Facility Name:North DeSoto Central Facility
Facility Identifier:
Facility Reporting Year:2020
Facility Location:
Address: 1679 Gravel Point Rd.
City: Frierson
State: LA
Postal Code: 71207

Facility Site Details:
CO2 equivalent emissions from facility subparts C-II, SS, and TT (metric tons):253,792.6
CO2 equivalent emissions from supplier subparts LL-QQ (metric tons):
Biogenic CO2 emissions from facility subparts C-II, SS, and TT (metric tons):0
Cogeneration Unit Emissions Indicator:N
GHG Report Start Date:2020-01-01
GHG Report End Date:2020-12-31
Description of Changes to Calculation Methodology:
Plant Code Indicator:N
Primary NAICS Code:211120
Second Primary NAICS Code:

Parent Company Details:
Parent Company Name:THE WILLIAMS COS INC
Address:One Williams Center, Tulsa,  OK 74172
Percent Ownership Interest:100

Subpart C: General Stationary Fuel Combustion

Gas Information Details

Gas NameCarbon Dioxide
Gas Quantity103,596.1 (Metric Tons)
Own Result?

Gas NameBiogenic Carbon dioxide
Gas Quantity0 (Metric Tons)
Own Result?

Gas NameMethane
Gas Quantity1.95 (Metric Tons)
Own Result?

Gas NameNitrous Oxide
Gas Quantity0.195 (Metric Tons)
Own Result?

Unit Details:
Unit Name : GP-1
Unit Type : OCS (Other combustion source)
Unit Description :
Other Unit Name :
Small Unit Aggregation Details:
Use Ivt Indicator: Y
Highest Maximum Rated Heat Input Capacity: 41.0
Cumulative Maximum Rated Heat Input Capacity: 257.61

Emission Details:
Annual CO2 mass emissions from sorbent: 0 (Metric Tons)
Annual Biogenic CO2 Emissions: 0 (metric tons)
Annual Fossil fuel based CO2 Emissions: 0 (metric tons)

Tier Fuel Details:
Fuel : Natural Gas (Weighted U.S. Average)
Tier Name : Tier 2 (Equation C-2a)
Tier Methodology Start Date : 2020-01-01
Tier Methodology End Date : 2020-12-31
Frequency of HHV determinations : Monthly

Tier 2 Monthly HHV Details :
JanuaryFebruaryMarchAprilMayJuneJulyAugustSeptemberOctoberNovemberDecember
N N N N N N N N N N N N

Fuel Emission Details :
Total CO2 emissionsTotal CH4 emissionsTotal N2O emissionsTotal CH4 emissions CO2eTotal N2O emissions CO2e
103596.1 (Metric Tons) 1.95 (Metric Tons) 0.195 (Metric Tons) 48.8 (Metric Tons) 58.2 (Metric Tons)



Subpart W: Petroleum and Natural Gas Systems

Gas Information Details

Gas NameCarbon Dioxide
Gas Quantity144,229 (Metric Tons)
Own Result?

Gas NameMethane
Gas Quantity234.39 (Metric Tons)
Own Result?

Gas NameNitrous Oxide
Gas Quantity0.003 (Metric Tons)
Own Result?


SubpartWSummaryDetails:
Industry Segment Number3
Industry Segment NameOnshore natural gas processing [98.230(a)(3)]
Total Reported CO2 Emissions (mt CO2)144229.0
Total CO2e Emissions (mt CO2e)150089.8
Total Reported CH4 Emissions (mt CH4)234.39
Total Reported N2O Emissions (mt N2O)0.003


SubpartWSourceReportingFormRowDetails:
Source Reporting FormOnshore Production [98.236(aa)(1)]
Required for Selected Industry SegmentNo
Source Reporting FormFacility Overview [98.236(aa)(2-11)]
Required for Selected Industry SegmentYes
Source Reporting FormNatural Gas Pneumatic Devices [98.236(b)]
Required for Selected Industry SegmentNo
Total Reported CO2 Emissions (mt CO2)0.0
Total Reported CH4 Emissions (mt CH4)0.00
Source Reporting FormNatural Gas Driven Pneumatic Pumps [98.236(c)]
Required for Selected Industry SegmentNo
Total Reported CO2 Emissions (mt CO2)0.0
Total Reported CH4 Emissions (mt CH4)0.00
Source Reporting FormAcid Gas Removal Units [98.236(d)]
Required for Selected Industry SegmentYes
Total Reported CO2 Emissions (mt CO2)142772.2
Source Reporting FormDehydrators [98.236(e)]
Required for Selected Industry SegmentYes
Total Reported CO2 Emissions (mt CO2)1004.7
Total Reported CH4 Emissions (mt CH4)19.04
Total Reported N2O Emissions (mt N2O)0.002
Source Reporting FormWell Venting for Liquids Unloading [98.236(f)]
Required for Selected Industry SegmentNo
Total Reported CO2 Emissions (mt CO2)0.0
Total Reported CH4 Emissions (mt CH4)0.00
Source Reporting FormCompletions and Workovers with Hydraulic Fracturing [98.236(g)]
Required for Selected Industry SegmentNo
Total Reported CO2 Emissions (mt CO2)0.0
Total Reported CH4 Emissions (mt CH4)0.00
Total Reported N2O Emissions (mt N2O)0.000
Source Reporting FormCompletions and Workovers without Hydraulic Fracturing [98.236(h)]
Required for Selected Industry SegmentNo
Total Reported CO2 Emissions (mt CO2)0.0
Total Reported CH4 Emissions (mt CH4)0.00
Total Reported N2O Emissions (mt N2O)0.000
Source Reporting FormBlowdown Vent Stacks [98.236(i)]
Required for Selected Industry SegmentYes
Total Reported CO2 Emissions (mt CO2)8.8
Total Reported CH4 Emissions (mt CH4)86.95
Source Reporting FormAtmospheric Storage Tanks [98.236(j)]
Required for Selected Industry SegmentNo
Total Reported CO2 Emissions (mt CO2)0.0
Total Reported CH4 Emissions (mt CH4)0.00
Total Reported N2O Emissions (mt N2O)0.000
Source Reporting FormTransmission Storage Tanks [98.236(k)]
Required for Selected Industry SegmentNo
Total Reported CO2 Emissions (mt CO2)0.0
Total Reported CH4 Emissions (mt CH4)0.00
Total Reported N2O Emissions (mt N2O)0.000
Source Reporting FormWell Testing [98.236(l)]
Required for Selected Industry SegmentNo
Total Reported CO2 Emissions (mt CO2)0.0
Total Reported CH4 Emissions (mt CH4)0.00
Total Reported N2O Emissions (mt N2O)0.000
Source Reporting FormAssociated Gas Venting and Flaring [98.236(m)]
Required for Selected Industry SegmentNo
Total Reported CO2 Emissions (mt CO2)0.0
Total Reported CH4 Emissions (mt CH4)0.00
Total Reported N2O Emissions (mt N2O)0.000
Source Reporting FormFlare Stacks [98.236(n)]
Required for Selected Industry SegmentYes
Total Reported CO2 Emissions (mt CO2)436.5
Total Reported CH4 Emissions (mt CH4)3.18
Total Reported N2O Emissions (mt N2O)0.001
Source Reporting FormCentrifugal Compressors [98.236(o)]
Required for Selected Industry SegmentYes
Total Reported CO2 Emissions (mt CO2)0.0
Total Reported CH4 Emissions (mt CH4)0.00
Source Reporting FormReciprocating Compressors [98.236(p)]
Required for Selected Industry SegmentYes
Total Reported CO2 Emissions (mt CO2)6.4
Total Reported CH4 Emissions (mt CH4)119.99
Source Reporting FormEquipment Leaks Surveys and Population Counts [98.236(q,r)]
Required for Selected Industry SegmentYes
Total Reported CO2 Emissions (mt CO2)0.5
Total Reported CH4 Emissions (mt CH4)5.22
Source Reporting FormOffshore Petroleum and Natural Gas Production [98.236(s)]
Required for Selected Industry SegmentNo
Total Reported CO2 Emissions (mt CO2)0.0
Total Reported CH4 Emissions (mt CH4)0.00
Total Reported N2O Emissions (mt N2O)0.000
Source Reporting FormEnhanced Oil Recovery Injection Pumps [98.236(w)]
Required for Selected Industry SegmentNo
Total Reported CO2 Emissions (mt CO2)0.0
Source Reporting FormEnhanced Oil Recovery Hydrocarbon Liquids [98.236(x)]
Required for Selected Industry SegmentNo
Total Reported CO2 Emissions (mt CO2)0.0
Source Reporting FormCombustion Equipment at Onshore Petroleum and Natural Gas Production Facilities, Onshore Petroleum and Natural Gas Gathering and Boosting Facilities, and Natural gas Distribution Facilities [98.236(z)]
Required for Selected Industry SegmentNo
Total Reported CO2 Emissions (mt CO2)0.0
Total Reported CH4 Emissions (mt CH4)0.00
Total Reported N2O Emissions (mt N2O)0.000


FacilityOverviewDetails:


FacilityOverviewNaturalGasProcessingRowDetails:
Average mole fraction of CH4 in natural gas received [98.236(aa)(3)(v)]0.9624
Average mole fraction of CO2 in natural gas received [98.236(aa)(3)(vi)]0.03544
Does the facility fractionate NGLs? [98.236(aa)(3)(vii)]No


AcidGasRemovalUnitsDetails:
mt CO2142772.2
Did the Facility have any acid gas removal units that vent directly to the atmosphere, to a flare or engine, or to a sulfur recovery plant subject to reporting under 98.232 [98.236(d)]?Yes
Were missing data procedures used for any parameters to calculate GHG emissions? [98.235]No


AcidGasInfoRowDetails:
Unit ID or Name [98.236(d)(1)(i)]Amine 1A
Total feed rate entering the acid gas removal unit for the year (million cubic feet) [98.236(d)(1)(ii)]9884.362
Calculation Method Used (Select from list) [98.236(d)(1)(iii)]Calculation Methodology 4 [98.233(d)(4)]
Are any CO2 emissions from the acid gas removal unit recovered and transferred outside the facility? (Yes / No) [98.236(d)(1)(iv)]No
Total CO2 Emissions (mt CO2) [98.236(d)(1)(v)]18807.77
Unit ID or Name [98.236(d)(1)(i)]Amine 1B
Total feed rate entering the acid gas removal unit for the year (million cubic feet) [98.236(d)(1)(ii)]18516.412
Calculation Method Used (Select from list) [98.236(d)(1)(iii)]Calculation Methodology 4 [98.233(d)(4)]
Are any CO2 emissions from the acid gas removal unit recovered and transferred outside the facility? (Yes / No) [98.236(d)(1)(iv)]No
Total CO2 Emissions (mt CO2) [98.236(d)(1)(v)]35180.59
Unit ID or Name [98.236(d)(1)(i)]Amine 2A
Total feed rate entering the acid gas removal unit for the year (million cubic feet) [98.236(d)(1)(ii)]23360
Calculation Method Used (Select from list) [98.236(d)(1)(iii)]Calculation Methodology 4 [98.233(d)(4)]
Are any CO2 emissions from the acid gas removal unit recovered and transferred outside the facility? (Yes / No) [98.236(d)(1)(iv)]No
Total CO2 Emissions (mt CO2) [98.236(d)(1)(v)]44391.9
Unit ID or Name [98.236(d)(1)(i)]Amine 2B
Total feed rate entering the acid gas removal unit for the year (million cubic feet) [98.236(d)(1)(ii)]23159.25
Calculation Method Used (Select from list) [98.236(d)(1)(iii)]Calculation Methodology 4 [98.233(d)(4)]
Are any CO2 emissions from the acid gas removal unit recovered and transferred outside the facility? (Yes / No) [98.236(d)(1)(iv)]No
Total CO2 Emissions (mt CO2) [98.236(d)(1)(v)]44391.9


AcidGasCalcMethod4EmissionsRowDetails:
Unit ID or Name [98.236(d)(1)(i)]Amine 1A
Name of simulation software package used [98.236(d)(2)(iii)(A)]AmineCalc
Natural gas feed temperature (°F) [98.236(d)(2)(iii)(B)]74
Natural gas feed pressure (psi) [98.236(d)(2)(iii)(C)]1008
Natural gas feed flow rate (standard cubic feet per minute) [98.236(d)(2)(iii)(D)]25465.9710414
Acid gas content of feed natural gas (mole percent) [98.236(d)(2)(iii)(E)]3.62
Acid gas content of outlet natural gas (mole percent) [98.236(d)(2)(iii)(F)]0.007
Unit operating hours (excluding downtime for maintenance or standby) [98.236(d)(2)(iii)(G)]6469
Exit temperature of the natural gas (°F) [98.236(d)(2)(iii)(H)]114
Solvent pressure (psi) [98.236(d)(2)(iii)(I)]1008
Solvent temperature (°F) [98.236(d)(2)(iii)(J)]114
Solvent circulation rate (gallons per minute) [98.236(d)(2)(iii)(K)]276
Solvent weight (pounds per gallon) [98.236(d)(2)(iii)(L)]8.6926819
Unit ID or Name [98.236(d)(1)(i)]Amine 1B
Name of simulation software package used [98.236(d)(2)(iii)(A)]AmineCalc
Natural gas feed temperature (°F) [98.236(d)(2)(iii)(B)]74
Natural gas feed pressure (psi) [98.236(d)(2)(iii)(C)]1008
Natural gas feed flow rate (standard cubic feet per minute) [98.236(d)(2)(iii)(D)]35631.7823192
Acid gas content of feed natural gas (mole percent) [98.236(d)(2)(iii)(E)]3.6173
Acid gas content of outlet natural gas (mole percent) [98.236(d)(2)(iii)(F)]0.005
Unit operating hours (excluding downtime for maintenance or standby) [98.236(d)(2)(iii)(G)]8784
Exit temperature of the natural gas (°F) [98.236(d)(2)(iii)(H)]114
Solvent pressure (psi) [98.236(d)(2)(iii)(I)]1008
Solvent temperature (°F) [98.236(d)(2)(iii)(J)]114
Solvent circulation rate (gallons per minute) [98.236(d)(2)(iii)(K)]334
Solvent weight (pounds per gallon) [98.236(d)(2)(iii)(L)]8.6926819
Unit ID or Name [98.236(d)(1)(i)]Amine 2A
Name of simulation software package used [98.236(d)(2)(iii)(A)]AmineCalc
Natural gas feed temperature (°F) [98.236(d)(2)(iii)(B)]74
Natural gas feed pressure (psi) [98.236(d)(2)(iii)(C)]1003
Natural gas feed flow rate (standard cubic feet per minute) [98.236(d)(2)(iii)(D)]44323.0115361
Acid gas content of feed natural gas (mole percent) [98.236(d)(2)(iii)(E)]3.6173
Acid gas content of outlet natural gas (mole percent) [98.236(d)(2)(iii)(F)]0.005
Unit operating hours (excluding downtime for maintenance or standby) [98.236(d)(2)(iii)(G)]8784
Exit temperature of the natural gas (°F) [98.236(d)(2)(iii)(H)]114
Solvent pressure (psi) [98.236(d)(2)(iii)(I)]1003
Solvent temperature (°F) [98.236(d)(2)(iii)(J)]114
Solvent circulation rate (gallons per minute) [98.236(d)(2)(iii)(K)]380
Solvent weight (pounds per gallon) [98.236(d)(2)(iii)(L)]8.6926819
Unit ID or Name [98.236(d)(1)(i)]Amine 2B
Name of simulation software package used [98.236(d)(2)(iii)(A)]AmineCalc
Natural gas feed temperature (°F) [98.236(d)(2)(iii)(B)]74
Natural gas feed pressure (psi) [98.236(d)(2)(iii)(C)]1003
Natural gas feed flow rate (standard cubic feet per minute) [98.236(d)(2)(iii)(D)]43942.1106557
Acid gas content of feed natural gas (mole percent) [98.236(d)(2)(iii)(E)]3.6173
Acid gas content of outlet natural gas (mole percent) [98.236(d)(2)(iii)(F)]0.005
Unit operating hours (excluding downtime for maintenance or standby) [98.236(d)(2)(iii)(G)]8784
Exit temperature of the natural gas (°F) [98.236(d)(2)(iii)(H)]114
Solvent pressure (psi) [98.236(d)(2)(iii)(I)]1003
Solvent temperature (°F) [98.236(d)(2)(iii)(J)]114
Solvent circulation rate (gallons per minute) [98.236(d)(2)(iii)(K)]379
Solvent weight (pounds per gallon) [98.236(d)(2)(iii)(L)]8.6926819


DehydratorsDetails:
mt CO21004.7
mt CH419.04
mt N2O0.002
Did the facility have any glycol dehydrators with annual average daily natural gas throughputs greater than or equal to 0.4MMscfd subject to reporting under 98.232 [98.236(e)]?Yes
Did the facility have any glycol dehydrators with annual average daily natural gas throughputs less than 0.4MMscfd subject to reporting under 98.232 [98.236(e)]?No
Did the facility have any desiccant dehydrators subject to reporting under 98.232 [98.236(e)]?No
Were missing data procedures used for any parameters to calculate GHG emissions? [98.235]No


SmallGlycolDehydrators:
Emissions vented to flare or regenerator firebox/fire tubes
Emissions that were not vented to a flare or regenerator firebox/fire tubes


DessicantDehydrators:
Emissions vented to flare or regenerator firebox/fire tubes
Emissions that were not vented to a flare or regenerator firebox/fire tubes


GlycolDehydratorsMoreThanSpecifiedValueRowDetails:
Unit ID or Name [98.236(e)(1)(i)]Haynesville - North Desoto -- NG Plant --- DE SOTO, LA (31) 230 - Dehy D Train 2 (Central Processing Worksheet)
Sub-Basin ID [98.236(e)(1)(xviii]Not G&B
Glycol dehydrator feed natural gas flow rate determined by engineering estimate based on best available data (MMscfd) [98.236(e)(1)(ii)]63.293
Dehydrator feed natural gas water content (pounds per MMscf) [98.236(e)(1)(iii)]28.69
Dehydrator outlet natural gas water content (pounds per MMscf) [98.236(e)(1)(iv)]1.29
Glycol dehydrator absorbent circulation pump type [98.236(e)(1)(v)]Electric/Pneumatic
Dehydrator absorbent circulation rate (gallons per minute) [98.236(e)(1)(vi)]8
Report type of absorbent used [98.236(e)(1)(vii)]Triethylene glycol (TEG)
Report whether stripper gas is used in glycol dehydrator [98.236(e)(1)(viii)]No
Report whether a flash tank separator is used in glycol dehydrator [98.236(e)(1)(ix)]Yes
Total time the glycol dehydrator is operating (hours) [98.236(e)(1)(x)]7201
Temperature of the wet natural gas (°F) [98.236(e)(1)(xi)]76
Pressure of the wet natural gas (psig) [98.236(e)(1)(xii)]967
Concentration of CO2 in wet natural gas (mole fraction) [98.236(e)(1)(xiv)]0
Concentration of CH4 in wet natural gas (mole fraction) [98.236(e)(1)(xiii)]0.997
Were any dehydrator emissions vented to a vapor recovery device? [98.236(e)(1)(xv)]No
Were any dehydrator emissions vented to a flare or regenerator firebox/fire tubes? [98.236(e)(1)(xvi)]Yes
CO2 Emissions from Flares or Regenerators (mt CO2) [98.236(e)(1)(xvi)(A)]124.7548647
CH4 Emissions from Flares or Regenerators (mt CH4) [98.236(e)(1)(xvi)(B)]2.3647131
N2O Emissions from Flares or Regenerators (mt N2O) [98.236(e)(1)(xvi)(C)]0.0002915
Were any dehydrator emissions vented to the atmosphere without being routed to a flare or regenerator firebox/fire tubes? [98.236(e)(1)(xvii)]No
Unit ID or Name [98.236(e)(1)(i)]Haynesville - North Desoto -- NG Plant --- DE SOTO, LA (31) 230 - DehyA - Train1 (Central Processing Worksheet)
Sub-Basin ID [98.236(e)(1)(xviii]Not G&B
Glycol dehydrator feed natural gas flow rate determined by engineering estimate based on best available data (MMscfd) [98.236(e)(1)(ii)]47.496
Dehydrator feed natural gas water content (pounds per MMscf) [98.236(e)(1)(iii)]28.69
Dehydrator outlet natural gas water content (pounds per MMscf) [98.236(e)(1)(iv)]1.17
Glycol dehydrator absorbent circulation pump type [98.236(e)(1)(v)]Electric
Dehydrator absorbent circulation rate (gallons per minute) [98.236(e)(1)(vi)]8
Report type of absorbent used [98.236(e)(1)(vii)]Triethylene glycol (TEG)
Report whether stripper gas is used in glycol dehydrator [98.236(e)(1)(viii)]No
Report whether a flash tank separator is used in glycol dehydrator [98.236(e)(1)(ix)]Yes
Total time the glycol dehydrator is operating (hours) [98.236(e)(1)(x)]6345
Temperature of the wet natural gas (°F) [98.236(e)(1)(xi)]76
Pressure of the wet natural gas (psig) [98.236(e)(1)(xii)]967
Concentration of CO2 in wet natural gas (mole fraction) [98.236(e)(1)(xiv)]0
Concentration of CH4 in wet natural gas (mole fraction) [98.236(e)(1)(xiii)]0.997
Were any dehydrator emissions vented to a vapor recovery device? [98.236(e)(1)(xv)]No
Were any dehydrator emissions vented to a flare or regenerator firebox/fire tubes? [98.236(e)(1)(xvi)]Yes
CO2 Emissions from Flares or Regenerators (mt CO2) [98.236(e)(1)(xvi)(A)]129.6833473
CH4 Emissions from Flares or Regenerators (mt CH4) [98.236(e)(1)(xvi)(B)]2.4550176
N2O Emissions from Flares or Regenerators (mt N2O) [98.236(e)(1)(xvi)(C)]0.0003024
Were any dehydrator emissions vented to the atmosphere without being routed to a flare or regenerator firebox/fire tubes? [98.236(e)(1)(xvii)]No
Unit ID or Name [98.236(e)(1)(i)]Haynesville - North Desoto -- NG Plant --- DE SOTO, LA (31) 230 - DehyA - Train2 (Central Processing Worksheet)
Sub-Basin ID [98.236(e)(1)(xviii]Not G&B
Glycol dehydrator feed natural gas flow rate determined by engineering estimate based on best available data (MMscfd) [98.236(e)(1)(ii)]65.299
Dehydrator feed natural gas water content (pounds per MMscf) [98.236(e)(1)(iii)]28.69
Dehydrator outlet natural gas water content (pounds per MMscf) [98.236(e)(1)(iv)]1.25
Glycol dehydrator absorbent circulation pump type [98.236(e)(1)(v)]Electric
Dehydrator absorbent circulation rate (gallons per minute) [98.236(e)(1)(vi)]9
Report type of absorbent used [98.236(e)(1)(vii)]Triethylene glycol (TEG)
Report whether stripper gas is used in glycol dehydrator [98.236(e)(1)(viii)]No
Report whether a flash tank separator is used in glycol dehydrator [98.236(e)(1)(ix)]Yes
Total time the glycol dehydrator is operating (hours) [98.236(e)(1)(x)]7337
Temperature of the wet natural gas (°F) [98.236(e)(1)(xi)]76
Pressure of the wet natural gas (psig) [98.236(e)(1)(xii)]967
Concentration of CO2 in wet natural gas (mole fraction) [98.236(e)(1)(xiv)]0
Concentration of CH4 in wet natural gas (mole fraction) [98.236(e)(1)(xiii)]0.997
Were any dehydrator emissions vented to a vapor recovery device? [98.236(e)(1)(xv)]No
Were any dehydrator emissions vented to a flare or regenerator firebox/fire tubes? [98.236(e)(1)(xvi)]Yes
CO2 Emissions from Flares or Regenerators (mt CO2) [98.236(e)(1)(xvi)(A)]141.4491483
CH4 Emissions from Flares or Regenerators (mt CH4) [98.236(e)(1)(xvi)(B)]2.6822203
N2O Emissions from Flares or Regenerators (mt N2O) [98.236(e)(1)(xvi)(C)]0.0003307
Were any dehydrator emissions vented to the atmosphere without being routed to a flare or regenerator firebox/fire tubes? [98.236(e)(1)(xvii)]No
Unit ID or Name [98.236(e)(1)(i)]Haynesville - North Desoto -- NG Plant --- DE SOTO, LA (31) 230 - DehyB - Train1 (Central Processing Worksheet)
Sub-Basin ID [98.236(e)(1)(xviii]Not G&B
Glycol dehydrator feed natural gas flow rate determined by engineering estimate based on best available data (MMscfd) [98.236(e)(1)(ii)]56.49
Dehydrator feed natural gas water content (pounds per MMscf) [98.236(e)(1)(iii)]28.69
Dehydrator outlet natural gas water content (pounds per MMscf) [98.236(e)(1)(iv)]1.24
Glycol dehydrator absorbent circulation pump type [98.236(e)(1)(v)]Electric
Dehydrator absorbent circulation rate (gallons per minute) [98.236(e)(1)(vi)]8
Report type of absorbent used [98.236(e)(1)(vii)]Triethylene glycol (TEG)
Report whether stripper gas is used in glycol dehydrator [98.236(e)(1)(viii)]No
Report whether a flash tank separator is used in glycol dehydrator [98.236(e)(1)(ix)]Yes
Total time the glycol dehydrator is operating (hours) [98.236(e)(1)(x)]7292
Temperature of the wet natural gas (°F) [98.236(e)(1)(xi)]76
Pressure of the wet natural gas (psig) [98.236(e)(1)(xii)]967
Concentration of CO2 in wet natural gas (mole fraction) [98.236(e)(1)(xiv)]0
Concentration of CH4 in wet natural gas (mole fraction) [98.236(e)(1)(xiii)]0.997
Were any dehydrator emissions vented to a vapor recovery device? [98.236(e)(1)(xv)]No
Were any dehydrator emissions vented to a flare or regenerator firebox/fire tubes? [98.236(e)(1)(xvi)]Yes
CO2 Emissions from Flares or Regenerators (mt CO2) [98.236(e)(1)(xvi)(A)]125.2226211
CH4 Emissions from Flares or Regenerators (mt CH4) [98.236(e)(1)(xvi)(B)]2.3745295
N2O Emissions from Flares or Regenerators (mt N2O) [98.236(e)(1)(xvi)(C)]0.0002928
Were any dehydrator emissions vented to the atmosphere without being routed to a flare or regenerator firebox/fire tubes? [98.236(e)(1)(xvii)]No
Unit ID or Name [98.236(e)(1)(i)]Haynesville - North Desoto -- NG Plant --- DE SOTO, LA (31) 230 - DehyB - Train2 (Central Processing Worksheet)
Sub-Basin ID [98.236(e)(1)(xviii]Not G&B
Glycol dehydrator feed natural gas flow rate determined by engineering estimate based on best available data (MMscfd) [98.236(e)(1)(ii)]63.471
Dehydrator feed natural gas water content (pounds per MMscf) [98.236(e)(1)(iii)]28.69
Dehydrator outlet natural gas water content (pounds per MMscf) [98.236(e)(1)(iv)]1.29
Glycol dehydrator absorbent circulation pump type [98.236(e)(1)(v)]Electric/Pneumatic
Dehydrator absorbent circulation rate (gallons per minute) [98.236(e)(1)(vi)]8
Report type of absorbent used [98.236(e)(1)(vii)]Triethylene glycol (TEG)
Report whether stripper gas is used in glycol dehydrator [98.236(e)(1)(viii)]No
Report whether a flash tank separator is used in glycol dehydrator [98.236(e)(1)(ix)]Yes
Total time the glycol dehydrator is operating (hours) [98.236(e)(1)(x)]6396
Temperature of the wet natural gas (°F) [98.236(e)(1)(xi)]76
Pressure of the wet natural gas (psig) [98.236(e)(1)(xii)]967
Concentration of CO2 in wet natural gas (mole fraction) [98.236(e)(1)(xiv)]0
Concentration of CH4 in wet natural gas (mole fraction) [98.236(e)(1)(xiii)]0.997
Were any dehydrator emissions vented to a vapor recovery device? [98.236(e)(1)(xv)]No
Were any dehydrator emissions vented to a flare or regenerator firebox/fire tubes? [98.236(e)(1)(xvi)]Yes
CO2 Emissions from Flares or Regenerators (mt CO2) [98.236(e)(1)(xvi)(A)]109.8514436
CH4 Emissions from Flares or Regenerators (mt CH4) [98.236(e)(1)(xvi)(B)]2.076219
N2O Emissions from Flares or Regenerators (mt N2O) [98.236(e)(1)(xvi)(C)]0.000256
Were any dehydrator emissions vented to the atmosphere without being routed to a flare or regenerator firebox/fire tubes? [98.236(e)(1)(xvii)]No
Unit ID or Name [98.236(e)(1)(i)]Haynesville - North Desoto -- NG Plant --- DE SOTO, LA (31) 230 - DehyC - Train1 (Central Processing Worksheet)
Sub-Basin ID [98.236(e)(1)(xviii]Not G&B
Glycol dehydrator feed natural gas flow rate determined by engineering estimate based on best available data (MMscfd) [98.236(e)(1)(ii)]67.22
Dehydrator feed natural gas water content (pounds per MMscf) [98.236(e)(1)(iii)]28.69
Dehydrator outlet natural gas water content (pounds per MMscf) [98.236(e)(1)(iv)]1.27
Glycol dehydrator absorbent circulation pump type [98.236(e)(1)(v)]Electric
Dehydrator absorbent circulation rate (gallons per minute) [98.236(e)(1)(vi)]9
Report type of absorbent used [98.236(e)(1)(vii)]Triethylene glycol (TEG)
Report whether stripper gas is used in glycol dehydrator [98.236(e)(1)(viii)]No
Report whether a flash tank separator is used in glycol dehydrator [98.236(e)(1)(ix)]Yes
Total time the glycol dehydrator is operating (hours) [98.236(e)(1)(x)]6713.5
Temperature of the wet natural gas (°F) [98.236(e)(1)(xi)]76
Pressure of the wet natural gas (psig) [98.236(e)(1)(xii)]967
Concentration of CO2 in wet natural gas (mole fraction) [98.236(e)(1)(xiv)]0
Concentration of CH4 in wet natural gas (mole fraction) [98.236(e)(1)(xiii)]0.997
Were any dehydrator emissions vented to a vapor recovery device? [98.236(e)(1)(xv)]No
Were any dehydrator emissions vented to a flare or regenerator firebox/fire tubes? [98.236(e)(1)(xvi)]Yes
CO2 Emissions from Flares or Regenerators (mt CO2) [98.236(e)(1)(xvi)(A)]129.4291368
CH4 Emissions from Flares or Regenerators (mt CH4) [98.236(e)(1)(xvi)(B)]2.4544599
N2O Emissions from Flares or Regenerators (mt N2O) [98.236(e)(1)(xvi)(C)]0.0003026
Were any dehydrator emissions vented to the atmosphere without being routed to a flare or regenerator firebox/fire tubes? [98.236(e)(1)(xvii)]No
Unit ID or Name [98.236(e)(1)(i)]Haynesville - North Desoto -- NG Plant --- DE SOTO, LA (31) 230 - DehyC - Train2 (Central Processing Worksheet)
Sub-Basin ID [98.236(e)(1)(xviii]Not G&B
Glycol dehydrator feed natural gas flow rate determined by engineering estimate based on best available data (MMscfd) [98.236(e)(1)(ii)]62.38
Dehydrator feed natural gas water content (pounds per MMscf) [98.236(e)(1)(iii)]28.69
Dehydrator outlet natural gas water content (pounds per MMscf) [98.236(e)(1)(iv)]1.29
Glycol dehydrator absorbent circulation pump type [98.236(e)(1)(v)]Electric
Dehydrator absorbent circulation rate (gallons per minute) [98.236(e)(1)(vi)]8
Report type of absorbent used [98.236(e)(1)(vii)]Triethylene glycol (TEG)
Report whether stripper gas is used in glycol dehydrator [98.236(e)(1)(viii)]No
Report whether a flash tank separator is used in glycol dehydrator [98.236(e)(1)(ix)]Yes
Total time the glycol dehydrator is operating (hours) [98.236(e)(1)(x)]6914
Temperature of the wet natural gas (°F) [98.236(e)(1)(xi)]76
Pressure of the wet natural gas (psig) [98.236(e)(1)(xii)]967
Concentration of CO2 in wet natural gas (mole fraction) [98.236(e)(1)(xiv)]0
Concentration of CH4 in wet natural gas (mole fraction) [98.236(e)(1)(xiii)]0.997
Were any dehydrator emissions vented to a vapor recovery device? [98.236(e)(1)(xv)]No
Were any dehydrator emissions vented to a flare or regenerator firebox/fire tubes? [98.236(e)(1)(xvi)]Yes
CO2 Emissions from Flares or Regenerators (mt CO2) [98.236(e)(1)(xvi)(A)]118.3334487
CH4 Emissions from Flares or Regenerators (mt CH4) [98.236(e)(1)(xvi)(B)]2.2440481
N2O Emissions from Flares or Regenerators (mt N2O) [98.236(e)(1)(xvi)(C)]0.0002767
Were any dehydrator emissions vented to the atmosphere without being routed to a flare or regenerator firebox/fire tubes? [98.236(e)(1)(xvii)]No
Unit ID or Name [98.236(e)(1)(i)]Haynesville - North Desoto -- NG Plant --- DE SOTO, LA (31) 230 - DehyD - Train1 (Central Processing Worksheet)
Sub-Basin ID [98.236(e)(1)(xviii]Not G&B
Glycol dehydrator feed natural gas flow rate determined by engineering estimate based on best available data (MMscfd) [98.236(e)(1)(ii)]65.85
Dehydrator feed natural gas water content (pounds per MMscf) [98.236(e)(1)(iii)]28.69
Dehydrator outlet natural gas water content (pounds per MMscf) [98.236(e)(1)(iv)]1.26
Glycol dehydrator absorbent circulation pump type [98.236(e)(1)(v)]Electric
Dehydrator absorbent circulation rate (gallons per minute) [98.236(e)(1)(vi)]9
Report type of absorbent used [98.236(e)(1)(vii)]Triethylene glycol (TEG)
Report whether stripper gas is used in glycol dehydrator [98.236(e)(1)(viii)]No
Report whether a flash tank separator is used in glycol dehydrator [98.236(e)(1)(ix)]Yes
Total time the glycol dehydrator is operating (hours) [98.236(e)(1)(x)]6536
Temperature of the wet natural gas (°F) [98.236(e)(1)(xi)]76
Pressure of the wet natural gas (psig) [98.236(e)(1)(xii)]967
Concentration of CO2 in wet natural gas (mole fraction) [98.236(e)(1)(xiv)]0
Concentration of CH4 in wet natural gas (mole fraction) [98.236(e)(1)(xiii)]0.997
Were any dehydrator emissions vented to a vapor recovery device? [98.236(e)(1)(xv)]No
Were any dehydrator emissions vented to a flare or regenerator firebox/fire tubes? [98.236(e)(1)(xvi)]Yes
CO2 Emissions from Flares or Regenerators (mt CO2) [98.236(e)(1)(xvi)(A)]126.0100406
CH4 Emissions from Flares or Regenerators (mt CH4) [98.236(e)(1)(xvi)(B)]2.3895658
N2O Emissions from Flares or Regenerators (mt N2O) [98.236(e)(1)(xvi)(C)]0.0002946
Were any dehydrator emissions vented to the atmosphere without being routed to a flare or regenerator firebox/fire tubes? [98.236(e)(1)(xvii)]No


BlowdownVentStacksDetails:
mt CO28.8
mt CH486.95
Did the facility have any blowdown vent stacks subject to reporting under 98.232 [98.236(i)]?Yes
Were missing data procedures used for any parameters to calculate GHG emissions? [98.235]No
How were emissions determined? [98.236(i)]Calculated by equipment or event type


BlowdownEquipmentOrEventEmissionsRowDetails:
Equipment or event type [98.236(i)(1)] [98.236(i)(2)]Facility piping
Total number of blowdowns for equipment or event type, N [98.236(i)(1)(i)]0
Annual total CO2 emissions for each equipment or event type (mt CO2) [98.236(i)(1)(ii)]0
Annual total CH4 emissions for each equipment or event type (mt CH4) [98.236(i)(1)(iii)]0
Equipment or event type [98.236(i)(1)] [98.236(i)(2)]Pipeline venting
Total number of blowdowns for equipment or event type, N [98.236(i)(1)(i)]0
Annual total CO2 emissions for each equipment or event type (mt CO2) [98.236(i)(1)(ii)]0
Annual total CH4 emissions for each equipment or event type (mt CH4) [98.236(i)(1)(iii)]0
Equipment or event type [98.236(i)(1)] [98.236(i)(2)]Compressors
Total number of blowdowns for equipment or event type, N [98.236(i)(1)(i)]228
Annual total CO2 emissions for each equipment or event type (mt CO2) [98.236(i)(1)(ii)]7.8997704
Annual total CH4 emissions for each equipment or event type (mt CH4) [98.236(i)(1)(iii)]78.3054256
Equipment or event type [98.236(i)(1)] [98.236(i)(2)]Scrubbers/strainers
Total number of blowdowns for equipment or event type, N [98.236(i)(1)(i)]14
Annual total CO2 emissions for each equipment or event type (mt CO2) [98.236(i)(1)(ii)]0.0727348
Annual total CH4 emissions for each equipment or event type (mt CH4) [98.236(i)(1)(iii)]0.7209745
Equipment or event type [98.236(i)(1)] [98.236(i)(2)]Pig launchers and receivers
Total number of blowdowns for equipment or event type, N [98.236(i)(1)(i)]0
Annual total CO2 emissions for each equipment or event type (mt CO2) [98.236(i)(1)(ii)]0
Annual total CH4 emissions for each equipment or event type (mt CH4) [98.236(i)(1)(iii)]0
Equipment or event type [98.236(i)(1)] [98.236(i)(2)]Emergency shutdowns
Total number of blowdowns for equipment or event type, N [98.236(i)(1)(i)]0
Annual total CO2 emissions for each equipment or event type (mt CO2) [98.236(i)(1)(ii)]0
Annual total CH4 emissions for each equipment or event type (mt CH4) [98.236(i)(1)(iii)]0
Equipment or event type [98.236(i)(1)] [98.236(i)(2)]All other equipment with a physical volume greater than or equal 50 cubic feet
Total number of blowdowns for equipment or event type, N [98.236(i)(1)(i)]13
Annual total CO2 emissions for each equipment or event type (mt CO2) [98.236(i)(1)(ii)]0.799673
Annual total CH4 emissions for each equipment or event type (mt CH4) [98.236(i)(1)(iii)]7.9266528


FlareStacksDetails:
mt CO2436.5
mt CH43.18
mt N2O0.001
Did the facility have flare stacks subject to reporting under 98.232 [98.236(n)]?Yes
Were missing data procedures used for any parameters to calculate GHG emissions? [98.235]No


UniqueFlareStacksRowDetails:
Unique Name or ID Number for the Flare Stack [98.236(n)(1)]North Desoto
Does the flare stack have a continuous flow monitor on gas to the flare? [98.236(n)(2)]No
Does the flare stack have a continuous gas analyzer on gas to the flare? [98.236(n)(3)]No
Were CEMS used to measure CO2 emissions for the flare stack? [98.233(n)(8)] [98.236(n)(12)]No
Volume of gas sent to flare, Vs (standard cubic feet) [98.236(n)(4)]9841023.3
Flare combustion efficiency (decimal value) [98.236(n)(6)]0.98
Mole fraction of CH4 in flare feed gas, XCH4 [98.236(n)(7)]0.9756363
Mole fraction of CO2 in flare feed gas, XCO2 [98.236(n)(8)]0.0163257
Fraction of feed gas sent to un-lit flare, Zu [98.236(n)(5)]0
CO2 emissions (mt CO2) [98.236(n)(9)]436.4632432
CH4 Emissions (mt CH4) (Eq. W-19) [98.236(n)(10)]3.1786687
N2O Emissions (mt N2O) (Eq. W-40) [98.236(n)(11)]0.0010442


CentrifugalCompressorsDetails:
mt CO20.0
mt CH40.00
Did the facility have any centrifugal compressors subject to reporting under 98.232 [98.236(o)]?No


ReciprocatingCompressorsDetails:
mt CO26.4
mt CH4119.99
Did the facility have any reciprocating compressors subject to reporting under 98.232 [98.236(p)]?Yes
Were missing data procedures used for any parameters to calculate GHG emissions? [98.235]No


ReciprocatingCompressorsActivityDataRowDetails:
Unique name or ID for reciprocating compressor [98.236(p)(1)(i)]MC3554
Total time in operating-mode (hours) [98.236(p)(1)(ii)]7691
Total time in standby-pressurized-mode (hours) [98.236(p)(1)(iii)]1053
Total time in not-operating-depressurized-mode (hours) [98.236(p)(1)(iv)]16
Compressor measured in operating-mode? [98.236(p)(1)(v)]Yes
Compressor measured in standby-pressurized-mode? [98.236(p)(1)(vi)]No
Compressor measured in not-operating-depressurized-mode? [98.236(p)(1)(vii)]No
Compressor had blind flanges installed? [98.236(p)(1)(xii)]No
Power output of compressor driver (hp) [98.236(p)(1)(xiii)]1775
Compressor had scheduled depressurized shutdown during reporting year? [98.236(p)(1)(xiv)]Yes
Unique name or ID for reciprocating compressor [98.236(p)(1)(i)]MC3555
Total time in operating-mode (hours) [98.236(p)(1)(ii)]6822
Total time in standby-pressurized-mode (hours) [98.236(p)(1)(iii)]1878
Total time in not-operating-depressurized-mode (hours) [98.236(p)(1)(iv)]60
Compressor measured in operating-mode? [98.236(p)(1)(v)]Yes
Compressor measured in standby-pressurized-mode? [98.236(p)(1)(vi)]No
Compressor measured in not-operating-depressurized-mode? [98.236(p)(1)(vii)]No
Compressor had blind flanges installed? [98.236(p)(1)(xii)]No
Power output of compressor driver (hp) [98.236(p)(1)(xiii)]1775
Compressor had scheduled depressurized shutdown during reporting year? [98.236(p)(1)(xiv)]Yes
Unique name or ID for reciprocating compressor [98.236(p)(1)(i)]MC3556
Total time in operating-mode (hours) [98.236(p)(1)(ii)]2022
Total time in standby-pressurized-mode (hours) [98.236(p)(1)(iii)]6734
Total time in not-operating-depressurized-mode (hours) [98.236(p)(1)(iv)]4
Compressor measured in operating-mode? [98.236(p)(1)(v)]No
Compressor measured in standby-pressurized-mode? [98.236(p)(1)(vi)]No
Compressor measured in not-operating-depressurized-mode? [98.236(p)(1)(vii)]Yes
Compressor had blind flanges installed? [98.236(p)(1)(xii)]No
Power output of compressor driver (hp) [98.236(p)(1)(xiii)]1775
Compressor had scheduled depressurized shutdown during reporting year? [98.236(p)(1)(xiv)]Yes
Unique name or ID for reciprocating compressor [98.236(p)(1)(i)]MC3557
Total time in operating-mode (hours) [98.236(p)(1)(ii)]6765
Total time in standby-pressurized-mode (hours) [98.236(p)(1)(iii)]1931
Total time in not-operating-depressurized-mode (hours) [98.236(p)(1)(iv)]64
Compressor measured in operating-mode? [98.236(p)(1)(v)]Yes
Compressor measured in standby-pressurized-mode? [98.236(p)(1)(vi)]No
Compressor measured in not-operating-depressurized-mode? [98.236(p)(1)(vii)]No
Compressor had blind flanges installed? [98.236(p)(1)(xii)]No
Power output of compressor driver (hp) [98.236(p)(1)(xiii)]1775
Compressor had scheduled depressurized shutdown during reporting year? [98.236(p)(1)(xiv)]Yes
Unique name or ID for reciprocating compressor [98.236(p)(1)(i)]MC3558
Total time in operating-mode (hours) [98.236(p)(1)(ii)]6971
Total time in standby-pressurized-mode (hours) [98.236(p)(1)(iii)]1773
Total time in not-operating-depressurized-mode (hours) [98.236(p)(1)(iv)]16
Compressor measured in operating-mode? [98.236(p)(1)(v)]Yes
Compressor measured in standby-pressurized-mode? [98.236(p)(1)(vi)]No
Compressor measured in not-operating-depressurized-mode? [98.236(p)(1)(vii)]No
Compressor had blind flanges installed? [98.236(p)(1)(xii)]No
Power output of compressor driver (hp) [98.236(p)(1)(xiii)]1775
Compressor had scheduled depressurized shutdown during reporting year? [98.236(p)(1)(xiv)]Yes
Unique name or ID for reciprocating compressor [98.236(p)(1)(i)]MC3559
Total time in operating-mode (hours) [98.236(p)(1)(ii)]7587
Total time in standby-pressurized-mode (hours) [98.236(p)(1)(iii)]1109
Total time in not-operating-depressurized-mode (hours) [98.236(p)(1)(iv)]64
Compressor measured in operating-mode? [98.236(p)(1)(v)]Yes
Compressor measured in standby-pressurized-mode? [98.236(p)(1)(vi)]No
Compressor measured in not-operating-depressurized-mode? [98.236(p)(1)(vii)]No
Compressor had blind flanges installed? [98.236(p)(1)(xii)]No
Power output of compressor driver (hp) [98.236(p)(1)(xiii)]1775
Compressor had scheduled depressurized shutdown during reporting year? [98.236(p)(1)(xiv)]Yes
Unique name or ID for reciprocating compressor [98.236(p)(1)(i)]MC3560
Total time in operating-mode (hours) [98.236(p)(1)(ii)]3293
Total time in standby-pressurized-mode (hours) [98.236(p)(1)(iii)]5455
Total time in not-operating-depressurized-mode (hours) [98.236(p)(1)(iv)]12
Compressor measured in operating-mode? [98.236(p)(1)(v)]No
Compressor measured in standby-pressurized-mode? [98.236(p)(1)(vi)]No
Compressor measured in not-operating-depressurized-mode? [98.236(p)(1)(vii)]Yes
Compressor had blind flanges installed? [98.236(p)(1)(xii)]No
Power output of compressor driver (hp) [98.236(p)(1)(xiii)]1775
Compressor had scheduled depressurized shutdown during reporting year? [98.236(p)(1)(xiv)]Yes


ReciprocatingCompressorSourceRowDetails:
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]MC3554
Reciprocating compressor source [98.236(p)(2)(i)(B)]Blowdown valve
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]MC3554 BDV
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]MC3554
Reciprocating compressor source [98.236(p)(2)(i)(B)]Isolation valve
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]MC3554 ISO
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]MC3554
Reciprocating compressor source [98.236(p)(2)(i)(B)]Rod packing
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]MC3554 RPV
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]MC3555
Reciprocating compressor source [98.236(p)(2)(i)(B)]Blowdown valve
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]MC3555 BDV
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]MC3555
Reciprocating compressor source [98.236(p)(2)(i)(B)]Isolation valve
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]MC3555 ISO
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]MC3555
Reciprocating compressor source [98.236(p)(2)(i)(B)]Rod packing
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]MC3555 RPV
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]MC3556
Reciprocating compressor source [98.236(p)(2)(i)(B)]Blowdown valve
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]MC3556 BDV
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]MC3556
Reciprocating compressor source [98.236(p)(2)(i)(B)]Isolation valve
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]MC3556 ISO
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]MC3556
Reciprocating compressor source [98.236(p)(2)(i)(B)]Rod packing
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]MC3556 RPV
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]MC3557
Reciprocating compressor source [98.236(p)(2)(i)(B)]Blowdown valve
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]MC3557 BDV
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]MC3557
Reciprocating compressor source [98.236(p)(2)(i)(B)]Isolation valve
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]MC3557 ISO
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]MC3557
Reciprocating compressor source [98.236(p)(2)(i)(B)]Rod packing
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]MC3557 RPV
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]MC3558
Reciprocating compressor source [98.236(p)(2)(i)(B)]Blowdown valve
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]MC3558 BDV
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]MC3558
Reciprocating compressor source [98.236(p)(2)(i)(B)]Isolation valve
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]MC3558 ISO
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]MC3558
Reciprocating compressor source [98.236(p)(2)(i)(B)]Rod packing
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]MC3558 RPV
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]MC3559
Reciprocating compressor source [98.236(p)(2)(i)(B)]Blowdown valve
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]MC3559 BDV
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]MC3559
Reciprocating compressor source [98.236(p)(2)(i)(B)]Isolation valve
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]MC3559 ISO
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]MC3559
Reciprocating compressor source [98.236(p)(2)(i)(B)]Rod packing
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]MC3559 RPV
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]MC3560
Reciprocating compressor source [98.236(p)(2)(i)(B)]Blowdown valve
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]MC3560 BDV
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]MC3560
Reciprocating compressor source [98.236(p)(2)(i)(B)]Isolation valve
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]MC3560 ISO
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]MC3560
Reciprocating compressor source [98.236(p)(2)(i)(B)]Rod packing
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]MC3560 RPV


ReciprocatingCompressorsLeakOrVentSampleDataRowDetails:
Unique Name or ID for leak or vent (Specify) [98.236(p)(2)(i)(C)] [98.236(p)(3)(i)(A)]MC3554 BDV
Measurement date (mm/dd/yyyy) [98.236(p)(3)(i)(B)]2020-08-05
Measurement method [98.236(p)(3)(i)(C)]Screening/Optical gas imaging
Measured flow rate (standard cubic feet/hour) [98.236(p)(3)(i)(D)]0
Is the measurement location prior to or after commingling with non-compressor emission sources? [98.236(p)(3)(i)(F)]Not manifolded
Compressors in “Operating mode”MC3554
Unique Name or ID for leak or vent (Specify) [98.236(p)(2)(i)(C)] [98.236(p)(3)(i)(A)]MC3554 RPV
Measurement date (mm/dd/yyyy) [98.236(p)(3)(i)(B)]2020-08-05
Measurement method [98.236(p)(3)(i)(C)]High volume sampler
Measured flow rate (standard cubic feet/hour) [98.236(p)(3)(i)(D)]139.704
Is the measurement location prior to or after commingling with non-compressor emission sources? [98.236(p)(3)(i)(F)]Not manifolded
Compressors in “Operating mode”MC3554
Unique Name or ID for leak or vent (Specify) [98.236(p)(2)(i)(C)] [98.236(p)(3)(i)(A)]MC3555 BDV
Measurement date (mm/dd/yyyy) [98.236(p)(3)(i)(B)]2020-08-05
Measurement method [98.236(p)(3)(i)(C)]Screening/Optical gas imaging
Measured flow rate (standard cubic feet/hour) [98.236(p)(3)(i)(D)]0
Is the measurement location prior to or after commingling with non-compressor emission sources? [98.236(p)(3)(i)(F)]Not manifolded
Compressors in “Operating mode”MC3555
Unique Name or ID for leak or vent (Specify) [98.236(p)(2)(i)(C)] [98.236(p)(3)(i)(A)]MC3555 RPV
Measurement date (mm/dd/yyyy) [98.236(p)(3)(i)(B)]2020-08-05
Measurement method [98.236(p)(3)(i)(C)]High volume sampler
Measured flow rate (standard cubic feet/hour) [98.236(p)(3)(i)(D)]69.852
Is the measurement location prior to or after commingling with non-compressor emission sources? [98.236(p)(3)(i)(F)]Not manifolded
Compressors in “Operating mode”MC3555
Unique Name or ID for leak or vent (Specify) [98.236(p)(2)(i)(C)] [98.236(p)(3)(i)(A)]MC3556 ISO
Measurement date (mm/dd/yyyy) [98.236(p)(3)(i)(B)]2020-08-05
Measurement method [98.236(p)(3)(i)(C)]Screening/Optical gas imaging
Measured flow rate (standard cubic feet/hour) [98.236(p)(3)(i)(D)]0
Is the measurement location prior to or after commingling with non-compressor emission sources? [98.236(p)(3)(i)(F)]Not manifolded
Compressors in “Not-operating mode”MC3556
Unique Name or ID for leak or vent (Specify) [98.236(p)(2)(i)(C)] [98.236(p)(3)(i)(A)]MC3557 BDV
Measurement date (mm/dd/yyyy) [98.236(p)(3)(i)(B)]2020-08-05
Measurement method [98.236(p)(3)(i)(C)]Screening/Optical gas imaging
Measured flow rate (standard cubic feet/hour) [98.236(p)(3)(i)(D)]0
Is the measurement location prior to or after commingling with non-compressor emission sources? [98.236(p)(3)(i)(F)]Not manifolded
Compressors in “Operating mode”MC3557
Unique Name or ID for leak or vent (Specify) [98.236(p)(2)(i)(C)] [98.236(p)(3)(i)(A)]MC3557 RPV
Measurement date (mm/dd/yyyy) [98.236(p)(3)(i)(B)]2020-08-05
Measurement method [98.236(p)(3)(i)(C)]High volume sampler
Measured flow rate (standard cubic feet/hour) [98.236(p)(3)(i)(D)]202.989
Is the measurement location prior to or after commingling with non-compressor emission sources? [98.236(p)(3)(i)(F)]Not manifolded
Compressors in “Operating mode”MC3557
Unique Name or ID for leak or vent (Specify) [98.236(p)(2)(i)(C)] [98.236(p)(3)(i)(A)]MC3558 BDV
Measurement date (mm/dd/yyyy) [98.236(p)(3)(i)(B)]2020-08-05
Measurement method [98.236(p)(3)(i)(C)]High volume sampler
Measured flow rate (standard cubic feet/hour) [98.236(p)(3)(i)(D)]11.941
Is the measurement location prior to or after commingling with non-compressor emission sources? [98.236(p)(3)(i)(F)]Not manifolded
Compressors in “Operating mode”MC3558
Unique Name or ID for leak or vent (Specify) [98.236(p)(2)(i)(C)] [98.236(p)(3)(i)(A)]MC3558 RPV
Measurement date (mm/dd/yyyy) [98.236(p)(3)(i)(B)]2020-08-05
Measurement method [98.236(p)(3)(i)(C)]High volume sampler
Measured flow rate (standard cubic feet/hour) [98.236(p)(3)(i)(D)]171.346
Is the measurement location prior to or after commingling with non-compressor emission sources? [98.236(p)(3)(i)(F)]Not manifolded
Compressors in “Operating mode”MC3558
Unique Name or ID for leak or vent (Specify) [98.236(p)(2)(i)(C)] [98.236(p)(3)(i)(A)]MC3559 BDV
Measurement date (mm/dd/yyyy) [98.236(p)(3)(i)(B)]2020-08-05
Measurement method [98.236(p)(3)(i)(C)]Screening/Optical gas imaging
Measured flow rate (standard cubic feet/hour) [98.236(p)(3)(i)(D)]0
Is the measurement location prior to or after commingling with non-compressor emission sources? [98.236(p)(3)(i)(F)]Not manifolded
Compressors in “Operating mode”MC3559
Unique Name or ID for leak or vent (Specify) [98.236(p)(2)(i)(C)] [98.236(p)(3)(i)(A)]MC3559 RPV
Measurement date (mm/dd/yyyy) [98.236(p)(3)(i)(B)]2020-08-05
Measurement method [98.236(p)(3)(i)(C)]High volume sampler
Measured flow rate (standard cubic feet/hour) [98.236(p)(3)(i)(D)]139.107
Is the measurement location prior to or after commingling with non-compressor emission sources? [98.236(p)(3)(i)(F)]Not manifolded
Compressors in “Operating mode”MC3559
Unique Name or ID for leak or vent (Specify) [98.236(p)(2)(i)(C)] [98.236(p)(3)(i)(A)]MC3560 ISO
Measurement date (mm/dd/yyyy) [98.236(p)(3)(i)(B)]2020-08-05
Measurement method [98.236(p)(3)(i)(C)]High volume sampler
Measured flow rate (standard cubic feet/hour) [98.236(p)(3)(i)(D)]177.914
Is the measurement location prior to or after commingling with non-compressor emission sources? [98.236(p)(3)(i)(F)]Not manifolded
Compressors in “Not-operating mode”MC3560


ReciprocatingCompressorsEmissionFactorsSampleDataRowDetails:
Compressor Mode [98.236(p)(3)(ii)(A)]Operating
Compressor Source [98.236(p)(3)(ii)(A)]Blowdown valve
Compressor mode-source combination reporter emission factor, EFs,m (standard cubic feet per hour) [98.236(p)(3)(ii)(B)]17.0706308
Total number of compressors measured in the compressor mode-source combination in current reporting year and preceding two reporting years, Countm [98.236(p)(3)(ii)(C)]65
Is the reporter emission factor facility-specific or based on all of the reporter's applicable facilities? [98.236(p)(3)(ii)(D)]All applicable facilities
Compressor Mode [98.236(p)(3)(ii)(A)]Operating
Compressor Source [98.236(p)(3)(ii)(A)]Rod packing
Compressor mode-source combination reporter emission factor, EFs,m (standard cubic feet per hour) [98.236(p)(3)(ii)(B)]191.2312194
Total number of compressors measured in the compressor mode-source combination in current reporting year and preceding two reporting years, Countm [98.236(p)(3)(ii)(C)]155
Is the reporter emission factor facility-specific or based on all of the reporter's applicable facilities? [98.236(p)(3)(ii)(D)]All applicable facilities
Compressor Mode [98.236(p)(3)(ii)(A)]Standby-pressurized
Compressor Source [98.236(p)(3)(ii)(A)]Blowdown valve
Compressor mode-source combination reporter emission factor, EFs,m (standard cubic feet per hour) [98.236(p)(3)(ii)(B)]0.6671429
Total number of compressors measured in the compressor mode-source combination in current reporting year and preceding two reporting years, Countm [98.236(p)(3)(ii)(C)]21
Is the reporter emission factor facility-specific or based on all of the reporter's applicable facilities? [98.236(p)(3)(ii)(D)]All applicable facilities
Compressor Mode [98.236(p)(3)(ii)(A)]Not-operating-depressurized
Compressor Source [98.236(p)(3)(ii)(A)]Isolation valve
Compressor mode-source combination reporter emission factor, EFs,m (standard cubic feet per hour) [98.236(p)(3)(ii)(B)]16.222
Total number of compressors measured in the compressor mode-source combination in current reporting year and preceding two reporting years, Countm [98.236(p)(3)(ii)(C)]28
Is the reporter emission factor facility-specific or based on all of the reporter's applicable facilities? [98.236(p)(3)(ii)(D)]All applicable facilities


ReciprocatingCompressorsLeakOrVentDataRowDetails:
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]MC3554 BDV
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]Yes
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)]0.0007021
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)]0.0132053
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]MC3554 ISO
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]No
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)]0.0002594
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)]0.0048789
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]MC3554 RPV
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]Yes
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)]1.0738188
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)]20.1973
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]MC3555 BDV
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]Yes
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)]0.0012521
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)]0.0235514
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]MC3555 ISO
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]No
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)]0.0009727
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)]0.018296
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]MC3555 RPV
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]Yes
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)]0.4762444
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)]8.9576115
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]MC3556 BDV
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]No
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)]0.0389859
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)]0.733281
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]MC3556 ISO
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]Yes
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)]0
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)]0
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]MC3556 RPV
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]No
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)]0.3864375
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)]7.2684467
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]MC3557 BDV
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]Yes
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)]0.0012875
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)]0.024216
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]MC3557 ISO
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]No
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)]0.0010376
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)]0.0195158
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]MC3557 RPV
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]Yes
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)]1.3723967
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)]25.8132073
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]MC3558 BDV
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]Yes
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)]0.0843729
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)]1.5869575
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]MC3558 ISO
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]No
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)]0.0002594
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)]0.0048789
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]MC3558 RPV
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]Yes
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)]1.1937363
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)]22.4528109
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]MC3559 BDV
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]Yes
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)]0.0007394
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)]0.0139076
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]MC3559 ISO
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]No
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)]0.0010376
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)]0.0195158
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]MC3559 RPV
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]Yes
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)]1.0547716
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)]19.8390437
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]MC3560 BDV
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]No
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)]0.0598169
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)]1.125088
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]MC3560 ISO
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]Yes
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)]0.0021337
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)]0.0401322
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]MC3560 RPV
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]No
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)]0.6293466
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)]11.8372873


OtherEmissionsFromEquipmentLeaksDetails:
mt CO20.5
mt CH45.22
Did this facility use leak surveys to calculate emissions from equipment leaks in accordance with 98.232 [per 98.236(q)]?Yes
Were missing data procedures used for any parameters to calculate GHG emissions? [98.235]No
Number of complete equipment leak surveys performed during the calendar year [98.236(q)(1)(i)]1
Optical gas imaging instrument as specified in §60.18 [98.234(a)(1)]Yes
Method 21 [98.234(a)(2)]No
Infrared laser beam illuminated instrument [98.234(a)(3)]No
Acoustic leak detection device [98.234(a)(5)]No
Optical gas imaging instrument as specified in §60.5397a [98.234(a)(6)]No
Method 21 as specified in §60.5397a [98.234(a)(7)]No


GasProcessingEmissionsFactorsRowDetails:
Component Type [98.236(q)(2)(i)]Compressor Components, Gas Service - Valve
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)]0
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)]0
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)]0
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)]0
Component Type [98.236(q)(2)(i)]Compressor Components, Gas Service - Connector
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)]0
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)]0
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)]0
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)]0
Component Type [98.236(q)(2)(i)]Compressor Components, Gas Service - Open-ended Line
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)]0
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)]0
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)]0
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)]0
Component Type [98.236(q)(2)(i)]Compressor Components, Gas Service - Pressure Relief Valve
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)]0
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)]0
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)]0
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)]0
Component Type [98.236(q)(2)(i)]Compressor Components, Gas Service - Meter
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)]0
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)]0
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)]0
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)]0
Component Type [98.236(q)(2)(i)]Non-Compressor Components, Gas Service - Valve
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)]1
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)]8784
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)]0.1050065
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)]1.0420395
Component Type [98.236(q)(2)(i)]Non-Compressor Components, Gas Service - Connector
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)]4
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)]8784
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)]0.3735747
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)]3.7071936
Component Type [98.236(q)(2)(i)]Non-Compressor Components, Gas Service - Open-ended Line
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)]0
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)]0
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)]0
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)]0
Component Type [98.236(q)(2)(i)]Non-Compressor components, Gas Service - Pressure Relief Valve
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)]0
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)]0
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)]0
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)]0
Component Type [98.236(q)(2)(i)]Non-Compressor components, Gas Service - Meter
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)]1
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)]8784
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)]0.0479235
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)]0.4755726