Facility Name:Targa Gas Processing LLC - Longhorn Gas Plant
Facility Identifier:
Facility Reporting Year:2020
Facility Location:
Address: 33.310930/-97.526777
City: Decatur
State: TX
Postal Code: 76234

Facility Site Details:
CO2 equivalent emissions from facility subparts C-II, SS, and TT (metric tons):68,595.14
CO2 equivalent emissions from supplier subparts LL-QQ (metric tons):
Biogenic CO2 emissions from facility subparts C-II, SS, and TT (metric tons):0
Cogeneration Unit Emissions Indicator:N
GHG Report Start Date:2020-01-01
GHG Report End Date:2020-12-31
Description of Changes to Calculation Methodology:
Plant Code Indicator:N
Primary NAICS Code:211130
Second Primary NAICS Code:

Parent Company Details:
Parent Company Name:TARGA RESOURCES CORP
Address:811 Louisiana Street, Suite 2100, Houston,  TX 77002
Percent Ownership Interest:100

Subpart C: General Stationary Fuel Combustion

Gas Information Details

Gas NameCarbon Dioxide
Gas Quantity22,816.75508 (Metric Tons)
Own Result?

Gas NameBiogenic Carbon dioxide
Gas Quantity0 (Metric Tons)
Own Result?

Gas NameMethane
Gas Quantity0.430018 (Metric Tons)
Own Result?

Gas NameNitrous Oxide
Gas Quantity0.043002 (Metric Tons)
Own Result?

Unit Details:
Unit Name : CP-master fuel meter
Unit Type : OCS (Other combustion source)
Unit Description :
Other Unit Name :
Common Pipe Details:
Use Ivt Indicator: N
Maximum Rated Heat Input Capacity: 98
Cumulative Maximum Rated Heat Input Capacity: 112.4

Emission Details:
Annual CO2 mass emissions from sorbent: 0 (Metric Tons)
Annual Biogenic CO2 Emissions: 0 (metric tons)
Annual Fossil fuel based CO2 Emissions: 22816.75508 (metric tons)

Tier Fuel Details:
Fuel : Natural Gas (Weighted U.S. Average)
Tier Name : Tier 2 (Equation C-2a)
Tier Methodology Start Date : 2020-01-01
Tier Methodology End Date : 2020-12-31
Frequency of HHV determinations : Monthly

Tier 2 Monthly HHV Details :
JanuaryFebruaryMarchAprilMayJuneJulyAugustSeptemberOctoberNovemberDecember
N N N N N N N N N N N N

Fuel Emission Details :
Total CO2 emissionsTotal CH4 emissionsTotal N2O emissionsTotal CH4 emissions CO2eTotal N2O emissions CO2e
22816.75508 (Metric Tons) 0.430018 (Metric Tons) 0.0430018 (Metric Tons) 10.75045 (Metric Tons) 12.8145364 (Metric Tons)

Equation C2a/C9a Inputs :
Fuel Quantity : 422000000 ()
Use Default High Heat Value : false
Equation C2b Inputs :
Fuel CombustedHigh Heat Value
January35166666.6666667 ()0.001019 ()
February35166666.6666667 ()0.001019 ()
March35166666.6666667 ()0.001019 ()
April35166666.6666667 ()0.001019 ()
May35166666.6666667 ()0.001019 ()
June35166666.6666667 ()0.001019 ()
July35166666.6666667 ()0.001019 ()
August35166666.6666667 ()0.001019 ()
September35166666.6666667 ()0.001019 ()
October35166666.6666667 ()0.001019 ()
November35166666.6666667 ()0.001019 ()
December35166666.6666667 ()0.001019 ()


Subpart W: Petroleum and Natural Gas Systems

Gas Information Details

Gas NameCarbon Dioxide
Gas Quantity44,826.091884 (Metric Tons)
Own Result?

Gas NameMethane
Gas Quantity37.138841 (Metric Tons)
Own Result?

Gas NameNitrous Oxide
Gas Quantity0.000864 (Metric Tons)
Own Result?


SubpartWSummaryDetails:
Industry Segment Number3
Industry Segment NameOnshore natural gas processing [98.230(a)(3)]
Total Reported CO2 Emissions (mt CO2)44826.0918836207
Total CO2e Emissions (mt CO2e)45754.8203211879
Total Reported CH4 Emissions (mt CH4)37.1388405555435
Total Reported N2O Emissions (mt N2O)0.000863837847514046


SubpartWSourceReportingFormRowDetails:
Source Reporting FormOnshore Production [98.236(aa)(1)]
Required for Selected Industry SegmentNo
Source Reporting FormFacility Overview [98.236(aa)(2-11)]
Required for Selected Industry SegmentYes
Source Reporting FormNatural Gas Pneumatic Devices [98.236(b)]
Required for Selected Industry SegmentNo
Total Reported CO2 Emissions (mt CO2)0
Total Reported CH4 Emissions (mt CH4)0
Source Reporting FormNatural Gas Driven Pneumatic Pumps [98.236(c)]
Required for Selected Industry SegmentNo
Total Reported CO2 Emissions (mt CO2)0
Total Reported CH4 Emissions (mt CH4)0
Source Reporting FormAcid Gas Removal Units [98.236(d)]
Required for Selected Industry SegmentYes
Total Reported CO2 Emissions (mt CO2)44217.3414818242
Source Reporting FormDehydrators [98.236(e)]
Required for Selected Industry SegmentYes
Total Reported CO2 Emissions (mt CO2)0.2733682751424
Total Reported CH4 Emissions (mt CH4)0.0193644690016
Total Reported N2O Emissions (mt N2O)0
Source Reporting FormWell Venting for Liquids Unloading [98.236(f)]
Required for Selected Industry SegmentNo
Total Reported CO2 Emissions (mt CO2)0
Total Reported CH4 Emissions (mt CH4)0
Source Reporting FormCompletions and Workovers with Hydraulic Fracturing [98.236(g)]
Required for Selected Industry SegmentNo
Total Reported CO2 Emissions (mt CO2)0
Total Reported CH4 Emissions (mt CH4)0
Total Reported N2O Emissions (mt N2O)0
Source Reporting FormCompletions and Workovers without Hydraulic Fracturing [98.236(h)]
Required for Selected Industry SegmentNo
Total Reported CO2 Emissions (mt CO2)0
Total Reported CH4 Emissions (mt CH4)0
Total Reported N2O Emissions (mt N2O)0
Source Reporting FormBlowdown Vent Stacks [98.236(i)]
Required for Selected Industry SegmentYes
Total Reported CO2 Emissions (mt CO2)0
Total Reported CH4 Emissions (mt CH4)0
Source Reporting FormAtmospheric Storage Tanks [98.236(j)]
Required for Selected Industry SegmentNo
Total Reported CO2 Emissions (mt CO2)0
Total Reported CH4 Emissions (mt CH4)0
Total Reported N2O Emissions (mt N2O)0
Source Reporting FormTransmission Storage Tanks [98.236(k)]
Required for Selected Industry SegmentNo
Total Reported CO2 Emissions (mt CO2)0
Total Reported CH4 Emissions (mt CH4)0
Total Reported N2O Emissions (mt N2O)0
Source Reporting FormWell Testing [98.236(l)]
Required for Selected Industry SegmentNo
Total Reported CO2 Emissions (mt CO2)0
Total Reported CH4 Emissions (mt CH4)0
Total Reported N2O Emissions (mt N2O)0
Source Reporting FormAssociated Gas Venting and Flaring [98.236(m)]
Required for Selected Industry SegmentNo
Total Reported CO2 Emissions (mt CO2)0
Total Reported CH4 Emissions (mt CH4)0
Total Reported N2O Emissions (mt N2O)0
Source Reporting FormFlare Stacks [98.236(n)]
Required for Selected Industry SegmentYes
Total Reported CO2 Emissions (mt CO2)607.181053283837
Total Reported CH4 Emissions (mt CH4)2.11254575311473
Total Reported N2O Emissions (mt N2O)0.000863837847514046
Source Reporting FormCentrifugal Compressors [98.236(o)]
Required for Selected Industry SegmentYes
Total Reported CO2 Emissions (mt CO2)0
Total Reported CH4 Emissions (mt CH4)0
Source Reporting FormReciprocating Compressors [98.236(p)]
Required for Selected Industry SegmentYes
Total Reported CO2 Emissions (mt CO2)0.00210800085189451
Total Reported CH4 Emissions (mt CH4)24.9048678593408
Source Reporting FormEquipment Leaks Surveys and Population Counts [98.236(q,r)]
Required for Selected Industry SegmentYes
Total Reported CO2 Emissions (mt CO2)1.2938722366896
Total Reported CH4 Emissions (mt CH4)10.1020624740864
Source Reporting FormOffshore Petroleum and Natural Gas Production [98.236(s)]
Required for Selected Industry SegmentNo
Total Reported CO2 Emissions (mt CO2)0
Total Reported CH4 Emissions (mt CH4)0
Total Reported N2O Emissions (mt N2O)0
Source Reporting FormEnhanced Oil Recovery Injection Pumps [98.236(w)]
Required for Selected Industry SegmentNo
Total Reported CO2 Emissions (mt CO2)0
Source Reporting FormEnhanced Oil Recovery Hydrocarbon Liquids [98.236(x)]
Required for Selected Industry SegmentNo
Total Reported CO2 Emissions (mt CO2)0
Source Reporting FormCombustion Equipment at Onshore Petroleum and Natural Gas Production Facilities, Onshore Petroleum and Natural Gas Gathering and Boosting Facilities, and Natural gas Distribution Facilities [98.236(z)]
Required for Selected Industry SegmentNo
Total Reported CO2 Emissions (mt CO2)0
Total Reported CH4 Emissions (mt CH4)0
Total Reported N2O Emissions (mt N2O)0


FacilityOverviewDetails:


FacilityOverviewNaturalGasProcessingRowDetails:
Average mole fraction of CH4 in natural gas received [98.236(aa)(3)(v)]0.75869
Average mole fraction of CO2 in natural gas received [98.236(aa)(3)(vi)]0.03547
Does the facility fractionate NGLs? [98.236(aa)(3)(vii)]No


AcidGasRemovalUnitsDetails:
mt CO244217.3414818242
Did the Facility have any acid gas removal units that vent directly to the atmosphere, to a flare or engine, or to a sulfur recovery plant subject to reporting under 98.232 [98.236(d)]?Yes
Were missing data procedures used for any parameters to calculate GHG emissions? [98.235]No


AcidGasInfoRowDetails:
Unit ID or Name [98.236(d)(1)(i)]AMN_Amine Still Vent to Flare
Total feed rate entering the acid gas removal unit for the year (million cubic feet) [98.236(d)(1)(ii)]608
Calculation Method Used (Select from list) [98.236(d)(1)(iii)]Calculation Methodology 2 [98.233(d)(2)]
Are any CO2 emissions from the acid gas removal unit recovered and transferred outside the facility? (Yes / No) [98.236(d)(1)(iv)]No
Total CO2 Emissions (mt CO2) [98.236(d)(1)(v)]1012.97507689521
Unit ID or Name [98.236(d)(1)(i)]AMN_Amine Still Vent to RTO
Total feed rate entering the acid gas removal unit for the year (million cubic feet) [98.236(d)(1)(ii)]25950
Calculation Method Used (Select from list) [98.236(d)(1)(iii)]Calculation Methodology 2 [98.233(d)(2)]
Are any CO2 emissions from the acid gas removal unit recovered and transferred outside the facility? (Yes / No) [98.236(d)(1)(iv)]No
Total CO2 Emissions (mt CO2) [98.236(d)(1)(v)]43204.366404929


AcidGasCalcMethod2EmissionsRowDetails:
Unit ID or Name [98.236(d)(1)(i)]AMN_Amine Still Vent to Flare
Annual average fraction of CO2 content in the vent from the acid gas removal unit, VolCO2 (volumetric fraction) [98.236(d)(2)(i)(A)]0.9741
Annual volume of gas vented from the acid gas removal unit, Vs (actual or standard cubic feet) [98.236(d)(2)(i)(B)]20531000
Annual volume of gas vented reported on an Actual or Standard basis? [98.236]Standard
Temperature used to calculate volume of gas vented (°F) [98.236]80
Pressure used to calculate volume of gas vented (psi) [98.236]14.7
Unit ID or Name [98.236(d)(1)(i)]AMN_Amine Still Vent to RTO
Annual average fraction of CO2 content in the vent from the acid gas removal unit, VolCO2 (volumetric fraction) [98.236(d)(2)(i)(A)]0.9741
Annual volume of gas vented from the acid gas removal unit, Vs (actual or standard cubic feet) [98.236(d)(2)(i)(B)]875667000
Annual volume of gas vented reported on an Actual or Standard basis? [98.236]Standard
Temperature used to calculate volume of gas vented (°F) [98.236]80
Pressure used to calculate volume of gas vented (psi) [98.236]14.7


DehydratorsDetails:
mt CO20.2733682751424
mt CH40.0193644690016
mt N2O0
Did the facility have any glycol dehydrators with annual average daily natural gas throughputs greater than or equal to 0.4MMscfd subject to reporting under 98.232 [98.236(e)]?Yes
Did the facility have any glycol dehydrators with annual average daily natural gas throughputs less than 0.4MMscfd subject to reporting under 98.232 [98.236(e)]?No
Did the facility have any desiccant dehydrators subject to reporting under 98.232 [98.236(e)]?Yes
Were missing data procedures used for any parameters to calculate GHG emissions? [98.235]No


SmallGlycolDehydrators:
Emissions vented to flare or regenerator firebox/fire tubes
Emissions that were not vented to a flare or regenerator firebox/fire tubes


DessicantDehydrators:
Total Number of Desiccant Dehydrators [98.236(e)(3)(i)]3
Vapor RecoveryNo
Dehydrator vents to flares or regenerator firebox/fire tubesNo
Control devices other than vapor recovery, flare or regenerator firebox/fire tubesNo
Emissions vented to flare or regenerator firebox/fire tubes
Emissions that were not vented to a flare or regenerator firebox/fire tubes
Total CO2 Emissions (mt CO2) [98.236(e)(3)(i)] [98.236(e)(3)(ii)]0.0004835951424
Total CH4 Emissions (mt CH4) [98.236(e)(3)(i)] [98.236(e)(3)(iii)]0.0037757270016


GlycolDehydratorsMoreThanSpecifiedValueRowDetails:
Unit ID or Name [98.236(e)(1)(i)]DEHY_Glycol Dehydrator
Glycol dehydrator feed natural gas flow rate determined by engineering estimate based on best available data (MMscfd) [98.236(e)(1)(ii)]88.53
Dehydrator feed natural gas water content (pounds per MMscf) [98.236(e)(1)(iii)]120.38
Dehydrator outlet natural gas water content (pounds per MMscf) [98.236(e)(1)(iv)]7
Glycol dehydrator absorbent circulation pump type [98.236(e)(1)(v)]Electric
Dehydrator absorbent circulation rate (gallons per minute) [98.236(e)(1)(vi)]3
Report type of absorbent used [98.236(e)(1)(vii)]Triethylene glycol (TEG)
Report whether stripper gas is used in glycol dehydrator [98.236(e)(1)(viii)]No
Report whether a flash tank separator is used in glycol dehydrator [98.236(e)(1)(ix)]Yes
Total time the glycol dehydrator is operating (hours) [98.236(e)(1)(x)]7200
Temperature of the wet natural gas (°F) [98.236(e)(1)(xi)]124
Pressure of the wet natural gas (psig) [98.236(e)(1)(xii)]30
Concentration of CO2 in wet natural gas (mole fraction) [98.236(e)(1)(xiv)]0.03547
Concentration of CH4 in wet natural gas (mole fraction) [98.236(e)(1)(xiii)]0.75869
Were any dehydrator emissions vented to a vapor recovery device? [98.236(e)(1)(xv)]No
Were any dehydrator emissions vented to a flare or regenerator firebox/fire tubes? [98.236(e)(1)(xvi)]No
Were any dehydrator emissions vented to the atmosphere without being routed to a flare or regenerator firebox/fire tubes? [98.236(e)(1)(xvii)]Yes
CO2 Emissions from Venting (mt CO2) [98.236(e)(1)(xvii)(A)]0.27288468
CH4 Emissions from Venting (mt CH4) [98.236(e)(1)(xvii)(B)]0.015588742


BlowdownVentStacksDetails:
mt CO20
mt CH40
Did the facility have any blowdown vent stacks subject to reporting under 98.232 [98.236(i)]?No


FlareStacksDetails:
mt CO2607.181053283837
mt CH42.11254575311473
mt N2O0.000863837847514046
Did the facility have flare stacks subject to reporting under 98.232 [98.236(n)]?Yes
Were missing data procedures used for any parameters to calculate GHG emissions? [98.235]No


UniqueFlareStacksRowDetails:
Unique Name or ID Number for the Flare Stack [98.236(n)(1)]FLARE_Flare-1 (FL-1)
Does the flare stack have a continuous flow monitor on gas to the flare? [98.236(n)(2)]Yes
Does the flare stack have a continuous gas analyzer on gas to the flare? [98.236(n)(3)]No
Were CEMS used to measure CO2 emissions for the flare stack? [98.233(n)(8)] [98.236(n)(12)]No
Volume of gas sent to flare, Vs (standard cubic feet) [98.236(n)(4)]7776000
Flare combustion efficiency (decimal value) [98.236(n)(6)]0.98
Mole fraction of CH4 in flare feed gas, XCH4 [98.236(n)(7)]0.7204
Mole fraction of CO2 in flare feed gas, XCO2 [98.236(n)(8)]0
Fraction of feed gas sent to un-lit flare, Zu [98.236(n)(5)]0
CO2 emissions (mt CO2) [98.236(n)(9)]466.228075738637
CH4 Emissions (mt CH4) (Eq. W-19) [98.236(n)(10)]2.07138367951473
N2O Emissions (mt N2O) (Eq. W-40) [98.236(n)(11)]0.000824914718858446
Unique Name or ID Number for the Flare Stack [98.236(n)(1)]FLARE_Flare-2 (FL-2)
Does the flare stack have a continuous flow monitor on gas to the flare? [98.236(n)(2)]Yes
Does the flare stack have a continuous gas analyzer on gas to the flare? [98.236(n)(3)]No
Were CEMS used to measure CO2 emissions for the flare stack? [98.233(n)(8)] [98.236(n)(12)]No
Volume of gas sent to flare, Vs (standard cubic feet) [98.236(n)(4)]22807000
Flare combustion efficiency (decimal value) [98.236(n)(6)]0.98
Mole fraction of CH4 in flare feed gas, XCH4 [98.236(n)(7)]0.0047
Mole fraction of CO2 in flare feed gas, XCO2 [98.236(n)(8)]0.9741
Fraction of feed gas sent to un-lit flare, Zu [98.236(n)(5)]0
CO2 emissions (mt CO2) [98.236(n)(9)]140.9529775452
CH4 Emissions (mt CH4) (Eq. W-19) [98.236(n)(10)]0.0411620736
N2O Emissions (mt N2O) (Eq. W-40) [98.236(n)(11)]0.00004


CentrifugalCompressorsDetails:
mt CO20
mt CH40
Did the facility have any centrifugal compressors subject to reporting under 98.232 [98.236(o)]?No


ReciprocatingCompressorsDetails:
mt CO20.00210800085189451
mt CH424.9048678593408
Did the facility have any reciprocating compressors subject to reporting under 98.232 [98.236(p)]?Yes
Were missing data procedures used for any parameters to calculate GHG emissions? [98.235]No


ReciprocatingCompressorsActivityDataRowDetails:
Unique name or ID for reciprocating compressor [98.236(p)(1)(i)]RECIP_Compressor ENG 1100
Total time in operating-mode (hours) [98.236(p)(1)(ii)]3583
Total time in standby-pressurized-mode (hours) [98.236(p)(1)(iii)]0
Total time in not-operating-depressurized-mode (hours) [98.236(p)(1)(iv)]5201
Compressor measured in operating-mode? [98.236(p)(1)(v)]No
Compressor measured in standby-pressurized-mode? [98.236(p)(1)(vi)]No
Compressor measured in not-operating-depressurized-mode? [98.236(p)(1)(vii)]No
Compressor had blind flanges installed? [98.236(p)(1)(xii)]No
Power output of compressor driver (hp) [98.236(p)(1)(xiii)]4000
Compressor had scheduled depressurized shutdown during reporting year? [98.236(p)(1)(xiv)]Yes
Unique name or ID for reciprocating compressor [98.236(p)(1)(i)]RECIP_Compressor ENG 1200
Total time in operating-mode (hours) [98.236(p)(1)(ii)]4288
Total time in standby-pressurized-mode (hours) [98.236(p)(1)(iii)]0
Total time in not-operating-depressurized-mode (hours) [98.236(p)(1)(iv)]4496
Compressor measured in operating-mode? [98.236(p)(1)(v)]No
Compressor measured in standby-pressurized-mode? [98.236(p)(1)(vi)]No
Compressor measured in not-operating-depressurized-mode? [98.236(p)(1)(vii)]No
Compressor had blind flanges installed? [98.236(p)(1)(xii)]No
Power output of compressor driver (hp) [98.236(p)(1)(xiii)]4000
Compressor had scheduled depressurized shutdown during reporting year? [98.236(p)(1)(xiv)]Yes
Unique name or ID for reciprocating compressor [98.236(p)(1)(i)]RECIP_Compressor ENG 1300
Total time in operating-mode (hours) [98.236(p)(1)(ii)]4903
Total time in standby-pressurized-mode (hours) [98.236(p)(1)(iii)]0
Total time in not-operating-depressurized-mode (hours) [98.236(p)(1)(iv)]3881
Compressor measured in operating-mode? [98.236(p)(1)(v)]Yes
Compressor measured in standby-pressurized-mode? [98.236(p)(1)(vi)]No
Compressor measured in not-operating-depressurized-mode? [98.236(p)(1)(vii)]No
Compressor had blind flanges installed? [98.236(p)(1)(xii)]No
Power output of compressor driver (hp) [98.236(p)(1)(xiii)]4000
Compressor had scheduled depressurized shutdown during reporting year? [98.236(p)(1)(xiv)]Yes


ReciprocatingCompressorSourceRowDetails:
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]RECIP_Compressor ENG 1100
Reciprocating compressor source [98.236(p)(2)(i)(B)]Blowdown valve
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Compressor ENG 1100.Blowdown valve
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]RECIP_Compressor ENG 1100
Reciprocating compressor source [98.236(p)(2)(i)(B)]Isolation valve
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Compressor ENG 1100.Isolation valve
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]RECIP_Compressor ENG 1100
Reciprocating compressor source [98.236(p)(2)(i)(B)]Rod packing
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Compressor ENG 1100.Rod packing
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]RECIP_Compressor ENG 1200
Reciprocating compressor source [98.236(p)(2)(i)(B)]Blowdown valve
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Compressor ENG 1200.Blowdown valve
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]RECIP_Compressor ENG 1200
Reciprocating compressor source [98.236(p)(2)(i)(B)]Isolation valve
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Compressor ENG 1200.Isolation valve
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]RECIP_Compressor ENG 1200
Reciprocating compressor source [98.236(p)(2)(i)(B)]Rod packing
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Compressor ENG 1200.Rod packing
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]RECIP_Compressor ENG 1300
Reciprocating compressor source [98.236(p)(2)(i)(B)]Blowdown valve
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Compressor ENG 1300.Blowdown valve
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]RECIP_Compressor ENG 1300
Reciprocating compressor source [98.236(p)(2)(i)(B)]Isolation valve
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Compressor ENG 1300.Isolation valve
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]RECIP_Compressor ENG 1300
Reciprocating compressor source [98.236(p)(2)(i)(B)]Rod packing
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Compressor ENG 1300.Rod packing


ReciprocatingCompressorsLeakOrVentSampleDataRowDetails:
Unique Name or ID for leak or vent (Specify) [98.236(p)(2)(i)(C)] [98.236(p)(3)(i)(A)]RECIP_Compressor ENG 1300.Rod packing
Measurement date (mm/dd/yyyy) [98.236(p)(3)(i)(B)]2020-09-01
Measurement method [98.236(p)(3)(i)(C)]High volume sampler
Measured flow rate (standard cubic feet/hour) [98.236(p)(3)(i)(D)]140.94
Is the measurement location prior to or after commingling with non-compressor emission sources? [98.236(p)(3)(i)(F)]Not manifolded
Compressors in “Operating mode”RECIP_Compressor ENG 1300


ReciprocatingCompressorsEmissionFactorsSampleDataRowDetails:
Compressor Mode [98.236(p)(3)(ii)(A)]Operating
Compressor Source [98.236(p)(3)(ii)(A)]Blowdown valve
Compressor mode-source combination reporter emission factor, EFs,m (standard cubic feet per hour) [98.236(p)(3)(ii)(B)]10.90454369
Total number of compressors measured in the compressor mode-source combination in current reporting year and preceding two reporting years, Countm [98.236(p)(3)(ii)(C)]412
Is the reporter emission factor facility-specific or based on all of the reporter's applicable facilities? [98.236(p)(3)(ii)(D)]All applicable facilities
Compressor Mode [98.236(p)(3)(ii)(A)]Operating
Compressor Source [98.236(p)(3)(ii)(A)]Rod packing
Compressor mode-source combination reporter emission factor, EFs,m (standard cubic feet per hour) [98.236(p)(3)(ii)(B)]81.92604592
Total number of compressors measured in the compressor mode-source combination in current reporting year and preceding two reporting years, Countm [98.236(p)(3)(ii)(C)]588
Is the reporter emission factor facility-specific or based on all of the reporter's applicable facilities? [98.236(p)(3)(ii)(D)]All applicable facilities
Compressor Mode [98.236(p)(3)(ii)(A)]Standby-pressurized
Compressor Source [98.236(p)(3)(ii)(A)]Blowdown valve
Compressor mode-source combination reporter emission factor, EFs,m (standard cubic feet per hour) [98.236(p)(3)(ii)(B)]9.45780303
Total number of compressors measured in the compressor mode-source combination in current reporting year and preceding two reporting years, Countm [98.236(p)(3)(ii)(C)]132
Is the reporter emission factor facility-specific or based on all of the reporter's applicable facilities? [98.236(p)(3)(ii)(D)]All applicable facilities
Compressor Mode [98.236(p)(3)(ii)(A)]Not-operating-depressurized
Compressor Source [98.236(p)(3)(ii)(A)]Isolation valve
Compressor mode-source combination reporter emission factor, EFs,m (standard cubic feet per hour) [98.236(p)(3)(ii)(B)]96.14192818
Total number of compressors measured in the compressor mode-source combination in current reporting year and preceding two reporting years, Countm [98.236(p)(3)(ii)(C)]181
Is the reporter emission factor facility-specific or based on all of the reporter's applicable facilities? [98.236(p)(3)(ii)(D)]All applicable facilities


ReciprocatingCompressorsLeakOrVentDataRowDetails:
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Compressor ENG 1100.Blowdown valve
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Flare
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]No
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
Percentage of time the device was operational when compressor source emissions were routed to device [98.236(p)(2)(ii)(E)]100
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Compressor ENG 1100.Isolation valve
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Flare
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]No
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
Percentage of time the device was operational when compressor source emissions were routed to device [98.236(p)(2)(ii)(E)]100
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Compressor ENG 1100.Rod packing
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]No
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)]0.000463207733554486
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)]5.47254399125665
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Compressor ENG 1200.Blowdown valve
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Flare
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]No
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
Percentage of time the device was operational when compressor source emissions were routed to device [98.236(p)(2)(ii)(E)]100
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Compressor ENG 1200.Isolation valve
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Flare
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]No
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
Percentage of time the device was operational when compressor source emissions were routed to device [98.236(p)(2)(ii)(E)]100
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Compressor ENG 1200.Rod packing
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]No
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)]0.000554349640380027
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)]6.54933537106015
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Compressor ENG 1300.Blowdown valve
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Flare
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]No
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
Percentage of time the device was operational when compressor source emissions were routed to device [98.236(p)(2)(ii)(E)]100
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Compressor ENG 1300.Isolation valve
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Flare
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]No
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
Percentage of time the device was operational when compressor source emissions were routed to device [98.236(p)(2)(ii)(E)]100
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Compressor ENG 1300.Rod packing
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]Yes
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)]0.00109044347796
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)]12.882988497024


OtherEmissionsFromEquipmentLeaksDetails:
mt CO21.2938722366896
mt CH410.1020624740864
Did this facility use leak surveys to calculate emissions from equipment leaks in accordance with 98.232 [per 98.236(q)]?Yes
Were missing data procedures used for any parameters to calculate GHG emissions? [98.235]No
Number of complete equipment leak surveys performed during the calendar year [98.236(q)(1)(i)]1
Optical gas imaging instrument as specified in §60.18 [98.234(a)(1)]Yes
Method 21 [98.234(a)(2)]No
Infrared laser beam illuminated instrument [98.234(a)(3)]No
Acoustic leak detection device [98.234(a)(5)]No
Optical gas imaging instrument as specified in §60.5397a [98.234(a)(6)]No
Method 21 as specified in §60.5397a [98.234(a)(7)]No


GasProcessingEmissionsFactorsRowDetails:
Component Type [98.236(q)(2)(i)]Compressor Components, Gas Service - Connector
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)]1
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)]8784
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)]0.09161172644832
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)]0.71526952793088
Component Type [98.236(q)(2)(i)]Compressor Components, Gas Service - Meter
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)]0
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)]8784
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)]0
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)]0
Component Type [98.236(q)(2)(i)]Compressor Components, Gas Service - Open-ended Line
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)]0
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)]8784
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)]0
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)]0
Component Type [98.236(q)(2)(i)]Compressor Components, Gas Service - Pressure Relief Valve
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)]0
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)]8784
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)]0
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)]0
Component Type [98.236(q)(2)(i)]Compressor Components, Gas Service - Valve
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)]1
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)]8784
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)]0.24320537039232
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)]1.89885506162688
Component Type [98.236(q)(2)(i)]Non-Compressor Components, Gas Service - Connector
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)]8
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)]8784
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)]0.74862677355264
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)]5.84499320856576
Component Type [98.236(q)(2)(i)]Non-Compressor components, Gas Service - Meter
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)]0
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)]8784
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)]0
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)]0
Component Type [98.236(q)(2)(i)]Non-Compressor Components, Gas Service - Open-ended Line
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)]0
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)]8784
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)]0
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)]0
Component Type [98.236(q)(2)(i)]Non-Compressor components, Gas Service - Pressure Relief Valve
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)]0
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)]8784
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)]0
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)]0
Component Type [98.236(q)(2)(i)]Non-Compressor Components, Gas Service - Valve
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)]2
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)]8784
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)]0.21042836629632
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)]1.64294467596288