Subpart W: Petroleum and Natural Gas Systems
Gas Name | Carbon Dioxide |
Gas Quantity | 372 (Metric Tons) |
Own Result? |
Gas Name | Methane |
Gas Quantity | 97.74 (Metric Tons) |
Own Result? |
Gas Name | Nitrous Oxide |
Gas Quantity | 0.001 (Metric Tons) |
Own Result? |
Industry Segment Number | 9 |
Industry Segment Name | Onshore petroleum and natural gas gathering and boosting [98.230(a)(9)] |
Total Reported CO2 Emissions (mt CO2) | 372.0 |
Total CO2e Emissions (mt CO2e) | 2815.7 |
Total Reported CH4 Emissions (mt CH4) | 97.74 |
Total Reported N2O Emissions (mt N2O) | 0.001 |
Source Reporting Form | Onshore Production [98.236(aa)(1)] |
Required for Selected Industry Segment | No |
Source Reporting Form | Facility Overview [98.236(aa)(2-11)] |
Required for Selected Industry Segment | Yes |
Source Reporting Form | Natural Gas Pneumatic Devices [98.236(b)] |
Required for Selected Industry Segment | Yes |
Total Reported CO2 Emissions (mt CO2) | 0.0 |
Total Reported CH4 Emissions (mt CH4) | 0.00 |
Source Reporting Form | Natural Gas Driven Pneumatic Pumps [98.236(c)] |
Required for Selected Industry Segment | Yes |
Total Reported CO2 Emissions (mt CO2) | 0.0 |
Total Reported CH4 Emissions (mt CH4) | 0.00 |
Source Reporting Form | Acid Gas Removal Units [98.236(d)] |
Required for Selected Industry Segment | Yes |
Total Reported CO2 Emissions (mt CO2) | 0.8 |
Source Reporting Form | Dehydrators [98.236(e)] |
Required for Selected Industry Segment | Yes |
Total Reported CO2 Emissions (mt CO2) | 0.0 |
Total Reported CH4 Emissions (mt CH4) | 0.00 |
Total Reported N2O Emissions (mt N2O) | 0.000 |
Source Reporting Form | Well Venting for Liquids Unloading [98.236(f)] |
Required for Selected Industry Segment | No |
Total Reported CO2 Emissions (mt CO2) | 0.0 |
Total Reported CH4 Emissions (mt CH4) | 0.00 |
Source Reporting Form | Completions and Workovers with Hydraulic Fracturing [98.236(g)] |
Required for Selected Industry Segment | No |
Total Reported CO2 Emissions (mt CO2) | 0.0 |
Total Reported CH4 Emissions (mt CH4) | 0.00 |
Total Reported N2O Emissions (mt N2O) | 0.000 |
Source Reporting Form | Completions and Workovers without Hydraulic Fracturing [98.236(h)] |
Required for Selected Industry Segment | No |
Total Reported CO2 Emissions (mt CO2) | 0.0 |
Total Reported CH4 Emissions (mt CH4) | 0.00 |
Total Reported N2O Emissions (mt N2O) | 0.000 |
Source Reporting Form | Blowdown Vent Stacks [98.236(i)] |
Required for Selected Industry Segment | Yes |
Total Reported CO2 Emissions (mt CO2) | 0.0 |
Total Reported CH4 Emissions (mt CH4) | 0.00 |
Source Reporting Form | Atmospheric Storage Tanks [98.236(j)] |
Required for Selected Industry Segment | Yes |
Total Reported CO2 Emissions (mt CO2) | 0.0 |
Total Reported CH4 Emissions (mt CH4) | 0.00 |
Total Reported N2O Emissions (mt N2O) | 0.000 |
Source Reporting Form | Transmission Storage Tanks [98.236(k)] |
Required for Selected Industry Segment | No |
Total Reported CO2 Emissions (mt CO2) | 0.0 |
Total Reported CH4 Emissions (mt CH4) | 0.00 |
Total Reported N2O Emissions (mt N2O) | 0.000 |
Source Reporting Form | Well Testing [98.236(l)] |
Required for Selected Industry Segment | No |
Total Reported CO2 Emissions (mt CO2) | 0.0 |
Total Reported CH4 Emissions (mt CH4) | 0.00 |
Total Reported N2O Emissions (mt N2O) | 0.000 |
Source Reporting Form | Associated Gas Venting and Flaring [98.236(m)] |
Required for Selected Industry Segment | No |
Total Reported CO2 Emissions (mt CO2) | 0.0 |
Total Reported CH4 Emissions (mt CH4) | 0.00 |
Total Reported N2O Emissions (mt N2O) | 0.000 |
Source Reporting Form | Flare Stacks [98.236(n)] |
Required for Selected Industry Segment | Yes |
Total Reported CO2 Emissions (mt CO2) | 321.7 |
Total Reported CH4 Emissions (mt CH4) | 2.01 |
Total Reported N2O Emissions (mt N2O) | 0.001 |
Source Reporting Form | Centrifugal Compressors [98.236(o)] |
Required for Selected Industry Segment | Yes |
Total Reported CO2 Emissions (mt CO2) | 0.0 |
Total Reported CH4 Emissions (mt CH4) | 0.00 |
Source Reporting Form | Reciprocating Compressors [98.236(p)] |
Required for Selected Industry Segment | Yes |
Total Reported CO2 Emissions (mt CO2) | 0.0 |
Total Reported CH4 Emissions (mt CH4) | 0.00 |
Source Reporting Form | Equipment Leaks Surveys and Population Counts [98.236(q,r)] |
Required for Selected Industry Segment | Yes |
Total Reported CO2 Emissions (mt CO2) | 47.9 |
Total Reported CH4 Emissions (mt CH4) | 95.73 |
Source Reporting Form | Offshore Petroleum and Natural Gas Production [98.236(s)] |
Required for Selected Industry Segment | No |
Total Reported CO2 Emissions (mt CO2) | 0.0 |
Total Reported CH4 Emissions (mt CH4) | 0.00 |
Total Reported N2O Emissions (mt N2O) | 0.000 |
Source Reporting Form | Enhanced Oil Recovery Injection Pumps [98.236(w)] |
Required for Selected Industry Segment | No |
Total Reported CO2 Emissions (mt CO2) | 0.0 |
Source Reporting Form | Enhanced Oil Recovery Hydrocarbon Liquids [98.236(x)] |
Required for Selected Industry Segment | No |
Total Reported CO2 Emissions (mt CO2) | 0.0 |
Source Reporting Form | Combustion Equipment at Onshore Petroleum and Natural Gas Production Facilities, Onshore Petroleum and Natural Gas Gathering and Boosting Facilities, and Natural gas Distribution Facilities [98.236(z)] |
Required for Selected Industry Segment | Yes |
Total Reported CO2 Emissions (mt CO2) | 1.5 |
Total Reported CH4 Emissions (mt CH4) | 0.00 |
Total Reported N2O Emissions (mt N2O) | 0.000 |
Select the basin associated with this facility [98.236(a)(9)] | 740 - Coastal Basins |
Quantity of gas received by the gathering and boosting facility in the calendar year (thousand standard cubic feet) [98.236(aa)(10)(i)] | 549394.3 |
Quantity of gas transported to a natural gas processing facility, a natural gas transmission pipeline, a natural gas distribution pipeline, or another gathering and boosting facility in the calendar year (thousand standard cubic feet) [98.236(aa)(10)(ii)] | 0 |
Quantity of all hydrocarbon liquids received by the gathering and boosting facility in the calendar year (barrels) [98.236(aa)(10)(iii)] | 0 |
Quantity of all hydrocarbon liquids transported to a natural gas processing facility, a natural gas transmission pipeline, a natural gas distribution pipeline, or another gathering and boosting facility in the calendar year (barrels) [98.236(aa)(10)(iv)] | 0 |
mt CO2 | 0.0 |
mt CH4 | 0.00 |
Did the Facility have any continuous high-bleed pneumatic devices subject to reporting under 98.232 [98.236(b)]? | No |
Did the Facility have any intermittent bleed pneumatic devices subject to reporting under 98.232 [98.236(b)]? | No |
Did the Facility have any continuous low-bleed pneumatic devices subject to reporting under 98.232 [98.236(b)]? | No |
Type of Pneumatic Device | High-bleed Pneumatic Devices |
Type of Pneumatic Device | Intermittent Bleed Pneumatic Devices |
Type of Pneumatic Device | Low-Bleed Pneumatic Devices |
mt CO2 | 0.0 |
mt CH4 | 0.00 |
Did the Facility have any natural gas driven pneumatic pumps subject to reporting under 98.232 [98.236(c)]? | No |
Type of Pneumatic Pump | Natural Gas Driven Pneumatic Pumps |
mt CO2 | 0.8 |
Did the Facility have any acid gas removal units that vent directly to the atmosphere, to a flare or engine, or to a sulfur recovery plant subject to reporting under 98.232 [98.236(d)]? | Yes |
Were missing data procedures used for any parameters to calculate GHG emissions? [98.235] | No |
Unit ID or Name [98.236(d)(1)(i)] | SA Sulfatreat |
County and State [98.236(d)(1)(vi)] | MONTEREY, CA |
Total feed rate entering the acid gas removal unit for the year (million cubic feet) [98.236(d)(1)(ii)] | 2.626 |
Calculation Method Used (Select from list) [98.236(d)(1)(iii)] | Calculation Methodology 3 [98.233(d)(3)] |
Are any CO2 emissions from the acid gas removal unit recovered and transferred outside the facility? (Yes / No) [98.236(d)(1)(iv)] | No |
Total CO2 Emissions (mt CO2) [98.236(d)(1)(v)] | 0.7899 |
Unit ID or Name [98.236(d)(1)(i)] | SA Sulfatreat |
Equation Used (W-4A/W-4B) [98.236(d)(2)(ii)(A)] | W-4B |
Annual average fraction of CO2 content of natural gas into the acid gas removal unit, Voli (volumetric fraction) [98.236(d)(2)(ii)(C)] | 0.0958 |
Annual average fraction of CO2 content of natural gas out of the acid gas removal unit, Volo (volumetric fraction) [98.236(d)(2)(ii)(B)] | 0.0937 |
Natural gas flow rate out of the acid gas removal unit, Vout (actual or standard cubic feet) (Eq. W-4B) [98.236(d)(2)(ii)(D)] | 6544000 |
Natural gas flow rate reported on an Actual or Standard basis? [98.236] | Standard |
Temperature used to calculate natural gas flow rate (°F) [98.236] | 83.24 |
Pressure used to calculate natural gas flow rate (psi) [98.236] | 38.27 |
mt CO2 | 0.0 |
mt CH4 | 0.00 |
mt N2O | 0.000 |
Did the facility have any glycol dehydrators with annual average daily natural gas throughputs greater than or equal to 0.4MMscfd subject to reporting under 98.232 [98.236(e)]? | No |
Did the facility have any glycol dehydrators with annual average daily natural gas throughputs less than 0.4MMscfd subject to reporting under 98.232 [98.236(e)]? | No |
Did the facility have any desiccant dehydrators subject to reporting under 98.232 [98.236(e)]? | No |
Emissions vented to flare or regenerator firebox/fire tubes | |
Emissions that were not vented to a flare or regenerator firebox/fire tubes |
Emissions vented to flare or regenerator firebox/fire tubes | |
Emissions that were not vented to a flare or regenerator firebox/fire tubes |
mt CO2 | 0.0 |
mt CH4 | 0.00 |
Did the facility have any blowdown vent stacks subject to reporting under 98.232 [98.236(i)]? | No |
mt CO2 | 0.0 |
mt CH4 | 0.00 |
mt N2O | 0.000 |
Did the facility send hydrocarbon liquids to atmospheric storage tanks that are subject to reporting under 98.232 [98.236(j)]? | No |
Was Calculation Method 1 used to calculate emissions [(98.233(j)(1)]? | No |
Was Calculation Method 2 used to calculate emissions [(98.233(j)(2)]? | No |
Was Calculation Method 3 used to calculate emissions [(98.233(j)(3)]? | No |
If Calculation Method 1 or 2 were used, were any atmospheric tanks observed to have malfunctioning dump valves during the calendar year? | No |
mt CO2 | 321.7 |
mt CH4 | 2.01 |
mt N2O | 0.001 |
Did the facility have flare stacks subject to reporting under 98.232 [98.236(n)]? | Yes |
Were missing data procedures used for any parameters to calculate GHG emissions? [98.235] | No |
Unique Name or ID Number for the Flare Stack [98.236(n)(1)] | SAG Flare - ARB |
Does the flare stack have a continuous flow monitor on gas to the flare? [98.236(n)(2)] | Yes |
Does the flare stack have a continuous gas analyzer on gas to the flare? [98.236(n)(3)] | No |
Were CEMS used to measure CO2 emissions for the flare stack? [98.233(n)(8)] [98.236(n)(12)] | No |
Volume of gas sent to flare, Vs (standard cubic feet) [98.236(n)(4)] | 6544000 |
Flare combustion efficiency (decimal value) [98.236(n)(6)] | 0.98 |
Mole fraction of CH4 in flare feed gas, XCH4 [98.236(n)(7)] | 0.8018 |
Mole fraction of CO2 in flare feed gas, XCO2 [98.236(n)(8)] | 0.0937 |
Fraction of feed gas sent to un-lit flare, Zu [98.236(n)(5)] | 0 |
CO2 emissions (mt CO2) [98.236(n)(9)] | 321.7412 |
CH4 Emissions (mt CH4) (Eq. W-19) [98.236(n)(10)] | 2.0148 |
N2O Emissions (mt N2O) (Eq. W-40) [98.236(n)(11)] | 0.0008 |
mt CO2 | 0.0 |
mt CH4 | 0.00 |
Did the facility have any centrifugal compressors subject to reporting under 98.232 [98.236(o)]? | No |
mt CO2 | 0.0 |
mt CH4 | 0.00 |
Did the facility have any reciprocating compressors subject to reporting under 98.232 [98.236(p)]? | No |
mt CO2 | 47.9 |
mt CH4 | 95.73 |
Did this facility use leak surveys to calculate emissions from equipment leaks in accordance with 98.232 [per 98.236(q)]? | No |
Did this facility use population counts to calculate emissions from equipment leaks in accordance with 98.232 [per 98.236(r)]? | Yes |
Did the facility elect to comply with 98.236(q) according to 98.233(q)(1)(iv) for any components at the facility [per 98.236(q)(1)(iv)]? | No |
Were missing data procedures used for any parameters to calculate GHG emissions? [98.235] | No |
Component count calculation method for all emission source types in Table R.1 other than gathering pipelines [98.236(r)(3)(i)] | Component Count Method 1 |
Emission Source Type (Eq. W-32A) [98.232(c)(21)] [98.233(r)] | Gas Service - Valves |
Geographic Location (according to Table W-1D) [98.236(r)(1)(i)] | Western U.S. |
Total number of emission source type, Counte (for gathering pipelines, this value is the number of miles of pipeline per material type) [98.236(r)(1)(ii)] | 1202 |
Average estimated time that the emission source type was operational in the calendar year, Te (hours) [98.236(r)(1)(iii)] | 8784 |
CO2 Emissions (mt CO2) [98.236(r)(1)(iv)] | 9.2464 |
CH4 Emissions (mt CH4) [98.236(r)(1)(v)] | 18.47 |
Emission Source Type (Eq. W-32A) [98.232(c)(21)] [98.233(r)] | Gas Service - Connectors |
Geographic Location (according to Table W-1D) [98.236(r)(1)(i)] | Western U.S. |
Total number of emission source type, Counte (for gathering pipelines, this value is the number of miles of pipeline per material type) [98.236(r)(1)(ii)] | 3687 |
Average estimated time that the emission source type was operational in the calendar year, Te (hours) [98.236(r)(1)(iii)] | 8784 |
CO2 Emissions (mt CO2) [98.236(r)(1)(iv)] | 3.9848 |
CH4 Emissions (mt CH4) [98.236(r)(1)(v)] | 7.9598 |
Emission Source Type (Eq. W-32A) [98.232(c)(21)] [98.233(r)] | Gas Service - Open ended lines |
Geographic Location (according to Table W-1D) [98.236(r)(1)(i)] | Western U.S. |
Total number of emission source type, Counte (for gathering pipelines, this value is the number of miles of pipeline per material type) [98.236(r)(1)(ii)] | 185 |
Average estimated time that the emission source type was operational in the calendar year, Te (hours) [98.236(r)(1)(iii)] | 8784 |
CO2 Emissions (mt CO2) [98.236(r)(1)(iv)] | 0.3646 |
CH4 Emissions (mt CH4) [98.236(r)(1)(v)] | 0.7283 |
Emission Source Type (Eq. W-32A) [98.232(c)(21)] [98.233(r)] | Gas Service - Pressure relief valves |
Geographic Location (according to Table W-1D) [98.236(r)(1)(i)] | Western U.S. |
Total number of emission source type, Counte (for gathering pipelines, this value is the number of miles of pipeline per material type) [98.236(r)(1)(ii)] | 71 |
Average estimated time that the emission source type was operational in the calendar year, Te (hours) [98.236(r)(1)(iii)] | 8784 |
CO2 Emissions (mt CO2) [98.236(r)(1)(iv)] | 0.8712 |
CH4 Emissions (mt CH4) [98.236(r)(1)(v)] | 1.7402 |
Emission Source Type (Eq. W-32A) [98.232(c)(21)] [98.233(r)] | Gathering pipelines - Protected steel gathering pipeline |
Geographic Location (according to Table W-1D) [98.236(r)(1)(i)] | Western U.S. |
Total number of emission source type, Counte (for gathering pipelines, this value is the number of miles of pipeline per material type) [98.236(r)(1)(ii)] | 0 |
Average estimated time that the emission source type was operational in the calendar year, Te (hours) [98.236(r)(1)(iii)] | 0 |
CO2 Emissions (mt CO2) [98.236(r)(1)(iv)] | 0 |
CH4 Emissions (mt CH4) [98.236(r)(1)(v)] | 0 |
Emission Source Type (Eq. W-32A) [98.232(c)(21)] [98.233(r)] | Gathering pipelines - Unprotected steel gathering pipeline |
Geographic Location (according to Table W-1D) [98.236(r)(1)(i)] | Western U.S. |
Total number of emission source type, Counte (for gathering pipelines, this value is the number of miles of pipeline per material type) [98.236(r)(1)(ii)] | 31.72 |
Average estimated time that the emission source type was operational in the calendar year, Te (hours) [98.236(r)(1)(iii)] | 8784 |
CO2 Emissions (mt CO2) [98.236(r)(1)(iv)] | 33.4551 |
CH4 Emissions (mt CH4) [98.236(r)(1)(v)] | 66.8278 |
Emission Source Type (Eq. W-32A) [98.232(c)(21)] [98.233(r)] | Gathering pipelines - Plastic/composite gathering pipeline |
Geographic Location (according to Table W-1D) [98.236(r)(1)(i)] | Western U.S. |
Total number of emission source type, Counte (for gathering pipelines, this value is the number of miles of pipeline per material type) [98.236(r)(1)(ii)] | 0 |
Average estimated time that the emission source type was operational in the calendar year, Te (hours) [98.236(r)(1)(iii)] | 0 |
CO2 Emissions (mt CO2) [98.236(r)(1)(iv)] | 0 |
CH4 Emissions (mt CH4) [98.236(r)(1)(v)] | 0 |
Emission Source Type (Eq. W-32A) [98.232(c)(21)] [98.233(r)] | Gathering pipelines - Cast iron gathering pipeline |
Geographic Location (according to Table W-1D) [98.236(r)(1)(i)] | Western U.S. |
Total number of emission source type, Counte (for gathering pipelines, this value is the number of miles of pipeline per material type) [98.236(r)(1)(ii)] | 0 |
Average estimated time that the emission source type was operational in the calendar year, Te (hours) [98.236(r)(1)(iii)] | 0 |
CO2 Emissions (mt CO2) [98.236(r)(1)(iv)] | 0 |
CH4 Emissions (mt CH4) [98.236(r)(1)(v)] | 0 |
Major Equipment Type [98.236(r)(3)(ii)] | Wellhead |
Equipment type present at facility? [98.236(r)(3)(ii)(A)] | No |
Major Equipment Type [98.236(r)(3)(ii)] | Separators |
Equipment type present at facility? [98.236(r)(3)(ii)(A)] | Yes |
Count of Major Equipment Type in Western US [98.236(r)(3)(ii)(B)] | 29 |
Major Equipment Type [98.236(r)(3)(ii)] | Meters/piping |
Equipment type present at facility? [98.236(r)(3)(ii)(A)] | Yes |
Count of Major Equipment Type in Western US [98.236(r)(3)(ii)(B)] | 5 |
Major Equipment Type [98.236(r)(3)(ii)] | Compressors |
Equipment type present at facility? [98.236(r)(3)(ii)(A)] | Yes |
Count of Major Equipment Type in Western US [98.236(r)(3)(ii)(B)] | 2 |
Major Equipment Type [98.236(r)(3)(ii)] | In-line heaters |
Equipment type present at facility? [98.236(r)(3)(ii)(A)] | No |
Major Equipment Type [98.236(r)(3)(ii)] | Dehydrators |
Equipment type present at facility? [98.236(r)(3)(ii)(A)] | No |
mt CO2 | 1.5 |
mt CH4 | 0.00 |
mt N2O | 0.000 |
Did the Facility have combustion units subject to reporting under 98.232? | Yes |
Were missing data procedures used for any parameters to calculate GHG emissions? [98.235] | No |
Are there external fuel combustion units with a rated heat capacity less than or equal to 5 mmBtu/hr? [98.236(z)(1)(i)] | No |
Are there internal fuel combustion units that are not compressor-drivers, with a rated heat capacity less than or equal to 1 mmBtu/hr? [98.236(z)(1)(i)] | Yes |
Total number of combustion units meeting 98.236(z)(1) descriptions | 26 |
Are there external fuel combustion units with a rated heat capacity greater than 5 mmBtu/hr? [98.236(z)(2)(i)] | No |
Are there internal fuel combustion units that are not compressor-drivers, with a rated heat capacity greater than 1 mmBtu/hr? [98.236(z)(2)(i)] | Yes |
Are there Internal fuel combustion units of any heat capacity that are compressor-drivers? [98.236(z)(2)(i)] | No |
Type of combustion unit [98.236(z)(2)(i)] | Internal fuel combustion units that are not compressor-drivers, with a rated heat capacity greater than 1 mmBtu/hr |
Type of fuel combusted [98.236(z)(2)(ii)] | Petroleum products: distillate fuel oil No. 2 |
Quantity of fuel combusted in calendar year [98.236(z)(2)(iii)] | 149.8 |
Unit of measure [98.236(z)(2)(iii) | gallons |
CO2 Emissions (mt CO2) [98.236(z)(2)(iv)] | 1.5289 |
CH4 Emissions (mt CH4) [98.236(z)(2)(v)] | 0.00006 |
N2O Emissions (mt N2O) [98.236(z)(2)(vi)] | 0.00001 |