Ventilation Monitoring Point that corresponds to centralized monitoring point or individual shaft from previous tab [§98.326(l)] | Battle Run |
Quarter | 1 |
Dates where active ventilation of mining operations is taking place (MM/DD/YYYY) [§98.326(l)] - Start date | 2020-01-01 |
Stop date | 2020-03-31 |
Method used for flow rate [§98.326(f), (r), (s)] | Monitored using 98.324(b)(2) |
V - Quarterly volumetric flow rate used in Eq. FF-1 (acfm or scfm per selection in column A7) [§98.326(f)] | 404264 |
Specify units for parameter V, quarterly volumetric flow rate [§98.326(f)] | acfm |
Length of time that substitute data are used for the quarterly volumetric flow rate used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(f)] | |
Location of each measurement of flow rate used in Eq. FF-1 [§98.326(f)] | Battle Run |
Date of each measurement of flow rate used in Eq. FF-1 (MM/DD/YYYY) [§98.326(f)] | 2020-01-14 |
Dates when continuous monitoring equipment for the flow rate is not properly functioning, if applicable (MM/DD/YYYY) [§98.326(n)] - Start date | |
Stop date | |
Method used for concentration [§98.326(g), (r), (s)] | Monitored using 98.324(b)(2) |
C - Quarterly CH4 concentration used in Eq. FF-1 (volume %) [§98.326(g)] | 0.103 |
Was Eq. FF-9 required to calculate CH4 concentration? [§98.326(o)] | No |
If yes, provide the gaseous organic concentration correction factor, used in Eq. FF-9 [§98.326(o)] | |
Length of time that substitute data are used for the quarterly CH4 concentration (hours) [§98.3(c)(8), §98.326(g)] | |
Location of each measurement of concentration [§98.326(g)] | Battle Run |
Date of each measurement of concentration (MM/DD/YYYY) [§98.326(g)] | 2020-01-14 |
Dates when continuous monitoring equipment for the concentration is not properly functioning, if applicable (MM/DD/YYYY) [§98.326(n)] - Start date | |
Stop date | |
T - Temperature used in Eq. FF-1 (°R) [§98.326(o)] | 511.67 |
Length of time that substitute data are used for the temperature used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(o)] | |
P - Absolute Pressure used in Eq. FF-1 (atm) [§98.326(o)] | 0.96 |
Length of time that substitute data are used for the pressure used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(o)] | |
Were the Quarterly Ventilation Flow Rate and Quarterly CH4 Concentration measured on the same basis? [§98.326(f)-(g)] | Flow rate and CH4 concentration were measured on a dry basis |
Was a flow meter used? [§98.326(f)-(g)] | A flow meter was used and the flow meter automatically corrected for moisture content |
fH2O - Moisture content used in Eq. FF-1 (cubic feet water per cubic feet biogas) [§98.326(o)] | |
Length of time that substitute data are used for the moisture content used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(o)] | |
Moisture correction factor used in Eq. FF-1 [§98.326(o)] | 1 |
Length of time that substitute data are used for the moisture correction factor used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(o)] | |
CH4V - Quarterly CH4 liberated from ventilation monitoring point (MT CH4) [§98.326(a)] --- Output of Eq. FF-1 | 581.35 |
File name of MSHA report used to report quarterly CH4 concentration and volumetric flow rate [§98.326(a)] | |
Ventilation Monitoring Point that corresponds to centralized monitoring point or individual shaft from previous tab [§98.326(l)] | Wagner Shaft |
Quarter | 1 |
Dates where active ventilation of mining operations is taking place (MM/DD/YYYY) [§98.326(l)] - Start date | 2020-01-01 |
Stop date | 2020-03-31 |
Method used for flow rate [§98.326(f), (r), (s)] | Monitored using 98.324(b)(2) |
V - Quarterly volumetric flow rate used in Eq. FF-1 (acfm or scfm per selection in column A7) [§98.326(f)] | 219259 |
Specify units for parameter V, quarterly volumetric flow rate [§98.326(f)] | acfm |
Length of time that substitute data are used for the quarterly volumetric flow rate used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(f)] | |
Location of each measurement of flow rate used in Eq. FF-1 [§98.326(f)] | Wagner Shaft |
Date of each measurement of flow rate used in Eq. FF-1 (MM/DD/YYYY) [§98.326(f)] | 2020-01-22 |
Dates when continuous monitoring equipment for the flow rate is not properly functioning, if applicable (MM/DD/YYYY) [§98.326(n)] - Start date | |
Stop date | |
Method used for concentration [§98.326(g), (r), (s)] | Monitored using 98.324(b)(2) |
C - Quarterly CH4 concentration used in Eq. FF-1 (volume %) [§98.326(g)] | 0.914 |
Was Eq. FF-9 required to calculate CH4 concentration? [§98.326(o)] | No |
If yes, provide the gaseous organic concentration correction factor, used in Eq. FF-9 [§98.326(o)] | |
Length of time that substitute data are used for the quarterly CH4 concentration (hours) [§98.3(c)(8), §98.326(g)] | |
Location of each measurement of concentration [§98.326(g)] | Wagner Shaft |
Date of each measurement of concentration (MM/DD/YYYY) [§98.326(g)] | 2020-01-22 |
Dates when continuous monitoring equipment for the concentration is not properly functioning, if applicable (MM/DD/YYYY) [§98.326(n)] - Start date | |
Stop date | |
T - Temperature used in Eq. FF-1 (°R) [§98.326(o)] | 494.67 |
Length of time that substitute data are used for the temperature used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(o)] | |
P - Absolute Pressure used in Eq. FF-1 (atm) [§98.326(o)] | 0.97 |
Length of time that substitute data are used for the pressure used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(o)] | |
Were the Quarterly Ventilation Flow Rate and Quarterly CH4 Concentration measured on the same basis? [§98.326(f)-(g)] | Flow rate and CH4 concentration were measured on a dry basis |
Was a flow meter used? [§98.326(f)-(g)] | A flow meter was used and the flow meter automatically corrected for moisture content |
fH2O - Moisture content used in Eq. FF-1 (cubic feet water per cubic feet biogas) [§98.326(o)] | |
Length of time that substitute data are used for the moisture content used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(o)] | |
Moisture correction factor used in Eq. FF-1 [§98.326(o)] | 1 |
Length of time that substitute data are used for the moisture correction factor used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(o)] | |
CH4V - Quarterly CH4 liberated from ventilation monitoring point (MT CH4) [§98.326(a)] --- Output of Eq. FF-1 | 5066.9 |
File name of MSHA report used to report quarterly CH4 concentration and volumetric flow rate [§98.326(a)] | |
Ventilation Monitoring Point that corresponds to centralized monitoring point or individual shaft from previous tab [§98.326(l)] | Winters Shaft |
Quarter | 1 |
Dates where active ventilation of mining operations is taking place (MM/DD/YYYY) [§98.326(l)] - Start date | 2020-01-01 |
Stop date | 2020-03-31 |
Method used for flow rate [§98.326(f), (r), (s)] | Monitored using 98.324(b)(2) |
V - Quarterly volumetric flow rate used in Eq. FF-1 (acfm or scfm per selection in column A7) [§98.326(f)] | 740070 |
Specify units for parameter V, quarterly volumetric flow rate [§98.326(f)] | acfm |
Length of time that substitute data are used for the quarterly volumetric flow rate used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(f)] | |
Location of each measurement of flow rate used in Eq. FF-1 [§98.326(f)] | Winters Shaft |
Date of each measurement of flow rate used in Eq. FF-1 (MM/DD/YYYY) [§98.326(f)] | 2020-01-14 |
Dates when continuous monitoring equipment for the flow rate is not properly functioning, if applicable (MM/DD/YYYY) [§98.326(n)] - Start date | |
Stop date | |
Method used for concentration [§98.326(g), (r), (s)] | Monitored using 98.324(b)(2) |
C - Quarterly CH4 concentration used in Eq. FF-1 (volume %) [§98.326(g)] | 0.052 |
Was Eq. FF-9 required to calculate CH4 concentration? [§98.326(o)] | No |
If yes, provide the gaseous organic concentration correction factor, used in Eq. FF-9 [§98.326(o)] | |
Length of time that substitute data are used for the quarterly CH4 concentration (hours) [§98.3(c)(8), §98.326(g)] | |
Location of each measurement of concentration [§98.326(g)] | Winters Shaft |
Date of each measurement of concentration (MM/DD/YYYY) [§98.326(g)] | 2020-01-14 |
Dates when continuous monitoring equipment for the concentration is not properly functioning, if applicable (MM/DD/YYYY) [§98.326(n)] - Start date | |
Stop date | |
T - Temperature used in Eq. FF-1 (°R) [§98.326(o)] | 511.67 |
Length of time that substitute data are used for the temperature used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(o)] | |
P - Absolute Pressure used in Eq. FF-1 (atm) [§98.326(o)] | 0.96 |
Length of time that substitute data are used for the pressure used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(o)] | |
Were the Quarterly Ventilation Flow Rate and Quarterly CH4 Concentration measured on the same basis? [§98.326(f)-(g)] | Flow rate and CH4 concentration were measured on a dry basis |
Was a flow meter used? [§98.326(f)-(g)] | A flow meter was used and the flow meter automatically corrected for moisture content |
fH2O - Moisture content used in Eq. FF-1 (cubic feet water per cubic feet biogas) [§98.326(o)] | |
Length of time that substitute data are used for the moisture content used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(o)] | |
Moisture correction factor used in Eq. FF-1 [§98.326(o)] | 1 |
Length of time that substitute data are used for the moisture correction factor used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(o)] | |
CH4V - Quarterly CH4 liberated from ventilation monitoring point (MT CH4) [§98.326(a)] --- Output of Eq. FF-1 | 1076.26 |
File name of MSHA report used to report quarterly CH4 concentration and volumetric flow rate [§98.326(a)] | |
Ventilation Monitoring Point that corresponds to centralized monitoring point or individual shaft from previous tab [§98.326(l)] | Battle Run |
Quarter | 2 |
Dates where active ventilation of mining operations is taking place (MM/DD/YYYY) [§98.326(l)] - Start date | 2020-04-01 |
Stop date | 2020-06-30 |
Method used for flow rate [§98.326(f), (r), (s)] | Monitored using 98.324(b)(2) |
V - Quarterly volumetric flow rate used in Eq. FF-1 (acfm or scfm per selection in column A7) [§98.326(f)] | 482370 |
Specify units for parameter V, quarterly volumetric flow rate [§98.326(f)] | acfm |
Length of time that substitute data are used for the quarterly volumetric flow rate used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(f)] | |
Location of each measurement of flow rate used in Eq. FF-1 [§98.326(f)] | Battle Run |
Date of each measurement of flow rate used in Eq. FF-1 (MM/DD/YYYY) [§98.326(f)] | 2020-04-06 |
Dates when continuous monitoring equipment for the flow rate is not properly functioning, if applicable (MM/DD/YYYY) [§98.326(n)] - Start date | |
Stop date | |
Method used for concentration [§98.326(g), (r), (s)] | Monitored using 98.324(b)(2) |
C - Quarterly CH4 concentration used in Eq. FF-1 (volume %) [§98.326(g)] | 0.106 |
Was Eq. FF-9 required to calculate CH4 concentration? [§98.326(o)] | No |
If yes, provide the gaseous organic concentration correction factor, used in Eq. FF-9 [§98.326(o)] | |
Length of time that substitute data are used for the quarterly CH4 concentration (hours) [§98.3(c)(8), §98.326(g)] | |
Location of each measurement of concentration [§98.326(g)] | Battle Run |
Date of each measurement of concentration (MM/DD/YYYY) [§98.326(g)] | 2020-04-06 |
Dates when continuous monitoring equipment for the concentration is not properly functioning, if applicable (MM/DD/YYYY) [§98.326(n)] - Start date | |
Stop date | |
T - Temperature used in Eq. FF-1 (°R) [§98.326(o)] | 520.67 |
Length of time that substitute data are used for the temperature used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(o)] | |
P - Absolute Pressure used in Eq. FF-1 (atm) [§98.326(o)] | 0.958 |
Length of time that substitute data are used for the pressure used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(o)] | |
Were the Quarterly Ventilation Flow Rate and Quarterly CH4 Concentration measured on the same basis? [§98.326(f)-(g)] | Flow rate and CH4 concentration were measured on a dry basis |
Was a flow meter used? [§98.326(f)-(g)] | A flow meter was used and the flow meter automatically corrected for moisture content |
fH2O - Moisture content used in Eq. FF-1 (cubic feet water per cubic feet biogas) [§98.326(o)] | |
Length of time that substitute data are used for the moisture content used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(o)] | |
Moisture correction factor used in Eq. FF-1 [§98.326(o)] | 1 |
Length of time that substitute data are used for the moisture correction factor used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(o)] | |
CH4V - Quarterly CH4 liberated from ventilation monitoring point (MT CH4) [§98.326(a)] --- Output of Eq. FF-1 | 789.77 |
File name of MSHA report used to report quarterly CH4 concentration and volumetric flow rate [§98.326(a)] | |
Ventilation Monitoring Point that corresponds to centralized monitoring point or individual shaft from previous tab [§98.326(l)] | Wagner Shaft |
Quarter | 2 |
Dates where active ventilation of mining operations is taking place (MM/DD/YYYY) [§98.326(l)] - Start date | 2020-04-01 |
Stop date | 2020-06-30 |
Method used for flow rate [§98.326(f), (r), (s)] | Monitored using 98.324(b)(2) |
V - Quarterly volumetric flow rate used in Eq. FF-1 (acfm or scfm per selection in column A7) [§98.326(f)] | 225035 |
Specify units for parameter V, quarterly volumetric flow rate [§98.326(f)] | acfm |
Length of time that substitute data are used for the quarterly volumetric flow rate used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(f)] | |
Location of each measurement of flow rate used in Eq. FF-1 [§98.326(f)] | Wagner Shaft |
Date of each measurement of flow rate used in Eq. FF-1 (MM/DD/YYYY) [§98.326(f)] | 2020-04-15 |
Dates when continuous monitoring equipment for the flow rate is not properly functioning, if applicable (MM/DD/YYYY) [§98.326(n)] - Start date | |
Stop date | |
Method used for concentration [§98.326(g), (r), (s)] | Monitored using 98.324(b)(2) |
C - Quarterly CH4 concentration used in Eq. FF-1 (volume %) [§98.326(g)] | 0.976 |
Was Eq. FF-9 required to calculate CH4 concentration? [§98.326(o)] | No |
If yes, provide the gaseous organic concentration correction factor, used in Eq. FF-9 [§98.326(o)] | |
Length of time that substitute data are used for the quarterly CH4 concentration (hours) [§98.3(c)(8), §98.326(g)] | |
Location of each measurement of concentration [§98.326(g)] | Wagner Shaft |
Date of each measurement of concentration (MM/DD/YYYY) [§98.326(g)] | 2020-04-15 |
Dates when continuous monitoring equipment for the concentration is not properly functioning, if applicable (MM/DD/YYYY) [§98.326(n)] - Start date | |
Stop date | |
T - Temperature used in Eq. FF-1 (°R) [§98.326(o)] | 520.67 |
Length of time that substitute data are used for the temperature used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(o)] | |
P - Absolute Pressure used in Eq. FF-1 (atm) [§98.326(o)] | 0.95651 |
Length of time that substitute data are used for the pressure used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(o)] | |
Were the Quarterly Ventilation Flow Rate and Quarterly CH4 Concentration measured on the same basis? [§98.326(f)-(g)] | Flow rate and CH4 concentration were measured on a dry basis |
Was a flow meter used? [§98.326(f)-(g)] | A flow meter was used and the flow meter automatically corrected for moisture content |
fH2O - Moisture content used in Eq. FF-1 (cubic feet water per cubic feet biogas) [§98.326(o)] | |
Length of time that substitute data are used for the moisture content used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(o)] | |
Moisture correction factor used in Eq. FF-1 [§98.326(o)] | 1 |
Length of time that substitute data are used for the moisture correction factor used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(o)] | |
CH4V - Quarterly CH4 liberated from ventilation monitoring point (MT CH4) [§98.326(a)] --- Output of Eq. FF-1 | 5411.75 |
File name of MSHA report used to report quarterly CH4 concentration and volumetric flow rate [§98.326(a)] | |
Ventilation Monitoring Point that corresponds to centralized monitoring point or individual shaft from previous tab [§98.326(l)] | Winters Shaft |
Quarter | 2 |
Dates where active ventilation of mining operations is taking place (MM/DD/YYYY) [§98.326(l)] - Start date | 2020-04-01 |
Stop date | 2020-06-30 |
Method used for flow rate [§98.326(f), (r), (s)] | Monitored using 98.324(b)(2) |
V - Quarterly volumetric flow rate used in Eq. FF-1 (acfm or scfm per selection in column A7) [§98.326(f)] | 944597 |
Specify units for parameter V, quarterly volumetric flow rate [§98.326(f)] | acfm |
Length of time that substitute data are used for the quarterly volumetric flow rate used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(f)] | |
Location of each measurement of flow rate used in Eq. FF-1 [§98.326(f)] | Winters Shaft |
Date of each measurement of flow rate used in Eq. FF-1 (MM/DD/YYYY) [§98.326(f)] | 2020-04-02 |
Dates when continuous monitoring equipment for the flow rate is not properly functioning, if applicable (MM/DD/YYYY) [§98.326(n)] - Start date | |
Stop date | |
Method used for concentration [§98.326(g), (r), (s)] | Monitored using 98.324(b)(2) |
C - Quarterly CH4 concentration used in Eq. FF-1 (volume %) [§98.326(g)] | 0.076 |
Was Eq. FF-9 required to calculate CH4 concentration? [§98.326(o)] | No |
If yes, provide the gaseous organic concentration correction factor, used in Eq. FF-9 [§98.326(o)] | |
Length of time that substitute data are used for the quarterly CH4 concentration (hours) [§98.3(c)(8), §98.326(g)] | |
Location of each measurement of concentration [§98.326(g)] | Winters Shaft |
Date of each measurement of concentration (MM/DD/YYYY) [§98.326(g)] | 2020-04-02 |
Dates when continuous monitoring equipment for the concentration is not properly functioning, if applicable (MM/DD/YYYY) [§98.326(n)] - Start date | |
Stop date | |
T - Temperature used in Eq. FF-1 (°R) [§98.326(o)] | 511.67 |
Length of time that substitute data are used for the temperature used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(o)] | |
P - Absolute Pressure used in Eq. FF-1 (atm) [§98.326(o)] | 0.959 |
Length of time that substitute data are used for the pressure used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(o)] | |
Were the Quarterly Ventilation Flow Rate and Quarterly CH4 Concentration measured on the same basis? [§98.326(f)-(g)] | Flow rate and CH4 concentration were measured on a dry basis |
Was a flow meter used? [§98.326(f)-(g)] | A flow meter was used and the flow meter automatically corrected for moisture content |
fH2O - Moisture content used in Eq. FF-1 (cubic feet water per cubic feet biogas) [§98.326(o)] | |
Length of time that substitute data are used for the moisture content used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(o)] | |
Moisture correction factor used in Eq. FF-1 [§98.326(o)] | 1 |
Length of time that substitute data are used for the moisture correction factor used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(o)] | |
CH4V - Quarterly CH4 liberated from ventilation monitoring point (MT CH4) [§98.326(a)] --- Output of Eq. FF-1 | 1809.19 |
File name of MSHA report used to report quarterly CH4 concentration and volumetric flow rate [§98.326(a)] | |
Ventilation Monitoring Point that corresponds to centralized monitoring point or individual shaft from previous tab [§98.326(l)] | Battle Run |
Quarter | 3 |
Dates where active ventilation of mining operations is taking place (MM/DD/YYYY) [§98.326(l)] - Start date | 2020-07-01 |
Stop date | 2020-09-30 |
Method used for flow rate [§98.326(f), (r), (s)] | Monitored using 98.324(b)(2) |
V - Quarterly volumetric flow rate used in Eq. FF-1 (acfm or scfm per selection in column A7) [§98.326(f)] | 466153 |
Specify units for parameter V, quarterly volumetric flow rate [§98.326(f)] | acfm |
Length of time that substitute data are used for the quarterly volumetric flow rate used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(f)] | |
Location of each measurement of flow rate used in Eq. FF-1 [§98.326(f)] | Battle Run |
Date of each measurement of flow rate used in Eq. FF-1 (MM/DD/YYYY) [§98.326(f)] | 2020-07-07 |
Dates when continuous monitoring equipment for the flow rate is not properly functioning, if applicable (MM/DD/YYYY) [§98.326(n)] - Start date | |
Stop date | |
Method used for concentration [§98.326(g), (r), (s)] | Monitored using 98.324(b)(2) |
C - Quarterly CH4 concentration used in Eq. FF-1 (volume %) [§98.326(g)] | 0.093 |
Was Eq. FF-9 required to calculate CH4 concentration? [§98.326(o)] | No |
If yes, provide the gaseous organic concentration correction factor, used in Eq. FF-9 [§98.326(o)] | |
Length of time that substitute data are used for the quarterly CH4 concentration (hours) [§98.3(c)(8), §98.326(g)] | |
Location of each measurement of concentration [§98.326(g)] | Battle Run |
Date of each measurement of concentration (MM/DD/YYYY) [§98.326(g)] | 2020-07-07 |
Dates when continuous monitoring equipment for the concentration is not properly functioning, if applicable (MM/DD/YYYY) [§98.326(n)] - Start date | |
Stop date | |
T - Temperature used in Eq. FF-1 (°R) [§98.326(o)] | 549.67 |
Length of time that substitute data are used for the temperature used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(o)] | |
P - Absolute Pressure used in Eq. FF-1 (atm) [§98.326(o)] | 0.959 |
Length of time that substitute data are used for the pressure used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(o)] | |
Were the Quarterly Ventilation Flow Rate and Quarterly CH4 Concentration measured on the same basis? [§98.326(f)-(g)] | Flow rate and CH4 concentration were measured on a dry basis |
Was a flow meter used? [§98.326(f)-(g)] | A flow meter was used and the flow meter automatically corrected for moisture content |
fH2O - Moisture content used in Eq. FF-1 (cubic feet water per cubic feet biogas) [§98.326(o)] | |
Length of time that substitute data are used for the moisture content used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(o)] | |
Moisture correction factor used in Eq. FF-1 [§98.326(o)] | 1 |
Length of time that substitute data are used for the moisture correction factor used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(o)] | |
CH4V - Quarterly CH4 liberated from ventilation monitoring point (MT CH4) [§98.326(a)] --- Output of Eq. FF-1 | 712.75 |
File name of MSHA report used to report quarterly CH4 concentration and volumetric flow rate [§98.326(a)] | |
Ventilation Monitoring Point that corresponds to centralized monitoring point or individual shaft from previous tab [§98.326(l)] | Wagner Shaft |
Quarter | 3 |
Dates where active ventilation of mining operations is taking place (MM/DD/YYYY) [§98.326(l)] - Start date | 2020-07-01 |
Stop date | 2020-09-30 |
Method used for flow rate [§98.326(f), (r), (s)] | Monitored using 98.324(b)(2) |
V - Quarterly volumetric flow rate used in Eq. FF-1 (acfm or scfm per selection in column A7) [§98.326(f)] | 252595 |
Specify units for parameter V, quarterly volumetric flow rate [§98.326(f)] | acfm |
Length of time that substitute data are used for the quarterly volumetric flow rate used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(f)] | |
Location of each measurement of flow rate used in Eq. FF-1 [§98.326(f)] | Wagner Shaft |
Date of each measurement of flow rate used in Eq. FF-1 (MM/DD/YYYY) [§98.326(f)] | 2020-07-23 |
Dates when continuous monitoring equipment for the flow rate is not properly functioning, if applicable (MM/DD/YYYY) [§98.326(n)] - Start date | |
Stop date | |
Method used for concentration [§98.326(g), (r), (s)] | Monitored using 98.324(b)(2) |
C - Quarterly CH4 concentration used in Eq. FF-1 (volume %) [§98.326(g)] | 0.927 |
Was Eq. FF-9 required to calculate CH4 concentration? [§98.326(o)] | No |
If yes, provide the gaseous organic concentration correction factor, used in Eq. FF-9 [§98.326(o)] | |
Length of time that substitute data are used for the quarterly CH4 concentration (hours) [§98.3(c)(8), §98.326(g)] | |
Location of each measurement of concentration [§98.326(g)] | Wagner Shaft |
Date of each measurement of concentration (MM/DD/YYYY) [§98.326(g)] | 2020-07-23 |
Dates when continuous monitoring equipment for the concentration is not properly functioning, if applicable (MM/DD/YYYY) [§98.326(n)] - Start date | |
Stop date | |
T - Temperature used in Eq. FF-1 (°R) [§98.326(o)] | 537.67 |
Length of time that substitute data are used for the temperature used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(o)] | |
P - Absolute Pressure used in Eq. FF-1 (atm) [§98.326(o)] | 0.962 |
Length of time that substitute data are used for the pressure used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(o)] | |
Were the Quarterly Ventilation Flow Rate and Quarterly CH4 Concentration measured on the same basis? [§98.326(f)-(g)] | Flow rate and CH4 concentration were measured on a dry basis |
Was a flow meter used? [§98.326(f)-(g)] | A flow meter was used and the flow meter automatically corrected for moisture content |
fH2O - Moisture content used in Eq. FF-1 (cubic feet water per cubic feet biogas) [§98.326(o)] | |
Length of time that substitute data are used for the moisture content used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(o)] | |
Moisture correction factor used in Eq. FF-1 [§98.326(o)] | 1 |
Length of time that substitute data are used for the moisture correction factor used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(o)] | |
CH4V - Quarterly CH4 liberated from ventilation monitoring point (MT CH4) [§98.326(a)] --- Output of Eq. FF-1 | 5441.26 |
File name of MSHA report used to report quarterly CH4 concentration and volumetric flow rate [§98.326(a)] | |
Ventilation Monitoring Point that corresponds to centralized monitoring point or individual shaft from previous tab [§98.326(l)] | Winters Shaft |
Quarter | 3 |
Dates where active ventilation of mining operations is taking place (MM/DD/YYYY) [§98.326(l)] - Start date | 2020-07-01 |
Stop date | 2020-09-30 |
Method used for flow rate [§98.326(f), (r), (s)] | Monitored using 98.324(b)(2) |
V - Quarterly volumetric flow rate used in Eq. FF-1 (acfm or scfm per selection in column A7) [§98.326(f)] | 703552 |
Specify units for parameter V, quarterly volumetric flow rate [§98.326(f)] | acfm |
Length of time that substitute data are used for the quarterly volumetric flow rate used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(f)] | |
Location of each measurement of flow rate used in Eq. FF-1 [§98.326(f)] | Winters Shaft |
Date of each measurement of flow rate used in Eq. FF-1 (MM/DD/YYYY) [§98.326(f)] | 2020-07-07 |
Dates when continuous monitoring equipment for the flow rate is not properly functioning, if applicable (MM/DD/YYYY) [§98.326(n)] - Start date | |
Stop date | |
Method used for concentration [§98.326(g), (r), (s)] | Monitored using 98.324(b)(2) |
C - Quarterly CH4 concentration used in Eq. FF-1 (volume %) [§98.326(g)] | 0.069 |
Was Eq. FF-9 required to calculate CH4 concentration? [§98.326(o)] | No |
If yes, provide the gaseous organic concentration correction factor, used in Eq. FF-9 [§98.326(o)] | |
Length of time that substitute data are used for the quarterly CH4 concentration (hours) [§98.3(c)(8), §98.326(g)] | |
Location of each measurement of concentration [§98.326(g)] | Winters Shaft |
Date of each measurement of concentration (MM/DD/YYYY) [§98.326(g)] | 2020-07-07 |
Dates when continuous monitoring equipment for the concentration is not properly functioning, if applicable (MM/DD/YYYY) [§98.326(n)] - Start date | |
Stop date | |
T - Temperature used in Eq. FF-1 (°R) [§98.326(o)] | 549.67 |
Length of time that substitute data are used for the temperature used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(o)] | |
P - Absolute Pressure used in Eq. FF-1 (atm) [§98.326(o)] | 0.959 |
Length of time that substitute data are used for the pressure used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(o)] | |
Were the Quarterly Ventilation Flow Rate and Quarterly CH4 Concentration measured on the same basis? [§98.326(f)-(g)] | Flow rate and CH4 concentration were measured on a dry basis |
Was a flow meter used? [§98.326(f)-(g)] | A flow meter was used and the flow meter automatically corrected for moisture content |
fH2O - Moisture content used in Eq. FF-1 (cubic feet water per cubic feet biogas) [§98.326(o)] | |
Length of time that substitute data are used for the moisture content used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(o)] | |
Moisture correction factor used in Eq. FF-1 [§98.326(o)] | 1 |
Length of time that substitute data are used for the moisture correction factor used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(o)] | |
CH4V - Quarterly CH4 liberated from ventilation monitoring point (MT CH4) [§98.326(a)] --- Output of Eq. FF-1 | 1137.35 |
File name of MSHA report used to report quarterly CH4 concentration and volumetric flow rate [§98.326(a)] | |
Ventilation Monitoring Point that corresponds to centralized monitoring point or individual shaft from previous tab [§98.326(l)] | Battle Run |
Quarter | 4 |
Dates where active ventilation of mining operations is taking place (MM/DD/YYYY) [§98.326(l)] - Start date | 2020-10-01 |
Stop date | 2020-12-31 |
Method used for flow rate [§98.326(f), (r), (s)] | Monitored using 98.324(b)(2) |
V - Quarterly volumetric flow rate used in Eq. FF-1 (acfm or scfm per selection in column A7) [§98.326(f)] | 429858 |
Specify units for parameter V, quarterly volumetric flow rate [§98.326(f)] | acfm |
Length of time that substitute data are used for the quarterly volumetric flow rate used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(f)] | |
Location of each measurement of flow rate used in Eq. FF-1 [§98.326(f)] | Battle Run |
Date of each measurement of flow rate used in Eq. FF-1 (MM/DD/YYYY) [§98.326(f)] | 2020-10-07 |
Dates when continuous monitoring equipment for the flow rate is not properly functioning, if applicable (MM/DD/YYYY) [§98.326(n)] - Start date | |
Stop date | |
Method used for concentration [§98.326(g), (r), (s)] | Monitored using 98.324(b)(2) |
C - Quarterly CH4 concentration used in Eq. FF-1 (volume %) [§98.326(g)] | 0.226 |
Was Eq. FF-9 required to calculate CH4 concentration? [§98.326(o)] | No |
If yes, provide the gaseous organic concentration correction factor, used in Eq. FF-9 [§98.326(o)] | |
Length of time that substitute data are used for the quarterly CH4 concentration (hours) [§98.3(c)(8), §98.326(g)] | |
Location of each measurement of concentration [§98.326(g)] | Battle Run |
Date of each measurement of concentration (MM/DD/YYYY) [§98.326(g)] | 2020-10-07 |
Dates when continuous monitoring equipment for the concentration is not properly functioning, if applicable (MM/DD/YYYY) [§98.326(n)] - Start date | |
Stop date | |
T - Temperature used in Eq. FF-1 (°R) [§98.326(o)] | 531.67 |
Length of time that substitute data are used for the temperature used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(o)] | |
P - Absolute Pressure used in Eq. FF-1 (atm) [§98.326(o)] | 0.961 |
Length of time that substitute data are used for the pressure used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(o)] | |
Were the Quarterly Ventilation Flow Rate and Quarterly CH4 Concentration measured on the same basis? [§98.326(f)-(g)] | Flow rate and CH4 concentration were measured on a dry basis |
Was a flow meter used? [§98.326(f)-(g)] | A flow meter was used and the flow meter automatically corrected for moisture content |
fH2O - Moisture content used in Eq. FF-1 (cubic feet water per cubic feet biogas) [§98.326(o)] | |
Length of time that substitute data are used for the moisture content used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(o)] | |
Moisture correction factor used in Eq. FF-1 [§98.326(o)] | 1 |
Length of time that substitute data are used for the moisture correction factor used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(o)] | |
CH4V - Quarterly CH4 liberated from ventilation monitoring point (MT CH4) [§98.326(a)] --- Output of Eq. FF-1 | 2022.09 |
File name of MSHA report used to report quarterly CH4 concentration and volumetric flow rate [§98.326(a)] | |
Ventilation Monitoring Point that corresponds to centralized monitoring point or individual shaft from previous tab [§98.326(l)] | Wagner Shaft |
Quarter | 4 |
Dates where active ventilation of mining operations is taking place (MM/DD/YYYY) [§98.326(l)] - Start date | 2020-10-01 |
Stop date | 2020-12-31 |
Method used for flow rate [§98.326(f), (r), (s)] | Monitored using 98.324(b)(2) |
V - Quarterly volumetric flow rate used in Eq. FF-1 (acfm or scfm per selection in column A7) [§98.326(f)] | 296643 |
Specify units for parameter V, quarterly volumetric flow rate [§98.326(f)] | acfm |
Length of time that substitute data are used for the quarterly volumetric flow rate used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(f)] | |
Location of each measurement of flow rate used in Eq. FF-1 [§98.326(f)] | Wagner Shaft |
Date of each measurement of flow rate used in Eq. FF-1 (MM/DD/YYYY) [§98.326(f)] | 2020-10-07 |
Dates when continuous monitoring equipment for the flow rate is not properly functioning, if applicable (MM/DD/YYYY) [§98.326(n)] - Start date | |
Stop date | |
Method used for concentration [§98.326(g), (r), (s)] | Monitored using 98.324(b)(2) |
C - Quarterly CH4 concentration used in Eq. FF-1 (volume %) [§98.326(g)] | 0.722 |
Was Eq. FF-9 required to calculate CH4 concentration? [§98.326(o)] | No |
If yes, provide the gaseous organic concentration correction factor, used in Eq. FF-9 [§98.326(o)] | |
Length of time that substitute data are used for the quarterly CH4 concentration (hours) [§98.3(c)(8), §98.326(g)] | |
Location of each measurement of concentration [§98.326(g)] | Wagner Shaft |
Date of each measurement of concentration (MM/DD/YYYY) [§98.326(g)] | 2020-10-07 |
Dates when continuous monitoring equipment for the concentration is not properly functioning, if applicable (MM/DD/YYYY) [§98.326(n)] - Start date | |
Stop date | |
T - Temperature used in Eq. FF-1 (°R) [§98.326(o)] | 531.67 |
Length of time that substitute data are used for the temperature used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(o)] | |
P - Absolute Pressure used in Eq. FF-1 (atm) [§98.326(o)] | 0.961 |
Length of time that substitute data are used for the pressure used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(o)] | |
Were the Quarterly Ventilation Flow Rate and Quarterly CH4 Concentration measured on the same basis? [§98.326(f)-(g)] | Flow rate and CH4 concentration were measured on a dry basis |
Was a flow meter used? [§98.326(f)-(g)] | A flow meter was used and the flow meter automatically corrected for moisture content |
fH2O - Moisture content used in Eq. FF-1 (cubic feet water per cubic feet biogas) [§98.326(o)] | |
Length of time that substitute data are used for the moisture content used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(o)] | |
Moisture correction factor used in Eq. FF-1 [§98.326(o)] | 1 |
Length of time that substitute data are used for the moisture correction factor used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(o)] | |
CH4V - Quarterly CH4 liberated from ventilation monitoring point (MT CH4) [§98.326(a)] --- Output of Eq. FF-1 | 5182.41 |
File name of MSHA report used to report quarterly CH4 concentration and volumetric flow rate [§98.326(a)] | |
Ventilation Monitoring Point that corresponds to centralized monitoring point or individual shaft from previous tab [§98.326(l)] | Winters Shaft |
Quarter | 4 |
Dates where active ventilation of mining operations is taking place (MM/DD/YYYY) [§98.326(l)] - Start date | 2020-10-01 |
Stop date | 2020-12-31 |
Method used for flow rate [§98.326(f), (r), (s)] | Monitored using 98.324(b)(2) |
V - Quarterly volumetric flow rate used in Eq. FF-1 (acfm or scfm per selection in column A7) [§98.326(f)] | 704480 |
Specify units for parameter V, quarterly volumetric flow rate [§98.326(f)] | acfm |
Length of time that substitute data are used for the quarterly volumetric flow rate used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(f)] | |
Location of each measurement of flow rate used in Eq. FF-1 [§98.326(f)] | Winters Shaft |
Date of each measurement of flow rate used in Eq. FF-1 (MM/DD/YYYY) [§98.326(f)] | 2020-10-06 |
Dates when continuous monitoring equipment for the flow rate is not properly functioning, if applicable (MM/DD/YYYY) [§98.326(n)] - Start date | |
Stop date | |
Method used for concentration [§98.326(g), (r), (s)] | Monitored using 98.324(b)(2) |
C - Quarterly CH4 concentration used in Eq. FF-1 (volume %) [§98.326(g)] | 0.083 |
Was Eq. FF-9 required to calculate CH4 concentration? [§98.326(o)] | No |
If yes, provide the gaseous organic concentration correction factor, used in Eq. FF-9 [§98.326(o)] | |
Length of time that substitute data are used for the quarterly CH4 concentration (hours) [§98.3(c)(8), §98.326(g)] | |
Location of each measurement of concentration [§98.326(g)] | Winters Shaft |
Date of each measurement of concentration (MM/DD/YYYY) [§98.326(g)] | 2020-10-06 |
Dates when continuous monitoring equipment for the concentration is not properly functioning, if applicable (MM/DD/YYYY) [§98.326(n)] - Start date | |
Stop date | |
T - Temperature used in Eq. FF-1 (°R) [§98.326(o)] | 522.67 |
Length of time that substitute data are used for the temperature used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(o)] | |
P - Absolute Pressure used in Eq. FF-1 (atm) [§98.326(o)] | 0.964 |
Length of time that substitute data are used for the pressure used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(o)] | |
Were the Quarterly Ventilation Flow Rate and Quarterly CH4 Concentration measured on the same basis? [§98.326(f)-(g)] | Flow rate and CH4 concentration were measured on a dry basis |
Was a flow meter used? [§98.326(f)-(g)] | A flow meter was used and the flow meter automatically corrected for moisture content |
fH2O - Moisture content used in Eq. FF-1 (cubic feet water per cubic feet biogas) [§98.326(o)] | |
Length of time that substitute data are used for the moisture content used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(o)] | |
Moisture correction factor used in Eq. FF-1 [§98.326(o)] | 1 |
Length of time that substitute data are used for the moisture correction factor used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(o)] | |
CH4V - Quarterly CH4 liberated from ventilation monitoring point (MT CH4) [§98.326(a)] --- Output of Eq. FF-1 | 1437.4 |
File name of MSHA report used to report quarterly CH4 concentration and volumetric flow rate [§98.326(a)] | |