Facility Name:Dugout Canyon Mine
Facility Identifier:
Facility Reporting Year:2020
Facility Location:
Address: 5719 North Dugout Canyon Road
City: Wellington
State: UT
Postal Code: 84542

Facility Site Details:
CO2 equivalent emissions from facility subparts C-II, SS, and TT (metric tons):35,110.3
CO2 equivalent emissions from supplier subparts LL-QQ (metric tons):
Biogenic CO2 emissions from facility subparts C-II, SS, and TT (metric tons):0
Cogeneration Unit Emissions Indicator:N
GHG Report Start Date:2020-01-01
GHG Report End Date:2020-12-31
Description of Changes to Calculation Methodology:
Plant Code Indicator:N
Primary NAICS Code:212112
Second Primary NAICS Code:

Parent Company Details:
Parent Company Name:WOLVERINE FUELS LLC
Address:9815 South Monroe Street, Sandy,  UT 84070
Percent Ownership Interest:100

Subpart C: General Stationary Fuel Combustion

Gas Information Details

Gas NameCarbon Dioxide
Gas Quantity295.8 (Metric Tons)
Own Result?

Gas NameBiogenic Carbon dioxide
Gas Quantity0 (Metric Tons)
Own Result?

Gas NameMethane
Gas Quantity0.04 (Metric Tons)
Own Result?

Gas NameNitrous Oxide
Gas Quantity0.006 (Metric Tons)
Own Result?

Unit Details:
Unit Name : Boiler
Unit Type : OB (Boiler, other)
Unit Description :
Individual Unit Details:
Use Ivt Indicator: Y
Maximum Rated Heat Input Capacity: 1.37 (mmBtu/hr)

Emission Details:
Annual CO2 mass emissions from sorbent: 0 (Metric Tons)
Annual Biogenic CO2 Emissions: 0 (metric tons)

Tier Fuel Details:
Fuel : Bituminous
Tier Name : Tier 3 (Equation C-3, solid fuel)
Tier Methodology Start Date : 2020-01-01
Tier Methodology End Date : 2020-12-31

Fuel Emission Details :
Total CO2 emissionsTotal CH4 emissionsTotal N2O emissionsTotal CH4 emissions CO2eTotal N2O emissions CO2e
295.8 (Metric Tons) 0.04 (Metric Tons) 0.006 (Metric Tons) 1 (Metric Tons) 1.7 (Metric Tons)

Carbon Content Substitute Data Information :
Total number of valid carbon content determinations : 0
Total number of carbon content substitute data values : 0
Frequency of carbon content determinations : Other (specify)
Other specified frequency of carbon content determinations : NA
Total number of operating hours in the reporting year for which missing data substitution was used for fuel usage : 0



Subpart FF: Underground Coal Mines

Gas Information Details

Gas NameCarbon Dioxide
Gas Quantity0 (Metric Tons)
Own Result?

Gas NameMethane
Gas Quantity1,392.47 (Metric Tons)
Own Result?


SubpartFFSummaryDetails:
MSHA Individual Identification Number:42-01890
Quarterly CH4 emissions (net) from all ventilation and degasification systems (facility total) (MT CH4, unrounded) [§98.326(d)]434.21
Quarterly CO2 emissions from onsite destruction of coal mine gas CH4, where the gas is not a fuel input for energy generation or use (e.g., flaring) (MT CO2, unrounded) [§98.326(e)]0
Quarterly CH4 emissions (net) from all ventilation and degasification systems (facility total) (MT CH4, unrounded) [§98.326(d)]958.26
Quarterly CO2 emissions from onsite destruction of coal mine gas CH4, where the gas is not a fuel input for energy generation or use (e.g., flaring) (MT CO2, unrounded) [§98.326(e)]0
Quarterly CH4 emissions (net) from all ventilation and degasification systems (facility total) (MT CH4, unrounded) [§98.326(d)]0
Quarterly CO2 emissions from onsite destruction of coal mine gas CH4, where the gas is not a fuel input for energy generation or use (e.g., flaring) (MT CO2, unrounded) [§98.326(e)]0
Quarterly CH4 emissions (net) from all ventilation and degasification systems (facility total) (MT CH4, unrounded) [§98.326(d)]0
Quarterly CO2 emissions from onsite destruction of coal mine gas CH4, where the gas is not a fuel input for energy generation or use (e.g., flaring) (MT CO2, unrounded) [§98.326(e)]0


WellAndShaftDetails:


WellAndShaftCollectionRowDetails:
Well and Shaft ID or Name [§98.326(r)]Dugout Fan
Identify if this is a well or a shaft [§98.326(r)]Shaft
Gas Collection System Unit ID or Name (if applicable) [§98.326(q)]
Description [§98.326(r)]exhaust vent shaft
Additional Information for Description [§98.326(r)]
Start date of well or shaft (MM/DD/YYYY) [§98.326(r)]2020-01-01
Close date of well or shaft (MM/DD/YYYY) [§98.326(r)]2020-12-31
Number of days the well or shaft was in operation during the reporting year [§98.326(r)]365
Indicate whether the well or shaft is monitored individually, or as part of a centralized monitoring point [§98.326(r)]monitored individually
Identify the Centralized Monitoring Point [§98.326(s)]


VentilationQuarterlyDetails:


VentilationMonitoringQuarterlyRowDetails:
Ventilation Monitoring Point that corresponds to centralized monitoring point or individual shaft from previous tab [§98.326(l)]Dugout Fan
Quarter1
Dates where active ventilation of mining operations is taking place (MM/DD/YYYY) [§98.326(l)] - Start date2020-01-01
Stop date2020-03-31
Method used for flow rate [§98.326(f), (r), (s)]Monitored using 98.324(b)(1)
V - Quarterly volumetric flow rate used in Eq. FF-1 (acfm or scfm per selection in column A7) [§98.326(f)]860730
Specify units for parameter V, quarterly volumetric flow rate [§98.326(f)]acfm
Length of time that substitute data are used for the quarterly volumetric flow rate used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(f)]0
Location of each measurement of flow rate used in Eq. FF-1 [§98.326(f)]Dugout Fan
Date of each measurement of flow rate used in Eq. FF-1 (MM/DD/YYYY) [§98.326(f)]2020-02-18
Dates when continuous monitoring equipment for the flow rate is not properly functioning, if applicable (MM/DD/YYYY) [§98.326(n)] - Start date
Stop date
Method used for concentration [§98.326(g), (r), (s)]Monitored using 98.324(b)(1)
C - Quarterly CH4 concentration used in Eq. FF-1 (volume %) [§98.326(g)]0.0254
Was Eq. FF-9 required to calculate CH4 concentration? [§98.326(o)]No
If yes, provide the gaseous organic concentration correction factor, used in Eq. FF-9 [§98.326(o)]
Length of time that substitute data are used for the quarterly CH4 concentration (hours) [§98.3(c)(8), §98.326(g)]0
Location of each measurement of concentration [§98.326(g)]Dugout Fan
Date of each measurement of concentration (MM/DD/YYYY) [§98.326(g)]2020-02-18
Dates when continuous monitoring equipment for the concentration is not properly functioning, if applicable (MM/DD/YYYY) [§98.326(n)] - Start date
Stop date
T - Temperature used in Eq. FF-1 (°R) [§98.326(o)]510.67
Length of time that substitute data are used for the temperature used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(o)]0
P - Absolute Pressure used in Eq. FF-1 (atm) [§98.326(o)]0.78
Length of time that substitute data are used for the pressure used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(o)]0
Were the Quarterly Ventilation Flow Rate and Quarterly CH4 Concentration measured on the same basis? [§98.326(f)-(g)]Flow rate was measured on a wet basis and CH4 concentration was measured on a dry basis
Was a flow meter used? [§98.326(f)-(g)]A flow meter was not used
fH2O - Moisture content used in Eq. FF-1 (cubic feet water per cubic feet biogas) [§98.326(o)]0.009
Length of time that substitute data are used for the moisture content used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(o)]0
Moisture correction factor used in Eq. FF-1 [§98.326(o)]0.991
Length of time that substitute data are used for the moisture correction factor used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(o)]0
CH4V - Quarterly CH4 liberated from ventilation monitoring point (MT CH4) [§98.326(a)] --- Output of Eq. FF-1434.21
File name of MSHA report used to report quarterly CH4 concentration and volumetric flow rate [§98.326(a)]
Ventilation Monitoring Point that corresponds to centralized monitoring point or individual shaft from previous tab [§98.326(l)]Dugout Fan
Quarter2
Dates where active ventilation of mining operations is taking place (MM/DD/YYYY) [§98.326(l)] - Start date2020-04-01
Stop date2020-06-30
Method used for flow rate [§98.326(f), (r), (s)]Monitored using 98.324(b)(1)
V - Quarterly volumetric flow rate used in Eq. FF-1 (acfm or scfm per selection in column A7) [§98.326(f)]953350
Specify units for parameter V, quarterly volumetric flow rate [§98.326(f)]acfm
Length of time that substitute data are used for the quarterly volumetric flow rate used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(f)]0
Location of each measurement of flow rate used in Eq. FF-1 [§98.326(f)]Dugout Fan
Date of each measurement of flow rate used in Eq. FF-1 (MM/DD/YYYY) [§98.326(f)]2020-06-08
Dates when continuous monitoring equipment for the flow rate is not properly functioning, if applicable (MM/DD/YYYY) [§98.326(n)] - Start date
Stop date
Method used for concentration [§98.326(g), (r), (s)]Monitored using 98.324(b)(1)
C - Quarterly CH4 concentration used in Eq. FF-1 (volume %) [§98.326(g)]0.0512
Was Eq. FF-9 required to calculate CH4 concentration? [§98.326(o)]No
If yes, provide the gaseous organic concentration correction factor, used in Eq. FF-9 [§98.326(o)]
Length of time that substitute data are used for the quarterly CH4 concentration (hours) [§98.3(c)(8), §98.326(g)]0
Location of each measurement of concentration [§98.326(g)]Dugout Fan
Date of each measurement of concentration (MM/DD/YYYY) [§98.326(g)]2020-06-08
Dates when continuous monitoring equipment for the concentration is not properly functioning, if applicable (MM/DD/YYYY) [§98.326(n)] - Start date
Stop date
T - Temperature used in Eq. FF-1 (°R) [§98.326(o)]512.67
Length of time that substitute data are used for the temperature used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(o)]0
P - Absolute Pressure used in Eq. FF-1 (atm) [§98.326(o)]0.78
Length of time that substitute data are used for the pressure used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(o)]0
Were the Quarterly Ventilation Flow Rate and Quarterly CH4 Concentration measured on the same basis? [§98.326(f)-(g)]Flow rate was measured on a wet basis and CH4 concentration was measured on a dry basis
Was a flow meter used? [§98.326(f)-(g)]A flow meter was not used
fH2O - Moisture content used in Eq. FF-1 (cubic feet water per cubic feet biogas) [§98.326(o)]0.0124
Length of time that substitute data are used for the moisture content used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(o)]0
Moisture correction factor used in Eq. FF-1 [§98.326(o)]0.9876
Length of time that substitute data are used for the moisture correction factor used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(o)]0
CH4V - Quarterly CH4 liberated from ventilation monitoring point (MT CH4) [§98.326(a)] --- Output of Eq. FF-1958.26
File name of MSHA report used to report quarterly CH4 concentration and volumetric flow rate [§98.326(a)]


EmissionsSummaryFFDetails:


TotalResultForMethaneLiberatedFromVentilationSystemsRowDetails:
QuarterQuarter 1 (Jan-Mar)
CH4VTotal - Facility total quarterly CH4 liberated from ventilation systems according to Eq. FF-2 (MT CH4, unrounded) [§98.3(c)(4)(iii)] --- Calculated Result 434.21 N
QuarterQuarter 2 (Apr-Jun)
CH4VTotal - Facility total quarterly CH4 liberated from ventilation systems according to Eq. FF-2 (MT CH4, unrounded) [§98.3(c)(4)(iii)] --- Calculated Result 958.26 N
QuarterQuarter 3 (Jul-Sep)
CH4VTotal - Facility total quarterly CH4 liberated from ventilation systems according to Eq. FF-2 (MT CH4, unrounded) [§98.3(c)(4)(iii)] --- Calculated Result 0 N
QuarterQuarter 4 (Oct-Dec)
CH4VTotal - Facility total quarterly CH4 liberated from ventilation systems according to Eq. FF-2 (MT CH4, unrounded) [§98.3(c)(4)(iii)] --- Calculated Result 0 N


TotalResultForMethaneLiberatedFromMonitoringPointsRowDetails:
QuarterQuarter 1 (Jan-Mar)
CH4DTotal - Facility total quarterly CH4 liberated from all degasification monitoring points according to Eq. FF-4 (MT CH4, unrounded) [§98.3(c)(4)(iii)] --- Calculated Result 0 N
QuarterQuarter 2 (Apr-Jun)
CH4DTotal - Facility total quarterly CH4 liberated from all degasification monitoring points according to Eq. FF-4 (MT CH4, unrounded) [§98.3(c)(4)(iii)] --- Calculated Result 0 N
QuarterQuarter 3 (Jul-Sep)
CH4DTotal - Facility total quarterly CH4 liberated from all degasification monitoring points according to Eq. FF-4 (MT CH4, unrounded) [§98.3(c)(4)(iii)] --- Calculated Result 0 N
QuarterQuarter 4 (Oct-Dec)
CH4DTotal - Facility total quarterly CH4 liberated from all degasification monitoring points according to Eq. FF-4 (MT CH4, unrounded) [§98.3(c)(4)(iii)] --- Calculated Result 0 N


TotalQuarterlyMethaneDestroyedAtMineTransportedOffsiteRowDetails:
QuarterQuarter 1 (Jan-Mar)
CH4DestroyedTotal - Facility total quarterly CH4 destroyed at the mine and transported offsite according to Eq. FF-6 (MT CH4, unrounded) [§98.3(c)(4)(iii)] --- Calculated Result 0 N
QuarterQuarter 2 (Apr-Jun)
CH4DestroyedTotal - Facility total quarterly CH4 destroyed at the mine and transported offsite according to Eq. FF-6 (MT CH4, unrounded) [§98.3(c)(4)(iii)] --- Calculated Result 0 N
QuarterQuarter 3 (Jul-Sep)
CH4DestroyedTotal - Facility total quarterly CH4 destroyed at the mine and transported offsite according to Eq. FF-6 (MT CH4, unrounded) [§98.3(c)(4)(iii)] --- Calculated Result 0 N
QuarterQuarter 4 (Oct-Dec)
CH4DestroyedTotal - Facility total quarterly CH4 destroyed at the mine and transported offsite according to Eq. FF-6 (MT CH4, unrounded) [§98.3(c)(4)(iii)] --- Calculated Result 0 N


TotalQuarterlyNetMethaneEmissionsRowDetails:
QuarterQuarter 1 (Jan-Mar)
CH4VTotal - Facility total quarterly CH4 liberated from ventilation systems (MT CH4, rounded) [§98.3(c)(4)(iii)] --- [D2=(A2 or A4)]434.21
CH4DTotal - Facility total quarterly CH4 liberated from all degasification monitoring points (MT CH4, rounded) [§98.3(c)(4)(iii)] --- [D3=(B2 or B4)]0
CH4DestroyedTotal - Facility total quarterly CH4 destroyed at the mine and transported offsite (MT CH4, rounded) [§98.3(c)(4)(iii)] --- [D4=(C2 or C4)]0
CH4emitted(net) - Facility total quarterly net CH4 emissions to the atmosphere from the mine according to Eq. FF-7 (MT CH4, rounded) [§98.3(c)(4)(iii)] --- [D5=D2+D3-D4]434.21
QuarterQuarter 2 (Apr-Jun)
CH4VTotal - Facility total quarterly CH4 liberated from ventilation systems (MT CH4, rounded) [§98.3(c)(4)(iii)] --- [D2=(A2 or A4)]958.26
CH4DTotal - Facility total quarterly CH4 liberated from all degasification monitoring points (MT CH4, rounded) [§98.3(c)(4)(iii)] --- [D3=(B2 or B4)]0
CH4DestroyedTotal - Facility total quarterly CH4 destroyed at the mine and transported offsite (MT CH4, rounded) [§98.3(c)(4)(iii)] --- [D4=(C2 or C4)]0
CH4emitted(net) - Facility total quarterly net CH4 emissions to the atmosphere from the mine according to Eq. FF-7 (MT CH4, rounded) [§98.3(c)(4)(iii)] --- [D5=D2+D3-D4]958.26
QuarterQuarter 3 (Jul-Sep)
CH4VTotal - Facility total quarterly CH4 liberated from ventilation systems (MT CH4, rounded) [§98.3(c)(4)(iii)] --- [D2=(A2 or A4)]0
CH4DTotal - Facility total quarterly CH4 liberated from all degasification monitoring points (MT CH4, rounded) [§98.3(c)(4)(iii)] --- [D3=(B2 or B4)]0
CH4DestroyedTotal - Facility total quarterly CH4 destroyed at the mine and transported offsite (MT CH4, rounded) [§98.3(c)(4)(iii)] --- [D4=(C2 or C4)]0
CH4emitted(net) - Facility total quarterly net CH4 emissions to the atmosphere from the mine according to Eq. FF-7 (MT CH4, rounded) [§98.3(c)(4)(iii)] --- [D5=D2+D3-D4]0
QuarterQuarter 4 (Oct-Dec)
CH4VTotal - Facility total quarterly CH4 liberated from ventilation systems (MT CH4, rounded) [§98.3(c)(4)(iii)] --- [D2=(A2 or A4)]0
CH4DTotal - Facility total quarterly CH4 liberated from all degasification monitoring points (MT CH4, rounded) [§98.3(c)(4)(iii)] --- [D3=(B2 or B4)]0
CH4DestroyedTotal - Facility total quarterly CH4 destroyed at the mine and transported offsite (MT CH4, rounded) [§98.3(c)(4)(iii)] --- [D4=(C2 or C4)]0
CH4emitted(net) - Facility total quarterly net CH4 emissions to the atmosphere from the mine according to Eq. FF-7 (MT CH4, rounded) [§98.3(c)(4)(iii)] --- [D5=D2+D3-D4]0