi)] | No |
Compressor measured in not-operating-depressurized-mode? [98.236(p)(1)(vii)] | No |
Compressor had blind flanges installed? [98.236(p)(1)(xii)] | No |
Power output of compressor driver (hp) [98.236(p)(1)(xiii)] | 3550 |
Compressor had scheduled depressurized shutdown during reporting year? [98.236(p)(1)(xiv)] | No |
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)] | RCIP Comp. C-8601 |
Reciprocating compressor source [98.236(p)(2)(i)(B)] | Blowdown valve |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | RCIP Comp. C-8601_BD |
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)] | RCIP Comp. C-8601 |
Reciprocating compressor source [98.236(p)(2)(i)(B)] | Isolation valve |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | RCIP Comp. C-8601_IV |
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)] | RCIP Comp. C-8601 |
Reciprocating compressor source [98.236(p)(2)(i)(B)] | Rod packing |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | RCIP Comp. C-8601_RP |
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)] | RCIP Comp. C-8401 |
Reciprocating compressor source [98.236(p)(2)(i)(B)] | Blowdown valve |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | RCIP Comp. C-8401_BD |
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)] | RCIP Comp. C-8401 |
Reciprocating compressor source [98.236(p)(2)(i)(B)] | Isolation valve |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | RCIP Comp. C-8401_IV |
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)] | RCIP Comp. C-8401 |
Reciprocating compressor source [98.236(p)(2)(i)(B)] | Rod packing |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | RCIP Comp. C-8401_RP |
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)] | RCIP Comp. C-8201 |
Reciprocating compressor source [98.236(p)(2)(i)(B)] | Blowdown valve |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | RCIP Comp. C-8201_BD |
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)] | RCIP Comp. C-8201 |
Reciprocating compressor source [98.236(p)(2)(i)(B)] | Isolation valve |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | RCIP Comp. C-8201_IV |
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)] | RCIP Comp. C-8201 |
Reciprocating compressor source [98.236(p)(2)(i)(B)] | Rod packing |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | RCIP Comp. C-8201_RP |
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)] | Inlet Comp. C-9201 |
Reciprocating compressor source [98.236(p)(2)(i)(B)] | Blowdown valve |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | Inlet Comp. C-9201_BD |
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)] | Inlet Comp. C-9201 |
Reciprocating compressor source [98.236(p)(2)(i)(B)] | Isolation valve |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | Inlet Comp. C-9201_IV |
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)] | Inlet Comp. C-9201 |
Reciprocating compressor source [98.236(p)(2)(i)(B)] | Rod packing |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | Inlet Comp. C-9201_RP |
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)] | Inlet Comp. C-9301 |
Reciprocating compressor source [98.236(p)(2)(i)(B)] | Blowdown valve |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | Inlet Comp. C-9301_BD |
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)] | Inlet Comp. C-9301 |
Reciprocating compressor source [98.236(p)(2)(i)(B)] | Isolation valve |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | Inlet Comp. C-9301_IV |
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)] | Inlet Comp. C-9301 |
Reciprocating compressor source [98.236(p)(2)(i)(B)] | Rod packing |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | Inlet Comp. C-9301_RP |
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)] | Inlet Comp. C-9401 |
Reciprocating compressor source [98.236(p)(2)(i)(B)] | Blowdown valve |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | Inlet Comp. C-9401_BD |
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)] | Inlet Comp. C-9401 |
Reciprocating compressor source [98.236(p)(2)(i)(B)] | Isolation valve |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | Inlet Comp. C-9401_IV |
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)] | Inlet Comp. C-9401 |
Reciprocating compressor source [98.236(p)(2)(i)(B)] | Rod packing |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | Inlet Comp. C-9401_RP |
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)] | Inlet Comp. C-9501 |
Reciprocating compressor source [98.236(p)(2)(i)(B)] | Blowdown valve |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | Inlet Comp. C-9501_BD |
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)] | Inlet Comp. C-9501 |
Reciprocating compressor source [98.236(p)(2)(i)(B)] | Isolation valve |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | Inlet Comp. C-9501_IV |
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)] | Inlet Comp. C-9501 |
Reciprocating compressor source [98.236(p)(2)(i)(B)] | Rod packing |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | Inlet Comp. C-9501_RP |
Unique Name or ID for leak or vent (Specify) [98.236(p)(2)(i)(C)] [98.236(p)(3)(i)(A)] | RCIP Comp. C-8601_BD |
Measurement date (mm/dd/yyyy) [98.236(p)(3)(i)(B)] | 2023-08-14 |
Measurement method [98.236(p)(3)(i)(C)] | Acoustic leak detection |
Measured flow rate (standard cubic feet/hour) [98.236(p)(3)(i)(D)] | 0 |
Is the measurement location prior to or after commingling with non-compressor emission sources? [98.236(p)(3)(i)(F)] | Not manifolded |
Compressors in “Operating mode” | RCIP Comp. C-8601_BD |
Unique Name or ID for leak or vent (Specify) [98.236(p)(2)(i)(C)] [98.236(p)(3)(i)(A)] | RCIP Comp. C-8601_RP |
Measurement date (mm/dd/yyyy) [98.236(p)(3)(i)(B)] | 2023-08-14 |
Measurement method [98.236(p)(3)(i)(C)] | Temporary meter |
Measured flow rate (standard cubic feet/hour) [98.236(p)(3)(i)(D)] | 37.20264 |
Is the measurement location prior to or after commingling with non-compressor emission sources? [98.236(p)(3)(i)(F)] | Not manifolded |
Compressors in “Operating mode” | RCIP Comp. C-8601_RP |
Unique Name or ID for leak or vent (Specify) [98.236(p)(2)(i)(C)] [98.236(p)(3)(i)(A)] | RCIP Comp. C-8401_BD |
Measurement date (mm/dd/yyyy) [98.236(p)(3)(i)(B)] | 2023-08-14 |
Measurement method [98.236(p)(3)(i)(C)] | Screening/Optical gas imaging |
Measured flow rate (standard cubic feet/hour) [98.236(p)(3)(i)(D)] | 0 |
Is the measurement location prior to or after commingling with non-compressor emission sources? [98.236(p)(3)(i)(F)] | Not manifolded |
Compressors in *Standby-pressurized mode* | RCIP Comp. C-8401_BD |
Unique Name or ID for leak or vent (Specify) [98.236(p)(2)(i)(C)] [98.236(p)(3)(i)(A)] | RCIP Comp. C-8201_IV |
Measurement date (mm/dd/yyyy) [98.236(p)(3)(i)(B)] | 2023-08-14 |
Measurement method [98.236(p)(3)(i)(C)] | Screening/Optical gas imaging |
Measured flow rate (standard cubic feet/hour) [98.236(p)(3)(i)(D)] | 0 |
Is the measurement location prior to or after commingling with non-compressor emission sources? [98.236(p)(3)(i)(F)] | Not manifolded |
Compressors in “Not-operating mode” | RCIP Comp. C-8201_IV |
Unique Name or ID for leak or vent (Specify) [98.236(p)(2)(i)(C)] [98.236(p)(3)(i)(A)] | Inlet Comp. C-9201_BD |
Measurement date (mm/dd/yyyy) [98.236(p)(3)(i)(B)] | 2023-08-14 |
Measurement method [98.236(p)(3)(i)(C)] | Acoustic leak detection |
Measured flow rate (standard cubic feet/hour) [98.236(p)(3)(i)(D)] | 0 |
Is the measurement location prior to or after commingling with non-compressor emission sources? [98.236(p)(3)(i)(F)] | Not manifolded |
Compressors in “Operating mode” | Inlet Comp. C-9201_BD |
Unique Name or ID for leak or vent (Specify) [98.236(p)(2)(i)(C)] [98.236(p)(3)(i)(A)] | Inlet Comp. C-9201_RP |
Measurement date (mm/dd/yyyy) [98.236(p)(3)(i)(B)] | 2023-08-14 |
Measurement method [98.236(p)(3)(i)(C)] | High volume sampler |
Measured flow rate (standard cubic feet/hour) [98.236(p)(3)(i)(D)] | 1.98 |
Is the measurement location prior to or after commingling with non-compressor emission sources? [98.236(p)(3)(i)(F)] | Not manifolded |
Compressors in “Operating mode” | Inlet Comp. C-9201_RP |
Unique Name or ID for leak or vent (Specify) [98.236(p)(2)(i)(C)] [98.236(p)(3)(i)(A)] | Inlet Comp. C-9301_BD |
Measurement date (mm/dd/yyyy) [98.236(p)(3)(i)(B)] | 2023-08-14 |
Measurement method [98.236(p)(3)(i)(C)] | Acoustic leak detection |
Measured flow rate (standard cubic feet/hour) [98.236(p)(3)(i)(D)] | 0 |
Is the measurement location prior to or after commingling with non-compressor emission sources? [98.236(p)(3)(i)(F)] | Not manifolded |
Compressors in *Standby-pressurized mode* | Inlet Comp. C-9301_BD |
Unique Name or ID for leak or vent (Specify) [98.236(p)(2)(i)(C)] [98.236(p)(3)(i)(A)] | Inlet Comp. C-9401_BD |
Measurement date (mm/dd/yyyy) [98.236(p)(3)(i)(B)] | 2023-08-14 |
Measurement method [98.236(p)(3)(i)(C)] | Acoustic leak detection |
Measured flow rate (standard cubic feet/hour) [98.236(p)(3)(i)(D)] | 0 |
Is the measurement location prior to or after commingling with non-compressor emission sources? [98.236(p)(3)(i)(F)] | Not manifolded |
Compressors in *Standby-pressurized mode* | Inlet Comp. C-9401_BD |
Unique Name or ID for leak or vent (Specify) [98.236(p)(2)(i)(C)] [98.236(p)(3)(i)(A)] | Inlet Comp. C-9501_BD |
Measurement date (mm/dd/yyyy) [98.236(p)(3)(i)(B)] | 2023-08-14 |
Measurement method [98.236(p)(3)(i)(C)] | Acoustic leak detection |
Measured flow rate (standard cubic feet/hour) [98.236(p)(3)(i)(D)] | 0 |
Is the measurement location prior to or after commingling with non-compressor emission sources? [98.236(p)(3)(i)(F)] | Not manifolded |
Compressors in “Operating mode” | Inlet Comp. C-9501_BD |
Unique Name or ID for leak or vent (Specify) [98.236(p)(2)(i)(C)] [98.236(p)(3)(i)(A)] | Inlet Comp. C-9501_RP |
Measurement date (mm/dd/yyyy) [98.236(p)(3)(i)(B)] | 2023-08-14 |
Measurement method [98.236(p)(3)(i)(C)] | High volume sampler |
Measured flow rate (standard cubic feet/hour) [98.236(p)(3)(i)(D)] | 241.8 |
Is the measurement location prior to or after commingling with non-compressor emission sources? [98.236(p)(3)(i)(F)] | Not manifolded |
Compressors in “Operating mode” | Inlet Comp. C-9501_RP |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | RCIP Comp. C-8601_BD |
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)] | Single |
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)] | Atmosphere |
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)] | Yes |
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)] | No |
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)] | 0 |
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)] | 0 |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | RCIP Comp. C-8601_IV |
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)] | Single |
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)] | Atmosphere |
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)] | No |
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)] | No |
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)] | 1.5030305 |
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)] | 1.6251648 |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | RCIP Comp. C-8601_RP |
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)] | Single |
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)] | Atmosphere |
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)] | Yes |
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)] | No |
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)] | 2.0750987 |
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)] | 2.2437184 |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | RCIP Comp. C-8401_BD |
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)] | Single |
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)] | Atmosphere |
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)] | Yes |
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)] | No |
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)] | 0 |
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)] | 0 |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | RCIP Comp. C-8401_IV |
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)] | Single |
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)] | Atmosphere |
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)] | No |
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)] | No |
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)] | 0 |
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)] | 0 |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | RCIP Comp. C-8401_RP |
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)] | Single |
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)] | Atmosphere |
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)] | No |
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)] | No |
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)] | 1.1000856 |
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)] | 1.1894771 |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | RCIP Comp. C-8201_BD |
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)] | Single |
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)] | Atmosphere |
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)] | No |
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)] | No |
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)] | 0 |
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)] | 0 |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | RCIP Comp. C-8201_IV |
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)] | Single |
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)] | Atmosphere |
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)] | Yes |
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)] | No |
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)] | 0 |
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)] | 0 |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | RCIP Comp. C-8201_RP |
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)] | Single |
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)] | Atmosphere |
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)] | No |
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)] | No |
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)] | 0.4728158 |
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)] | 0.5112362 |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | Inlet Comp. C-9201_BD |
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)] | Single |
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)] | Atmosphere |
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)] | Yes |
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)] | No |
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)] | 0 |
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)] | 0 |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | Inlet Comp. C-9201_IV |
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)] | Single |
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)] | Atmosphere |
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)] | No |
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)] | No |
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)] | 1.4473165 |
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)] | 1.5649235 |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | Inlet Comp. C-9201_RP |
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)] | Single |
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)] | Atmosphere |
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)] | Yes |
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)] | No |
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)] | 0.1147892 |
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)] | 0.1241168 |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | Inlet Comp. C-9301_BD |
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)] | Single |
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)] | Atmosphere |
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)] | Yes |
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)] | No |
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)] | 0 |
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)] | 0 |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | Inlet Comp. C-9301_IV |
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)] | Single |
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)] | Atmosphere |
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)] | No |
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)] | No |
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)] | 0 |
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)] | 0 |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | Inlet Comp. C-9301_RP |
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)] | Single |
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)] | Atmosphere |
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)] | No |
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)] | No |
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)] | 0.9457568 |
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)] | 1.0226078 |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | Inlet Comp. C-9401_BD |
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)] | Single |
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)] | Atmosphere |
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)] | Yes |
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)] | No |
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)] | 0 |
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)] | 0 |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | Inlet Comp. C-9401_IV |
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)] | Single |
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)] | Atmosphere |
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)] | No |
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)] | No |
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)] | 0 |
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)] | 0 |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | Inlet Comp. C-9401_RP |
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)] | Single |
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)] | Atmosphere |
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)] | No |
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)] | No |
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)] | 0.9555237 |
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)] | 1.0331683 |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | Inlet Comp. C-9501_BD |
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)] | Single |
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)] | Atmosphere |
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)] | Yes |
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)] | No |
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)] | 0 |
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)] | 0 |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | Inlet Comp. C-9501_IV |
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)] | Single |
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)] | Atmosphere |
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)] | No |
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)] | No |
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)] | 1.9795565 |
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)] | 2.1404126 |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | Inlet Comp. C-9501_RP |
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)] | Single |
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)] | Atmosphere |
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)] | Yes |
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)] | No |
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)] | 8.9454195 |
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)] | 9.6723123 |
Component Type [98.236(q)(2)(i)] | Compressor Components, Gas Service - Valve |
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)] | 9 |
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)] | 8760 |
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)] | 15.3624686 |
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)] | 16.6108022 |
Component Type [98.236(q)(2)(i)] | Compressor Components, Gas Service - Connector |
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)] | 7 |
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)] | 8760 |
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)] | 4.500849 |
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)] | 4.866582 |
Component Type [98.236(q)(2)(i)] | Compressor Components, Gas Service - Open-ended Line |
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)] | 1 |
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)] | 8760 |
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)] | 1.9864468 |
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)] | 2.1478628 |
Component Type [98.236(q)(2)(i)] | Compressor Components, Gas Service - Pressure Relief Valve |
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)] | 0 |
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)] | 0 |
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)] | 0 |
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)] | 0 |
Component Type [98.236(q)(2)(i)] | Compressor Components, Gas Service - Meter |
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)] | 0 |
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)] | 0 |
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)] | 0 |
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)] | 0 |
Component Type [98.236(q)(2)(i)] | Non-Compressor Components, Gas Service - Valve |
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)] | 0 |
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)] | 0 |
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)] | 0 |
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)] | 0 |
Component Type [98.236(q)(2)(i)] | Non-Compressor Components, Gas Service - Connector |
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)] | 0 |
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)] | 0 |
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)] | 0 |
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)] | 0 |
Component Type [98.236(q)(2)(i)] | Non-Compressor Components, Gas Service - Open-ended Line |
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)] | 0 |
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)] | 0 |
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)] | 0 |
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)] | 0 |
Component Type [98.236(q)(2)(i)] | Non-Compressor components, Gas Service - Pressure Relief Valve |
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)] | 0 |
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)] | 0 |
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)] | 0 |
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)] | 0 |
Component Type [98.236(q)(2)(i)] | Non-Compressor components, Gas Service - Meter |
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)] | 0 |
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)] | 0 |
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)] | 0 |
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)] | 0 |
Number of days substitute data procedures were used for mass or volume:
0
Number of days substitute data procedures were used for concentration:
0