Facility Name:SHERHAN GAS PLANT
Facility Identifier:
Facility Reporting Year:2020
Facility Location:
Address: 20 MI N OF GRUVER ON TX 136
City: GRUVER
State: TX
Postal Code: 79040

Facility Site Details:
CO2 equivalent emissions from facility subparts C-II, SS, and TT (metric tons):72,840.6
CO2 equivalent emissions from supplier subparts LL-QQ (metric tons):
Biogenic CO2 emissions from facility subparts C-II, SS, and TT (metric tons):0
Cogeneration Unit Emissions Indicator:N
GHG Report Start Date:2020-01-01
GHG Report End Date:2020-12-31
Description of Changes to Calculation Methodology:
Plant Code Indicator:N
Primary NAICS Code:211130
Second Primary NAICS Code:

Parent Company Details:
Parent Company Name:DCP MIDSTREAM LP
Address:370 17th Street, Suite 2500, Denver,  CO 80202
Percent Ownership Interest:100

Subpart C: General Stationary Fuel Combustion

Gas Information Details

Gas NameBiogenic Carbon dioxide
Gas Quantity0 (Metric Tons)
Own Result?

Gas NameMethane
Gas Quantity1.17 (Metric Tons)
Own Result?

Gas NameNitrous Oxide
Gas Quantity0.117 (Metric Tons)
Own Result?

Gas NameCarbon Dioxide
Gas Quantity62,209.3 (Metric Tons)
Own Result?

Unit Details:
Unit Name : CP-Id: 99981-00 (GHG Only)
Unit Description :
Common Pipe Details:
Use Ivt Indicator: Y
Maximum Rated Heat Input Capacity: 47.35
Cumulative Maximum Rated Heat Input Capacity: 204.81

Emission Details:
Annual Biogenic CO2 Emissions: 0 (metric tons)
Annual Fossil fuel based CO2 Emissions: 62209.3 (metric tons)

Tier Fuel Details:
Fuel : Natural Gas (Weighted U.S. Average)
Tier Name : Tier 2 (Equation C-2a)
Tier Methodology Start Date : 2020-01-01
Tier Methodology End Date : 2020-12-31
Frequency of HHV determinations : Semiannually

Tier 2 Monthly HHV Details :
JanuaryFebruaryMarchAprilMayJuneJulyAugustSeptemberOctoberNovember
N N N N N N N N N N N

Fuel Emission Details :
Total CO2 emissionsTotal CH4 emissionsTotal N2O emissionsTotal CH4 emissions CO2eTotal N2O emissions CO2e
62209.3 (Metric Tons) 1.17 (Metric Tons) 0.117 (Metric Tons) 29.3 (Metric Tons) 34.9 (Metric Tons)



Subpart W: Petroleum and Natural Gas Systems

Gas Information Details

Gas NameMethane
Gas Quantity86.68 (Metric Tons)
Own Result?

Gas NameCarbon Dioxide
Gas Quantity8,397.7 (Metric Tons)
Own Result?

Gas NameNitrous Oxide
Gas Quantity0.008 (Metric Tons)
Own Result?


SubpartWSummaryDetails:
Industry Segment Number3
Industry Segment NameOnshore natural gas processing [98.230(a)(3)]
Total Reported CO2 Emissions (mt CO2)8397.7
Total CO2e Emissions (mt CO2e)10567.1
Total Reported CH4 Emissions (mt CH4)86.68
Total Reported N2O Emissions (mt N2O)0.008


SubpartWSourceReportingFormRowDetails:
Source Reporting FormCombustion Equipment at Onshore Petroleum and Natural Gas Production Facilities, Onshore Petroleum and Natural Gas Gathering and Boosting Facilities, and Natural gas Distribution Facilities [98.236(z)]
Required for Selected Industry SegmentNo
Total Reported CO2 Emissions (mt CO2)0.0
Total Reported CH4 Emissions (mt CH4)0.00
Total Reported N2O Emissions (mt N2O)0.000
Source Reporting FormFacility Overview [98.236(aa)(2-11)]
Required for Selected Industry SegmentYes
Source Reporting FormWell Testing [98.236(l)]
Required for Selected Industry SegmentNo
Total Reported CO2 Emissions (mt CO2)0
Total Reported CH4 Emissions (mt CH4)0
Total Reported N2O Emissions (mt N2O)0
Source Reporting FormAtmospheric Storage Tanks [98.236(j)]
Required for Selected Industry SegmentNo
Total Reported CO2 Emissions (mt CO2)0.0
Total Reported CH4 Emissions (mt CH4)0.00
Total Reported N2O Emissions (mt N2O)0.000
Source Reporting FormCompletions and Workovers with Hydraulic Fracturing [98.236(g)]
Required for Selected Industry SegmentNo
Total Reported CO2 Emissions (mt CO2)0
Total Reported CH4 Emissions (mt CH4)0
Total Reported N2O Emissions (mt N2O)0
Source Reporting FormWell Venting for Liquids Unloading [98.236(f)]
Required for Selected Industry SegmentNo
Total Reported CO2 Emissions (mt CO2)0.0
Total Reported CH4 Emissions (mt CH4)0
Total Reported N2O Emissions (mt N2O)0
Source Reporting FormNatural Gas Driven Pneumatic Pumps [98.236(c)]
Required for Selected Industry SegmentNo
Total Reported CO2 Emissions (mt CO2)0.0
Total Reported CH4 Emissions (mt CH4)0.00
Total Reported N2O Emissions (mt N2O)0
Source Reporting FormAssociated Gas Venting and Flaring [98.236(m)]
Required for Selected Industry SegmentNo
Total Reported CO2 Emissions (mt CO2)0
Total Reported CH4 Emissions (mt CH4)0
Total Reported N2O Emissions (mt N2O)0
Source Reporting FormAcid Gas Removal Units [98.236(d)]
Required for Selected Industry SegmentYes
Total Reported CO2 Emissions (mt CO2)4455.5
Total Reported CH4 Emissions (mt CH4)0
Total Reported N2O Emissions (mt N2O)0
Source Reporting FormDehydrators [98.236(e)]
Required for Selected Industry SegmentYes
Total Reported CO2 Emissions (mt CO2)0.0
Total Reported CH4 Emissions (mt CH4)0.00
Total Reported N2O Emissions (mt N2O)0.000
Source Reporting FormBlowdown Vent Stacks [98.236(i)]
Required for Selected Industry SegmentYes
Total Reported CO2 Emissions (mt CO2)0.1
Total Reported CH4 Emissions (mt CH4)4.36
Total Reported N2O Emissions (mt N2O)0
Source Reporting FormTransmission Storage Tanks [98.236(k)]
Required for Selected Industry SegmentNo
Total Reported CO2 Emissions (mt CO2)0.0
Total Reported CH4 Emissions (mt CH4)0.00
Total Reported N2O Emissions (mt N2O)0.000
Source Reporting FormFlare Stacks [98.236(n)]
Required for Selected Industry SegmentYes
Total Reported CO2 Emissions (mt CO2)3941.2
Total Reported CH4 Emissions (mt CH4)18.92
Total Reported N2O Emissions (mt N2O)0.008
Source Reporting FormCentrifugal Compressors [98.236(o)]
Required for Selected Industry SegmentYes
Total Reported CO2 Emissions (mt CO2)0.3
Total Reported CH4 Emissions (mt CH4)20.06
Total Reported N2O Emissions (mt N2O)0
Source Reporting FormReciprocating Compressors [98.236(p)]
Required for Selected Industry SegmentYes
Total Reported CO2 Emissions (mt CO2)0.3
Total Reported CH4 Emissions (mt CH4)23.47
Total Reported N2O Emissions (mt N2O)0
Source Reporting FormEquipment Leaks Surveys and Population Counts [98.236(q,r)]
Required for Selected Industry SegmentYes
Total Reported CO2 Emissions (mt CO2)0.3
Total Reported CH4 Emissions (mt CH4)19.87
Total Reported N2O Emissions (mt N2O)0
Source Reporting FormOnshore Production [98.236(aa)(1)]
Required for Selected Industry SegmentNo
Source Reporting FormEnhanced Oil Recovery Injection Pumps [98.236(w)]
Required for Selected Industry SegmentNo
Total Reported CO2 Emissions (mt CO2)0
Total Reported CH4 Emissions (mt CH4)0
Total Reported N2O Emissions (mt N2O)0
Source Reporting FormEnhanced Oil Recovery Hydrocarbon Liquids [98.236(x)]
Required for Selected Industry SegmentNo
Total Reported CO2 Emissions (mt CO2)0
Total Reported CH4 Emissions (mt CH4)0
Total Reported N2O Emissions (mt N2O)0
Source Reporting FormOffshore Petroleum and Natural Gas Production [98.236(s)]
Required for Selected Industry SegmentNo
Total Reported CO2 Emissions (mt CO2)0
Total Reported CH4 Emissions (mt CH4)0
Total Reported N2O Emissions (mt N2O)0
Source Reporting FormNatural Gas Pneumatic Devices [98.236(b)]
Required for Selected Industry SegmentNo
Total Reported CO2 Emissions (mt CO2)0.0
Total Reported CH4 Emissions (mt CH4)0.00
Total Reported N2O Emissions (mt N2O)0


FacilityOverviewDetails:


FacilityOverviewNaturalGasProcessingRowDetails:
Average mole fraction of CH4 in natural gas received [98.236(aa)(3)(v)]0.7427
Average mole fraction of CO2 in natural gas received [98.236(aa)(3)(vi)]0.0038
Does the facility fractionate NGLs? [98.236(aa)(3)(vii)]No


AcidGasRemovalUnitsDetails:
mt CO24455.5
mt CH40
mt N2O0
Did the Facility have any acid gas removal units that vent directly to the atmosphere, to a flare or engine, or to a sulfur recovery plant subject to reporting under 98.232 [98.236(d)]?Yes
Were missing data procedures used for any parameters to calculate GHG emissions? [98.235]No


AcidMissingAcidDataProcUsedRowDetails:
Unit ID or Name [98.236(d)(1)(i)]Amine (AMINE TREATER) (GHG Only)
Calculation Method 2 emissions [Table D.3]Volume fraction of CO2 used to calculate the annual average fraction of CO2 content in the vent from the acid gas removal unit
Measurement FrequencyQuarterly
Number of quarters missing data procedures were used [98.236(bb)(1)]3
Procedures used [98.235(h)]Used previous quarter's analysis.


AcidGasInfoRowDetails:
Unit ID or Name [98.236(d)(1)(i)]Amine (AMINE TREATER) (GHG Only)
Total feed rate entering the acid gas removal unit for the year (million cubic feet) [98.236(d)(1)(ii)]24915.253
Calculation Method Used (Select from list) [98.236(d)(1)(iii)]Calculation Methodology 2 [98.233(d)(2)]
Are any CO2 emissions from the acid gas removal unit recovered and transferred outside the facility? (Yes / No) [98.236(d)(1)(iv)]No
Total CO2 Emissions (mt CO2) [98.236(d)(1)(v)]4455.5


AcidGasCalcMethod2EmissionsRowDetails:
Unit ID or Name [98.236(d)(1)(i)]Amine (AMINE TREATER) (GHG Only)
Annual average fraction of CO2 content in the vent from the acid gas removal unit, VolCO2 (volumetric fraction) [98.236(d)(2)(i)(A)]0.926
Annual volume of gas vented from the acid gas removal unit, Vs (actual or standard cubic feet) [98.236(d)(2)(i)(B)]91491368.271
Annual volume of gas vented reported on an Actual or Standard basis? [98.236]Standard
Temperature used to calculate volume of gas vented (°F) [98.236]60
Pressure used to calculate volume of gas vented (psi) [98.236]14.7


DehydratorsDetails:
mt CO20.0
mt CH40.00
mt N2O0.000
Did the facility have any glycol dehydrators with annual average daily natural gas throughputs greater than or equal to 0.4MMscfd subject to reporting under 98.232 [98.236(e)]?No
Did the facility have any glycol dehydrators with annual average daily natural gas throughputs less than 0.4MMscfd subject to reporting under 98.232 [98.236(e)]?No
Did the facility have any desiccant dehydrators subject to reporting under 98.232 [98.236(e)]?Yes
Were missing data procedures used for any parameters to calculate GHG emissions? [98.235]No


SmallGlycolDehydrators:
Total Number of Small Glycol Dehydrators [98.236(e)(2)(i)]0
Vapor RecoveryNo
Number of Small Glycol Dehydrators By Vent Control Type, Count [98.236(e)(2)(ii)] [98.236(e)(2)(iv)(A)]0
Dehydrator vents to flares or regenerator firebox/fire tubesNo
Number of Small Glycol Dehydrators By Vent Control Type, Count [98.236(e)(2)(ii)] [98.236(e)(2)(iv)(A)]0
Control devices other than vapor recovery, flare or regenerator firebox/fire tubesNo
Emissions vented to flare or regenerator firebox/fire tubes
Total CO2 Emissions (mt CO2) [98.236(e)(2)(iv)(B)] [98.236(e)(2)(v)(A)]0.0
Total CH4 Emissions (mt CH4) [98.236(e)(2)(iv)(C)] [98.236(e)(2)(v)(B)]0.00
Total N2O Emissions (mt N2O) [98.236(e)(2)(iv)(D)]0.000
Emissions that were not vented to a flare or regenerator firebox/fire tubes
Total CO2 Emissions (mt CO2) [98.236(e)(2)(iv)(B)] [98.236(e)(2)(v)(A)]0.0
Total CH4 Emissions (mt CH4) [98.236(e)(2)(iv)(C)] [98.236(e)(2)(v)(B)]0.00


DessicantDehydrators:
Total Number of Desiccant Dehydrators [98.236(e)(3)(i)]2
Vapor RecoveryNo
Number of Desiccant Dehydrators By Vent Control Type, Count [98.236(e)(3)(i)]0
Dehydrator vents to flares or regenerator firebox/fire tubesNo
Number of Desiccant Dehydrators By Vent Control Type, Count [98.236(e)(3)(i)]0
Control devices other than vapor recovery, flare or regenerator firebox/fire tubesNo
Emissions vented to flare or regenerator firebox/fire tubes
Total CO2 Emissions (mt CO2) [98.236(e)(3)(i)] [98.236(e)(3)(ii)]0.0
Total CH4 Emissions (mt CH4) [98.236(e)(3)(i)] [98.236(e)(3)(iii)]0.00
Total N2O Emissions (mt N2O) [98.236(e)(3)(i)]0.000
Emissions that were not vented to a flare or regenerator firebox/fire tubes
Total CO2 Emissions (mt CO2) [98.236(e)(3)(i)] [98.236(e)(3)(ii)]0.0
Total CH4 Emissions (mt CH4) [98.236(e)(3)(i)] [98.236(e)(3)(iii)]0.00


BlowdownVentStacksDetails:
mt CO20.1
mt CH44.36
mt N2O0
Did the facility have any blowdown vent stacks subject to reporting under 98.232 [98.236(i)]?Yes
Were missing data procedures used for any parameters to calculate GHG emissions? [98.235]No
How were emissions determined? [98.236(i)]Calculated by equipment or event type


BlowdownEquipmentOrEventEmissionsRowDetails:
Equipment or event type [98.236(i)(1)] [98.236(i)(2)]Pipeline venting
Total number of blowdowns for equipment or event type, N [98.236(i)(1)(i)]0
Annual total CO2 emissions for each equipment or event type (mt CO2) [98.236(i)(1)(ii)]0.0
Annual total CH4 emissions for each equipment or event type (mt CH4) [98.236(i)(1)(iii)]0.00
Equipment or event type [98.236(i)(1)] [98.236(i)(2)]Pig launchers and receivers
Total number of blowdowns for equipment or event type, N [98.236(i)(1)(i)]87
Annual total CO2 emissions for each equipment or event type (mt CO2) [98.236(i)(1)(ii)]0.0
Annual total CH4 emissions for each equipment or event type (mt CH4) [98.236(i)(1)(iii)]2.57
Equipment or event type [98.236(i)(1)] [98.236(i)(2)]Facility piping
Total number of blowdowns for equipment or event type, N [98.236(i)(1)(i)]0
Annual total CO2 emissions for each equipment or event type (mt CO2) [98.236(i)(1)(ii)]0.0
Annual total CH4 emissions for each equipment or event type (mt CH4) [98.236(i)(1)(iii)]0.00
Equipment or event type [98.236(i)(1)] [98.236(i)(2)]Compressors
Total number of blowdowns for equipment or event type, N [98.236(i)(1)(i)]256
Annual total CO2 emissions for each equipment or event type (mt CO2) [98.236(i)(1)(ii)]0.0
Annual total CH4 emissions for each equipment or event type (mt CH4) [98.236(i)(1)(iii)]1.79
Equipment or event type [98.236(i)(1)] [98.236(i)(2)]All other equipment with a physical volume greater than or equal 50 cubic feet
Total number of blowdowns for equipment or event type, N [98.236(i)(1)(i)]0
Annual total CO2 emissions for each equipment or event type (mt CO2) [98.236(i)(1)(ii)]0.0
Annual total CH4 emissions for each equipment or event type (mt CH4) [98.236(i)(1)(iii)]0.00
Equipment or event type [98.236(i)(1)] [98.236(i)(2)]Emergency shutdowns
Total number of blowdowns for equipment or event type, N [98.236(i)(1)(i)]0
Annual total CO2 emissions for each equipment or event type (mt CO2) [98.236(i)(1)(ii)]0.0
Annual total CH4 emissions for each equipment or event type (mt CH4) [98.236(i)(1)(iii)]0.00
Equipment or event type [98.236(i)(1)] [98.236(i)(2)]Scrubbers/strainers
Total number of blowdowns for equipment or event type, N [98.236(i)(1)(i)]0
Annual total CO2 emissions for each equipment or event type (mt CO2) [98.236(i)(1)(ii)]0.0
Annual total CH4 emissions for each equipment or event type (mt CH4) [98.236(i)(1)(iii)]0.00


FlareStacksDetails:
mt CO23941.2
mt CH418.92
mt N2O0.008
Did the facility have flare stacks subject to reporting under 98.232 [98.236(n)]?Yes
Were missing data procedures used for any parameters to calculate GHG emissions? [98.235]No


UniqueFlareStacksRowDetails:
Unique Name or ID Number for the Flare Stack [98.236(n)(1)]Flare (FLR 1)
Does the flare stack have a continuous flow monitor on gas to the flare? [98.236(n)(2)]Yes
Does the flare stack have a continuous gas analyzer on gas to the flare? [98.236(n)(3)]No
Were CEMS used to measure CO2 emissions for the flare stack? [98.233(n)(8)] [98.236(n)(12)]No
Volume of gas sent to flare, Vs (standard cubic feet) [98.236(n)(4)]66331159.363
Flare combustion efficiency (decimal value) [98.236(n)(6)]0.98
Mole fraction of CH4 in flare feed gas, XCH4 [98.236(n)(7)]0.7427
Mole fraction of CO2 in flare feed gas, XCO2 [98.236(n)(8)]0.0038
Fraction of feed gas sent to un-lit flare, Zu [98.236(n)(5)]0.000
CO2 emissions (mt CO2) [98.236(n)(9)]3941.2
CH4 Emissions (mt CH4) (Eq. W-19) [98.236(n)(10)]18.92
N2O Emissions (mt N2O) (Eq. W-40) [98.236(n)(11)]0.008


CentrifugalCompressorsDetails:
mt CO20.3
mt CH420.06
Did the facility have any centrifugal compressors subject to reporting under 98.232 [98.236(o)]?Yes
Were missing data procedures used for any parameters to calculate GHG emissions? [98.235]No


CentrifugalCompressorsActivityDataRowDetails:
Compressor ID or Unique Name [98.236(o)(1)(i)]Compressor (C-ENG 6) (GHG Only)
Total time in operating-mode (hours) [98.236(o)(1)(ii)]0
Total time in not-operating-depressurized-mode (hours) [98.236(o)(1)(iii)]8784
Compressor measured in operating-mode? [98.236(o)(1)(iv)]No
Compressor measured in not-operating-depressurized-mode? [98.236(o)(1)(v)]Yes
Compressor had blind flanges installed? [98.236(o)(1)(x)]No
Seal Type (wet or dry) [98.236(o)(1)(xi)]Wet
Number of wet seals [98.236(o)(1)(xii)]2
Power output of compressor driver (hp) [98.236(o)(1)(xiii)]7600
Compressor had scheduled depressurized shutdown during reporting year? [98.236(o)(1)(xiv)]Yes
Compressor ID or Unique Name [98.236(o)(1)(i)]Compressor (C-ENG 36) (GHG Only)
Total time in operating-mode (hours) [98.236(o)(1)(ii)]8649.5
Total time in not-operating-depressurized-mode (hours) [98.236(o)(1)(iii)]134.5
Compressor measured in operating-mode? [98.236(o)(1)(iv)]No
Compressor measured in not-operating-depressurized-mode? [98.236(o)(1)(v)]Yes
Compressor had blind flanges installed? [98.236(o)(1)(x)]No
Seal Type (wet or dry) [98.236(o)(1)(xi)]Wet
Number of wet seals [98.236(o)(1)(xii)]2
Power output of compressor driver (hp) [98.236(o)(1)(xiii)]3600
Compressor had scheduled depressurized shutdown during reporting year? [98.236(o)(1)(xiv)]Yes
Compressor ID or Unique Name [98.236(o)(1)(i)]Compressor (C-ENG 37) (GHG Only)
Total time in operating-mode (hours) [98.236(o)(1)(ii)]8567
Total time in not-operating-depressurized-mode (hours) [98.236(o)(1)(iii)]217
Compressor measured in operating-mode? [98.236(o)(1)(iv)]No
Compressor measured in not-operating-depressurized-mode? [98.236(o)(1)(v)]Yes
Compressor had blind flanges installed? [98.236(o)(1)(x)]No
Seal Type (wet or dry) [98.236(o)(1)(xi)]Wet
Number of wet seals [98.236(o)(1)(xii)]2
Power output of compressor driver (hp) [98.236(o)(1)(xiii)]3600
Compressor had scheduled depressurized shutdown during reporting year? [98.236(o)(1)(xiv)]Yes


CentrifugalCompressorsCompressorSourceRowDetails:
Unique Compressor Name or ID [98.236(o)(2)(i)(A)]Compressor (C-ENG 6) (GHG Only)
Centrifugal compressor source [98.236(o)(2)(i)(B)]Blowdown valve
Unique Name or ID for leak or vent [98.236(o)(2)(i)(C)]ENG-6-B
Unique Compressor Name or ID [98.236(o)(2)(i)(A)]Compressor (C-ENG 6) (GHG Only)
Centrifugal compressor source [98.236(o)(2)(i)(B)]Isolation valve
Unique Name or ID for leak or vent [98.236(o)(2)(i)(C)]ENG-6-ISO
Unique Compressor Name or ID [98.236(o)(2)(i)(A)]Compressor (C-ENG 6) (GHG Only)
Centrifugal compressor source [98.236(o)(2)(i)(B)]Wet seal
Unique Name or ID for leak or vent [98.236(o)(2)(i)(C)]ENG-6-WS
Unique Compressor Name or ID [98.236(o)(2)(i)(A)]Compressor (C-ENG 37) (GHG Only)
Centrifugal compressor source [98.236(o)(2)(i)(B)]Blowdown valve
Unique Name or ID for leak or vent [98.236(o)(2)(i)(C)]ENG-37-B
Unique Compressor Name or ID [98.236(o)(2)(i)(A)]Compressor (C-ENG 37) (GHG Only)
Centrifugal compressor source [98.236(o)(2)(i)(B)]Isolation valve
Unique Name or ID for leak or vent [98.236(o)(2)(i)(C)]ENG-37-ISO
Unique Compressor Name or ID [98.236(o)(2)(i)(A)]Compressor (C-ENG 37) (GHG Only)
Centrifugal compressor source [98.236(o)(2)(i)(B)]Wet seal
Unique Name or ID for leak or vent [98.236(o)(2)(i)(C)]ENG-37-WS
Unique Compressor Name or ID [98.236(o)(2)(i)(A)]Compressor (C-ENG 36) (GHG Only)
Centrifugal compressor source [98.236(o)(2)(i)(B)]Blowdown valve
Unique Name or ID for leak or vent [98.236(o)(2)(i)(C)]ENG-36-B
Unique Compressor Name or ID [98.236(o)(2)(i)(A)]Compressor (C-ENG 36) (GHG Only)
Centrifugal compressor source [98.236(o)(2)(i)(B)]Isolation valve
Unique Name or ID for leak or vent [98.236(o)(2)(i)(C)]ENG-36-ISO
Unique Compressor Name or ID [98.236(o)(2)(i)(A)]Compressor (C-ENG 36) (GHG Only)
Centrifugal compressor source [98.236(o)(2)(i)(B)]Wet seal
Unique Name or ID for leak or vent [98.236(o)(2)(i)(C)]ENG-36-WS


CentrifugalCompressorsLeakOrVentSampleDataRowDetails:
Unique Name or ID for leak or vent (Specify) [98.236(o)(3)(i)(A)]ENG-36-ISO
Measurement date (mm/dd/yyyy) [98.236(o)(3)(i)(B)]2020-08-17
Measurement method [98.236(o)(3)(i)(C)]Screening/Optical gas imaging
Measured flow rate, MTs,m, MTs,g,avg (standard cubic feet/hour) [98.236(o)(3)(i)(D)]0
Is the measurement location prior to or after commingling with non-compressor emission sources? [98.236(o)(3)(i)(F)]Not manifolded
Compressors in “Operating mode”
Compressors in “Not-operating mode”Compressor (C-ENG 36) (GHG Only)
Unique Name or ID for leak or vent (Specify) [98.236(o)(3)(i)(A)]ENG-37-ISO
Measurement date (mm/dd/yyyy) [98.236(o)(3)(i)(B)]2020-08-17
Measurement method [98.236(o)(3)(i)(C)]Screening/Optical gas imaging
Measured flow rate, MTs,m, MTs,g,avg (standard cubic feet/hour) [98.236(o)(3)(i)(D)]0
Is the measurement location prior to or after commingling with non-compressor emission sources? [98.236(o)(3)(i)(F)]Not manifolded
Compressors in “Operating mode”
Compressors in “Not-operating mode”Compressor (C-ENG 37) (GHG Only)
Unique Name or ID for leak or vent (Specify) [98.236(o)(3)(i)(A)]ENG-6-ISO
Measurement date (mm/dd/yyyy) [98.236(o)(3)(i)(B)]2020-08-17
Measurement method [98.236(o)(3)(i)(C)]Screening/Optical gas imaging
Measured flow rate, MTs,m, MTs,g,avg (standard cubic feet/hour) [98.236(o)(3)(i)(D)]0
Is the measurement location prior to or after commingling with non-compressor emission sources? [98.236(o)(3)(i)(F)]Not manifolded
Compressors in “Operating mode”
Compressors in “Not-operating mode”Compressor (C-ENG 6) (GHG Only)


CentrifugalCompressorsEmissionFactorsSampleDataRowDetails:
Compressor Mode [98.236(o)(3)(ii)(A)]Operating
Compressor Source [98.236(o)(3)(ii)(A)]Blowdown valve
Compressor mode-source combination reporter emission factor, EFs,m (standard cubic feet per hour) [98.236(o)(3)(ii)(B)]0.33
Total number of compressors measured in the compressor mode-source combination in current reporting year and preceding two reporting years [98.236(o)(3)(ii)(C)]68
Is the reporter emission factor facility-specific or based on all of the reporter's applicable facilities? [98.236(o)(3)(ii)(D)]All applicable facilities
Compressor Mode [98.236(o)(3)(ii)(A)]Not-operating
Compressor Source [98.236(o)(3)(ii)(A)]Isolation valve
Compressor mode-source combination reporter emission factor, EFs,m (standard cubic feet per hour) [98.236(o)(3)(ii)(B)]14.37
Total number of compressors measured in the compressor mode-source combination in current reporting year and preceding two reporting years [98.236(o)(3)(ii)(C)]45
Is the reporter emission factor facility-specific or based on all of the reporter's applicable facilities? [98.236(o)(3)(ii)(D)]All applicable facilities
Compressor Mode [98.236(o)(3)(ii)(A)]Operating
Compressor Source [98.236(o)(3)(ii)(A)]Wet seal
Compressor mode-source combination reporter emission factor, EFs,m (standard cubic feet per hour) [98.236(o)(3)(ii)(B)]81.39
Total number of compressors measured in the compressor mode-source combination in current reporting year and preceding two reporting years [98.236(o)(3)(ii)(C)]28
Is the reporter emission factor facility-specific or based on all of the reporter's applicable facilities? [98.236(o)(3)(ii)(D)]All applicable facilities


CentrifugalCompressorsLeakOrVentDataRowDetails:
Unique Name or ID for leak or vent [98.236(o)(2)(i)(C)]ENG-36-B
Leak or vent for a single compressor source or a manifolded group? [98.236(o)(2)(ii)(A)] [98.236(o)(1)(vi)]Single
Where are leak or vent emissions released? [98.236(o)(2)(ii)(A)] [98.236(o)(1)(vii) through (ix)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(o)(2)(ii)(B)]No
Were continuous measurements conducted on the leak or vent? [98.236(o)(2)(ii)(C)]No
CO2 emissions vented to atmosphere (mt CO2) [98.236(o)(2)(ii)(D)(1)]0.0006
CH4 emissions vented to atmosphere (mt CH4) [98.236(o)(2)(ii)(D)(2)]0.0407
Unique Name or ID for leak or vent [98.236(o)(2)(i)(C)]ENG-36-ISO
Leak or vent for a single compressor source or a manifolded group? [98.236(o)(2)(ii)(A)] [98.236(o)(1)(vi)]Single
Where are leak or vent emissions released? [98.236(o)(2)(ii)(A)] [98.236(o)(1)(vii) through (ix)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(o)(2)(ii)(B)]Yes
Were continuous measurements conducted on the leak or vent? [98.236(o)(2)(ii)(C)]No
CO2 emissions vented to atmosphere (mt CO2) [98.236(o)(2)(ii)(D)(1)]0.0000
CH4 emissions vented to atmosphere (mt CH4) [98.236(o)(2)(ii)(D)(2)]0.0000
Unique Name or ID for leak or vent [98.236(o)(2)(i)(C)]ENG-36-WS
Leak or vent for a single compressor source or a manifolded group? [98.236(o)(2)(ii)(A)] [98.236(o)(1)(vi)]Single
Where are leak or vent emissions released? [98.236(o)(2)(ii)(A)] [98.236(o)(1)(vii) through (ix)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(o)(2)(ii)(B)]No
Were continuous measurements conducted on the leak or vent? [98.236(o)(2)(ii)(C)]No
CO2 emissions vented to atmosphere (mt CO2) [98.236(o)(2)(ii)(D)(1)]0.1399
CH4 emissions vented to atmosphere (mt CH4) [98.236(o)(2)(ii)(D)(2)]10.0381
Unique Name or ID for leak or vent [98.236(o)(2)(i)(C)]ENG-37-B
Leak or vent for a single compressor source or a manifolded group? [98.236(o)(2)(ii)(A)] [98.236(o)(1)(vi)]Single
Where are leak or vent emissions released? [98.236(o)(2)(ii)(A)] [98.236(o)(1)(vii) through (ix)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(o)(2)(ii)(B)]No
Were continuous measurements conducted on the leak or vent? [98.236(o)(2)(ii)(C)]No
CO2 emissions vented to atmosphere (mt CO2) [98.236(o)(2)(ii)(D)(1)]0.0006
CH4 emissions vented to atmosphere (mt CH4) [98.236(o)(2)(ii)(D)(2)]0.0403
Unique Name or ID for leak or vent [98.236(o)(2)(i)(C)]ENG-37-ISO
Leak or vent for a single compressor source or a manifolded group? [98.236(o)(2)(ii)(A)] [98.236(o)(1)(vi)]Single
Where are leak or vent emissions released? [98.236(o)(2)(ii)(A)] [98.236(o)(1)(vii) through (ix)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(o)(2)(ii)(B)]Yes
Were continuous measurements conducted on the leak or vent? [98.236(o)(2)(ii)(C)]No
CO2 emissions vented to atmosphere (mt CO2) [98.236(o)(2)(ii)(D)(1)]0.0000
CH4 emissions vented to atmosphere (mt CH4) [98.236(o)(2)(ii)(D)(2)]0.0000
Unique Name or ID for leak or vent [98.236(o)(2)(i)(C)]ENG-37-WS
Leak or vent for a single compressor source or a manifolded group? [98.236(o)(2)(ii)(A)] [98.236(o)(1)(vi)]Single
Where are leak or vent emissions released? [98.236(o)(2)(ii)(A)] [98.236(o)(1)(vii) through (ix)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(o)(2)(ii)(B)]No
Were continuous measurements conducted on the leak or vent? [98.236(o)(2)(ii)(C)]No
CO2 emissions vented to atmosphere (mt CO2) [98.236(o)(2)(ii)(D)(1)]0.1386
CH4 emissions vented to atmosphere (mt CH4) [98.236(o)(2)(ii)(D)(2)]9.9424
Unique Name or ID for leak or vent [98.236(o)(2)(i)(C)]ENG-6-B
Leak or vent for a single compressor source or a manifolded group? [98.236(o)(2)(ii)(A)] [98.236(o)(1)(vi)]Single
Where are leak or vent emissions released? [98.236(o)(2)(ii)(A)] [98.236(o)(1)(vii) through (ix)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(o)(2)(ii)(B)]No
Were continuous measurements conducted on the leak or vent? [98.236(o)(2)(ii)(C)]No
CO2 emissions vented to atmosphere (mt CO2) [98.236(o)(2)(ii)(D)(1)]0.0000
CH4 emissions vented to atmosphere (mt CH4) [98.236(o)(2)(ii)(D)(2)]0.0000
Unique Name or ID for leak or vent [98.236(o)(2)(i)(C)]ENG-6-ISO
Leak or vent for a single compressor source or a manifolded group? [98.236(o)(2)(ii)(A)] [98.236(o)(1)(vi)]Single
Where are leak or vent emissions released? [98.236(o)(2)(ii)(A)] [98.236(o)(1)(vii) through (ix)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(o)(2)(ii)(B)]Yes
Were continuous measurements conducted on the leak or vent? [98.236(o)(2)(ii)(C)]No
CO2 emissions vented to atmosphere (mt CO2) [98.236(o)(2)(ii)(D)(1)]0.0000
CH4 emissions vented to atmosphere (mt CH4) [98.236(o)(2)(ii)(D)(2)]0.0000
Unique Name or ID for leak or vent [98.236(o)(2)(i)(C)]ENG-6-WS
Leak or vent for a single compressor source or a manifolded group? [98.236(o)(2)(ii)(A)] [98.236(o)(1)(vi)]Single
Where are leak or vent emissions released? [98.236(o)(2)(ii)(A)] [98.236(o)(1)(vii) through (ix)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(o)(2)(ii)(B)]No
Were continuous measurements conducted on the leak or vent? [98.236(o)(2)(ii)(C)]No
CO2 emissions vented to atmosphere (mt CO2) [98.236(o)(2)(ii)(D)(1)]0.0000
CH4 emissions vented to atmosphere (mt CH4) [98.236(o)(2)(ii)(D)(2)]0.0000


ReciprocatingCompressorsDetails:
mt CO20.3
mt CH423.47
Did the facility have any reciprocating compressors subject to reporting under 98.232 [98.236(p)]?Yes
Were missing data procedures used for any parameters to calculate GHG emissions? [98.235]No


ReciprocatingCompressorsActivityDataRowDetails:
Unique name or ID for reciprocating compressor [98.236(p)(1)(i)]Compressor (Compressor for ENG-38B, 800 hp Superior 8G825, #5 ) (GHG Only)
Total time in operating-mode (hours) [98.236(p)(1)(ii)]2995
Total time in standby-pressurized-mode (hours) [98.236(p)(1)(iii)]289.45
Total time in not-operating-depressurized-mode (hours) [98.236(p)(1)(iv)]5499.55
Compressor measured in operating-mode? [98.236(p)(1)(v)]No
Compressor measured in standby-pressurized-mode? [98.236(p)(1)(vi)]No
Compressor measured in not-operating-depressurized-mode? [98.236(p)(1)(vii)]Yes
Compressor had blind flanges installed? [98.236(p)(1)(xii)]No
Power output of compressor driver (hp) [98.236(p)(1)(xiii)]667
Compressor had scheduled depressurized shutdown during reporting year? [98.236(p)(1)(xiv)]Yes
Unique name or ID for reciprocating compressor [98.236(p)(1)(i)]Compressor (C-ENG 33) (GHG Only)
Total time in operating-mode (hours) [98.236(p)(1)(ii)]2944
Total time in standby-pressurized-mode (hours) [98.236(p)(1)(iii)]292
Total time in not-operating-depressurized-mode (hours) [98.236(p)(1)(iv)]5548
Compressor measured in operating-mode? [98.236(p)(1)(v)]No
Compressor measured in standby-pressurized-mode? [98.236(p)(1)(vi)]No
Compressor measured in not-operating-depressurized-mode? [98.236(p)(1)(vii)]Yes
Compressor had blind flanges installed? [98.236(p)(1)(xii)]No
Power output of compressor driver (hp) [98.236(p)(1)(xiii)]667
Compressor had scheduled depressurized shutdown during reporting year? [98.236(p)(1)(xiv)]Yes
Unique name or ID for reciprocating compressor [98.236(p)(1)(i)]Compressor (C-ENG 32) (GHG Only)
Total time in operating-mode (hours) [98.236(p)(1)(ii)]5885
Total time in standby-pressurized-mode (hours) [98.236(p)(1)(iii)]144.95
Total time in not-operating-depressurized-mode (hours) [98.236(p)(1)(iv)]2754.05
Compressor measured in operating-mode? [98.236(p)(1)(v)]No
Compressor measured in standby-pressurized-mode? [98.236(p)(1)(vi)]No
Compressor measured in not-operating-depressurized-mode? [98.236(p)(1)(vii)]Yes
Compressor had blind flanges installed? [98.236(p)(1)(xii)]No
Power output of compressor driver (hp) [98.236(p)(1)(xiii)]667
Compressor had scheduled depressurized shutdown during reporting year? [98.236(p)(1)(xiv)]Yes
Unique name or ID for reciprocating compressor [98.236(p)(1)(i)]Compressor (C-ENG 31) (GHG Only)
Total time in operating-mode (hours) [98.236(p)(1)(ii)]5894
Total time in standby-pressurized-mode (hours) [98.236(p)(1)(iii)]144.5
Total time in not-operating-depressurized-mode (hours) [98.236(p)(1)(iv)]2745.5
Compressor measured in operating-mode? [98.236(p)(1)(v)]No
Compressor measured in standby-pressurized-mode? [98.236(p)(1)(vi)]No
Compressor measured in not-operating-depressurized-mode? [98.236(p)(1)(vii)]Yes
Compressor had blind flanges installed? [98.236(p)(1)(xii)]No
Power output of compressor driver (hp) [98.236(p)(1)(xiii)]667
Compressor had scheduled depressurized shutdown during reporting year? [98.236(p)(1)(xiv)]Yes


ReciprocatingCompressorSourceRowDetails:
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]Compressor (Compressor for ENG-38B, 800 hp Superior 8G825, #5 ) (GHG Only)
Reciprocating compressor source [98.236(p)(2)(i)(B)]Blowdown valve
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]ENG-38-B
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]Compressor (Compressor for ENG-38B, 800 hp Superior 8G825, #5 ) (GHG Only)
Reciprocating compressor source [98.236(p)(2)(i)(B)]Isolation valve
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]ENG-38-ISO
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]Compressor (Compressor for ENG-38B, 800 hp Superior 8G825, #5 ) (GHG Only)
Reciprocating compressor source [98.236(p)(2)(i)(B)]Rod packing
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]ENG-38-RP
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]Compressor (C-ENG 33) (GHG Only)
Reciprocating compressor source [98.236(p)(2)(i)(B)]Blowdown valve
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]ENG-33-B
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]Compressor (C-ENG 33) (GHG Only)
Reciprocating compressor source [98.236(p)(2)(i)(B)]Isolation valve
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]ENG-33-ISO
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]Compressor (C-ENG 33) (GHG Only)
Reciprocating compressor source [98.236(p)(2)(i)(B)]Rod packing
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]ENG-33-RP
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]Compressor (C-ENG 32) (GHG Only)
Reciprocating compressor source [98.236(p)(2)(i)(B)]Blowdown valve
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]ENG-32-B
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]Compressor (C-ENG 32) (GHG Only)
Reciprocating compressor source [98.236(p)(2)(i)(B)]Isolation valve
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]ENG-32-ISO
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]Compressor (C-ENG 32) (GHG Only)
Reciprocating compressor source [98.236(p)(2)(i)(B)]Rod packing
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]ENG-32-RP
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]Compressor (C-ENG 31) (GHG Only)
Reciprocating compressor source [98.236(p)(2)(i)(B)]Blowdown valve
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]ENG-31-B
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]Compressor (C-ENG 31) (GHG Only)
Reciprocating compressor source [98.236(p)(2)(i)(B)]Isolation valve
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]ENG-31-ISO
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]Compressor (C-ENG 31) (GHG Only)
Reciprocating compressor source [98.236(p)(2)(i)(B)]Rod packing
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]ENG-31-RP


ReciprocatingCompressorsLeakOrVentSampleDataRowDetails:
Unique Name or ID for leak or vent (Specify) [98.236(p)(2)(i)(C)] [98.236(p)(3)(i)(A)]ENG-31-ISO
Measurement date (mm/dd/yyyy) [98.236(p)(3)(i)(B)]2020-08-17
Measurement method [98.236(p)(3)(i)(C)]Screening/Optical gas imaging
Measured flow rate (standard cubic feet/hour) [98.236(p)(3)(i)(D)]0
Is the measurement location prior to or after commingling with non-compressor emission sources? [98.236(p)(3)(i)(F)]Not manifolded
Compressors in “Not-operating mode”Compressor (C-ENG 31) (GHG Only)
Unique Name or ID for leak or vent (Specify) [98.236(p)(2)(i)(C)] [98.236(p)(3)(i)(A)]ENG-32-ISO
Measurement date (mm/dd/yyyy) [98.236(p)(3)(i)(B)]2020-08-17
Measurement method [98.236(p)(3)(i)(C)]Screening/Optical gas imaging
Measured flow rate (standard cubic feet/hour) [98.236(p)(3)(i)(D)]0
Is the measurement location prior to or after commingling with non-compressor emission sources? [98.236(p)(3)(i)(F)]Not manifolded
Compressors in “Not-operating mode”Compressor (C-ENG 32) (GHG Only)
Unique Name or ID for leak or vent (Specify) [98.236(p)(2)(i)(C)] [98.236(p)(3)(i)(A)]ENG-33-ISO
Measurement date (mm/dd/yyyy) [98.236(p)(3)(i)(B)]2020-08-17
Measurement method [98.236(p)(3)(i)(C)]High volume sampler
Measured flow rate (standard cubic feet/hour) [98.236(p)(3)(i)(D)]56.48
Is the measurement location prior to or after commingling with non-compressor emission sources? [98.236(p)(3)(i)(F)]Not manifolded
Compressors in “Not-operating mode”Compressor (C-ENG 33) (GHG Only)
Unique Name or ID for leak or vent (Specify) [98.236(p)(2)(i)(C)] [98.236(p)(3)(i)(A)]ENG-38-ISO
Measurement date (mm/dd/yyyy) [98.236(p)(3)(i)(B)]2020-08-17
Measurement method [98.236(p)(3)(i)(C)]High volume sampler
Measured flow rate (standard cubic feet/hour) [98.236(p)(3)(i)(D)]0
Is the measurement location prior to or after commingling with non-compressor emission sources? [98.236(p)(3)(i)(F)]Not manifolded
Compressors in “Not-operating mode”Compressor (Compressor for ENG-38B, 800 hp Superior 8G825, #5 ) (GHG Only)


ReciprocatingCompressorsEmissionFactorsSampleDataRowDetails:
Compressor Mode [98.236(p)(3)(ii)(A)]Not-operating-depressurized
Compressor Source [98.236(p)(3)(ii)(A)]Isolation valve
Compressor mode-source combination reporter emission factor, EFs,m (standard cubic feet per hour) [98.236(p)(3)(ii)(B)]24.55
Total number of compressors measured in the compressor mode-source combination in current reporting year and preceding two reporting years, Countm [98.236(p)(3)(ii)(C)]224
Is the reporter emission factor facility-specific or based on all of the reporter's applicable facilities? [98.236(p)(3)(ii)(D)]All applicable facilities
Compressor Mode [98.236(p)(3)(ii)(A)]Operating
Compressor Source [98.236(p)(3)(ii)(A)]Blowdown valve
Compressor mode-source combination reporter emission factor, EFs,m (standard cubic feet per hour) [98.236(p)(3)(ii)(B)]2.06
Total number of compressors measured in the compressor mode-source combination in current reporting year and preceding two reporting years, Countm [98.236(p)(3)(ii)(C)]218
Is the reporter emission factor facility-specific or based on all of the reporter's applicable facilities? [98.236(p)(3)(ii)(D)]All applicable facilities
Compressor Mode [98.236(p)(3)(ii)(A)]Standby-pressurized
Compressor Source [98.236(p)(3)(ii)(A)]Blowdown valve
Compressor mode-source combination reporter emission factor, EFs,m (standard cubic feet per hour) [98.236(p)(3)(ii)(B)]1.29
Total number of compressors measured in the compressor mode-source combination in current reporting year and preceding two reporting years, Countm [98.236(p)(3)(ii)(C)]26
Is the reporter emission factor facility-specific or based on all of the reporter's applicable facilities? [98.236(p)(3)(ii)(D)]All applicable facilities
Compressor Mode [98.236(p)(3)(ii)(A)]Operating
Compressor Source [98.236(p)(3)(ii)(A)]Rod packing
Compressor mode-source combination reporter emission factor, EFs,m (standard cubic feet per hour) [98.236(p)(3)(ii)(B)]73.08
Total number of compressors measured in the compressor mode-source combination in current reporting year and preceding two reporting years, Countm [98.236(p)(3)(ii)(C)]458
Is the reporter emission factor facility-specific or based on all of the reporter's applicable facilities? [98.236(p)(3)(ii)(D)]All applicable facilities


ReciprocatingCompressorsLeakOrVentDataRowDetails:
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]ENG-31-B
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]No
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)]0.0
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)]0.18
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]ENG-31-ISO
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]Yes
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)]0.0
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)]0.00
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]ENG-31-RP
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]No
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)]0.1
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)]6.14
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]ENG-32-B
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]No
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)]0.0
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)]0.18
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]ENG-32-ISO
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]Yes
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)]0.0
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)]0.00
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]ENG-32-RP
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]No
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)]0.1
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)]6.13
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]ENG-33-B
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]No
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)]0.0
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)]0.09
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]ENG-33-ISO
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]Yes
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)]0.1
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)]4.47
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]ENG-33-RP
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]No
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)]0.0
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)]3.07
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]ENG-38-B
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]No
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)]0.0
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)]0.09
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]ENG-38-ISO
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]Yes
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)]0.0
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)]0.00
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]ENG-38-RP
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]No
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)]0.0
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)]3.12


OtherEmissionsFromEquipmentLeaksDetails:
mt CO20.3
mt CH419.87
Did this facility use leak surveys to calculate emissions from equipment leaks in accordance with 98.232 [per 98.236(q)]?Yes
Did this facility use population counts to calculate emissions from equipment leaks in accordance with 98.232 [per 98.236(r)]?No
Did the facility elect to comply with 98.236(q) according to 98.233(q)(1)(iv) for any components at the facility [per 98.236(q)(1)(iv)]?No
Were missing data procedures used for any parameters to calculate GHG emissions? [98.235]No
Number of complete equipment leak surveys performed during the calendar year [98.236(q)(1)(i)]1
Optical gas imaging instrument as specified in §60.18 [98.234(a)(1)]Yes
Method 21 [98.234(a)(2)]No
Infrared laser beam illuminated instrument [98.234(a)(3)]No
Acoustic leak detection device [98.234(a)(5)]No
Optical gas imaging instrument as specified in §60.5397a [98.234(a)(6)]No
Method 21 as specified in §60.5397a [98.234(a)(7)]No


GasProcessingEmissionsFactorsRowDetails:
Component Type [98.236(q)(2)(i)]Non-Compressor Components, Gas Service - Connector
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)]0
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)]0
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)]0.0
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)]0.00
Component Type [98.236(q)(2)(i)]Non-Compressor Components, Gas Service - Open-ended Line
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)]0
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)]0
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)]0.0
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)]0.00
Component Type [98.236(q)(2)(i)]Non-Compressor components, Gas Service - Pressure Relief Valve
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)]0
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)]0
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)]0.0
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)]0.00
Component Type [98.236(q)(2)(i)]Non-Compressor components, Gas Service - Meter
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)]0
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)]0
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)]0.0
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)]0.00
Component Type [98.236(q)(2)(i)]Compressor Components, Gas Service - Connector
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)]0
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)]0
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)]0.0
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)]0.00
Component Type [98.236(q)(2)(i)]Compressor Components, Gas Service - Open-ended Line
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)]0
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)]0
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)]0.0
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)]0.00
Component Type [98.236(q)(2)(i)]Compressor Components, Gas Service - Pressure Relief Valve
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)]4
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)]8784
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)]0.3
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)]19.87
Component Type [98.236(q)(2)(i)]Compressor Components, Gas Service - Meter
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)]0
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)]0
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)]0.0
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)]0.00
Component Type [98.236(q)(2)(i)]Non-Compressor Components, Gas Service - Valve
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)]0
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)]0
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)]0.0
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)]0.00
Component Type [98.236(q)(2)(i)]Compressor Components, Gas Service - Valve
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)]0
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)]0
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)]0.0
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)]0.00