Facility Name:ContangoResources_LOST CABIN
Facility Identifier:
Facility Reporting Year:2023
Facility Location:
Address: 165 LOST CABIN Road
City: Lysite
State: WY
Postal Code: 82642

Facility Site Details:
CO2 equivalent emissions from facility subparts C-II, SS, and TT (metric tons):183,282.8
CO2 equivalent emissions from supplier subparts LL-QQ (metric tons):
Biogenic CO2 emissions from facility subparts C-II, SS, and TT (metric tons):0
Cogeneration Unit Emissions Indicator:N
GHG Report Start Date:2023-01-01
GHG Report End Date:2023-12-31
Description of Changes to Calculation Methodology:
Plant Code Indicator:N
Primary NAICS Code:211130
Second Primary NAICS Code:

Parent Company Details:
Parent Company Name:CONTANGO RESOURCES LLC
Address:1717 S Boulder Ave, Suite 900, Tulsa,  OK 74119
Percent Ownership Interest:100

Subpart C: General Stationary Fuel Combustion

Gas Information Details

Gas NameCarbon Dioxide
Gas Quantity59,537.9 (Metric Tons)
Own Result?

Gas NameBiogenic Carbon dioxide
Gas Quantity0 (Metric Tons)
Own Result?

Gas NameMethane
Gas Quantity1.12 (Metric Tons)
Own Result?

Gas NameNitrous Oxide
Gas Quantity0.112 (Metric Tons)
Own Result?

Unit Details:
Unit Name : CP-4501-3
Unit Description :
Common Pipe Details:
Use Ivt Indicator: N
Maximum Rated Heat Input Capacity: 173.6
Cumulative Maximum Rated Heat Input Capacity: 173.6

Emission Details:
Annual Biogenic CO2 Emissions: 0 (metric tons)
Annual Fossil fuel based CO2 Emissions: 40262.1 (metric tons)

Tier Fuel Details:
Fuel : Natural Gas (Weighted U.S. Average)
Tier Name : Tier 2 (Equation C-2a)
Tier Methodology Start Date : 2023-01-01
Tier Methodology End Date : 2023-12-31
Frequency of HHV determinations : Monthly

Tier 2 Monthly HHV Details :
JanuaryFebruaryMarchAprilMayJuneJulyAugustSeptemberOctoberNovemberDecember
N N N N N N N N N N N N

Fuel Emission Details :
Total CO2 emissionsTotal CH4 emissionsTotal N2O emissionsTotal CH4 emissions CO2eTotal N2O emissions CO2e
40262.1 (Metric Tons) 0.76 (Metric Tons) 0.076 (Metric Tons) 19 (Metric Tons) 22.6 (Metric Tons)

Equation C2a/C9a Inputs :
Fuel Quantity : 770776389.12 (scf/year)
Use Default High Heat Value : false
Equation C2b Inputs :
Fuel CombustedHigh Heat Value
January83643139 (scf/month)0.0009833700 (mmBtu/scf)
February73812370 (scf/month)0.0009836000 (mmBtu/scf)
March80450573 (scf/month)0.0009833800 (mmBtu/scf)
April60165747 (scf/month)0.0009837800 (mmBtu/scf)
May75694653 (scf/month)0.0009847800 (mmBtu/scf)
June61481484 (scf/month)0.0009846300 (mmBtu/scf)
July70787304 (scf/month)0.0009851600 (mmBtu/scf)
August38015334 (scf/month)0.0009849500 (mmBtu/scf)
September34948007 (scf/month)0.0009847800 (mmBtu/scf)
October50860685 (scf/month)0.0009857500 (mmBtu/scf)
November70540474 (scf/month)0.0009848500 (mmBtu/scf)
December70376619 (scf/month)0.0009856000 (mmBtu/scf)

Unit Name : CP-4501
Unit Description :
Common Pipe Details:
Use Ivt Indicator: N
Maximum Rated Heat Input Capacity: 58.4
Cumulative Maximum Rated Heat Input Capacity: 58.4

Emission Details:
Annual Biogenic CO2 Emissions: 0 (metric tons)
Annual Fossil fuel based CO2 Emissions: 19275.8 (metric tons)

Tier Fuel Details:
Fuel : Natural Gas (Weighted U.S. Average)
Tier Name : Tier 2 (Equation C-2a)
Tier Methodology Start Date : 2023-01-01
Tier Methodology End Date : 2023-12-31
Frequency of HHV determinations : Monthly

Tier 2 Monthly HHV Details :
JanuaryFebruaryMarchAprilMayJuneJulyAugustSeptemberOctoberNovemberDecember
N N N N N N N N N N N N

Fuel Emission Details :
Total CO2 emissionsTotal CH4 emissionsTotal N2O emissionsTotal CH4 emissions CO2eTotal N2O emissions CO2e
19275.8 (Metric Tons) 0.36 (Metric Tons) 0.036 (Metric Tons) 9.1 (Metric Tons) 10.8 (Metric Tons)

Equation C2a/C9a Inputs :
Fuel Quantity : 369002857.93 (scf/year)
Use Default High Heat Value : false
Equation C2b Inputs :
Fuel CombustedHigh Heat Value
January38917280 (scf/month)0.0009833700 (mmBtu/scf)
February35487878 (scf/month)0.0009836000 (mmBtu/scf)
March34647017 (scf/month)0.0009833800 (mmBtu/scf)
April30782325 (scf/month)0.0009837800 (mmBtu/scf)
May16121016 (scf/month)0.0009847800 (mmBtu/scf)
June28357511 (scf/month)0.0009846300 (mmBtu/scf)
July28293745 (scf/month)0.0009851600 (mmBtu/scf)
August29221947 (scf/month)0.0009849500 (mmBtu/scf)
September26645420 (scf/month)0.0009847800 (mmBtu/scf)
October31031806 (scf/month)0.0009857500 (mmBtu/scf)
November35635420 (scf/month)0.0009848500 (mmBtu/scf)
December33861494 (scf/month)0.0009856000 (mmBtu/scf)


Subpart W: Petroleum and Natural Gas Systems

Gas Information Details

Gas NameCarbon Dioxide
Gas Quantity120,538.1 (Metric Tons)
Own Result?

Gas NameMethane
Gas Quantity125.1 (Metric Tons)
Own Result?

Gas NameNitrous Oxide
Gas Quantity0.06 (Metric Tons)
Own Result?


SubpartWSummaryDetails:
Industry Segment Number3
Industry Segment NameOnshore natural gas processing [98.230(a)(3)]
Total Reported CO2 Emissions (mt CO2)120538.1
Total CO2e Emissions (mt CO2e)123683.4
Total Reported CH4 Emissions (mt CH4)125.10
Total Reported N2O Emissions (mt N2O)0.060


SubpartWSourceReportingFormRowDetails:
Source Reporting FormOnshore Production [98.236(aa)(1)]
Required for Selected Industry SegmentNo
Source Reporting FormFacility Overview [98.236(aa)(2-11)]
Required for Selected Industry SegmentYes
Source Reporting FormNatural Gas Pneumatic Devices [98.236(b)]
Required for Selected Industry SegmentNo
Total Reported CO2 Emissions (mt CO2)0.0
Total Reported CH4 Emissions (mt CH4)0.00
Source Reporting FormNatural Gas Driven Pneumatic Pumps [98.236(c)]
Required for Selected Industry SegmentNo
Total Reported CO2 Emissions (mt CO2)0.0
Total Reported CH4 Emissions (mt CH4)0.00
Source Reporting FormAcid Gas Removal Units [98.236(d)]
Required for Selected Industry SegmentYes
Total Reported CO2 Emissions (mt CO2)98357.9
Source Reporting FormDehydrators [98.236(e)]
Required for Selected Industry SegmentYes
Total Reported CO2 Emissions (mt CO2)510.7
Total Reported CH4 Emissions (mt CH4)0.30
Total Reported N2O Emissions (mt N2O)0.000
Source Reporting FormWell Venting for Liquids Unloading [98.236(f)]
Required for Selected Industry SegmentNo
Total Reported CO2 Emissions (mt CO2)0.0
Total Reported CH4 Emissions (mt CH4)0.00
Source Reporting FormCompletions and Workovers with Hydraulic Fracturing [98.236(g)]
Required for Selected Industry SegmentNo
Total Reported CO2 Emissions (mt CO2)0.0
Total Reported CH4 Emissions (mt CH4)0.00
Total Reported N2O Emissions (mt N2O)0.000
Source Reporting FormCompletions and Workovers without Hydraulic Fracturing [98.236(h)]
Required for Selected Industry SegmentNo
Total Reported CO2 Emissions (mt CO2)0.0
Total Reported CH4 Emissions (mt CH4)0.00
Total Reported N2O Emissions (mt N2O)0.000
Source Reporting FormBlowdown Vent Stacks [98.236(i)]
Required for Selected Industry SegmentYes
Total Reported CO2 Emissions (mt CO2)0.0
Total Reported CH4 Emissions (mt CH4)0.00
Source Reporting FormAtmospheric Storage Tanks [98.236(j)]
Required for Selected Industry SegmentNo
Total Reported CO2 Emissions (mt CO2)0.0
Total Reported CH4 Emissions (mt CH4)0.00
Total Reported N2O Emissions (mt N2O)0.000
Source Reporting FormTransmission Storage Tanks [98.236(k)]
Required for Selected Industry SegmentNo
Total Reported CO2 Emissions (mt CO2)0.0
Total Reported CH4 Emissions (mt CH4)0.00
Total Reported N2O Emissions (mt N2O)0.000
Source Reporting FormWell Testing [98.236(l)]
Required for Selected Industry SegmentNo
Total Reported CO2 Emissions (mt CO2)0.0
Total Reported CH4 Emissions (mt CH4)0.00
Total Reported N2O Emissions (mt N2O)0.000
Source Reporting FormAssociated Gas Venting and Flaring [98.236(m)]
Required for Selected Industry SegmentNo
Total Reported CO2 Emissions (mt CO2)0.0
Total Reported CH4 Emissions (mt CH4)0.00
Total Reported N2O Emissions (mt N2O)0.000
Source Reporting FormFlare Stacks [98.236(n)]
Required for Selected Industry SegmentYes
Total Reported CO2 Emissions (mt CO2)21668.9
Total Reported CH4 Emissions (mt CH4)124.16
Total Reported N2O Emissions (mt N2O)0.060
Source Reporting FormCentrifugal Compressors [98.236(o)]
Required for Selected Industry SegmentYes
Total Reported CO2 Emissions (mt CO2)0.0
Total Reported CH4 Emissions (mt CH4)0.00
Source Reporting FormReciprocating Compressors [98.236(p)]
Required for Selected Industry SegmentYes
Total Reported CO2 Emissions (mt CO2)0.0
Total Reported CH4 Emissions (mt CH4)0.00
Source Reporting FormEquipment Leaks Surveys and Population Counts [98.236(q,r)]
Required for Selected Industry SegmentYes
Total Reported CO2 Emissions (mt CO2)0.5
Total Reported CH4 Emissions (mt CH4)0.64
Source Reporting FormOffshore Petroleum and Natural Gas Production [98.236(s)]
Required for Selected Industry SegmentNo
Total Reported CO2 Emissions (mt CO2)0.0
Total Reported CH4 Emissions (mt CH4)0.00
Total Reported N2O Emissions (mt N2O)0.000
Source Reporting FormEnhanced Oil Recovery Injection Pumps [98.236(w)]
Required for Selected Industry SegmentNo
Total Reported CO2 Emissions (mt CO2)0.0
Source Reporting FormEnhanced Oil Recovery Hydrocarbon Liquids [98.236(x)]
Required for Selected Industry SegmentNo
Total Reported CO2 Emissions (mt CO2)0.0
Source Reporting FormCombustion Equipment at Onshore Petroleum and Natural Gas Production Facilities, Onshore Petroleum and Natural Gas Gathering and Boosting Facilities, and Natural gas Distribution Facilities [98.236(z)]
Required for Selected Industry SegmentNo
Total Reported CO2 Emissions (mt CO2)0.0
Total Reported CH4 Emissions (mt CH4)0.00
Total Reported N2O Emissions (mt N2O)0.000


FacilityOverviewDetails:


FacilityOverviewNaturalGasProcessingRowDetails:
Average mole fraction of CH4 in natural gas received [98.236(aa)(3)(v)]0.666129
Average mole fraction of CO2 in natural gas received [98.236(aa)(3)(vi)]0.195475
Does the facility fractionate NGLs? [98.236(aa)(3)(vii)]No


AcidGasRemovalUnitsDetails:
mt CO298357.9
Did the Facility have any acid gas removal units that vent directly to the atmosphere, to a flare or engine, or to a sulfur recovery plant subject to reporting under 98.232 [98.236(d)]?Yes
Were missing data procedures used for any parameters to calculate GHG emissions? [98.235]No


AcidGasInfoRowDetails:
Unit ID or Name [98.236(d)(1)(i)]AGR 2
Total feed rate entering the acid gas removal unit for the year (million cubic feet) [98.236(d)(1)(ii)]17665.3643875
Calculation Method Used (Select from list) [98.236(d)(1)(iii)]Calculation Methodology 2 [98.233(d)(2)]
Are any CO2 emissions from the acid gas removal unit recovered and transferred outside the facility? (Yes / No) [98.236(d)(1)(iv)]Yes
Total CO2 Emissions (mt CO2) [98.236(d)(1)(v)]37972.2821125
Unit ID or Name [98.236(d)(1)(i)]AGR 3
Total feed rate entering the acid gas removal unit for the year (million cubic feet) [98.236(d)(1)(ii)]39913.3595068
Calculation Method Used (Select from list) [98.236(d)(1)(iii)]Calculation Methodology 2 [98.233(d)(2)]
Are any CO2 emissions from the acid gas removal unit recovered and transferred outside the facility? (Yes / No) [98.236(d)(1)(iv)]Yes
Total CO2 Emissions (mt CO2) [98.236(d)(1)(v)]60385.6373515


AcidGasCalcMethod2EmissionsRowDetails:
Unit ID or Name [98.236(d)(1)(i)]AGR 2
Annual average fraction of CO2 content in the vent from the acid gas removal unit, VolCO2 (volumetric fraction) [98.236(d)(2)(i)(A)]0.997
Annual volume of gas vented from the acid gas removal unit, Vs (actual or standard cubic feet) [98.236(d)(2)(i)(B)]730807442.7876973
Annual volume of gas vented reported on an Actual or Standard basis? [98.236]Standard
Temperature used to calculate volume of gas vented (°F) [98.236]60
Pressure used to calculate volume of gas vented (psi) [98.236]14.7
Unit ID or Name [98.236(d)(1)(i)]AGR 3
Annual average fraction of CO2 content in the vent from the acid gas removal unit, VolCO2 (volumetric fraction) [98.236(d)(2)(i)(A)]0.997
Annual volume of gas vented from the acid gas removal unit, Vs (actual or standard cubic feet) [98.236(d)(2)(i)(B)]1162170687.6418734
Annual volume of gas vented reported on an Actual or Standard basis? [98.236]Standard
Temperature used to calculate volume of gas vented (°F) [98.236]60
Pressure used to calculate volume of gas vented (psi) [98.236]14.7


DehydratorsDetails:
mt CO2510.7
mt CH40.30
mt N2O0.000
Did the facility have any glycol dehydrators with annual average daily natural gas throughputs greater than or equal to 0.4MMscfd subject to reporting under 98.232 [98.236(e)]?Yes
Did the facility have any glycol dehydrators with annual average daily natural gas throughputs less than 0.4MMscfd subject to reporting under 98.232 [98.236(e)]?No
Did the facility have any desiccant dehydrators subject to reporting under 98.232 [98.236(e)]?No
Were missing data procedures used for any parameters to calculate GHG emissions? [98.235]No


SmallGlycolDehydrators:
Emissions vented to flare or regenerator firebox/fire tubes
Emissions that were not vented to a flare or regenerator firebox/fire tubes


DessicantDehydrators:
Emissions vented to flare or regenerator firebox/fire tubes
Emissions that were not vented to a flare or regenerator firebox/fire tubes


GlycolDehydratorsMoreThanSpecifiedValueRowDetails:
Unit ID or Name [98.236(e)(1)(i)]CO2 Sales Dehydrator
Glycol dehydrator feed natural gas flow rate determined by engineering estimate based on best available data (MMscfd) [98.236(e)(1)(ii)]26.8
Dehydrator feed natural gas water content (pounds per MMscf) [98.236(e)(1)(iii)]110
Dehydrator outlet natural gas water content (pounds per MMscf) [98.236(e)(1)(iv)]13.8
Glycol dehydrator absorbent circulation pump type [98.236(e)(1)(v)]Electric
Dehydrator absorbent circulation rate (gallons per minute) [98.236(e)(1)(vi)]15
Report type of absorbent used [98.236(e)(1)(vii)]Triethylene glycol (TEG)
Report whether stripper gas is used in glycol dehydrator [98.236(e)(1)(viii)]No
Report whether a flash tank separator is used in glycol dehydrator [98.236(e)(1)(ix)]Yes
Total time the glycol dehydrator is operating (hours) [98.236(e)(1)(x)]7824
Temperature of the wet natural gas (°F) [98.236(e)(1)(xi)]76.6
Pressure of the wet natural gas (psig) [98.236(e)(1)(xii)]389
Concentration of CO2 in wet natural gas (mole fraction) [98.236(e)(1)(xiv)]1
Concentration of CH4 in wet natural gas (mole fraction) [98.236(e)(1)(xiii)]0
Were any dehydrator emissions vented to a vapor recovery device? [98.236(e)(1)(xv)]No
Were any dehydrator emissions vented to a flare or regenerator firebox/fire tubes? [98.236(e)(1)(xvi)]No
Were any dehydrator emissions vented to the atmosphere without being routed to a flare or regenerator firebox/fire tubes? [98.236(e)(1)(xvii)]Yes
CO2 Emissions from Venting (mt CO2) [98.236(e)(1)(xvii)(A)]510.7
CH4 Emissions from Venting (mt CH4) [98.236(e)(1)(xvii)(B)]0.3


BlowdownVentStacksDetails:
mt CO20.0
mt CH40.00
Did the facility have any blowdown vent stacks subject to reporting under 98.232 [98.236(i)]?No


FlareStacksDetails:
mt CO221668.9
mt CH4124.16
mt N2O0.060
Did the facility have flare stacks subject to reporting under 98.232 [98.236(n)]?Yes
Were missing data procedures used for any parameters to calculate GHG emissions? [98.235]No


UniqueFlareStacksRowDetails:
Unique Name or ID Number for the Flare Stack [98.236(n)(1)]Flare H-5201
Does the flare stack have a continuous flow monitor on gas to the flare? [98.236(n)(2)]Yes
Does the flare stack have a continuous gas analyzer on gas to the flare? [98.236(n)(3)]No
Were CEMS used to measure CO2 emissions for the flare stack? [98.233(n)(8)] [98.236(n)(12)]No
Volume of gas sent to flare, Vs (standard cubic feet) [98.236(n)(4)]75237397.9392693
Flare combustion efficiency (decimal value) [98.236(n)(6)]0.98
Mole fraction of CH4 in flare feed gas, XCH4 [98.236(n)(7)]0.66
Mole fraction of CO2 in flare feed gas, XCO2 [98.236(n)(8)]0.19
Fraction of feed gas sent to un-lit flare, Zu [98.236(n)(5)]0
CO2 emissions (mt CO2) [98.236(n)(9)]3358.7692721
CH4 Emissions (mt CH4) (Eq. W-19) [98.236(n)(10)]19.2452401
N2O Emissions (mt N2O) (Eq. W-40) [98.236(n)(11)]0.0092918
Unique Name or ID Number for the Flare Stack [98.236(n)(1)]Flare H-5301-3
Does the flare stack have a continuous flow monitor on gas to the flare? [98.236(n)(2)]Yes
Does the flare stack have a continuous gas analyzer on gas to the flare? [98.236(n)(3)]No
Were CEMS used to measure CO2 emissions for the flare stack? [98.233(n)(8)] [98.236(n)(12)]No
Volume of gas sent to flare, Vs (standard cubic feet) [98.236(n)(4)]410152123.6339582
Flare combustion efficiency (decimal value) [98.236(n)(6)]0.98
Mole fraction of CH4 in flare feed gas, XCH4 [98.236(n)(7)]0.66
Mole fraction of CO2 in flare feed gas, XCO2 [98.236(n)(8)]0.19
Fraction of feed gas sent to un-lit flare, Zu [98.236(n)(5)]0
CO2 emissions (mt CO2) [98.236(n)(9)]18310.1275094
CH4 Emissions (mt CH4) (Eq. W-19) [98.236(n)(10)]104.914262
N2O Emissions (mt N2O) (Eq. W-40) [98.236(n)(11)]0.0506538


CentrifugalCompressorsDetails:
mt CO20.0
mt CH40.00
Did the facility have any centrifugal compressors subject to reporting under 98.232 [98.236(o)]?No


ReciprocatingCompressorsDetails:
mt CO20.0
mt CH40.00
Did the facility have any reciprocating compressors subject to reporting under 98.232 [98.236(p)]?No


OtherEmissionsFromEquipmentLeaksDetails:
mt CO20.5
mt CH40.64
Did this facility use leak surveys to calculate emissions from equipment leaks in accordance with 98.232 [per 98.236(q)]?Yes
Were missing data procedures used for any parameters to calculate GHG emissions? [98.235]No
Number of complete equipment leak surveys performed during the calendar year [98.236(q)(1)(i)]1
Optical gas imaging instrument as specified in §60.18 [98.234(a)(1)]Yes
Method 21 [98.234(a)(2)]No
Infrared laser beam illuminated instrument [98.234(a)(3)]No
Acoustic leak detection device [98.234(a)(5)]No
Optical gas imaging instrument as specified in §60.5397a [98.234(a)(6)]No
Method 21 as specified in §60.5397a [98.234(a)(7)]No


GasProcessingEmissionsFactorsRowDetails:
Component Type [98.236(q)(2)(i)]Compressor Components, Gas Service - Valve
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)]0
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)]0
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)]0
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)]0
Component Type [98.236(q)(2)(i)]Compressor Components, Gas Service - Connector
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)]0
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)]0
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)]0
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)]0
Component Type [98.236(q)(2)(i)]Compressor Components, Gas Service - Open-ended Line
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)]0
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)]0
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)]0
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)]0
Component Type [98.236(q)(2)(i)]Compressor Components, Gas Service - Pressure Relief Valve
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)]0
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)]0
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)]0
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)]0
Component Type [98.236(q)(2)(i)]Compressor Components, Gas Service - Meter
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)]0
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)]0
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)]0
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)]0
Component Type [98.236(q)(2)(i)]Non-Compressor Components, Gas Service - Valve
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)]0
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)]0
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)]0
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)]0
Component Type [98.236(q)(2)(i)]Non-Compressor Components, Gas Service - Connector
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)]1
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)]8760
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)]0.54
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)]0.64
Component Type [98.236(q)(2)(i)]Non-Compressor Components, Gas Service - Open-ended Line
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)]0
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)]0
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)]0
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)]0
Component Type [98.236(q)(2)(i)]Non-Compressor components, Gas Service - Pressure Relief Valve
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)]0
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)]0
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)]0
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)]0
Component Type [98.236(q)(2)(i)]Non-Compressor components, Gas Service - Meter
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)]0
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)]0
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)]0
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)]0


Subpart PP: Suppliers of Carbon Dioxide

Gas Information Details

Gas NameCarbon Dioxide
Gas Quantity
Own Result?

Supplier Type: capture 98.420(a)(1)
Calculation Methodology: Flow Meters 2

Meter Details:

Meter Name: FIQY-7300
Meter Description:
Meter Type: CO2 Flow Meter
Measurement Type: Volumetric - concentration in volume percentage
Annual Mass of CO2 (Metric Tons):
Biomass-Based Percent: 0
Flow Meter Location: UpStream
Was CO2 Imported or Exported: NA
Dehydration Equipment Upstream? Y
Dehydration Equipment Downstream? N
Compression Equipment Upstream? Y
Compression Equipment Downstream? N
Other Processing Equipment Upstream? N
Other Processing Equipment Downstream? N
Other Processing Equipment Description: NA

Quarterly Volumetric Flow Data
QuarterVolumetric Flow RateCO2 ConcentrationMeasurement StandardDensity
First Quarter (volume %CO2 expressed as a fraction) Gas chromatography (mton/scm)
Second Quarter (volume %CO2 expressed as a fraction) Gas chromatography (mton/scm)
Third Quarter (volume %CO2 expressed as a fraction) Gas chromatography (mton/scm)
Fourth Quarter (volume %CO2 expressed as a fraction) Gas chromatography (mton/scm)


End Use Details
End Use CategoryQuantity of CO2
Food and beverage (Metric Tons)
Industrial and municipal water/wastewater treatment (Metric Tons)
Metal fabrication, including welding and cutting (Metric Tons)
Greenhouse uses for plant growth (Metric Tons)
Fumigants (e.g., grain storage) and herbicides (Metric Tons)
Pulp and paper (Metric Tons)
Cleaning and solvent use (Metric Tons)
Fire fighting (Metric Tons)
Transportation and storage of explosives (Metric Tons)
Injection of CO2 for enhanced oil and natural gas recovery that is covered by 40 CFR Part 98, Subpart UU (Metric Tons)
Geologic sequestration of carbon dioxide that is covered by 40 CFR Part 98, Subpart RR (Metric Tons)
Research and Development (Metric Tons)
Other (if other please provide a short description of the use) (Metric Tons)
Unknown (Metric Tons)

Number of days substitute data procedures were used for mass or volume: 0
Number of days substitute data procedures were used for concentration: 0
Number of days substitute data procedures were used for density: 0

Types of Equipment Used
Equipment TypeStandard Used to Calibrate Equipment
Volumetric flow meterManufacturers recommended guidelines.