Source Reporting Form | Onshore Production [98.236(aa)(1)] |
Required for Selected Industry Segment | No |
Source Reporting Form | Facility Overview [98.236(aa)(2-11)] |
Required for Selected Industry Segment | Yes |
Source Reporting Form | Natural Gas Pneumatic Devices [98.236(b)] |
Required for Selected Industry Segment | Yes |
Total Reported CO2 Emissions (mt CO2) | 0.2 |
Total Reported CH4 Emissions (mt CH4) | 31.75 |
Source Reporting Form | Natural Gas Driven Pneumatic Pumps [98.236(c)] |
Required for Selected Industry Segment | No |
Total Reported CO2 Emissions (mt CO2) | 0.0 |
Total Reported CH4 Emissions (mt CH4) | 0.00 |
Source Reporting Form | Acid Gas Removal Units [98.236(d)] |
Required for Selected Industry Segment | No |
Total Reported CO2 Emissions (mt CO2) | 0.0 |
Source Reporting Form | Dehydrators [98.236(e)] |
Required for Selected Industry Segment | No |
Total Reported CO2 Emissions (mt CO2) | 0.0 |
Total Reported CH4 Emissions (mt CH4) | 0.00 |
Total Reported N2O Emissions (mt N2O) | 0.000 |
Source Reporting Form | Well Venting for Liquids Unloading [98.236(f)] |
Required for Selected Industry Segment | No |
Total Reported CO2 Emissions (mt CO2) | 0.0 |
Total Reported CH4 Emissions (mt CH4) | 0.00 |
Source Reporting Form | Completions and Workovers with Hydraulic Fracturing [98.236(g)] |
Required for Selected Industry Segment | No |
Total Reported CO2 Emissions (mt CO2) | 0.0 |
Total Reported CH4 Emissions (mt CH4) | 0.00 |
Total Reported N2O Emissions (mt N2O) | 0.000 |
Source Reporting Form | Completions and Workovers without Hydraulic Fracturing [98.236(h)] |
Required for Selected Industry Segment | No |
Total Reported CO2 Emissions (mt CO2) | 0.0 |
Total Reported CH4 Emissions (mt CH4) | 0.00 |
Total Reported N2O Emissions (mt N2O) | 0.000 |
Source Reporting Form | Blowdown Vent Stacks [98.236(i)] |
Required for Selected Industry Segment | Yes |
Total Reported CO2 Emissions (mt CO2) | 1.1 |
Total Reported CH4 Emissions (mt CH4) | 146.11 |
Source Reporting Form | Atmospheric Storage Tanks [98.236(j)] |
Required for Selected Industry Segment | No |
Total Reported CO2 Emissions (mt CO2) | 0.0 |
Total Reported CH4 Emissions (mt CH4) | 0.00 |
Total Reported N2O Emissions (mt N2O) | 0.000 |
Source Reporting Form | Transmission Storage Tanks [98.236(k)] |
Required for Selected Industry Segment | Yes |
Total Reported CO2 Emissions (mt CO2) | 0.0 |
Total Reported CH4 Emissions (mt CH4) | 0.00 |
Total Reported N2O Emissions (mt N2O) | 0.000 |
Source Reporting Form | Well Testing [98.236(l)] |
Required for Selected Industry Segment | No |
Total Reported CO2 Emissions (mt CO2) | 0.0 |
Total Reported CH4 Emissions (mt CH4) | 0.00 |
Total Reported N2O Emissions (mt N2O) | 0.000 |
Source Reporting Form | Associated Gas Venting and Flaring [98.236(m)] |
Required for Selected Industry Segment | No |
Total Reported CO2 Emissions (mt CO2) | 0.0 |
Total Reported CH4 Emissions (mt CH4) | 0.00 |
Total Reported N2O Emissions (mt N2O) | 0.000 |
Source Reporting Form | Flare Stacks [98.236(n)] |
Required for Selected Industry Segment | Yes |
Total Reported CO2 Emissions (mt CO2) | 0.0 |
Total Reported CH4 Emissions (mt CH4) | 0.00 |
Total Reported N2O Emissions (mt N2O) | 0.000 |
Source Reporting Form | Centrifugal Compressors [98.236(o)] |
Required for Selected Industry Segment | Yes |
Total Reported CO2 Emissions (mt CO2) | 0.0 |
Total Reported CH4 Emissions (mt CH4) | 6.48 |
Source Reporting Form | Reciprocating Compressors [98.236(p)] |
Required for Selected Industry Segment | Yes |
Total Reported CO2 Emissions (mt CO2) | 0.3 |
Total Reported CH4 Emissions (mt CH4) | 34.48 |
Source Reporting Form | Equipment Leaks Surveys and Population Counts [98.236(q,r)] |
Required for Selected Industry Segment | Yes |
Total Reported CO2 Emissions (mt CO2) | 0.7 |
Total Reported CH4 Emissions (mt CH4) | 21.47 |
Source Reporting Form | Offshore Petroleum and Natural Gas Production [98.236(s)] |
Required for Selected Industry Segment | No |
Total Reported CO2 Emissions (mt CO2) | 0.0 |
Total Reported CH4 Emissions (mt CH4) | 0.00 |
Total Reported N2O Emissions (mt N2O) | 0.000 |
Source Reporting Form | Enhanced Oil Recovery Injection Pumps [98.236(w)] |
Required for Selected Industry Segment | No |
Total Reported CO2 Emissions (mt CO2) | 0.0 |
Source Reporting Form | Enhanced Oil Recovery Hydrocarbon Liquids [98.236(x)] |
Required for Selected Industry Segment | No |
Total Reported CO2 Emissions (mt CO2) | 0.0 |
Source Reporting Form | Combustion Equipment at Onshore Petroleum and Natural Gas Production Facilities, Onshore Petroleum and Natural Gas Gathering and Boosting Facilities, and Natural gas Distribution Facilities [98.236(z)] |
Required for Selected Industry Segment | No |
Total Reported CO2 Emissions (mt CO2) | 0.0 |
Total Reported CH4 Emissions (mt CH4) | 0.00 |
Total Reported N2O Emissions (mt N2O) | 0.000 |
Unique name or ID for reciprocating compressor [98.236(p)(1)(i)] | Unit 201 |
Total time in operating-mode (hours) [98.236(p)(1)(ii)] | 1613.251 |
Total time in standby-pressurized-mode (hours) [98.236(p)(1)(iii)] | 7170.75 |
Total time in not-operating-depressurized-mode (hours) [98.236(p)(1)(iv)] | 0 |
Compressor measured in operating-mode? [98.236(p)(1)(v)] | No |
Compressor measured in standby-pressurized-mode? [98.236(p)(1)(vi)] | Yes |
Compressor measured in not-operating-depressurized-mode? [98.236(p)(1)(vii)] | No |
Compressor had blind flanges installed? [98.236(p)(1)(xii)] | No |
Power output of compressor driver (hp) [98.236(p)(1)(xiii)] | 2000 |
Compressor had scheduled depressurized shutdown during reporting year? [98.236(p)(1)(xiv)] | No |
Unique name or ID for reciprocating compressor [98.236(p)(1)(i)] | Unit 202 |
Total time in operating-mode (hours) [98.236(p)(1)(ii)] | 1892.918 |
Total time in standby-pressurized-mode (hours) [98.236(p)(1)(iii)] | 6891.08 |
Total time in not-operating-depressurized-mode (hours) [98.236(p)(1)(iv)] | 0.002 |
Compressor measured in operating-mode? [98.236(p)(1)(v)] | No |
Compressor measured in standby-pressurized-mode? [98.236(p)(1)(vi)] | Yes |
Compressor measured in not-operating-depressurized-mode? [98.236(p)(1)(vii)] | No |
Compressor had blind flanges installed? [98.236(p)(1)(xii)] | No |
Power output of compressor driver (hp) [98.236(p)(1)(xiii)] | 2000 |
Compressor had scheduled depressurized shutdown during reporting year? [98.236(p)(1)(xiv)] | No |
Unique name or ID for reciprocating compressor [98.236(p)(1)(i)] | Unit 203 |
Total time in operating-mode (hours) [98.236(p)(1)(ii)] | 1324.249 |
Total time in standby-pressurized-mode (hours) [98.236(p)(1)(iii)] | 7459.751 |
Total time in not-operating-depressurized-mode (hours) [98.236(p)(1)(iv)] | 0 |
Compressor measured in operating-mode? [98.236(p)(1)(v)] | No |
Compressor measured in standby-pressurized-mode? [98.236(p)(1)(vi)] | No |
Compressor measured in not-operating-depressurized-mode? [98.236(p)(1)(vii)] | Yes |
Compressor had blind flanges installed? [98.236(p)(1)(xii)] | No |
Power output of compressor driver (hp) [98.236(p)(1)(xiii)] | 2000 |
Compressor had scheduled depressurized shutdown during reporting year? [98.236(p)(1)(xiv)] | No |
Unique name or ID for reciprocating compressor [98.236(p)(1)(i)] | Unit 204 |
Total time in operating-mode (hours) [98.236(p)(1)(ii)] | 1465.166 |
Total time in standby-pressurized-mode (hours) [98.236(p)(1)(iii)] | 7318.834 |
Total time in not-operating-depressurized-mode (hours) [98.236(p)(1)(iv)] | 0 |
Compressor measured in operating-mode? [98.236(p)(1)(v)] | No |
Compressor measured in standby-pressurized-mode? [98.236(p)(1)(vi)] | No |
Compressor measured in not-operating-depressurized-mode? [98.236(p)(1)(vii)] | Yes |
Compressor had blind flanges installed? [98.236(p)(1)(xii)] | No |
Power output of compressor driver (hp) [98.236(p)(1)(xiii)] | 2000 |
Compressor had scheduled depressurized shutdown during reporting year? [98.236(p)(1)(xiv)] | No |
Unique name or ID for reciprocating compressor [98.236(p)(1)(i)] | Unit 205 |
Total time in operating-mode (hours) [98.236(p)(1)(ii)] | 807.834 |
Total time in standby-pressurized-mode (hours) [98.236(p)(1)(iii)] | 7976.166 |
Total time in not-operating-depressurized-mode (hours) [98.236(p)(1)(iv)] | 0 |
Compressor measured in operating-mode? [98.236(p)(1)(v)] | No |
Compressor measured in standby-pressurized-mode? [98.236(p)(1)(vi)] | Yes |
Compressor measured in not-operating-depressurized-mode? [98.236(p)(1)(vii)] | No |
Compressor had blind flanges installed? [98.236(p)(1)(xii)] | No |
Power output of compressor driver (hp) [98.236(p)(1)(xiii)] | 2000 |
Compressor had scheduled depressurized shutdown during reporting year? [98.236(p)(1)(xiv)] | No |
Unique name or ID for reciprocating compressor [98.236(p)(1)(i)] | Unit 206 |
Total time in operating-mode (hours) [98.236(p)(1)(ii)] | 3228.249 |
Total time in standby-pressurized-mode (hours) [98.236(p)(1)(iii)] | 5555.75 |
Total time in not-operating-depressurized-mode (hours) [98.236(p)(1)(iv)] | 0.001 |
Compressor measured in operating-mode? [98.236(p)(1)(v)] | No |
Compressor measured in standby-pressurized-mode? [98.236(p)(1)(vi)] | No |
Compressor measured in not-operating-depressurized-mode? [98.236(p)(1)(vii)] | Yes |
Compressor had blind flanges installed? [98.236(p)(1)(xii)] | No |
Power output of compressor driver (hp) [98.236(p)(1)(xiii)] | 2000 |
Compressor had scheduled depressurized shutdown during reporting year? [98.236(p)(1)(xiv)] | No |
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)] | Unit 201 |
Reciprocating compressor source [98.236(p)(2)(i)(B)] | Blowdown valve |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | Unit 201 BDV |
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)] | Unit 201 |
Reciprocating compressor source [98.236(p)(2)(i)(B)] | Isolation valve |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | Unit 201 ISV |
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)] | Unit 201 |
Reciprocating compressor source [98.236(p)(2)(i)(B)] | Rod packing |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | Unit 201 RP |
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)] | Unit 202 |
Reciprocating compressor source [98.236(p)(2)(i)(B)] | Blowdown valve |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | Unit 202 BDV |
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)] | Unit 202 |
Reciprocating compressor source [98.236(p)(2)(i)(B)] | Isolation valve |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | Unit 202 ISV |
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)] | Unit 202 |
Reciprocating compressor source [98.236(p)(2)(i)(B)] | Rod packing |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | Unit 202 RP |
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)] | Unit 203 |
Reciprocating compressor source [98.236(p)(2)(i)(B)] | Blowdown valve |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | Unit 203 BDV |
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)] | Unit 203 |
Reciprocating compressor source [98.236(p)(2)(i)(B)] | Isolation valve |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | Unit 203 ISV |
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)] | Unit 203 |
Reciprocating compressor source [98.236(p)(2)(i)(B)] | Rod packing |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | Unit 203 RP |
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)] | Unit 204 |
Reciprocating compressor source [98.236(p)(2)(i)(B)] | Blowdown valve |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | Unit 204 BDV |
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)] | Unit 204 |
Reciprocating compressor source [98.236(p)(2)(i)(B)] | Isolation valve |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | Unit 204 ISV |
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)] | Unit 204 |
Reciprocating compressor source [98.236(p)(2)(i)(B)] | Rod packing |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | Unit 204 RP |
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)] | Unit 205 |
Reciprocating compressor source [98.236(p)(2)(i)(B)] | Blowdown valve |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | Unit 205 BDV |
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)] | Unit 205 |
Reciprocating compressor source [98.236(p)(2)(i)(B)] | Isolation valve |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | Unit 205 ISV |
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)] | Unit 205 |
Reciprocating compressor source [98.236(p)(2)(i)(B)] | Rod packing |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | Unit 205 RP |
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)] | Unit 206 |
Reciprocating compressor source [98.236(p)(2)(i)(B)] | Blowdown valve |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | Unit 206 BDV |
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)] | Unit 206 |
Reciprocating compressor source [98.236(p)(2)(i)(B)] | Isolation valve |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | Unit 206 ISV |
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)] | Unit 206 |
Reciprocating compressor source [98.236(p)(2)(i)(B)] | Rod packing |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | Unit 206 RP |
Unique Name or ID for leak or vent (Specify) [98.236(p)(2)(i)(C)] [98.236(p)(3)(i)(A)] | Unit 201 BDV |
Measurement date (mm/dd/yyyy) [98.236(p)(3)(i)(B)] | 2020-06-04 |
Measurement method [98.236(p)(3)(i)(C)] | High volume sampler |
Measured flow rate (standard cubic feet/hour) [98.236(p)(3)(i)(D)] | 13.933 |
Is the measurement location prior to or after commingling with non-compressor emission sources? [98.236(p)(3)(i)(F)] | Prior to commingling |
Compressors in *Standby-pressurized mode* | Unit 201 |
Unique Name or ID for leak or vent (Specify) [98.236(p)(2)(i)(C)] [98.236(p)(3)(i)(A)] | Unit 202 BDV |
Measurement date (mm/dd/yyyy) [98.236(p)(3)(i)(B)] | 2020-06-04 |
Measurement method [98.236(p)(3)(i)(C)] | High volume sampler |
Measured flow rate (standard cubic feet/hour) [98.236(p)(3)(i)(D)] | 13.933 |
Is the measurement location prior to or after commingling with non-compressor emission sources? [98.236(p)(3)(i)(F)] | Prior to commingling |
Compressors in *Standby-pressurized mode* | Unit 202 |
Unique Name or ID for leak or vent (Specify) [98.236(p)(2)(i)(C)] [98.236(p)(3)(i)(A)] | Unit 203 ISV |
Measurement date (mm/dd/yyyy) [98.236(p)(3)(i)(B)] | 2020-06-04 |
Measurement method [98.236(p)(3)(i)(C)] | High volume sampler |
Measured flow rate (standard cubic feet/hour) [98.236(p)(3)(i)(D)] | 269.376 |
Is the measurement location prior to or after commingling with non-compressor emission sources? [98.236(p)(3)(i)(F)] | Not manifolded |
Compressors in “Not-operating mode” | Unit 203 |
Unique Name or ID for leak or vent (Specify) [98.236(p)(2)(i)(C)] [98.236(p)(3)(i)(A)] | Unit 204 ISV |
Measurement date (mm/dd/yyyy) [98.236(p)(3)(i)(B)] | 2020-06-04 |
Measurement method [98.236(p)(3)(i)(C)] | High volume sampler |
Measured flow rate (standard cubic feet/hour) [98.236(p)(3)(i)(D)] | 215.5 |
Is the measurement location prior to or after commingling with non-compressor emission sources? [98.236(p)(3)(i)(F)] | Not manifolded |
Compressors in “Not-operating mode” | Unit 204 |
Unique Name or ID for leak or vent (Specify) [98.236(p)(2)(i)(C)] [98.236(p)(3)(i)(A)] | Unit 205 BDV |
Measurement date (mm/dd/yyyy) [98.236(p)(3)(i)(B)] | 2020-06-04 |
Measurement method [98.236(p)(3)(i)(C)] | High volume sampler |
Measured flow rate (standard cubic feet/hour) [98.236(p)(3)(i)(D)] | 90.101 |
Is the measurement location prior to or after commingling with non-compressor emission sources? [98.236(p)(3)(i)(F)] | Prior to commingling |
Compressors in *Standby-pressurized mode* | Unit 205 |
Unique Name or ID for leak or vent (Specify) [98.236(p)(2)(i)(C)] [98.236(p)(3)(i)(A)] | Unit 206 ISV |
Measurement date (mm/dd/yyyy) [98.236(p)(3)(i)(B)] | 2020-06-04 |
Measurement method [98.236(p)(3)(i)(C)] | Screening/Optical gas imaging |
Measured flow rate (standard cubic feet/hour) [98.236(p)(3)(i)(D)] | 0 |
Is the measurement location prior to or after commingling with non-compressor emission sources? [98.236(p)(3)(i)(F)] | Not manifolded |
Compressors in “Not-operating mode” | Unit 206 |
Compressor Mode [98.236(p)(3)(ii)(A)] | Operating |
Compressor Source [98.236(p)(3)(ii)(A)] | Blowdown valve |
Compressor mode-source combination reporter emission factor, EFs,m (standard cubic feet per hour) [98.236(p)(3)(ii)(B)] | 31.63 |
Total number of compressors measured in the compressor mode-source combination in current reporting year and preceding two reporting years, Countm [98.236(p)(3)(ii)(C)] | 288 |
Is the reporter emission factor facility-specific or based on all of the reporter's applicable facilities? [98.236(p)(3)(ii)(D)] | All applicable facilities |
Compressor Mode [98.236(p)(3)(ii)(A)] | Operating |
Compressor Source [98.236(p)(3)(ii)(A)] | Rod packing |
Compressor mode-source combination reporter emission factor, EFs,m (standard cubic feet per hour) [98.236(p)(3)(ii)(B)] | 110.99 |
Total number of compressors measured in the compressor mode-source combination in current reporting year and preceding two reporting years, Countm [98.236(p)(3)(ii)(C)] | 288 |
Is the reporter emission factor facility-specific or based on all of the reporter's applicable facilities? [98.236(p)(3)(ii)(D)] | All applicable facilities |
Compressor Mode [98.236(p)(3)(ii)(A)] | Standby-pressurized |
Compressor Source [98.236(p)(3)(ii)(A)] | Blowdown valve |
Compressor mode-source combination reporter emission factor, EFs,m (standard cubic feet per hour) [98.236(p)(3)(ii)(B)] | 15.61 |
Total number of compressors measured in the compressor mode-source combination in current reporting year and preceding two reporting years, Countm [98.236(p)(3)(ii)(C)] | 257 |
Is the reporter emission factor facility-specific or based on all of the reporter's applicable facilities? [98.236(p)(3)(ii)(D)] | All applicable facilities |
Compressor Mode [98.236(p)(3)(ii)(A)] | Not-operating-depressurized |
Compressor Source [98.236(p)(3)(ii)(A)] | Isolation valve |
Compressor mode-source combination reporter emission factor, EFs,m (standard cubic feet per hour) [98.236(p)(3)(ii)(B)] | 118.39 |
Total number of compressors measured in the compressor mode-source combination in current reporting year and preceding two reporting years, Countm [98.236(p)(3)(ii)(C)] | 839 |
Is the reporter emission factor facility-specific or based on all of the reporter's applicable facilities? [98.236(p)(3)(ii)(D)] | All applicable facilities |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | Unit 201 BDV |
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)] | Single |
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)] | Atmosphere |
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)] | Yes |
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)] | No |
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)] | 0.041 |
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)] | 2.397 |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | Unit 201 ISV |
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)] | Single |
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)] | Atmosphere |
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)] | No |
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)] | No |
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)] | 0 |
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)] | 0 |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | Unit 201 RP |
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)] | Single |
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)] | Atmosphere |
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)] | No |
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)] | No |
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)] | 0.023 |
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)] | 3.168 |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | Unit 202 BDV |
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)] | Single |
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)] | Atmosphere |
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)] | Yes |
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)] | No |
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)] | 0.008 |
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)] | 1.059 |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | Unit 202 ISV |
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)] | Single |
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)] | Atmosphere |
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)] | No |
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)] | No |
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)] | 0 |
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)] | 0 |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | Unit 202 RP |
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)] | Single |
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)] | Atmosphere |
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)] | No |
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)] | No |
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)] | 0.027 |
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)] | 3.718 |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | Unit 203 BDV |
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)] | Single |
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)] | Atmosphere |
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)] | No |
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)] | No |
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)] | 0.02 |
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)] | 2.801 |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | Unit 203 ISV |
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)] | Single |
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)] | Atmosphere |
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)] | Yes |
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)] | No |
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)] | 0 |
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)] | 0.00043 |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | Unit 203 RP |
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)] | Single |
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)] | Atmosphere |
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)] | No |
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)] | No |
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)] | 0.019 |
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)] | 2.601 |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | Unit 204 BDV |
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)] | Single |
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)] | Atmosphere |
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)] | No |
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)] | No |
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)] | 0.021 |
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)] | 2.841 |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | Unit 204 ISV |
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)] | Single |
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)] | Atmosphere |
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)] | Yes |
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)] | No |
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)] | 0 |
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)] | 0.00043 |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | Unit 204 RP |
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)] | Single |
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)] | Atmosphere |
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)] | No |
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)] | No |
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)] | 0.021 |
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)] | 2.877 |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | Unit 205 BDV |
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)] | Single |
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)] | Atmosphere |
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)] | Yes |
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)] | No |
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)] | 0.024 |
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)] | 3.28 |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | Unit 205 ISV |
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)] | Single |
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)] | Atmosphere |
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)] | No |
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)] | No |
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)] | 0 |
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)] | 0.00043 |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | Unit 205 RP |
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)] | Single |
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)] | Atmosphere |
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)] | No |
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)] | No |
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)] | 0.012 |
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)] | 1.587 |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | Unit 206 BDV |
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)] | Single |
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)] | Atmosphere |
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)] | No |
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)] | No |
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)] | 0.013 |
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)] | 1.806 |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | Unit 206 ISV |
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)] | Single |
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)] | Atmosphere |
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)] | Yes |
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)] | No |
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)] | 0 |
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)] | 0 |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | Unit 206 RP |
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)] | Single |
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)] | Atmosphere |
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)] | No |
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)] | No |
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)] | 0.046 |
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)] | 6.34 |
Component Type [98.236(q)(2)(i)] | Compressor Components, Gas Service - Valve |
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)] | 5 |
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)] | 8784 |
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)] | 0.377 |
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)] | 12.201 |
Component Type [98.236(q)(2)(i)] | Compressor Components, Gas Service - Connector |
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)] | 0 |
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)] | 8784 |
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)] | 0 |
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)] | 0 |
Component Type [98.236(q)(2)(i)] | Compressor Components, Gas Service - Open-ended Line |
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)] | 0 |
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)] | 8784 |
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)] | 0 |
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)] | 0 |
Component Type [98.236(q)(2)(i)] | Compressor Components, Gas Service - Pressure Relief Valve |
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)] | 0 |
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)] | 8784 |
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)] | 0 |
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)] | 0 |
Component Type [98.236(q)(2)(i)] | Compressor Components, Gas Service - Meter or Instrument |
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)] | 0 |
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)] | 8784 |
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)] | 0 |
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)] | 0 |
Component Type [98.236(q)(2)(i)] | Compressor Components, Gas Service - Other |
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)] | 0 |
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)] | 8784 |
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)] | 0 |
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)] | 0 |
Component Type [98.236(q)(2)(i)] | Non-Compressor Components, Gas Service - Valve |
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)] | 7 |
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)] | 8784 |
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)] | 0.228 |
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)] | 7.39 |
Component Type [98.236(q)(2)(i)] | Non-Compressor Components, Gas Service - Connector |
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)] | 2 |
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)] | 8784 |
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)] | 0.058 |
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)] | 1.878 |
Component Type [98.236(q)(2)(i)] | Non-Compressor Components, Gas Service - Open-ended Line |
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)] | 0 |
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)] | 8784 |
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)] | 0 |
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)] | 0 |
Component Type [98.236(q)(2)(i)] | Non-Compressor components, Gas Service - Pressure Relief Valve |
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)] | 0 |
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)] | 8784 |
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)] | 0 |
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)] | 0 |
Component Type [98.236(q)(2)(i)] | Non-Compressor components, Gas Service - Meter or Instrument |
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)] | 0 |
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)] | 8784 |
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)] | 0 |
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)] | 0 |
Component Type [98.236(q)(2)(i)] | Non-Compressor components, Gas Service - Other |
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)] | 0 |
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)] | 8784 |
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)] | 0 |
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)] | 0 |