Facility Name:KERN RIVER GAS TRANSMISSION COMPANY: SALT LAKE COMPRESSOR STATION
Facility Identifier:
Facility Reporting Year:2020
Facility Location:
Address: 5051 west 150 south
City: SALT LAKE CITY
State: UT
Postal Code: 84104

Facility Site Details:
CO2 equivalent emissions from facility subparts C-II, SS, and TT (metric tons):54,513.6
CO2 equivalent emissions from supplier subparts LL-QQ (metric tons):
Biogenic CO2 emissions from facility subparts C-II, SS, and TT (metric tons):0
Cogeneration Unit Emissions Indicator:N
GHG Report Start Date:2020-01-01
GHG Report End Date:2020-12-31
Description of Changes to Calculation Methodology:
Plant Code Indicator:N
Primary NAICS Code:486210
Second Primary NAICS Code:

Parent Company Details:
Parent Company Name:BERKSHIRE HATHAWAY INC
Address:3555 Farnam Street, Omaha,  NE 68131
Percent Ownership Interest:100

Subpart C: General Stationary Fuel Combustion

Gas Information Details

Gas NameCarbon Dioxide
Gas Quantity52,695.6 (Metric Tons)
Own Result?

Gas NameBiogenic Carbon dioxide
Gas Quantity0 (Metric Tons)
Own Result?

Gas NameMethane
Gas Quantity0.99 (Metric Tons)
Own Result?

Gas NameNitrous Oxide
Gas Quantity0.099 (Metric Tons)
Own Result?

Unit Details:
Unit Name : Unit 1
Unit Type : SCCT (CT (Turbine, simple cycle combustion))
Unit Description :
Individual Unit Details:
Use Ivt Indicator: Y
Maximum Rated Heat Input Capacity: 106 (mmBtu/hr)

Emission Details:
Annual CO2 mass emissions from sorbent: 0 (Metric Tons)
Annual Biogenic CO2 Emissions: 0 (metric tons)

Tier Fuel Details:
Fuel : Natural Gas (Weighted U.S. Average)
Tier Name : Tier 2 (Equation C-2a)
Tier Methodology Start Date : 2020-01-01
Tier Methodology End Date : 2020-12-31
Frequency of HHV determinations : Monthly

Tier 2 Monthly HHV Details :
JanuaryFebruaryMarchAprilMayJuneJulyAugustSeptemberOctoberNovemberDecember
N N N N N N N N N N N N

Fuel Emission Details :
Total CO2 emissionsTotal CH4 emissionsTotal N2O emissionsTotal CH4 emissions CO2eTotal N2O emissions CO2e
26735.7 (Metric Tons) 0.50 (Metric Tons) 0.050 (Metric Tons) 12.6 (Metric Tons) 15 (Metric Tons)


Unit Name : Unit 2
Unit Type : SCCT (CT (Turbine, simple cycle combustion))
Unit Description :
Individual Unit Details:
Use Ivt Indicator: Y
Maximum Rated Heat Input Capacity: 106 (mmBtu/hr)

Emission Details:
Annual CO2 mass emissions from sorbent: 0 (Metric Tons)
Annual Biogenic CO2 Emissions: 0 (metric tons)

Tier Fuel Details:
Fuel : Natural Gas (Weighted U.S. Average)
Tier Name : Tier 2 (Equation C-2a)
Tier Methodology Start Date : 2020-01-01
Tier Methodology End Date : 2020-12-31
Frequency of HHV determinations : Monthly

Tier 2 Monthly HHV Details :
JanuaryFebruaryMarchAprilMayJuneJulyAugustSeptemberOctoberNovemberDecember
N N N N N N N N N N N N

Fuel Emission Details :
Total CO2 emissionsTotal CH4 emissionsTotal N2O emissionsTotal CH4 emissions CO2eTotal N2O emissions CO2e
25837.7 (Metric Tons) 0.49 (Metric Tons) 0.049 (Metric Tons) 12.2 (Metric Tons) 14.5 (Metric Tons)


Unit Name : Boiler
Unit Type : OB (Boiler, other)
Unit Description :
Individual Unit Details:
Use Ivt Indicator: Y
Maximum Rated Heat Input Capacity: 3.85 (mmBtu/hr)

Emission Details:
Annual CO2 mass emissions from sorbent: 0 (Metric Tons)
Annual Biogenic CO2 Emissions: 0 (metric tons)

Tier Fuel Details:
Fuel : Natural Gas (Weighted U.S. Average)
Tier Name : Tier 2 (Equation C-2a)
Tier Methodology Start Date : 2020-01-01
Tier Methodology End Date : 2020-12-31
Frequency of HHV determinations : Monthly

Tier 2 Monthly HHV Details :
JanuaryFebruaryMarchAprilMayJuneJulyAugustSeptemberOctoberNovemberDecember
N N N N N N N N N N N N

Fuel Emission Details :
Total CO2 emissionsTotal CH4 emissionsTotal N2O emissionsTotal CH4 emissions CO2eTotal N2O emissions CO2e
122.2 (Metric Tons) 0.00 (Metric Tons) 0.000 (Metric Tons) 0.1 (Metric Tons) 0.1 (Metric Tons)



Subpart W: Petroleum and Natural Gas Systems

Gas Information Details

Gas NameCarbon Dioxide
Gas Quantity203.5 (Metric Tons)
Own Result?

Gas NameMethane
Gas Quantity62.41 (Metric Tons)
Own Result?

Gas NameNitrous Oxide
Gas Quantity0 (Metric Tons)
Own Result?


SubpartWSummaryDetails:
Industry Segment Number4
Industry Segment NameOnshore natural gas transmission compression [98.230(a)(4)]
Total Reported CO2 Emissions (mt CO2)203.5
Total CO2e Emissions (mt CO2e)1763.8
Total Reported CH4 Emissions (mt CH4)62.41
Total Reported N2O Emissions (mt N2O)0.000


SubpartWSourceReportingFormRowDetails:
Source Reporting FormOnshore Production [98.236(aa)(1)]
Required for Selected Industry SegmentNo
Source Reporting FormFacility Overview [98.236(aa)(2-11)]
Required for Selected Industry SegmentYes
Source Reporting FormNatural Gas Pneumatic Devices [98.236(b)]
Required for Selected Industry SegmentYes
Total Reported CO2 Emissions (mt CO2)0.2
Total Reported CH4 Emissions (mt CH4)7.91
Source Reporting FormNatural Gas Driven Pneumatic Pumps [98.236(c)]
Required for Selected Industry SegmentNo
Total Reported CO2 Emissions (mt CO2)0.0
Total Reported CH4 Emissions (mt CH4)0.00
Source Reporting FormAcid Gas Removal Units [98.236(d)]
Required for Selected Industry SegmentNo
Total Reported CO2 Emissions (mt CO2)0.0
Source Reporting FormDehydrators [98.236(e)]
Required for Selected Industry SegmentNo
Total Reported CO2 Emissions (mt CO2)0.0
Total Reported CH4 Emissions (mt CH4)0.00
Total Reported N2O Emissions (mt N2O)0.000
Source Reporting FormWell Venting for Liquids Unloading [98.236(f)]
Required for Selected Industry SegmentNo
Total Reported CO2 Emissions (mt CO2)0.0
Total Reported CH4 Emissions (mt CH4)0.00
Source Reporting FormCompletions and Workovers with Hydraulic Fracturing [98.236(g)]
Required for Selected Industry SegmentNo
Total Reported CO2 Emissions (mt CO2)0.0
Total Reported CH4 Emissions (mt CH4)0.00
Total Reported N2O Emissions (mt N2O)0.000
Source Reporting FormCompletions and Workovers without Hydraulic Fracturing [98.236(h)]
Required for Selected Industry SegmentNo
Total Reported CO2 Emissions (mt CO2)0.0
Total Reported CH4 Emissions (mt CH4)0.00
Total Reported N2O Emissions (mt N2O)0.000
Source Reporting FormBlowdown Vent Stacks [98.236(i)]
Required for Selected Industry SegmentYes
Total Reported CO2 Emissions (mt CO2)1.4
Total Reported CH4 Emissions (mt CH4)49.48
Source Reporting FormAtmospheric Storage Tanks [98.236(j)]
Required for Selected Industry SegmentNo
Total Reported CO2 Emissions (mt CO2)0.0
Total Reported CH4 Emissions (mt CH4)0.00
Total Reported N2O Emissions (mt N2O)0.000
Source Reporting FormTransmission Storage Tanks [98.236(k)]
Required for Selected Industry SegmentYes
Total Reported CO2 Emissions (mt CO2)0.0
Total Reported CH4 Emissions (mt CH4)0.00
Total Reported N2O Emissions (mt N2O)0.000
Source Reporting FormWell Testing [98.236(l)]
Required for Selected Industry SegmentNo
Total Reported CO2 Emissions (mt CO2)0.0
Total Reported CH4 Emissions (mt CH4)0.00
Total Reported N2O Emissions (mt N2O)0.000
Source Reporting FormAssociated Gas Venting and Flaring [98.236(m)]
Required for Selected Industry SegmentNo
Total Reported CO2 Emissions (mt CO2)0.0
Total Reported CH4 Emissions (mt CH4)0.00
Total Reported N2O Emissions (mt N2O)0.000
Source Reporting FormFlare Stacks [98.236(n)]
Required for Selected Industry SegmentYes
Total Reported CO2 Emissions (mt CO2)201.7
Total Reported CH4 Emissions (mt CH4)1.35
Total Reported N2O Emissions (mt N2O)0.000
Source Reporting FormCentrifugal Compressors [98.236(o)]
Required for Selected Industry SegmentYes
Total Reported CO2 Emissions (mt CO2)0.0
Total Reported CH4 Emissions (mt CH4)0.02
Source Reporting FormReciprocating Compressors [98.236(p)]
Required for Selected Industry SegmentYes
Total Reported CO2 Emissions (mt CO2)0.0
Total Reported CH4 Emissions (mt CH4)0.00
Source Reporting FormEquipment Leaks Surveys and Population Counts [98.236(q,r)]
Required for Selected Industry SegmentYes
Total Reported CO2 Emissions (mt CO2)0.1
Total Reported CH4 Emissions (mt CH4)3.65
Source Reporting FormOffshore Petroleum and Natural Gas Production [98.236(s)]
Required for Selected Industry SegmentNo
Total Reported CO2 Emissions (mt CO2)0.0
Total Reported CH4 Emissions (mt CH4)0.00
Total Reported N2O Emissions (mt N2O)0.000
Source Reporting FormEnhanced Oil Recovery Injection Pumps [98.236(w)]
Required for Selected Industry SegmentNo
Total Reported CO2 Emissions (mt CO2)0.0
Source Reporting FormEnhanced Oil Recovery Hydrocarbon Liquids [98.236(x)]
Required for Selected Industry SegmentNo
Total Reported CO2 Emissions (mt CO2)0.0
Source Reporting FormCombustion Equipment at Onshore Petroleum and Natural Gas Production Facilities, Onshore Petroleum and Natural Gas Gathering and Boosting Facilities, and Natural gas Distribution Facilities [98.236(z)]
Required for Selected Industry SegmentNo
Total Reported CO2 Emissions (mt CO2)0.0
Total Reported CH4 Emissions (mt CH4)0.00
Total Reported N2O Emissions (mt N2O)0.000


FacilityOverviewDetails:


FacilityOverviewNaturalGasTransmissionRowDetails:
Number of compressors [98.236(aa)(4)(ii)]2
Total compressor power rating of all compressors combined (hp) [98.236(aa)(4)(iii)]30000


PneumaticDeviceVentingDetails:
mt CO20.2
mt CH47.91
Did the Facility have any continuous high-bleed pneumatic devices subject to reporting under 98.232 [98.236(b)]?No
Did the Facility have any intermittent bleed pneumatic devices subject to reporting under 98.232 [98.236(b)]?Yes
Did the Facility have any continuous low-bleed pneumatic devices subject to reporting under 98.232 [98.236(b)]?No
Were missing data procedures used for any parameters to calculate GHG emissions? [98.235]No


PneumaticDeviceTypesRowDetails:
Type of Pneumatic DeviceHigh-bleed Pneumatic Devices
Type of Pneumatic DeviceIntermittent Bleed Pneumatic Devices
Total Number, Countt [98.236(b)(1)(i)]21
Total CO2 Emissions (mt CO2) [98.236(b)(3)]0.228016
Total CH4 Emissions (mt CH4) [98.236(b)(4)]7.9068649
Estimated average number of hours in the calendar year that the pneumatic devices were operating, Tt (hours) [98.236(b)(2)]8784
Type of Pneumatic DeviceLow-Bleed Pneumatic Devices


BlowdownVentStacksDetails:
mt CO21.4
mt CH449.48
Did the facility have any blowdown vent stacks subject to reporting under 98.232 [98.236(i)]?Yes
Were missing data procedures used for any parameters to calculate GHG emissions? [98.235]No
How were emissions determined? [98.236(i)]Calculated by equipment or event type


BlowdownEquipmentOrEventEmissionsRowDetails:
Equipment or event type [98.236(i)(1)] [98.236(i)(2)]Compressors
Total number of blowdowns for equipment or event type, N [98.236(i)(1)(i)]33
Annual total CO2 emissions for each equipment or event type (mt CO2) [98.236(i)(1)(ii)]1.4269504
Annual total CH4 emissions for each equipment or event type (mt CH4) [98.236(i)(1)(iii)]49.4820839


TransmissionTanksDetails:
mt CO20.0
mt CH40.00
mt N2O0.000
Did the facility have any transmission tanks subject to reporting under 98.232 [98.236(k)]?Yes
Were missing data procedures used for any parameters to calculate GHG emissions? [98.235]No


TransmissionStorageTanksRowDetails:
Unique Name or ID number for the transmission storage tank vent stack [98.236(k)(1)(i)]SL-T-100
Method used to determine if dump valve leakage occurred [98.236(k)(1)(ii)]Optical gas imaging
Did dump valve leakage occur? [98.236(k)(1)(iii)]No
Was there a flare attached to the transmission storage tank vent? [98.236(k)(1)(iv)]No


FlareStacksDetails:
mt CO2201.7
mt CH41.35
mt N2O0.000
Did the facility have flare stacks subject to reporting under 98.232 [98.236(n)]?Yes
Were missing data procedures used for any parameters to calculate GHG emissions? [98.235]No


UniqueFlareStacksRowDetails:
Unique Name or ID Number for the Flare Stack [98.236(n)(1)]SL-F-1
Does the flare stack have a continuous flow monitor on gas to the flare? [98.236(n)(2)]No
Does the flare stack have a continuous gas analyzer on gas to the flare? [98.236(n)(3)]No
Were CEMS used to measure CO2 emissions for the flare stack? [98.233(n)(8)] [98.236(n)(12)]No
Volume of gas sent to flare, Vs (standard cubic feet) [98.236(n)(4)]3738788.579
Flare combustion efficiency (decimal value) [98.236(n)(6)]0.98
Mole fraction of CH4 in flare feed gas, XCH4 [98.236(n)(7)]0.9434
Mole fraction of CO2 in flare feed gas, XCO2 [98.236(n)(8)]0.0084
Fraction of feed gas sent to un-lit flare, Zu [98.236(n)(5)]0
CO2 emissions (mt CO2) [98.236(n)(9)]201.7193442
CH4 Emissions (mt CH4) (Eq. W-19) [98.236(n)(10)]1.3544376
N2O Emissions (mt N2O) (Eq. W-40) [98.236(n)(11)]0.0003836


CentrifugalCompressorsDetails:
mt CO20.0
mt CH40.02
Did the facility have any centrifugal compressors subject to reporting under 98.232 [98.236(o)]?Yes
Were missing data procedures used for any parameters to calculate GHG emissions? [98.235]No


CentrifugalCompressorsActivityDataRowDetails:
Compressor ID or Unique Name [98.236(o)(1)(i)]SL-C-101
Total time in operating-mode (hours) [98.236(o)(1)(ii)]5152
Total time in not-operating-depressurized-mode (hours) [98.236(o)(1)(iii)]3632
Compressor measured in operating-mode? [98.236(o)(1)(iv)]No
Compressor measured in not-operating-depressurized-mode? [98.236(o)(1)(v)]Yes
Compressor had blind flanges installed? [98.236(o)(1)(x)]No
Seal Type (wet or dry) [98.236(o)(1)(xi)]Dry
Power output of compressor driver (hp) [98.236(o)(1)(xiii)]15000
Compressor had scheduled depressurized shutdown during reporting year? [98.236(o)(1)(xiv)]Yes
Compressor ID or Unique Name [98.236(o)(1)(i)]SL-C-102
Total time in operating-mode (hours) [98.236(o)(1)(ii)]5040
Total time in not-operating-depressurized-mode (hours) [98.236(o)(1)(iii)]3744
Compressor measured in operating-mode? [98.236(o)(1)(iv)]No
Compressor measured in not-operating-depressurized-mode? [98.236(o)(1)(v)]Yes
Compressor had blind flanges installed? [98.236(o)(1)(x)]No
Seal Type (wet or dry) [98.236(o)(1)(xi)]Dry
Power output of compressor driver (hp) [98.236(o)(1)(xiii)]15000
Compressor had scheduled depressurized shutdown during reporting year? [98.236(o)(1)(xiv)]Yes


CentrifugalCompressorsCompressorSourceRowDetails:
Unique Compressor Name or ID [98.236(o)(2)(i)(A)]SL-C-101
Centrifugal compressor source [98.236(o)(2)(i)(B)]Blowdown valve
Unique Name or ID for leak or vent [98.236(o)(2)(i)(C)]SL-C-101-bdv
Unique Compressor Name or ID [98.236(o)(2)(i)(A)]SL-C-101
Centrifugal compressor source [98.236(o)(2)(i)(B)]Isolation valve
Unique Name or ID for leak or vent [98.236(o)(2)(i)(C)]SL-C-101-isv
Unique Compressor Name or ID [98.236(o)(2)(i)(A)]SL-C-101
Centrifugal compressor source [98.236(o)(2)(i)(B)]Wet seal
Unique Compressor Name or ID [98.236(o)(2)(i)(A)]SL-C-102
Centrifugal compressor source [98.236(o)(2)(i)(B)]Blowdown valve
Unique Name or ID for leak or vent [98.236(o)(2)(i)(C)]SL-C-102-bdv
Unique Compressor Name or ID [98.236(o)(2)(i)(A)]SL-C-102
Centrifugal compressor source [98.236(o)(2)(i)(B)]Isolation valve
Unique Name or ID for leak or vent [98.236(o)(2)(i)(C)]SL-C-102-isv
Unique Compressor Name or ID [98.236(o)(2)(i)(A)]SL-C-102
Centrifugal compressor source [98.236(o)(2)(i)(B)]Wet seal


CentrifugalCompressorsLeakOrVentSampleDataRowDetails:
Unique Name or ID for leak or vent (Specify) [98.236(o)(3)(i)(A)]SL-C-101-isv
Measurement date (mm/dd/yyyy) [98.236(o)(3)(i)(B)]2020-07-09
Measurement method [98.236(o)(3)(i)(C)]Screening/Acoustic leak detection
Measured flow rate, MTs,m, MTs,g,avg (standard cubic feet/hour) [98.236(o)(3)(i)(D)]0
Is the measurement location prior to or after commingling with non-compressor emission sources? [98.236(o)(3)(i)(F)]Not manifolded
Compressors in “Not-operating mode”SL-C-101
Unique Name or ID for leak or vent (Specify) [98.236(o)(3)(i)(A)]SL-C-102-isv
Measurement date (mm/dd/yyyy) [98.236(o)(3)(i)(B)]2020-07-09
Measurement method [98.236(o)(3)(i)(C)]Screening/Acoustic leak detection
Measured flow rate, MTs,m, MTs,g,avg (standard cubic feet/hour) [98.236(o)(3)(i)(D)]0
Is the measurement location prior to or after commingling with non-compressor emission sources? [98.236(o)(3)(i)(F)]Not manifolded
Compressors in “Not-operating mode”SL-C-102


CentrifugalCompressorsEmissionFactorsSampleDataRowDetails:
Compressor Mode [98.236(o)(3)(ii)(A)]Operating
Compressor Source [98.236(o)(3)(ii)(A)]Wet seal
Compressor mode-source combination reporter emission factor, EFs,m (standard cubic feet per hour) [98.236(o)(3)(ii)(B)]0
Total number of compressors measured in the compressor mode-source combination in current reporting year and preceding two reporting years [98.236(o)(3)(ii)(C)]0
Is the reporter emission factor facility-specific or based on all of the reporter's applicable facilities? [98.236(o)(3)(ii)(D)]All applicable facilities
Compressor Mode [98.236(o)(3)(ii)(A)]Operating
Compressor Source [98.236(o)(3)(ii)(A)]Blowdown valve
Compressor mode-source combination reporter emission factor, EFs,m (standard cubic feet per hour) [98.236(o)(3)(ii)(B)]0.0896552
Total number of compressors measured in the compressor mode-source combination in current reporting year and preceding two reporting years [98.236(o)(3)(ii)(C)]29
Is the reporter emission factor facility-specific or based on all of the reporter's applicable facilities? [98.236(o)(3)(ii)(D)]All applicable facilities
Compressor Mode [98.236(o)(3)(ii)(A)]Not-operating
Compressor Source [98.236(o)(3)(ii)(A)]Isolation valve
Compressor mode-source combination reporter emission factor, EFs,m (standard cubic feet per hour) [98.236(o)(3)(ii)(B)]0.323913
Total number of compressors measured in the compressor mode-source combination in current reporting year and preceding two reporting years [98.236(o)(3)(ii)(C)]46
Is the reporter emission factor facility-specific or based on all of the reporter's applicable facilities? [98.236(o)(3)(ii)(D)]All applicable facilities


CentrifugalCompressorsLeakOrVentDataRowDetails:
Unique Name or ID for leak or vent [98.236(o)(2)(i)(C)]SL-C-101-bdv
Leak or vent for a single compressor source or a manifolded group? [98.236(o)(2)(ii)(A)] [98.236(o)(1)(vi)]Single
Where are leak or vent emissions released? [98.236(o)(2)(ii)(A)] [98.236(o)(1)(vii) through (ix)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(o)(2)(ii)(B)]No
Were continuous measurements conducted on the leak or vent? [98.236(o)(2)(ii)(C)]No
CO2 emissions vented to atmosphere (mt CO2) [98.236(o)(2)(ii)(D)(1)]0.000243
CH4 emissions vented to atmosphere (mt CH4) [98.236(o)(2)(ii)(D)(2)]0.0084251
Unique Name or ID for leak or vent [98.236(o)(2)(i)(C)]SL-C-101-isv
Leak or vent for a single compressor source or a manifolded group? [98.236(o)(2)(ii)(A)] [98.236(o)(1)(vi)]Single
Where are leak or vent emissions released? [98.236(o)(2)(ii)(A)] [98.236(o)(1)(vii) through (ix)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(o)(2)(ii)(B)]Yes
Were continuous measurements conducted on the leak or vent? [98.236(o)(2)(ii)(C)]No
CO2 emissions vented to atmosphere (mt CO2) [98.236(o)(2)(ii)(D)(1)]0
CH4 emissions vented to atmosphere (mt CH4) [98.236(o)(2)(ii)(D)(2)]0
Unique Name or ID for leak or vent [98.236(o)(2)(i)(C)]SL-C-102-bdv
Leak or vent for a single compressor source or a manifolded group? [98.236(o)(2)(ii)(A)] [98.236(o)(1)(vi)]Single
Where are leak or vent emissions released? [98.236(o)(2)(ii)(A)] [98.236(o)(1)(vii) through (ix)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(o)(2)(ii)(B)]No
Were continuous measurements conducted on the leak or vent? [98.236(o)(2)(ii)(C)]No
CO2 emissions vented to atmosphere (mt CO2) [98.236(o)(2)(ii)(D)(1)]0.0002377
CH4 emissions vented to atmosphere (mt CH4) [98.236(o)(2)(ii)(D)(2)]0.008242
Unique Name or ID for leak or vent [98.236(o)(2)(i)(C)]SL-C-102-isv
Leak or vent for a single compressor source or a manifolded group? [98.236(o)(2)(ii)(A)] [98.236(o)(1)(vi)]Single
Where are leak or vent emissions released? [98.236(o)(2)(ii)(A)] [98.236(o)(1)(vii) through (ix)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(o)(2)(ii)(B)]Yes
Were continuous measurements conducted on the leak or vent? [98.236(o)(2)(ii)(C)]No
CO2 emissions vented to atmosphere (mt CO2) [98.236(o)(2)(ii)(D)(1)]0
CH4 emissions vented to atmosphere (mt CH4) [98.236(o)(2)(ii)(D)(2)]0


ReciprocatingCompressorsDetails:
mt CO20.0
mt CH40.00
Did the facility have any reciprocating compressors subject to reporting under 98.232 [98.236(p)]?No


OtherEmissionsFromEquipmentLeaksDetails:
mt CO20.1
mt CH43.65
Did this facility use leak surveys to calculate emissions from equipment leaks in accordance with 98.232 [per 98.236(q)]?Yes
Did the facility elect to comply with 98.236(q) according to 98.233(q)(1)(iv) for any components at the facility [per 98.236(q)(1)(iv)]?No
Were missing data procedures used for any parameters to calculate GHG emissions? [98.235]No
Number of complete equipment leak surveys performed during the calendar year [98.236(q)(1)(i)]1
Optical gas imaging instrument as specified in §60.18 [98.234(a)(1)]Yes
Method 21 [98.234(a)(2)]No
Infrared laser beam illuminated instrument [98.234(a)(3)]No
Acoustic leak detection device [98.234(a)(5)]No
Optical gas imaging instrument as specified in §60.5397a [98.234(a)(6)]No
Method 21 as specified in §60.5397a [98.234(a)(7)]No


GasTransmissionCompressionEmissionFactorsRowDetails:
Component Type [98.236(q)(2)(i)]Compressor Components, Gas Service - Valve
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)]0
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)]0
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)]0
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)]0
Component Type [98.236(q)(2)(i)]Compressor Components, Gas Service - Connector
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)]0
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)]0
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)]0
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)]0
Component Type [98.236(q)(2)(i)]Compressor Components, Gas Service - Open-ended Line
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)]0
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)]0
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)]0
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)]0
Component Type [98.236(q)(2)(i)]Compressor Components, Gas Service - Pressure Relief Valve
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)]0
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)]0
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)]0
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)]0
Component Type [98.236(q)(2)(i)]Compressor Components, Gas Service - Meter or Instrument
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)]0
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)]0
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)]0
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)]0
Component Type [98.236(q)(2)(i)]Compressor Components, Gas Service - Other
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)]0
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)]0
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)]0
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)]0
Component Type [98.236(q)(2)(i)]Non-Compressor Components, Gas Service - Valve
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)]3
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)]8784
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)]0.0978875
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)]3.1670466
Component Type [98.236(q)(2)(i)]Non-Compressor Components, Gas Service - Connector
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)]0
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)]0
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)]0
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)]0
Component Type [98.236(q)(2)(i)]Non-Compressor Components, Gas Service - Open-ended Line
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)]0
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)]0
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)]0
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)]0
Component Type [98.236(q)(2)(i)]Non-Compressor components, Gas Service - Pressure Relief Valve
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)]0
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)]0
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)]0
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)]0
Component Type [98.236(q)(2)(i)]Non-Compressor components, Gas Service - Meter or Instrument
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)]1
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)]8784
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)]0.0148915
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)]0.4817989
Component Type [98.236(q)(2)(i)]Non-Compressor components, Gas Service - Other
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)]0
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)]0
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)]0
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)]0