Source Reporting Form | Onshore Production [98.236(aa)(1)] |
Required for Selected Industry Segment | No |
Source Reporting Form | Facility Overview [98.236(aa)(2-11)] |
Required for Selected Industry Segment | Yes |
Source Reporting Form | Natural Gas Pneumatic Devices [98.236(b)] |
Required for Selected Industry Segment | Yes |
Total Reported CO2 Emissions (mt CO2) | 3.0 |
Total Reported CH4 Emissions (mt CH4) | 418.16 |
Source Reporting Form | Natural Gas Driven Pneumatic Pumps [98.236(c)] |
Required for Selected Industry Segment | Yes |
Total Reported CO2 Emissions (mt CO2) | 0.6 |
Total Reported CH4 Emissions (mt CH4) | 88.48 |
Source Reporting Form | Acid Gas Removal Units [98.236(d)] |
Required for Selected Industry Segment | Yes |
Total Reported CO2 Emissions (mt CO2) | 0.0 |
Source Reporting Form | Dehydrators [98.236(e)] |
Required for Selected Industry Segment | Yes |
Total Reported CO2 Emissions (mt CO2) | 908.3 |
Total Reported CH4 Emissions (mt CH4) | 7.82 |
Total Reported N2O Emissions (mt N2O) | 0.001 |
Source Reporting Form | Well Venting for Liquids Unloading [98.236(f)] |
Required for Selected Industry Segment | No |
Total Reported CO2 Emissions (mt CO2) | 0.0 |
Total Reported CH4 Emissions (mt CH4) | 0.00 |
Source Reporting Form | Completions and Workovers with Hydraulic Fracturing [98.236(g)] |
Required for Selected Industry Segment | No |
Total Reported CO2 Emissions (mt CO2) | 0.0 |
Total Reported CH4 Emissions (mt CH4) | 0.00 |
Total Reported N2O Emissions (mt N2O) | 0.000 |
Source Reporting Form | Completions and Workovers without Hydraulic Fracturing [98.236(h)] |
Required for Selected Industry Segment | No |
Total Reported CO2 Emissions (mt CO2) | 0.0 |
Total Reported CH4 Emissions (mt CH4) | 0.00 |
Total Reported N2O Emissions (mt N2O) | 0.000 |
Source Reporting Form | Blowdown Vent Stacks [98.236(i)] |
Required for Selected Industry Segment | Yes |
Total Reported CO2 Emissions (mt CO2) | 0.2 |
Total Reported CH4 Emissions (mt CH4) | 54.64 |
Source Reporting Form | Atmospheric Storage Tanks [98.236(j)] |
Required for Selected Industry Segment | Yes |
Total Reported CO2 Emissions (mt CO2) | 230.1 |
Total Reported CH4 Emissions (mt CH4) | 5.73 |
Total Reported N2O Emissions (mt N2O) | 0.000 |
Source Reporting Form | Transmission Storage Tanks [98.236(k)] |
Required for Selected Industry Segment | No |
Total Reported CO2 Emissions (mt CO2) | 0.0 |
Total Reported CH4 Emissions (mt CH4) | 0.00 |
Total Reported N2O Emissions (mt N2O) | 0.000 |
Source Reporting Form | Well Testing [98.236(l)] |
Required for Selected Industry Segment | No |
Total Reported CO2 Emissions (mt CO2) | 0.0 |
Total Reported CH4 Emissions (mt CH4) | 0.00 |
Total Reported N2O Emissions (mt N2O) | 0.000 |
Source Reporting Form | Associated Gas Venting and Flaring [98.236(m)] |
Required for Selected Industry Segment | No |
Total Reported CO2 Emissions (mt CO2) | 0.0 |
Total Reported CH4 Emissions (mt CH4) | 0.00 |
Total Reported N2O Emissions (mt N2O) | 0.000 |
Source Reporting Form | Flare Stacks [98.236(n)] |
Required for Selected Industry Segment | Yes |
Total Reported CO2 Emissions (mt CO2) | 2844.5 |
Total Reported CH4 Emissions (mt CH4) | 28.94 |
Total Reported N2O Emissions (mt N2O) | 0.005 |
Source Reporting Form | Centrifugal Compressors [98.236(o)] |
Required for Selected Industry Segment | Yes |
Total Reported CO2 Emissions (mt CO2) | 0.0 |
Total Reported CH4 Emissions (mt CH4) | 0.00 |
Source Reporting Form | Reciprocating Compressors [98.236(p)] |
Required for Selected Industry Segment | Yes |
Total Reported CO2 Emissions (mt CO2) | 1.5 |
Total Reported CH4 Emissions (mt CH4) | 9.55 |
Source Reporting Form | Equipment Leaks Surveys and Population Counts [98.236(q,r)] |
Required for Selected Industry Segment | Yes |
Total Reported CO2 Emissions (mt CO2) | 1.6 |
Total Reported CH4 Emissions (mt CH4) | 270.78 |
Source Reporting Form | Offshore Petroleum and Natural Gas Production [98.236(s)] |
Required for Selected Industry Segment | No |
Total Reported CO2 Emissions (mt CO2) | 0.0 |
Total Reported CH4 Emissions (mt CH4) | 0.00 |
Total Reported N2O Emissions (mt N2O) | 0.000 |
Source Reporting Form | Enhanced Oil Recovery Injection Pumps [98.236(w)] |
Required for Selected Industry Segment | No |
Total Reported CO2 Emissions (mt CO2) | 0.0 |
Source Reporting Form | Enhanced Oil Recovery Hydrocarbon Liquids [98.236(x)] |
Required for Selected Industry Segment | No |
Total Reported CO2 Emissions (mt CO2) | 0.0 |
Source Reporting Form | Combustion Equipment at Onshore Petroleum and Natural Gas Production Facilities, Onshore Petroleum and Natural Gas Gathering and Boosting Facilities, and Natural gas Distribution Facilities [98.236(z)] |
Required for Selected Industry Segment | Yes |
Total Reported CO2 Emissions (mt CO2) | 280649.0 |
Total Reported CH4 Emissions (mt CH4) | 8.60 |
Total Reported N2O Emissions (mt N2O) | 0.529 |
Unit ID or Name [98.236(e)(1)(i)] | Plant 1 Dehy-F176 |
County and State [98.236(e)(1)(xviii)] | EDDY, NM |
Glycol dehydrator feed natural gas flow rate determined by engineering estimate based on best available data (MMscfd) [98.236(e)(1)(ii)] | 10.01 |
Dehydrator feed natural gas water content (pounds per MMscf) [98.236(e)(1)(iii)] | 59.97 |
Dehydrator outlet natural gas water content (pounds per MMscf) [98.236(e)(1)(iv)] | 5.89 |
Glycol dehydrator absorbent circulation pump type [98.236(e)(1)(v)] | Natural gas pneumatic |
Dehydrator absorbent circulation rate (gallons per minute) [98.236(e)(1)(vi)] | 0.77 |
Report type of absorbent used [98.236(e)(1)(vii)] | Triethylene glycol (TEG) |
Report whether stripper gas is used in glycol dehydrator [98.236(e)(1)(viii)] | No |
Report whether a flash tank separator is used in glycol dehydrator [98.236(e)(1)(ix)] | Yes |
Total time the glycol dehydrator is operating (hours) [98.236(e)(1)(x)] | 8760 |
Temperature of the wet natural gas (°F) [98.236(e)(1)(xi)] | 100 |
Pressure of the wet natural gas (psig) [98.236(e)(1)(xii)] | 989.7 |
Concentration of CO2 in wet natural gas (mole fraction) [98.236(e)(1)(xiv)] | 0.00184 |
Concentration of CH4 in wet natural gas (mole fraction) [98.236(e)(1)(xiii)] | 0.778 |
Were any dehydrator emissions vented to a vapor recovery device? [98.236(e)(1)(xv)] | Yes |
Were any dehydrator emissions vented to a flare or regenerator firebox/fire tubes? [98.236(e)(1)(xvi)] | Yes |
CO2 Emissions from Flares or Regenerators (mt CO2) [98.236(e)(1)(xvi)(A)] | 8.12771 |
CH4 Emissions from Flares or Regenerators (mt CH4) [98.236(e)(1)(xvi)(B)] | 0.0052 |
N2O Emissions from Flares or Regenerators (mt N2O) [98.236(e)(1)(xvi)(C)] | 0 |
Were any dehydrator emissions vented to the atmosphere without being routed to a flare or regenerator firebox/fire tubes? [98.236(e)(1)(xvii)] | No |
Unit ID or Name [98.236(e)(1)(i)] | Orla Express Dehy-F176 |
County and State [98.236(e)(1)(xviii)] | EDDY, NM |
Glycol dehydrator feed natural gas flow rate determined by engineering estimate based on best available data (MMscfd) [98.236(e)(1)(ii)] | 55.34 |
Dehydrator feed natural gas water content (pounds per MMscf) [98.236(e)(1)(iii)] | 59.97 |
Dehydrator outlet natural gas water content (pounds per MMscf) [98.236(e)(1)(iv)] | 7 |
Glycol dehydrator absorbent circulation pump type [98.236(e)(1)(v)] | Natural gas pneumatic |
Dehydrator absorbent circulation rate (gallons per minute) [98.236(e)(1)(vi)] | 2.79 |
Report type of absorbent used [98.236(e)(1)(vii)] | Triethylene glycol (TEG) |
Report whether stripper gas is used in glycol dehydrator [98.236(e)(1)(viii)] | No |
Report whether a flash tank separator is used in glycol dehydrator [98.236(e)(1)(ix)] | Yes |
Total time the glycol dehydrator is operating (hours) [98.236(e)(1)(x)] | 8760 |
Temperature of the wet natural gas (°F) [98.236(e)(1)(xi)] | 100 |
Pressure of the wet natural gas (psig) [98.236(e)(1)(xii)] | 989.7 |
Concentration of CO2 in wet natural gas (mole fraction) [98.236(e)(1)(xiv)] | 0.00184 |
Concentration of CH4 in wet natural gas (mole fraction) [98.236(e)(1)(xiii)] | 0.778 |
Were any dehydrator emissions vented to a vapor recovery device? [98.236(e)(1)(xv)] | Yes |
Were any dehydrator emissions vented to a flare or regenerator firebox/fire tubes? [98.236(e)(1)(xvi)] | Yes |
CO2 Emissions from Flares or Regenerators (mt CO2) [98.236(e)(1)(xvi)(A)] | 27.9027 |
CH4 Emissions from Flares or Regenerators (mt CH4) [98.236(e)(1)(xvi)(B)] | 0.01825 |
N2O Emissions from Flares or Regenerators (mt N2O) [98.236(e)(1)(xvi)(C)] | 0 |
Were any dehydrator emissions vented to the atmosphere without being routed to a flare or regenerator firebox/fire tubes? [98.236(e)(1)(xvii)] | No |
Unit ID or Name [98.236(e)(1)(i)] | Dehy-F176 |
County and State [98.236(e)(1)(xviii)] | EDDY, NM |
Glycol dehydrator feed natural gas flow rate determined by engineering estimate based on best available data (MMscfd) [98.236(e)(1)(ii)] | 6.96 |
Dehydrator feed natural gas water content (pounds per MMscf) [98.236(e)(1)(iii)] | 57.44 |
Dehydrator outlet natural gas water content (pounds per MMscf) [98.236(e)(1)(iv)] | 3.66 |
Glycol dehydrator absorbent circulation pump type [98.236(e)(1)(v)] | Natural gas pneumatic |
Dehydrator absorbent circulation rate (gallons per minute) [98.236(e)(1)(vi)] | 7 |
Report type of absorbent used [98.236(e)(1)(vii)] | Triethylene glycol (TEG) |
Report whether stripper gas is used in glycol dehydrator [98.236(e)(1)(viii)] | No |
Report whether a flash tank separator is used in glycol dehydrator [98.236(e)(1)(ix)] | Yes |
Total time the glycol dehydrator is operating (hours) [98.236(e)(1)(x)] | 1224 |
Temperature of the wet natural gas (°F) [98.236(e)(1)(xi)] | 99.01 |
Pressure of the wet natural gas (psig) [98.236(e)(1)(xii)] | 1009.4 |
Concentration of CO2 in wet natural gas (mole fraction) [98.236(e)(1)(xiv)] | 0.00215 |
Concentration of CH4 in wet natural gas (mole fraction) [98.236(e)(1)(xiii)] | 0.781 |
Were any dehydrator emissions vented to a vapor recovery device? [98.236(e)(1)(xv)] | Yes |
Were any dehydrator emissions vented to a flare or regenerator firebox/fire tubes? [98.236(e)(1)(xvi)] | Yes |
CO2 Emissions from Flares or Regenerators (mt CO2) [98.236(e)(1)(xvi)(A)] | 18.10653 |
CH4 Emissions from Flares or Regenerators (mt CH4) [98.236(e)(1)(xvi)(B)] | 0.00609 |
N2O Emissions from Flares or Regenerators (mt N2O) [98.236(e)(1)(xvi)(C)] | 0.00003 |
Were any dehydrator emissions vented to the atmosphere without being routed to a flare or regenerator firebox/fire tubes? [98.236(e)(1)(xvii)] | No |
Unit ID or Name [98.236(e)(1)(i)] | TEG Dehy. Unit #1-F399 |
County and State [98.236(e)(1)(xviii)] | EDDY, NM |
Glycol dehydrator feed natural gas flow rate determined by engineering estimate based on best available data (MMscfd) [98.236(e)(1)(ii)] | 0.12 |
Dehydrator feed natural gas water content (pounds per MMscf) [98.236(e)(1)(iii)] | 60.78 |
Dehydrator outlet natural gas water content (pounds per MMscf) [98.236(e)(1)(iv)] | 4.55 |
Glycol dehydrator absorbent circulation pump type [98.236(e)(1)(v)] | Natural gas pneumatic |
Dehydrator absorbent circulation rate (gallons per minute) [98.236(e)(1)(vi)] | 0.0448 |
Report type of absorbent used [98.236(e)(1)(vii)] | Triethylene glycol (TEG) |
Report whether stripper gas is used in glycol dehydrator [98.236(e)(1)(viii)] | No |
Report whether a flash tank separator is used in glycol dehydrator [98.236(e)(1)(ix)] | Yes |
Total time the glycol dehydrator is operating (hours) [98.236(e)(1)(x)] | 2880 |
Temperature of the wet natural gas (°F) [98.236(e)(1)(xi)] | 94 |
Pressure of the wet natural gas (psig) [98.236(e)(1)(xii)] | 764.7 |
Concentration of CO2 in wet natural gas (mole fraction) [98.236(e)(1)(xiv)] | 0.00129 |
Concentration of CH4 in wet natural gas (mole fraction) [98.236(e)(1)(xiii)] | 0.746 |
Were any dehydrator emissions vented to a vapor recovery device? [98.236(e)(1)(xv)] | No |
Were any dehydrator emissions vented to a flare or regenerator firebox/fire tubes? [98.236(e)(1)(xvi)] | Yes |
CO2 Emissions from Flares or Regenerators (mt CO2) [98.236(e)(1)(xvi)(A)] | 3.57031 |
CH4 Emissions from Flares or Regenerators (mt CH4) [98.236(e)(1)(xvi)(B)] | 0.03232 |
N2O Emissions from Flares or Regenerators (mt N2O) [98.236(e)(1)(xvi)(C)] | 0 |
Were any dehydrator emissions vented to the atmosphere without being routed to a flare or regenerator firebox/fire tubes? [98.236(e)(1)(xvii)] | No |
Unit ID or Name [98.236(e)(1)(i)] | D1-F404 |
County and State [98.236(e)(1)(xviii)] | EDDY, NM |
Glycol dehydrator feed natural gas flow rate determined by engineering estimate based on best available data (MMscfd) [98.236(e)(1)(ii)] | 22.6 |
Dehydrator feed natural gas water content (pounds per MMscf) [98.236(e)(1)(iii)] | 102.02 |
Dehydrator outlet natural gas water content (pounds per MMscf) [98.236(e)(1)(iv)] | 7 |
Glycol dehydrator absorbent circulation pump type [98.236(e)(1)(v)] | Natural gas pneumatic |
Dehydrator absorbent circulation rate (gallons per minute) [98.236(e)(1)(vi)] | 1.96 |
Report type of absorbent used [98.236(e)(1)(vii)] | Triethylene glycol (TEG) |
Report whether stripper gas is used in glycol dehydrator [98.236(e)(1)(viii)] | Yes |
Report whether a flash tank separator is used in glycol dehydrator [98.236(e)(1)(ix)] | Yes |
Total time the glycol dehydrator is operating (hours) [98.236(e)(1)(x)] | 8760 |
Temperature of the wet natural gas (°F) [98.236(e)(1)(xi)] | 120 |
Pressure of the wet natural gas (psig) [98.236(e)(1)(xii)] | 1014.7 |
Concentration of CO2 in wet natural gas (mole fraction) [98.236(e)(1)(xiv)] | 0.00136 |
Concentration of CH4 in wet natural gas (mole fraction) [98.236(e)(1)(xiii)] | 0.754 |
Were any dehydrator emissions vented to a vapor recovery device? [98.236(e)(1)(xv)] | No |
Were any dehydrator emissions vented to a flare or regenerator firebox/fire tubes? [98.236(e)(1)(xvi)] | Yes |
CO2 Emissions from Flares or Regenerators (mt CO2) [98.236(e)(1)(xvi)(A)] | 601.13322 |
CH4 Emissions from Flares or Regenerators (mt CH4) [98.236(e)(1)(xvi)(B)] | 2.14818 |
N2O Emissions from Flares or Regenerators (mt N2O) [98.236(e)(1)(xvi)(C)] | 0.00107 |
Were any dehydrator emissions vented to the atmosphere without being routed to a flare or regenerator firebox/fire tubes? [98.236(e)(1)(xvii)] | No |
Unit ID or Name [98.236(e)(1)(i)] | DEHY1-F552 |
County and State [98.236(e)(1)(xviii)] | EDDY, NM |
Glycol dehydrator feed natural gas flow rate determined by engineering estimate based on best available data (MMscfd) [98.236(e)(1)(ii)] | 33.12 |
Dehydrator feed natural gas water content (pounds per MMscf) [98.236(e)(1)(iii)] | 68.01 |
Dehydrator outlet natural gas water content (pounds per MMscf) [98.236(e)(1)(iv)] | 3.2 |
Glycol dehydrator absorbent circulation pump type [98.236(e)(1)(v)] | Natural gas pneumatic |
Dehydrator absorbent circulation rate (gallons per minute) [98.236(e)(1)(vi)] | 14.3 |
Report type of absorbent used [98.236(e)(1)(vii)] | Triethylene glycol (TEG) |
Report whether stripper gas is used in glycol dehydrator [98.236(e)(1)(viii)] | No |
Report whether a flash tank separator is used in glycol dehydrator [98.236(e)(1)(ix)] | Yes |
Total time the glycol dehydrator is operating (hours) [98.236(e)(1)(x)] | 6720 |
Temperature of the wet natural gas (°F) [98.236(e)(1)(xi)] | 106 |
Pressure of the wet natural gas (psig) [98.236(e)(1)(xii)] | 1051.7 |
Concentration of CO2 in wet natural gas (mole fraction) [98.236(e)(1)(xiv)] | 0.00243 |
Concentration of CH4 in wet natural gas (mole fraction) [98.236(e)(1)(xiii)] | 0.788 |
Were any dehydrator emissions vented to a vapor recovery device? [98.236(e)(1)(xv)] | Yes |
Were any dehydrator emissions vented to a flare or regenerator firebox/fire tubes? [98.236(e)(1)(xvi)] | Yes |
CO2 Emissions from Flares or Regenerators (mt CO2) [98.236(e)(1)(xvi)(A)] | 118.66561 |
CH4 Emissions from Flares or Regenerators (mt CH4) [98.236(e)(1)(xvi)(B)] | 0.09653 |
N2O Emissions from Flares or Regenerators (mt N2O) [98.236(e)(1)(xvi)(C)] | 0.00018 |
Were any dehydrator emissions vented to the atmosphere without being routed to a flare or regenerator firebox/fire tubes? [98.236(e)(1)(xvii)] | No |
Unit ID or Name [98.236(e)(1)(i)] | DEHY2-F552 |
County and State [98.236(e)(1)(xviii)] | EDDY, NM |
Glycol dehydrator feed natural gas flow rate determined by engineering estimate based on best available data (MMscfd) [98.236(e)(1)(ii)] | 33.25 |
Dehydrator feed natural gas water content (pounds per MMscf) [98.236(e)(1)(iii)] | 68.01 |
Dehydrator outlet natural gas water content (pounds per MMscf) [98.236(e)(1)(iv)] | 3.03 |
Glycol dehydrator absorbent circulation pump type [98.236(e)(1)(v)] | Natural gas pneumatic |
Dehydrator absorbent circulation rate (gallons per minute) [98.236(e)(1)(vi)] | 16.8 |
Report type of absorbent used [98.236(e)(1)(vii)] | Triethylene glycol (TEG) |
Report whether stripper gas is used in glycol dehydrator [98.236(e)(1)(viii)] | No |
Report whether a flash tank separator is used in glycol dehydrator [98.236(e)(1)(ix)] | Yes |
Total time the glycol dehydrator is operating (hours) [98.236(e)(1)(x)] | 6720 |
Temperature of the wet natural gas (°F) [98.236(e)(1)(xi)] | 106 |
Pressure of the wet natural gas (psig) [98.236(e)(1)(xii)] | 1051.7 |
Concentration of CO2 in wet natural gas (mole fraction) [98.236(e)(1)(xiv)] | 0.00243 |
Concentration of CH4 in wet natural gas (mole fraction) [98.236(e)(1)(xiii)] | 0.788 |
Were any dehydrator emissions vented to a vapor recovery device? [98.236(e)(1)(xv)] | Yes |
Were any dehydrator emissions vented to a flare or regenerator firebox/fire tubes? [98.236(e)(1)(xvi)] | Yes |
CO2 Emissions from Flares or Regenerators (mt CO2) [98.236(e)(1)(xvi)(A)] | 130.10462 |
CH4 Emissions from Flares or Regenerators (mt CH4) [98.236(e)(1)(xvi)(B)] | 0.10585 |
N2O Emissions from Flares or Regenerators (mt N2O) [98.236(e)(1)(xvi)(C)] | 0.00018 |
Were any dehydrator emissions vented to the atmosphere without being routed to a flare or regenerator firebox/fire tubes? [98.236(e)(1)(xvii)] | No |
Unit ID or Name [98.236(e)(1)(i)] | 6-DHY-1-F553 |
County and State [98.236(e)(1)(xviii)] | EDDY, NM |
Glycol dehydrator feed natural gas flow rate determined by engineering estimate based on best available data (MMscfd) [98.236(e)(1)(ii)] | 22.57 |
Dehydrator feed natural gas water content (pounds per MMscf) [98.236(e)(1)(iii)] | 74.97 |
Dehydrator outlet natural gas water content (pounds per MMscf) [98.236(e)(1)(iv)] | 7 |
Glycol dehydrator absorbent circulation pump type [98.236(e)(1)(v)] | Natural gas pneumatic |
Dehydrator absorbent circulation rate (gallons per minute) [98.236(e)(1)(vi)] | 2.21 |
Report type of absorbent used [98.236(e)(1)(vii)] | Triethylene glycol (TEG) |
Report whether stripper gas is used in glycol dehydrator [98.236(e)(1)(viii)] | No |
Report whether a flash tank separator is used in glycol dehydrator [98.236(e)(1)(ix)] | Yes |
Total time the glycol dehydrator is operating (hours) [98.236(e)(1)(x)] | 8760 |
Temperature of the wet natural gas (°F) [98.236(e)(1)(xi)] | 108.47 |
Pressure of the wet natural gas (psig) [98.236(e)(1)(xii)] | 1009.7 |
Concentration of CO2 in wet natural gas (mole fraction) [98.236(e)(1)(xiv)] | 0.000709 |
Concentration of CH4 in wet natural gas (mole fraction) [98.236(e)(1)(xiii)] | 0.791 |
Were any dehydrator emissions vented to a vapor recovery device? [98.236(e)(1)(xv)] | No |
Were any dehydrator emissions vented to a flare or regenerator firebox/fire tubes? [98.236(e)(1)(xvi)] | No |
Were any dehydrator emissions vented to the atmosphere without being routed to a flare or regenerator firebox/fire tubes? [98.236(e)(1)(xvii)] | Yes |
CO2 Emissions from Venting (mt CO2) [98.236(e)(1)(xvii)(A)] | 0.05169 |
CH4 Emissions from Venting (mt CH4) [98.236(e)(1)(xvii)(B)] | 0.82645 |
Unit ID or Name [98.236(e)(1)(i)] | 6-DHY-1-F554 |
County and State [98.236(e)(1)(xviii)] | EDDY, NM |
Glycol dehydrator feed natural gas flow rate determined by engineering estimate based on best available data (MMscfd) [98.236(e)(1)(ii)] | 25.66 |
Dehydrator feed natural gas water content (pounds per MMscf) [98.236(e)(1)(iii)] | 63.68 |
Dehydrator outlet natural gas water content (pounds per MMscf) [98.236(e)(1)(iv)] | 6.01 |
Glycol dehydrator absorbent circulation pump type [98.236(e)(1)(v)] | Natural gas pneumatic |
Dehydrator absorbent circulation rate (gallons per minute) [98.236(e)(1)(vi)] | 2.23 |
Report type of absorbent used [98.236(e)(1)(vii)] | Triethylene glycol (TEG) |
Report whether stripper gas is used in glycol dehydrator [98.236(e)(1)(viii)] | No |
Report whether a flash tank separator is used in glycol dehydrator [98.236(e)(1)(ix)] | Yes |
Total time the glycol dehydrator is operating (hours) [98.236(e)(1)(x)] | 8760 |
Temperature of the wet natural gas (°F) [98.236(e)(1)(xi)] | 101.29 |
Pressure of the wet natural gas (psig) [98.236(e)(1)(xii)] | 955.7 |
Concentration of CO2 in wet natural gas (mole fraction) [98.236(e)(1)(xiv)] | 0.00102 |
Concentration of CH4 in wet natural gas (mole fraction) [98.236(e)(1)(xiii)] | 0.766 |
Were any dehydrator emissions vented to a vapor recovery device? [98.236(e)(1)(xv)] | No |
Were any dehydrator emissions vented to a flare or regenerator firebox/fire tubes? [98.236(e)(1)(xvi)] | No |
Were any dehydrator emissions vented to the atmosphere without being routed to a flare or regenerator firebox/fire tubes? [98.236(e)(1)(xvii)] | Yes |
CO2 Emissions from Venting (mt CO2) [98.236(e)(1)(xvii)(A)] | 0.07593 |
CH4 Emissions from Venting (mt CH4) [98.236(e)(1)(xvii)(B)] | 0.81855 |
Unit ID or Name [98.236(e)(1)(i)] | 6-DHY-1-F555 |
County and State [98.236(e)(1)(xviii)] | EDDY, NM |
Glycol dehydrator feed natural gas flow rate determined by engineering estimate based on best available data (MMscfd) [98.236(e)(1)(ii)] | 28.86 |
Dehydrator feed natural gas water content (pounds per MMscf) [98.236(e)(1)(iii)] | 119.25 |
Dehydrator outlet natural gas water content (pounds per MMscf) [98.236(e)(1)(iv)] | 7 |
Glycol dehydrator absorbent circulation pump type [98.236(e)(1)(v)] | Natural gas pneumatic |
Dehydrator absorbent circulation rate (gallons per minute) [98.236(e)(1)(vi)] | 2.06 |
Report type of absorbent used [98.236(e)(1)(vii)] | Triethylene glycol (TEG) |
Report whether stripper gas is used in glycol dehydrator [98.236(e)(1)(viii)] | No |
Report whether a flash tank separator is used in glycol dehydrator [98.236(e)(1)(ix)] | Yes |
Total time the glycol dehydrator is operating (hours) [98.236(e)(1)(x)] | 8760 |
Temperature of the wet natural gas (°F) [98.236(e)(1)(xi)] | 125.78 |
Pressure of the wet natural gas (psig) [98.236(e)(1)(xii)] | 1007.7 |
Concentration of CO2 in wet natural gas (mole fraction) [98.236(e)(1)(xiv)] | 0.000968 |
Concentration of CH4 in wet natural gas (mole fraction) [98.236(e)(1)(xiii)] | 0.782 |
Were any dehydrator emissions vented to a vapor recovery device? [98.236(e)(1)(xv)] | No |
Were any dehydrator emissions vented to a flare or regenerator firebox/fire tubes? [98.236(e)(1)(xvi)] | No |
Were any dehydrator emissions vented to the atmosphere without being routed to a flare or regenerator firebox/fire tubes? [98.236(e)(1)(xvii)] | Yes |
CO2 Emissions from Venting (mt CO2) [98.236(e)(1)(xvii)(A)] | 0.05642 |
CH4 Emissions from Venting (mt CH4) [98.236(e)(1)(xvii)(B)] | 0.69536 |
Unit ID or Name [98.236(e)(1)(i)] | 7-DEHY-1-F556 |
County and State [98.236(e)(1)(xviii)] | EDDY, NM |
Glycol dehydrator feed natural gas flow rate determined by engineering estimate based on best available data (MMscfd) [98.236(e)(1)(ii)] | 39.03 |
Dehydrator feed natural gas water content (pounds per MMscf) [98.236(e)(1)(iii)] | 97.12 |
Dehydrator outlet natural gas water content (pounds per MMscf) [98.236(e)(1)(iv)] | 7 |
Glycol dehydrator absorbent circulation pump type [98.236(e)(1)(v)] | Natural gas pneumatic |
Dehydrator absorbent circulation rate (gallons per minute) [98.236(e)(1)(vi)] | 2.32 |
Report type of absorbent used [98.236(e)(1)(vii)] | Triethylene glycol (TEG) |
Report whether stripper gas is used in glycol dehydrator [98.236(e)(1)(viii)] | No |
Report whether a flash tank separator is used in glycol dehydrator [98.236(e)(1)(ix)] | Yes |
Total time the glycol dehydrator is operating (hours) [98.236(e)(1)(x)] | 8760 |
Temperature of the wet natural gas (°F) [98.236(e)(1)(xi)] | 116.62 |
Pressure of the wet natural gas (psig) [98.236(e)(1)(xii)] | 957.7 |
Concentration of CO2 in wet natural gas (mole fraction) [98.236(e)(1)(xiv)] | 0.00118 |
Concentration of CH4 in wet natural gas (mole fraction) [98.236(e)(1)(xiii)] | 0.762 |
Were any dehydrator emissions vented to a vapor recovery device? [98.236(e)(1)(xv)] | No |
Were any dehydrator emissions vented to a flare or regenerator firebox/fire tubes? [98.236(e)(1)(xvi)] | No |
Were any dehydrator emissions vented to the atmosphere without being routed to a flare or regenerator firebox/fire tubes? [98.236(e)(1)(xvii)] | Yes |
CO2 Emissions from Venting (mt CO2) [98.236(e)(1)(xvii)(A)] | 0.07947 |
CH4 Emissions from Venting (mt CH4) [98.236(e)(1)(xvii)(B)] | 0.77483 |
Unit ID or Name [98.236(e)(1)(i)] | 4-DHY-1-F558 |
County and State [98.236(e)(1)(xviii)] | EDDY, NM |
Glycol dehydrator feed natural gas flow rate determined by engineering estimate based on best available data (MMscfd) [98.236(e)(1)(ii)] | 24.93 |
Dehydrator feed natural gas water content (pounds per MMscf) [98.236(e)(1)(iii)] | 76.41 |
Dehydrator outlet natural gas water content (pounds per MMscf) [98.236(e)(1)(iv)] | 7 |
Glycol dehydrator absorbent circulation pump type [98.236(e)(1)(v)] | Natural gas pneumatic |
Dehydrator absorbent circulation rate (gallons per minute) [98.236(e)(1)(vi)] | 2.06 |
Report type of absorbent used [98.236(e)(1)(vii)] | Triethylene glycol (TEG) |
Report whether stripper gas is used in glycol dehydrator [98.236(e)(1)(viii)] | No |
Report whether a flash tank separator is used in glycol dehydrator [98.236(e)(1)(ix)] | Yes |
Total time the glycol dehydrator is operating (hours) [98.236(e)(1)(x)] | 8760 |
Temperature of the wet natural gas (°F) [98.236(e)(1)(xi)] | 109.01 |
Pressure of the wet natural gas (psig) [98.236(e)(1)(xii)] | 1004.7 |
Concentration of CO2 in wet natural gas (mole fraction) [98.236(e)(1)(xiv)] | 0.00482 |
Concentration of CH4 in wet natural gas (mole fraction) [98.236(e)(1)(xiii)] | 0.771 |
Were any dehydrator emissions vented to a vapor recovery device? [98.236(e)(1)(xv)] | No |
Were any dehydrator emissions vented to a flare or regenerator firebox/fire tubes? [98.236(e)(1)(xvi)] | No |
Were any dehydrator emissions vented to the atmosphere without being routed to a flare or regenerator firebox/fire tubes? [98.236(e)(1)(xvii)] | Yes |
CO2 Emissions from Venting (mt CO2) [98.236(e)(1)(xvii)(A)] | 0.31827 |
CH4 Emissions from Venting (mt CH4) [98.236(e)(1)(xvii)(B)] | 0.73909 |
Unit ID or Name [98.236(e)(1)(i)] | 5-DHY-1-F559 |
County and State [98.236(e)(1)(xviii)] | EDDY, NM |
Glycol dehydrator feed natural gas flow rate determined by engineering estimate based on best available data (MMscfd) [98.236(e)(1)(ii)] | 18.87 |
Dehydrator feed natural gas water content (pounds per MMscf) [98.236(e)(1)(iii)] | 74.22 |
Dehydrator outlet natural gas water content (pounds per MMscf) [98.236(e)(1)(iv)] | 6.57 |
Glycol dehydrator absorbent circulation pump type [98.236(e)(1)(v)] | Natural gas pneumatic |
Dehydrator absorbent circulation rate (gallons per minute) [98.236(e)(1)(vi)] | 2.12 |
Report type of absorbent used [98.236(e)(1)(vii)] | Triethylene glycol (TEG) |
Report whether stripper gas is used in glycol dehydrator [98.236(e)(1)(viii)] | No |
Report whether a flash tank separator is used in glycol dehydrator [98.236(e)(1)(ix)] | Yes |
Total time the glycol dehydrator is operating (hours) [98.236(e)(1)(x)] | 8760 |
Temperature of the wet natural gas (°F) [98.236(e)(1)(xi)] | 108.25 |
Pressure of the wet natural gas (psig) [98.236(e)(1)(xii)] | 1014.7 |
Concentration of CO2 in wet natural gas (mole fraction) [98.236(e)(1)(xiv)] | 0.00106 |
Concentration of CH4 in wet natural gas (mole fraction) [98.236(e)(1)(xiii)] | 0.773 |
Were any dehydrator emissions vented to a vapor recovery device? [98.236(e)(1)(xv)] | No |
Were any dehydrator emissions vented to a flare or regenerator firebox/fire tubes? [98.236(e)(1)(xvi)] | No |
Were any dehydrator emissions vented to the atmosphere without being routed to a flare or regenerator firebox/fire tubes? [98.236(e)(1)(xvii)] | Yes |
CO2 Emissions from Venting (mt CO2) [98.236(e)(1)(xvii)(A)] | 0.07467 |
CH4 Emissions from Venting (mt CH4) [98.236(e)(1)(xvii)(B)] | 0.78277 |
Unit ID or Name [98.236(e)(1)(i)] | 6-DHY-1-F560 |
County and State [98.236(e)(1)(xviii)] | EDDY, NM |
Glycol dehydrator feed natural gas flow rate determined by engineering estimate based on best available data (MMscfd) [98.236(e)(1)(ii)] | 24.87 |
Dehydrator feed natural gas water content (pounds per MMscf) [98.236(e)(1)(iii)] | 88.16 |
Dehydrator outlet natural gas water content (pounds per MMscf) [98.236(e)(1)(iv)] | 7 |
Glycol dehydrator absorbent circulation pump type [98.236(e)(1)(v)] | Natural gas pneumatic |
Dehydrator absorbent circulation rate (gallons per minute) [98.236(e)(1)(vi)] | 2.21 |
Report type of absorbent used [98.236(e)(1)(vii)] | Triethylene glycol (TEG) |
Report whether stripper gas is used in glycol dehydrator [98.236(e)(1)(viii)] | No |
Report whether a flash tank separator is used in glycol dehydrator [98.236(e)(1)(ix)] | Yes |
Total time the glycol dehydrator is operating (hours) [98.236(e)(1)(x)] | 8760 |
Temperature of the wet natural gas (°F) [98.236(e)(1)(xi)] | 113.98 |
Pressure of the wet natural gas (psig) [98.236(e)(1)(xii)] | 991.7 |
Concentration of CO2 in wet natural gas (mole fraction) [98.236(e)(1)(xiv)] | 0.000898 |
Concentration of CH4 in wet natural gas (mole fraction) [98.236(e)(1)(xiii)] | 0.752 |
Were any dehydrator emissions vented to a vapor recovery device? [98.236(e)(1)(xv)] | No |
Were any dehydrator emissions vented to a flare or regenerator firebox/fire tubes? [98.236(e)(1)(xvi)] | No |
Were any dehydrator emissions vented to the atmosphere without being routed to a flare or regenerator firebox/fire tubes? [98.236(e)(1)(xvii)] | Yes |
CO2 Emissions from Venting (mt CO2) [98.236(e)(1)(xvii)(A)] | 0.06157 |
CH4 Emissions from Venting (mt CH4) [98.236(e)(1)(xvii)(B)] | 0.77086 |
Unique Name or ID Number for the Flare Stack [98.236(n)(1)] | WL2 Flare-F176 |
Does the flare stack have a continuous flow monitor on gas to the flare? [98.236(n)(2)] | No |
Does the flare stack have a continuous gas analyzer on gas to the flare? [98.236(n)(3)] | No |
Were CEMS used to measure CO2 emissions for the flare stack? [98.233(n)(8)] [98.236(n)(12)] | No |
Volume of gas sent to flare, Vs (standard cubic feet) [98.236(n)(4)] | 569400 |
Flare combustion efficiency (decimal value) [98.236(n)(6)] | 0.95 |
Mole fraction of CH4 in flare feed gas, XCH4 [98.236(n)(7)] | 0.95492 |
Mole fraction of CO2 in flare feed gas, XCO2 [98.236(n)(8)] | 0.00014 |
Fraction of feed gas sent to un-lit flare, Zu [98.236(n)(5)] | 0 |
CO2 emissions (mt CO2) [98.236(n)(9)] | 29.01564 |
CH4 Emissions (mt CH4) (Eq. W-19) [98.236(n)(10)] | 0.52195 |
N2O Emissions (mt N2O) (Eq. W-40) [98.236(n)(11)] | 0 |
Unique Name or ID Number for the Flare Stack [98.236(n)(1)] | WL1/WLCS Flare-F176 |
Does the flare stack have a continuous flow monitor on gas to the flare? [98.236(n)(2)] | Yes |
Does the flare stack have a continuous gas analyzer on gas to the flare? [98.236(n)(3)] | No |
Were CEMS used to measure CO2 emissions for the flare stack? [98.233(n)(8)] [98.236(n)(12)] | No |
Volume of gas sent to flare, Vs (standard cubic feet) [98.236(n)(4)] | 7091700 |
Flare combustion efficiency (decimal value) [98.236(n)(6)] | 0.98 |
Mole fraction of CH4 in flare feed gas, XCH4 [98.236(n)(7)] | 0.95492 |
Mole fraction of CO2 in flare feed gas, XCO2 [98.236(n)(8)] | 0.00014 |
Fraction of feed gas sent to un-lit flare, Zu [98.236(n)(5)] | 0 |
CO2 emissions (mt CO2) [98.236(n)(9)] | 372.79116 |
CH4 Emissions (mt CH4) (Eq. W-19) [98.236(n)(10)] | 2.60044 |
N2O Emissions (mt N2O) (Eq. W-40) [98.236(n)(11)] | 0.00068 |
Unique Name or ID Number for the Flare Stack [98.236(n)(1)] | ECD-1-F404 |
Does the flare stack have a continuous flow monitor on gas to the flare? [98.236(n)(2)] | No |
Does the flare stack have a continuous gas analyzer on gas to the flare? [98.236(n)(3)] | No |
Were CEMS used to measure CO2 emissions for the flare stack? [98.233(n)(8)] [98.236(n)(12)] | No |
Volume of gas sent to flare, Vs (standard cubic feet) [98.236(n)(4)] | 12336964.42016 |
Flare combustion efficiency (decimal value) [98.236(n)(6)] | 0.98 |
Mole fraction of CH4 in flare feed gas, XCH4 [98.236(n)(7)] | 0.95336 |
Mole fraction of CO2 in flare feed gas, XCO2 [98.236(n)(8)] | 0.00014 |
Fraction of feed gas sent to un-lit flare, Zu [98.236(n)(5)] | 0.00008 |
CO2 emissions (mt CO2) [98.236(n)(9)] | 647.41247 |
CH4 Emissions (mt CH4) (Eq. W-19) [98.236(n)(10)] | 4.51608 |
N2O Emissions (mt N2O) (Eq. W-40) [98.236(n)(11)] | 0.00126 |
Unique Name or ID Number for the Flare Stack [98.236(n)(1)] | FL-5100-F552 |
Does the flare stack have a continuous flow monitor on gas to the flare? [98.236(n)(2)] | No |
Does the flare stack have a continuous gas analyzer on gas to the flare? [98.236(n)(3)] | No |
Were CEMS used to measure CO2 emissions for the flare stack? [98.233(n)(8)] [98.236(n)(12)] | No |
Volume of gas sent to flare, Vs (standard cubic feet) [98.236(n)(4)] | 21056440 |
Flare combustion efficiency (decimal value) [98.236(n)(6)] | 0.98 |
Mole fraction of CH4 in flare feed gas, XCH4 [98.236(n)(7)] | 0.63491 |
Mole fraction of CO2 in flare feed gas, XCO2 [98.236(n)(8)] | 0.00126 |
Fraction of feed gas sent to un-lit flare, Zu [98.236(n)(5)] | 0.0738 |
CO2 emissions (mt CO2) [98.236(n)(9)] | 1681.26495 |
CH4 Emissions (mt CH4) (Eq. W-19) [98.236(n)(10)] | 20.83752 |
N2O Emissions (mt N2O) (Eq. W-40) [98.236(n)(11)] | 0.00323 |
Unique Name or ID Number for the Flare Stack [98.236(n)(1)] | 13-ECD-1-F553 |
Does the flare stack have a continuous flow monitor on gas to the flare? [98.236(n)(2)] | No |
Does the flare stack have a continuous gas analyzer on gas to the flare? [98.236(n)(3)] | No |
Were CEMS used to measure CO2 emissions for the flare stack? [98.233(n)(8)] [98.236(n)(12)] | No |
Volume of gas sent to flare, Vs (standard cubic feet) [98.236(n)(4)] | 440375.8 |
Flare combustion efficiency (decimal value) [98.236(n)(6)] | 0.98 |
Mole fraction of CH4 in flare feed gas, XCH4 [98.236(n)(7)] | 0.42356 |
Mole fraction of CO2 in flare feed gas, XCO2 [98.236(n)(8)] | 0.00106 |
Fraction of feed gas sent to un-lit flare, Zu [98.236(n)(5)] | 0 |
CO2 emissions (mt CO2) [98.236(n)(9)] | 14.87465 |
CH4 Emissions (mt CH4) (Eq. W-19) [98.236(n)(10)] | 0.06189 |
N2O Emissions (mt N2O) (Eq. W-40) [98.236(n)(11)] | 0 |
Unique Name or ID Number for the Flare Stack [98.236(n)(1)] | 14-ECD-1-F554 |
Does the flare stack have a continuous flow monitor on gas to the flare? [98.236(n)(2)] | No |
Does the flare stack have a continuous gas analyzer on gas to the flare? [98.236(n)(3)] | No |
Were CEMS used to measure CO2 emissions for the flare stack? [98.233(n)(8)] [98.236(n)(12)] | No |
Volume of gas sent to flare, Vs (standard cubic feet) [98.236(n)(4)] | 481369.89996 |
Flare combustion efficiency (decimal value) [98.236(n)(6)] | 0.98 |
Mole fraction of CH4 in flare feed gas, XCH4 [98.236(n)(7)] | 0.46669 |
Mole fraction of CO2 in flare feed gas, XCO2 [98.236(n)(8)] | 0.00059 |
Fraction of feed gas sent to un-lit flare, Zu [98.236(n)(5)] | 0 |
CO2 emissions (mt CO2) [98.236(n)(9)] | 17.81556 |
CH4 Emissions (mt CH4) (Eq. W-19) [98.236(n)(10)] | 0.07637 |
N2O Emissions (mt N2O) (Eq. W-40) [98.236(n)(11)] | 0 |
Unique Name or ID Number for the Flare Stack [98.236(n)(1)] | 14-ECD-F555 |
Does the flare stack have a continuous flow monitor on gas to the flare? [98.236(n)(2)] | No |
Does the flare stack have a continuous gas analyzer on gas to the flare? [98.236(n)(3)] | No |
Were CEMS used to measure CO2 emissions for the flare stack? [98.233(n)(8)] [98.236(n)(12)] | No |
Volume of gas sent to flare, Vs (standard cubic feet) [98.236(n)(4)] | 518299.2 |
Flare combustion efficiency (decimal value) [98.236(n)(6)] | 0.98 |
Mole fraction of CH4 in flare feed gas, XCH4 [98.236(n)(7)] | 0.40966 |
Mole fraction of CO2 in flare feed gas, XCO2 [98.236(n)(8)] | 0.00049 |
Fraction of feed gas sent to un-lit flare, Zu [98.236(n)(5)] | 0 |
CO2 emissions (mt CO2) [98.236(n)(9)] | 15.11583 |
CH4 Emissions (mt CH4) (Eq. W-19) [98.236(n)(10)] | 0.06383 |
N2O Emissions (mt N2O) (Eq. W-40) [98.236(n)(11)] | 0 |
Unique Name or ID Number for the Flare Stack [98.236(n)(1)] | 14-ECD-F556 |
Does the flare stack have a continuous flow monitor on gas to the flare? [98.236(n)(2)] | No |
Does the flare stack have a continuous gas analyzer on gas to the flare? [98.236(n)(3)] | No |
Were CEMS used to measure CO2 emissions for the flare stack? [98.233(n)(8)] [98.236(n)(12)] | No |
Volume of gas sent to flare, Vs (standard cubic feet) [98.236(n)(4)] | 608936.79996 |
Flare combustion efficiency (decimal value) [98.236(n)(6)] | 0.98 |
Mole fraction of CH4 in flare feed gas, XCH4 [98.236(n)(7)] | 0.33913 |
Mole fraction of CO2 in flare feed gas, XCO2 [98.236(n)(8)] | 0.00045 |
Fraction of feed gas sent to un-lit flare, Zu [98.236(n)(5)] | 0 |
CO2 emissions (mt CO2) [98.236(n)(9)] | 15.57684 |
CH4 Emissions (mt CH4) (Eq. W-19) [98.236(n)(10)] | 0.06305 |
N2O Emissions (mt N2O) (Eq. W-40) [98.236(n)(11)] | 0 |
Unique Name or ID Number for the Flare Stack [98.236(n)(1)] | 13-ECD-1-F558 |
Does the flare stack have a continuous flow monitor on gas to the flare? [98.236(n)(2)] | No |
Does the flare stack have a continuous gas analyzer on gas to the flare? [98.236(n)(3)] | No |
Were CEMS used to measure CO2 emissions for the flare stack? [98.233(n)(8)] [98.236(n)(12)] | No |
Volume of gas sent to flare, Vs (standard cubic feet) [98.236(n)(4)] | 427956.89996 |
Flare combustion efficiency (decimal value) [98.236(n)(6)] | 0.98 |
Mole fraction of CH4 in flare feed gas, XCH4 [98.236(n)(7)] | 0.50111 |
Mole fraction of CO2 in flare feed gas, XCO2 [98.236(n)(8)] | 0.00072 |
Fraction of feed gas sent to un-lit flare, Zu [98.236(n)(5)] | 0 |
CO2 emissions (mt CO2) [98.236(n)(9)] | 17.95935 |
CH4 Emissions (mt CH4) (Eq. W-19) [98.236(n)(10)] | 0.07174 |
N2O Emissions (mt N2O) (Eq. W-40) [98.236(n)(11)] | 0 |
Unique Name or ID Number for the Flare Stack [98.236(n)(1)] | 12-ECD-F559 |
Does the flare stack have a continuous flow monitor on gas to the flare? [98.236(n)(2)] | No |
Does the flare stack have a continuous gas analyzer on gas to the flare? [98.236(n)(3)] | No |
Were CEMS used to measure CO2 emissions for the flare stack? [98.233(n)(8)] [98.236(n)(12)] | No |
Volume of gas sent to flare, Vs (standard cubic feet) [98.236(n)(4)] | 426086.59996 |
Flare combustion efficiency (decimal value) [98.236(n)(6)] | 0.98 |
Mole fraction of CH4 in flare feed gas, XCH4 [98.236(n)(7)] | 0.43865 |
Mole fraction of CO2 in flare feed gas, XCO2 [98.236(n)(8)] | 0.00055 |
Fraction of feed gas sent to un-lit flare, Zu [98.236(n)(5)] | 0 |
CO2 emissions (mt CO2) [98.236(n)(9)] | 16.04189 |
CH4 Emissions (mt CH4) (Eq. W-19) [98.236(n)(10)] | 0.06342 |
N2O Emissions (mt N2O) (Eq. W-40) [98.236(n)(11)] | 0 |
Unique Name or ID Number for the Flare Stack [98.236(n)(1)] | 12-ECD-F560 |
Does the flare stack have a continuous flow monitor on gas to the flare? [98.236(n)(2)] | No |
Does the flare stack have a continuous gas analyzer on gas to the flare? [98.236(n)(3)] | No |
Were CEMS used to measure CO2 emissions for the flare stack? [98.233(n)(8)] [98.236(n)(12)] | No |
Volume of gas sent to flare, Vs (standard cubic feet) [98.236(n)(4)] | 537442.00004 |
Flare combustion efficiency (decimal value) [98.236(n)(6)] | 0.98 |
Mole fraction of CH4 in flare feed gas, XCH4 [98.236(n)(7)] | 0.34619 |
Mole fraction of CO2 in flare feed gas, XCO2 [98.236(n)(8)] | 0.00041 |
Fraction of feed gas sent to un-lit flare, Zu [98.236(n)(5)] | 0 |
CO2 emissions (mt CO2) [98.236(n)(9)] | 16.63992 |
CH4 Emissions (mt CH4) (Eq. W-19) [98.236(n)(10)] | 0.06638 |
N2O Emissions (mt N2O) (Eq. W-40) [98.236(n)(11)] | 0 |
Emission Source Type (Eq. W-32A) [98.232(c)(21)] [98.233(r)] | Gas Service - Valves |
Geographic Location (according to Table W-1D) [98.236(r)(1)(i)] | Western U.S. |
Total number of emission source type, Counte (for gathering pipelines, this value is the number of miles of pipeline per material type) [98.236(r)(1)(ii)] | 5043 |
Average estimated time that the emission source type was operational in the calendar year, Te (hours) [98.236(r)(1)(iii)] | 8760 |
CO2 Emissions (mt CO2) [98.236(r)(1)(iv)] | 0.58857 |
CH4 Emissions (mt CH4) [98.236(r)(1)(v)] | 79.59084 |
Emission Source Type (Eq. W-32A) [98.232(c)(21)] [98.233(r)] | Gas Service - Connectors |
Geographic Location (according to Table W-1D) [98.236(r)(1)(i)] | Western U.S. |
Total number of emission source type, Counte (for gathering pipelines, this value is the number of miles of pipeline per material type) [98.236(r)(1)(ii)] | 18182 |
Average estimated time that the emission source type was operational in the calendar year, Te (hours) [98.236(r)(1)(iii)] | 8760 |
CO2 Emissions (mt CO2) [98.236(r)(1)(iv)] | 0.28531 |
CH4 Emissions (mt CH4) [98.236(r)(1)(v)] | 40.21649 |
Emission Source Type (Eq. W-32A) [98.232(c)(21)] [98.233(r)] | Gas Service - Open ended lines |
Geographic Location (according to Table W-1D) [98.236(r)(1)(i)] | Western U.S. |
Total number of emission source type, Counte (for gathering pipelines, this value is the number of miles of pipeline per material type) [98.236(r)(1)(ii)] | 380 |
Average estimated time that the emission source type was operational in the calendar year, Te (hours) [98.236(r)(1)(iii)] | 8760 |
CO2 Emissions (mt CO2) [98.236(r)(1)(iv)] | 0.01342 |
CH4 Emissions (mt CH4) [98.236(r)(1)(v)] | 1.5548 |
Emission Source Type (Eq. W-32A) [98.232(c)(21)] [98.233(r)] | Gas Service - Pressure relief valves |
Geographic Location (according to Table W-1D) [98.236(r)(1)(i)] | Western U.S. |
Total number of emission source type, Counte (for gathering pipelines, this value is the number of miles of pipeline per material type) [98.236(r)(1)(ii)] | 357 |
Average estimated time that the emission source type was operational in the calendar year, Te (hours) [98.236(r)(1)(iii)] | 8760 |
CO2 Emissions (mt CO2) [98.236(r)(1)(iv)] | 0.06401 |
CH4 Emissions (mt CH4) [98.236(r)(1)(v)] | 8.96756 |
Emission Source Type (Eq. W-32A) [98.232(c)(21)] [98.233(r)] | Gathering pipelines - Protected steel gathering pipeline |
Geographic Location (according to Table W-1D) [98.236(r)(1)(i)] | Western U.S. |
Total number of emission source type, Counte (for gathering pipelines, this value is the number of miles of pipeline per material type) [98.236(r)(1)(ii)] | 456.81 |
Average estimated time that the emission source type was operational in the calendar year, Te (hours) [98.236(r)(1)(iii)] | 8760 |
CO2 Emissions (mt CO2) [98.236(r)(1)(iv)] | 0.09772 |
CH4 Emissions (mt CH4) [98.236(r)(1)(v)] | 28.15532 |
Emission Source Type (Eq. W-32A) [98.232(c)(21)] [98.233(r)] | Gathering pipelines - Unprotected steel gathering pipeline |
Geographic Location (according to Table W-1D) [98.236(r)(1)(i)] | Western U.S. |
Total number of emission source type, Counte (for gathering pipelines, this value is the number of miles of pipeline per material type) [98.236(r)(1)(ii)] | 0 |
Average estimated time that the emission source type was operational in the calendar year, Te (hours) [98.236(r)(1)(iii)] | 0 |
CO2 Emissions (mt CO2) [98.236(r)(1)(iv)] | 0 |
CH4 Emissions (mt CH4) [98.236(r)(1)(v)] | 0 |
Emission Source Type (Eq. W-32A) [98.232(c)(21)] [98.233(r)] | Gathering pipelines - Plastic/composite gathering pipeline |
Geographic Location (according to Table W-1D) [98.236(r)(1)(i)] | Western U.S. |
Total number of emission source type, Counte (for gathering pipelines, this value is the number of miles of pipeline per material type) [98.236(r)(1)(ii)] | 4.74 |
Average estimated time that the emission source type was operational in the calendar year, Te (hours) [98.236(r)(1)(iii)] | 8760 |
CO2 Emissions (mt CO2) [98.236(r)(1)(iv)] | 0.00842 |
CH4 Emissions (mt CH4) [98.236(r)(1)(v)] | 1.52106 |
Emission Source Type (Eq. W-32A) [98.232(c)(21)] [98.233(r)] | Gathering pipelines - Cast iron gathering pipeline |
Geographic Location (according to Table W-1D) [98.236(r)(1)(i)] | Western U.S. |
Total number of emission source type, Counte (for gathering pipelines, this value is the number of miles of pipeline per material type) [98.236(r)(1)(ii)] | 0 |
Average estimated time that the emission source type was operational in the calendar year, Te (hours) [98.236(r)(1)(iii)] | 0 |
CO2 Emissions (mt CO2) [98.236(r)(1)(iv)] | 0 |
CH4 Emissions (mt CH4) [98.236(r)(1)(v)] | 0 |