Ventilation Monitoring Point that corresponds to centralized monitoring point or individual shaft from previous tab [§98.326(l)] | Nebo (41) |
Quarter | 1 |
Dates where active ventilation of mining operations is taking place (MM/DD/YYYY) [§98.326(l)] - Start date | 2020-01-01 |
Stop date | 2020-03-31 |
Method used for flow rate [§98.326(f), (r), (s)] | Monitored using 98.324(b)(2) |
V - Quarterly volumetric flow rate used in Eq. FF-1 (acfm or scfm per selection in column A7) [§98.326(f)] | 298668 |
Specify units for parameter V, quarterly volumetric flow rate [§98.326(f)] | acfm |
Length of time that substitute data are used for the quarterly volumetric flow rate used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(f)] | |
Location of each measurement of flow rate used in Eq. FF-1 [§98.326(f)] | Nebo (41) |
Date of each measurement of flow rate used in Eq. FF-1 (MM/DD/YYYY) [§98.326(f)] | 2020-01-29 |
Dates when continuous monitoring equipment for the flow rate is not properly functioning, if applicable (MM/DD/YYYY) [§98.326(n)] - Start date | |
Stop date | |
Method used for concentration [§98.326(g), (r), (s)] | Monitored using 98.324(b)(2) |
C - Quarterly CH4 concentration used in Eq. FF-1 (volume %) [§98.326(g)] | 0.169 |
Was Eq. FF-9 required to calculate CH4 concentration? [§98.326(o)] | No |
If yes, provide the gaseous organic concentration correction factor, used in Eq. FF-9 [§98.326(o)] | |
Length of time that substitute data are used for the quarterly CH4 concentration (hours) [§98.3(c)(8), §98.326(g)] | |
Location of each measurement of concentration [§98.326(g)] | Nebo (41) |
Date of each measurement of concentration (MM/DD/YYYY) [§98.326(g)] | 2020-01-29 |
Dates when continuous monitoring equipment for the concentration is not properly functioning, if applicable (MM/DD/YYYY) [§98.326(n)] - Start date | |
Stop date | |
T - Temperature used in Eq. FF-1 (°R) [§98.326(o)] | 497.67 |
Length of time that substitute data are used for the temperature used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(o)] | |
P - Absolute Pressure used in Eq. FF-1 (atm) [§98.326(o)] | 0.991 |
Length of time that substitute data are used for the pressure used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(o)] | |
Were the Quarterly Ventilation Flow Rate and Quarterly CH4 Concentration measured on the same basis? [§98.326(f)-(g)] | Flow rate and CH4 concentration were measured on a dry basis |
Was a flow meter used? [§98.326(f)-(g)] | A flow meter was used and the flow meter automatically corrected for moisture content |
fH2O - Moisture content used in Eq. FF-1 (cubic feet water per cubic feet biogas) [§98.326(o)] | |
Length of time that substitute data are used for the moisture content used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(o)] | |
Moisture correction factor used in Eq. FF-1 [§98.326(o)] | 1 |
Length of time that substitute data are used for the moisture correction factor used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(o)] | |
CH4V - Quarterly CH4 liberated from ventilation monitoring point (MT CH4) [§98.326(a)] --- Output of Eq. FF-1 | 1309.3 |
File name of MSHA report used to report quarterly CH4 concentration and volumetric flow rate [§98.326(a)] | |
Ventilation Monitoring Point that corresponds to centralized monitoring point or individual shaft from previous tab [§98.326(l)] | Wolf Hollow |
Quarter | 1 |
Dates where active ventilation of mining operations is taking place (MM/DD/YYYY) [§98.326(l)] - Start date | 2020-01-01 |
Stop date | 2020-03-31 |
Method used for flow rate [§98.326(f), (r), (s)] | Monitored using 98.324(b)(2) |
V - Quarterly volumetric flow rate used in Eq. FF-1 (acfm or scfm per selection in column A7) [§98.326(f)] | 556110 |
Specify units for parameter V, quarterly volumetric flow rate [§98.326(f)] | acfm |
Length of time that substitute data are used for the quarterly volumetric flow rate used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(f)] | |
Location of each measurement of flow rate used in Eq. FF-1 [§98.326(f)] | Wolf Hollow |
Date of each measurement of flow rate used in Eq. FF-1 (MM/DD/YYYY) [§98.326(f)] | 2020-01-29 |
Dates when continuous monitoring equipment for the flow rate is not properly functioning, if applicable (MM/DD/YYYY) [§98.326(n)] - Start date | |
Stop date | |
Method used for concentration [§98.326(g), (r), (s)] | Monitored using 98.324(b)(2) |
C - Quarterly CH4 concentration used in Eq. FF-1 (volume %) [§98.326(g)] | 0.06 |
Was Eq. FF-9 required to calculate CH4 concentration? [§98.326(o)] | No |
If yes, provide the gaseous organic concentration correction factor, used in Eq. FF-9 [§98.326(o)] | |
Length of time that substitute data are used for the quarterly CH4 concentration (hours) [§98.3(c)(8), §98.326(g)] | |
Location of each measurement of concentration [§98.326(g)] | Wolf Hollow |
Date of each measurement of concentration (MM/DD/YYYY) [§98.326(g)] | 2020-01-29 |
Dates when continuous monitoring equipment for the concentration is not properly functioning, if applicable (MM/DD/YYYY) [§98.326(n)] - Start date | |
Stop date | |
T - Temperature used in Eq. FF-1 (°R) [§98.326(o)] | 497.67 |
Length of time that substitute data are used for the temperature used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(o)] | |
P - Absolute Pressure used in Eq. FF-1 (atm) [§98.326(o)] | 0.991 |
Length of time that substitute data are used for the pressure used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(o)] | |
Were the Quarterly Ventilation Flow Rate and Quarterly CH4 Concentration measured on the same basis? [§98.326(f)-(g)] | Flow rate and CH4 concentration were measured on a dry basis |
Was a flow meter used? [§98.326(f)-(g)] | A flow meter was used and the flow meter automatically corrected for moisture content |
fH2O - Moisture content used in Eq. FF-1 (cubic feet water per cubic feet biogas) [§98.326(o)] | |
Length of time that substitute data are used for the moisture content used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(o)] | |
Moisture correction factor used in Eq. FF-1 [§98.326(o)] | 1 |
Length of time that substitute data are used for the moisture correction factor used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(o)] | |
CH4V - Quarterly CH4 liberated from ventilation monitoring point (MT CH4) [§98.326(a)] --- Output of Eq. FF-1 | 860.42 |
File name of MSHA report used to report quarterly CH4 concentration and volumetric flow rate [§98.326(a)] | |
Ventilation Monitoring Point that corresponds to centralized monitoring point or individual shaft from previous tab [§98.326(l)] | Nebo (41) |
Quarter | 2 |
Dates where active ventilation of mining operations is taking place (MM/DD/YYYY) [§98.326(l)] - Start date | 2020-04-01 |
Stop date | 2020-06-30 |
Method used for flow rate [§98.326(f), (r), (s)] | Monitored using 98.324(b)(2) |
V - Quarterly volumetric flow rate used in Eq. FF-1 (acfm or scfm per selection in column A7) [§98.326(f)] | 303383 |
Specify units for parameter V, quarterly volumetric flow rate [§98.326(f)] | acfm |
Length of time that substitute data are used for the quarterly volumetric flow rate used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(f)] | |
Location of each measurement of flow rate used in Eq. FF-1 [§98.326(f)] | Nebo (41) |
Date of each measurement of flow rate used in Eq. FF-1 (MM/DD/YYYY) [§98.326(f)] | 2020-04-14 |
Dates when continuous monitoring equipment for the flow rate is not properly functioning, if applicable (MM/DD/YYYY) [§98.326(n)] - Start date | |
Stop date | |
Method used for concentration [§98.326(g), (r), (s)] | Monitored using 98.324(b)(2) |
C - Quarterly CH4 concentration used in Eq. FF-1 (volume %) [§98.326(g)] | 0.019 |
Was Eq. FF-9 required to calculate CH4 concentration? [§98.326(o)] | No |
If yes, provide the gaseous organic concentration correction factor, used in Eq. FF-9 [§98.326(o)] | |
Length of time that substitute data are used for the quarterly CH4 concentration (hours) [§98.3(c)(8), §98.326(g)] | |
Location of each measurement of concentration [§98.326(g)] | Nebo (41) |
Date of each measurement of concentration (MM/DD/YYYY) [§98.326(g)] | 2020-04-14 |
Dates when continuous monitoring equipment for the concentration is not properly functioning, if applicable (MM/DD/YYYY) [§98.326(n)] - Start date | |
Stop date | |
T - Temperature used in Eq. FF-1 (°R) [§98.326(o)] | 503.67 |
Length of time that substitute data are used for the temperature used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(o)] | |
P - Absolute Pressure used in Eq. FF-1 (atm) [§98.326(o)] | 0.997 |
Length of time that substitute data are used for the pressure used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(o)] | |
Were the Quarterly Ventilation Flow Rate and Quarterly CH4 Concentration measured on the same basis? [§98.326(f)-(g)] | Flow rate and CH4 concentration were measured on a dry basis |
Was a flow meter used? [§98.326(f)-(g)] | A flow meter was used and the flow meter automatically corrected for moisture content |
fH2O - Moisture content used in Eq. FF-1 (cubic feet water per cubic feet biogas) [§98.326(o)] | |
Length of time that substitute data are used for the moisture content used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(o)] | |
Moisture correction factor used in Eq. FF-1 [§98.326(o)] | 1 |
Length of time that substitute data are used for the moisture correction factor used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(o)] | |
CH4V - Quarterly CH4 liberated from ventilation monitoring point (MT CH4) [§98.326(a)] --- Output of Eq. FF-1 | 155.54 |
File name of MSHA report used to report quarterly CH4 concentration and volumetric flow rate [§98.326(a)] | |
Ventilation Monitoring Point that corresponds to centralized monitoring point or individual shaft from previous tab [§98.326(l)] | Wolf Hollow |
Quarter | 2 |
Dates where active ventilation of mining operations is taking place (MM/DD/YYYY) [§98.326(l)] - Start date | 2020-04-01 |
Stop date | 2020-06-30 |
Method used for flow rate [§98.326(f), (r), (s)] | Monitored using 98.324(b)(2) |
V - Quarterly volumetric flow rate used in Eq. FF-1 (acfm or scfm per selection in column A7) [§98.326(f)] | 530588 |
Specify units for parameter V, quarterly volumetric flow rate [§98.326(f)] | acfm |
Length of time that substitute data are used for the quarterly volumetric flow rate used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(f)] | |
Location of each measurement of flow rate used in Eq. FF-1 [§98.326(f)] | Wolf Hollow |
Date of each measurement of flow rate used in Eq. FF-1 (MM/DD/YYYY) [§98.326(f)] | 2020-04-06 |
Dates when continuous monitoring equipment for the flow rate is not properly functioning, if applicable (MM/DD/YYYY) [§98.326(n)] - Start date | |
Stop date | |
Method used for concentration [§98.326(g), (r), (s)] | Monitored using 98.324(b)(2) |
C - Quarterly CH4 concentration used in Eq. FF-1 (volume %) [§98.326(g)] | 0.08 |
Was Eq. FF-9 required to calculate CH4 concentration? [§98.326(o)] | No |
If yes, provide the gaseous organic concentration correction factor, used in Eq. FF-9 [§98.326(o)] | |
Length of time that substitute data are used for the quarterly CH4 concentration (hours) [§98.3(c)(8), §98.326(g)] | |
Location of each measurement of concentration [§98.326(g)] | Wolf Hollow |
Date of each measurement of concentration (MM/DD/YYYY) [§98.326(g)] | 2020-04-06 |
Dates when continuous monitoring equipment for the concentration is not properly functioning, if applicable (MM/DD/YYYY) [§98.326(n)] - Start date | |
Stop date | |
T - Temperature used in Eq. FF-1 (°R) [§98.326(o)] | 534.67 |
Length of time that substitute data are used for the temperature used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(o)] | |
P - Absolute Pressure used in Eq. FF-1 (atm) [§98.326(o)] | 0.989 |
Length of time that substitute data are used for the pressure used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(o)] | |
Were the Quarterly Ventilation Flow Rate and Quarterly CH4 Concentration measured on the same basis? [§98.326(f)-(g)] | Flow rate and CH4 concentration were measured on a dry basis |
Was a flow meter used? [§98.326(f)-(g)] | A flow meter was used and the flow meter automatically corrected for moisture content |
fH2O - Moisture content used in Eq. FF-1 (cubic feet water per cubic feet biogas) [§98.326(o)] | |
Length of time that substitute data are used for the moisture content used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(o)] | |
Moisture correction factor used in Eq. FF-1 [§98.326(o)] | 1 |
Length of time that substitute data are used for the moisture correction factor used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(o)] | |
CH4V - Quarterly CH4 liberated from ventilation monitoring point (MT CH4) [§98.326(a)] --- Output of Eq. FF-1 | 1017.12 |
File name of MSHA report used to report quarterly CH4 concentration and volumetric flow rate [§98.326(a)] | |
Ventilation Monitoring Point that corresponds to centralized monitoring point or individual shaft from previous tab [§98.326(l)] | Nebo (41) |
Quarter | 3 |
Dates where active ventilation of mining operations is taking place (MM/DD/YYYY) [§98.326(l)] - Start date | 2020-07-01 |
Stop date | 2020-09-30 |
Method used for flow rate [§98.326(f), (r), (s)] | Monitored using 98.324(b)(2) |
V - Quarterly volumetric flow rate used in Eq. FF-1 (acfm or scfm per selection in column A7) [§98.326(f)] | 292537 |
Specify units for parameter V, quarterly volumetric flow rate [§98.326(f)] | acfm |
Length of time that substitute data are used for the quarterly volumetric flow rate used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(f)] | |
Location of each measurement of flow rate used in Eq. FF-1 [§98.326(f)] | Nebo (41) |
Date of each measurement of flow rate used in Eq. FF-1 (MM/DD/YYYY) [§98.326(f)] | 2020-05-19 |
Dates when continuous monitoring equipment for the flow rate is not properly functioning, if applicable (MM/DD/YYYY) [§98.326(n)] - Start date | |
Stop date | |
Method used for concentration [§98.326(g), (r), (s)] | Monitored using 98.324(b)(2) |
C - Quarterly CH4 concentration used in Eq. FF-1 (volume %) [§98.326(g)] | 0.279 |
Was Eq. FF-9 required to calculate CH4 concentration? [§98.326(o)] | No |
If yes, provide the gaseous organic concentration correction factor, used in Eq. FF-9 [§98.326(o)] | |
Length of time that substitute data are used for the quarterly CH4 concentration (hours) [§98.3(c)(8), §98.326(g)] | |
Location of each measurement of concentration [§98.326(g)] | Nebo (41) |
Date of each measurement of concentration (MM/DD/YYYY) [§98.326(g)] | 2020-05-19 |
Dates when continuous monitoring equipment for the concentration is not properly functioning, if applicable (MM/DD/YYYY) [§98.326(n)] - Start date | |
Stop date | |
T - Temperature used in Eq. FF-1 (°R) [§98.326(o)] | 535.67 |
Length of time that substitute data are used for the temperature used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(o)] | |
P - Absolute Pressure used in Eq. FF-1 (atm) [§98.326(o)] | 0.981 |
Length of time that substitute data are used for the pressure used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(o)] | |
Were the Quarterly Ventilation Flow Rate and Quarterly CH4 Concentration measured on the same basis? [§98.326(f)-(g)] | Flow rate and CH4 concentration were measured on a dry basis |
Was a flow meter used? [§98.326(f)-(g)] | A flow meter was used and the flow meter automatically corrected for moisture content |
fH2O - Moisture content used in Eq. FF-1 (cubic feet water per cubic feet biogas) [§98.326(o)] | |
Length of time that substitute data are used for the moisture content used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(o)] | |
Moisture correction factor used in Eq. FF-1 [§98.326(o)] | 1 |
Length of time that substitute data are used for the moisture correction factor used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(o)] | |
CH4V - Quarterly CH4 liberated from ventilation monitoring point (MT CH4) [§98.326(a)] --- Output of Eq. FF-1 | 1964.79 |
File name of MSHA report used to report quarterly CH4 concentration and volumetric flow rate [§98.326(a)] | |
Ventilation Monitoring Point that corresponds to centralized monitoring point or individual shaft from previous tab [§98.326(l)] | Wolf Hollow |
Quarter | 3 |
Dates where active ventilation of mining operations is taking place (MM/DD/YYYY) [§98.326(l)] - Start date | 2020-07-01 |
Stop date | 2020-09-30 |
Method used for flow rate [§98.326(f), (r), (s)] | Monitored using 98.324(b)(2) |
V - Quarterly volumetric flow rate used in Eq. FF-1 (acfm or scfm per selection in column A7) [§98.326(f)] | 541924 |
Specify units for parameter V, quarterly volumetric flow rate [§98.326(f)] | acfm |
Length of time that substitute data are used for the quarterly volumetric flow rate used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(f)] | |
Location of each measurement of flow rate used in Eq. FF-1 [§98.326(f)] | Wolf Hollow |
Date of each measurement of flow rate used in Eq. FF-1 (MM/DD/YYYY) [§98.326(f)] | 2020-05-19 |
Dates when continuous monitoring equipment for the flow rate is not properly functioning, if applicable (MM/DD/YYYY) [§98.326(n)] - Start date | |
Stop date | |
Method used for concentration [§98.326(g), (r), (s)] | Monitored using 98.324(b)(2) |
C - Quarterly CH4 concentration used in Eq. FF-1 (volume %) [§98.326(g)] | 0.03 |
Was Eq. FF-9 required to calculate CH4 concentration? [§98.326(o)] | No |
If yes, provide the gaseous organic concentration correction factor, used in Eq. FF-9 [§98.326(o)] | |
Length of time that substitute data are used for the quarterly CH4 concentration (hours) [§98.3(c)(8), §98.326(g)] | |
Location of each measurement of concentration [§98.326(g)] | Wolf Hollow |
Date of each measurement of concentration (MM/DD/YYYY) [§98.326(g)] | 2020-05-19 |
Dates when continuous monitoring equipment for the concentration is not properly functioning, if applicable (MM/DD/YYYY) [§98.326(n)] - Start date | |
Stop date | |
T - Temperature used in Eq. FF-1 (°R) [§98.326(o)] | 535.67 |
Length of time that substitute data are used for the temperature used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(o)] | |
P - Absolute Pressure used in Eq. FF-1 (atm) [§98.326(o)] | 0.981 |
Length of time that substitute data are used for the pressure used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(o)] | |
Were the Quarterly Ventilation Flow Rate and Quarterly CH4 Concentration measured on the same basis? [§98.326(f)-(g)] | Flow rate and CH4 concentration were measured on a dry basis |
Was a flow meter used? [§98.326(f)-(g)] | A flow meter was used and the flow meter automatically corrected for moisture content |
fH2O - Moisture content used in Eq. FF-1 (cubic feet water per cubic feet biogas) [§98.326(o)] | |
Length of time that substitute data are used for the moisture content used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(o)] | |
Moisture correction factor used in Eq. FF-1 [§98.326(o)] | 1 |
Length of time that substitute data are used for the moisture correction factor used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(o)] | |
CH4V - Quarterly CH4 liberated from ventilation monitoring point (MT CH4) [§98.326(a)] --- Output of Eq. FF-1 | 389.98 |
File name of MSHA report used to report quarterly CH4 concentration and volumetric flow rate [§98.326(a)] | |
Ventilation Monitoring Point that corresponds to centralized monitoring point or individual shaft from previous tab [§98.326(l)] | Nebo (41) |
Quarter | 4 |
Dates where active ventilation of mining operations is taking place (MM/DD/YYYY) [§98.326(l)] - Start date | 2020-10-01 |
Stop date | 2020-12-31 |
Method used for flow rate [§98.326(f), (r), (s)] | Monitored using 98.324(b)(2) |
V - Quarterly volumetric flow rate used in Eq. FF-1 (acfm or scfm per selection in column A7) [§98.326(f)] | 298919 |
Specify units for parameter V, quarterly volumetric flow rate [§98.326(f)] | acfm |
Length of time that substitute data are used for the quarterly volumetric flow rate used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(f)] | |
Location of each measurement of flow rate used in Eq. FF-1 [§98.326(f)] | Nebo (41) |
Date of each measurement of flow rate used in Eq. FF-1 (MM/DD/YYYY) [§98.326(f)] | 2020-10-28 |
Dates when continuous monitoring equipment for the flow rate is not properly functioning, if applicable (MM/DD/YYYY) [§98.326(n)] - Start date | |
Stop date | |
Method used for concentration [§98.326(g), (r), (s)] | Monitored using 98.324(b)(2) |
C - Quarterly CH4 concentration used in Eq. FF-1 (volume %) [§98.326(g)] | 0.26 |
Was Eq. FF-9 required to calculate CH4 concentration? [§98.326(o)] | No |
If yes, provide the gaseous organic concentration correction factor, used in Eq. FF-9 [§98.326(o)] | |
Length of time that substitute data are used for the quarterly CH4 concentration (hours) [§98.3(c)(8), §98.326(g)] | |
Location of each measurement of concentration [§98.326(g)] | Nebo (41) |
Date of each measurement of concentration (MM/DD/YYYY) [§98.326(g)] | 2020-10-28 |
Dates when continuous monitoring equipment for the concentration is not properly functioning, if applicable (MM/DD/YYYY) [§98.326(n)] - Start date | |
Stop date | |
T - Temperature used in Eq. FF-1 (°R) [§98.326(o)] | 521.67 |
Length of time that substitute data are used for the temperature used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(o)] | |
P - Absolute Pressure used in Eq. FF-1 (atm) [§98.326(o)] | 0.989 |
Length of time that substitute data are used for the pressure used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(o)] | |
Were the Quarterly Ventilation Flow Rate and Quarterly CH4 Concentration measured on the same basis? [§98.326(f)-(g)] | Flow rate and CH4 concentration were measured on a dry basis |
Was a flow meter used? [§98.326(f)-(g)] | A flow meter was used and the flow meter automatically corrected for moisture content |
fH2O - Moisture content used in Eq. FF-1 (cubic feet water per cubic feet biogas) [§98.326(o)] | |
Length of time that substitute data are used for the moisture content used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(o)] | |
Moisture correction factor used in Eq. FF-1 [§98.326(o)] | 1 |
Length of time that substitute data are used for the moisture correction factor used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(o)] | |
CH4V - Quarterly CH4 liberated from ventilation monitoring point (MT CH4) [§98.326(a)] --- Output of Eq. FF-1 | 1951.13 |
File name of MSHA report used to report quarterly CH4 concentration and volumetric flow rate [§98.326(a)] | |
Ventilation Monitoring Point that corresponds to centralized monitoring point or individual shaft from previous tab [§98.326(l)] | Wolf Hollow |
Quarter | 4 |
Dates where active ventilation of mining operations is taking place (MM/DD/YYYY) [§98.326(l)] - Start date | 2020-10-01 |
Stop date | 2020-12-31 |
Method used for flow rate [§98.326(f), (r), (s)] | Monitored using 98.324(b)(2) |
V - Quarterly volumetric flow rate used in Eq. FF-1 (acfm or scfm per selection in column A7) [§98.326(f)] | 534153 |
Specify units for parameter V, quarterly volumetric flow rate [§98.326(f)] | acfm |
Length of time that substitute data are used for the quarterly volumetric flow rate used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(f)] | |
Location of each measurement of flow rate used in Eq. FF-1 [§98.326(f)] | Wolf Hollow |
Date of each measurement of flow rate used in Eq. FF-1 (MM/DD/YYYY) [§98.326(f)] | 2020-10-28 |
Dates when continuous monitoring equipment for the flow rate is not properly functioning, if applicable (MM/DD/YYYY) [§98.326(n)] - Start date | |
Stop date | |
Method used for concentration [§98.326(g), (r), (s)] | Monitored using 98.324(b)(2) |
C - Quarterly CH4 concentration used in Eq. FF-1 (volume %) [§98.326(g)] | 0.08 |
Was Eq. FF-9 required to calculate CH4 concentration? [§98.326(o)] | No |
If yes, provide the gaseous organic concentration correction factor, used in Eq. FF-9 [§98.326(o)] | |
Length of time that substitute data are used for the quarterly CH4 concentration (hours) [§98.3(c)(8), §98.326(g)] | |
Location of each measurement of concentration [§98.326(g)] | Wolf Hollow |
Date of each measurement of concentration (MM/DD/YYYY) [§98.326(g)] | 2020-10-28 |
Dates when continuous monitoring equipment for the concentration is not properly functioning, if applicable (MM/DD/YYYY) [§98.326(n)] - Start date | |
Stop date | |
T - Temperature used in Eq. FF-1 (°R) [§98.326(o)] | 521.67 |
Length of time that substitute data are used for the temperature used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(o)] | |
P - Absolute Pressure used in Eq. FF-1 (atm) [§98.326(o)] | 0.989 |
Length of time that substitute data are used for the pressure used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(o)] | |
Were the Quarterly Ventilation Flow Rate and Quarterly CH4 Concentration measured on the same basis? [§98.326(f)-(g)] | Flow rate and CH4 concentration were measured on a dry basis |
Was a flow meter used? [§98.326(f)-(g)] | A flow meter was used and the flow meter automatically corrected for moisture content |
fH2O - Moisture content used in Eq. FF-1 (cubic feet water per cubic feet biogas) [§98.326(o)] | |
Length of time that substitute data are used for the moisture content used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(o)] | |
Moisture correction factor used in Eq. FF-1 [§98.326(o)] | 1 |
Length of time that substitute data are used for the moisture correction factor used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(o)] | |
CH4V - Quarterly CH4 liberated from ventilation monitoring point (MT CH4) [§98.326(a)] --- Output of Eq. FF-1 | 1072.79 |
File name of MSHA report used to report quarterly CH4 concentration and volumetric flow rate [§98.326(a)] | |