Source Reporting Form | Facility Overview [98.236(aa)(2-11)] |
Required for Selected Industry Segment | Yes |
Source Reporting Form | Natural Gas Pneumatic Devices [98.236(b)] |
Required for Selected Industry Segment | Yes |
Total Reported CO2 Emissions (mt CO2) | 0.3 |
Total Reported CH4 Emissions (mt CH4) | 8.89 |
Source Reporting Form | Blowdown Vent Stacks [98.236(i)] |
Required for Selected Industry Segment | Yes |
Total Reported CO2 Emissions (mt CO2) | 2.3 |
Total Reported CH4 Emissions (mt CH4) | 78.50 |
Source Reporting Form | Transmission Storage Tanks [98.236(k)] |
Required for Selected Industry Segment | Yes |
Total Reported CO2 Emissions (mt CO2) | 0.0 |
Total Reported CH4 Emissions (mt CH4) | 0.00 |
Source Reporting Form | Flare Stacks [98.236(n)] |
Required for Selected Industry Segment | Yes |
Source Reporting Form | Centrifugal Compressors [98.236(o)] |
Required for Selected Industry Segment | Yes |
Total Reported CO2 Emissions (mt CO2) | 0.0 |
Total Reported CH4 Emissions (mt CH4) | 0.10 |
Source Reporting Form | Reciprocating Compressors [98.236(p)] |
Required for Selected Industry Segment | Yes |
Source Reporting Form | Equipment Leaks Surveys and Population Counts [98.236(q,r)] |
Required for Selected Industry Segment | Yes |
Total Reported CO2 Emissions (mt CO2) | 0.2 |
Total Reported CH4 Emissions (mt CH4) | 5.03 |
Source Reporting Form | Dehydrators [98.236(e)] |
Required for Selected Industry Segment | No |
Source Reporting Form | Atmospheric Storage Tanks [98.236(j)] |
Required for Selected Industry Segment | No |
Source Reporting Form | Onshore Production [98.236(aa)(1)] |
Required for Selected Industry Segment | No |
Source Reporting Form | Natural Gas Driven Pneumatic Pumps [98.236(c)] |
Required for Selected Industry Segment | No |
Source Reporting Form | Acid Gas Removal Units [98.236(d)] |
Required for Selected Industry Segment | No |
Source Reporting Form | Well Venting for Liquids Unloading [98.236(f)] |
Required for Selected Industry Segment | No |
Source Reporting Form | Completions and Workovers with Hydraulic Fracturing [98.236(g)] |
Required for Selected Industry Segment | No |
Source Reporting Form | Completions and Workovers without Hydraulic Fracturing [98.236(h)] |
Required for Selected Industry Segment | No |
Source Reporting Form | Well Testing [98.236(l)] |
Required for Selected Industry Segment | No |
Source Reporting Form | Associated Gas Venting and Flaring [98.236(m)] |
Required for Selected Industry Segment | No |
Source Reporting Form | Offshore Petroleum and Natural Gas Production [98.236(s)] |
Required for Selected Industry Segment | No |
Source Reporting Form | Enhanced Oil Recovery Injection Pumps [98.236(w)] |
Required for Selected Industry Segment | No |
Source Reporting Form | Enhanced Oil Recovery Hydrocarbon Liquids [98.236(x)] |
Required for Selected Industry Segment | No |
Source Reporting Form | Combustion Equipment at Onshore Petroleum and Natural Gas Production Facilities, Onshore Petroleum and Natural Gas Gathering and Boosting Facilities, and Natural gas Distribution Facilities [98.236(z)] |
Required for Selected Industry Segment | No |
Type of Pneumatic Device | High-bleed Pneumatic Devices |
Total Number, Countt [98.236(b)(1)(i)] | 0 |
Total CO2 Emissions (mt CO2) [98.236(b)(3)] | 0.0 |
Total CH4 Emissions (mt CH4) [98.236(b)(4)] | 0.00 |
Estimated average number of hours in the calendar year that the pneumatic devices were operating, Tt (hours) [98.236(b)(2)] | 8784 |
Type of Pneumatic Device | Low-Bleed Pneumatic Devices |
Total Number, Countt [98.236(b)(1)(i)] | 0 |
Total CO2 Emissions (mt CO2) [98.236(b)(3)] | 0.0 |
Total CH4 Emissions (mt CH4) [98.236(b)(4)] | 0.00 |
Estimated average number of hours in the calendar year that the pneumatic devices were operating, Tt (hours) [98.236(b)(2)] | 8784 |
Type of Pneumatic Device | Intermittent Bleed Pneumatic Devices |
Total Number, Countt [98.236(b)(1)(i)] | 23 |
Total CO2 Emissions (mt CO2) [98.236(b)(3)] | 0.3 |
Total CH4 Emissions (mt CH4) [98.236(b)(4)] | 8.89 |
Estimated average number of hours in the calendar year that the pneumatic devices were operating, Tt (hours) [98.236(b)(2)] | 8784 |
Equipment or event type [98.236(i)(1)] [98.236(i)(2)] | All other equipment with a physical volume greater than or equal 50 cubic feet |
Total number of blowdowns for equipment or event type, N [98.236(i)(1)(i)] | 0 |
Annual total CO2 emissions for each equipment or event type (mt CO2) [98.236(i)(1)(ii)] | 0.0 |
Annual total CH4 emissions for each equipment or event type (mt CH4) [98.236(i)(1)(iii)] | 0.00 |
Equipment or event type [98.236(i)(1)] [98.236(i)(2)] | Scrubbers/strainers |
Total number of blowdowns for equipment or event type, N [98.236(i)(1)(i)] | 9 |
Annual total CO2 emissions for each equipment or event type (mt CO2) [98.236(i)(1)(ii)] | 0.2 |
Annual total CH4 emissions for each equipment or event type (mt CH4) [98.236(i)(1)(iii)] | 5.41 |
Equipment or event type [98.236(i)(1)] [98.236(i)(2)] | Compressors |
Total number of blowdowns for equipment or event type, N [98.236(i)(1)(i)] | 16 |
Annual total CO2 emissions for each equipment or event type (mt CO2) [98.236(i)(1)(ii)] | 1.2 |
Annual total CH4 emissions for each equipment or event type (mt CH4) [98.236(i)(1)(iii)] | 41.76 |
Equipment or event type [98.236(i)(1)] [98.236(i)(2)] | Emergency shutdowns |
Total number of blowdowns for equipment or event type, N [98.236(i)(1)(i)] | 0 |
Annual total CO2 emissions for each equipment or event type (mt CO2) [98.236(i)(1)(ii)] | 0.0 |
Annual total CH4 emissions for each equipment or event type (mt CH4) [98.236(i)(1)(iii)] | 0.00 |
Equipment or event type [98.236(i)(1)] [98.236(i)(2)] | Pig launchers and receivers |
Total number of blowdowns for equipment or event type, N [98.236(i)(1)(i)] | 1 |
Annual total CO2 emissions for each equipment or event type (mt CO2) [98.236(i)(1)(ii)] | 0.1 |
Annual total CH4 emissions for each equipment or event type (mt CH4) [98.236(i)(1)(iii)] | 2.32 |
Equipment or event type [98.236(i)(1)] [98.236(i)(2)] | Facility piping |
Total number of blowdowns for equipment or event type, N [98.236(i)(1)(i)] | 6 |
Annual total CO2 emissions for each equipment or event type (mt CO2) [98.236(i)(1)(ii)] | 0.8 |
Annual total CH4 emissions for each equipment or event type (mt CH4) [98.236(i)(1)(iii)] | 29.01 |
Equipment or event type [98.236(i)(1)] [98.236(i)(2)] | Pipeline venting |
Total number of blowdowns for equipment or event type, N [98.236(i)(1)(i)] | 0 |
Annual total CO2 emissions for each equipment or event type (mt CO2) [98.236(i)(1)(ii)] | 0.0 |
Annual total CH4 emissions for each equipment or event type (mt CH4) [98.236(i)(1)(iii)] | 0.00 |
Unique Name or ID number for the transmission storage tank vent stack [98.236(k)(1)(i)] | 318-V-5AT-1 |
Method used to determine if dump valve leakage occurred [98.236(k)(1)(ii)] | Optical gas imaging |
Did dump valve leakage occur? [98.236(k)(1)(iii)] | No |
Was there a flare attached to the transmission storage tank vent? [98.236(k)(1)(iv)] | No |
Did scrubber valve leakage occur while the vent stack was vented directly to the atmosphere? [98.236(k)(2)] | No |
Method used to measure leak rate [98.236(k)(2)(i)] | Acoustic leak detection |
Measured leak rate (standard cubic feet/hour) [98.236(k)(2)(ii)] | 0 |
Duration of time leak is counted as having occurred (vented to atmosphere) (hours) [98.236(k)(2)(iii)] | 8784 |
CO2 emissions from venting gas directly to the atmosphere (mt CO2) [98.236(k)(2)(iv)] | 0.0 |
CH4 emissions from venting gas directly to the atmosphere (mt CH4) [98.236(k)(2)(v)] | 0.00 |
Did scrubber valve leakage occur while the vent stack was vented to a flare? [98.236(k)(3)] | No |
Unique Name or ID number for the transmission storage tank vent stack [98.236(k)(1)(i)] | 318-V-5AT-2 |
Method used to determine if dump valve leakage occurred [98.236(k)(1)(ii)] | Optical gas imaging |
Did dump valve leakage occur? [98.236(k)(1)(iii)] | No |
Was there a flare attached to the transmission storage tank vent? [98.236(k)(1)(iv)] | No |
Did scrubber valve leakage occur while the vent stack was vented directly to the atmosphere? [98.236(k)(2)] | No |
Method used to measure leak rate [98.236(k)(2)(i)] | Acoustic leak detection |
Measured leak rate (standard cubic feet/hour) [98.236(k)(2)(ii)] | 0 |
Duration of time leak is counted as having occurred (vented to atmosphere) (hours) [98.236(k)(2)(iii)] | 8784 |
CO2 emissions from venting gas directly to the atmosphere (mt CO2) [98.236(k)(2)(iv)] | 0.0 |
CH4 emissions from venting gas directly to the atmosphere (mt CH4) [98.236(k)(2)(v)] | 0.00 |
Did scrubber valve leakage occur while the vent stack was vented to a flare? [98.236(k)(3)] | No |
Compressor ID or Unique Name [98.236(o)(1)(i)] | 31801 |
Total time in operating-mode (hours) [98.236(o)(1)(ii)] | 868.5 |
Total time in not-operating-depressurized-mode (hours) [98.236(o)(1)(iii)] | 7916 |
Compressor measured in operating-mode? [98.236(o)(1)(iv)] | No |
Compressor measured in not-operating-depressurized-mode? [98.236(o)(1)(v)] | Yes |
Compressor had blind flanges installed? [98.236(o)(1)(x)] | No |
Seal Type (wet or dry) [98.236(o)(1)(xi)] | Dry |
Power output of compressor driver (hp) [98.236(o)(1)(xiii)] | 26656 |
Compressor had scheduled depressurized shutdown during reporting year? [98.236(o)(1)(xiv)] | Yes |
Compressor ID or Unique Name [98.236(o)(1)(i)] | 31802 |
Total time in operating-mode (hours) [98.236(o)(1)(ii)] | 2727.1 |
Total time in not-operating-depressurized-mode (hours) [98.236(o)(1)(iii)] | 6057 |
Compressor measured in operating-mode? [98.236(o)(1)(iv)] | No |
Compressor measured in not-operating-depressurized-mode? [98.236(o)(1)(v)] | Yes |
Compressor had blind flanges installed? [98.236(o)(1)(x)] | No |
Seal Type (wet or dry) [98.236(o)(1)(xi)] | Dry |
Power output of compressor driver (hp) [98.236(o)(1)(xiii)] | 23970 |
Compressor had scheduled depressurized shutdown during reporting year? [98.236(o)(1)(xiv)] | Yes |
Unique Name or ID for leak or vent (Specify) [98.236(o)(3)(i)(A)] | 31801-Centrif ISOL Val |
Measurement date (mm/dd/yyyy) [98.236(o)(3)(i)(B)] | 2020-10-19 |
Measurement method [98.236(o)(3)(i)(C)] | Acoustic leak detection |
Measured flow rate, MTs,m, MTs,g,avg (standard cubic feet/hour) [98.236(o)(3)(i)(D)] | 0 |
Is the measurement location prior to or after commingling with non-compressor emission sources? [98.236(o)(3)(i)(F)] | Not manifolded |
Compressors in “Not-operating mode” | 31801 |
Unique Name or ID for leak or vent (Specify) [98.236(o)(3)(i)(A)] | 31802-Centrif ISOL Val |
Measurement date (mm/dd/yyyy) [98.236(o)(3)(i)(B)] | 2020-10-19 |
Measurement method [98.236(o)(3)(i)(C)] | Acoustic leak detection |
Measured flow rate, MTs,m, MTs,g,avg (standard cubic feet/hour) [98.236(o)(3)(i)(D)] | 0 |
Is the measurement location prior to or after commingling with non-compressor emission sources? [98.236(o)(3)(i)(F)] | Not manifolded |
Compressors in “Not-operating mode” | 31802 |
Compressor Mode [98.236(o)(3)(ii)(A)] | Operating |
Compressor Source [98.236(o)(3)(ii)(A)] | Wet seal |
Compressor mode-source combination reporter emission factor, EFs,m (standard cubic feet per hour) [98.236(o)(3)(ii)(B)] | 220.637 |
Total number of compressors measured in the compressor mode-source combination in current reporting year and preceding two reporting years [98.236(o)(3)(ii)(C)] | 34 |
Is the reporter emission factor facility-specific or based on all of the reporter's applicable facilities? [98.236(o)(3)(ii)(D)] | All applicable facilities |
Compressor Mode [98.236(o)(3)(ii)(A)] | Operating |
Compressor Source [98.236(o)(3)(ii)(A)] | Blowdown valve |
Compressor mode-source combination reporter emission factor, EFs,m (standard cubic feet per hour) [98.236(o)(3)(ii)(B)] | 1.579 |
Total number of compressors measured in the compressor mode-source combination in current reporting year and preceding two reporting years [98.236(o)(3)(ii)(C)] | 175 |
Is the reporter emission factor facility-specific or based on all of the reporter's applicable facilities? [98.236(o)(3)(ii)(D)] | All applicable facilities |
Compressor Mode [98.236(o)(3)(ii)(A)] | Not-operating |
Compressor Source [98.236(o)(3)(ii)(A)] | Isolation valve |
Compressor mode-source combination reporter emission factor, EFs,m (standard cubic feet per hour) [98.236(o)(3)(ii)(B)] | 21.259 |
Total number of compressors measured in the compressor mode-source combination in current reporting year and preceding two reporting years [98.236(o)(3)(ii)(C)] | 237 |
Is the reporter emission factor facility-specific or based on all of the reporter's applicable facilities? [98.236(o)(3)(ii)(D)] | All applicable facilities |
Unique Name or ID for leak or vent [98.236(o)(2)(i)(C)] | 31801-Centrif Blowdown Val |
Leak or vent for a single compressor source or a manifolded group? [98.236(o)(2)(ii)(A)] [98.236(o)(1)(vi)] | Single |
Where are leak or vent emissions released? [98.236(o)(2)(ii)(A)] [98.236(o)(1)(vii) through (ix)] | Atmosphere |
Was an "as found" measurement conducted on the leak or vent? [98.236(o)(2)(ii)(B)] | No |
Were continuous measurements conducted on the leak or vent? [98.236(o)(2)(ii)(C)] | No |
CO2 emissions vented to atmosphere (mt CO2) [98.236(o)(2)(ii)(D)(1)] | 0.0 |
CH4 emissions vented to atmosphere (mt CH4) [98.236(o)(2)(ii)(D)(2)] | 0.0250 |
Unique Name or ID for leak or vent [98.236(o)(2)(i)(C)] | 31802-Centrif Blowdown Val |
Leak or vent for a single compressor source or a manifolded group? [98.236(o)(2)(ii)(A)] [98.236(o)(1)(vi)] | Single |
Where are leak or vent emissions released? [98.236(o)(2)(ii)(A)] [98.236(o)(1)(vii) through (ix)] | Atmosphere |
Was an "as found" measurement conducted on the leak or vent? [98.236(o)(2)(ii)(B)] | No |
Were continuous measurements conducted on the leak or vent? [98.236(o)(2)(ii)(C)] | No |
CO2 emissions vented to atmosphere (mt CO2) [98.236(o)(2)(ii)(D)(1)] | 0.0 |
CH4 emissions vented to atmosphere (mt CH4) [98.236(o)(2)(ii)(D)(2)] | 0.0785 |
Unique Name or ID for leak or vent [98.236(o)(2)(i)(C)] | 31801-Centrif ISOL Val |
Leak or vent for a single compressor source or a manifolded group? [98.236(o)(2)(ii)(A)] [98.236(o)(1)(vi)] | Single |
Where are leak or vent emissions released? [98.236(o)(2)(ii)(A)] [98.236(o)(1)(vii) through (ix)] | Atmosphere |
Was an "as found" measurement conducted on the leak or vent? [98.236(o)(2)(ii)(B)] | Yes |
Were continuous measurements conducted on the leak or vent? [98.236(o)(2)(ii)(C)] | No |
CO2 emissions vented to atmosphere (mt CO2) [98.236(o)(2)(ii)(D)(1)] | 0.0 |
CH4 emissions vented to atmosphere (mt CH4) [98.236(o)(2)(ii)(D)(2)] | 0.0000 |
Unique Name or ID for leak or vent [98.236(o)(2)(i)(C)] | 31802-Centrif ISOL Val |
Leak or vent for a single compressor source or a manifolded group? [98.236(o)(2)(ii)(A)] [98.236(o)(1)(vi)] | Single |
Where are leak or vent emissions released? [98.236(o)(2)(ii)(A)] [98.236(o)(1)(vii) through (ix)] | Atmosphere |
Was an "as found" measurement conducted on the leak or vent? [98.236(o)(2)(ii)(B)] | Yes |
Were continuous measurements conducted on the leak or vent? [98.236(o)(2)(ii)(C)] | No |
CO2 emissions vented to atmosphere (mt CO2) [98.236(o)(2)(ii)(D)(1)] | 0.0 |
CH4 emissions vented to atmosphere (mt CH4) [98.236(o)(2)(ii)(D)(2)] | 0.0000 |
Component Type [98.236(q)(2)(i)] | Compressor Components, Gas Service - Connector |
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)] | 0 |
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)] | 0 |
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)] | 0.0 |
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)] | 0.00 |
Component Type [98.236(q)(2)(i)] | Compressor Components, Gas Service - Meter |
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)] | 0 |
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)] | 0 |
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)] | 0.0 |
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)] | 0.00 |
Component Type [98.236(q)(2)(i)] | Compressor Components, Gas Service - Open-ended Line |
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)] | 0 |
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)] | 0 |
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)] | 0.0 |
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)] | 0.00 |
Component Type [98.236(q)(2)(i)] | Compressor Components, Gas Service - Pressure Relief Valve |
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)] | 0 |
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)] | 0 |
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)] | 0.0 |
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)] | 0.00 |
Component Type [98.236(q)(2)(i)] | Compressor Components, Gas Service - Valve |
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)] | 1 |
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)] | 8784 |
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)] | 0.1 |
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)] | 2.44 |
Component Type [98.236(q)(2)(i)] | Non-Compressor Components, Gas Service - Connector |
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)] | 0 |
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)] | 0 |
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)] | 0.0 |
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)] | 0.00 |
Component Type [98.236(q)(2)(i)] | Non-Compressor components, Gas Service - Meter |
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)] | 1 |
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)] | 8784 |
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)] | 0.0 |
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)] | 0.48 |
Component Type [98.236(q)(2)(i)] | Non-Compressor Components, Gas Service - Open-ended Line |
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)] | 0 |
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)] | 0 |
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)] | 0.0 |
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)] | 0.00 |
Component Type [98.236(q)(2)(i)] | Non-Compressor Components, Gas Service - Valve |
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)] | 2 |
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)] | 8784 |
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)] | 0.1 |
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)] | 2.11 |
Component Type [98.236(q)(2)(i)] | Non-Compressor components, Gas Service - Pressure Relief Valve |
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)] | 0 |
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)] | 0 |
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)] | 0.0 |
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)] | 0.00 |