Source Reporting Form | Onshore Production [98.236(aa)(1)] |
Required for Selected Industry Segment | No |
Source Reporting Form | Facility Overview [98.236(aa)(2-11)] |
Required for Selected Industry Segment | Yes |
Source Reporting Form | Natural Gas Pneumatic Devices [98.236(b)] |
Required for Selected Industry Segment | Yes |
Total Reported CO2 Emissions (mt CO2) | 0.4 |
Total Reported CH4 Emissions (mt CH4) | 12.75 |
Source Reporting Form | Natural Gas Driven Pneumatic Pumps [98.236(c)] |
Required for Selected Industry Segment | No |
Total Reported CO2 Emissions (mt CO2) | 0.0 |
Total Reported CH4 Emissions (mt CH4) | 0.00 |
Source Reporting Form | Acid Gas Removal Units [98.236(d)] |
Required for Selected Industry Segment | No |
Total Reported CO2 Emissions (mt CO2) | 0.0 |
Source Reporting Form | Dehydrators [98.236(e)] |
Required for Selected Industry Segment | No |
Total Reported CO2 Emissions (mt CO2) | 0.0 |
Total Reported CH4 Emissions (mt CH4) | 0.00 |
Total Reported N2O Emissions (mt N2O) | 0.000 |
Source Reporting Form | Well Venting for Liquids Unloading [98.236(f)] |
Required for Selected Industry Segment | No |
Total Reported CO2 Emissions (mt CO2) | 0.0 |
Total Reported CH4 Emissions (mt CH4) | 0.00 |
Source Reporting Form | Completions and Workovers with Hydraulic Fracturing [98.236(g)] |
Required for Selected Industry Segment | No |
Total Reported CO2 Emissions (mt CO2) | 0.0 |
Total Reported CH4 Emissions (mt CH4) | 0.00 |
Total Reported N2O Emissions (mt N2O) | 0.000 |
Source Reporting Form | Completions and Workovers without Hydraulic Fracturing [98.236(h)] |
Required for Selected Industry Segment | No |
Total Reported CO2 Emissions (mt CO2) | 0.0 |
Total Reported CH4 Emissions (mt CH4) | 0.00 |
Total Reported N2O Emissions (mt N2O) | 0.000 |
Source Reporting Form | Blowdown Vent Stacks [98.236(i)] |
Required for Selected Industry Segment | No |
Total Reported CO2 Emissions (mt CO2) | 0.0 |
Total Reported CH4 Emissions (mt CH4) | 0.00 |
Source Reporting Form | Atmospheric Storage Tanks [98.236(j)] |
Required for Selected Industry Segment | No |
Total Reported CO2 Emissions (mt CO2) | 0.0 |
Total Reported CH4 Emissions (mt CH4) | 0.00 |
Total Reported N2O Emissions (mt N2O) | 0.000 |
Source Reporting Form | Transmission Storage Tanks [98.236(k)] |
Required for Selected Industry Segment | No |
Total Reported CO2 Emissions (mt CO2) | 0.0 |
Total Reported CH4 Emissions (mt CH4) | 0.00 |
Total Reported N2O Emissions (mt N2O) | 0.000 |
Source Reporting Form | Well Testing [98.236(l)] |
Required for Selected Industry Segment | No |
Total Reported CO2 Emissions (mt CO2) | 0.0 |
Total Reported CH4 Emissions (mt CH4) | 0.00 |
Total Reported N2O Emissions (mt N2O) | 0.000 |
Source Reporting Form | Associated Gas Venting and Flaring [98.236(m)] |
Required for Selected Industry Segment | No |
Total Reported CO2 Emissions (mt CO2) | 0.0 |
Total Reported CH4 Emissions (mt CH4) | 0.00 |
Total Reported N2O Emissions (mt N2O) | 0.000 |
Source Reporting Form | Flare Stacks [98.236(n)] |
Required for Selected Industry Segment | Yes |
Total Reported CO2 Emissions (mt CO2) | 0.0 |
Total Reported CH4 Emissions (mt CH4) | 0.00 |
Total Reported N2O Emissions (mt N2O) | 0.000 |
Source Reporting Form | Centrifugal Compressors [98.236(o)] |
Required for Selected Industry Segment | Yes |
Total Reported CO2 Emissions (mt CO2) | 0.0 |
Total Reported CH4 Emissions (mt CH4) | 0.00 |
Source Reporting Form | Reciprocating Compressors [98.236(p)] |
Required for Selected Industry Segment | Yes |
Total Reported CO2 Emissions (mt CO2) | 5.7 |
Total Reported CH4 Emissions (mt CH4) | 196.13 |
Source Reporting Form | Equipment Leaks Surveys and Population Counts [98.236(q,r)] |
Required for Selected Industry Segment | Yes |
Total Reported CO2 Emissions (mt CO2) | 5.2 |
Total Reported CH4 Emissions (mt CH4) | 169.18 |
Source Reporting Form | Offshore Petroleum and Natural Gas Production [98.236(s)] |
Required for Selected Industry Segment | No |
Total Reported CO2 Emissions (mt CO2) | 0.0 |
Total Reported CH4 Emissions (mt CH4) | 0.00 |
Total Reported N2O Emissions (mt N2O) | 0.000 |
Source Reporting Form | Enhanced Oil Recovery Injection Pumps [98.236(w)] |
Required for Selected Industry Segment | No |
Total Reported CO2 Emissions (mt CO2) | 0.0 |
Source Reporting Form | Enhanced Oil Recovery Hydrocarbon Liquids [98.236(x)] |
Required for Selected Industry Segment | No |
Total Reported CO2 Emissions (mt CO2) | 0.0 |
Source Reporting Form | Combustion Equipment at Onshore Petroleum and Natural Gas Production Facilities, Onshore Petroleum and Natural Gas Gathering and Boosting Facilities, and Natural gas Distribution Facilities [98.236(z)] |
Required for Selected Industry Segment | No |
Total Reported CO2 Emissions (mt CO2) | 0.0 |
Total Reported CH4 Emissions (mt CH4) | 0.00 |
Total Reported N2O Emissions (mt N2O) | 0.000 |
Unique name or ID for reciprocating compressor [98.236(p)(1)(i)] | E1 |
Total time in operating-mode (hours) [98.236(p)(1)(ii)] | 3900.09 |
Total time in standby-pressurized-mode (hours) [98.236(p)(1)(iii)] | 2838.1 |
Total time in not-operating-depressurized-mode (hours) [98.236(p)(1)(iv)] | 2045.81 |
Compressor measured in operating-mode? [98.236(p)(1)(v)] | No |
Compressor measured in standby-pressurized-mode? [98.236(p)(1)(vi)] | Yes |
Compressor measured in not-operating-depressurized-mode? [98.236(p)(1)(vii)] | No |
Compressor had blind flanges installed? [98.236(p)(1)(xii)] | No |
Power output of compressor driver (hp) [98.236(p)(1)(xiii)] | 2000 |
Compressor had scheduled depressurized shutdown during reporting year? [98.236(p)(1)(xiv)] | Yes |
Unique name or ID for reciprocating compressor [98.236(p)(1)(i)] | E2 |
Total time in operating-mode (hours) [98.236(p)(1)(ii)] | 3052.2 |
Total time in standby-pressurized-mode (hours) [98.236(p)(1)(iii)] | 4131.41 |
Total time in not-operating-depressurized-mode (hours) [98.236(p)(1)(iv)] | 1600.39 |
Compressor measured in operating-mode? [98.236(p)(1)(v)] | No |
Compressor measured in standby-pressurized-mode? [98.236(p)(1)(vi)] | Yes |
Compressor measured in not-operating-depressurized-mode? [98.236(p)(1)(vii)] | No |
Compressor had blind flanges installed? [98.236(p)(1)(xii)] | No |
Power output of compressor driver (hp) [98.236(p)(1)(xiii)] | 2000 |
Compressor had scheduled depressurized shutdown during reporting year? [98.236(p)(1)(xiv)] | Yes |
Unique name or ID for reciprocating compressor [98.236(p)(1)(i)] | E3 |
Total time in operating-mode (hours) [98.236(p)(1)(ii)] | 3557.93 |
Total time in standby-pressurized-mode (hours) [98.236(p)(1)(iii)] | 3884.66 |
Total time in not-operating-depressurized-mode (hours) [98.236(p)(1)(iv)] | 1341.41 |
Compressor measured in operating-mode? [98.236(p)(1)(v)] | No |
Compressor measured in standby-pressurized-mode? [98.236(p)(1)(vi)] | Yes |
Compressor measured in not-operating-depressurized-mode? [98.236(p)(1)(vii)] | No |
Compressor had blind flanges installed? [98.236(p)(1)(xii)] | No |
Power output of compressor driver (hp) [98.236(p)(1)(xiii)] | 1000 |
Compressor had scheduled depressurized shutdown during reporting year? [98.236(p)(1)(xiv)] | Yes |
Unique name or ID for reciprocating compressor [98.236(p)(1)(i)] | E4 |
Total time in operating-mode (hours) [98.236(p)(1)(ii)] | 3601.84 |
Total time in standby-pressurized-mode (hours) [98.236(p)(1)(iii)] | 3841.81 |
Total time in not-operating-depressurized-mode (hours) [98.236(p)(1)(iv)] | 1340.35 |
Compressor measured in operating-mode? [98.236(p)(1)(v)] | No |
Compressor measured in standby-pressurized-mode? [98.236(p)(1)(vi)] | No |
Compressor measured in not-operating-depressurized-mode? [98.236(p)(1)(vii)] | Yes |
Compressor had blind flanges installed? [98.236(p)(1)(xii)] | No |
Power output of compressor driver (hp) [98.236(p)(1)(xiii)] | 1000 |
Compressor had scheduled depressurized shutdown during reporting year? [98.236(p)(1)(xiv)] | Yes |
Unique name or ID for reciprocating compressor [98.236(p)(1)(i)] | E5 |
Total time in operating-mode (hours) [98.236(p)(1)(ii)] | 3138.27 |
Total time in standby-pressurized-mode (hours) [98.236(p)(1)(iii)] | 3722.59 |
Total time in not-operating-depressurized-mode (hours) [98.236(p)(1)(iv)] | 1923.14 |
Compressor measured in operating-mode? [98.236(p)(1)(v)] | No |
Compressor measured in standby-pressurized-mode? [98.236(p)(1)(vi)] | Yes |
Compressor measured in not-operating-depressurized-mode? [98.236(p)(1)(vii)] | No |
Compressor had blind flanges installed? [98.236(p)(1)(xii)] | No |
Power output of compressor driver (hp) [98.236(p)(1)(xiii)] | 1000 |
Compressor had scheduled depressurized shutdown during reporting year? [98.236(p)(1)(xiv)] | Yes |
Unique name or ID for reciprocating compressor [98.236(p)(1)(i)] | E6 |
Total time in operating-mode (hours) [98.236(p)(1)(ii)] | 3083.59 |
Total time in standby-pressurized-mode (hours) [98.236(p)(1)(iii)] | 3315.22 |
Total time in not-operating-depressurized-mode (hours) [98.236(p)(1)(iv)] | 2385.19 |
Compressor measured in operating-mode? [98.236(p)(1)(v)] | No |
Compressor measured in standby-pressurized-mode? [98.236(p)(1)(vi)] | Yes |
Compressor measured in not-operating-depressurized-mode? [98.236(p)(1)(vii)] | No |
Compressor had blind flanges installed? [98.236(p)(1)(xii)] | No |
Power output of compressor driver (hp) [98.236(p)(1)(xiii)] | 2000 |
Compressor had scheduled depressurized shutdown during reporting year? [98.236(p)(1)(xiv)] | Yes |
Unique name or ID for reciprocating compressor [98.236(p)(1)(i)] | E7 |
Total time in operating-mode (hours) [98.236(p)(1)(ii)] | 0.35 |
Total time in standby-pressurized-mode (hours) [98.236(p)(1)(iii)] | 1990.93 |
Total time in not-operating-depressurized-mode (hours) [98.236(p)(1)(iv)] | 6792.72 |
Compressor measured in operating-mode? [98.236(p)(1)(v)] | No |
Compressor measured in standby-pressurized-mode? [98.236(p)(1)(vi)] | No |
Compressor measured in not-operating-depressurized-mode? [98.236(p)(1)(vii)] | Yes |
Compressor had blind flanges installed? [98.236(p)(1)(xii)] | No |
Power output of compressor driver (hp) [98.236(p)(1)(xiii)] | 2000 |
Compressor had scheduled depressurized shutdown during reporting year? [98.236(p)(1)(xiv)] | Yes |
Unique name or ID for reciprocating compressor [98.236(p)(1)(i)] | E8 |
Total time in operating-mode (hours) [98.236(p)(1)(ii)] | 3638.64 |
Total time in standby-pressurized-mode (hours) [98.236(p)(1)(iii)] | 3063.51 |
Total time in not-operating-depressurized-mode (hours) [98.236(p)(1)(iv)] | 2081.85 |
Compressor measured in operating-mode? [98.236(p)(1)(v)] | No |
Compressor measured in standby-pressurized-mode? [98.236(p)(1)(vi)] | Yes |
Compressor measured in not-operating-depressurized-mode? [98.236(p)(1)(vii)] | No |
Compressor had blind flanges installed? [98.236(p)(1)(xii)] | No |
Power output of compressor driver (hp) [98.236(p)(1)(xiii)] | 2000 |
Compressor had scheduled depressurized shutdown during reporting year? [98.236(p)(1)(xiv)] | Yes |
Unique name or ID for reciprocating compressor [98.236(p)(1)(i)] | E9 |
Total time in operating-mode (hours) [98.236(p)(1)(ii)] | 3403.42 |
Total time in standby-pressurized-mode (hours) [98.236(p)(1)(iii)] | 2027.37 |
Total time in not-operating-depressurized-mode (hours) [98.236(p)(1)(iv)] | 3353.21 |
Compressor measured in operating-mode? [98.236(p)(1)(v)] | No |
Compressor measured in standby-pressurized-mode? [98.236(p)(1)(vi)] | Yes |
Compressor measured in not-operating-depressurized-mode? [98.236(p)(1)(vii)] | No |
Compressor had blind flanges installed? [98.236(p)(1)(xii)] | No |
Power output of compressor driver (hp) [98.236(p)(1)(xiii)] | 2000 |
Compressor had scheduled depressurized shutdown during reporting year? [98.236(p)(1)(xiv)] | Yes |
Unique name or ID for reciprocating compressor [98.236(p)(1)(i)] | E10 |
Total time in operating-mode (hours) [98.236(p)(1)(ii)] | 445.61 |
Total time in standby-pressurized-mode (hours) [98.236(p)(1)(iii)] | 7784.44 |
Total time in not-operating-depressurized-mode (hours) [98.236(p)(1)(iv)] | 553.95 |
Compressor measured in operating-mode? [98.236(p)(1)(v)] | No |
Compressor measured in standby-pressurized-mode? [98.236(p)(1)(vi)] | No |
Compressor measured in not-operating-depressurized-mode? [98.236(p)(1)(vii)] | Yes |
Compressor had blind flanges installed? [98.236(p)(1)(xii)] | No |
Power output of compressor driver (hp) [98.236(p)(1)(xiii)] | 2000 |
Compressor had scheduled depressurized shutdown during reporting year? [98.236(p)(1)(xiv)] | Yes |
Unique name or ID for reciprocating compressor [98.236(p)(1)(i)] | E11 |
Total time in operating-mode (hours) [98.236(p)(1)(ii)] | 1508.71 |
Total time in standby-pressurized-mode (hours) [98.236(p)(1)(iii)] | 1272.85 |
Total time in not-operating-depressurized-mode (hours) [98.236(p)(1)(iv)] | 6002.44 |
Compressor measured in operating-mode? [98.236(p)(1)(v)] | No |
Compressor measured in standby-pressurized-mode? [98.236(p)(1)(vi)] | Yes |
Compressor measured in not-operating-depressurized-mode? [98.236(p)(1)(vii)] | No |
Compressor had blind flanges installed? [98.236(p)(1)(xii)] | No |
Power output of compressor driver (hp) [98.236(p)(1)(xiii)] | 2000 |
Compressor had scheduled depressurized shutdown during reporting year? [98.236(p)(1)(xiv)] | Yes |
Unique name or ID for reciprocating compressor [98.236(p)(1)(i)] | E12 |
Total time in operating-mode (hours) [98.236(p)(1)(ii)] | 3451.23 |
Total time in standby-pressurized-mode (hours) [98.236(p)(1)(iii)] | 2762.61 |
Total time in not-operating-depressurized-mode (hours) [98.236(p)(1)(iv)] | 2570.16 |
Compressor measured in operating-mode? [98.236(p)(1)(v)] | No |
Compressor measured in standby-pressurized-mode? [98.236(p)(1)(vi)] | Yes |
Compressor measured in not-operating-depressurized-mode? [98.236(p)(1)(vii)] | No |
Compressor had blind flanges installed? [98.236(p)(1)(xii)] | No |
Power output of compressor driver (hp) [98.236(p)(1)(xiii)] | 3400 |
Compressor had scheduled depressurized shutdown during reporting year? [98.236(p)(1)(xiv)] | Yes |
Unique name or ID for reciprocating compressor [98.236(p)(1)(i)] | E13 |
Total time in operating-mode (hours) [98.236(p)(1)(ii)] | 3718.8 |
Total time in standby-pressurized-mode (hours) [98.236(p)(1)(iii)] | 2172.86 |
Total time in not-operating-depressurized-mode (hours) [98.236(p)(1)(iv)] | 2892.34 |
Compressor measured in operating-mode? [98.236(p)(1)(v)] | No |
Compressor measured in standby-pressurized-mode? [98.236(p)(1)(vi)] | Yes |
Compressor measured in not-operating-depressurized-mode? [98.236(p)(1)(vii)] | No |
Compressor had blind flanges installed? [98.236(p)(1)(xii)] | No |
Power output of compressor driver (hp) [98.236(p)(1)(xiii)] | 3400 |
Compressor had scheduled depressurized shutdown during reporting year? [98.236(p)(1)(xiv)] | Yes |
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)] | E1 |
Reciprocating compressor source [98.236(p)(2)(i)(B)] | Blowdown valve |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | E1 BDV |
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)] | E1 |
Reciprocating compressor source [98.236(p)(2)(i)(B)] | Isolation valve |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | E1 ISO |
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)] | E1 |
Reciprocating compressor source [98.236(p)(2)(i)(B)] | Rod packing |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | E1 RPV |
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)] | E2 |
Reciprocating compressor source [98.236(p)(2)(i)(B)] | Blowdown valve |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | E2 BDV |
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)] | E2 |
Reciprocating compressor source [98.236(p)(2)(i)(B)] | Isolation valve |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | E2 ISO |
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)] | E2 |
Reciprocating compressor source [98.236(p)(2)(i)(B)] | Rod packing |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | E2 RPV |
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)] | E3 |
Reciprocating compressor source [98.236(p)(2)(i)(B)] | Blowdown valve |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | E3 BDV |
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)] | E3 |
Reciprocating compressor source [98.236(p)(2)(i)(B)] | Isolation valve |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | E3 ISO |
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)] | E3 |
Reciprocating compressor source [98.236(p)(2)(i)(B)] | Rod packing |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | E3 RPV |
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)] | E4 |
Reciprocating compressor source [98.236(p)(2)(i)(B)] | Blowdown valve |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | E4 BDV |
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)] | E4 |
Reciprocating compressor source [98.236(p)(2)(i)(B)] | Isolation valve |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | E4 ISO |
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)] | E4 |
Reciprocating compressor source [98.236(p)(2)(i)(B)] | Rod packing |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | E4 RPV |
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)] | E5 |
Reciprocating compressor source [98.236(p)(2)(i)(B)] | Blowdown valve |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | E5 BDV |
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)] | E5 |
Reciprocating compressor source [98.236(p)(2)(i)(B)] | Isolation valve |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | E5 ISO |
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)] | E5 |
Reciprocating compressor source [98.236(p)(2)(i)(B)] | Rod packing |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | E5 RPV |
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)] | E6 |
Reciprocating compressor source [98.236(p)(2)(i)(B)] | Blowdown valve |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | E6 BDV |
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)] | E6 |
Reciprocating compressor source [98.236(p)(2)(i)(B)] | Isolation valve |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | E6 ISO |
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)] | E6 |
Reciprocating compressor source [98.236(p)(2)(i)(B)] | Rod packing |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | E6 RPV |
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)] | E7 |
Reciprocating compressor source [98.236(p)(2)(i)(B)] | Blowdown valve |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | E7 BDV |
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)] | E7 |
Reciprocating compressor source [98.236(p)(2)(i)(B)] | Isolation valve |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | E7 ISO |
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)] | E7 |
Reciprocating compressor source [98.236(p)(2)(i)(B)] | Rod packing |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | E7 RPV |
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)] | E8 |
Reciprocating compressor source [98.236(p)(2)(i)(B)] | Blowdown valve |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | E8 BDV |
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)] | E8 |
Reciprocating compressor source [98.236(p)(2)(i)(B)] | Isolation valve |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | E8 ISO |
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)] | E8 |
Reciprocating compressor source [98.236(p)(2)(i)(B)] | Rod packing |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | E8 RPV |
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)] | E9 |
Reciprocating compressor source [98.236(p)(2)(i)(B)] | Blowdown valve |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | E9 BDV |
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)] | E9 |
Reciprocating compressor source [98.236(p)(2)(i)(B)] | Isolation valve |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | E9 ISO |
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)] | E9 |
Reciprocating compressor source [98.236(p)(2)(i)(B)] | Rod packing |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | E9 RPV |
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)] | E10 |
Reciprocating compressor source [98.236(p)(2)(i)(B)] | Blowdown valve |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | E10 BDV |
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)] | E10 |
Reciprocating compressor source [98.236(p)(2)(i)(B)] | Isolation valve |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | E10 ISO |
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)] | E10 |
Reciprocating compressor source [98.236(p)(2)(i)(B)] | Rod packing |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | E10 RPV |
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)] | E11 |
Reciprocating compressor source [98.236(p)(2)(i)(B)] | Blowdown valve |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | E11 BDV |
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)] | E11 |
Reciprocating compressor source [98.236(p)(2)(i)(B)] | Isolation valve |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | E11 ISO |
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)] | E11 |
Reciprocating compressor source [98.236(p)(2)(i)(B)] | Rod packing |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | E11 RPV |
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)] | E12 |
Reciprocating compressor source [98.236(p)(2)(i)(B)] | Blowdown valve |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | E12 BDV |
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)] | E12 |
Reciprocating compressor source [98.236(p)(2)(i)(B)] | Isolation valve |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | E12 ISO |
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)] | E12 |
Reciprocating compressor source [98.236(p)(2)(i)(B)] | Rod packing |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | E12 RPV |
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)] | E13 |
Reciprocating compressor source [98.236(p)(2)(i)(B)] | Blowdown valve |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | E13 BDV |
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)] | E13 |
Reciprocating compressor source [98.236(p)(2)(i)(B)] | Isolation valve |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | E13 ISO |
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)] | E13 |
Reciprocating compressor source [98.236(p)(2)(i)(B)] | Rod packing |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | E13 RPV |
Unique Name or ID for leak or vent (Specify) [98.236(p)(2)(i)(C)] [98.236(p)(3)(i)(A)] | E1 BDV |
Measurement date (mm/dd/yyyy) [98.236(p)(3)(i)(B)] | 2020-05-18 |
Measurement method [98.236(p)(3)(i)(C)] | Acoustic leak detection |
Measured flow rate (standard cubic feet/hour) [98.236(p)(3)(i)(D)] | 317.242 |
Is the measurement location prior to or after commingling with non-compressor emission sources? [98.236(p)(3)(i)(F)] | Prior to commingling |
Compressors in *Standby-pressurized mode* | E1 |
Unique Name or ID for leak or vent (Specify) [98.236(p)(2)(i)(C)] [98.236(p)(3)(i)(A)] | E2 BDV |
Measurement date (mm/dd/yyyy) [98.236(p)(3)(i)(B)] | 2020-05-18 |
Measurement method [98.236(p)(3)(i)(C)] | Acoustic leak detection |
Measured flow rate (standard cubic feet/hour) [98.236(p)(3)(i)(D)] | 382.392 |
Is the measurement location prior to or after commingling with non-compressor emission sources? [98.236(p)(3)(i)(F)] | Prior to commingling |
Compressors in *Standby-pressurized mode* | E2 |
Unique Name or ID for leak or vent (Specify) [98.236(p)(2)(i)(C)] [98.236(p)(3)(i)(A)] | E3 BDV |
Measurement date (mm/dd/yyyy) [98.236(p)(3)(i)(B)] | 2020-05-18 |
Measurement method [98.236(p)(3)(i)(C)] | Acoustic leak detection |
Measured flow rate (standard cubic feet/hour) [98.236(p)(3)(i)(D)] | 152.956 |
Is the measurement location prior to or after commingling with non-compressor emission sources? [98.236(p)(3)(i)(F)] | Prior to commingling |
Compressors in *Standby-pressurized mode* | E3 |
Unique Name or ID for leak or vent (Specify) [98.236(p)(2)(i)(C)] [98.236(p)(3)(i)(A)] | E4 ISO |
Measurement date (mm/dd/yyyy) [98.236(p)(3)(i)(B)] | 2020-05-18 |
Measurement method [98.236(p)(3)(i)(C)] | Acoustic leak detection |
Measured flow rate (standard cubic feet/hour) [98.236(p)(3)(i)(D)] | 82.089 |
Is the measurement location prior to or after commingling with non-compressor emission sources? [98.236(p)(3)(i)(F)] | Prior to commingling |
Compressors in “Not-operating mode” | E4 |
Unique Name or ID for leak or vent (Specify) [98.236(p)(2)(i)(C)] [98.236(p)(3)(i)(A)] | E5 BDV |
Measurement date (mm/dd/yyyy) [98.236(p)(3)(i)(B)] | 2020-05-18 |
Measurement method [98.236(p)(3)(i)(C)] | Acoustic leak detection |
Measured flow rate (standard cubic feet/hour) [98.236(p)(3)(i)(D)] | 99.138 |
Is the measurement location prior to or after commingling with non-compressor emission sources? [98.236(p)(3)(i)(F)] | Prior to commingling |
Compressors in *Standby-pressurized mode* | E5 |
Unique Name or ID for leak or vent (Specify) [98.236(p)(2)(i)(C)] [98.236(p)(3)(i)(A)] | E6 BDV |
Measurement date (mm/dd/yyyy) [98.236(p)(3)(i)(B)] | 2020-05-18 |
Measurement method [98.236(p)(3)(i)(C)] | Acoustic leak detection |
Measured flow rate (standard cubic feet/hour) [98.236(p)(3)(i)(D)] | 283.252 |
Is the measurement location prior to or after commingling with non-compressor emission sources? [98.236(p)(3)(i)(F)] | Prior to commingling |
Compressors in *Standby-pressurized mode* | E6 |
Unique Name or ID for leak or vent (Specify) [98.236(p)(2)(i)(C)] [98.236(p)(3)(i)(A)] | E7 ISO |
Measurement date (mm/dd/yyyy) [98.236(p)(3)(i)(B)] | 2020-05-18 |
Measurement method [98.236(p)(3)(i)(C)] | Acoustic leak detection |
Measured flow rate (standard cubic feet/hour) [98.236(p)(3)(i)(D)] | 62.316 |
Is the measurement location prior to or after commingling with non-compressor emission sources? [98.236(p)(3)(i)(F)] | Prior to commingling |
Compressors in “Not-operating mode” | E7 |
Unique Name or ID for leak or vent (Specify) [98.236(p)(2)(i)(C)] [98.236(p)(3)(i)(A)] | E8 BDV |
Measurement date (mm/dd/yyyy) [98.236(p)(3)(i)(B)] | 2020-05-18 |
Measurement method [98.236(p)(3)(i)(C)] | Acoustic leak detection |
Measured flow rate (standard cubic feet/hour) [98.236(p)(3)(i)(D)] | 104.803 |
Is the measurement location prior to or after commingling with non-compressor emission sources? [98.236(p)(3)(i)(F)] | Prior to commingling |
Compressors in *Standby-pressurized mode* | E8 |
Unique Name or ID for leak or vent (Specify) [98.236(p)(2)(i)(C)] [98.236(p)(3)(i)(A)] | E9 BDV |
Measurement date (mm/dd/yyyy) [98.236(p)(3)(i)(B)] | 2020-05-18 |
Measurement method [98.236(p)(3)(i)(C)] | Acoustic leak detection |
Measured flow rate (standard cubic feet/hour) [98.236(p)(3)(i)(D)] | 90.585 |
Is the measurement location prior to or after commingling with non-compressor emission sources? [98.236(p)(3)(i)(F)] | Prior to commingling |
Compressors in *Standby-pressurized mode* | E9 |
Unique Name or ID for leak or vent (Specify) [98.236(p)(2)(i)(C)] [98.236(p)(3)(i)(A)] | E10 ISO |
Measurement date (mm/dd/yyyy) [98.236(p)(3)(i)(B)] | 2020-05-18 |
Measurement method [98.236(p)(3)(i)(C)] | Screening/Optical gas imaging |
Measured flow rate (standard cubic feet/hour) [98.236(p)(3)(i)(D)] | 0 |
Is the measurement location prior to or after commingling with non-compressor emission sources? [98.236(p)(3)(i)(F)] | Prior to commingling |
Compressors in “Not-operating mode” | E10 |
Unique Name or ID for leak or vent (Specify) [98.236(p)(2)(i)(C)] [98.236(p)(3)(i)(A)] | E11 BDV |
Measurement date (mm/dd/yyyy) [98.236(p)(3)(i)(B)] | 2020-05-18 |
Measurement method [98.236(p)(3)(i)(C)] | Screening/Optical gas imaging |
Measured flow rate (standard cubic feet/hour) [98.236(p)(3)(i)(D)] | 0 |
Is the measurement location prior to or after commingling with non-compressor emission sources? [98.236(p)(3)(i)(F)] | Prior to commingling |
Compressors in *Standby-pressurized mode* | E11 |
Unique Name or ID for leak or vent (Specify) [98.236(p)(2)(i)(C)] [98.236(p)(3)(i)(A)] | E12 BDV |
Measurement date (mm/dd/yyyy) [98.236(p)(3)(i)(B)] | 2020-05-18 |
Measurement method [98.236(p)(3)(i)(C)] | Screening/Optical gas imaging |
Measured flow rate (standard cubic feet/hour) [98.236(p)(3)(i)(D)] | 0 |
Is the measurement location prior to or after commingling with non-compressor emission sources? [98.236(p)(3)(i)(F)] | Prior to commingling |
Compressors in *Standby-pressurized mode* | E12 |
Unique Name or ID for leak or vent (Specify) [98.236(p)(2)(i)(C)] [98.236(p)(3)(i)(A)] | E13 BDV |
Measurement date (mm/dd/yyyy) [98.236(p)(3)(i)(B)] | 2020-05-18 |
Measurement method [98.236(p)(3)(i)(C)] | Screening/Optical gas imaging |
Measured flow rate (standard cubic feet/hour) [98.236(p)(3)(i)(D)] | 0 |
Is the measurement location prior to or after commingling with non-compressor emission sources? [98.236(p)(3)(i)(F)] | Prior to commingling |
Compressors in *Standby-pressurized mode* | E13 |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | E1 BDV |
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)] | Manifold |
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)] | Atmosphere |
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)] | Yes |
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)] | No |
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)] | 0.5042392 |
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)] | 17.4854061 |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | E1 ISO |
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)] | Manifold |
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)] | Atmosphere |
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)] | No |
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)] | No |
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)] | 0.04322 |
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)] | 1.4987318 |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | E1 RPV |
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)] | Manifold |
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)] | Atmosphere |
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)] | No |
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)] | No |
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)] | 0.1897592 |
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)] | 6.5802443 |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | E2 BDV |
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)] | Manifold |
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)] | Atmosphere |
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)] | Yes |
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)] | No |
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)] | 0.854969 |
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)] | 29.6475937 |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | E2 ISO |
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)] | Manifold |
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)] | Atmosphere |
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)] | No |
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)] | No |
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)] | 0.03381 |
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)] | 1.1724233 |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | E2 RPV |
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)] | Manifold |
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)] | Atmosphere |
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)] | No |
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)] | No |
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)] | 0.1485051 |
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)] | 5.1496816 |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | E3 BDV |
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)] | Manifold |
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)] | Atmosphere |
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)] | Yes |
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)] | No |
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)] | 0.3404985 |
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)] | 11.8074008 |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | E3 ISO |
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)] | Manifold |
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)] | Atmosphere |
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)] | No |
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)] | No |
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)] | 0.0283388 |
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)] | 0.9826982 |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | E3 RPV |
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)] | Manifold |
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)] | Atmosphere |
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)] | No |
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)] | No |
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)] | 0.1731114 |
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)] | 6.0029508 |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | E4 BDV |
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)] | Manifold |
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)] | Atmosphere |
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)] | No |
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)] | No |
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)] | 0.0814778 |
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)] | 2.8253915 |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | E4 ISO |
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)] | Manifold |
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)] | Atmosphere |
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)] | Yes |
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)] | No |
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)] | 0.0578747 |
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)] | 2.0069106 |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | E4 RPV |
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)] | Manifold |
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)] | Atmosphere |
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)] | No |
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)] | No |
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)] | 0.1752479 |
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)] | 6.0770359 |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | E5 BDV |
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)] | Manifold |
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)] | Atmosphere |
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)] | Yes |
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)] | No |
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)] | 0.2187814 |
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)] | 7.586639 |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | E5 ISO |
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)] | Manifold |
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)] | Atmosphere |
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)] | No |
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)] | No |
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)] | 0.0406285 |
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)] | 1.4088655 |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | E5 RPV |
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)] | Manifold |
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)] | Atmosphere |
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)] | No |
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)] | No |
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)] | 0.1526928 |
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)] | 5.2948991 |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | E6 BDV |
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)] | Manifold |
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)] | Atmosphere |
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)] | Yes |
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)] | No |
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)] | 0.5181678 |
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)] | 17.9684034 |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | E6 ISO |
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)] | Manifold |
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)] | Atmosphere |
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)] | No |
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)] | No |
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)] | 0.0503898 |
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)] | 1.7473569 |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | E6 RPV |
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)] | Manifold |
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)] | Atmosphere |
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)] | No |
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)] | No |
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)] | 0.1500324 |
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)] | 5.2026429 |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | E7 BDV |
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)] | Manifold |
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)] | Atmosphere |
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)] | No |
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)] | No |
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)] | 0.027559 |
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)] | 0.9556574 |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | E7 ISO |
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)] | Manifold |
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)] | Atmosphere |
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)] | Yes |
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)] | No |
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)] | 0.2226532 |
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)] | 7.7209033 |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | E7 RPV |
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)] | Manifold |
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)] | Atmosphere |
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)] | No |
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)] | No |
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)] | 0.000017 |
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)] | 0.0005905 |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | E8 BDV |
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)] | Manifold |
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)] | Atmosphere |
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)] | Yes |
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)] | No |
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)] | 0.1974732 |
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)] | 6.8477396 |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | E8 ISO |
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)] | Manifold |
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)] | Atmosphere |
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)] | No |
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)] | No |
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)] | 0.0439814 |
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)] | 1.5251342 |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | E8 RPV |
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)] | Manifold |
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)] | Atmosphere |
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)] | No |
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)] | No |
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)] | 0.1770384 |
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)] | 6.139125 |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | E9 BDV |
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)] | Manifold |
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)] | Atmosphere |
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)] | Yes |
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)] | No |
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)] | 0.1233441 |
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)] | 4.2771803 |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | E9 ISO |
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)] | Manifold |
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)] | Atmosphere |
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)] | No |
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)] | No |
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)] | 0.0708403 |
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)] | 2.4565148 |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | E9 RPV |
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)] | Manifold |
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)] | Atmosphere |
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)] | No |
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)] | No |
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)] | 0.1655937 |
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)] | 5.7422611 |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | E10 BDV |
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)] | Manifold |
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)] | Atmosphere |
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)] | No |
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)] | No |
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)] | 0.1112452 |
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)] | 3.8576281 |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | E10 ISO |
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)] | Manifold |
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)] | Atmosphere |
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)] | Yes |
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)] | No |
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)] | 0 |
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)] | 0 |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | E10 RPV |
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)] | Manifold |
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)] | Atmosphere |
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)] | No |
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)] | No |
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)] | 0.0216812 |
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)] | 0.7518346 |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | E11 BDV |
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)] | Manifold |
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)] | Atmosphere |
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)] | Yes |
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)] | No |
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)] | 0.0118557 |
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)] | 0.4111168 |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | E11 ISO |
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)] | Manifold |
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)] | Atmosphere |
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)] | No |
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)] | No |
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)] | 0.1268082 |
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)] | 4.3973037 |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | E11 RPV |
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)] | Manifold |
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)] | Atmosphere |
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)] | No |
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)] | No |
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)] | 0.0734064 |
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)] | 2.5455003 |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | E12 BDV |
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)] | Manifold |
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)] | Atmosphere |
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)] | Yes |
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)] | No |
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)] | 0.0271203 |
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)] | 0.9404449 |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | E12 ISO |
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)] | Manifold |
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)] | Atmosphere |
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)] | No |
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)] | No |
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)] | 0.0542975 |
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)] | 1.8828633 |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | E12 RPV |
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)] | Manifold |
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)] | Atmosphere |
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)] | No |
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)] | No |
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)] | 0.1679199 |
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)] | 5.8229263 |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | E13 BDV |
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)] | Manifold |
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)] | Atmosphere |
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)] | Yes |
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)] | No |
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)] | 0.0292229 |
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)] | 1.0133565 |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | E13 ISO |
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)] | Manifold |
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)] | Atmosphere |
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)] | No |
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)] | No |
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)] | 0.0611039 |
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)] | 2.1188879 |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | E13 RPV |
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)] | Manifold |
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)] | Atmosphere |
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)] | No |
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)] | No |
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)] | 0.1809386 |
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)] | 6.2743712 |
Source Reporting Form | Onshore Production [98.236(aa)(1)] |
Required for Selected Industry Segment | No |
Source Reporting Form | Facility Overview [98.236(aa)(2-11)] |
Required for Selected Industry Segment | Yes |
Source Reporting Form | Natural Gas Pneumatic Devices [98.236(b)] |
Required for Selected Industry Segment | Yes |
Total Reported CO2 Emissions (mt CO2) | 4.4 |
Total Reported CH4 Emissions (mt CH4) | 15.46 |
Source Reporting Form | Natural Gas Driven Pneumatic Pumps [98.236(c)] |
Required for Selected Industry Segment | No |
Total Reported CO2 Emissions (mt CO2) | 0.0 |
Total Reported CH4 Emissions (mt CH4) | 0.00 |
Source Reporting Form | Acid Gas Removal Units [98.236(d)] |
Required for Selected Industry Segment | No |
Total Reported CO2 Emissions (mt CO2) | 0.0 |
Source Reporting Form | Dehydrators [98.236(e)] |
Required for Selected Industry Segment | No |
Total Reported CO2 Emissions (mt CO2) | 0.0 |
Total Reported CH4 Emissions (mt CH4) | 0.00 |
Total Reported N2O Emissions (mt N2O) | 0.000 |
Source Reporting Form | Well Venting for Liquids Unloading [98.236(f)] |
Required for Selected Industry Segment | No |
Total Reported CO2 Emissions (mt CO2) | 0.0 |
Total Reported CH4 Emissions (mt CH4) | 0.00 |
Source Reporting Form | Completions and Workovers with Hydraulic Fracturing [98.236(g)] |
Required for Selected Industry Segment | No |
Total Reported CO2 Emissions (mt CO2) | 0.0 |
Total Reported CH4 Emissions (mt CH4) | 0.00 |
Total Reported N2O Emissions (mt N2O) | 0.000 |
Source Reporting Form | Completions and Workovers without Hydraulic Fracturing [98.236(h)] |
Required for Selected Industry Segment | No |
Total Reported CO2 Emissions (mt CO2) | 0.0 |
Total Reported CH4 Emissions (mt CH4) | 0.00 |
Total Reported N2O Emissions (mt N2O) | 0.000 |
Source Reporting Form | Blowdown Vent Stacks [98.236(i)] |
Required for Selected Industry Segment | Yes |
Total Reported CO2 Emissions (mt CO2) | 0.2 |
Total Reported CH4 Emissions (mt CH4) | 7.24 |
Source Reporting Form | Atmospheric Storage Tanks [98.236(j)] |
Required for Selected Industry Segment | No |
Total Reported CO2 Emissions (mt CO2) | 0.0 |
Total Reported CH4 Emissions (mt CH4) | 0.00 |
Total Reported N2O Emissions (mt N2O) | 0.000 |
Source Reporting Form | Transmission Storage Tanks [98.236(k)] |
Required for Selected Industry Segment | Yes |
Total Reported CO2 Emissions (mt CO2) | 0.0 |
Total Reported CH4 Emissions (mt CH4) | 0.00 |
Total Reported N2O Emissions (mt N2O) | 0.000 |
Source Reporting Form | Well Testing [98.236(l)] |
Required for Selected Industry Segment | No |
Total Reported CO2 Emissions (mt CO2) | 0.0 |
Total Reported CH4 Emissions (mt CH4) | 0.00 |
Total Reported N2O Emissions (mt N2O) | 0.000 |
Source Reporting Form | Associated Gas Venting and Flaring [98.236(m)] |
Required for Selected Industry Segment | No |
Total Reported CO2 Emissions (mt CO2) | 0.0 |
Total Reported CH4 Emissions (mt CH4) | 0.00 |
Total Reported N2O Emissions (mt N2O) | 0.000 |
Source Reporting Form | Flare Stacks [98.236(n)] |
Required for Selected Industry Segment | Yes |
Total Reported CO2 Emissions (mt CO2) | 0.0 |
Total Reported CH4 Emissions (mt CH4) | 0.00 |
Total Reported N2O Emissions (mt N2O) | 0.000 |
Source Reporting Form | Centrifugal Compressors [98.236(o)] |
Required for Selected Industry Segment | Yes |
Total Reported CO2 Emissions (mt CO2) | 0.0 |
Total Reported CH4 Emissions (mt CH4) | 1.52 |
Source Reporting Form | Reciprocating Compressors [98.236(p)] |
Required for Selected Industry Segment | Yes |
Total Reported CO2 Emissions (mt CO2) | 0.6 |
Total Reported CH4 Emissions (mt CH4) | 21.73 |
Source Reporting Form | Equipment Leaks Surveys and Population Counts [98.236(q,r)] |
Required for Selected Industry Segment | Yes |
Total Reported CO2 Emissions (mt CO2) | 0.2 |
Total Reported CH4 Emissions (mt CH4) | 5.26 |
Source Reporting Form | Offshore Petroleum and Natural Gas Production [98.236(s)] |
Required for Selected Industry Segment | No |
Total Reported CO2 Emissions (mt CO2) | 0.0 |
Total Reported CH4 Emissions (mt CH4) | 0.00 |
Total Reported N2O Emissions (mt N2O) | 0.000 |
Source Reporting Form | Enhanced Oil Recovery Injection Pumps [98.236(w)] |
Required for Selected Industry Segment | No |
Total Reported CO2 Emissions (mt CO2) | 0.0 |
Source Reporting Form | Enhanced Oil Recovery Hydrocarbon Liquids [98.236(x)] |
Required for Selected Industry Segment | No |
Total Reported CO2 Emissions (mt CO2) | 0.0 |
Source Reporting Form | Combustion Equipment at Onshore Petroleum and Natural Gas Production Facilities, Onshore Petroleum and Natural Gas Gathering and Boosting Facilities, and Natural gas Distribution Facilities [98.236(z)] |
Required for Selected Industry Segment | No |
Total Reported CO2 Emissions (mt CO2) | 0.0 |
Total Reported CH4 Emissions (mt CH4) | 0.00 |
Total Reported N2O Emissions (mt N2O) | 0.000 |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | E3 BDV |
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)] | Manifold |
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)] | Atmosphere |
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)] | No |
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)] | No |
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)] | 0.0112672 |
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)] | 0.3907105 |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | E3 ISO |
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)] | Manifold |
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)] | Atmosphere |
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)] | Yes |
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)] | No |
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)] | 0 |
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)] | 0 |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | E3 RPV |
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)] | Manifold |
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)] | Atmosphere |
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)] | No |
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)] | No |
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)] | 0.0005007 |
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)] | 0.0173613 |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | E4 BDV |
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)] | Manifold |
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)] | Atmosphere |
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)] | No |
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)] | No |
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)] | 0.0590842 |
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)] | 2.0488528 |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | E4 ISO |
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)] | Manifold |
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)] | Atmosphere |
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)] | Yes |
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)] | No |
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)] | 0 |
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)] | 0 |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | E4 RPV |
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)] | Manifold |
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)] | Atmosphere |
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)] | No |
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)] | No |
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)] | 0.0150743 |
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)] | 0.5227293 |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | E5 BDV |
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)] | Manifold |
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)] | Atmosphere |
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)] | Yes |
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)] | No |
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)] | 0.0139778 |
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)] | 0.4847044 |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | E5 ISO |
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)] | Manifold |
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)] | Atmosphere |
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)] | No |
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)] | No |
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)] | 0.1578687 |
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)] | 5.4743809 |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | E5 RPV |
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)] | Manifold |
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)] | Atmosphere |
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)] | Yes |
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)] | No |
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)] | 0.2472253 |
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)] | 8.5729852 |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | E6 BDV |
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)] | Manifold |
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)] | Atmosphere |
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)] | No |
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)] | No |
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)] | 0.1079741 |
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)] | 3.7441962 |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | E6 ISO |
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)] | Manifold |
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)] | Atmosphere |
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)] | Yes |
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)] | No |
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)] | 0 |
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)] | 0 |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | E6 RPV |
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)] | Manifold |
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)] | Atmosphere |
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)] | No |
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)] | No |
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)] | 0.0137509 |
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)] | 0.4768374 |
Component Type [98.236(q)(2)(i)] | Compressor Components, Gas Service - Valve |
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)] | 1 |
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)] | 8784 |
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)] | 0.0754231 |
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)] | 2.4402374 |
Component Type [98.236(q)(2)(i)] | Compressor Components, Gas Service - Connector |
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)] | 0 |
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)] | 8784 |
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)] | 0 |
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)] | 0 |
Component Type [98.236(q)(2)(i)] | Compressor Components, Gas Service - Open-ended Line |
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)] | 0 |
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)] | 8784 |
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)] | 0 |
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)] | 0 |
Component Type [98.236(q)(2)(i)] | Compressor Components, Gas Service - Pressure Relief Valve |
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)] | 0 |
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)] | 8784 |
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)] | 0 |
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)] | 0 |
Component Type [98.236(q)(2)(i)] | Compressor Components, Gas Service - Meter or Instrument |
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)] | 0 |
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)] | 8784 |
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)] | 0 |
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)] | 0 |
Component Type [98.236(q)(2)(i)] | Compressor Components, Gas Service - Other |
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)] | 0 |
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)] | 8784 |
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)] | 0 |
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)] | 0 |
Component Type [98.236(q)(2)(i)] | Non-Compressor Components, Gas Service - Valve |
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)] | 0 |
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)] | 8784 |
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)] | 0 |
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)] | 0 |
Component Type [98.236(q)(2)(i)] | Non-Compressor Components, Gas Service - Connector |
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)] | 3 |
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)] | 8784 |
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)] | 0.0870619 |
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)] | 2.8167969 |
Component Type [98.236(q)(2)(i)] | Non-Compressor Components, Gas Service - Open-ended Line |
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)] | 0 |
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)] | 8784 |
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)] | 0 |
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)] | 0 |
Component Type [98.236(q)(2)(i)] | Non-Compressor components, Gas Service - Pressure Relief Valve |
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)] | 0 |
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)] | 8784 |
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)] | 0 |
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)] | 0 |
Component Type [98.236(q)(2)(i)] | Non-Compressor components, Gas Service - Meter or Instrument |
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)] | 0 |
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)] | 8784 |
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)] | 0 |
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)] | 0 |
Component Type [98.236(q)(2)(i)] | Non-Compressor components, Gas Service - Other |
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)] | 0 |
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)] | 8784 |
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)] | 0 |
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)] | 0 |