MSHA Individual Identification Number: | 42-01890 |
Quarterly CH4 emissions (net) from all ventilation and degasification systems (facility total) (MT CH4, unrounded) [§98.326(d)] | 434.21 |
Quarterly CO2 emissions from onsite destruction of coal mine gas CH4, where the gas is not a fuel input for energy generation or use (e.g., flaring) (MT CO2, unrounded) [§98.326(e)] | 0 |
Quarterly CH4 emissions (net) from all ventilation and degasification systems (facility total) (MT CH4, unrounded) [§98.326(d)] | 958.26 |
Quarterly CO2 emissions from onsite destruction of coal mine gas CH4, where the gas is not a fuel input for energy generation or use (e.g., flaring) (MT CO2, unrounded) [§98.326(e)] | 0 |
Quarterly CH4 emissions (net) from all ventilation and degasification systems (facility total) (MT CH4, unrounded) [§98.326(d)] | 0 |
Quarterly CO2 emissions from onsite destruction of coal mine gas CH4, where the gas is not a fuel input for energy generation or use (e.g., flaring) (MT CO2, unrounded) [§98.326(e)] | 0 |
Quarterly CH4 emissions (net) from all ventilation and degasification systems (facility total) (MT CH4, unrounded) [§98.326(d)] | 0 |
Quarterly CO2 emissions from onsite destruction of coal mine gas CH4, where the gas is not a fuel input for energy generation or use (e.g., flaring) (MT CO2, unrounded) [§98.326(e)] | 0 |
Ventilation Monitoring Point that corresponds to centralized monitoring point or individual shaft from previous tab [§98.326(l)] | Dugout Fan |
Quarter | 1 |
Dates where active ventilation of mining operations is taking place (MM/DD/YYYY) [§98.326(l)] - Start date | 2020-01-01 |
Stop date | 2020-03-31 |
Method used for flow rate [§98.326(f), (r), (s)] | Monitored using 98.324(b)(1) |
V - Quarterly volumetric flow rate used in Eq. FF-1 (acfm or scfm per selection in column A7) [§98.326(f)] | 860730 |
Specify units for parameter V, quarterly volumetric flow rate [§98.326(f)] | acfm |
Length of time that substitute data are used for the quarterly volumetric flow rate used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(f)] | 0 |
Location of each measurement of flow rate used in Eq. FF-1 [§98.326(f)] | Dugout Fan |
Date of each measurement of flow rate used in Eq. FF-1 (MM/DD/YYYY) [§98.326(f)] | 2020-02-18 |
Dates when continuous monitoring equipment for the flow rate is not properly functioning, if applicable (MM/DD/YYYY) [§98.326(n)] - Start date | |
Stop date | |
Method used for concentration [§98.326(g), (r), (s)] | Monitored using 98.324(b)(1) |
C - Quarterly CH4 concentration used in Eq. FF-1 (volume %) [§98.326(g)] | 0.0254 |
Was Eq. FF-9 required to calculate CH4 concentration? [§98.326(o)] | No |
If yes, provide the gaseous organic concentration correction factor, used in Eq. FF-9 [§98.326(o)] | |
Length of time that substitute data are used for the quarterly CH4 concentration (hours) [§98.3(c)(8), §98.326(g)] | 0 |
Location of each measurement of concentration [§98.326(g)] | Dugout Fan |
Date of each measurement of concentration (MM/DD/YYYY) [§98.326(g)] | 2020-02-18 |
Dates when continuous monitoring equipment for the concentration is not properly functioning, if applicable (MM/DD/YYYY) [§98.326(n)] - Start date | |
Stop date | |
T - Temperature used in Eq. FF-1 (°R) [§98.326(o)] | 510.67 |
Length of time that substitute data are used for the temperature used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(o)] | 0 |
P - Absolute Pressure used in Eq. FF-1 (atm) [§98.326(o)] | 0.78 |
Length of time that substitute data are used for the pressure used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(o)] | 0 |
Were the Quarterly Ventilation Flow Rate and Quarterly CH4 Concentration measured on the same basis? [§98.326(f)-(g)] | Flow rate was measured on a wet basis and CH4 concentration was measured on a dry basis |
Was a flow meter used? [§98.326(f)-(g)] | A flow meter was not used |
fH2O - Moisture content used in Eq. FF-1 (cubic feet water per cubic feet biogas) [§98.326(o)] | 0.009 |
Length of time that substitute data are used for the moisture content used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(o)] | 0 |
Moisture correction factor used in Eq. FF-1 [§98.326(o)] | 0.991 |
Length of time that substitute data are used for the moisture correction factor used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(o)] | 0 |
CH4V - Quarterly CH4 liberated from ventilation monitoring point (MT CH4) [§98.326(a)] --- Output of Eq. FF-1 | 434.21 |
File name of MSHA report used to report quarterly CH4 concentration and volumetric flow rate [§98.326(a)] | |
Ventilation Monitoring Point that corresponds to centralized monitoring point or individual shaft from previous tab [§98.326(l)] | Dugout Fan |
Quarter | 2 |
Dates where active ventilation of mining operations is taking place (MM/DD/YYYY) [§98.326(l)] - Start date | 2020-04-01 |
Stop date | 2020-06-30 |
Method used for flow rate [§98.326(f), (r), (s)] | Monitored using 98.324(b)(1) |
V - Quarterly volumetric flow rate used in Eq. FF-1 (acfm or scfm per selection in column A7) [§98.326(f)] | 953350 |
Specify units for parameter V, quarterly volumetric flow rate [§98.326(f)] | acfm |
Length of time that substitute data are used for the quarterly volumetric flow rate used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(f)] | 0 |
Location of each measurement of flow rate used in Eq. FF-1 [§98.326(f)] | Dugout Fan |
Date of each measurement of flow rate used in Eq. FF-1 (MM/DD/YYYY) [§98.326(f)] | 2020-06-08 |
Dates when continuous monitoring equipment for the flow rate is not properly functioning, if applicable (MM/DD/YYYY) [§98.326(n)] - Start date | |
Stop date | |
Method used for concentration [§98.326(g), (r), (s)] | Monitored using 98.324(b)(1) |
C - Quarterly CH4 concentration used in Eq. FF-1 (volume %) [§98.326(g)] | 0.0512 |
Was Eq. FF-9 required to calculate CH4 concentration? [§98.326(o)] | No |
If yes, provide the gaseous organic concentration correction factor, used in Eq. FF-9 [§98.326(o)] | |
Length of time that substitute data are used for the quarterly CH4 concentration (hours) [§98.3(c)(8), §98.326(g)] | 0 |
Location of each measurement of concentration [§98.326(g)] | Dugout Fan |
Date of each measurement of concentration (MM/DD/YYYY) [§98.326(g)] | 2020-06-08 |
Dates when continuous monitoring equipment for the concentration is not properly functioning, if applicable (MM/DD/YYYY) [§98.326(n)] - Start date | |
Stop date | |
T - Temperature used in Eq. FF-1 (°R) [§98.326(o)] | 512.67 |
Length of time that substitute data are used for the temperature used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(o)] | 0 |
P - Absolute Pressure used in Eq. FF-1 (atm) [§98.326(o)] | 0.78 |
Length of time that substitute data are used for the pressure used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(o)] | 0 |
Were the Quarterly Ventilation Flow Rate and Quarterly CH4 Concentration measured on the same basis? [§98.326(f)-(g)] | Flow rate was measured on a wet basis and CH4 concentration was measured on a dry basis |
Was a flow meter used? [§98.326(f)-(g)] | A flow meter was not used |
fH2O - Moisture content used in Eq. FF-1 (cubic feet water per cubic feet biogas) [§98.326(o)] | 0.0124 |
Length of time that substitute data are used for the moisture content used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(o)] | 0 |
Moisture correction factor used in Eq. FF-1 [§98.326(o)] | 0.9876 |
Length of time that substitute data are used for the moisture correction factor used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(o)] | 0 |
CH4V - Quarterly CH4 liberated from ventilation monitoring point (MT CH4) [§98.326(a)] --- Output of Eq. FF-1 | 958.26 |
File name of MSHA report used to report quarterly CH4 concentration and volumetric flow rate [§98.326(a)] | |
Quarter | Quarter 1 (Jan-Mar) |
CH4VTotal - Facility total quarterly CH4 liberated from ventilation systems (MT CH4, rounded) [§98.3(c)(4)(iii)] --- [D2=(A2 or A4)] | 434.21 |
CH4DTotal - Facility total quarterly CH4 liberated from all degasification monitoring points (MT CH4, rounded) [§98.3(c)(4)(iii)] --- [D3=(B2 or B4)] | 0 |
CH4DestroyedTotal - Facility total quarterly CH4 destroyed at the mine and transported offsite (MT CH4, rounded) [§98.3(c)(4)(iii)] --- [D4=(C2 or C4)] | 0 |
CH4emitted(net) - Facility total quarterly net CH4 emissions to the atmosphere from the mine according to Eq. FF-7 (MT CH4, rounded) [§98.3(c)(4)(iii)] --- [D5=D2+D3-D4] | 434.21 |
Quarter | Quarter 2 (Apr-Jun) |
CH4VTotal - Facility total quarterly CH4 liberated from ventilation systems (MT CH4, rounded) [§98.3(c)(4)(iii)] --- [D2=(A2 or A4)] | 958.26 |
CH4DTotal - Facility total quarterly CH4 liberated from all degasification monitoring points (MT CH4, rounded) [§98.3(c)(4)(iii)] --- [D3=(B2 or B4)] | 0 |
CH4DestroyedTotal - Facility total quarterly CH4 destroyed at the mine and transported offsite (MT CH4, rounded) [§98.3(c)(4)(iii)] --- [D4=(C2 or C4)] | 0 |
CH4emitted(net) - Facility total quarterly net CH4 emissions to the atmosphere from the mine according to Eq. FF-7 (MT CH4, rounded) [§98.3(c)(4)(iii)] --- [D5=D2+D3-D4] | 958.26 |
Quarter | Quarter 3 (Jul-Sep) |
CH4VTotal - Facility total quarterly CH4 liberated from ventilation systems (MT CH4, rounded) [§98.3(c)(4)(iii)] --- [D2=(A2 or A4)] | 0 |
CH4DTotal - Facility total quarterly CH4 liberated from all degasification monitoring points (MT CH4, rounded) [§98.3(c)(4)(iii)] --- [D3=(B2 or B4)] | 0 |
CH4DestroyedTotal - Facility total quarterly CH4 destroyed at the mine and transported offsite (MT CH4, rounded) [§98.3(c)(4)(iii)] --- [D4=(C2 or C4)] | 0 |
CH4emitted(net) - Facility total quarterly net CH4 emissions to the atmosphere from the mine according to Eq. FF-7 (MT CH4, rounded) [§98.3(c)(4)(iii)] --- [D5=D2+D3-D4] | 0 |
Quarter | Quarter 4 (Oct-Dec) |
CH4VTotal - Facility total quarterly CH4 liberated from ventilation systems (MT CH4, rounded) [§98.3(c)(4)(iii)] --- [D2=(A2 or A4)] | 0 |
CH4DTotal - Facility total quarterly CH4 liberated from all degasification monitoring points (MT CH4, rounded) [§98.3(c)(4)(iii)] --- [D3=(B2 or B4)] | 0 |
CH4DestroyedTotal - Facility total quarterly CH4 destroyed at the mine and transported offsite (MT CH4, rounded) [§98.3(c)(4)(iii)] --- [D4=(C2 or C4)] | 0 |
CH4emitted(net) - Facility total quarterly net CH4 emissions to the atmosphere from the mine according to Eq. FF-7 (MT CH4, rounded) [§98.3(c)(4)(iii)] --- [D5=D2+D3-D4] | 0 |