Facility Name:50 Buttes Gas Plant
Facility Identifier:
Facility Reporting Year:2020
Facility Location:
Address: 3669 South Hwy 50
City: Gillette
State: WY
Postal Code: 82716

Facility Site Details:
CO2 equivalent emissions from facility subparts C-II, SS, and TT (metric tons):72,243.5
CO2 equivalent emissions from supplier subparts LL-QQ (metric tons):
Biogenic CO2 emissions from facility subparts C-II, SS, and TT (metric tons):0
Cogeneration Unit Emissions Indicator:N
GHG Report Start Date:2020-01-01
GHG Report End Date:2020-12-31
Description of Changes to Calculation Methodology:
Plant Code Indicator:N
Primary NAICS Code:213112
Second Primary NAICS Code:

Parent Company Details:
Parent Company Name:MERITAGE MIDSTREAM SERVICES II LLC
Address:1331 seventeenth Street suite 1100, Denver,  CO 80202
Percent Ownership Interest:100

Subpart C: General Stationary Fuel Combustion

Gas Information Details

Gas NameCarbon Dioxide
Gas Quantity68,023 (Metric Tons)
Own Result?

Gas NameBiogenic Carbon dioxide
Gas Quantity0 (Metric Tons)
Own Result?

Gas NameMethane
Gas Quantity1.29 (Metric Tons)
Own Result?

Gas NameNitrous Oxide
Gas Quantity0.129 (Metric Tons)
Own Result?

Unit Details:
Unit Name : GP-50Buttes
Unit Type : OCS (Other combustion source)
Unit Description :
Other Unit Name :
Small Unit Aggregation Details:
Use Ivt Indicator: N
Highest Maximum Rated Heat Input Capacity: 15.38
Cumulative Maximum Rated Heat Input Capacity: 225.96

Emission Details:
Annual CO2 mass emissions from sorbent: 0 (Metric Tons)
Annual Biogenic CO2 Emissions: 0 (metric tons)
Annual Fossil fuel based CO2 Emissions: 67893.5 (metric tons)

Tier Fuel Details:
Fuel : Natural Gas (Weighted U.S. Average)
Tier Name : Tier 1 (Equation C-1)
Tier Methodology Start Date : 2020-01-01
Tier Methodology End Date : 2020-12-31

Fuel Emission Details :
Total CO2 emissionsTotal CH4 emissionsTotal N2O emissionsTotal CH4 emissions CO2eTotal N2O emissions CO2e
67893.5 (Metric Tons) 1.28 (Metric Tons) 0.128 (Metric Tons) 32 (Metric Tons) 38.1 (Metric Tons)

Equation C1/C8 Inputs :
Fuel Quantity : 1247134444.35 (scf/year)

Unit Name : GP-50Buttes-Diesel
Unit Type : OCS (Other combustion source)
Unit Description :
Other Unit Name :
Small Unit Aggregation Details:
Use Ivt Indicator: N
Highest Maximum Rated Heat Input Capacity: 0.80
Cumulative Maximum Rated Heat Input Capacity:

Emission Details:
Annual CO2 mass emissions from sorbent: 0 (Metric Tons)
Annual Biogenic CO2 Emissions: 0 (metric tons)
Annual Fossil fuel based CO2 Emissions: 129.5 (metric tons)

Tier Fuel Details:
Fuel : Distillate Fuel Oil No. 2
Tier Name : Tier 1 (Equation C-1)
Tier Methodology Start Date : 2020-01-01
Tier Methodology End Date : 2020-12-31

Fuel Emission Details :
Total CO2 emissionsTotal CH4 emissionsTotal N2O emissionsTotal CH4 emissions CO2eTotal N2O emissions CO2e
129.5 (Metric Tons) 0.01 (Metric Tons) 0.001 (Metric Tons) 0.1 (Metric Tons) 0.3 (Metric Tons)

Equation C1/C8 Inputs :
Fuel Quantity : 12690.40 (gallons/year)


Subpart W: Petroleum and Natural Gas Systems

Gas Information Details

Gas NameCarbon Dioxide
Gas Quantity2,316.7 (Metric Tons)
Own Result?

Gas NameMethane
Gas Quantity73.29 (Metric Tons)
Own Result?

Gas NameNitrous Oxide
Gas Quantity0.003 (Metric Tons)
Own Result?


SubpartWSummaryDetails:
Industry Segment Number3
Industry Segment NameOnshore natural gas processing [98.230(a)(3)]
Total Reported CO2 Emissions (mt CO2)2316.7
Total CO2e Emissions (mt CO2e)4149.7
Total Reported CH4 Emissions (mt CH4)73.29
Total Reported N2O Emissions (mt N2O)0.003


SubpartWSourceReportingFormRowDetails:
Source Reporting FormOnshore Production [98.236(aa)(1)]
Required for Selected Industry SegmentNo
Source Reporting FormFacility Overview [98.236(aa)(2-11)]
Required for Selected Industry SegmentYes
Source Reporting FormNatural Gas Pneumatic Devices [98.236(b)]
Required for Selected Industry SegmentNo
Total Reported CO2 Emissions (mt CO2)0.0
Total Reported CH4 Emissions (mt CH4)0.00
Source Reporting FormNatural Gas Driven Pneumatic Pumps [98.236(c)]
Required for Selected Industry SegmentNo
Total Reported CO2 Emissions (mt CO2)0.0
Total Reported CH4 Emissions (mt CH4)0.00
Source Reporting FormAcid Gas Removal Units [98.236(d)]
Required for Selected Industry SegmentYes
Total Reported CO2 Emissions (mt CO2)0.0
Source Reporting FormDehydrators [98.236(e)]
Required for Selected Industry SegmentYes
Total Reported CO2 Emissions (mt CO2)72.9
Total Reported CH4 Emissions (mt CH4)0.20
Total Reported N2O Emissions (mt N2O)0.000
Source Reporting FormWell Venting for Liquids Unloading [98.236(f)]
Required for Selected Industry SegmentNo
Total Reported CO2 Emissions (mt CO2)0.0
Total Reported CH4 Emissions (mt CH4)0.00
Source Reporting FormCompletions and Workovers with Hydraulic Fracturing [98.236(g)]
Required for Selected Industry SegmentNo
Total Reported CO2 Emissions (mt CO2)0.0
Total Reported CH4 Emissions (mt CH4)0.00
Total Reported N2O Emissions (mt N2O)0.000
Source Reporting FormCompletions and Workovers without Hydraulic Fracturing [98.236(h)]
Required for Selected Industry SegmentNo
Total Reported CO2 Emissions (mt CO2)0.0
Total Reported CH4 Emissions (mt CH4)0.00
Total Reported N2O Emissions (mt N2O)0.000
Source Reporting FormBlowdown Vent Stacks [98.236(i)]
Required for Selected Industry SegmentYes
Total Reported CO2 Emissions (mt CO2)0.3
Total Reported CH4 Emissions (mt CH4)4.71
Source Reporting FormAtmospheric Storage Tanks [98.236(j)]
Required for Selected Industry SegmentNo
Total Reported CO2 Emissions (mt CO2)0.0
Total Reported CH4 Emissions (mt CH4)0.00
Total Reported N2O Emissions (mt N2O)0.000
Source Reporting FormTransmission Storage Tanks [98.236(k)]
Required for Selected Industry SegmentNo
Total Reported CO2 Emissions (mt CO2)0.0
Total Reported CH4 Emissions (mt CH4)0.00
Total Reported N2O Emissions (mt N2O)0.000
Source Reporting FormWell Testing [98.236(l)]
Required for Selected Industry SegmentNo
Total Reported CO2 Emissions (mt CO2)0.0
Total Reported CH4 Emissions (mt CH4)0.00
Total Reported N2O Emissions (mt N2O)0.000
Source Reporting FormAssociated Gas Venting and Flaring [98.236(m)]
Required for Selected Industry SegmentNo
Total Reported CO2 Emissions (mt CO2)0.0
Total Reported CH4 Emissions (mt CH4)0.00
Total Reported N2O Emissions (mt N2O)0.000
Source Reporting FormFlare Stacks [98.236(n)]
Required for Selected Industry SegmentYes
Total Reported CO2 Emissions (mt CO2)2236.2
Total Reported CH4 Emissions (mt CH4)7.96
Total Reported N2O Emissions (mt N2O)0.003
Source Reporting FormCentrifugal Compressors [98.236(o)]
Required for Selected Industry SegmentYes
Total Reported CO2 Emissions (mt CO2)0.0
Total Reported CH4 Emissions (mt CH4)0.00
Source Reporting FormReciprocating Compressors [98.236(p)]
Required for Selected Industry SegmentYes
Total Reported CO2 Emissions (mt CO2)5.6
Total Reported CH4 Emissions (mt CH4)28.94
Source Reporting FormEquipment Leaks Surveys and Population Counts [98.236(q,r)]
Required for Selected Industry SegmentYes
Total Reported CO2 Emissions (mt CO2)1.8
Total Reported CH4 Emissions (mt CH4)31.48
Source Reporting FormOffshore Petroleum and Natural Gas Production [98.236(s)]
Required for Selected Industry SegmentNo
Total Reported CO2 Emissions (mt CO2)0.0
Total Reported CH4 Emissions (mt CH4)0.00
Total Reported N2O Emissions (mt N2O)0.000
Source Reporting FormEnhanced Oil Recovery Injection Pumps [98.236(w)]
Required for Selected Industry SegmentNo
Total Reported CO2 Emissions (mt CO2)0.0
Source Reporting FormEnhanced Oil Recovery Hydrocarbon Liquids [98.236(x)]
Required for Selected Industry SegmentNo
Total Reported CO2 Emissions (mt CO2)0.0
Source Reporting FormCombustion Equipment at Onshore Petroleum and Natural Gas Production Facilities, Onshore Petroleum and Natural Gas Gathering and Boosting Facilities, and Natural gas Distribution Facilities [98.236(z)]
Required for Selected Industry SegmentNo
Total Reported CO2 Emissions (mt CO2)0.0
Total Reported CH4 Emissions (mt CH4)0.00
Total Reported N2O Emissions (mt N2O)0.000


FacilityOverviewDetails:


FacilityOverviewNaturalGasProcessingRowDetails:
Average mole fraction of CH4 in natural gas received [98.236(aa)(3)(v)]0.75777
Average mole fraction of CO2 in natural gas received [98.236(aa)(3)(vi)]0.01645
Does the facility fractionate NGLs? [98.236(aa)(3)(vii)]No


AcidGasRemovalUnitsDetails:
mt CO20.0
Did the Facility have any acid gas removal units that vent directly to the atmosphere, to a flare or engine, or to a sulfur recovery plant subject to reporting under 98.232 [98.236(d)]?No


DehydratorsDetails:
mt CO272.9
mt CH40.20
mt N2O0.000
Did the facility have any glycol dehydrators with annual average daily natural gas throughputs greater than or equal to 0.4MMscfd subject to reporting under 98.232 [98.236(e)]?Yes
Did the facility have any glycol dehydrators with annual average daily natural gas throughputs less than 0.4MMscfd subject to reporting under 98.232 [98.236(e)]?No
Did the facility have any desiccant dehydrators subject to reporting under 98.232 [98.236(e)]?No
Were missing data procedures used for any parameters to calculate GHG emissions? [98.235]No


SmallGlycolDehydrators:
Emissions vented to flare or regenerator firebox/fire tubes
Emissions that were not vented to a flare or regenerator firebox/fire tubes


DessicantDehydrators:
Emissions vented to flare or regenerator firebox/fire tubes
Emissions that were not vented to a flare or regenerator firebox/fire tubes


GlycolDehydratorsMoreThanSpecifiedValueRowDetails:
Unit ID or Name [98.236(e)(1)(i)]DHY001
Glycol dehydrator feed natural gas flow rate determined by engineering estimate based on best available data (MMscfd) [98.236(e)(1)(ii)]46.8844101
Dehydrator feed natural gas water content (pounds per MMscf) [98.236(e)(1)(iii)]19.46
Dehydrator outlet natural gas water content (pounds per MMscf) [98.236(e)(1)(iv)]2.185
Glycol dehydrator absorbent circulation pump type [98.236(e)(1)(v)]Electric
Dehydrator absorbent circulation rate (gallons per minute) [98.236(e)(1)(vi)]4.2221311
Report type of absorbent used [98.236(e)(1)(vii)]Ethylene glycol (EG)
Report whether stripper gas is used in glycol dehydrator [98.236(e)(1)(viii)]No
Report whether a flash tank separator is used in glycol dehydrator [98.236(e)(1)(ix)]Yes
Total time the glycol dehydrator is operating (hours) [98.236(e)(1)(x)]8135
Temperature of the wet natural gas (°F) [98.236(e)(1)(xi)]52.573
Pressure of the wet natural gas (psig) [98.236(e)(1)(xii)]543
Concentration of CO2 in wet natural gas (mole fraction) [98.236(e)(1)(xiv)]0.0140556
Concentration of CH4 in wet natural gas (mole fraction) [98.236(e)(1)(xiii)]0.743465
Were any dehydrator emissions vented to a vapor recovery device? [98.236(e)(1)(xv)]No
Were any dehydrator emissions vented to a flare or regenerator firebox/fire tubes? [98.236(e)(1)(xvi)]Yes
CO2 Emissions from Flares or Regenerators (mt CO2) [98.236(e)(1)(xvi)(A)]38.910722
CH4 Emissions from Flares or Regenerators (mt CH4) [98.236(e)(1)(xvi)(B)]0.1105086
N2O Emissions from Flares or Regenerators (mt N2O) [98.236(e)(1)(xvi)(C)]0.0000498
Were any dehydrator emissions vented to the atmosphere without being routed to a flare or regenerator firebox/fire tubes? [98.236(e)(1)(xvii)]No
Unit ID or Name [98.236(e)(1)(i)]DHY002
Glycol dehydrator feed natural gas flow rate determined by engineering estimate based on best available data (MMscfd) [98.236(e)(1)(ii)]24.6838191
Dehydrator feed natural gas water content (pounds per MMscf) [98.236(e)(1)(iii)]19.511
Dehydrator outlet natural gas water content (pounds per MMscf) [98.236(e)(1)(iv)]2.2211
Glycol dehydrator absorbent circulation pump type [98.236(e)(1)(v)]Electric
Dehydrator absorbent circulation rate (gallons per minute) [98.236(e)(1)(vi)]4.8642077
Report type of absorbent used [98.236(e)(1)(vii)]Ethylene glycol (EG)
Report whether stripper gas is used in glycol dehydrator [98.236(e)(1)(viii)]No
Report whether a flash tank separator is used in glycol dehydrator [98.236(e)(1)(ix)]Yes
Total time the glycol dehydrator is operating (hours) [98.236(e)(1)(x)]6113.75
Temperature of the wet natural gas (°F) [98.236(e)(1)(xi)]52.558
Pressure of the wet natural gas (psig) [98.236(e)(1)(xii)]543
Concentration of CO2 in wet natural gas (mole fraction) [98.236(e)(1)(xiv)]0.0140547
Concentration of CH4 in wet natural gas (mole fraction) [98.236(e)(1)(xiii)]0.7434201
Were any dehydrator emissions vented to a vapor recovery device? [98.236(e)(1)(xv)]No
Were any dehydrator emissions vented to a flare or regenerator firebox/fire tubes? [98.236(e)(1)(xvi)]Yes
CO2 Emissions from Flares or Regenerators (mt CO2) [98.236(e)(1)(xvi)(A)]33.9716987
CH4 Emissions from Flares or Regenerators (mt CH4) [98.236(e)(1)(xvi)(B)]0.0928517
N2O Emissions from Flares or Regenerators (mt N2O) [98.236(e)(1)(xvi)(C)]0.0000438
Were any dehydrator emissions vented to the atmosphere without being routed to a flare or regenerator firebox/fire tubes? [98.236(e)(1)(xvii)]No


BlowdownVentStacksDetails:
mt CO20.3
mt CH44.71
Did the facility have any blowdown vent stacks subject to reporting under 98.232 [98.236(i)]?Yes
Were missing data procedures used for any parameters to calculate GHG emissions? [98.235]No
How were emissions determined? [98.236(i)]Calculated by equipment or event type


BlowdownEquipmentOrEventEmissionsRowDetails:
Equipment or event type [98.236(i)(1)] [98.236(i)(2)]Compressors
Total number of blowdowns for equipment or event type, N [98.236(i)(1)(i)]64
Annual total CO2 emissions for each equipment or event type (mt CO2) [98.236(i)(1)(ii)]0.3214475
Annual total CH4 emissions for each equipment or event type (mt CH4) [98.236(i)(1)(iii)]4.7087185


FlareStacksDetails:
mt CO22236.2
mt CH47.96
mt N2O0.003
Did the facility have flare stacks subject to reporting under 98.232 [98.236(n)]?Yes
Were missing data procedures used for any parameters to calculate GHG emissions? [98.235]No


UniqueFlareStacksRowDetails:
Unique Name or ID Number for the Flare Stack [98.236(n)(1)]50 Buttes Emergency Flare - FLR001
Does the flare stack have a continuous flow monitor on gas to the flare? [98.236(n)(2)]No
Does the flare stack have a continuous gas analyzer on gas to the flare? [98.236(n)(3)]No
Were CEMS used to measure CO2 emissions for the flare stack? [98.233(n)(8)] [98.236(n)(12)]No
Volume of gas sent to flare, Vs (standard cubic feet) [98.236(n)(4)]11449090
Flare combustion efficiency (decimal value) [98.236(n)(6)]0.98
Mole fraction of CH4 in flare feed gas, XCH4 [98.236(n)(7)]0.7829398
Mole fraction of CO2 in flare feed gas, XCO2 [98.236(n)(8)]0.0147596
Fraction of feed gas sent to un-lit flare, Zu [98.236(n)(5)]0
CO2 emissions (mt CO2) [98.236(n)(9)]740.6763263
CH4 Emissions (mt CH4) (Eq. W-19) [98.236(n)(10)]3.4421562
N2O Emissions (mt N2O) (Eq. W-40) [98.236(n)(11)]0.0013625
Unique Name or ID Number for the Flare Stack [98.236(n)(1)]50 Buttes Thermal Oxidizer - FLR002
Does the flare stack have a continuous flow monitor on gas to the flare? [98.236(n)(2)]No
Does the flare stack have a continuous gas analyzer on gas to the flare? [98.236(n)(3)]No
Were CEMS used to measure CO2 emissions for the flare stack? [98.233(n)(8)] [98.236(n)(12)]No
Volume of gas sent to flare, Vs (standard cubic feet) [98.236(n)(4)]1473622.2946481
Flare combustion efficiency (decimal value) [98.236(n)(6)]0.98
Mole fraction of CH4 in flare feed gas, XCH4 [98.236(n)(7)]0.7939996
Mole fraction of CO2 in flare feed gas, XCO2 [98.236(n)(8)]0.0149568
Fraction of feed gas sent to un-lit flare, Zu [98.236(n)(5)]0
CO2 emissions (mt CO2) [98.236(n)(9)]93.1265927
CH4 Emissions (mt CH4) (Eq. W-19) [98.236(n)(10)]0.4493013
N2O Emissions (mt N2O) (Eq. W-40) [98.236(n)(11)]0.000095
Unique Name or ID Number for the Flare Stack [98.236(n)(1)]50 Buttes Combustor - FLR004
Does the flare stack have a continuous flow monitor on gas to the flare? [98.236(n)(2)]No
Does the flare stack have a continuous gas analyzer on gas to the flare? [98.236(n)(3)]No
Were CEMS used to measure CO2 emissions for the flare stack? [98.233(n)(8)] [98.236(n)(12)]No
Volume of gas sent to flare, Vs (standard cubic feet) [98.236(n)(4)]1532566.3159509
Flare combustion efficiency (decimal value) [98.236(n)(6)]0.98
Mole fraction of CH4 in flare feed gas, XCH4 [98.236(n)(7)]0.2523411
Mole fraction of CO2 in flare feed gas, XCO2 [98.236(n)(8)]0.0047534
Fraction of feed gas sent to un-lit flare, Zu [98.236(n)(5)]0
CO2 emissions (mt CO2) [98.236(n)(9)]297.3430357
CH4 Emissions (mt CH4) (Eq. W-19) [98.236(n)(10)]0.1485041
N2O Emissions (mt N2O) (Eq. W-40) [98.236(n)(11)]0.0004905
Unique Name or ID Number for the Flare Stack [98.236(n)(1)]50 Buttes Process Flare - FLR006
Does the flare stack have a continuous flow monitor on gas to the flare? [98.236(n)(2)]No
Does the flare stack have a continuous gas analyzer on gas to the flare? [98.236(n)(3)]No
Were CEMS used to measure CO2 emissions for the flare stack? [98.233(n)(8)] [98.236(n)(12)]No
Volume of gas sent to flare, Vs (standard cubic feet) [98.236(n)(4)]11333325
Flare combustion efficiency (decimal value) [98.236(n)(6)]0.98
Mole fraction of CH4 in flare feed gas, XCH4 [98.236(n)(7)]0.7829398
Mole fraction of CO2 in flare feed gas, XCO2 [98.236(n)(8)]0.0147596
Fraction of feed gas sent to un-lit flare, Zu [98.236(n)(5)]0
CO2 emissions (mt CO2) [98.236(n)(9)]732.7191667
CH4 Emissions (mt CH4) (Eq. W-19) [98.236(n)(10)]3.4073516
N2O Emissions (mt N2O) (Eq. W-40) [98.236(n)(11)]0.0000834
Unique Name or ID Number for the Flare Stack [98.236(n)(1)]50 Buttes Thermal Oxidizer - FLR007
Does the flare stack have a continuous flow monitor on gas to the flare? [98.236(n)(2)]No
Does the flare stack have a continuous gas analyzer on gas to the flare? [98.236(n)(3)]No
Were CEMS used to measure CO2 emissions for the flare stack? [98.233(n)(8)] [98.236(n)(12)]No
Volume of gas sent to flare, Vs (standard cubic feet) [98.236(n)(4)]1186434.0116049
Flare combustion efficiency (decimal value) [98.236(n)(6)]0.98
Mole fraction of CH4 in flare feed gas, XCH4 [98.236(n)(7)]0.7939996
Mole fraction of CO2 in flare feed gas, XCO2 [98.236(n)(8)]0.0149568
Fraction of feed gas sent to un-lit flare, Zu [98.236(n)(5)]0
CO2 emissions (mt CO2) [98.236(n)(9)]74.970499
CH4 Emissions (mt CH4) (Eq. W-19) [98.236(n)(10)]0.3617388
N2O Emissions (mt N2O) (Eq. W-40) [98.236(n)(11)]0.0000714
Unique Name or ID Number for the Flare Stack [98.236(n)(1)]50 Buttes Combustor - FLR005
Does the flare stack have a continuous flow monitor on gas to the flare? [98.236(n)(2)]No
Does the flare stack have a continuous gas analyzer on gas to the flare? [98.236(n)(3)]No
Were CEMS used to measure CO2 emissions for the flare stack? [98.233(n)(8)] [98.236(n)(12)]No
Volume of gas sent to flare, Vs (standard cubic feet) [98.236(n)(4)]1532566.3159509
Flare combustion efficiency (decimal value) [98.236(n)(6)]0.98
Mole fraction of CH4 in flare feed gas, XCH4 [98.236(n)(7)]0.2523411
Mole fraction of CO2 in flare feed gas, XCO2 [98.236(n)(8)]0.0047534
Fraction of feed gas sent to un-lit flare, Zu [98.236(n)(5)]0
CO2 emissions (mt CO2) [98.236(n)(9)]297.3430357
CH4 Emissions (mt CH4) (Eq. W-19) [98.236(n)(10)]0.1485041
N2O Emissions (mt N2O) (Eq. W-40) [98.236(n)(11)]0.0004905


CentrifugalCompressorsDetails:
mt CO20.0
mt CH40.00
Did the facility have any centrifugal compressors subject to reporting under 98.232 [98.236(o)]?No


ReciprocatingCompressorsDetails:
mt CO25.6
mt CH428.94
Did the facility have any reciprocating compressors subject to reporting under 98.232 [98.236(p)]?Yes
Were missing data procedures used for any parameters to calculate GHG emissions? [98.235]No


ReciprocatingCompressorsActivityDataRowDetails:
Unique name or ID for reciprocating compressor [98.236(p)(1)(i)]FB-A
Total time in operating-mode (hours) [98.236(p)(1)(ii)]5190
Total time in standby-pressurized-mode (hours) [98.236(p)(1)(iii)]3587
Total time in not-operating-depressurized-mode (hours) [98.236(p)(1)(iv)]7
Compressor measured in operating-mode? [98.236(p)(1)(v)]Yes
Compressor measured in standby-pressurized-mode? [98.236(p)(1)(vi)]No
Compressor measured in not-operating-depressurized-mode? [98.236(p)(1)(vii)]No
Compressor had blind flanges installed? [98.236(p)(1)(xii)]No
Power output of compressor driver (hp) [98.236(p)(1)(xiii)]1340
Compressor had scheduled depressurized shutdown during reporting year? [98.236(p)(1)(xiv)]No
Unique name or ID for reciprocating compressor [98.236(p)(1)(i)]FB-C
Total time in operating-mode (hours) [98.236(p)(1)(ii)]4167
Total time in standby-pressurized-mode (hours) [98.236(p)(1)(iii)]4607
Total time in not-operating-depressurized-mode (hours) [98.236(p)(1)(iv)]10
Compressor measured in operating-mode? [98.236(p)(1)(v)]No
Compressor measured in standby-pressurized-mode? [98.236(p)(1)(vi)]No
Compressor measured in not-operating-depressurized-mode? [98.236(p)(1)(vii)]Yes
Compressor had blind flanges installed? [98.236(p)(1)(xii)]No
Power output of compressor driver (hp) [98.236(p)(1)(xiii)]2225
Compressor had scheduled depressurized shutdown during reporting year? [98.236(p)(1)(xiv)]No
Unique name or ID for reciprocating compressor [98.236(p)(1)(i)]FB-D
Total time in operating-mode (hours) [98.236(p)(1)(ii)]3753
Total time in standby-pressurized-mode (hours) [98.236(p)(1)(iii)]5024
Total time in not-operating-depressurized-mode (hours) [98.236(p)(1)(iv)]7
Compressor measured in operating-mode? [98.236(p)(1)(v)]Yes
Compressor measured in standby-pressurized-mode? [98.236(p)(1)(vi)]No
Compressor measured in not-operating-depressurized-mode? [98.236(p)(1)(vii)]No
Compressor had blind flanges installed? [98.236(p)(1)(xii)]No
Power output of compressor driver (hp) [98.236(p)(1)(xiii)]2225
Compressor had scheduled depressurized shutdown during reporting year? [98.236(p)(1)(xiv)]No
Unique name or ID for reciprocating compressor [98.236(p)(1)(i)]FB-E
Total time in operating-mode (hours) [98.236(p)(1)(ii)]5156
Total time in standby-pressurized-mode (hours) [98.236(p)(1)(iii)]3616
Total time in not-operating-depressurized-mode (hours) [98.236(p)(1)(iv)]12
Compressor measured in operating-mode? [98.236(p)(1)(v)]Yes
Compressor measured in standby-pressurized-mode? [98.236(p)(1)(vi)]No
Compressor measured in not-operating-depressurized-mode? [98.236(p)(1)(vii)]No
Compressor had blind flanges installed? [98.236(p)(1)(xii)]No
Power output of compressor driver (hp) [98.236(p)(1)(xiii)]2225
Compressor had scheduled depressurized shutdown during reporting year? [98.236(p)(1)(xiv)]No
Unique name or ID for reciprocating compressor [98.236(p)(1)(i)]FB-B
Total time in operating-mode (hours) [98.236(p)(1)(ii)]4743
Total time in standby-pressurized-mode (hours) [98.236(p)(1)(iii)]4028
Total time in not-operating-depressurized-mode (hours) [98.236(p)(1)(iv)]13
Compressor measured in operating-mode? [98.236(p)(1)(v)]Yes
Compressor measured in standby-pressurized-mode? [98.236(p)(1)(vi)]No
Compressor measured in not-operating-depressurized-mode? [98.236(p)(1)(vii)]No
Compressor had blind flanges installed? [98.236(p)(1)(xii)]No
Power output of compressor driver (hp) [98.236(p)(1)(xiii)]2225
Compressor had scheduled depressurized shutdown during reporting year? [98.236(p)(1)(xiv)]No
Unique name or ID for reciprocating compressor [98.236(p)(1)(i)]FB-F
Total time in operating-mode (hours) [98.236(p)(1)(ii)]3168
Total time in standby-pressurized-mode (hours) [98.236(p)(1)(iii)]5601
Total time in not-operating-depressurized-mode (hours) [98.236(p)(1)(iv)]15
Compressor measured in operating-mode? [98.236(p)(1)(v)]Yes
Compressor measured in standby-pressurized-mode? [98.236(p)(1)(vi)]No
Compressor measured in not-operating-depressurized-mode? [98.236(p)(1)(vii)]No
Compressor had blind flanges installed? [98.236(p)(1)(xii)]No
Power output of compressor driver (hp) [98.236(p)(1)(xiii)]2225
Compressor had scheduled depressurized shutdown during reporting year? [98.236(p)(1)(xiv)]No
Unique name or ID for reciprocating compressor [98.236(p)(1)(i)]C1
Total time in operating-mode (hours) [98.236(p)(1)(ii)]8784
Total time in standby-pressurized-mode (hours) [98.236(p)(1)(iii)]0
Total time in not-operating-depressurized-mode (hours) [98.236(p)(1)(iv)]0
Compressor measured in operating-mode? [98.236(p)(1)(v)]No
Compressor measured in standby-pressurized-mode? [98.236(p)(1)(vi)]No
Compressor measured in not-operating-depressurized-mode? [98.236(p)(1)(vii)]No
Compressor had blind flanges installed? [98.236(p)(1)(xii)]No
Power output of compressor driver (hp) [98.236(p)(1)(xiii)]140
Compressor had scheduled depressurized shutdown during reporting year? [98.236(p)(1)(xiv)]No
Unique name or ID for reciprocating compressor [98.236(p)(1)(i)]C2
Total time in operating-mode (hours) [98.236(p)(1)(ii)]8784
Total time in standby-pressurized-mode (hours) [98.236(p)(1)(iii)]0
Total time in not-operating-depressurized-mode (hours) [98.236(p)(1)(iv)]0
Compressor measured in operating-mode? [98.236(p)(1)(v)]No
Compressor measured in standby-pressurized-mode? [98.236(p)(1)(vi)]No
Compressor measured in not-operating-depressurized-mode? [98.236(p)(1)(vii)]No
Compressor had blind flanges installed? [98.236(p)(1)(xii)]No
Power output of compressor driver (hp) [98.236(p)(1)(xiii)]140
Compressor had scheduled depressurized shutdown during reporting year? [98.236(p)(1)(xiv)]No
Unique name or ID for reciprocating compressor [98.236(p)(1)(i)]C3
Total time in operating-mode (hours) [98.236(p)(1)(ii)]8784
Total time in standby-pressurized-mode (hours) [98.236(p)(1)(iii)]0
Total time in not-operating-depressurized-mode (hours) [98.236(p)(1)(iv)]0
Compressor measured in operating-mode? [98.236(p)(1)(v)]No
Compressor measured in standby-pressurized-mode? [98.236(p)(1)(vi)]No
Compressor measured in not-operating-depressurized-mode? [98.236(p)(1)(vii)]No
Compressor had blind flanges installed? [98.236(p)(1)(xii)]No
Power output of compressor driver (hp) [98.236(p)(1)(xiii)]140
Compressor had scheduled depressurized shutdown during reporting year? [98.236(p)(1)(xiv)]No
Unique name or ID for reciprocating compressor [98.236(p)(1)(i)]DE1
Total time in operating-mode (hours) [98.236(p)(1)(ii)]8784
Total time in standby-pressurized-mode (hours) [98.236(p)(1)(iii)]0
Total time in not-operating-depressurized-mode (hours) [98.236(p)(1)(iv)]0
Compressor measured in operating-mode? [98.236(p)(1)(v)]No
Compressor measured in standby-pressurized-mode? [98.236(p)(1)(vi)]No
Compressor measured in not-operating-depressurized-mode? [98.236(p)(1)(vii)]No
Compressor had blind flanges installed? [98.236(p)(1)(xii)]No
Power output of compressor driver (hp) [98.236(p)(1)(xiii)]350
Compressor had scheduled depressurized shutdown during reporting year? [98.236(p)(1)(xiv)]No
Unique name or ID for reciprocating compressor [98.236(p)(1)(i)]DE2
Total time in operating-mode (hours) [98.236(p)(1)(ii)]8784
Total time in standby-pressurized-mode (hours) [98.236(p)(1)(iii)]0
Total time in not-operating-depressurized-mode (hours) [98.236(p)(1)(iv)]0
Compressor measured in operating-mode? [98.236(p)(1)(v)]No
Compressor measured in standby-pressurized-mode? [98.236(p)(1)(vi)]No
Compressor measured in not-operating-depressurized-mode? [98.236(p)(1)(vii)]No
Compressor had blind flanges installed? [98.236(p)(1)(xii)]No
Power output of compressor driver (hp) [98.236(p)(1)(xiii)]350
Compressor had scheduled depressurized shutdown during reporting year? [98.236(p)(1)(xiv)]No
Unique name or ID for reciprocating compressor [98.236(p)(1)(i)]C4
Total time in operating-mode (hours) [98.236(p)(1)(ii)]8784
Total time in standby-pressurized-mode (hours) [98.236(p)(1)(iii)]0
Total time in not-operating-depressurized-mode (hours) [98.236(p)(1)(iv)]0
Compressor measured in operating-mode? [98.236(p)(1)(v)]No
Compressor measured in standby-pressurized-mode? [98.236(p)(1)(vi)]No
Compressor measured in not-operating-depressurized-mode? [98.236(p)(1)(vii)]No
Compressor had blind flanges installed? [98.236(p)(1)(xii)]No
Power output of compressor driver (hp) [98.236(p)(1)(xiii)]350
Compressor had scheduled depressurized shutdown during reporting year? [98.236(p)(1)(xiv)]No
Unique name or ID for reciprocating compressor [98.236(p)(1)(i)]C5
Total time in operating-mode (hours) [98.236(p)(1)(ii)]8784
Total time in standby-pressurized-mode (hours) [98.236(p)(1)(iii)]0
Total time in not-operating-depressurized-mode (hours) [98.236(p)(1)(iv)]0
Compressor measured in operating-mode? [98.236(p)(1)(v)]No
Compressor measured in standby-pressurized-mode? [98.236(p)(1)(vi)]No
Compressor measured in not-operating-depressurized-mode? [98.236(p)(1)(vii)]No
Compressor had blind flanges installed? [98.236(p)(1)(xii)]No
Power output of compressor driver (hp) [98.236(p)(1)(xiii)]350
Compressor had scheduled depressurized shutdown during reporting year? [98.236(p)(1)(xiv)]No


ReciprocatingCompressorSourceRowDetails:
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]FB-A
Reciprocating compressor source [98.236(p)(2)(i)(B)]Blowdown valve
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]FB-A-BD
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]FB-A
Reciprocating compressor source [98.236(p)(2)(i)(B)]Isolation valve
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]FB-A-IV
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]FB-A
Reciprocating compressor source [98.236(p)(2)(i)(B)]Rod packing
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]FB-A-RP
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]FB-C
Reciprocating compressor source [98.236(p)(2)(i)(B)]Blowdown valve
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]FB-C-BD
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]FB-C
Reciprocating compressor source [98.236(p)(2)(i)(B)]Isolation valve
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]FB-C-IV
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]FB-C
Reciprocating compressor source [98.236(p)(2)(i)(B)]Rod packing
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]FB-C-RP
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]FB-D
Reciprocating compressor source [98.236(p)(2)(i)(B)]Blowdown valve
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]FB-D-BD
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]FB-D
Reciprocating compressor source [98.236(p)(2)(i)(B)]Isolation valve
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]FB-D-IV
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]FB-D
Reciprocating compressor source [98.236(p)(2)(i)(B)]Rod packing
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]FB-D-RP
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]FB-E
Reciprocating compressor source [98.236(p)(2)(i)(B)]Blowdown valve
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]FB-E-BD
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]FB-E
Reciprocating compressor source [98.236(p)(2)(i)(B)]Isolation valve
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]FB-E-IV
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]FB-E
Reciprocating compressor source [98.236(p)(2)(i)(B)]Rod packing
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]FB-E-RP
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]FB-B
Reciprocating compressor source [98.236(p)(2)(i)(B)]Blowdown valve
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]FB-B-BD
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]FB-B
Reciprocating compressor source [98.236(p)(2)(i)(B)]Isolation valve
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]FB-B-IV
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]FB-B
Reciprocating compressor source [98.236(p)(2)(i)(B)]Rod packing
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]FB-B-RP
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]FB-F
Reciprocating compressor source [98.236(p)(2)(i)(B)]Blowdown valve
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]FB-F-BD
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]FB-F
Reciprocating compressor source [98.236(p)(2)(i)(B)]Isolation valve
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]FB-F-IV
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]FB-F
Reciprocating compressor source [98.236(p)(2)(i)(B)]Rod packing
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]FB-F-RP
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]C1
Reciprocating compressor source [98.236(p)(2)(i)(B)]Blowdown valve
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]C1-BD
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]C1
Reciprocating compressor source [98.236(p)(2)(i)(B)]Isolation valve
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]C1-IV
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]C1
Reciprocating compressor source [98.236(p)(2)(i)(B)]Rod packing
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]C1-RP
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]C2
Reciprocating compressor source [98.236(p)(2)(i)(B)]Blowdown valve
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]C2-BD
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]C2
Reciprocating compressor source [98.236(p)(2)(i)(B)]Isolation valve
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]C2-IV
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]C2
Reciprocating compressor source [98.236(p)(2)(i)(B)]Rod packing
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]C2-RP
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]C3
Reciprocating compressor source [98.236(p)(2)(i)(B)]Blowdown valve
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]C3-BD
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]C3
Reciprocating compressor source [98.236(p)(2)(i)(B)]Isolation valve
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]C3-IV
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]C3
Reciprocating compressor source [98.236(p)(2)(i)(B)]Rod packing
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]C3-RP
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]DE1
Reciprocating compressor source [98.236(p)(2)(i)(B)]Blowdown valve
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]DE1-BD
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]DE1
Reciprocating compressor source [98.236(p)(2)(i)(B)]Isolation valve
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]DE1-IV
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]DE1
Reciprocating compressor source [98.236(p)(2)(i)(B)]Rod packing
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]DE1-RP
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]DE2
Reciprocating compressor source [98.236(p)(2)(i)(B)]Blowdown valve
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]DE2-BD
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]DE2
Reciprocating compressor source [98.236(p)(2)(i)(B)]Isolation valve
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]DE2-IV
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]DE2
Reciprocating compressor source [98.236(p)(2)(i)(B)]Rod packing
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]DE2-RP
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]C4
Reciprocating compressor source [98.236(p)(2)(i)(B)]Blowdown valve
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]C4-BD
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]C4
Reciprocating compressor source [98.236(p)(2)(i)(B)]Isolation valve
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]C4-IV
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]C4
Reciprocating compressor source [98.236(p)(2)(i)(B)]Rod packing
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]C4-RP
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]C5
Reciprocating compressor source [98.236(p)(2)(i)(B)]Blowdown valve
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]C5-BD
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]C5
Reciprocating compressor source [98.236(p)(2)(i)(B)]Isolation valve
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]C5-IV
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]C5
Reciprocating compressor source [98.236(p)(2)(i)(B)]Rod packing
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]C5-RP


ReciprocatingCompressorsLeakOrVentSampleDataRowDetails:
Unique Name or ID for leak or vent (Specify) [98.236(p)(2)(i)(C)] [98.236(p)(3)(i)(A)]FB-A-BD
Measurement date (mm/dd/yyyy) [98.236(p)(3)(i)(B)]2020-08-12
Measurement method [98.236(p)(3)(i)(C)]Screening/Optical gas imaging
Measured flow rate (standard cubic feet/hour) [98.236(p)(3)(i)(D)]0
Is the measurement location prior to or after commingling with non-compressor emission sources? [98.236(p)(3)(i)(F)]Prior to commingling
Compressors in “Operating mode”FB-A
Unique Name or ID for leak or vent (Specify) [98.236(p)(2)(i)(C)] [98.236(p)(3)(i)(A)]FB-A-RP
Measurement date (mm/dd/yyyy) [98.236(p)(3)(i)(B)]2020-08-12
Measurement method [98.236(p)(3)(i)(C)]Temporary meter
Measured flow rate (standard cubic feet/hour) [98.236(p)(3)(i)(D)]13.6
Is the measurement location prior to or after commingling with non-compressor emission sources? [98.236(p)(3)(i)(F)]Prior to commingling
Compressors in “Operating mode”FB-A
Unique Name or ID for leak or vent (Specify) [98.236(p)(2)(i)(C)] [98.236(p)(3)(i)(A)]FB-C-BD
Measurement date (mm/dd/yyyy) [98.236(p)(3)(i)(B)]2020-08-12
Measurement method [98.236(p)(3)(i)(C)]Screening/Optical gas imaging
Measured flow rate (standard cubic feet/hour) [98.236(p)(3)(i)(D)]0
Is the measurement location prior to or after commingling with non-compressor emission sources? [98.236(p)(3)(i)(F)]Prior to commingling
Compressors in “Operating mode”FB-C
Unique Name or ID for leak or vent (Specify) [98.236(p)(2)(i)(C)] [98.236(p)(3)(i)(A)]FB-C-RP
Measurement date (mm/dd/yyyy) [98.236(p)(3)(i)(B)]2020-08-12
Measurement method [98.236(p)(3)(i)(C)]Temporary meter
Measured flow rate (standard cubic feet/hour) [98.236(p)(3)(i)(D)]251.9
Is the measurement location prior to or after commingling with non-compressor emission sources? [98.236(p)(3)(i)(F)]Prior to commingling
Compressors in “Operating mode”FB-C
Unique Name or ID for leak or vent (Specify) [98.236(p)(2)(i)(C)] [98.236(p)(3)(i)(A)]FB-D-BD
Measurement date (mm/dd/yyyy) [98.236(p)(3)(i)(B)]2020-08-12
Measurement method [98.236(p)(3)(i)(C)]Temporary meter
Measured flow rate (standard cubic feet/hour) [98.236(p)(3)(i)(D)]157.3
Is the measurement location prior to or after commingling with non-compressor emission sources? [98.236(p)(3)(i)(F)]Prior to commingling
Compressors in *Standby-pressurized mode*FB-D
Unique Name or ID for leak or vent (Specify) [98.236(p)(2)(i)(C)] [98.236(p)(3)(i)(A)]FB-E-BD
Measurement date (mm/dd/yyyy) [98.236(p)(3)(i)(B)]2020-08-12
Measurement method [98.236(p)(3)(i)(C)]Temporary meter
Measured flow rate (standard cubic feet/hour) [98.236(p)(3)(i)(D)]27.5
Is the measurement location prior to or after commingling with non-compressor emission sources? [98.236(p)(3)(i)(F)]Prior to commingling
Compressors in *Standby-pressurized mode*FB-E
Unique Name or ID for leak or vent (Specify) [98.236(p)(2)(i)(C)] [98.236(p)(3)(i)(A)]FB-B-BD
Measurement date (mm/dd/yyyy) [98.236(p)(3)(i)(B)]2020-08-12
Measurement method [98.236(p)(3)(i)(C)]Screening/Optical gas imaging
Measured flow rate (standard cubic feet/hour) [98.236(p)(3)(i)(D)]0
Is the measurement location prior to or after commingling with non-compressor emission sources? [98.236(p)(3)(i)(F)]Prior to commingling
Compressors in *Standby-pressurized mode*FB-B
Unique Name or ID for leak or vent (Specify) [98.236(p)(2)(i)(C)] [98.236(p)(3)(i)(A)]FB-F-BD
Measurement date (mm/dd/yyyy) [98.236(p)(3)(i)(B)]2020-08-12
Measurement method [98.236(p)(3)(i)(C)]Screening/Optical gas imaging
Measured flow rate (standard cubic feet/hour) [98.236(p)(3)(i)(D)]0
Is the measurement location prior to or after commingling with non-compressor emission sources? [98.236(p)(3)(i)(F)]Prior to commingling
Compressors in *Standby-pressurized mode*FB-F


ReciprocatingCompressorsEmissionFactorsSampleDataRowDetails:
Compressor Mode [98.236(p)(3)(ii)(A)]Operating
Compressor Source [98.236(p)(3)(ii)(A)]Blowdown valve
Compressor mode-source combination reporter emission factor, EFs,m (standard cubic feet per hour) [98.236(p)(3)(ii)(B)]32.83125
Total number of compressors measured in the compressor mode-source combination in current reporting year and preceding two reporting years, Countm [98.236(p)(3)(ii)(C)]12
Is the reporter emission factor facility-specific or based on all of the reporter's applicable facilities? [98.236(p)(3)(ii)(D)]Facility-specific
Compressor Mode [98.236(p)(3)(ii)(A)]Operating
Compressor Source [98.236(p)(3)(ii)(A)]Rod packing
Compressor mode-source combination reporter emission factor, EFs,m (standard cubic feet per hour) [98.236(p)(3)(ii)(B)]165.2666667
Total number of compressors measured in the compressor mode-source combination in current reporting year and preceding two reporting years, Countm [98.236(p)(3)(ii)(C)]12
Is the reporter emission factor facility-specific or based on all of the reporter's applicable facilities? [98.236(p)(3)(ii)(D)]Facility-specific
Compressor Mode [98.236(p)(3)(ii)(A)]Standby-pressurized
Compressor Source [98.236(p)(3)(ii)(A)]Blowdown valve
Compressor mode-source combination reporter emission factor, EFs,m (standard cubic feet per hour) [98.236(p)(3)(ii)(B)]0
Total number of compressors measured in the compressor mode-source combination in current reporting year and preceding two reporting years, Countm [98.236(p)(3)(ii)(C)]4
Is the reporter emission factor facility-specific or based on all of the reporter's applicable facilities? [98.236(p)(3)(ii)(D)]Facility-specific
Compressor Mode [98.236(p)(3)(ii)(A)]Not-operating-depressurized
Compressor Source [98.236(p)(3)(ii)(A)]Isolation valve
Compressor mode-source combination reporter emission factor, EFs,m (standard cubic feet per hour) [98.236(p)(3)(ii)(B)]0
Total number of compressors measured in the compressor mode-source combination in current reporting year and preceding two reporting years, Countm [98.236(p)(3)(ii)(C)]2
Is the reporter emission factor facility-specific or based on all of the reporter's applicable facilities? [98.236(p)(3)(ii)(D)]Facility-specific


ReciprocatingCompressorsLeakOrVentDataRowDetails:
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]FB-A-BD
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]Yes
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)]0
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)]0
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]FB-A-IV
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]No
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)]0
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)]0
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]FB-A-RP
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]Yes
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)]0.1824774
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)]0.9512368
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]FB-C-BD
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]Yes
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)]0
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)]0
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]FB-C-IV
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]No
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)]0
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)]0
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]FB-C-RP
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]Yes
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)]0
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)]0
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]FB-D-BD
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]Yes
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)]0
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)]0
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]FB-D-IV
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]No
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)]0
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)]0
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]FB-D-RP
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]No
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)]1.1662158
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)]6.0793694
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]FB-E-BD
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]Yes
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)]0
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)]0
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]FB-E-IV
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]No
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)]0
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)]0
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]FB-E-RP
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]No
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)]0
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)]0
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]FB-B-BD
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]Yes
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)]0
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)]0
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]FB-B-IV
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]No
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)]0
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)]0
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]FB-B-RP
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]No
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)]2.4490062
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)]12.7664307
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]FB-F-BD
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]Yes
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)]0
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)]0
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]FB-F-IV
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]No
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)]0
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)]0
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]FB-F-RP
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]No
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)]1.7531651
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)]9.1390791
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]C1-BD
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Flare
Percentage of time the device was operational when compressor source emissions were routed to device [98.236(p)(2)(ii)(E)]100
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]C1-IV
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Flare
Percentage of time the device was operational when compressor source emissions were routed to device [98.236(p)(2)(ii)(E)]100
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]C1-RP
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Flare
Percentage of time the device was operational when compressor source emissions were routed to device [98.236(p)(2)(ii)(E)]100
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]C2-BD
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Flare
Percentage of time the device was operational when compressor source emissions were routed to device [98.236(p)(2)(ii)(E)]100
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]C2-IV
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Flare
Percentage of time the device was operational when compressor source emissions were routed to device [98.236(p)(2)(ii)(E)]100
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]C2-RP
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Flare
Percentage of time the device was operational when compressor source emissions were routed to device [98.236(p)(2)(ii)(E)]100
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]C3-BD
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Flare
Percentage of time the device was operational when compressor source emissions were routed to device [98.236(p)(2)(ii)(E)]100
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]C3-IV
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Flare
Percentage of time the device was operational when compressor source emissions were routed to device [98.236(p)(2)(ii)(E)]100
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]C3-RP
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Flare
Percentage of time the device was operational when compressor source emissions were routed to device [98.236(p)(2)(ii)(E)]100
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]DE1-BD
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Flare
Percentage of time the device was operational when compressor source emissions were routed to device [98.236(p)(2)(ii)(E)]100
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]DE1-IV
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Flare
Percentage of time the device was operational when compressor source emissions were routed to device [98.236(p)(2)(ii)(E)]100
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]DE1-RP
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Flare
Percentage of time the device was operational when compressor source emissions were routed to device [98.236(p)(2)(ii)(E)]100
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]DE2-BD
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Flare
Percentage of time the device was operational when compressor source emissions were routed to device [98.236(p)(2)(ii)(E)]100
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]DE2-IV
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Flare
Percentage of time the device was operational when compressor source emissions were routed to device [98.236(p)(2)(ii)(E)]100
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]DE2-RP
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Flare
Percentage of time the device was operational when compressor source emissions were routed to device [98.236(p)(2)(ii)(E)]100
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]C4-BD
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Flare
Percentage of time the device was operational when compressor source emissions were routed to device [98.236(p)(2)(ii)(E)]100
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]C4-IV
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Flare
Percentage of time the device was operational when compressor source emissions were routed to device [98.236(p)(2)(ii)(E)]100
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]C4-RP
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Flare
Percentage of time the device was operational when compressor source emissions were routed to device [98.236(p)(2)(ii)(E)]100
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]C5-BD
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Flare
Percentage of time the device was operational when compressor source emissions were routed to device [98.236(p)(2)(ii)(E)]100
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]C5-IV
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Flare
Percentage of time the device was operational when compressor source emissions were routed to device [98.236(p)(2)(ii)(E)]100
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]C5-RP
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Flare
Percentage of time the device was operational when compressor source emissions were routed to device [98.236(p)(2)(ii)(E)]100


OtherEmissionsFromEquipmentLeaksDetails:
mt CO21.8
mt CH431.48
Did this facility use leak surveys to calculate emissions from equipment leaks in accordance with 98.232 [per 98.236(q)]?Yes
Were missing data procedures used for any parameters to calculate GHG emissions? [98.235]No
Number of complete equipment leak surveys performed during the calendar year [98.236(q)(1)(i)]1
Optical gas imaging instrument as specified in §60.18 [98.234(a)(1)]Yes
Method 21 [98.234(a)(2)]No
Infrared laser beam illuminated instrument [98.234(a)(3)]No
Acoustic leak detection device [98.234(a)(5)]No
Optical gas imaging instrument as specified in §60.5397a [98.234(a)(6)]No
Method 21 as specified in §60.5397a [98.234(a)(7)]No


GasProcessingEmissionsFactorsRowDetails:
Component Type [98.236(q)(2)(i)]Compressor Components, Gas Service - Valve
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)]0
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)]8760
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)]0
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)]0
Component Type [98.236(q)(2)(i)]Compressor Components, Gas Service - Connector
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)]2
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)]8760
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)]0.1083544
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)]1.5872284
Component Type [98.236(q)(2)(i)]Compressor Components, Gas Service - Open-ended Line
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)]0
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)]8760
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)]0
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)]0
Component Type [98.236(q)(2)(i)]Compressor Components, Gas Service - Pressure Relief Valve
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)]3
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)]8760
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)]0.8461126
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)]15.3969641
Component Type [98.236(q)(2)(i)]Compressor Components, Gas Service - Meter
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)]0
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)]8760
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)]0
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)]0
Component Type [98.236(q)(2)(i)]Non-Compressor Components, Gas Service - Valve
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)]3
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)]8760
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)]0.1700979
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)]2.6536986
Component Type [98.236(q)(2)(i)]Non-Compressor Components, Gas Service - Connector
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)]15
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)]8760
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)]0.6532928
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)]11.2989882
Component Type [98.236(q)(2)(i)]Non-Compressor Components, Gas Service - Open-ended Line
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)]0
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)]8760
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)]0
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)]0
Component Type [98.236(q)(2)(i)]Non-Compressor components, Gas Service - Pressure Relief Valve
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)]2
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)]8760
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)]0.0337744
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)]0.5454705
Component Type [98.236(q)(2)(i)]Non-Compressor components, Gas Service - Meter
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)]0
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)]8760
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)]0
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)]0