Facility Name:TARGA BENEDUM EDWARD JOYCE GAS PROCESSING PLANT
Facility Identifier:
Facility Reporting Year:2020
Facility Location:
Address: 8900 FM 1555
City: Rankin
State: TX
Postal Code: 79778

Facility Site Details:
CO2 equivalent emissions from facility subparts C-II, SS, and TT (metric tons):232,835.51
CO2 equivalent emissions from supplier subparts LL-QQ (metric tons):
Biogenic CO2 emissions from facility subparts C-II, SS, and TT (metric tons):0
Cogeneration Unit Emissions Indicator:N
GHG Report Start Date:2020-01-01
GHG Report End Date:2020-12-31
Description of Changes to Calculation Methodology:
Plant Code Indicator:N
Primary NAICS Code:211130
Second Primary NAICS Code:

Parent Company Details:
Parent Company Name:TARGA RESOURCES CORP
Address:811 Louisiana Street, Suite 2100, Houston,  TX 77002
Percent Ownership Interest:73
Parent Company Name:PIONEER NATURAL RESOURCES CO
Address:5205 N. O'Connor Blvd. Ste. 200, Irving,  TX 75039
Percent Ownership Interest:27

Subpart C: General Stationary Fuel Combustion

Gas Information Details

Gas NameCarbon Dioxide
Gas Quantity43,380.90092 (Metric Tons)
Own Result?

Gas NameBiogenic Carbon dioxide
Gas Quantity0 (Metric Tons)
Own Result?

Gas NameMethane
Gas Quantity0.817582 (Metric Tons)
Own Result?

Gas NameNitrous Oxide
Gas Quantity0.081758 (Metric Tons)
Own Result?

Unit Details:
Unit Name : GP-ENGINES/HEATERS
Unit Type : OCS (Other combustion source)
Unit Description :
Other Unit Name :
Small Unit Aggregation Details:
Use Ivt Indicator: N
Highest Maximum Rated Heat Input Capacity: 49.2
Cumulative Maximum Rated Heat Input Capacity: 156.02

Emission Details:
Annual CO2 mass emissions from sorbent: 0 (Metric Tons)
Annual Biogenic CO2 Emissions: 0 (metric tons)
Annual Fossil fuel based CO2 Emissions: 43380.90092 (metric tons)

Tier Fuel Details:
Fuel : Natural Gas (Weighted U.S. Average)
Tier Name : Tier 2 (Equation C-2a)
Tier Methodology Start Date : 2020-01-01
Tier Methodology End Date : 2020-12-31
Frequency of HHV determinations : Monthly

Tier 2 Monthly HHV Details :
JanuaryFebruaryMarchAprilMayJuneJulyAugustSeptemberOctoberNovemberDecember
N N N N N N N N N N N N

Fuel Emission Details :
Total CO2 emissionsTotal CH4 emissionsTotal N2O emissionsTotal CH4 emissions CO2eTotal N2O emissions CO2e
43380.90092 (Metric Tons) 0.817582 (Metric Tons) 0.0817582 (Metric Tons) 20.43955 (Metric Tons) 24.3639436 (Metric Tons)

Equation C2a/C9a Inputs :
Fuel Quantity : 842000000 ()
Use Default High Heat Value : false
Equation C2b Inputs :
Fuel CombustedHigh Heat Value
January70166666.6666667 ()0.000971 ()
February70166666.6666667 ()0.000971 ()
March70166666.6666667 ()0.000971 ()
April70166666.6666667 ()0.000971 ()
May70166666.6666667 ()0.000971 ()
June70166666.6666667 ()0.000971 ()
July70166666.6666667 ()0.000971 ()
August70166666.6666667 ()0.000971 ()
September70166666.6666667 ()0.000971 ()
October70166666.6666667 ()0.000971 ()
November70166666.6666667 ()0.000971 ()
December70166666.6666667 ()0.000971 ()


Subpart W: Petroleum and Natural Gas Systems

Gas Information Details

Gas NameCarbon Dioxide
Gas Quantity164,243.120481 (Metric Tons)
Own Result?

Gas NameMethane
Gas Quantity1,004.908785 (Metric Tons)
Own Result?

Gas NameNitrous Oxide
Gas Quantity0.147545 (Metric Tons)
Own Result?


SubpartWSummaryDetails:
Industry Segment Number3
Industry Segment NameOnshore natural gas processing [98.230(a)(3)]
Total Reported CO2 Emissions (mt CO2)164243.120481108
Total CO2e Emissions (mt CO2e)189409.808579244
Total Reported CH4 Emissions (mt CH4)1004.90878495374
Total Reported N2O Emissions (mt N2O)0.147545215748946


SubpartWSourceReportingFormRowDetails:
Source Reporting FormOnshore Production [98.236(aa)(1)]
Required for Selected Industry SegmentNo
Source Reporting FormFacility Overview [98.236(aa)(2-11)]
Required for Selected Industry SegmentYes
Source Reporting FormNatural Gas Pneumatic Devices [98.236(b)]
Required for Selected Industry SegmentNo
Total Reported CO2 Emissions (mt CO2)0
Total Reported CH4 Emissions (mt CH4)0
Source Reporting FormNatural Gas Driven Pneumatic Pumps [98.236(c)]
Required for Selected Industry SegmentNo
Total Reported CO2 Emissions (mt CO2)0
Total Reported CH4 Emissions (mt CH4)0
Source Reporting FormAcid Gas Removal Units [98.236(d)]
Required for Selected Industry SegmentYes
Total Reported CO2 Emissions (mt CO2)72491.1849222421
Source Reporting FormDehydrators [98.236(e)]
Required for Selected Industry SegmentYes
Total Reported CO2 Emissions (mt CO2)501.461002782072
Total Reported CH4 Emissions (mt CH4)0.157744571904
Total Reported N2O Emissions (mt N2O)0.00001
Source Reporting FormWell Venting for Liquids Unloading [98.236(f)]
Required for Selected Industry SegmentNo
Total Reported CO2 Emissions (mt CO2)0
Total Reported CH4 Emissions (mt CH4)0
Source Reporting FormCompletions and Workovers with Hydraulic Fracturing [98.236(g)]
Required for Selected Industry SegmentNo
Total Reported CO2 Emissions (mt CO2)0
Total Reported CH4 Emissions (mt CH4)0
Total Reported N2O Emissions (mt N2O)0
Source Reporting FormCompletions and Workovers without Hydraulic Fracturing [98.236(h)]
Required for Selected Industry SegmentNo
Total Reported CO2 Emissions (mt CO2)0
Total Reported CH4 Emissions (mt CH4)0
Total Reported N2O Emissions (mt N2O)0
Source Reporting FormBlowdown Vent Stacks [98.236(i)]
Required for Selected Industry SegmentYes
Total Reported CO2 Emissions (mt CO2)0
Total Reported CH4 Emissions (mt CH4)0
Source Reporting FormAtmospheric Storage Tanks [98.236(j)]
Required for Selected Industry SegmentNo
Total Reported CO2 Emissions (mt CO2)0
Total Reported CH4 Emissions (mt CH4)0
Total Reported N2O Emissions (mt N2O)0
Source Reporting FormTransmission Storage Tanks [98.236(k)]
Required for Selected Industry SegmentNo
Total Reported CO2 Emissions (mt CO2)0
Total Reported CH4 Emissions (mt CH4)0
Total Reported N2O Emissions (mt N2O)0
Source Reporting FormWell Testing [98.236(l)]
Required for Selected Industry SegmentNo
Total Reported CO2 Emissions (mt CO2)0
Total Reported CH4 Emissions (mt CH4)0
Total Reported N2O Emissions (mt N2O)0
Source Reporting FormAssociated Gas Venting and Flaring [98.236(m)]
Required for Selected Industry SegmentNo
Total Reported CO2 Emissions (mt CO2)0
Total Reported CH4 Emissions (mt CH4)0
Total Reported N2O Emissions (mt N2O)0
Source Reporting FormFlare Stacks [98.236(n)]
Required for Selected Industry SegmentYes
Total Reported CO2 Emissions (mt CO2)91235.0308522093
Total Reported CH4 Emissions (mt CH4)418.954503859358
Total Reported N2O Emissions (mt N2O)0.147535172768466
Source Reporting FormCentrifugal Compressors [98.236(o)]
Required for Selected Industry SegmentYes
Total Reported CO2 Emissions (mt CO2)0
Total Reported CH4 Emissions (mt CH4)0
Source Reporting FormReciprocating Compressors [98.236(p)]
Required for Selected Industry SegmentYes
Total Reported CO2 Emissions (mt CO2)9.92112937099152
Total Reported CH4 Emissions (mt CH4)434.088637509361
Source Reporting FormEquipment Leaks Surveys and Population Counts [98.236(q,r)]
Required for Selected Industry SegmentYes
Total Reported CO2 Emissions (mt CO2)5.5225745030304
Total Reported CH4 Emissions (mt CH4)151.70789901312
Source Reporting FormOffshore Petroleum and Natural Gas Production [98.236(s)]
Required for Selected Industry SegmentNo
Total Reported CO2 Emissions (mt CO2)0
Total Reported CH4 Emissions (mt CH4)0
Total Reported N2O Emissions (mt N2O)0
Source Reporting FormEnhanced Oil Recovery Injection Pumps [98.236(w)]
Required for Selected Industry SegmentNo
Total Reported CO2 Emissions (mt CO2)0
Source Reporting FormEnhanced Oil Recovery Hydrocarbon Liquids [98.236(x)]
Required for Selected Industry SegmentNo
Total Reported CO2 Emissions (mt CO2)0
Source Reporting FormCombustion Equipment at Onshore Petroleum and Natural Gas Production Facilities, Onshore Petroleum and Natural Gas Gathering and Boosting Facilities, and Natural gas Distribution Facilities [98.236(z)]
Required for Selected Industry SegmentNo
Total Reported CO2 Emissions (mt CO2)0
Total Reported CH4 Emissions (mt CH4)0
Total Reported N2O Emissions (mt N2O)0


FacilityOverviewDetails:


FacilityOverviewNaturalGasProcessingRowDetails:
Average mole fraction of CH4 in natural gas received [98.236(aa)(3)(v)]0.73
Average mole fraction of CO2 in natural gas received [98.236(aa)(3)(vi)]0.0097
Does the facility fractionate NGLs? [98.236(aa)(3)(vii)]No


AcidGasRemovalUnitsDetails:
mt CO272491.1849222421
Did the Facility have any acid gas removal units that vent directly to the atmosphere, to a flare or engine, or to a sulfur recovery plant subject to reporting under 98.232 [98.236(d)]?Yes
Were missing data procedures used for any parameters to calculate GHG emissions? [98.235]No


AcidGasInfoRowDetails:
Unit ID or Name [98.236(d)(1)(i)]AMN_EDWARDS AGR 001
Total feed rate entering the acid gas removal unit for the year (million cubic feet) [98.236(d)(1)(ii)]95606
Calculation Method Used (Select from list) [98.236(d)(1)(iii)]Calculation Methodology 2 [98.233(d)(2)]
Are any CO2 emissions from the acid gas removal unit recovered and transferred outside the facility? (Yes / No) [98.236(d)(1)(iv)]No
Total CO2 Emissions (mt CO2) [98.236(d)(1)(v)]54910.0241622421
Unit ID or Name [98.236(d)(1)(i)]AMN_Joyce Amine System
Total feed rate entering the acid gas removal unit for the year (million cubic feet) [98.236(d)(1)(ii)]34458
Calculation Method Used (Select from list) [98.236(d)(1)(iii)]Calculation Methodology 3 [98.233(d)(3)]
Are any CO2 emissions from the acid gas removal unit recovered and transferred outside the facility? (Yes / No) [98.236(d)(1)(iv)]No
Total CO2 Emissions (mt CO2) [98.236(d)(1)(v)]17581.16076


AcidGasCalcMethod2EmissionsRowDetails:
Unit ID or Name [98.236(d)(1)(i)]AMN_EDWARDS AGR 001
Annual average fraction of CO2 content in the vent from the acid gas removal unit, VolCO2 (volumetric fraction) [98.236(d)(2)(i)(A)]0.9653
Annual volume of gas vented from the acid gas removal unit, Vs (actual or standard cubic feet) [98.236(d)(2)(i)(B)]1081442877
Annual volume of gas vented reported on an Actual or Standard basis? [98.236]Standard
Temperature used to calculate volume of gas vented (°F) [98.236]60
Pressure used to calculate volume of gas vented (psi) [98.236]14.7


AcidGasCalcMethod3EmissionsRowDetails:
Unit ID or Name [98.236(d)(1)(i)]AMN_Joyce Amine System
Equation Used (W-4A/W-4B) [98.236(d)(2)(ii)(A)]W-4A
Annual average fraction of CO2 content of natural gas into the acid gas removal unit, Voli (volumetric fraction) [98.236(d)(2)(ii)(C)]0.0097
Annual average fraction of CO2 content of natural gas out of the acid gas removal unit, Volo (volumetric fraction) [98.236(d)(2)(ii)(B)]0
Natural gas flow rate into the acid gas removal unit, Vin (actual or standard cubic feet) (Eq. W-4A) [98.236(d)(2)(ii)(D)]34458000000
Natural gas flow rate reported on an Actual or Standard basis? [98.236]Standard
Temperature used to calculate natural gas flow rate (°F) [98.236]60
Pressure used to calculate natural gas flow rate (psi) [98.236]14.7


DehydratorsDetails:
mt CO2501.461002782072
mt CH40.157744571904
mt N2O0.00001
Did the facility have any glycol dehydrators with annual average daily natural gas throughputs greater than or equal to 0.4MMscfd subject to reporting under 98.232 [98.236(e)]?Yes
Did the facility have any glycol dehydrators with annual average daily natural gas throughputs less than 0.4MMscfd subject to reporting under 98.232 [98.236(e)]?No
Did the facility have any desiccant dehydrators subject to reporting under 98.232 [98.236(e)]?Yes
Were missing data procedures used for any parameters to calculate GHG emissions? [98.235]No


SmallGlycolDehydrators:
Emissions vented to flare or regenerator firebox/fire tubes
Emissions that were not vented to a flare or regenerator firebox/fire tubes


DessicantDehydrators:
Total Number of Desiccant Dehydrators [98.236(e)(3)(i)]6
Vapor RecoveryNo
Dehydrator vents to flares or regenerator firebox/fire tubesYes
Number of Desiccant Dehydrators By Vent Control Type, Count [98.236(e)(3)(i)]3
Control devices other than vapor recovery, flare or regenerator firebox/fire tubesNo
Emissions vented to flare or regenerator firebox/fire tubes
Total CO2 Emissions (mt CO2) [98.236(e)(3)(i)] [98.236(e)(3)(ii)]0.00251297676
Total CH4 Emissions (mt CH4) [98.236(e)(3)(i)] [98.236(e)(3)(iii)]0.00005
Total N2O Emissions (mt N2O) [98.236(e)(3)(i)]0
Emissions that were not vented to a flare or regenerator firebox/fire tubes
Total CO2 Emissions (mt CO2) [98.236(e)(3)(i)] [98.236(e)(3)(ii)]0
Total CH4 Emissions (mt CH4) [98.236(e)(3)(i)] [98.236(e)(3)(iii)]0


GlycolDehydratorsMoreThanSpecifiedValueRowDetails:
Unit ID or Name [98.236(e)(1)(i)]DEHY_Joyce TEG Dehydration System
Glycol dehydrator feed natural gas flow rate determined by engineering estimate based on best available data (MMscfd) [98.236(e)(1)(ii)]95.19
Dehydrator feed natural gas water content (pounds per MMscf) [98.236(e)(1)(iii)]110.85
Dehydrator outlet natural gas water content (pounds per MMscf) [98.236(e)(1)(iv)]7
Glycol dehydrator absorbent circulation pump type [98.236(e)(1)(v)]Electric
Dehydrator absorbent circulation rate (gallons per minute) [98.236(e)(1)(vi)]25
Report type of absorbent used [98.236(e)(1)(vii)]Triethylene glycol (TEG)
Report whether stripper gas is used in glycol dehydrator [98.236(e)(1)(viii)]No
Report whether a flash tank separator is used in glycol dehydrator [98.236(e)(1)(ix)]Yes
Total time the glycol dehydrator is operating (hours) [98.236(e)(1)(x)]8688
Temperature of the wet natural gas (°F) [98.236(e)(1)(xi)]120
Pressure of the wet natural gas (psig) [98.236(e)(1)(xii)]60
Concentration of CO2 in wet natural gas (mole fraction) [98.236(e)(1)(xiv)]0.0097
Concentration of CH4 in wet natural gas (mole fraction) [98.236(e)(1)(xiii)]0.73
Were any dehydrator emissions vented to a vapor recovery device? [98.236(e)(1)(xv)]No
Were any dehydrator emissions vented to a flare or regenerator firebox/fire tubes? [98.236(e)(1)(xvi)]Yes
CO2 Emissions from Flares or Regenerators (mt CO2) [98.236(e)(1)(xvi)(A)]501.458489805312
CH4 Emissions from Flares or Regenerators (mt CH4) [98.236(e)(1)(xvi)(B)]0.157695123456
N2O Emissions from Flares or Regenerators (mt N2O) [98.236(e)(1)(xvi)(C)]0.00001
Were any dehydrator emissions vented to the atmosphere without being routed to a flare or regenerator firebox/fire tubes? [98.236(e)(1)(xvii)]No


BlowdownVentStacksDetails:
mt CO20
mt CH40
Did the facility have any blowdown vent stacks subject to reporting under 98.232 [98.236(i)]?No


FlareStacksDetails:
mt CO291235.0308522093
mt CH4418.954503859358
mt N2O0.147535172768466
Did the facility have flare stacks subject to reporting under 98.232 [98.236(n)]?Yes
Were missing data procedures used for any parameters to calculate GHG emissions? [98.235]No


UniqueFlareStacksRowDetails:
Unique Name or ID Number for the Flare Stack [98.236(n)(1)]FLARE_BNP Flare (Benedum Inlet)
Does the flare stack have a continuous flow monitor on gas to the flare? [98.236(n)(2)]Yes
Does the flare stack have a continuous gas analyzer on gas to the flare? [98.236(n)(3)]No
Were CEMS used to measure CO2 emissions for the flare stack? [98.233(n)(8)] [98.236(n)(12)]No
Volume of gas sent to flare, Vs (standard cubic feet) [98.236(n)(4)]15370000
Flare combustion efficiency (decimal value) [98.236(n)(6)]0.98
Mole fraction of CH4 in flare feed gas, XCH4 [98.236(n)(7)]0.73
Mole fraction of CO2 in flare feed gas, XCO2 [98.236(n)(8)]0.0097
Fraction of feed gas sent to un-lit flare, Zu [98.236(n)(5)]0
CO2 emissions (mt CO2) [98.236(n)(9)]1041.071069716
CH4 Emissions (mt CH4) (Eq. W-19) [98.236(n)(10)]4.3085184
N2O Emissions (mt N2O) (Eq. W-40) [98.236(n)(11)]0.0019506067
Unique Name or ID Number for the Flare Stack [98.236(n)(1)]FLARE_Edward Flare (Edward Inlet)
Does the flare stack have a continuous flow monitor on gas to the flare? [98.236(n)(2)]Yes
Does the flare stack have a continuous gas analyzer on gas to the flare? [98.236(n)(3)]No
Were CEMS used to measure CO2 emissions for the flare stack? [98.233(n)(8)] [98.236(n)(12)]No
Volume of gas sent to flare, Vs (standard cubic feet) [98.236(n)(4)]385637000
Flare combustion efficiency (decimal value) [98.236(n)(6)]0.98
Mole fraction of CH4 in flare feed gas, XCH4 [98.236(n)(7)]0.73
Mole fraction of CO2 in flare feed gas, XCO2 [98.236(n)(8)]0.0097
Fraction of feed gas sent to un-lit flare, Zu [98.236(n)(5)]0
CO2 emissions (mt CO2) [98.236(n)(9)]26120.7237548516
CH4 Emissions (mt CH4) (Eq. W-19) [98.236(n)(10)]108.10176384
N2O Emissions (mt N2O) (Eq. W-40) [98.236(n)(11)]0.048827814392
Unique Name or ID Number for the Flare Stack [98.236(n)(1)]FLARE_Edward Flare (Edward Residue)
Does the flare stack have a continuous flow monitor on gas to the flare? [98.236(n)(2)]Yes
Does the flare stack have a continuous gas analyzer on gas to the flare? [98.236(n)(3)]No
Were CEMS used to measure CO2 emissions for the flare stack? [98.233(n)(8)] [98.236(n)(12)]No
Volume of gas sent to flare, Vs (standard cubic feet) [98.236(n)(4)]621860744
Flare combustion efficiency (decimal value) [98.236(n)(6)]0.98
Mole fraction of CH4 in flare feed gas, XCH4 [98.236(n)(7)]0.9417
Mole fraction of CO2 in flare feed gas, XCO2 [98.236(n)(8)]0.0002
Fraction of feed gas sent to un-lit flare, Zu [98.236(n)(5)]0
CO2 emissions (mt CO2) [98.236(n)(9)]32061.664265996
CH4 Emissions (mt CH4) (Eq. W-19) [98.236(n)(10)]224.872804847923
N2O Emissions (mt N2O) (Eq. W-40) [98.236(n)(11)]0.059175024677552
Unique Name or ID Number for the Flare Stack [98.236(n)(1)]FLARE_Edward Thermal Oxidizer (Edward Acid)
Does the flare stack have a continuous flow monitor on gas to the flare? [98.236(n)(2)]Yes
Does the flare stack have a continuous gas analyzer on gas to the flare? [98.236(n)(3)]No
Were CEMS used to measure CO2 emissions for the flare stack? [98.233(n)(8)] [98.236(n)(12)]No
Volume of gas sent to flare, Vs (standard cubic feet) [98.236(n)(4)]1197175000
Flare combustion efficiency (decimal value) [98.236(n)(6)]0.995
Mole fraction of CH4 in flare feed gas, XCH4 [98.236(n)(7)]0.0222
Mole fraction of CO2 in flare feed gas, XCO2 [98.236(n)(8)]0.9653
Fraction of feed gas sent to un-lit flare, Zu [98.236(n)(5)]0
CO2 emissions (mt CO2) [98.236(n)(9)]16791.2712294696
CH4 Emissions (mt CH4) (Eq. W-19) [98.236(n)(10)]2.79506734998251
N2O Emissions (mt N2O) (Eq. W-40) [98.236(n)(11)]0.00810008605
Unique Name or ID Number for the Flare Stack [98.236(n)(1)]FLARE_Joyce FL-801 (Inlet)
Does the flare stack have a continuous flow monitor on gas to the flare? [98.236(n)(2)]Yes
Does the flare stack have a continuous gas analyzer on gas to the flare? [98.236(n)(3)]No
Were CEMS used to measure CO2 emissions for the flare stack? [98.233(n)(8)] [98.236(n)(12)]No
Volume of gas sent to flare, Vs (standard cubic feet) [98.236(n)(4)]131945000
Flare combustion efficiency (decimal value) [98.236(n)(6)]0.98
Mole fraction of CH4 in flare feed gas, XCH4 [98.236(n)(7)]0.73
Mole fraction of CO2 in flare feed gas, XCO2 [98.236(n)(8)]0.0097
Fraction of feed gas sent to un-lit flare, Zu [98.236(n)(5)]0
CO2 emissions (mt CO2) [98.236(n)(9)]8937.158249426
CH4 Emissions (mt CH4) (Eq. W-19) [98.236(n)(10)]36.9868224
N2O Emissions (mt N2O) (Eq. W-40) [98.236(n)(11)]0.01674513995
Unique Name or ID Number for the Flare Stack [98.236(n)(1)]FLARE_Joyce FL-801 (Residue)
Does the flare stack have a continuous flow monitor on gas to the flare? [98.236(n)(2)]Yes
Does the flare stack have a continuous gas analyzer on gas to the flare? [98.236(n)(3)]No
Were CEMS used to measure CO2 emissions for the flare stack? [98.233(n)(8)] [98.236(n)(12)]No
Volume of gas sent to flare, Vs (standard cubic feet) [98.236(n)(4)]110655479
Flare combustion efficiency (decimal value) [98.236(n)(6)]0.98
Mole fraction of CH4 in flare feed gas, XCH4 [98.236(n)(7)]0.9523
Mole fraction of CO2 in flare feed gas, XCO2 [98.236(n)(8)]0
Fraction of feed gas sent to un-lit flare, Zu [98.236(n)(5)]0
CO2 emissions (mt CO2) [98.236(n)(9)]5666.9921853873
CH4 Emissions (mt CH4) (Eq. W-19) [98.236(n)(10)]40.4648496582528
N2O Emissions (mt N2O) (Eq. W-40) [98.236(n)(11)]0.010486377122914
Unique Name or ID Number for the Flare Stack [98.236(n)(1)]FLARE_Joyce VC-501 (Joyce Acid Gas)
Does the flare stack have a continuous flow monitor on gas to the flare? [98.236(n)(2)]Yes
Does the flare stack have a continuous gas analyzer on gas to the flare? [98.236(n)(3)]No
Were CEMS used to measure CO2 emissions for the flare stack? [98.233(n)(8)] [98.236(n)(12)]No
Volume of gas sent to flare, Vs (standard cubic feet) [98.236(n)(4)]334243000
Flare combustion efficiency (decimal value) [98.236(n)(6)]0.99
Mole fraction of CH4 in flare feed gas, XCH4 [98.236(n)(7)]0.0222
Mole fraction of CO2 in flare feed gas, XCO2 [98.236(n)(8)]0.9653
Fraction of feed gas sent to un-lit flare, Zu [98.236(n)(5)]0
CO2 emissions (mt CO2) [98.236(n)(9)]616.150097362803
CH4 Emissions (mt CH4) (Eq. W-19) [98.236(n)(10)]1.4246773632
N2O Emissions (mt N2O) (Eq. W-40) [98.236(n)(11)]0.002250123876


CentrifugalCompressorsDetails:
mt CO20
mt CH40
Did the facility have any centrifugal compressors subject to reporting under 98.232 [98.236(o)]?No


ReciprocatingCompressorsDetails:
mt CO29.92112937099152
mt CH4434.088637509361
Did the facility have any reciprocating compressors subject to reporting under 98.232 [98.236(p)]?Yes
Were missing data procedures used for any parameters to calculate GHG emissions? [98.235]No


ReciprocatingCompressorsActivityDataRowDetails:
Unique name or ID for reciprocating compressor [98.236(p)(1)(i)]RECIP_Benedum B-1R
Total time in operating-mode (hours) [98.236(p)(1)(ii)]0
Total time in standby-pressurized-mode (hours) [98.236(p)(1)(iii)]0
Total time in not-operating-depressurized-mode (hours) [98.236(p)(1)(iv)]0
Compressor measured in operating-mode? [98.236(p)(1)(v)]No
Compressor measured in standby-pressurized-mode? [98.236(p)(1)(vi)]No
Compressor measured in not-operating-depressurized-mode? [98.236(p)(1)(vii)]No
Compressor had blind flanges installed? [98.236(p)(1)(xii)]Yes
Dates for blind flange installation (mm/dd/yyyy - mm/dd/yyyy) [98.236(p)(1)(xii)]2018-01-01
Power output of compressor driver (hp) [98.236(p)(1)(xiii)]1232
Compressor had scheduled depressurized shutdown during reporting year? [98.236(p)(1)(xiv)]Yes
Unique name or ID for reciprocating compressor [98.236(p)(1)(i)]RECIP_Benedum B-2
Total time in operating-mode (hours) [98.236(p)(1)(ii)]0
Total time in standby-pressurized-mode (hours) [98.236(p)(1)(iii)]0
Total time in not-operating-depressurized-mode (hours) [98.236(p)(1)(iv)]0
Compressor measured in operating-mode? [98.236(p)(1)(v)]No
Compressor measured in standby-pressurized-mode? [98.236(p)(1)(vi)]No
Compressor measured in not-operating-depressurized-mode? [98.236(p)(1)(vii)]No
Compressor had blind flanges installed? [98.236(p)(1)(xii)]Yes
Dates for blind flange installation (mm/dd/yyyy - mm/dd/yyyy) [98.236(p)(1)(xii)]2018-01-01
Power output of compressor driver (hp) [98.236(p)(1)(xiii)]2090
Compressor had scheduled depressurized shutdown during reporting year? [98.236(p)(1)(xiv)]Yes
Unique name or ID for reciprocating compressor [98.236(p)(1)(i)]RECIP_Benedum B-3
Total time in operating-mode (hours) [98.236(p)(1)(ii)]0
Total time in standby-pressurized-mode (hours) [98.236(p)(1)(iii)]0
Total time in not-operating-depressurized-mode (hours) [98.236(p)(1)(iv)]0
Compressor measured in operating-mode? [98.236(p)(1)(v)]No
Compressor measured in standby-pressurized-mode? [98.236(p)(1)(vi)]No
Compressor measured in not-operating-depressurized-mode? [98.236(p)(1)(vii)]No
Compressor had blind flanges installed? [98.236(p)(1)(xii)]Yes
Dates for blind flange installation (mm/dd/yyyy - mm/dd/yyyy) [98.236(p)(1)(xii)]2018-01-01
Power output of compressor driver (hp) [98.236(p)(1)(xiii)]2090
Compressor had scheduled depressurized shutdown during reporting year? [98.236(p)(1)(xiv)]Yes
Unique name or ID for reciprocating compressor [98.236(p)(1)(i)]RECIP_Benedum B-4
Total time in operating-mode (hours) [98.236(p)(1)(ii)]0
Total time in standby-pressurized-mode (hours) [98.236(p)(1)(iii)]0
Total time in not-operating-depressurized-mode (hours) [98.236(p)(1)(iv)]0
Compressor measured in operating-mode? [98.236(p)(1)(v)]No
Compressor measured in standby-pressurized-mode? [98.236(p)(1)(vi)]No
Compressor measured in not-operating-depressurized-mode? [98.236(p)(1)(vii)]No
Compressor had blind flanges installed? [98.236(p)(1)(xii)]Yes
Dates for blind flange installation (mm/dd/yyyy - mm/dd/yyyy) [98.236(p)(1)(xii)]2018-01-01
Power output of compressor driver (hp) [98.236(p)(1)(xiii)]1665
Compressor had scheduled depressurized shutdown during reporting year? [98.236(p)(1)(xiv)]Yes
Unique name or ID for reciprocating compressor [98.236(p)(1)(i)]RECIP_Benedum B-5
Total time in operating-mode (hours) [98.236(p)(1)(ii)]0
Total time in standby-pressurized-mode (hours) [98.236(p)(1)(iii)]0
Total time in not-operating-depressurized-mode (hours) [98.236(p)(1)(iv)]0
Compressor measured in operating-mode? [98.236(p)(1)(v)]No
Compressor measured in standby-pressurized-mode? [98.236(p)(1)(vi)]No
Compressor measured in not-operating-depressurized-mode? [98.236(p)(1)(vii)]No
Compressor had blind flanges installed? [98.236(p)(1)(xii)]Yes
Dates for blind flange installation (mm/dd/yyyy - mm/dd/yyyy) [98.236(p)(1)(xii)]2018-01-01
Power output of compressor driver (hp) [98.236(p)(1)(xiii)]1665
Compressor had scheduled depressurized shutdown during reporting year? [98.236(p)(1)(xiv)]Yes
Unique name or ID for reciprocating compressor [98.236(p)(1)(i)]RECIP_Edward C-101
Total time in operating-mode (hours) [98.236(p)(1)(ii)]8004
Total time in standby-pressurized-mode (hours) [98.236(p)(1)(iii)]0
Total time in not-operating-depressurized-mode (hours) [98.236(p)(1)(iv)]780
Compressor measured in operating-mode? [98.236(p)(1)(v)]Yes
Compressor measured in standby-pressurized-mode? [98.236(p)(1)(vi)]No
Compressor measured in not-operating-depressurized-mode? [98.236(p)(1)(vii)]No
Compressor had blind flanges installed? [98.236(p)(1)(xii)]No
Power output of compressor driver (hp) [98.236(p)(1)(xiii)]3500
Compressor had scheduled depressurized shutdown during reporting year? [98.236(p)(1)(xiv)]No
Unique name or ID for reciprocating compressor [98.236(p)(1)(i)]RECIP_Edward C-102
Total time in operating-mode (hours) [98.236(p)(1)(ii)]7587
Total time in standby-pressurized-mode (hours) [98.236(p)(1)(iii)]0
Total time in not-operating-depressurized-mode (hours) [98.236(p)(1)(iv)]1197
Compressor measured in operating-mode? [98.236(p)(1)(v)]Yes
Compressor measured in standby-pressurized-mode? [98.236(p)(1)(vi)]No
Compressor measured in not-operating-depressurized-mode? [98.236(p)(1)(vii)]No
Compressor had blind flanges installed? [98.236(p)(1)(xii)]No
Power output of compressor driver (hp) [98.236(p)(1)(xiii)]3500
Compressor had scheduled depressurized shutdown during reporting year? [98.236(p)(1)(xiv)]No
Unique name or ID for reciprocating compressor [98.236(p)(1)(i)]RECIP_Edward C-201
Total time in operating-mode (hours) [98.236(p)(1)(ii)]8274
Total time in standby-pressurized-mode (hours) [98.236(p)(1)(iii)]0
Total time in not-operating-depressurized-mode (hours) [98.236(p)(1)(iv)]510
Compressor measured in operating-mode? [98.236(p)(1)(v)]Yes
Compressor measured in standby-pressurized-mode? [98.236(p)(1)(vi)]No
Compressor measured in not-operating-depressurized-mode? [98.236(p)(1)(vii)]No
Compressor had blind flanges installed? [98.236(p)(1)(xii)]No
Power output of compressor driver (hp) [98.236(p)(1)(xiii)]3500
Compressor had scheduled depressurized shutdown during reporting year? [98.236(p)(1)(xiv)]No
Unique name or ID for reciprocating compressor [98.236(p)(1)(i)]RECIP_Edward C-202
Total time in operating-mode (hours) [98.236(p)(1)(ii)]8358
Total time in standby-pressurized-mode (hours) [98.236(p)(1)(iii)]0
Total time in not-operating-depressurized-mode (hours) [98.236(p)(1)(iv)]426
Compressor measured in operating-mode? [98.236(p)(1)(v)]Yes
Compressor measured in standby-pressurized-mode? [98.236(p)(1)(vi)]No
Compressor measured in not-operating-depressurized-mode? [98.236(p)(1)(vii)]No
Compressor had blind flanges installed? [98.236(p)(1)(xii)]No
Power output of compressor driver (hp) [98.236(p)(1)(xiii)]3500
Compressor had scheduled depressurized shutdown during reporting year? [98.236(p)(1)(xiv)]No
Unique name or ID for reciprocating compressor [98.236(p)(1)(i)]RECIP_Edward C-203
Total time in operating-mode (hours) [98.236(p)(1)(ii)]8402
Total time in standby-pressurized-mode (hours) [98.236(p)(1)(iii)]0
Total time in not-operating-depressurized-mode (hours) [98.236(p)(1)(iv)]382
Compressor measured in operating-mode? [98.236(p)(1)(v)]Yes
Compressor measured in standby-pressurized-mode? [98.236(p)(1)(vi)]No
Compressor measured in not-operating-depressurized-mode? [98.236(p)(1)(vii)]No
Compressor had blind flanges installed? [98.236(p)(1)(xii)]No
Power output of compressor driver (hp) [98.236(p)(1)(xiii)]3500
Compressor had scheduled depressurized shutdown during reporting year? [98.236(p)(1)(xiv)]No
Unique name or ID for reciprocating compressor [98.236(p)(1)(i)]RECIP_Edward C-204
Total time in operating-mode (hours) [98.236(p)(1)(ii)]8197
Total time in standby-pressurized-mode (hours) [98.236(p)(1)(iii)]0
Total time in not-operating-depressurized-mode (hours) [98.236(p)(1)(iv)]587
Compressor measured in operating-mode? [98.236(p)(1)(v)]Yes
Compressor measured in standby-pressurized-mode? [98.236(p)(1)(vi)]No
Compressor measured in not-operating-depressurized-mode? [98.236(p)(1)(vii)]No
Compressor had blind flanges installed? [98.236(p)(1)(xii)]No
Power output of compressor driver (hp) [98.236(p)(1)(xiii)]3500
Compressor had scheduled depressurized shutdown during reporting year? [98.236(p)(1)(xiv)]No
Unique name or ID for reciprocating compressor [98.236(p)(1)(i)]RECIP_Edward C-205
Total time in operating-mode (hours) [98.236(p)(1)(ii)]8340
Total time in standby-pressurized-mode (hours) [98.236(p)(1)(iii)]0
Total time in not-operating-depressurized-mode (hours) [98.236(p)(1)(iv)]444
Compressor measured in operating-mode? [98.236(p)(1)(v)]Yes
Compressor measured in standby-pressurized-mode? [98.236(p)(1)(vi)]No
Compressor measured in not-operating-depressurized-mode? [98.236(p)(1)(vii)]No
Compressor had blind flanges installed? [98.236(p)(1)(xii)]No
Power output of compressor driver (hp) [98.236(p)(1)(xiii)]3500
Compressor had scheduled depressurized shutdown during reporting year? [98.236(p)(1)(xiv)]No
Unique name or ID for reciprocating compressor [98.236(p)(1)(i)]RECIP_Edward C-206
Total time in operating-mode (hours) [98.236(p)(1)(ii)]8329
Total time in standby-pressurized-mode (hours) [98.236(p)(1)(iii)]0
Total time in not-operating-depressurized-mode (hours) [98.236(p)(1)(iv)]455
Compressor measured in operating-mode? [98.236(p)(1)(v)]Yes
Compressor measured in standby-pressurized-mode? [98.236(p)(1)(vi)]No
Compressor measured in not-operating-depressurized-mode? [98.236(p)(1)(vii)]No
Compressor had blind flanges installed? [98.236(p)(1)(xii)]No
Power output of compressor driver (hp) [98.236(p)(1)(xiii)]3500
Compressor had scheduled depressurized shutdown during reporting year? [98.236(p)(1)(xiv)]No
Unique name or ID for reciprocating compressor [98.236(p)(1)(i)]RECIP_Edward C-207
Total time in operating-mode (hours) [98.236(p)(1)(ii)]7993
Total time in standby-pressurized-mode (hours) [98.236(p)(1)(iii)]0
Total time in not-operating-depressurized-mode (hours) [98.236(p)(1)(iv)]791
Compressor measured in operating-mode? [98.236(p)(1)(v)]Yes
Compressor measured in standby-pressurized-mode? [98.236(p)(1)(vi)]No
Compressor measured in not-operating-depressurized-mode? [98.236(p)(1)(vii)]No
Compressor had blind flanges installed? [98.236(p)(1)(xii)]No
Power output of compressor driver (hp) [98.236(p)(1)(xiii)]3500
Compressor had scheduled depressurized shutdown during reporting year? [98.236(p)(1)(xiv)]No
Unique name or ID for reciprocating compressor [98.236(p)(1)(i)]RECIP_Edward C-208
Total time in operating-mode (hours) [98.236(p)(1)(ii)]6884
Total time in standby-pressurized-mode (hours) [98.236(p)(1)(iii)]0
Total time in not-operating-depressurized-mode (hours) [98.236(p)(1)(iv)]1900
Compressor measured in operating-mode? [98.236(p)(1)(v)]Yes
Compressor measured in standby-pressurized-mode? [98.236(p)(1)(vi)]No
Compressor measured in not-operating-depressurized-mode? [98.236(p)(1)(vii)]No
Compressor had blind flanges installed? [98.236(p)(1)(xii)]No
Power output of compressor driver (hp) [98.236(p)(1)(xiii)]3500
Compressor had scheduled depressurized shutdown during reporting year? [98.236(p)(1)(xiv)]No
Unique name or ID for reciprocating compressor [98.236(p)(1)(i)]RECIP_Edward C-301
Total time in operating-mode (hours) [98.236(p)(1)(ii)]7472
Total time in standby-pressurized-mode (hours) [98.236(p)(1)(iii)]0
Total time in not-operating-depressurized-mode (hours) [98.236(p)(1)(iv)]1312
Compressor measured in operating-mode? [98.236(p)(1)(v)]Yes
Compressor measured in standby-pressurized-mode? [98.236(p)(1)(vi)]No
Compressor measured in not-operating-depressurized-mode? [98.236(p)(1)(vii)]No
Compressor had blind flanges installed? [98.236(p)(1)(xii)]No
Power output of compressor driver (hp) [98.236(p)(1)(xiii)]3500
Compressor had scheduled depressurized shutdown during reporting year? [98.236(p)(1)(xiv)]No
Unique name or ID for reciprocating compressor [98.236(p)(1)(i)]RECIP_Edward C-302
Total time in operating-mode (hours) [98.236(p)(1)(ii)]8112
Total time in standby-pressurized-mode (hours) [98.236(p)(1)(iii)]0
Total time in not-operating-depressurized-mode (hours) [98.236(p)(1)(iv)]672
Compressor measured in operating-mode? [98.236(p)(1)(v)]Yes
Compressor measured in standby-pressurized-mode? [98.236(p)(1)(vi)]No
Compressor measured in not-operating-depressurized-mode? [98.236(p)(1)(vii)]No
Compressor had blind flanges installed? [98.236(p)(1)(xii)]No
Power output of compressor driver (hp) [98.236(p)(1)(xiii)]3500
Compressor had scheduled depressurized shutdown during reporting year? [98.236(p)(1)(xiv)]No
Unique name or ID for reciprocating compressor [98.236(p)(1)(i)]RECIP_Edward C-303
Total time in operating-mode (hours) [98.236(p)(1)(ii)]8122
Total time in standby-pressurized-mode (hours) [98.236(p)(1)(iii)]0
Total time in not-operating-depressurized-mode (hours) [98.236(p)(1)(iv)]662
Compressor measured in operating-mode? [98.236(p)(1)(v)]Yes
Compressor measured in standby-pressurized-mode? [98.236(p)(1)(vi)]No
Compressor measured in not-operating-depressurized-mode? [98.236(p)(1)(vii)]No
Compressor had blind flanges installed? [98.236(p)(1)(xii)]No
Power output of compressor driver (hp) [98.236(p)(1)(xiii)]3500
Compressor had scheduled depressurized shutdown during reporting year? [98.236(p)(1)(xiv)]No
Unique name or ID for reciprocating compressor [98.236(p)(1)(i)]RECIP_Edward C-304
Total time in operating-mode (hours) [98.236(p)(1)(ii)]7900
Total time in standby-pressurized-mode (hours) [98.236(p)(1)(iii)]0
Total time in not-operating-depressurized-mode (hours) [98.236(p)(1)(iv)]884
Compressor measured in operating-mode? [98.236(p)(1)(v)]Yes
Compressor measured in standby-pressurized-mode? [98.236(p)(1)(vi)]No
Compressor measured in not-operating-depressurized-mode? [98.236(p)(1)(vii)]No
Compressor had blind flanges installed? [98.236(p)(1)(xii)]No
Power output of compressor driver (hp) [98.236(p)(1)(xiii)]3500
Compressor had scheduled depressurized shutdown during reporting year? [98.236(p)(1)(xiv)]No
Unique name or ID for reciprocating compressor [98.236(p)(1)(i)]RECIP_Edward C-305
Total time in operating-mode (hours) [98.236(p)(1)(ii)]8224
Total time in standby-pressurized-mode (hours) [98.236(p)(1)(iii)]0
Total time in not-operating-depressurized-mode (hours) [98.236(p)(1)(iv)]560
Compressor measured in operating-mode? [98.236(p)(1)(v)]Yes
Compressor measured in standby-pressurized-mode? [98.236(p)(1)(vi)]No
Compressor measured in not-operating-depressurized-mode? [98.236(p)(1)(vii)]No
Compressor had blind flanges installed? [98.236(p)(1)(xii)]No
Power output of compressor driver (hp) [98.236(p)(1)(xiii)]3500
Compressor had scheduled depressurized shutdown during reporting year? [98.236(p)(1)(xiv)]No
Unique name or ID for reciprocating compressor [98.236(p)(1)(i)]RECIP_Edward C-306
Total time in operating-mode (hours) [98.236(p)(1)(ii)]8046
Total time in standby-pressurized-mode (hours) [98.236(p)(1)(iii)]0
Total time in not-operating-depressurized-mode (hours) [98.236(p)(1)(iv)]738
Compressor measured in operating-mode? [98.236(p)(1)(v)]Yes
Compressor measured in standby-pressurized-mode? [98.236(p)(1)(vi)]No
Compressor measured in not-operating-depressurized-mode? [98.236(p)(1)(vii)]No
Compressor had blind flanges installed? [98.236(p)(1)(xii)]No
Power output of compressor driver (hp) [98.236(p)(1)(xiii)]3500
Compressor had scheduled depressurized shutdown during reporting year? [98.236(p)(1)(xiv)]No
Unique name or ID for reciprocating compressor [98.236(p)(1)(i)]RECIP_Edward C-307
Total time in operating-mode (hours) [98.236(p)(1)(ii)]6570
Total time in standby-pressurized-mode (hours) [98.236(p)(1)(iii)]0
Total time in not-operating-depressurized-mode (hours) [98.236(p)(1)(iv)]2214
Compressor measured in operating-mode? [98.236(p)(1)(v)]Yes
Compressor measured in standby-pressurized-mode? [98.236(p)(1)(vi)]No
Compressor measured in not-operating-depressurized-mode? [98.236(p)(1)(vii)]No
Compressor had blind flanges installed? [98.236(p)(1)(xii)]No
Power output of compressor driver (hp) [98.236(p)(1)(xiii)]3500
Compressor had scheduled depressurized shutdown during reporting year? [98.236(p)(1)(xiv)]No
Unique name or ID for reciprocating compressor [98.236(p)(1)(i)]RECIP_Joyce C-405
Total time in operating-mode (hours) [98.236(p)(1)(ii)]8163
Total time in standby-pressurized-mode (hours) [98.236(p)(1)(iii)]0
Total time in not-operating-depressurized-mode (hours) [98.236(p)(1)(iv)]621
Compressor measured in operating-mode? [98.236(p)(1)(v)]No
Compressor measured in standby-pressurized-mode? [98.236(p)(1)(vi)]No
Compressor measured in not-operating-depressurized-mode? [98.236(p)(1)(vii)]No
Compressor had blind flanges installed? [98.236(p)(1)(xii)]No
Power output of compressor driver (hp) [98.236(p)(1)(xiii)]3500
Compressor had scheduled depressurized shutdown during reporting year? [98.236(p)(1)(xiv)]Yes
Unique name or ID for reciprocating compressor [98.236(p)(1)(i)]RECIP_Joyce C-406
Total time in operating-mode (hours) [98.236(p)(1)(ii)]8011
Total time in standby-pressurized-mode (hours) [98.236(p)(1)(iii)]0
Total time in not-operating-depressurized-mode (hours) [98.236(p)(1)(iv)]773
Compressor measured in operating-mode? [98.236(p)(1)(v)]No
Compressor measured in standby-pressurized-mode? [98.236(p)(1)(vi)]No
Compressor measured in not-operating-depressurized-mode? [98.236(p)(1)(vii)]No
Compressor had blind flanges installed? [98.236(p)(1)(xii)]No
Power output of compressor driver (hp) [98.236(p)(1)(xiii)]3500
Compressor had scheduled depressurized shutdown during reporting year? [98.236(p)(1)(xiv)]Yes
Unique name or ID for reciprocating compressor [98.236(p)(1)(i)]RECIP_Joyce C-407
Total time in operating-mode (hours) [98.236(p)(1)(ii)]8247
Total time in standby-pressurized-mode (hours) [98.236(p)(1)(iii)]0
Total time in not-operating-depressurized-mode (hours) [98.236(p)(1)(iv)]537
Compressor measured in operating-mode? [98.236(p)(1)(v)]No
Compressor measured in standby-pressurized-mode? [98.236(p)(1)(vi)]No
Compressor measured in not-operating-depressurized-mode? [98.236(p)(1)(vii)]No
Compressor had blind flanges installed? [98.236(p)(1)(xii)]No
Power output of compressor driver (hp) [98.236(p)(1)(xiii)]3500
Compressor had scheduled depressurized shutdown during reporting year? [98.236(p)(1)(xiv)]Yes
Unique name or ID for reciprocating compressor [98.236(p)(1)(i)]RECIP_Joyce C-408
Total time in operating-mode (hours) [98.236(p)(1)(ii)]8184
Total time in standby-pressurized-mode (hours) [98.236(p)(1)(iii)]0
Total time in not-operating-depressurized-mode (hours) [98.236(p)(1)(iv)]600
Compressor measured in operating-mode? [98.236(p)(1)(v)]No
Compressor measured in standby-pressurized-mode? [98.236(p)(1)(vi)]No
Compressor measured in not-operating-depressurized-mode? [98.236(p)(1)(vii)]No
Compressor had blind flanges installed? [98.236(p)(1)(xii)]No
Power output of compressor driver (hp) [98.236(p)(1)(xiii)]3500
Compressor had scheduled depressurized shutdown during reporting year? [98.236(p)(1)(xiv)]Yes
Unique name or ID for reciprocating compressor [98.236(p)(1)(i)]RECIP_Joyce C-409
Total time in operating-mode (hours) [98.236(p)(1)(ii)]7747
Total time in standby-pressurized-mode (hours) [98.236(p)(1)(iii)]0
Total time in not-operating-depressurized-mode (hours) [98.236(p)(1)(iv)]1037
Compressor measured in operating-mode? [98.236(p)(1)(v)]No
Compressor measured in standby-pressurized-mode? [98.236(p)(1)(vi)]No
Compressor measured in not-operating-depressurized-mode? [98.236(p)(1)(vii)]No
Compressor had blind flanges installed? [98.236(p)(1)(xii)]No
Power output of compressor driver (hp) [98.236(p)(1)(xiii)]3500
Compressor had scheduled depressurized shutdown during reporting year? [98.236(p)(1)(xiv)]Yes
Unique name or ID for reciprocating compressor [98.236(p)(1)(i)]RECIP_Joyce C-410
Total time in operating-mode (hours) [98.236(p)(1)(ii)]8199
Total time in standby-pressurized-mode (hours) [98.236(p)(1)(iii)]0
Total time in not-operating-depressurized-mode (hours) [98.236(p)(1)(iv)]585
Compressor measured in operating-mode? [98.236(p)(1)(v)]No
Compressor measured in standby-pressurized-mode? [98.236(p)(1)(vi)]No
Compressor measured in not-operating-depressurized-mode? [98.236(p)(1)(vii)]No
Compressor had blind flanges installed? [98.236(p)(1)(xii)]No
Power output of compressor driver (hp) [98.236(p)(1)(xiii)]3500
Compressor had scheduled depressurized shutdown during reporting year? [98.236(p)(1)(xiv)]Yes
Unique name or ID for reciprocating compressor [98.236(p)(1)(i)]RECIP_Joyce C-411
Total time in operating-mode (hours) [98.236(p)(1)(ii)]8085
Total time in standby-pressurized-mode (hours) [98.236(p)(1)(iii)]0
Total time in not-operating-depressurized-mode (hours) [98.236(p)(1)(iv)]699
Compressor measured in operating-mode? [98.236(p)(1)(v)]No
Compressor measured in standby-pressurized-mode? [98.236(p)(1)(vi)]No
Compressor measured in not-operating-depressurized-mode? [98.236(p)(1)(vii)]No
Compressor had blind flanges installed? [98.236(p)(1)(xii)]No
Power output of compressor driver (hp) [98.236(p)(1)(xiii)]3500
Compressor had scheduled depressurized shutdown during reporting year? [98.236(p)(1)(xiv)]Yes
Unique name or ID for reciprocating compressor [98.236(p)(1)(i)]RECIP_Joyce C-701
Total time in operating-mode (hours) [98.236(p)(1)(ii)]7678
Total time in standby-pressurized-mode (hours) [98.236(p)(1)(iii)]0
Total time in not-operating-depressurized-mode (hours) [98.236(p)(1)(iv)]1106
Compressor measured in operating-mode? [98.236(p)(1)(v)]No
Compressor measured in standby-pressurized-mode? [98.236(p)(1)(vi)]No
Compressor measured in not-operating-depressurized-mode? [98.236(p)(1)(vii)]No
Compressor had blind flanges installed? [98.236(p)(1)(xii)]No
Power output of compressor driver (hp) [98.236(p)(1)(xiii)]3500
Compressor had scheduled depressurized shutdown during reporting year? [98.236(p)(1)(xiv)]Yes
Unique name or ID for reciprocating compressor [98.236(p)(1)(i)]RECIP_Joyce C-702
Total time in operating-mode (hours) [98.236(p)(1)(ii)]8042
Total time in standby-pressurized-mode (hours) [98.236(p)(1)(iii)]0
Total time in not-operating-depressurized-mode (hours) [98.236(p)(1)(iv)]742
Compressor measured in operating-mode? [98.236(p)(1)(v)]No
Compressor measured in standby-pressurized-mode? [98.236(p)(1)(vi)]No
Compressor measured in not-operating-depressurized-mode? [98.236(p)(1)(vii)]No
Compressor had blind flanges installed? [98.236(p)(1)(xii)]No
Power output of compressor driver (hp) [98.236(p)(1)(xiii)]3500
Compressor had scheduled depressurized shutdown during reporting year? [98.236(p)(1)(xiv)]Yes
Unique name or ID for reciprocating compressor [98.236(p)(1)(i)]RECIP_Joyce C-703
Total time in operating-mode (hours) [98.236(p)(1)(ii)]8271
Total time in standby-pressurized-mode (hours) [98.236(p)(1)(iii)]0
Total time in not-operating-depressurized-mode (hours) [98.236(p)(1)(iv)]513
Compressor measured in operating-mode? [98.236(p)(1)(v)]No
Compressor measured in standby-pressurized-mode? [98.236(p)(1)(vi)]No
Compressor measured in not-operating-depressurized-mode? [98.236(p)(1)(vii)]No
Compressor had blind flanges installed? [98.236(p)(1)(xii)]No
Power output of compressor driver (hp) [98.236(p)(1)(xiii)]3500
Compressor had scheduled depressurized shutdown during reporting year? [98.236(p)(1)(xiv)]Yes
Unique name or ID for reciprocating compressor [98.236(p)(1)(i)]RECIP_Joyce C-704
Total time in operating-mode (hours) [98.236(p)(1)(ii)]7916
Total time in standby-pressurized-mode (hours) [98.236(p)(1)(iii)]0
Total time in not-operating-depressurized-mode (hours) [98.236(p)(1)(iv)]868
Compressor measured in operating-mode? [98.236(p)(1)(v)]No
Compressor measured in standby-pressurized-mode? [98.236(p)(1)(vi)]No
Compressor measured in not-operating-depressurized-mode? [98.236(p)(1)(vii)]No
Compressor had blind flanges installed? [98.236(p)(1)(xii)]No
Power output of compressor driver (hp) [98.236(p)(1)(xiii)]3500
Compressor had scheduled depressurized shutdown during reporting year? [98.236(p)(1)(xiv)]Yes
Unique name or ID for reciprocating compressor [98.236(p)(1)(i)]RECIP_Joyce C-705
Total time in operating-mode (hours) [98.236(p)(1)(ii)]8340
Total time in standby-pressurized-mode (hours) [98.236(p)(1)(iii)]0
Total time in not-operating-depressurized-mode (hours) [98.236(p)(1)(iv)]444
Compressor measured in operating-mode? [98.236(p)(1)(v)]No
Compressor measured in standby-pressurized-mode? [98.236(p)(1)(vi)]No
Compressor measured in not-operating-depressurized-mode? [98.236(p)(1)(vii)]No
Compressor had blind flanges installed? [98.236(p)(1)(xii)]No
Power output of compressor driver (hp) [98.236(p)(1)(xiii)]3500
Compressor had scheduled depressurized shutdown during reporting year? [98.236(p)(1)(xiv)]Yes
Unique name or ID for reciprocating compressor [98.236(p)(1)(i)]RECIP_Joyce C-706
Total time in operating-mode (hours) [98.236(p)(1)(ii)]7869
Total time in standby-pressurized-mode (hours) [98.236(p)(1)(iii)]0
Total time in not-operating-depressurized-mode (hours) [98.236(p)(1)(iv)]915
Compressor measured in operating-mode? [98.236(p)(1)(v)]No
Compressor measured in standby-pressurized-mode? [98.236(p)(1)(vi)]No
Compressor measured in not-operating-depressurized-mode? [98.236(p)(1)(vii)]No
Compressor had blind flanges installed? [98.236(p)(1)(xii)]No
Power output of compressor driver (hp) [98.236(p)(1)(xiii)]3500
Compressor had scheduled depressurized shutdown during reporting year? [98.236(p)(1)(xiv)]Yes


ReciprocatingCompressorSourceRowDetails:
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]RECIP_Benedum B-1R
Reciprocating compressor source [98.236(p)(2)(i)(B)]Blowdown valve
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Benedum B-1R.Blowdown valve
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]RECIP_Benedum B-1R
Reciprocating compressor source [98.236(p)(2)(i)(B)]Isolation valve
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Benedum B-1R.Isolation valve
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]RECIP_Benedum B-1R
Reciprocating compressor source [98.236(p)(2)(i)(B)]Rod packing
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Benedum B-1R.Rod packing
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]RECIP_Benedum B-2
Reciprocating compressor source [98.236(p)(2)(i)(B)]Blowdown valve
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Benedum B-2.Blowdown valve
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]RECIP_Benedum B-2
Reciprocating compressor source [98.236(p)(2)(i)(B)]Isolation valve
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Benedum B-2.Isolation valve
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]RECIP_Benedum B-2
Reciprocating compressor source [98.236(p)(2)(i)(B)]Rod packing
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Benedum B-2.Rod packing
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]RECIP_Benedum B-3
Reciprocating compressor source [98.236(p)(2)(i)(B)]Blowdown valve
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Benedum B-3.Blowdown valve
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]RECIP_Benedum B-3
Reciprocating compressor source [98.236(p)(2)(i)(B)]Isolation valve
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Benedum B-3.Isolation valve
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]RECIP_Benedum B-3
Reciprocating compressor source [98.236(p)(2)(i)(B)]Rod packing
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Benedum B-3.Rod packing
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]RECIP_Benedum B-4
Reciprocating compressor source [98.236(p)(2)(i)(B)]Blowdown valve
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Benedum B-4.Blowdown valve
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]RECIP_Benedum B-4
Reciprocating compressor source [98.236(p)(2)(i)(B)]Isolation valve
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Benedum B-4.Isolation valve
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]RECIP_Benedum B-4
Reciprocating compressor source [98.236(p)(2)(i)(B)]Rod packing
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Benedum B-4.Rod packing
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]RECIP_Benedum B-5
Reciprocating compressor source [98.236(p)(2)(i)(B)]Blowdown valve
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Benedum B-5.Blowdown valve
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]RECIP_Benedum B-5
Reciprocating compressor source [98.236(p)(2)(i)(B)]Isolation valve
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Benedum B-5.Isolation valve
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]RECIP_Benedum B-5
Reciprocating compressor source [98.236(p)(2)(i)(B)]Rod packing
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Benedum B-5.Rod packing
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]RECIP_Edward C-101
Reciprocating compressor source [98.236(p)(2)(i)(B)]Blowdown valve
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Edward C-101.Blowdown valve
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]RECIP_Edward C-101
Reciprocating compressor source [98.236(p)(2)(i)(B)]Isolation valve
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Edward C-101.Isolation valve
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]RECIP_Edward C-101
Reciprocating compressor source [98.236(p)(2)(i)(B)]Rod packing
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Edward C-101.Rod packing
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]RECIP_Edward C-102
Reciprocating compressor source [98.236(p)(2)(i)(B)]Blowdown valve
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Edward C-102.Blowdown valve
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]RECIP_Edward C-102
Reciprocating compressor source [98.236(p)(2)(i)(B)]Isolation valve
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Edward C-102.Isolation valve
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]RECIP_Edward C-102
Reciprocating compressor source [98.236(p)(2)(i)(B)]Rod packing
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Edward C-102.Rod packing
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]RECIP_Edward C-201
Reciprocating compressor source [98.236(p)(2)(i)(B)]Blowdown valve
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Edward C-201.Blowdown valve
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]RECIP_Edward C-201
Reciprocating compressor source [98.236(p)(2)(i)(B)]Isolation valve
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Edward C-201.Isolation valve
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]RECIP_Edward C-201
Reciprocating compressor source [98.236(p)(2)(i)(B)]Rod packing
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Edward C-201.Rod packing
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]RECIP_Edward C-202
Reciprocating compressor source [98.236(p)(2)(i)(B)]Blowdown valve
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Edward C-202.Blowdown valve
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]RECIP_Edward C-202
Reciprocating compressor source [98.236(p)(2)(i)(B)]Isolation valve
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Edward C-202.Isolation valve
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]RECIP_Edward C-202
Reciprocating compressor source [98.236(p)(2)(i)(B)]Rod packing
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Edward C-202.Rod packing
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]RECIP_Edward C-203
Reciprocating compressor source [98.236(p)(2)(i)(B)]Blowdown valve
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Edward C-203.Blowdown valve
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]RECIP_Edward C-203
Reciprocating compressor source [98.236(p)(2)(i)(B)]Isolation valve
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Edward C-203.Isolation valve
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]RECIP_Edward C-203
Reciprocating compressor source [98.236(p)(2)(i)(B)]Rod packing
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Edward C-203.Rod packing
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]RECIP_Edward C-204
Reciprocating compressor source [98.236(p)(2)(i)(B)]Blowdown valve
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Edward C-204.Blowdown valve
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]RECIP_Edward C-204
Reciprocating compressor source [98.236(p)(2)(i)(B)]Isolation valve
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Edward C-204.Isolation valve
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]RECIP_Edward C-204
Reciprocating compressor source [98.236(p)(2)(i)(B)]Rod packing
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Edward C-204.Rod packing
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]RECIP_Edward C-205
Reciprocating compressor source [98.236(p)(2)(i)(B)]Blowdown valve
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Edward C-205.Blowdown valve
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]RECIP_Edward C-205
Reciprocating compressor source [98.236(p)(2)(i)(B)]Isolation valve
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Edward C-205.Isolation valve
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]RECIP_Edward C-205
Reciprocating compressor source [98.236(p)(2)(i)(B)]Rod packing
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Edward C-205.Rod packing
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]RECIP_Edward C-206
Reciprocating compressor source [98.236(p)(2)(i)(B)]Blowdown valve
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Edward C-206.Blowdown valve
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]RECIP_Edward C-206
Reciprocating compressor source [98.236(p)(2)(i)(B)]Isolation valve
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Edward C-206.Isolation valve
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]RECIP_Edward C-206
Reciprocating compressor source [98.236(p)(2)(i)(B)]Rod packing
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Edward C-206.Rod packing
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]RECIP_Edward C-207
Reciprocating compressor source [98.236(p)(2)(i)(B)]Blowdown valve
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Edward C-207.Blowdown valve
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]RECIP_Edward C-207
Reciprocating compressor source [98.236(p)(2)(i)(B)]Isolation valve
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Edward C-207.Isolation valve
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]RECIP_Edward C-207
Reciprocating compressor source [98.236(p)(2)(i)(B)]Rod packing
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Edward C-207.Rod packing
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]RECIP_Edward C-208
Reciprocating compressor source [98.236(p)(2)(i)(B)]Blowdown valve
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Edward C-208.Blowdown valve
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]RECIP_Edward C-208
Reciprocating compressor source [98.236(p)(2)(i)(B)]Isolation valve
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Edward C-208.Isolation valve
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]RECIP_Edward C-208
Reciprocating compressor source [98.236(p)(2)(i)(B)]Rod packing
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Edward C-208.Rod packing
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]RECIP_Edward C-301
Reciprocating compressor source [98.236(p)(2)(i)(B)]Blowdown valve
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Edward C-301.Blowdown valve
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]RECIP_Edward C-301
Reciprocating compressor source [98.236(p)(2)(i)(B)]Isolation valve
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Edward C-301.Isolation valve
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]RECIP_Edward C-301
Reciprocating compressor source [98.236(p)(2)(i)(B)]Rod packing
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Edward C-301.Rod packing
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]RECIP_Edward C-302
Reciprocating compressor source [98.236(p)(2)(i)(B)]Blowdown valve
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Edward C-302.Blowdown valve
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]RECIP_Edward C-302
Reciprocating compressor source [98.236(p)(2)(i)(B)]Isolation valve
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Edward C-302.Isolation valve
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]RECIP_Edward C-302
Reciprocating compressor source [98.236(p)(2)(i)(B)]Rod packing
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Edward C-302.Rod packing
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]RECIP_Edward C-303
Reciprocating compressor source [98.236(p)(2)(i)(B)]Blowdown valve
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Edward C-303.Blowdown valve
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]RECIP_Edward C-303
Reciprocating compressor source [98.236(p)(2)(i)(B)]Isolation valve
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Edward C-303.Isolation valve
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]RECIP_Edward C-303
Reciprocating compressor source [98.236(p)(2)(i)(B)]Rod packing
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Edward C-303.Rod packing
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]RECIP_Edward C-304
Reciprocating compressor source [98.236(p)(2)(i)(B)]Blowdown valve
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Edward C-304.Blowdown valve
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]RECIP_Edward C-304
Reciprocating compressor source [98.236(p)(2)(i)(B)]Isolation valve
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Edward C-304.Isolation valve
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]RECIP_Edward C-304
Reciprocating compressor source [98.236(p)(2)(i)(B)]Rod packing
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Edward C-304.Rod packing
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]RECIP_Edward C-305
Reciprocating compressor source [98.236(p)(2)(i)(B)]Blowdown valve
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Edward C-305.Blowdown valve
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]RECIP_Edward C-305
Reciprocating compressor source [98.236(p)(2)(i)(B)]Isolation valve
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Edward C-305.Isolation valve
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]RECIP_Edward C-305
Reciprocating compressor source [98.236(p)(2)(i)(B)]Rod packing
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Edward C-305.Rod packing
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]RECIP_Edward C-306
Reciprocating compressor source [98.236(p)(2)(i)(B)]Blowdown valve
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Edward C-306.Blowdown valve
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]RECIP_Edward C-306
Reciprocating compressor source [98.236(p)(2)(i)(B)]Isolation valve
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Edward C-306.Isolation valve
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]RECIP_Edward C-306
Reciprocating compressor source [98.236(p)(2)(i)(B)]Rod packing
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Edward C-306.Rod packing
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]RECIP_Edward C-307
Reciprocating compressor source [98.236(p)(2)(i)(B)]Blowdown valve
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Edward C-307.Blowdown valve
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]RECIP_Edward C-307
Reciprocating compressor source [98.236(p)(2)(i)(B)]Isolation valve
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Edward C-307.Isolation valve
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]RECIP_Edward C-307
Reciprocating compressor source [98.236(p)(2)(i)(B)]Rod packing
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Edward C-307.Rod packing
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]RECIP_Joyce C-405
Reciprocating compressor source [98.236(p)(2)(i)(B)]Blowdown valve
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Joyce C-405.Blowdown valve
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]RECIP_Joyce C-405
Reciprocating compressor source [98.236(p)(2)(i)(B)]Isolation valve
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Joyce C-405.Isolation valve
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]RECIP_Joyce C-405
Reciprocating compressor source [98.236(p)(2)(i)(B)]Rod packing
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Joyce C-405.Rod packing
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]RECIP_Joyce C-406
Reciprocating compressor source [98.236(p)(2)(i)(B)]Blowdown valve
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Joyce C-406.Blowdown valve
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]RECIP_Joyce C-406
Reciprocating compressor source [98.236(p)(2)(i)(B)]Isolation valve
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Joyce C-406.Isolation valve
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]RECIP_Joyce C-406
Reciprocating compressor source [98.236(p)(2)(i)(B)]Rod packing
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Joyce C-406.Rod packing
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]RECIP_Joyce C-407
Reciprocating compressor source [98.236(p)(2)(i)(B)]Blowdown valve
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Joyce C-407.Blowdown valve
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]RECIP_Joyce C-407
Reciprocating compressor source [98.236(p)(2)(i)(B)]Isolation valve
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Joyce C-407.Isolation valve
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]RECIP_Joyce C-407
Reciprocating compressor source [98.236(p)(2)(i)(B)]Rod packing
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Joyce C-407.Rod packing
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]RECIP_Joyce C-408
Reciprocating compressor source [98.236(p)(2)(i)(B)]Blowdown valve
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Joyce C-408.Blowdown valve
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]RECIP_Joyce C-408
Reciprocating compressor source [98.236(p)(2)(i)(B)]Isolation valve
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Joyce C-408.Isolation valve
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]RECIP_Joyce C-408
Reciprocating compressor source [98.236(p)(2)(i)(B)]Rod packing
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Joyce C-408.Rod packing
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]RECIP_Joyce C-409
Reciprocating compressor source [98.236(p)(2)(i)(B)]Blowdown valve
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Joyce C-409.Blowdown valve
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]RECIP_Joyce C-409
Reciprocating compressor source [98.236(p)(2)(i)(B)]Isolation valve
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Joyce C-409.Isolation valve
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]RECIP_Joyce C-409
Reciprocating compressor source [98.236(p)(2)(i)(B)]Rod packing
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Joyce C-409.Rod packing
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]RECIP_Joyce C-410
Reciprocating compressor source [98.236(p)(2)(i)(B)]Blowdown valve
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Joyce C-410.Blowdown valve
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]RECIP_Joyce C-410
Reciprocating compressor source [98.236(p)(2)(i)(B)]Isolation valve
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Joyce C-410.Isolation valve
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]RECIP_Joyce C-410
Reciprocating compressor source [98.236(p)(2)(i)(B)]Rod packing
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Joyce C-410.Rod packing
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]RECIP_Joyce C-411
Reciprocating compressor source [98.236(p)(2)(i)(B)]Blowdown valve
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Joyce C-411.Blowdown valve
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]RECIP_Joyce C-411
Reciprocating compressor source [98.236(p)(2)(i)(B)]Isolation valve
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Joyce C-411.Isolation valve
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]RECIP_Joyce C-411
Reciprocating compressor source [98.236(p)(2)(i)(B)]Rod packing
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Joyce C-411.Rod packing
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]RECIP_Joyce C-701
Reciprocating compressor source [98.236(p)(2)(i)(B)]Blowdown valve
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Joyce C-701.Blowdown valve
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]RECIP_Joyce C-701
Reciprocating compressor source [98.236(p)(2)(i)(B)]Isolation valve
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Joyce C-701.Isolation valve
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]RECIP_Joyce C-701
Reciprocating compressor source [98.236(p)(2)(i)(B)]Rod packing
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Joyce C-701.Rod packing
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]RECIP_Joyce C-702
Reciprocating compressor source [98.236(p)(2)(i)(B)]Blowdown valve
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Joyce C-702.Blowdown valve
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]RECIP_Joyce C-702
Reciprocating compressor source [98.236(p)(2)(i)(B)]Isolation valve
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Joyce C-702.Isolation valve
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]RECIP_Joyce C-702
Reciprocating compressor source [98.236(p)(2)(i)(B)]Rod packing
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Joyce C-702.Rod packing
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]RECIP_Joyce C-703
Reciprocating compressor source [98.236(p)(2)(i)(B)]Blowdown valve
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Joyce C-703.Blowdown valve
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]RECIP_Joyce C-703
Reciprocating compressor source [98.236(p)(2)(i)(B)]Isolation valve
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Joyce C-703.Isolation valve
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]RECIP_Joyce C-703
Reciprocating compressor source [98.236(p)(2)(i)(B)]Rod packing
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Joyce C-703.Rod packing
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]RECIP_Joyce C-704
Reciprocating compressor source [98.236(p)(2)(i)(B)]Blowdown valve
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Joyce C-704.Blowdown valve
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]RECIP_Joyce C-704
Reciprocating compressor source [98.236(p)(2)(i)(B)]Isolation valve
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Joyce C-704.Isolation valve
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]RECIP_Joyce C-704
Reciprocating compressor source [98.236(p)(2)(i)(B)]Rod packing
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Joyce C-704.Rod packing
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]RECIP_Joyce C-705
Reciprocating compressor source [98.236(p)(2)(i)(B)]Blowdown valve
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Joyce C-705.Blowdown valve
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]RECIP_Joyce C-705
Reciprocating compressor source [98.236(p)(2)(i)(B)]Isolation valve
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Joyce C-705.Isolation valve
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]RECIP_Joyce C-705
Reciprocating compressor source [98.236(p)(2)(i)(B)]Rod packing
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Joyce C-705.Rod packing
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]RECIP_Joyce C-706
Reciprocating compressor source [98.236(p)(2)(i)(B)]Blowdown valve
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Joyce C-706.Blowdown valve
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]RECIP_Joyce C-706
Reciprocating compressor source [98.236(p)(2)(i)(B)]Isolation valve
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Joyce C-706.Isolation valve
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]RECIP_Joyce C-706
Reciprocating compressor source [98.236(p)(2)(i)(B)]Rod packing
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Joyce C-706.Rod packing


ReciprocatingCompressorsLeakOrVentSampleDataRowDetails:
Unique Name or ID for leak or vent (Specify) [98.236(p)(2)(i)(C)] [98.236(p)(3)(i)(A)]RECIP_Edward C-101.Rod packing
Measurement date (mm/dd/yyyy) [98.236(p)(3)(i)(B)]2020-10-14
Measurement method [98.236(p)(3)(i)(C)]High volume sampler
Measured flow rate (standard cubic feet/hour) [98.236(p)(3)(i)(D)]59.859
Is the measurement location prior to or after commingling with non-compressor emission sources? [98.236(p)(3)(i)(F)]Not manifolded
Compressors in “Operating mode”RECIP_Edward C-101
Unique Name or ID for leak or vent (Specify) [98.236(p)(2)(i)(C)] [98.236(p)(3)(i)(A)]RECIP_Edward C-102.Rod packing
Measurement date (mm/dd/yyyy) [98.236(p)(3)(i)(B)]2020-10-14
Measurement method [98.236(p)(3)(i)(C)]High volume sampler
Measured flow rate (standard cubic feet/hour) [98.236(p)(3)(i)(D)]88.128
Is the measurement location prior to or after commingling with non-compressor emission sources? [98.236(p)(3)(i)(F)]Not manifolded
Compressors in “Operating mode”RECIP_Edward C-102
Unique Name or ID for leak or vent (Specify) [98.236(p)(2)(i)(C)] [98.236(p)(3)(i)(A)]RECIP_Edward C-201.Rod packing
Measurement date (mm/dd/yyyy) [98.236(p)(3)(i)(B)]2020-10-14
Measurement method [98.236(p)(3)(i)(C)]High volume sampler
Measured flow rate (standard cubic feet/hour) [98.236(p)(3)(i)(D)]74.679
Is the measurement location prior to or after commingling with non-compressor emission sources? [98.236(p)(3)(i)(F)]Not manifolded
Compressors in “Operating mode”RECIP_Edward C-201
Unique Name or ID for leak or vent (Specify) [98.236(p)(2)(i)(C)] [98.236(p)(3)(i)(A)]RECIP_Edward C-202.Rod packing
Measurement date (mm/dd/yyyy) [98.236(p)(3)(i)(B)]2020-10-14
Measurement method [98.236(p)(3)(i)(C)]High volume sampler
Measured flow rate (standard cubic feet/hour) [98.236(p)(3)(i)(D)]352.206
Is the measurement location prior to or after commingling with non-compressor emission sources? [98.236(p)(3)(i)(F)]Not manifolded
Compressors in “Operating mode”RECIP_Edward C-202
Unique Name or ID for leak or vent (Specify) [98.236(p)(2)(i)(C)] [98.236(p)(3)(i)(A)]RECIP_Edward C-203.Rod packing
Measurement date (mm/dd/yyyy) [98.236(p)(3)(i)(B)]2020-10-14
Measurement method [98.236(p)(3)(i)(C)]High volume sampler
Measured flow rate (standard cubic feet/hour) [98.236(p)(3)(i)(D)]222.736
Is the measurement location prior to or after commingling with non-compressor emission sources? [98.236(p)(3)(i)(F)]Not manifolded
Compressors in “Operating mode”RECIP_Edward C-203
Unique Name or ID for leak or vent (Specify) [98.236(p)(2)(i)(C)] [98.236(p)(3)(i)(A)]RECIP_Edward C-204.Rod packing
Measurement date (mm/dd/yyyy) [98.236(p)(3)(i)(B)]2020-10-14
Measurement method [98.236(p)(3)(i)(C)]High volume sampler
Measured flow rate (standard cubic feet/hour) [98.236(p)(3)(i)(D)]194.535
Is the measurement location prior to or after commingling with non-compressor emission sources? [98.236(p)(3)(i)(F)]Not manifolded
Compressors in “Operating mode”RECIP_Edward C-204
Unique Name or ID for leak or vent (Specify) [98.236(p)(2)(i)(C)] [98.236(p)(3)(i)(A)]RECIP_Edward C-205.Rod packing
Measurement date (mm/dd/yyyy) [98.236(p)(3)(i)(B)]2020-10-14
Measurement method [98.236(p)(3)(i)(C)]High volume sampler
Measured flow rate (standard cubic feet/hour) [98.236(p)(3)(i)(D)]124.319
Is the measurement location prior to or after commingling with non-compressor emission sources? [98.236(p)(3)(i)(F)]Not manifolded
Compressors in “Operating mode”RECIP_Edward C-205
Unique Name or ID for leak or vent (Specify) [98.236(p)(2)(i)(C)] [98.236(p)(3)(i)(A)]RECIP_Edward C-206.Rod packing
Measurement date (mm/dd/yyyy) [98.236(p)(3)(i)(B)]2020-10-14
Measurement method [98.236(p)(3)(i)(C)]High volume sampler
Measured flow rate (standard cubic feet/hour) [98.236(p)(3)(i)(D)]416.119
Is the measurement location prior to or after commingling with non-compressor emission sources? [98.236(p)(3)(i)(F)]Not manifolded
Compressors in “Operating mode”RECIP_Edward C-206
Unique Name or ID for leak or vent (Specify) [98.236(p)(2)(i)(C)] [98.236(p)(3)(i)(A)]RECIP_Edward C-207.Rod packing
Measurement date (mm/dd/yyyy) [98.236(p)(3)(i)(B)]2020-10-14
Measurement method [98.236(p)(3)(i)(C)]High volume sampler
Measured flow rate (standard cubic feet/hour) [98.236(p)(3)(i)(D)]183.023
Is the measurement location prior to or after commingling with non-compressor emission sources? [98.236(p)(3)(i)(F)]Not manifolded
Compressors in “Operating mode”RECIP_Edward C-207
Unique Name or ID for leak or vent (Specify) [98.236(p)(2)(i)(C)] [98.236(p)(3)(i)(A)]RECIP_Edward C-208.Rod packing
Measurement date (mm/dd/yyyy) [98.236(p)(3)(i)(B)]2020-10-14
Measurement method [98.236(p)(3)(i)(C)]High volume sampler
Measured flow rate (standard cubic feet/hour) [98.236(p)(3)(i)(D)]81.373
Is the measurement location prior to or after commingling with non-compressor emission sources? [98.236(p)(3)(i)(F)]Not manifolded
Compressors in “Operating mode”RECIP_Edward C-208
Unique Name or ID for leak or vent (Specify) [98.236(p)(2)(i)(C)] [98.236(p)(3)(i)(A)]RECIP_Edward C-301.Rod packing
Measurement date (mm/dd/yyyy) [98.236(p)(3)(i)(B)]2020-10-14
Measurement method [98.236(p)(3)(i)(C)]High volume sampler
Measured flow rate (standard cubic feet/hour) [98.236(p)(3)(i)(D)]27.029
Is the measurement location prior to or after commingling with non-compressor emission sources? [98.236(p)(3)(i)(F)]Not manifolded
Compressors in “Operating mode”RECIP_Edward C-301
Unique Name or ID for leak or vent (Specify) [98.236(p)(2)(i)(C)] [98.236(p)(3)(i)(A)]RECIP_Edward C-302.Rod packing
Measurement date (mm/dd/yyyy) [98.236(p)(3)(i)(B)]2020-10-14
Measurement method [98.236(p)(3)(i)(C)]High volume sampler
Measured flow rate (standard cubic feet/hour) [98.236(p)(3)(i)(D)]7.028
Is the measurement location prior to or after commingling with non-compressor emission sources? [98.236(p)(3)(i)(F)]Not manifolded
Compressors in “Operating mode”RECIP_Edward C-302
Unique Name or ID for leak or vent (Specify) [98.236(p)(2)(i)(C)] [98.236(p)(3)(i)(A)]RECIP_Edward C-303.Rod packing
Measurement date (mm/dd/yyyy) [98.236(p)(3)(i)(B)]2020-10-14
Measurement method [98.236(p)(3)(i)(C)]High volume sampler
Measured flow rate (standard cubic feet/hour) [98.236(p)(3)(i)(D)]204.879
Is the measurement location prior to or after commingling with non-compressor emission sources? [98.236(p)(3)(i)(F)]Not manifolded
Compressors in “Operating mode”RECIP_Edward C-303
Unique Name or ID for leak or vent (Specify) [98.236(p)(2)(i)(C)] [98.236(p)(3)(i)(A)]RECIP_Edward C-304.Rod packing
Measurement date (mm/dd/yyyy) [98.236(p)(3)(i)(B)]2020-10-14
Measurement method [98.236(p)(3)(i)(C)]High volume sampler
Measured flow rate (standard cubic feet/hour) [98.236(p)(3)(i)(D)]128.463
Is the measurement location prior to or after commingling with non-compressor emission sources? [98.236(p)(3)(i)(F)]Not manifolded
Compressors in “Operating mode”RECIP_Edward C-304
Unique Name or ID for leak or vent (Specify) [98.236(p)(2)(i)(C)] [98.236(p)(3)(i)(A)]RECIP_Edward C-305.Rod packing
Measurement date (mm/dd/yyyy) [98.236(p)(3)(i)(B)]2020-10-14
Measurement method [98.236(p)(3)(i)(C)]High volume sampler
Measured flow rate (standard cubic feet/hour) [98.236(p)(3)(i)(D)]139.469
Is the measurement location prior to or after commingling with non-compressor emission sources? [98.236(p)(3)(i)(F)]Not manifolded
Compressors in “Operating mode”RECIP_Edward C-305
Unique Name or ID for leak or vent (Specify) [98.236(p)(2)(i)(C)] [98.236(p)(3)(i)(A)]RECIP_Edward C-306.Rod packing
Measurement date (mm/dd/yyyy) [98.236(p)(3)(i)(B)]2020-10-14
Measurement method [98.236(p)(3)(i)(C)]High volume sampler
Measured flow rate (standard cubic feet/hour) [98.236(p)(3)(i)(D)]40.543
Is the measurement location prior to or after commingling with non-compressor emission sources? [98.236(p)(3)(i)(F)]Not manifolded
Compressors in “Operating mode”RECIP_Edward C-306
Unique Name or ID for leak or vent (Specify) [98.236(p)(2)(i)(C)] [98.236(p)(3)(i)(A)]RECIP_Edward C-307.Rod packing
Measurement date (mm/dd/yyyy) [98.236(p)(3)(i)(B)]2020-10-14
Measurement method [98.236(p)(3)(i)(C)]High volume sampler
Measured flow rate (standard cubic feet/hour) [98.236(p)(3)(i)(D)]94.061
Is the measurement location prior to or after commingling with non-compressor emission sources? [98.236(p)(3)(i)(F)]Not manifolded
Compressors in “Operating mode”RECIP_Edward C-307


ReciprocatingCompressorsEmissionFactorsSampleDataRowDetails:
Compressor Mode [98.236(p)(3)(ii)(A)]Operating
Compressor Source [98.236(p)(3)(ii)(A)]Blowdown valve
Compressor mode-source combination reporter emission factor, EFs,m (standard cubic feet per hour) [98.236(p)(3)(ii)(B)]10.90454369
Total number of compressors measured in the compressor mode-source combination in current reporting year and preceding two reporting years, Countm [98.236(p)(3)(ii)(C)]412
Is the reporter emission factor facility-specific or based on all of the reporter's applicable facilities? [98.236(p)(3)(ii)(D)]All applicable facilities
Compressor Mode [98.236(p)(3)(ii)(A)]Operating
Compressor Source [98.236(p)(3)(ii)(A)]Rod packing
Compressor mode-source combination reporter emission factor, EFs,m (standard cubic feet per hour) [98.236(p)(3)(ii)(B)]81.92604592
Total number of compressors measured in the compressor mode-source combination in current reporting year and preceding two reporting years, Countm [98.236(p)(3)(ii)(C)]588
Is the reporter emission factor facility-specific or based on all of the reporter's applicable facilities? [98.236(p)(3)(ii)(D)]All applicable facilities
Compressor Mode [98.236(p)(3)(ii)(A)]Standby-pressurized
Compressor Source [98.236(p)(3)(ii)(A)]Blowdown valve
Compressor mode-source combination reporter emission factor, EFs,m (standard cubic feet per hour) [98.236(p)(3)(ii)(B)]9.45780303
Total number of compressors measured in the compressor mode-source combination in current reporting year and preceding two reporting years, Countm [98.236(p)(3)(ii)(C)]132
Is the reporter emission factor facility-specific or based on all of the reporter's applicable facilities? [98.236(p)(3)(ii)(D)]All applicable facilities
Compressor Mode [98.236(p)(3)(ii)(A)]Not-operating-depressurized
Compressor Source [98.236(p)(3)(ii)(A)]Isolation valve
Compressor mode-source combination reporter emission factor, EFs,m (standard cubic feet per hour) [98.236(p)(3)(ii)(B)]96.14192818
Total number of compressors measured in the compressor mode-source combination in current reporting year and preceding two reporting years, Countm [98.236(p)(3)(ii)(C)]181
Is the reporter emission factor facility-specific or based on all of the reporter's applicable facilities? [98.236(p)(3)(ii)(D)]All applicable facilities


ReciprocatingCompressorsLeakOrVentDataRowDetails:
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Benedum B-1R.Blowdown valve
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]No
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)]0
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)]0
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Benedum B-1R.Isolation valve
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]No
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)]0
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)]0
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Benedum B-1R.Rod packing
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]No
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)]0
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)]0
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Benedum B-2.Blowdown valve
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]No
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)]0
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)]0
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Benedum B-2.Isolation valve
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]No
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)]0
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)]0
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Benedum B-2.Rod packing
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]No
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)]0
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)]0
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Benedum B-3.Blowdown valve
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]No
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)]0
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)]0
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Benedum B-3.Isolation valve
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]No
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)]0
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)]0
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Benedum B-3.Rod packing
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]No
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)]0
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)]0
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Benedum B-4.Blowdown valve
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]No
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)]0
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)]0
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Benedum B-4.Isolation valve
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]No
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)]0
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)]0
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Benedum B-4.Rod packing
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]No
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)]0
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)]0
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Benedum B-5.Blowdown valve
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]No
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)]0
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)]0
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Benedum B-5.Isolation valve
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]No
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)]0
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)]0
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Benedum B-5.Rod packing
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]No
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)]0
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)]0
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Edward C-101.Blowdown valve
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Flare
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]No
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
Percentage of time the device was operational when compressor source emissions were routed to device [98.236(p)(2)(ii)(E)]100
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Edward C-101.Isolation valve
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Flare
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]No
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
Percentage of time the device was operational when compressor source emissions were routed to device [98.236(p)(2)(ii)(E)]100
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Edward C-101.Rod packing
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]Yes
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)]0.24445223687592
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)]6.715225886976
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Edward C-102.Blowdown valve
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Flare
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]No
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
Percentage of time the device was operational when compressor source emissions were routed to device [98.236(p)(2)(ii)(E)]100
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Edward C-102.Isolation valve
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Flare
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]No
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
Percentage of time the device was operational when compressor source emissions were routed to device [98.236(p)(2)(ii)(E)]100
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Edward C-102.Rod packing
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]Yes
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)]0.34114693732992
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)]9.371477938176
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Edward C-201.Blowdown valve
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Flare
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]No
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
Percentage of time the device was operational when compressor source emissions were routed to device [98.236(p)(2)(ii)(E)]100
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Edward C-201.Isolation valve
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Flare
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]No
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
Percentage of time the device was operational when compressor source emissions were routed to device [98.236(p)(2)(ii)(E)]100
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Edward C-201.Rod packing
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]Yes
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)]0.31526190015012
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)]8.660402948736
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Edward C-202.Blowdown valve
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Flare
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]No
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
Percentage of time the device was operational when compressor source emissions were routed to device [98.236(p)(2)(ii)(E)]100
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Edward C-202.Isolation valve
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Flare
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]No
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
Percentage of time the device was operational when compressor source emissions were routed to device [98.236(p)(2)(ii)(E)]100
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Edward C-202.Rod packing
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]Yes
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)]1.50195387378456
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)]41.259428275968
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Edward C-203.Blowdown valve
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Flare
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]No
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
Percentage of time the device was operational when compressor source emissions were routed to device [98.236(p)(2)(ii)(E)]100
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Edward C-203.Isolation valve
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Flare
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]No
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
Percentage of time the device was operational when compressor source emissions were routed to device [98.236(p)(2)(ii)(E)]100
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Edward C-203.Rod packing
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]Yes
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)]0.95483992885184
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)]26.229933053952
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Edward C-204.Blowdown valve
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Flare
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]No
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
Percentage of time the device was operational when compressor source emissions were routed to device [98.236(p)(2)(ii)(E)]100
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Edward C-204.Isolation valve
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Flare
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]No
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
Percentage of time the device was operational when compressor source emissions were routed to device [98.236(p)(2)(ii)(E)]100
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Edward C-204.Rod packing
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]Yes
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)]0.8135985441969
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)]22.34996118432
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Edward C-205.Blowdown valve
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Flare
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]No
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
Percentage of time the device was operational when compressor source emissions were routed to device [98.236(p)(2)(ii)(E)]100
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Edward C-205.Isolation valve
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Flare
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]No
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
Percentage of time the device was operational when compressor source emissions were routed to device [98.236(p)(2)(ii)(E)]100
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Edward C-205.Rod packing
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]Yes
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)]0.5290065351012
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)]14.53207556736
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Edward C-206.Blowdown valve
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Flare
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]No
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
Percentage of time the device was operational when compressor source emissions were routed to device [98.236(p)(2)(ii)(E)]100
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Edward C-206.Isolation valve
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Flare
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]No
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
Percentage of time the device was operational when compressor source emissions were routed to device [98.236(p)(2)(ii)(E)]100
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Edward C-206.Rod packing
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]Yes
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)]1.76834861514322
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)]48.577425796416
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Edward C-207.Blowdown valve
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Flare
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]No
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
Percentage of time the device was operational when compressor source emissions were routed to device [98.236(p)(2)(ii)(E)]100
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Edward C-207.Isolation valve
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Flare
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]No
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
Percentage of time the device was operational when compressor source emissions were routed to device [98.236(p)(2)(ii)(E)]100
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Edward C-207.Rod packing
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]Yes
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)]0.74640228651458
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)]20.504046191424
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Edward C-208.Blowdown valve
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Flare
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]No
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
Percentage of time the device was operational when compressor source emissions were routed to device [98.236(p)(2)(ii)(E)]100
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Edward C-208.Isolation valve
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Flare
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]No
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
Percentage of time the device was operational when compressor source emissions were routed to device [98.236(p)(2)(ii)(E)]100
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Edward C-208.Rod packing
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]Yes
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)]0.28581082110104
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)]7.851366995712
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Edward C-301.Blowdown valve
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Flare
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]No
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
Percentage of time the device was operational when compressor source emissions were routed to device [98.236(p)(2)(ii)(E)]100
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Edward C-301.Isolation valve
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Flare
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]No
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
Percentage of time the device was operational when compressor source emissions were routed to device [98.236(p)(2)(ii)(E)]100
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Edward C-301.Rod packing
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]Yes
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)]0.00212462643776
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)]3.65157849388032
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Edward C-302.Blowdown valve
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Flare
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]No
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
Percentage of time the device was operational when compressor source emissions were routed to device [98.236(p)(2)(ii)(E)]100
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Edward C-302.Isolation valve
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Flare
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]No
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
Percentage of time the device was operational when compressor source emissions were routed to device [98.236(p)(2)(ii)(E)]100
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Edward C-302.Rod packing
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]Yes
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)]0.00059975715072
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)]1.03079782600704
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Edward C-303.Blowdown valve
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Flare
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]No
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
Percentage of time the device was operational when compressor source emissions were routed to device [98.236(p)(2)(ii)(E)]100
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Edward C-303.Isolation valve
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Flare
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]No
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
Percentage of time the device was operational when compressor source emissions were routed to device [98.236(p)(2)(ii)(E)]100
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Edward C-303.Rod packing
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]Yes
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)]0.01750556654376
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)]30.0866774404723
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Edward C-304.Blowdown valve
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Flare
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]No
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
Percentage of time the device was operational when compressor source emissions were routed to device [98.236(p)(2)(ii)(E)]100
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Edward C-304.Isolation valve
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Flare
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]No
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
Percentage of time the device was operational when compressor source emissions were routed to device [98.236(p)(2)(ii)(E)]100
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Edward C-304.Rod packing
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]Yes
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)]0.010676303004
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)]18.349276724928
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Edward C-305.Blowdown valve
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Flare
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]No
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
Percentage of time the device was operational when compressor source emissions were routed to device [98.236(p)(2)(ii)(E)]100
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Edward C-305.Isolation valve
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Flare
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]No
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
Percentage of time the device was operational when compressor source emissions were routed to device [98.236(p)(2)(ii)(E)]100
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Edward C-305.Rod packing
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]Yes
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)]0.01206636694912
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)]20.7383685280358
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Edward C-306.Blowdown valve
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Flare
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]No
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
Percentage of time the device was operational when compressor source emissions were routed to device [98.236(p)(2)(ii)(E)]100
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Edward C-306.Isolation valve
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Flare
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]No
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
Percentage of time the device was operational when compressor source emissions were routed to device [98.236(p)(2)(ii)(E)]100
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Edward C-306.Rod packing
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]Yes
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)]0.00343171844856
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)]5.89806709598592
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Edward C-307.Blowdown valve
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Flare
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]No
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
Percentage of time the device was operational when compressor source emissions were routed to device [98.236(p)(2)(ii)(E)]100
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Edward C-307.Isolation valve
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Flare
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]No
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
Percentage of time the device was operational when compressor source emissions were routed to device [98.236(p)(2)(ii)(E)]100
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Edward C-307.Rod packing
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]Yes
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)]0.0065011577004
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)]11.1734878292928
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Joyce C-405.Blowdown valve
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Flare
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]No
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
Percentage of time the device was operational when compressor source emissions were routed to device [98.236(p)(2)(ii)(E)]100
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Joyce C-405.Isolation valve
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Flare
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]No
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
Percentage of time the device was operational when compressor source emissions were routed to device [98.236(p)(2)(ii)(E)]100
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Joyce C-405.Rod packing
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]No
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)]0.341215907259756
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)]9.37337257683496
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Joyce C-406.Blowdown valve
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Flare
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]No
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
Percentage of time the device was operational when compressor source emissions were routed to device [98.236(p)(2)(ii)(E)]100
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Joyce C-406.Isolation valve
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Flare
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]No
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
Percentage of time the device was operational when compressor source emissions were routed to device [98.236(p)(2)(ii)(E)]100
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Joyce C-406.Rod packing
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]No
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)]0.334862260573062
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)]9.19883470697352
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Joyce C-407.Blowdown valve
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Flare
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]No
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
Percentage of time the device was operational when compressor source emissions were routed to device [98.236(p)(2)(ii)(E)]100
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Joyce C-407.Isolation valve
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Flare
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]No
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
Percentage of time the device was operational when compressor source emissions were routed to device [98.236(p)(2)(ii)(E)]100
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Joyce C-407.Rod packing
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]No
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)]0.344727133060297
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)]9.46982771544259
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Joyce C-408.Blowdown valve
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Flare
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]No
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
Percentage of time the device was operational when compressor source emissions were routed to device [98.236(p)(2)(ii)(E)]100
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Joyce C-408.Isolation valve
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Flare
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]No
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
Percentage of time the device was operational when compressor source emissions were routed to device [98.236(p)(2)(ii)(E)]100
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Joyce C-408.Rod packing
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]No
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)]0.342093713709891
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)]9.39748636148687
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Joyce C-409.Blowdown valve
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Flare
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]No
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
Percentage of time the device was operational when compressor source emissions were routed to device [98.236(p)(2)(ii)(E)]100
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Joyce C-409.Isolation valve
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Flare
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]No
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
Percentage of time the device was operational when compressor source emissions were routed to device [98.236(p)(2)(ii)(E)]100
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Joyce C-409.Rod packing
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]No
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)]0.323826979485646
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)]8.89568998563524
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Joyce C-410.Blowdown valve
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Flare
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]No
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
Percentage of time the device was operational when compressor source emissions were routed to device [98.236(p)(2)(ii)(E)]100
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Joyce C-410.Isolation valve
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Flare
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]No
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
Percentage of time the device was operational when compressor source emissions were routed to device [98.236(p)(2)(ii)(E)]100
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Joyce C-410.Rod packing
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]No
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)]0.34272071831713
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)]9.41471049338109
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Joyce C-411.Blowdown valve
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Flare
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]No
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
Percentage of time the device was operational when compressor source emissions were routed to device [98.236(p)(2)(ii)(E)]100
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Joyce C-411.Isolation valve
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Flare
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]No
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
Percentage of time the device was operational when compressor source emissions were routed to device [98.236(p)(2)(ii)(E)]100
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Joyce C-411.Rod packing
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]No
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)]0.33795548330211
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)]9.28380709098501
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Joyce C-701.Blowdown valve
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Flare
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]No
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
Percentage of time the device was operational when compressor source emissions were routed to device [98.236(p)(2)(ii)(E)]100
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Joyce C-701.Isolation valve
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Flare
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]No
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
Percentage of time the device was operational when compressor source emissions were routed to device [98.236(p)(2)(ii)(E)]100
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Joyce C-701.Rod packing
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]No
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)]0
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)]11.5012518981195
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Joyce C-702.Blowdown valve
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Flare
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]No
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
Percentage of time the device was operational when compressor source emissions were routed to device [98.236(p)(2)(ii)(E)]100
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Joyce C-702.Isolation valve
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Flare
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]No
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
Percentage of time the device was operational when compressor source emissions were routed to device [98.236(p)(2)(ii)(E)]100
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Joyce C-702.Rod packing
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]No
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)]0
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)]12.0465053092833
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Joyce C-703.Blowdown valve
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Flare
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]No
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
Percentage of time the device was operational when compressor source emissions were routed to device [98.236(p)(2)(ii)(E)]100
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Joyce C-703.Isolation valve
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Flare
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]No
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
Percentage of time the device was operational when compressor source emissions were routed to device [98.236(p)(2)(ii)(E)]100
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Joyce C-703.Rod packing
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]No
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)]0
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)]12.3895356146583
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Joyce C-704.Blowdown valve
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Flare
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]No
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
Percentage of time the device was operational when compressor source emissions were routed to device [98.236(p)(2)(ii)(E)]100
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Joyce C-704.Isolation valve
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Flare
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]No
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
Percentage of time the device was operational when compressor source emissions were routed to device [98.236(p)(2)(ii)(E)]100
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Joyce C-704.Rod packing
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]No
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)]0
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)]11.8577637438805
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Joyce C-705.Blowdown valve
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Flare
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]No
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
Percentage of time the device was operational when compressor source emissions were routed to device [98.236(p)(2)(ii)(E)]100
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Joyce C-705.Isolation valve
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Flare
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]No
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
Percentage of time the device was operational when compressor source emissions were routed to device [98.236(p)(2)(ii)(E)]100
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Joyce C-705.Rod packing
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]No
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)]0
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)]12.4928940909504
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Joyce C-706.Blowdown valve
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Flare
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]No
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
Percentage of time the device was operational when compressor source emissions were routed to device [98.236(p)(2)(ii)(E)]100
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Joyce C-706.Isolation valve
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Flare
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]No
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
Percentage of time the device was operational when compressor source emissions were routed to device [98.236(p)(2)(ii)(E)]100
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_Joyce C-706.Rod packing
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]No
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)]0
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)]11.7873601440873


OtherEmissionsFromEquipmentLeaksDetails:
mt CO25.5225745030304
mt CH4151.70789901312
Did this facility use leak surveys to calculate emissions from equipment leaks in accordance with 98.232 [per 98.236(q)]?Yes
Were missing data procedures used for any parameters to calculate GHG emissions? [98.235]No
Number of complete equipment leak surveys performed during the calendar year [98.236(q)(1)(i)]1
Optical gas imaging instrument as specified in §60.18 [98.234(a)(1)]Yes
Method 21 [98.234(a)(2)]No
Infrared laser beam illuminated instrument [98.234(a)(3)]No
Acoustic leak detection device [98.234(a)(5)]No
Optical gas imaging instrument as specified in §60.5397a [98.234(a)(6)]No
Method 21 as specified in §60.5397a [98.234(a)(7)]No


GasProcessingEmissionsFactorsRowDetails:
Component Type [98.236(q)(2)(i)]Compressor Components, Gas Service - Connector
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)]27
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)]8784
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)]0.6764339204064
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)]18.58197998592
Component Type [98.236(q)(2)(i)]Compressor Components, Gas Service - Meter
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)]0
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)]8784
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)]0
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)]0
Component Type [98.236(q)(2)(i)]Compressor Components, Gas Service - Open-ended Line
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)]0
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)]8784
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)]0
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)]0
Component Type [98.236(q)(2)(i)]Compressor Components, Gas Service - Pressure Relief Valve
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)]5
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)]8784
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)]0.888735482784
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)]24.4140106752
Component Type [98.236(q)(2)(i)]Compressor Components, Gas Service - Valve
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)]38
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)]8784
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)]2.5273611369216
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)]69.42788149248
Component Type [98.236(q)(2)(i)]Non-Compressor Components, Gas Service - Connector
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)]40
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)]8784
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)]1.023636834432
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)]28.1198186496
Component Type [98.236(q)(2)(i)]Non-Compressor components, Gas Service - Meter
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)]3
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)]8784
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)]0.0393947800992
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)]1.08219442176
Component Type [98.236(q)(2)(i)]Non-Compressor Components, Gas Service - Open-ended Line
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)]1
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)]8784
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)]0.0505095758496
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)]1.38752345088
Component Type [98.236(q)(2)(i)]Non-Compressor components, Gas Service - Pressure Relief Valve
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)]0
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)]8784
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)]0
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)]0
Component Type [98.236(q)(2)(i)]Non-Compressor Components, Gas Service - Valve
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)]11
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)]8784
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)]0.3165027725376
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)]8.69449033728