Facility Name:Zider
Facility Identifier:
Facility Reporting Year:2020
Facility Location:
Address: N 31 42'14.83
City: Aiken
State: TX
Postal Code: 75935

Facility Site Details:
CO2 equivalent emissions from facility subparts C-II, SS, and TT (metric tons):22,359.1
CO2 equivalent emissions from supplier subparts LL-QQ (metric tons):
Biogenic CO2 emissions from facility subparts C-II, SS, and TT (metric tons):0
Cogeneration Unit Emissions Indicator:N
GHG Report Start Date:2020-01-01
GHG Report End Date:2020-12-31
Description of Changes to Calculation Methodology:
Plant Code Indicator:N
Primary NAICS Code:486210
Second Primary NAICS Code:

Parent Company Details:
Parent Company Name:MIDCOAST ENERGY LLC
Address:1501 McKinney Street, Suite #600, Houston,  TX 77010
Percent Ownership Interest:100

Subpart C: General Stationary Fuel Combustion

Gas Information Details

Gas NameCarbon Dioxide
Gas Quantity7,511 (Metric Tons)
Own Result?

Gas NameBiogenic Carbon dioxide
Gas Quantity0 (Metric Tons)
Own Result?

Gas NameMethane
Gas Quantity0.14 (Metric Tons)
Own Result?

Gas NameNitrous Oxide
Gas Quantity0.014 (Metric Tons)
Own Result?

Unit Details:
Unit Name : GP-Zider
Unit Type : OCS (Other combustion source)
Unit Description :
Other Unit Name :
Small Unit Aggregation Details:
Use Ivt Indicator: Y
Highest Maximum Rated Heat Input Capacity: 8.5
Cumulative Maximum Rated Heat Input Capacity:

Emission Details:
Annual CO2 mass emissions from sorbent: 0 (Metric Tons)
Annual Biogenic CO2 Emissions: 0 (metric tons)
Annual Fossil fuel based CO2 Emissions: 0 (metric tons)

Tier Fuel Details:
Fuel : Natural Gas (Weighted U.S. Average)
Tier Name : Tier 2 (Equation C-2a)
Tier Methodology Start Date : 2020-01-01
Tier Methodology End Date : 2020-12-31
Frequency of HHV determinations : Monthly

Tier 2 Monthly HHV Details :
JanuaryFebruaryMarchAprilMayJuneJulyAugustSeptemberOctoberNovemberDecember
N N N N N N N N N N N N

Fuel Emission Details :
Total CO2 emissionsTotal CH4 emissionsTotal N2O emissionsTotal CH4 emissions CO2eTotal N2O emissions CO2e
7511.0 (Metric Tons) 0.14 (Metric Tons) 0.014 (Metric Tons) 3.5 (Metric Tons) 4.2 (Metric Tons)



Subpart W: Petroleum and Natural Gas Systems

Gas Information Details

Gas NameCarbon Dioxide
Gas Quantity14,839.2 (Metric Tons)
Own Result?

Gas NameMethane
Gas Quantity0.05 (Metric Tons)
Own Result?

Gas NameNitrous Oxide
Gas Quantity0 (Metric Tons)
Own Result?


SubpartWSummaryDetails:
Industry Segment Number3
Industry Segment NameOnshore natural gas processing [98.230(a)(3)]
Total Reported CO2 Emissions (mt CO2)14839.2
Total CO2e Emissions (mt CO2e)14840.4
Total Reported CH4 Emissions (mt CH4)0.05
Total Reported N2O Emissions (mt N2O)0.000


SubpartWSourceReportingFormRowDetails:
Source Reporting FormOnshore Production [98.236(aa)(1)]
Required for Selected Industry SegmentNo
Source Reporting FormFacility Overview [98.236(aa)(2-11)]
Required for Selected Industry SegmentYes
Source Reporting FormNatural Gas Pneumatic Devices [98.236(b)]
Required for Selected Industry SegmentNo
Total Reported CO2 Emissions (mt CO2)0.0
Total Reported CH4 Emissions (mt CH4)0.00
Source Reporting FormNatural Gas Driven Pneumatic Pumps [98.236(c)]
Required for Selected Industry SegmentNo
Total Reported CO2 Emissions (mt CO2)0.0
Total Reported CH4 Emissions (mt CH4)0.00
Source Reporting FormAcid Gas Removal Units [98.236(d)]
Required for Selected Industry SegmentYes
Total Reported CO2 Emissions (mt CO2)14823.3
Source Reporting FormDehydrators [98.236(e)]
Required for Selected Industry SegmentYes
Total Reported CO2 Emissions (mt CO2)15.9
Total Reported CH4 Emissions (mt CH4)0.05
Total Reported N2O Emissions (mt N2O)0.000
Source Reporting FormWell Venting for Liquids Unloading [98.236(f)]
Required for Selected Industry SegmentNo
Total Reported CO2 Emissions (mt CO2)0.0
Total Reported CH4 Emissions (mt CH4)0.00
Source Reporting FormCompletions and Workovers with Hydraulic Fracturing [98.236(g)]
Required for Selected Industry SegmentNo
Total Reported CO2 Emissions (mt CO2)0.0
Total Reported CH4 Emissions (mt CH4)0.00
Total Reported N2O Emissions (mt N2O)0.000
Source Reporting FormCompletions and Workovers without Hydraulic Fracturing [98.236(h)]
Required for Selected Industry SegmentNo
Total Reported CO2 Emissions (mt CO2)0.0
Total Reported CH4 Emissions (mt CH4)0.00
Total Reported N2O Emissions (mt N2O)0.000
Source Reporting FormBlowdown Vent Stacks [98.236(i)]
Required for Selected Industry SegmentYes
Total Reported CO2 Emissions (mt CO2)0.0
Total Reported CH4 Emissions (mt CH4)0.00
Source Reporting FormAtmospheric Storage Tanks [98.236(j)]
Required for Selected Industry SegmentNo
Total Reported CO2 Emissions (mt CO2)0.0
Total Reported CH4 Emissions (mt CH4)0.00
Total Reported N2O Emissions (mt N2O)0.000
Source Reporting FormTransmission Storage Tanks [98.236(k)]
Required for Selected Industry SegmentNo
Total Reported CO2 Emissions (mt CO2)0.0
Total Reported CH4 Emissions (mt CH4)0.00
Total Reported N2O Emissions (mt N2O)0.000
Source Reporting FormWell Testing [98.236(l)]
Required for Selected Industry SegmentNo
Total Reported CO2 Emissions (mt CO2)0.0
Total Reported CH4 Emissions (mt CH4)0.00
Total Reported N2O Emissions (mt N2O)0.000
Source Reporting FormAssociated Gas Venting and Flaring [98.236(m)]
Required for Selected Industry SegmentNo
Total Reported CO2 Emissions (mt CO2)0.0
Total Reported CH4 Emissions (mt CH4)0.00
Total Reported N2O Emissions (mt N2O)0.000
Source Reporting FormFlare Stacks [98.236(n)]
Required for Selected Industry SegmentYes
Total Reported CO2 Emissions (mt CO2)0.0
Total Reported CH4 Emissions (mt CH4)0.00
Total Reported N2O Emissions (mt N2O)0.000
Source Reporting FormCentrifugal Compressors [98.236(o)]
Required for Selected Industry SegmentYes
Total Reported CO2 Emissions (mt CO2)0.0
Total Reported CH4 Emissions (mt CH4)0.00
Source Reporting FormReciprocating Compressors [98.236(p)]
Required for Selected Industry SegmentYes
Total Reported CO2 Emissions (mt CO2)0.0
Total Reported CH4 Emissions (mt CH4)0.00
Source Reporting FormEquipment Leaks Surveys and Population Counts [98.236(q,r)]
Required for Selected Industry SegmentYes
Total Reported CO2 Emissions (mt CO2)0.0
Total Reported CH4 Emissions (mt CH4)0.00
Source Reporting FormOffshore Petroleum and Natural Gas Production [98.236(s)]
Required for Selected Industry SegmentNo
Total Reported CO2 Emissions (mt CO2)0.0
Total Reported CH4 Emissions (mt CH4)0.00
Total Reported N2O Emissions (mt N2O)0.000
Source Reporting FormEnhanced Oil Recovery Injection Pumps [98.236(w)]
Required for Selected Industry SegmentNo
Total Reported CO2 Emissions (mt CO2)0.0
Source Reporting FormEnhanced Oil Recovery Hydrocarbon Liquids [98.236(x)]
Required for Selected Industry SegmentNo
Total Reported CO2 Emissions (mt CO2)0.0
Source Reporting FormCombustion Equipment at Onshore Petroleum and Natural Gas Production Facilities, Onshore Petroleum and Natural Gas Gathering and Boosting Facilities, and Natural gas Distribution Facilities [98.236(z)]
Required for Selected Industry SegmentNo
Total Reported CO2 Emissions (mt CO2)0.0
Total Reported CH4 Emissions (mt CH4)0.00
Total Reported N2O Emissions (mt N2O)0.000


FacilityOverviewDetails:


FacilityOverviewNaturalGasProcessingRowDetails:
Average mole fraction of CH4 in natural gas received [98.236(aa)(3)(v)]0.956
Average mole fraction of CO2 in natural gas received [98.236(aa)(3)(vi)]0.0399
Does the facility fractionate NGLs? [98.236(aa)(3)(vii)]No


AcidGasRemovalUnitsDetails:
mt CO214823.3
Did the Facility have any acid gas removal units that vent directly to the atmosphere, to a flare or engine, or to a sulfur recovery plant subject to reporting under 98.232 [98.236(d)]?Yes
Were missing data procedures used for any parameters to calculate GHG emissions? [98.235]No


AcidGasInfoRowDetails:
Unit ID or Name [98.236(d)(1)(i)]Amine Unit 1
Total feed rate entering the acid gas removal unit for the year (million cubic feet) [98.236(d)(1)(ii)]4104.253
Calculation Method Used (Select from list) [98.236(d)(1)(iii)]Calculation Methodology 3 [98.233(d)(3)]
Are any CO2 emissions from the acid gas removal unit recovered and transferred outside the facility? (Yes / No) [98.236(d)(1)(iv)]No
Total CO2 Emissions (mt CO2) [98.236(d)(1)(v)]6862.1593653
Unit ID or Name [98.236(d)(1)(i)]Amine Unit 2
Total feed rate entering the acid gas removal unit for the year (million cubic feet) [98.236(d)(1)(ii)]4509.905
Calculation Method Used (Select from list) [98.236(d)(1)(iii)]Calculation Methodology 3 [98.233(d)(3)]
Are any CO2 emissions from the acid gas removal unit recovered and transferred outside the facility? (Yes / No) [98.236(d)(1)(iv)]No
Total CO2 Emissions (mt CO2) [98.236(d)(1)(v)]7961.1735384


AcidGasCalcMethod3EmissionsRowDetails:
Unit ID or Name [98.236(d)(1)(i)]Amine Unit 1
Equation Used (W-4A/W-4B) [98.236(d)(2)(ii)(A)]W-4A
Annual average fraction of CO2 content of natural gas into the acid gas removal unit, Voli (volumetric fraction) [98.236(d)(2)(ii)(C)]0.0399
Annual average fraction of CO2 content of natural gas out of the acid gas removal unit, Volo (volumetric fraction) [98.236(d)(2)(ii)(B)]0.00838
Natural gas flow rate into the acid gas removal unit, Vin (actual or standard cubic feet) (Eq. W-4A) [98.236(d)(2)(ii)(D)]4104253000
Natural gas flow rate reported on an Actual or Standard basis? [98.236]Standard
Temperature used to calculate natural gas flow rate (°F) [98.236]60
Pressure used to calculate natural gas flow rate (psi) [98.236]14.7
Unit ID or Name [98.236(d)(1)(i)]Amine Unit 2
Equation Used (W-4A/W-4B) [98.236(d)(2)(ii)(A)]W-4A
Annual average fraction of CO2 content of natural gas into the acid gas removal unit, Voli (volumetric fraction) [98.236(d)(2)(ii)(C)]0.0399
Annual average fraction of CO2 content of natural gas out of the acid gas removal unit, Volo (volumetric fraction) [98.236(d)(2)(ii)(B)]0.00656
Natural gas flow rate into the acid gas removal unit, Vin (actual or standard cubic feet) (Eq. W-4A) [98.236(d)(2)(ii)(D)]4509905000
Natural gas flow rate reported on an Actual or Standard basis? [98.236]Standard
Temperature used to calculate natural gas flow rate (°F) [98.236]60
Pressure used to calculate natural gas flow rate (psi) [98.236]14.7


DehydratorsDetails:
mt CO215.9
mt CH40.05
mt N2O0.000
Did the facility have any glycol dehydrators with annual average daily natural gas throughputs greater than or equal to 0.4MMscfd subject to reporting under 98.232 [98.236(e)]?Yes
Did the facility have any glycol dehydrators with annual average daily natural gas throughputs less than 0.4MMscfd subject to reporting under 98.232 [98.236(e)]?No
Did the facility have any desiccant dehydrators subject to reporting under 98.232 [98.236(e)]?No
Were missing data procedures used for any parameters to calculate GHG emissions? [98.235]No


SmallGlycolDehydrators:
Emissions vented to flare or regenerator firebox/fire tubes
Emissions that were not vented to a flare or regenerator firebox/fire tubes


DessicantDehydrators:
Emissions vented to flare or regenerator firebox/fire tubes
Emissions that were not vented to a flare or regenerator firebox/fire tubes


GlycolDehydratorsMoreThanSpecifiedValueRowDetails:
Unit ID or Name [98.236(e)(1)(i)]Zider Dehy 1
Glycol dehydrator feed natural gas flow rate determined by engineering estimate based on best available data (MMscfd) [98.236(e)(1)(ii)]24
Dehydrator feed natural gas water content (pounds per MMscf) [98.236(e)(1)(iii)]32.34
Dehydrator outlet natural gas water content (pounds per MMscf) [98.236(e)(1)(iv)]1.58
Glycol dehydrator absorbent circulation pump type [98.236(e)(1)(v)]Natural gas pneumatic
Dehydrator absorbent circulation rate (gallons per minute) [98.236(e)(1)(vi)]3
Report type of absorbent used [98.236(e)(1)(vii)]Triethylene glycol (TEG)
Report whether stripper gas is used in glycol dehydrator [98.236(e)(1)(viii)]No
Report whether a flash tank separator is used in glycol dehydrator [98.236(e)(1)(ix)]Yes
Total time the glycol dehydrator is operating (hours) [98.236(e)(1)(x)]4200
Temperature of the wet natural gas (°F) [98.236(e)(1)(xi)]79
Pressure of the wet natural gas (psig) [98.236(e)(1)(xii)]950
Concentration of CO2 in wet natural gas (mole fraction) [98.236(e)(1)(xiv)]0.0398
Concentration of CH4 in wet natural gas (mole fraction) [98.236(e)(1)(xiii)]0.95
Were any dehydrator emissions vented to a vapor recovery device? [98.236(e)(1)(xv)]Yes
Were any dehydrator emissions vented to a flare or regenerator firebox/fire tubes? [98.236(e)(1)(xvi)]Yes
CO2 Emissions from Flares or Regenerators (mt CO2) [98.236(e)(1)(xvi)(A)]8.2901702
CH4 Emissions from Flares or Regenerators (mt CH4) [98.236(e)(1)(xvi)(B)]0.0243197
N2O Emissions from Flares or Regenerators (mt N2O) [98.236(e)(1)(xvi)(C)]0.0000223
Were any dehydrator emissions vented to the atmosphere without being routed to a flare or regenerator firebox/fire tubes? [98.236(e)(1)(xvii)]No
Unit ID or Name [98.236(e)(1)(i)]Zider Dehy 2
Glycol dehydrator feed natural gas flow rate determined by engineering estimate based on best available data (MMscfd) [98.236(e)(1)(ii)]25
Dehydrator feed natural gas water content (pounds per MMscf) [98.236(e)(1)(iii)]44.17
Dehydrator outlet natural gas water content (pounds per MMscf) [98.236(e)(1)(iv)]2.6
Glycol dehydrator absorbent circulation pump type [98.236(e)(1)(v)]Natural gas pneumatic
Dehydrator absorbent circulation rate (gallons per minute) [98.236(e)(1)(vi)]3
Report type of absorbent used [98.236(e)(1)(vii)]Triethylene glycol (TEG)
Report whether stripper gas is used in glycol dehydrator [98.236(e)(1)(viii)]No
Report whether a flash tank separator is used in glycol dehydrator [98.236(e)(1)(ix)]Yes
Total time the glycol dehydrator is operating (hours) [98.236(e)(1)(x)]4300
Temperature of the wet natural gas (°F) [98.236(e)(1)(xi)]89
Pressure of the wet natural gas (psig) [98.236(e)(1)(xii)]950
Concentration of CO2 in wet natural gas (mole fraction) [98.236(e)(1)(xiv)]0.0398
Concentration of CH4 in wet natural gas (mole fraction) [98.236(e)(1)(xiii)]0.95
Were any dehydrator emissions vented to a vapor recovery device? [98.236(e)(1)(xv)]Yes
Were any dehydrator emissions vented to a flare or regenerator firebox/fire tubes? [98.236(e)(1)(xvi)]Yes
CO2 Emissions from Flares or Regenerators (mt CO2) [98.236(e)(1)(xvi)(A)]7.6030609
CH4 Emissions from Flares or Regenerators (mt CH4) [98.236(e)(1)(xvi)(B)]0.0233965
N2O Emissions from Flares or Regenerators (mt N2O) [98.236(e)(1)(xvi)(C)]0.0000205
Were any dehydrator emissions vented to the atmosphere without being routed to a flare or regenerator firebox/fire tubes? [98.236(e)(1)(xvii)]No


BlowdownVentStacksDetails:
mt CO20.0
mt CH40.00
Did the facility have any blowdown vent stacks subject to reporting under 98.232 [98.236(i)]?No


FlareStacksDetails:
mt CO20.0
mt CH40.00
mt N2O0.000
Did the facility have flare stacks subject to reporting under 98.232 [98.236(n)]?Yes
Were missing data procedures used for any parameters to calculate GHG emissions? [98.235]No


UniqueFlareStacksRowDetails:
Unique Name or ID Number for the Flare Stack [98.236(n)(1)]TO Am
Does the flare stack have a continuous flow monitor on gas to the flare? [98.236(n)(2)]No
Does the flare stack have a continuous gas analyzer on gas to the flare? [98.236(n)(3)]No
Were CEMS used to measure CO2 emissions for the flare stack? [98.233(n)(8)] [98.236(n)(12)]No
Volume of gas sent to flare, Vs (standard cubic feet) [98.236(n)(4)]281812412.6191947
Flare combustion efficiency (decimal value) [98.236(n)(6)]0.98
Mole fraction of CH4 in flare feed gas, XCH4 [98.236(n)(7)]0
Mole fraction of CO2 in flare feed gas, XCO2 [98.236(n)(8)]0
Fraction of feed gas sent to un-lit flare, Zu [98.236(n)(5)]0
CO2 emissions (mt CO2) [98.236(n)(9)]0
CH4 Emissions (mt CH4) (Eq. W-19) [98.236(n)(10)]0
N2O Emissions (mt N2O) (Eq. W-40) [98.236(n)(11)]0


CentrifugalCompressorsDetails:
mt CO20.0
mt CH40.00
Did the facility have any centrifugal compressors subject to reporting under 98.232 [98.236(o)]?No


ReciprocatingCompressorsDetails:
mt CO20.0
mt CH40.00
Did the facility have any reciprocating compressors subject to reporting under 98.232 [98.236(p)]?No


OtherEmissionsFromEquipmentLeaksDetails:
mt CO20.0
mt CH40.00
Did this facility use leak surveys to calculate emissions from equipment leaks in accordance with 98.232 [per 98.236(q)]?Yes
Were missing data procedures used for any parameters to calculate GHG emissions? [98.235]No
Number of complete equipment leak surveys performed during the calendar year [98.236(q)(1)(i)]1
Optical gas imaging instrument as specified in §60.18 [98.234(a)(1)]Yes
Method 21 [98.234(a)(2)]No
Infrared laser beam illuminated instrument [98.234(a)(3)]No
Acoustic leak detection device [98.234(a)(5)]No
Optical gas imaging instrument as specified in §60.5397a [98.234(a)(6)]Yes
Method 21 as specified in §60.5397a [98.234(a)(7)]No


GasProcessingEmissionsFactorsRowDetails:
Component Type [98.236(q)(2)(i)]Compressor Components, Gas Service - Valve
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)]0
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)]0
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)]0
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)]0
Component Type [98.236(q)(2)(i)]Compressor Components, Gas Service - Connector
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)]0
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)]0
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)]0
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)]0
Component Type [98.236(q)(2)(i)]Compressor Components, Gas Service - Open-ended Line
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)]0
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)]0
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)]0
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)]0
Component Type [98.236(q)(2)(i)]Compressor Components, Gas Service - Pressure Relief Valve
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)]0
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)]0
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)]0
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)]0
Component Type [98.236(q)(2)(i)]Compressor Components, Gas Service - Meter
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)]0
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)]0
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)]0
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)]0
Component Type [98.236(q)(2)(i)]Non-Compressor Components, Gas Service - Valve
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)]0
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)]0
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)]0
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)]0
Component Type [98.236(q)(2)(i)]Non-Compressor Components, Gas Service - Connector
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)]0
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)]0
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)]0
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)]0
Component Type [98.236(q)(2)(i)]Non-Compressor Components, Gas Service - Open-ended Line
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)]0
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)]0
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)]0
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)]0
Component Type [98.236(q)(2)(i)]Non-Compressor components, Gas Service - Pressure Relief Valve
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)]0
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)]0
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)]0
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)]0
Component Type [98.236(q)(2)(i)]Non-Compressor components, Gas Service - Meter
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)]0
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)]0
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)]0
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)]0