Source Reporting Form | Onshore Production [98.236(aa)(1)] |
Required for Selected Industry Segment | No |
Source Reporting Form | Facility Overview [98.236(aa)(2-11)] |
Required for Selected Industry Segment | Yes |
Source Reporting Form | Natural Gas Pneumatic Devices [98.236(b)] |
Required for Selected Industry Segment | Yes |
Total Reported CO2 Emissions (mt CO2) | 0.5 |
Total Reported CH4 Emissions (mt CH4) | 16.77 |
Source Reporting Form | Natural Gas Driven Pneumatic Pumps [98.236(c)] |
Required for Selected Industry Segment | No |
Total Reported CO2 Emissions (mt CO2) | 0.0 |
Total Reported CH4 Emissions (mt CH4) | 0.00 |
Source Reporting Form | Acid Gas Removal Units [98.236(d)] |
Required for Selected Industry Segment | No |
Total Reported CO2 Emissions (mt CO2) | 0.0 |
Source Reporting Form | Dehydrators [98.236(e)] |
Required for Selected Industry Segment | No |
Total Reported CO2 Emissions (mt CO2) | 0.0 |
Total Reported CH4 Emissions (mt CH4) | 0.00 |
Total Reported N2O Emissions (mt N2O) | 0.000 |
Source Reporting Form | Well Venting for Liquids Unloading [98.236(f)] |
Required for Selected Industry Segment | No |
Total Reported CO2 Emissions (mt CO2) | 0.0 |
Total Reported CH4 Emissions (mt CH4) | 0.00 |
Source Reporting Form | Completions and Workovers with Hydraulic Fracturing [98.236(g)] |
Required for Selected Industry Segment | No |
Total Reported CO2 Emissions (mt CO2) | 0.0 |
Total Reported CH4 Emissions (mt CH4) | 0.00 |
Total Reported N2O Emissions (mt N2O) | 0.000 |
Source Reporting Form | Completions and Workovers without Hydraulic Fracturing [98.236(h)] |
Required for Selected Industry Segment | No |
Total Reported CO2 Emissions (mt CO2) | 0.0 |
Total Reported CH4 Emissions (mt CH4) | 0.00 |
Total Reported N2O Emissions (mt N2O) | 0.000 |
Source Reporting Form | Blowdown Vent Stacks [98.236(i)] |
Required for Selected Industry Segment | Yes |
Total Reported CO2 Emissions (mt CO2) | 0.3 |
Total Reported CH4 Emissions (mt CH4) | 10.07 |
Source Reporting Form | Atmospheric Storage Tanks [98.236(j)] |
Required for Selected Industry Segment | No |
Total Reported CO2 Emissions (mt CO2) | 0.0 |
Total Reported CH4 Emissions (mt CH4) | 0.00 |
Total Reported N2O Emissions (mt N2O) | 0.000 |
Source Reporting Form | Transmission Storage Tanks [98.236(k)] |
Required for Selected Industry Segment | Yes |
Total Reported CO2 Emissions (mt CO2) | 0.3 |
Total Reported CH4 Emissions (mt CH4) | 11.42 |
Total Reported N2O Emissions (mt N2O) | 0.000 |
Source Reporting Form | Well Testing [98.236(l)] |
Required for Selected Industry Segment | No |
Total Reported CO2 Emissions (mt CO2) | 0.0 |
Total Reported CH4 Emissions (mt CH4) | 0.00 |
Total Reported N2O Emissions (mt N2O) | 0.000 |
Source Reporting Form | Associated Gas Venting and Flaring [98.236(m)] |
Required for Selected Industry Segment | No |
Total Reported CO2 Emissions (mt CO2) | 0.0 |
Total Reported CH4 Emissions (mt CH4) | 0.00 |
Total Reported N2O Emissions (mt N2O) | 0.000 |
Source Reporting Form | Flare Stacks [98.236(n)] |
Required for Selected Industry Segment | Yes |
Total Reported CO2 Emissions (mt CO2) | 0.0 |
Total Reported CH4 Emissions (mt CH4) | 0.00 |
Total Reported N2O Emissions (mt N2O) | 0.000 |
Source Reporting Form | Centrifugal Compressors [98.236(o)] |
Required for Selected Industry Segment | Yes |
Total Reported CO2 Emissions (mt CO2) | 0.0 |
Total Reported CH4 Emissions (mt CH4) | 0.46 |
Source Reporting Form | Reciprocating Compressors [98.236(p)] |
Required for Selected Industry Segment | Yes |
Total Reported CO2 Emissions (mt CO2) | 4.5 |
Total Reported CH4 Emissions (mt CH4) | 154.61 |
Source Reporting Form | Equipment Leaks Surveys and Population Counts [98.236(q,r)] |
Required for Selected Industry Segment | Yes |
Total Reported CO2 Emissions (mt CO2) | 0.1 |
Total Reported CH4 Emissions (mt CH4) | 2.11 |
Source Reporting Form | Offshore Petroleum and Natural Gas Production [98.236(s)] |
Required for Selected Industry Segment | No |
Total Reported CO2 Emissions (mt CO2) | 0.0 |
Total Reported CH4 Emissions (mt CH4) | 0.00 |
Total Reported N2O Emissions (mt N2O) | 0.000 |
Source Reporting Form | Enhanced Oil Recovery Injection Pumps [98.236(w)] |
Required for Selected Industry Segment | No |
Total Reported CO2 Emissions (mt CO2) | 0.0 |
Source Reporting Form | Enhanced Oil Recovery Hydrocarbon Liquids [98.236(x)] |
Required for Selected Industry Segment | No |
Total Reported CO2 Emissions (mt CO2) | 0.0 |
Source Reporting Form | Combustion Equipment at Onshore Petroleum and Natural Gas Production Facilities, Onshore Petroleum and Natural Gas Gathering and Boosting Facilities, and Natural gas Distribution Facilities [98.236(z)] |
Required for Selected Industry Segment | No |
Total Reported CO2 Emissions (mt CO2) | 0.0 |
Total Reported CH4 Emissions (mt CH4) | 0.00 |
Total Reported N2O Emissions (mt N2O) | 0.000 |
Compressor Mode [98.236(o)(3)(ii)(A)] | Operating |
Compressor Source [98.236(o)(3)(ii)(A)] | Wet seal |
Compressor mode-source combination reporter emission factor, EFs,m (standard cubic feet per hour) [98.236(o)(3)(ii)(B)] | 88.54695 |
Total number of compressors measured in the compressor mode-source combination in current reporting year and preceding two reporting years [98.236(o)(3)(ii)(C)] | 65 |
Is the reporter emission factor facility-specific or based on all of the reporter's applicable facilities? [98.236(o)(3)(ii)(D)] | All applicable facilities |
Compressor Mode [98.236(o)(3)(ii)(A)] | Operating |
Compressor Source [98.236(o)(3)(ii)(A)] | Blowdown valve |
Compressor mode-source combination reporter emission factor, EFs,m (standard cubic feet per hour) [98.236(o)(3)(ii)(B)] | 363.91976 |
Total number of compressors measured in the compressor mode-source combination in current reporting year and preceding two reporting years [98.236(o)(3)(ii)(C)] | 206 |
Is the reporter emission factor facility-specific or based on all of the reporter's applicable facilities? [98.236(o)(3)(ii)(D)] | All applicable facilities |
Compressor Mode [98.236(o)(3)(ii)(A)] | Not-operating |
Compressor Source [98.236(o)(3)(ii)(A)] | Isolation valve |
Compressor mode-source combination reporter emission factor, EFs,m (standard cubic feet per hour) [98.236(o)(3)(ii)(B)] | 255.76264 |
Total number of compressors measured in the compressor mode-source combination in current reporting year and preceding two reporting years [98.236(o)(3)(ii)(C)] | 222 |
Is the reporter emission factor facility-specific or based on all of the reporter's applicable facilities? [98.236(o)(3)(ii)(D)] | All applicable facilities |
Unique Name or ID for leak or vent [98.236(o)(2)(i)(C)] | 44020-Blowdown valve |
Leak or vent for a single compressor source or a manifolded group? [98.236(o)(2)(ii)(A)] [98.236(o)(1)(vi)] | Single |
Where are leak or vent emissions released? [98.236(o)(2)(ii)(A)] [98.236(o)(1)(vii) through (ix)] | Atmosphere |
Was an "as found" measurement conducted on the leak or vent? [98.236(o)(2)(ii)(B)] | Yes |
Were continuous measurements conducted on the leak or vent? [98.236(o)(2)(ii)(C)] | No |
CO2 emissions vented to atmosphere (mt CO2) [98.236(o)(2)(ii)(D)(1)] | 0 |
CH4 emissions vented to atmosphere (mt CH4) [98.236(o)(2)(ii)(D)(2)] | 0 |
Unique Name or ID for leak or vent [98.236(o)(2)(i)(C)] | 44020-Isolation valve |
Leak or vent for a single compressor source or a manifolded group? [98.236(o)(2)(ii)(A)] [98.236(o)(1)(vi)] | Single |
Where are leak or vent emissions released? [98.236(o)(2)(ii)(A)] [98.236(o)(1)(vii) through (ix)] | Atmosphere |
Was an "as found" measurement conducted on the leak or vent? [98.236(o)(2)(ii)(B)] | No |
Were continuous measurements conducted on the leak or vent? [98.236(o)(2)(ii)(C)] | No |
CO2 emissions vented to atmosphere (mt CO2) [98.236(o)(2)(ii)(D)(1)] | 0.00505 |
CH4 emissions vented to atmosphere (mt CH4) [98.236(o)(2)(ii)(D)(2)] | 0.17503 |
Unique Name or ID for leak or vent [98.236(o)(2)(i)(C)] | 44020-Wet seal |
Leak or vent for a single compressor source or a manifolded group? [98.236(o)(2)(ii)(A)] [98.236(o)(1)(vi)] | Single |
Where are leak or vent emissions released? [98.236(o)(2)(ii)(A)] [98.236(o)(1)(vii) through (ix)] | Atmosphere |
Was an "as found" measurement conducted on the leak or vent? [98.236(o)(2)(ii)(B)] | Yes |
Were continuous measurements conducted on the leak or vent? [98.236(o)(2)(ii)(C)] | No |
CO2 emissions vented to atmosphere (mt CO2) [98.236(o)(2)(ii)(D)(1)] | 0.00818 |
CH4 emissions vented to atmosphere (mt CH4) [98.236(o)(2)(ii)(D)(2)] | 0.28362 |
Unique name or ID for reciprocating compressor [98.236(p)(1)(i)] | 44018 |
Total time in operating-mode (hours) [98.236(p)(1)(ii)] | 3339.49306 |
Total time in standby-pressurized-mode (hours) [98.236(p)(1)(iii)] | 4874.46138 |
Total time in not-operating-depressurized-mode (hours) [98.236(p)(1)(iv)] | 546.04556 |
Compressor measured in operating-mode? [98.236(p)(1)(v)] | No |
Compressor measured in standby-pressurized-mode? [98.236(p)(1)(vi)] | No |
Compressor measured in not-operating-depressurized-mode? [98.236(p)(1)(vii)] | Yes |
Compressor had blind flanges installed? [98.236(p)(1)(xii)] | No |
Power output of compressor driver (hp) [98.236(p)(1)(xiii)] | 3300 |
Compressor had scheduled depressurized shutdown during reporting year? [98.236(p)(1)(xiv)] | Yes |
Unique name or ID for reciprocating compressor [98.236(p)(1)(i)] | 44019 |
Total time in operating-mode (hours) [98.236(p)(1)(ii)] | 7138.48334 |
Total time in standby-pressurized-mode (hours) [98.236(p)(1)(iii)] | 1614.28666 |
Total time in not-operating-depressurized-mode (hours) [98.236(p)(1)(iv)] | 7.23333 |
Compressor measured in operating-mode? [98.236(p)(1)(v)] | Yes |
Compressor measured in standby-pressurized-mode? [98.236(p)(1)(vi)] | No |
Compressor measured in not-operating-depressurized-mode? [98.236(p)(1)(vii)] | No |
Compressor had blind flanges installed? [98.236(p)(1)(xii)] | No |
Power output of compressor driver (hp) [98.236(p)(1)(xiii)] | 3300 |
Compressor had scheduled depressurized shutdown during reporting year? [98.236(p)(1)(xiv)] | No |
Unique Name or ID for leak or vent (Specify) [98.236(p)(2)(i)(C)] [98.236(p)(3)(i)(A)] | 44018-Isolation valve |
Measurement date (mm/dd/yyyy) [98.236(p)(3)(i)(B)] | 2023-03-01 |
Measurement method [98.236(p)(3)(i)(C)] | Temporary meter |
Measured flow rate (standard cubic feet/hour) [98.236(p)(3)(i)(D)] | 357.2502 |
Is the measurement location prior to or after commingling with non-compressor emission sources? [98.236(p)(3)(i)(F)] | Not manifolded |
Compressors in “Not-operating mode” | 44018 |
Unique Name or ID for leak or vent (Specify) [98.236(p)(2)(i)(C)] [98.236(p)(3)(i)(A)] | 44019-Rod packing |
Measurement date (mm/dd/yyyy) [98.236(p)(3)(i)(B)] | 2023-03-01 |
Measurement method [98.236(p)(3)(i)(C)] | Temporary meter |
Measured flow rate (standard cubic feet/hour) [98.236(p)(3)(i)(D)] | 774.042 |
Is the measurement location prior to or after commingling with non-compressor emission sources? [98.236(p)(3)(i)(F)] | Not manifolded |
Compressors in “Operating mode” | 44019 |
Unique Name or ID for leak or vent (Specify) [98.236(p)(2)(i)(C)] [98.236(p)(3)(i)(A)] | 44019-Blowdown valve |
Measurement date (mm/dd/yyyy) [98.236(p)(3)(i)(B)] | 2023-03-01 |
Measurement method [98.236(p)(3)(i)(C)] | Screening/Acoustic leak detection |
Measured flow rate (standard cubic feet/hour) [98.236(p)(3)(i)(D)] | 0 |
Is the measurement location prior to or after commingling with non-compressor emission sources? [98.236(p)(3)(i)(F)] | Not manifolded |
Compressors in “Operating mode” | 44019 |
Compressor Mode [98.236(p)(3)(ii)(A)] | Operating |
Compressor Source [98.236(p)(3)(ii)(A)] | Blowdown valve |
Compressor mode-source combination reporter emission factor, EFs,m (standard cubic feet per hour) [98.236(p)(3)(ii)(B)] | 115.92866 |
Total number of compressors measured in the compressor mode-source combination in current reporting year and preceding two reporting years, Countm [98.236(p)(3)(ii)(C)] | 444 |
Is the reporter emission factor facility-specific or based on all of the reporter's applicable facilities? [98.236(p)(3)(ii)(D)] | All applicable facilities |
Compressor Mode [98.236(p)(3)(ii)(A)] | Operating |
Compressor Source [98.236(p)(3)(ii)(A)] | Rod packing |
Compressor mode-source combination reporter emission factor, EFs,m (standard cubic feet per hour) [98.236(p)(3)(ii)(B)] | 438.60826 |
Total number of compressors measured in the compressor mode-source combination in current reporting year and preceding two reporting years, Countm [98.236(p)(3)(ii)(C)] | 443 |
Is the reporter emission factor facility-specific or based on all of the reporter's applicable facilities? [98.236(p)(3)(ii)(D)] | All applicable facilities |
Compressor Mode [98.236(p)(3)(ii)(A)] | Standby-pressurized |
Compressor Source [98.236(p)(3)(ii)(A)] | Blowdown valve |
Compressor mode-source combination reporter emission factor, EFs,m (standard cubic feet per hour) [98.236(p)(3)(ii)(B)] | 139.22608 |
Total number of compressors measured in the compressor mode-source combination in current reporting year and preceding two reporting years, Countm [98.236(p)(3)(ii)(C)] | 214 |
Is the reporter emission factor facility-specific or based on all of the reporter's applicable facilities? [98.236(p)(3)(ii)(D)] | All applicable facilities |
Compressor Mode [98.236(p)(3)(ii)(A)] | Not-operating-depressurized |
Compressor Source [98.236(p)(3)(ii)(A)] | Isolation valve |
Compressor mode-source combination reporter emission factor, EFs,m (standard cubic feet per hour) [98.236(p)(3)(ii)(B)] | 89.66093 |
Total number of compressors measured in the compressor mode-source combination in current reporting year and preceding two reporting years, Countm [98.236(p)(3)(ii)(C)] | 599 |
Is the reporter emission factor facility-specific or based on all of the reporter's applicable facilities? [98.236(p)(3)(ii)(D)] | All applicable facilities |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | 44018-Blowdown valve |
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)] | Single |
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)] | Atmosphere |
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)] | No |
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)] | No |
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)] | 0.5606082 |
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)] | 19.4401027 |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | 44018-Isolation valve |
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)] | Single |
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)] | Atmosphere |
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)] | Yes |
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)] | No |
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)] | 0.1026094 |
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)] | 3.5581659 |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | 44018-Rod packing |
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)] | Single |
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)] | Atmosphere |
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)] | No |
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)] | No |
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)] | 0.7704476 |
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)] | 26.7166613 |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | 44019-Blowdown valve |
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)] | Single |
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)] | Atmosphere |
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)] | Yes |
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)] | No |
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)] | 0.11822 |
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)] | 4.09945 |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | 44019-Isolation valve |
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)] | Single |
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)] | Atmosphere |
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)] | No |
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)] | No |
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)] | 0.00034 |
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)] | 0.01183 |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | 44019-Rod packing |
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)] | Single |
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)] | Atmosphere |
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)] | Yes |
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)] | No |
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)] | 2.90641 |
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)] | 100.78486 |
Component Type [98.236(q)(2)(i)] | Compressor Components, Gas Service - Valve |
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)] | 0 |
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)] | 0 |
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)] | 0 |
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)] | 0 |
Component Type [98.236(q)(2)(i)] | Compressor Components, Gas Service - Connector |
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)] | 0 |
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)] | 0 |
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)] | 0 |
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)] | 0 |
Component Type [98.236(q)(2)(i)] | Compressor Components, Gas Service - Open-ended Line |
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)] | 0 |
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)] | 0 |
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)] | 0 |
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)] | 0 |
Component Type [98.236(q)(2)(i)] | Compressor Components, Gas Service - Pressure Relief Valve |
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)] | 0 |
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)] | 0 |
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)] | 0 |
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)] | 0 |
Component Type [98.236(q)(2)(i)] | Compressor Components, Gas Service - Meter or Instrument |
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)] | 0 |
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)] | 0 |
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)] | 0 |
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)] | 0 |
Component Type [98.236(q)(2)(i)] | Compressor Components, Gas Service - Other |
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)] | 0 |
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)] | 0 |
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)] | 0 |
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)] | 0 |
Component Type [98.236(q)(2)(i)] | Non-Compressor Components, Gas Service - Valve |
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)] | 2 |
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)] | 8760 |
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)] | 0.06508 |
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)] | 2.1056 |
Component Type [98.236(q)(2)(i)] | Non-Compressor Components, Gas Service - Connector |
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)] | 0 |
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)] | 0 |
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)] | 0 |
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)] | 0 |
Component Type [98.236(q)(2)(i)] | Non-Compressor Components, Gas Service - Open-ended Line |
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)] | 0 |
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)] | 0 |
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)] | 0 |
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)] | 0 |
Component Type [98.236(q)(2)(i)] | Non-Compressor components, Gas Service - Pressure Relief Valve |
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)] | 0 |
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)] | 0 |
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)] | 0 |
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)] | 0 |
Component Type [98.236(q)(2)(i)] | Non-Compressor components, Gas Service - Meter or Instrument |
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)] | 0 |
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)] | 0 |
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)] | 0 |
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)] | 0 |
Component Type [98.236(q)(2)(i)] | Non-Compressor components, Gas Service - Other |
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)] | 0 |
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)] | 0 |
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)] | 0 |
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)] | 0 |