Facility Name:PLATTEVILLE GAS PLANT
Facility Identifier:
Facility Reporting Year:2020
Facility Location:
Address: 13675 WELD COUNTY ROAD 34
City: PLATTEVILLE
State: CO
Postal Code: 80651

Facility Site Details:
CO2 equivalent emissions from facility subparts C-II, SS, and TT (metric tons):49,647.2
CO2 equivalent emissions from supplier subparts LL-QQ (metric tons):
Biogenic CO2 emissions from facility subparts C-II, SS, and TT (metric tons):0
Cogeneration Unit Emissions Indicator:N
GHG Report Start Date:2020-01-01
GHG Report End Date:2020-12-31
Description of Changes to Calculation Methodology:
Plant Code Indicator:N
Primary NAICS Code:211130
Second Primary NAICS Code:

Parent Company Details:
Parent Company Name:DCP MIDSTREAM LP
Address:370 17th Street, Suite 2500, Denver,  CO 80202
Percent Ownership Interest:100

Subpart C: General Stationary Fuel Combustion

Gas Information Details

Gas NameBiogenic Carbon dioxide
Gas Quantity0 (Metric Tons)
Own Result?

Gas NameMethane
Gas Quantity0.89 (Metric Tons)
Own Result?

Gas NameNitrous Oxide
Gas Quantity0.089 (Metric Tons)
Own Result?

Gas NameCarbon Dioxide
Gas Quantity47,012.5 (Metric Tons)
Own Result?

Unit Details:
Unit Name : CP-Id: 214663 (GHG Only)
Unit Description :
Common Pipe Details:
Use Ivt Indicator: Y
Maximum Rated Heat Input Capacity: 15
Cumulative Maximum Rated Heat Input Capacity: 125.26

Emission Details:
Annual Biogenic CO2 Emissions: 0 (metric tons)
Annual Fossil fuel based CO2 Emissions: 47012.5 (metric tons)

Tier Fuel Details:
Fuel : Natural Gas (Weighted U.S. Average)
Tier Name : Tier 2 (Equation C-2a)
Tier Methodology Start Date : 2020-01-01
Tier Methodology End Date : 2020-12-31
Frequency of HHV determinations : Other (specify)
Other specified frequency of HHV determinations :

Tier 2 Monthly HHV Details :
JanuaryFebruaryMarchAprilMayJuneJulyAugustSeptemberOctoberNovember
N N N N N N N N N N N

Fuel Emission Details :
Total CO2 emissionsTotal CH4 emissionsTotal N2O emissionsTotal CH4 emissions CO2eTotal N2O emissions CO2e
47012.5 (Metric Tons) 0.89 (Metric Tons) 0.089 (Metric Tons) 22.2 (Metric Tons) 26.4 (Metric Tons)



Subpart W: Petroleum and Natural Gas Systems

Gas Information Details

Gas NameMethane
Gas Quantity83.24 (Metric Tons)
Own Result?

Gas NameCarbon Dioxide
Gas Quantity504.7 (Metric Tons)
Own Result?

Gas NameNitrous Oxide
Gas Quantity0.001 (Metric Tons)
Own Result?


SubpartWSummaryDetails:
Industry Segment Number3
Industry Segment NameOnshore natural gas processing [98.230(a)(3)]
Total Reported CO2 Emissions (mt CO2)504.7
Total CO2e Emissions (mt CO2e)2586.2
Total Reported CH4 Emissions (mt CH4)83.24
Total Reported N2O Emissions (mt N2O)0.001


SubpartWSourceReportingFormRowDetails:
Source Reporting FormCombustion Equipment at Onshore Petroleum and Natural Gas Production Facilities, Onshore Petroleum and Natural Gas Gathering and Boosting Facilities, and Natural gas Distribution Facilities [98.236(z)]
Required for Selected Industry SegmentNo
Total Reported CO2 Emissions (mt CO2)0.0
Total Reported CH4 Emissions (mt CH4)0.00
Total Reported N2O Emissions (mt N2O)0.000
Source Reporting FormFacility Overview [98.236(aa)(2-11)]
Required for Selected Industry SegmentYes
Source Reporting FormWell Testing [98.236(l)]
Required for Selected Industry SegmentNo
Total Reported CO2 Emissions (mt CO2)0
Total Reported CH4 Emissions (mt CH4)0
Total Reported N2O Emissions (mt N2O)0
Source Reporting FormAtmospheric Storage Tanks [98.236(j)]
Required for Selected Industry SegmentNo
Total Reported CO2 Emissions (mt CO2)0.0
Total Reported CH4 Emissions (mt CH4)0.00
Total Reported N2O Emissions (mt N2O)0.000
Source Reporting FormCompletions and Workovers with Hydraulic Fracturing [98.236(g)]
Required for Selected Industry SegmentNo
Total Reported CO2 Emissions (mt CO2)0
Total Reported CH4 Emissions (mt CH4)0
Total Reported N2O Emissions (mt N2O)0
Source Reporting FormWell Venting for Liquids Unloading [98.236(f)]
Required for Selected Industry SegmentNo
Total Reported CO2 Emissions (mt CO2)0.0
Total Reported CH4 Emissions (mt CH4)0
Total Reported N2O Emissions (mt N2O)0
Source Reporting FormNatural Gas Driven Pneumatic Pumps [98.236(c)]
Required for Selected Industry SegmentNo
Total Reported CO2 Emissions (mt CO2)0.0
Total Reported CH4 Emissions (mt CH4)0.00
Total Reported N2O Emissions (mt N2O)0
Source Reporting FormAssociated Gas Venting and Flaring [98.236(m)]
Required for Selected Industry SegmentNo
Total Reported CO2 Emissions (mt CO2)0
Total Reported CH4 Emissions (mt CH4)0
Total Reported N2O Emissions (mt N2O)0
Source Reporting FormAcid Gas Removal Units [98.236(d)]
Required for Selected Industry SegmentYes
Total Reported CO2 Emissions (mt CO2)0.0
Total Reported CH4 Emissions (mt CH4)0
Total Reported N2O Emissions (mt N2O)0
Source Reporting FormDehydrators [98.236(e)]
Required for Selected Industry SegmentYes
Total Reported CO2 Emissions (mt CO2)15.4
Total Reported CH4 Emissions (mt CH4)0.01
Total Reported N2O Emissions (mt N2O)0.000
Source Reporting FormBlowdown Vent Stacks [98.236(i)]
Required for Selected Industry SegmentYes
Total Reported CO2 Emissions (mt CO2)0.2
Total Reported CH4 Emissions (mt CH4)2.52
Total Reported N2O Emissions (mt N2O)0
Source Reporting FormTransmission Storage Tanks [98.236(k)]
Required for Selected Industry SegmentNo
Total Reported CO2 Emissions (mt CO2)0.0
Total Reported CH4 Emissions (mt CH4)0.00
Total Reported N2O Emissions (mt N2O)0.000
Source Reporting FormFlare Stacks [98.236(n)]
Required for Selected Industry SegmentYes
Total Reported CO2 Emissions (mt CO2)482.4
Total Reported CH4 Emissions (mt CH4)5.02
Total Reported N2O Emissions (mt N2O)0.001
Source Reporting FormCentrifugal Compressors [98.236(o)]
Required for Selected Industry SegmentYes
Total Reported CO2 Emissions (mt CO2)0.0
Total Reported CH4 Emissions (mt CH4)0.00
Total Reported N2O Emissions (mt N2O)0
Source Reporting FormReciprocating Compressors [98.236(p)]
Required for Selected Industry SegmentYes
Total Reported CO2 Emissions (mt CO2)4.0
Total Reported CH4 Emissions (mt CH4)44.73
Total Reported N2O Emissions (mt N2O)0
Source Reporting FormEquipment Leaks Surveys and Population Counts [98.236(q,r)]
Required for Selected Industry SegmentYes
Total Reported CO2 Emissions (mt CO2)2.7
Total Reported CH4 Emissions (mt CH4)30.96
Total Reported N2O Emissions (mt N2O)0
Source Reporting FormOnshore Production [98.236(aa)(1)]
Required for Selected Industry SegmentNo
Source Reporting FormEnhanced Oil Recovery Injection Pumps [98.236(w)]
Required for Selected Industry SegmentNo
Total Reported CO2 Emissions (mt CO2)0
Total Reported CH4 Emissions (mt CH4)0
Total Reported N2O Emissions (mt N2O)0
Source Reporting FormEnhanced Oil Recovery Hydrocarbon Liquids [98.236(x)]
Required for Selected Industry SegmentNo
Total Reported CO2 Emissions (mt CO2)0
Total Reported CH4 Emissions (mt CH4)0
Total Reported N2O Emissions (mt N2O)0
Source Reporting FormOffshore Petroleum and Natural Gas Production [98.236(s)]
Required for Selected Industry SegmentNo
Total Reported CO2 Emissions (mt CO2)0
Total Reported CH4 Emissions (mt CH4)0
Total Reported N2O Emissions (mt N2O)0
Source Reporting FormNatural Gas Pneumatic Devices [98.236(b)]
Required for Selected Industry SegmentNo
Total Reported CO2 Emissions (mt CO2)0.0
Total Reported CH4 Emissions (mt CH4)0.00
Total Reported N2O Emissions (mt N2O)0


FacilityOverviewDetails:


FacilityOverviewNaturalGasProcessingRowDetails:
Average mole fraction of CH4 in natural gas received [98.236(aa)(3)(v)]0.7464
Average mole fraction of CO2 in natural gas received [98.236(aa)(3)(vi)]0.0241
Does the facility fractionate NGLs? [98.236(aa)(3)(vii)]No


AcidGasRemovalUnitsDetails:
mt CO20.0
mt CH40
mt N2O0
Did the Facility have any acid gas removal units that vent directly to the atmosphere, to a flare or engine, or to a sulfur recovery plant subject to reporting under 98.232 [98.236(d)]?No
Were missing data procedures used for any parameters to calculate GHG emissions? [98.235]No


DehydratorsDetails:
mt CO215.4
mt CH40.01
mt N2O0.000
Did the facility have any glycol dehydrators with annual average daily natural gas throughputs greater than or equal to 0.4MMscfd subject to reporting under 98.232 [98.236(e)]?Yes
Did the facility have any glycol dehydrators with annual average daily natural gas throughputs less than 0.4MMscfd subject to reporting under 98.232 [98.236(e)]?No
Did the facility have any desiccant dehydrators subject to reporting under 98.232 [98.236(e)]?Yes
Were missing data procedures used for any parameters to calculate GHG emissions? [98.235]No


SmallGlycolDehydrators:
Total Number of Small Glycol Dehydrators [98.236(e)(2)(i)]0
Vapor RecoveryNo
Number of Small Glycol Dehydrators By Vent Control Type, Count [98.236(e)(2)(ii)] [98.236(e)(2)(iv)(A)]0
Dehydrator vents to flares or regenerator firebox/fire tubesNo
Number of Small Glycol Dehydrators By Vent Control Type, Count [98.236(e)(2)(ii)] [98.236(e)(2)(iv)(A)]0
Control devices other than vapor recovery, flare or regenerator firebox/fire tubesNo
Emissions vented to flare or regenerator firebox/fire tubes
Total CO2 Emissions (mt CO2) [98.236(e)(2)(iv)(B)] [98.236(e)(2)(v)(A)]0.0
Total CH4 Emissions (mt CH4) [98.236(e)(2)(iv)(C)] [98.236(e)(2)(v)(B)]0.00
Total N2O Emissions (mt N2O) [98.236(e)(2)(iv)(D)]0.000
Emissions that were not vented to a flare or regenerator firebox/fire tubes
Total CO2 Emissions (mt CO2) [98.236(e)(2)(iv)(B)] [98.236(e)(2)(v)(A)]0.0
Total CH4 Emissions (mt CH4) [98.236(e)(2)(iv)(C)] [98.236(e)(2)(v)(B)]0.00


DessicantDehydrators:
Total Number of Desiccant Dehydrators [98.236(e)(3)(i)]2
Vapor RecoveryNo
Number of Desiccant Dehydrators By Vent Control Type, Count [98.236(e)(3)(i)]0
Dehydrator vents to flares or regenerator firebox/fire tubesNo
Number of Desiccant Dehydrators By Vent Control Type, Count [98.236(e)(3)(i)]0
Control devices other than vapor recovery, flare or regenerator firebox/fire tubesNo
Emissions vented to flare or regenerator firebox/fire tubes
Total CO2 Emissions (mt CO2) [98.236(e)(3)(i)] [98.236(e)(3)(ii)]0.0
Total CH4 Emissions (mt CH4) [98.236(e)(3)(i)] [98.236(e)(3)(iii)]0.00
Total N2O Emissions (mt N2O) [98.236(e)(3)(i)]0.000
Emissions that were not vented to a flare or regenerator firebox/fire tubes
Total CO2 Emissions (mt CO2) [98.236(e)(3)(i)] [98.236(e)(3)(ii)]0.0
Total CH4 Emissions (mt CH4) [98.236(e)(3)(i)] [98.236(e)(3)(iii)]0.00


GlycolDehydratorsMoreThanSpecifiedValueRowDetails:
Unit ID or Name [98.236(e)(1)(i)]GHG (W)GLYDEHY Dehydrator.184
Glycol dehydrator feed natural gas flow rate determined by engineering estimate based on best available data (MMscfd) [98.236(e)(1)(ii)]57.9999839999999
Dehydrator feed natural gas water content (pounds per MMscf) [98.236(e)(1)(iii)]44.85
Dehydrator outlet natural gas water content (pounds per MMscf) [98.236(e)(1)(iv)]0.34
Glycol dehydrator absorbent circulation pump type [98.236(e)(1)(v)]Electric
Dehydrator absorbent circulation rate (gallons per minute) [98.236(e)(1)(vi)]2.45
Report type of absorbent used [98.236(e)(1)(vii)]Ethylene glycol (EG)
Report whether stripper gas is used in glycol dehydrator [98.236(e)(1)(viii)]No
Report whether a flash tank separator is used in glycol dehydrator [98.236(e)(1)(ix)]Yes
Total time the glycol dehydrator is operating (hours) [98.236(e)(1)(x)]8784
Temperature of the wet natural gas (°F) [98.236(e)(1)(xi)]87.16
Pressure of the wet natural gas (psig) [98.236(e)(1)(xii)]863.27
Concentration of CO2 in wet natural gas (mole fraction) [98.236(e)(1)(xiv)]0.0232
Concentration of CH4 in wet natural gas (mole fraction) [98.236(e)(1)(xiii)]0.7380
Were any dehydrator emissions vented to a vapor recovery device? [98.236(e)(1)(xv)]Yes
Were any dehydrator emissions vented to a flare or regenerator firebox/fire tubes? [98.236(e)(1)(xvi)]Yes
CO2 Emissions from Flares or Regenerators (mt CO2) [98.236(e)(1)(xvi)(A)]15.4
CH4 Emissions from Flares or Regenerators (mt CH4) [98.236(e)(1)(xvi)(B)]0.01
N2O Emissions from Flares or Regenerators (mt N2O) [98.236(e)(1)(xvi)(C)]0.000
Were any dehydrator emissions vented to the atmosphere without being routed to a flare or regenerator firebox/fire tubes? [98.236(e)(1)(xvii)]No
CO2 Emissions from Venting (mt CO2) [98.236(e)(1)(xvii)(A)]0.0
CH4 Emissions from Venting (mt CH4) [98.236(e)(1)(xvii)(B)]0.00


BlowdownVentStacksDetails:
mt CO20.2
mt CH42.52
mt N2O0
Did the facility have any blowdown vent stacks subject to reporting under 98.232 [98.236(i)]?Yes
Were missing data procedures used for any parameters to calculate GHG emissions? [98.235]No
How were emissions determined? [98.236(i)]Calculated by equipment or event type


BlowdownEquipmentOrEventEmissionsRowDetails:
Equipment or event type [98.236(i)(1)] [98.236(i)(2)]Pipeline venting
Total number of blowdowns for equipment or event type, N [98.236(i)(1)(i)]0
Annual total CO2 emissions for each equipment or event type (mt CO2) [98.236(i)(1)(ii)]0.0
Annual total CH4 emissions for each equipment or event type (mt CH4) [98.236(i)(1)(iii)]0.00
Equipment or event type [98.236(i)(1)] [98.236(i)(2)]Pig launchers and receivers
Total number of blowdowns for equipment or event type, N [98.236(i)(1)(i)]81
Annual total CO2 emissions for each equipment or event type (mt CO2) [98.236(i)(1)(ii)]0.0
Annual total CH4 emissions for each equipment or event type (mt CH4) [98.236(i)(1)(iii)]0.31
Equipment or event type [98.236(i)(1)] [98.236(i)(2)]Facility piping
Total number of blowdowns for equipment or event type, N [98.236(i)(1)(i)]1
Annual total CO2 emissions for each equipment or event type (mt CO2) [98.236(i)(1)(ii)]0.0
Annual total CH4 emissions for each equipment or event type (mt CH4) [98.236(i)(1)(iii)]0.01
Equipment or event type [98.236(i)(1)] [98.236(i)(2)]Compressors
Total number of blowdowns for equipment or event type, N [98.236(i)(1)(i)]65
Annual total CO2 emissions for each equipment or event type (mt CO2) [98.236(i)(1)(ii)]0.2
Annual total CH4 emissions for each equipment or event type (mt CH4) [98.236(i)(1)(iii)]2.19
Equipment or event type [98.236(i)(1)] [98.236(i)(2)]All other equipment with a physical volume greater than or equal 50 cubic feet
Total number of blowdowns for equipment or event type, N [98.236(i)(1)(i)]0
Annual total CO2 emissions for each equipment or event type (mt CO2) [98.236(i)(1)(ii)]0.0
Annual total CH4 emissions for each equipment or event type (mt CH4) [98.236(i)(1)(iii)]0.00
Equipment or event type [98.236(i)(1)] [98.236(i)(2)]Emergency shutdowns
Total number of blowdowns for equipment or event type, N [98.236(i)(1)(i)]0
Annual total CO2 emissions for each equipment or event type (mt CO2) [98.236(i)(1)(ii)]0.0
Annual total CH4 emissions for each equipment or event type (mt CH4) [98.236(i)(1)(iii)]0.00
Equipment or event type [98.236(i)(1)] [98.236(i)(2)]Scrubbers/strainers
Total number of blowdowns for equipment or event type, N [98.236(i)(1)(i)]0
Annual total CO2 emissions for each equipment or event type (mt CO2) [98.236(i)(1)(ii)]0.0
Annual total CH4 emissions for each equipment or event type (mt CH4) [98.236(i)(1)(iii)]0.00


FlareStacksDetails:
mt CO2482.4
mt CH45.02
mt N2O0.001
Did the facility have flare stacks subject to reporting under 98.232 [98.236(n)]?Yes
Were missing data procedures used for any parameters to calculate GHG emissions? [98.235]No


UniqueFlareStacksRowDetails:
Unique Name or ID Number for the Flare Stack [98.236(n)(1)]Flare (Plant Flare, 123/0595/024)
Does the flare stack have a continuous flow monitor on gas to the flare? [98.236(n)(2)]Yes
Does the flare stack have a continuous gas analyzer on gas to the flare? [98.236(n)(3)]No
Were CEMS used to measure CO2 emissions for the flare stack? [98.233(n)(8)] [98.236(n)(12)]No
Volume of gas sent to flare, Vs (standard cubic feet) [98.236(n)(4)]7004961.629
Flare combustion efficiency (decimal value) [98.236(n)(6)]0.95
Mole fraction of CH4 in flare feed gas, XCH4 [98.236(n)(7)]0.7464
Mole fraction of CO2 in flare feed gas, XCO2 [98.236(n)(8)]0.0241
Fraction of feed gas sent to un-lit flare, Zu [98.236(n)(5)]0.000
CO2 emissions (mt CO2) [98.236(n)(9)]482.4
CH4 Emissions (mt CH4) (Eq. W-19) [98.236(n)(10)]5.02
N2O Emissions (mt N2O) (Eq. W-40) [98.236(n)(11)]0.001
Unique Name or ID Number for the Flare Stack [98.236(n)(1)]Enclosed Combustor (Dehy Combustor, 123/0595/009)
Does the flare stack have a continuous flow monitor on gas to the flare? [98.236(n)(2)]No
Does the flare stack have a continuous gas analyzer on gas to the flare? [98.236(n)(3)]No
Were CEMS used to measure CO2 emissions for the flare stack? [98.233(n)(8)] [98.236(n)(12)]No
Volume of gas sent to flare, Vs (standard cubic feet) [98.236(n)(4)]11388000.000
Flare combustion efficiency (decimal value) [98.236(n)(6)]0.95
Mole fraction of CH4 in flare feed gas, XCH4 [98.236(n)(7)]0.0015
Mole fraction of CO2 in flare feed gas, XCO2 [98.236(n)(8)]0.0387
Fraction of feed gas sent to un-lit flare, Zu [98.236(n)(5)]0.000
CO2 emissions (mt CO2) [98.236(n)(9)]0.0
CH4 Emissions (mt CH4) (Eq. W-19) [98.236(n)(10)]0.00
N2O Emissions (mt N2O) (Eq. W-40) [98.236(n)(11)]0.000


CentrifugalCompressorsDetails:
mt CO20.0
mt CH40.00
Did the facility have any centrifugal compressors subject to reporting under 98.232 [98.236(o)]?No
Were missing data procedures used for any parameters to calculate GHG emissions? [98.235]No


ReciprocatingCompressorsDetails:
mt CO24.0
mt CH444.73
Did the facility have any reciprocating compressors subject to reporting under 98.232 [98.236(p)]?Yes
Were missing data procedures used for any parameters to calculate GHG emissions? [98.235]No


ReciprocatingCompressorsActivityDataRowDetails:
Unique name or ID for reciprocating compressor [98.236(p)(1)(i)]Compressor (Compressor for C-180, 123/0595/014) (GHG Only)
Total time in operating-mode (hours) [98.236(p)(1)(ii)]8083
Total time in standby-pressurized-mode (hours) [98.236(p)(1)(iii)]35.05
Total time in not-operating-depressurized-mode (hours) [98.236(p)(1)(iv)]665.95
Compressor measured in operating-mode? [98.236(p)(1)(v)]Yes
Compressor measured in standby-pressurized-mode? [98.236(p)(1)(vi)]No
Compressor measured in not-operating-depressurized-mode? [98.236(p)(1)(vii)]No
Compressor had blind flanges installed? [98.236(p)(1)(xii)]No
Power output of compressor driver (hp) [98.236(p)(1)(xiii)]1680
Compressor had scheduled depressurized shutdown during reporting year? [98.236(p)(1)(xiv)]Yes
Unique name or ID for reciprocating compressor [98.236(p)(1)(i)]Compressor (Compressor for C-175a, P-004, 123/0595/004) (GHG Only)
Total time in operating-mode (hours) [98.236(p)(1)(ii)]8329
Total time in standby-pressurized-mode (hours) [98.236(p)(1)(iii)]22.75
Total time in not-operating-depressurized-mode (hours) [98.236(p)(1)(iv)]432.25
Compressor measured in operating-mode? [98.236(p)(1)(v)]Yes
Compressor measured in standby-pressurized-mode? [98.236(p)(1)(vi)]No
Compressor measured in not-operating-depressurized-mode? [98.236(p)(1)(vii)]No
Compressor had blind flanges installed? [98.236(p)(1)(xii)]No
Power output of compressor driver (hp) [98.236(p)(1)(xiii)]1680
Compressor had scheduled depressurized shutdown during reporting year? [98.236(p)(1)(xiv)]Yes
Unique name or ID for reciprocating compressor [98.236(p)(1)(i)]Compressor (PLATTEVILLE PLANT #171) (GHG Only)
Total time in operating-mode (hours) [98.236(p)(1)(ii)]8495
Total time in standby-pressurized-mode (hours) [98.236(p)(1)(iii)]14.45
Total time in not-operating-depressurized-mode (hours) [98.236(p)(1)(iv)]274.55
Compressor measured in operating-mode? [98.236(p)(1)(v)]Yes
Compressor measured in standby-pressurized-mode? [98.236(p)(1)(vi)]No
Compressor measured in not-operating-depressurized-mode? [98.236(p)(1)(vii)]No
Compressor had blind flanges installed? [98.236(p)(1)(xii)]No
Power output of compressor driver (hp) [98.236(p)(1)(xiii)]1478
Compressor had scheduled depressurized shutdown during reporting year? [98.236(p)(1)(xiv)]Yes
Unique name or ID for reciprocating compressor [98.236(p)(1)(i)]Compressor (PLATTEVILLE PLANT #177) (GHG Only)
Total time in operating-mode (hours) [98.236(p)(1)(ii)]8050
Total time in standby-pressurized-mode (hours) [98.236(p)(1)(iii)]36.7
Total time in not-operating-depressurized-mode (hours) [98.236(p)(1)(iv)]697.3
Compressor measured in operating-mode? [98.236(p)(1)(v)]Yes
Compressor measured in standby-pressurized-mode? [98.236(p)(1)(vi)]No
Compressor measured in not-operating-depressurized-mode? [98.236(p)(1)(vii)]No
Compressor had blind flanges installed? [98.236(p)(1)(xii)]No
Power output of compressor driver (hp) [98.236(p)(1)(xiii)]1680
Compressor had scheduled depressurized shutdown during reporting year? [98.236(p)(1)(xiv)]Yes
Unique name or ID for reciprocating compressor [98.236(p)(1)(i)]Compressor (PLATTEVILLE PLANT #170) (GHG Only)
Total time in operating-mode (hours) [98.236(p)(1)(ii)]8514
Total time in standby-pressurized-mode (hours) [98.236(p)(1)(iii)]13.5
Total time in not-operating-depressurized-mode (hours) [98.236(p)(1)(iv)]256.5
Compressor measured in operating-mode? [98.236(p)(1)(v)]Yes
Compressor measured in standby-pressurized-mode? [98.236(p)(1)(vi)]No
Compressor measured in not-operating-depressurized-mode? [98.236(p)(1)(vii)]No
Compressor had blind flanges installed? [98.236(p)(1)(xii)]No
Power output of compressor driver (hp) [98.236(p)(1)(xiii)]1680
Compressor had scheduled depressurized shutdown during reporting year? [98.236(p)(1)(xiv)]Yes
Unique name or ID for reciprocating compressor [98.236(p)(1)(i)]Compressor (Compressor for C-169 a, P-002, 123/0595/002) (GHG Only)
Total time in operating-mode (hours) [98.236(p)(1)(ii)]8534
Total time in standby-pressurized-mode (hours) [98.236(p)(1)(iii)]12.5
Total time in not-operating-depressurized-mode (hours) [98.236(p)(1)(iv)]237.5
Compressor measured in operating-mode? [98.236(p)(1)(v)]Yes
Compressor measured in standby-pressurized-mode? [98.236(p)(1)(vi)]No
Compressor measured in not-operating-depressurized-mode? [98.236(p)(1)(vii)]No
Compressor had blind flanges installed? [98.236(p)(1)(xii)]No
Power output of compressor driver (hp) [98.236(p)(1)(xiii)]1680
Compressor had scheduled depressurized shutdown during reporting year? [98.236(p)(1)(xiv)]Yes
Unique name or ID for reciprocating compressor [98.236(p)(1)(i)]Compressor (Compressor for C-168a, P-001, 123/0595/001) (GHG Only)
Total time in operating-mode (hours) [98.236(p)(1)(ii)]8249
Total time in standby-pressurized-mode (hours) [98.236(p)(1)(iii)]26.75
Total time in not-operating-depressurized-mode (hours) [98.236(p)(1)(iv)]508.25
Compressor measured in operating-mode? [98.236(p)(1)(v)]Yes
Compressor measured in standby-pressurized-mode? [98.236(p)(1)(vi)]No
Compressor measured in not-operating-depressurized-mode? [98.236(p)(1)(vii)]No
Compressor had blind flanges installed? [98.236(p)(1)(xii)]No
Power output of compressor driver (hp) [98.236(p)(1)(xiii)]1680
Compressor had scheduled depressurized shutdown during reporting year? [98.236(p)(1)(xiv)]Yes


ReciprocatingCompressorSourceRowDetails:
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]Compressor (Compressor for C-180, 123/0595/014) (GHG Only)
Reciprocating compressor source [98.236(p)(2)(i)(B)]Blowdown valve
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]C180 BD
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]Compressor (Compressor for C-180, 123/0595/014) (GHG Only)
Reciprocating compressor source [98.236(p)(2)(i)(B)]Isolation valve
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]C180 ISO
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]Compressor (Compressor for C-180, 123/0595/014) (GHG Only)
Reciprocating compressor source [98.236(p)(2)(i)(B)]Rod packing
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]C180 RP
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]Compressor (Compressor for C-175a, P-004, 123/0595/004) (GHG Only)
Reciprocating compressor source [98.236(p)(2)(i)(B)]Blowdown valve
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]C175 BD
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]Compressor (Compressor for C-175a, P-004, 123/0595/004) (GHG Only)
Reciprocating compressor source [98.236(p)(2)(i)(B)]Isolation valve
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]C175 ISO
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]Compressor (Compressor for C-175a, P-004, 123/0595/004) (GHG Only)
Reciprocating compressor source [98.236(p)(2)(i)(B)]Rod packing
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]C175 RP
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]Compressor (PLATTEVILLE PLANT #171) (GHG Only)
Reciprocating compressor source [98.236(p)(2)(i)(B)]Blowdown valve
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]C171 BD
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]Compressor (PLATTEVILLE PLANT #171) (GHG Only)
Reciprocating compressor source [98.236(p)(2)(i)(B)]Isolation valve
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]C171 ISO
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]Compressor (PLATTEVILLE PLANT #171) (GHG Only)
Reciprocating compressor source [98.236(p)(2)(i)(B)]Rod packing
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]C171 RP
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]Compressor (PLATTEVILLE PLANT #177) (GHG Only)
Reciprocating compressor source [98.236(p)(2)(i)(B)]Blowdown valve
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]C177 BD
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]Compressor (PLATTEVILLE PLANT #177) (GHG Only)
Reciprocating compressor source [98.236(p)(2)(i)(B)]Isolation valve
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]C177 ISO
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]Compressor (PLATTEVILLE PLANT #177) (GHG Only)
Reciprocating compressor source [98.236(p)(2)(i)(B)]Rod packing
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]C177 RP
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]Compressor (PLATTEVILLE PLANT #170) (GHG Only)
Reciprocating compressor source [98.236(p)(2)(i)(B)]Blowdown valve
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]C170 BD
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]Compressor (PLATTEVILLE PLANT #170) (GHG Only)
Reciprocating compressor source [98.236(p)(2)(i)(B)]Isolation valve
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]C170 ISO
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]Compressor (PLATTEVILLE PLANT #170) (GHG Only)
Reciprocating compressor source [98.236(p)(2)(i)(B)]Rod packing
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]C170 RP
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]Compressor (Compressor for C-169 a, P-002, 123/0595/002) (GHG Only)
Reciprocating compressor source [98.236(p)(2)(i)(B)]Blowdown valve
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]C169 BD
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]Compressor (Compressor for C-169 a, P-002, 123/0595/002) (GHG Only)
Reciprocating compressor source [98.236(p)(2)(i)(B)]Isolation valve
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]C169 ISO
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]Compressor (Compressor for C-169 a, P-002, 123/0595/002) (GHG Only)
Reciprocating compressor source [98.236(p)(2)(i)(B)]Rod packing
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]C169 RP
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]Compressor (Compressor for C-168a, P-001, 123/0595/001) (GHG Only)
Reciprocating compressor source [98.236(p)(2)(i)(B)]Blowdown valve
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]C168 BD
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]Compressor (Compressor for C-168a, P-001, 123/0595/001) (GHG Only)
Reciprocating compressor source [98.236(p)(2)(i)(B)]Isolation valve
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]C168 ISO
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]Compressor (Compressor for C-168a, P-001, 123/0595/001) (GHG Only)
Reciprocating compressor source [98.236(p)(2)(i)(B)]Rod packing
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]C168 RP


ReciprocatingCompressorsLeakOrVentSampleDataRowDetails:
Unique Name or ID for leak or vent (Specify) [98.236(p)(2)(i)(C)] [98.236(p)(3)(i)(A)]C180 RP
Measurement date (mm/dd/yyyy) [98.236(p)(3)(i)(B)]2020-09-09
Measurement method [98.236(p)(3)(i)(C)]High volume sampler
Measured flow rate (standard cubic feet/hour) [98.236(p)(3)(i)(D)]4.7
Is the measurement location prior to or after commingling with non-compressor emission sources? [98.236(p)(3)(i)(F)]Not manifolded
Compressors in “Operating mode”Compressor (Compressor for C-180, 123/0595/014) (GHG Only)
Unique Name or ID for leak or vent (Specify) [98.236(p)(2)(i)(C)] [98.236(p)(3)(i)(A)]C175 RP
Measurement date (mm/dd/yyyy) [98.236(p)(3)(i)(B)]2020-09-09
Measurement method [98.236(p)(3)(i)(C)]Screening/Optical gas imaging
Measured flow rate (standard cubic feet/hour) [98.236(p)(3)(i)(D)]0
Is the measurement location prior to or after commingling with non-compressor emission sources? [98.236(p)(3)(i)(F)]Not manifolded
Compressors in “Operating mode”Compressor (Compressor for C-175a, P-004, 123/0595/004) (GHG Only)
Unique Name or ID for leak or vent (Specify) [98.236(p)(2)(i)(C)] [98.236(p)(3)(i)(A)]C171 RP
Measurement date (mm/dd/yyyy) [98.236(p)(3)(i)(B)]2020-09-09
Measurement method [98.236(p)(3)(i)(C)]Screening/Optical gas imaging
Measured flow rate (standard cubic feet/hour) [98.236(p)(3)(i)(D)]0
Is the measurement location prior to or after commingling with non-compressor emission sources? [98.236(p)(3)(i)(F)]Not manifolded
Compressors in “Operating mode”Compressor (PLATTEVILLE PLANT #171) (GHG Only)
Unique Name or ID for leak or vent (Specify) [98.236(p)(2)(i)(C)] [98.236(p)(3)(i)(A)]C177 RP
Measurement date (mm/dd/yyyy) [98.236(p)(3)(i)(B)]2020-09-09
Measurement method [98.236(p)(3)(i)(C)]High volume sampler
Measured flow rate (standard cubic feet/hour) [98.236(p)(3)(i)(D)]25.05
Is the measurement location prior to or after commingling with non-compressor emission sources? [98.236(p)(3)(i)(F)]Not manifolded
Compressors in “Operating mode”Compressor (PLATTEVILLE PLANT #177) (GHG Only)
Unique Name or ID for leak or vent (Specify) [98.236(p)(2)(i)(C)] [98.236(p)(3)(i)(A)]C170 RP
Measurement date (mm/dd/yyyy) [98.236(p)(3)(i)(B)]2020-09-09
Measurement method [98.236(p)(3)(i)(C)]High volume sampler
Measured flow rate (standard cubic feet/hour) [98.236(p)(3)(i)(D)]199.35
Is the measurement location prior to or after commingling with non-compressor emission sources? [98.236(p)(3)(i)(F)]Not manifolded
Compressors in “Operating mode”Compressor (PLATTEVILLE PLANT #170) (GHG Only)
Unique Name or ID for leak or vent (Specify) [98.236(p)(2)(i)(C)] [98.236(p)(3)(i)(A)]C169 RP
Measurement date (mm/dd/yyyy) [98.236(p)(3)(i)(B)]2020-09-09
Measurement method [98.236(p)(3)(i)(C)]High volume sampler
Measured flow rate (standard cubic feet/hour) [98.236(p)(3)(i)(D)]78.28
Is the measurement location prior to or after commingling with non-compressor emission sources? [98.236(p)(3)(i)(F)]Not manifolded
Compressors in “Operating mode”Compressor (Compressor for C-169 a, P-002, 123/0595/002) (GHG Only)
Unique Name or ID for leak or vent (Specify) [98.236(p)(2)(i)(C)] [98.236(p)(3)(i)(A)]C168 RP
Measurement date (mm/dd/yyyy) [98.236(p)(3)(i)(B)]2020-09-09
Measurement method [98.236(p)(3)(i)(C)]High volume sampler
Measured flow rate (standard cubic feet/hour) [98.236(p)(3)(i)(D)]62.62
Is the measurement location prior to or after commingling with non-compressor emission sources? [98.236(p)(3)(i)(F)]Not manifolded
Compressors in “Operating mode”Compressor (Compressor for C-168a, P-001, 123/0595/001) (GHG Only)


ReciprocatingCompressorsEmissionFactorsSampleDataRowDetails:
Compressor Mode [98.236(p)(3)(ii)(A)]Not-operating-depressurized
Compressor Source [98.236(p)(3)(ii)(A)]Isolation valve
Compressor mode-source combination reporter emission factor, EFs,m (standard cubic feet per hour) [98.236(p)(3)(ii)(B)]24.55
Total number of compressors measured in the compressor mode-source combination in current reporting year and preceding two reporting years, Countm [98.236(p)(3)(ii)(C)]224
Is the reporter emission factor facility-specific or based on all of the reporter's applicable facilities? [98.236(p)(3)(ii)(D)]All applicable facilities
Compressor Mode [98.236(p)(3)(ii)(A)]Operating
Compressor Source [98.236(p)(3)(ii)(A)]Blowdown valve
Compressor mode-source combination reporter emission factor, EFs,m (standard cubic feet per hour) [98.236(p)(3)(ii)(B)]2.06
Total number of compressors measured in the compressor mode-source combination in current reporting year and preceding two reporting years, Countm [98.236(p)(3)(ii)(C)]218
Is the reporter emission factor facility-specific or based on all of the reporter's applicable facilities? [98.236(p)(3)(ii)(D)]All applicable facilities
Compressor Mode [98.236(p)(3)(ii)(A)]Standby-pressurized
Compressor Source [98.236(p)(3)(ii)(A)]Blowdown valve
Compressor mode-source combination reporter emission factor, EFs,m (standard cubic feet per hour) [98.236(p)(3)(ii)(B)]1.29
Total number of compressors measured in the compressor mode-source combination in current reporting year and preceding two reporting years, Countm [98.236(p)(3)(ii)(C)]26
Is the reporter emission factor facility-specific or based on all of the reporter's applicable facilities? [98.236(p)(3)(ii)(D)]All applicable facilities
Compressor Mode [98.236(p)(3)(ii)(A)]Operating
Compressor Source [98.236(p)(3)(ii)(A)]Rod packing
Compressor mode-source combination reporter emission factor, EFs,m (standard cubic feet per hour) [98.236(p)(3)(ii)(B)]73.08
Total number of compressors measured in the compressor mode-source combination in current reporting year and preceding two reporting years, Countm [98.236(p)(3)(ii)(C)]458
Is the reporter emission factor facility-specific or based on all of the reporter's applicable facilities? [98.236(p)(3)(ii)(D)]All applicable facilities


ReciprocatingCompressorsLeakOrVentDataRowDetails:
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]C180 BD
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Vapor recovery
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]No
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)]0.0
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)]0.00
Percentage of time the device was operational when compressor source emissions were routed to device [98.236(p)(2)(ii)(E)]100
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]C180 ISO
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Vapor recovery
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]No
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)]0.0
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)]0.00
Percentage of time the device was operational when compressor source emissions were routed to device [98.236(p)(2)(ii)(E)]100
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]C180 RP
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]Yes
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)]0.0
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)]0.54
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]C175 BD
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Vapor recovery
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]No
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)]0.0
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)]0.00
Percentage of time the device was operational when compressor source emissions were routed to device [98.236(p)(2)(ii)(E)]100
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]C175 ISO
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Vapor recovery
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]No
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)]0.0
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)]0.00
Percentage of time the device was operational when compressor source emissions were routed to device [98.236(p)(2)(ii)(E)]100
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]C175 RP
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]Yes
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)]0.0
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)]0.00
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]C171 BD
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Vapor recovery
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]No
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)]0.0
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)]0.00
Percentage of time the device was operational when compressor source emissions were routed to device [98.236(p)(2)(ii)(E)]100
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]C171 ISO
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Vapor recovery
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]No
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)]0.0
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)]0.00
Percentage of time the device was operational when compressor source emissions were routed to device [98.236(p)(2)(ii)(E)]100
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]C171 RP
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]Yes
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)]0.0
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)]0.00
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]C177 BD
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Vapor recovery
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]No
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)]0.0
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)]0.00
Percentage of time the device was operational when compressor source emissions were routed to device [98.236(p)(2)(ii)(E)]100
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]C177 ISO
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Vapor recovery
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]No
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)]0.0
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)]0.00
Percentage of time the device was operational when compressor source emissions were routed to device [98.236(p)(2)(ii)(E)]100
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]C177 RP
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]Yes
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)]0.3
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)]2.89
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]C170 BD
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Vapor recovery
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]No
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)]0.0
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)]0.00
Percentage of time the device was operational when compressor source emissions were routed to device [98.236(p)(2)(ii)(E)]100
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]C170 ISO
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Vapor recovery
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]No
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)]0.0
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)]0.00
Percentage of time the device was operational when compressor source emissions were routed to device [98.236(p)(2)(ii)(E)]100
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]C170 RP
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]Yes
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)]2.2
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)]24.32
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]C169 BD
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Vapor recovery
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]No
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)]0.0
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)]0.00
Percentage of time the device was operational when compressor source emissions were routed to device [98.236(p)(2)(ii)(E)]100
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]C169 ISO
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Vapor recovery
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]No
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)]0.0
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)]0.00
Percentage of time the device was operational when compressor source emissions were routed to device [98.236(p)(2)(ii)(E)]100
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]C169 RP
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]Yes
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)]0.8
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)]9.57
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]C168 BD
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Vapor recovery
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]No
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)]0.0
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)]0.00
Percentage of time the device was operational when compressor source emissions were routed to device [98.236(p)(2)(ii)(E)]100
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]C168 ISO
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Vapor recovery
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]No
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)]0.0
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)]0.00
Percentage of time the device was operational when compressor source emissions were routed to device [98.236(p)(2)(ii)(E)]100
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]C168 RP
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]Yes
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)]0.7
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)]7.40


OtherEmissionsFromEquipmentLeaksDetails:
mt CO22.7
mt CH430.96
Did this facility use leak surveys to calculate emissions from equipment leaks in accordance with 98.232 [per 98.236(q)]?Yes
Did this facility use population counts to calculate emissions from equipment leaks in accordance with 98.232 [per 98.236(r)]?No
Did the facility elect to comply with 98.236(q) according to 98.233(q)(1)(iv) for any components at the facility [per 98.236(q)(1)(iv)]?No
Were missing data procedures used for any parameters to calculate GHG emissions? [98.235]No
Number of complete equipment leak surveys performed during the calendar year [98.236(q)(1)(i)]1
Optical gas imaging instrument as specified in §60.18 [98.234(a)(1)]No
Method 21 [98.234(a)(2)]Yes
Infrared laser beam illuminated instrument [98.234(a)(3)]No
Acoustic leak detection device [98.234(a)(5)]No
Optical gas imaging instrument as specified in §60.5397a [98.234(a)(6)]No
Method 21 as specified in §60.5397a [98.234(a)(7)]No


GasProcessingEmissionsFactorsRowDetails:
Component Type [98.236(q)(2)(i)]Non-Compressor Components, Gas Service - Connector
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)]6
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)]8784
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)]0.4
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)]4.31
Component Type [98.236(q)(2)(i)]Non-Compressor Components, Gas Service - Open-ended Line
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)]0
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)]0
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)]0.0
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)]0.00
Component Type [98.236(q)(2)(i)]Non-Compressor components, Gas Service - Pressure Relief Valve
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)]0
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)]0
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)]0.0
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)]0.00
Component Type [98.236(q)(2)(i)]Non-Compressor components, Gas Service - Meter
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)]0
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)]0
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)]0.0
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)]0.00
Component Type [98.236(q)(2)(i)]Compressor Components, Gas Service - Connector
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)]20
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)]8784
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)]1.2
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)]14.07
Component Type [98.236(q)(2)(i)]Compressor Components, Gas Service - Open-ended Line
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)]0
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)]0
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)]0.0
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)]0.00
Component Type [98.236(q)(2)(i)]Compressor Components, Gas Service - Pressure Relief Valve
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)]0
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)]0
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)]0.0
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)]0.00
Component Type [98.236(q)(2)(i)]Compressor Components, Gas Service - Meter
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)]0
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)]0
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)]0.0
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)]0.00
Component Type [98.236(q)(2)(i)]Non-Compressor Components, Gas Service - Valve
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)]4
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)]8784
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)]0.3
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)]3.23
Component Type [98.236(q)(2)(i)]Compressor Components, Gas Service - Valve
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)]5
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)]8784
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)]0.8
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)]9.34