Unit Name : GP-3 Germantown Boiler
Unit Type : OB (Boiler, other)
Unit Description :
Individual Unit Details:
Use Ivt Indicator: Y
Maximum Rated Heat Input Capacity:
1.01
(mmBtu/hr)
Emission Details:
Annual CO2 mass emissions from sorbent: 0 (Metric Tons)
Annual Biogenic CO2 Emissions:
0
(metric tons)
Tier Fuel Details:
Fuel :
Natural Gas (Weighted U.S. Average)
Tier Name :
Tier 1 (Equation C-1)
Tier Methodology Start Date :
2020-01-01
Tier Methodology End Date :
2020-12-31
Fuel Emission Details :
Total CO2 emissions | Total CH4 emissions | Total N2O emissions | Total CH4 emissions CO2e | Total N2O emissions CO2e |
20.5
(Metric Tons)
|
0.00
(Metric Tons)
|
0.000
(Metric Tons)
|
0
(Metric Tons)
|
0
(Metric Tons)
|
Fuel :
Distillate Fuel Oil No. 2
Tier Name :
Tier 1 (Equation C-1)
Tier Methodology Start Date :
2020-01-01
Tier Methodology End Date :
2020-12-31
Fuel Emission Details :
Total CO2 emissions | Total CH4 emissions | Total N2O emissions | Total CH4 emissions CO2e | Total N2O emissions CO2e |
0
(Metric Tons)
|
0
(Metric Tons)
|
0
(Metric Tons)
|
0
(Metric Tons)
|
0
(Metric Tons)
|
Unit Name : GP-1 HSC Boilers #1, #2, and #3
Unit Type : OCS (Other combustion source)
Unit Description :
Other Unit Name :
Small Unit Aggregation Details:
Use Ivt Indicator: Y
Highest Maximum Rated Heat Input Capacity:
76.4
Cumulative Maximum Rated Heat Input Capacity:
229.2
Emission Details:
Annual CO2 mass emissions from sorbent: 0 (Metric Tons)
Annual Biogenic CO2 Emissions:
0
(metric tons)
Annual Fossil fuel based CO2 Emissions:
27986.4
(metric tons)
Tier Fuel Details:
Fuel :
Natural Gas (Weighted U.S. Average)
Tier Name :
Tier 1 (Equation C-1)
Tier Methodology Start Date :
2020-01-01
Tier Methodology End Date :
2020-12-31
Fuel Emission Details :
Total CO2 emissions | Total CH4 emissions | Total N2O emissions | Total CH4 emissions CO2e | Total N2O emissions CO2e |
27860.5
(Metric Tons)
|
0.53
(Metric Tons)
|
0.053
(Metric Tons)
|
13.1
(Metric Tons)
|
15.6
(Metric Tons)
|
Fuel :
Distillate Fuel Oil No. 2
Tier Name :
Tier 1 (Equation C-1)
Tier Methodology Start Date :
2020-01-01
Tier Methodology End Date :
2020-12-31
Fuel Emission Details :
Total CO2 emissions | Total CH4 emissions | Total N2O emissions | Total CH4 emissions CO2e | Total N2O emissions CO2e |
125.8
(Metric Tons)
|
0.01
(Metric Tons)
|
0.001
(Metric Tons)
|
0.1
(Metric Tons)
|
0.3
(Metric Tons)
|
Unit Name : GP-2 Ford Building Boiler
Unit Type : OB (Boiler, other)
Unit Description :
Individual Unit Details:
Use Ivt Indicator: Y
Maximum Rated Heat Input Capacity:
0.947
(mmBtu/hr)
Emission Details:
Annual CO2 mass emissions from sorbent: 0 (Metric Tons)
Annual Biogenic CO2 Emissions:
0
(metric tons)
Tier Fuel Details:
Fuel :
Natural Gas (Weighted U.S. Average)
Tier Name :
Tier 1 (Equation C-1)
Tier Methodology Start Date :
2020-01-01
Tier Methodology End Date :
2020-12-31
Fuel Emission Details :
Total CO2 emissions | Total CH4 emissions | Total N2O emissions | Total CH4 emissions CO2e | Total N2O emissions CO2e |
31.4
(Metric Tons)
|
0.00
(Metric Tons)
|
0.000
(Metric Tons)
|
0
(Metric Tons)
|
0
(Metric Tons)
|