Source Reporting Form | Onshore Production [98.236(aa)(1)] |
Required for Selected Industry Segment | No |
Source Reporting Form | Facility Overview [98.236(aa)(2-11)] |
Required for Selected Industry Segment | Yes |
Source Reporting Form | Natural Gas Pneumatic Devices [98.236(b)] |
Required for Selected Industry Segment | No |
Total Reported CO2 Emissions (mt CO2) | 0.0 |
Total Reported CH4 Emissions (mt CH4) | 0.00 |
Source Reporting Form | Natural Gas Driven Pneumatic Pumps [98.236(c)] |
Required for Selected Industry Segment | No |
Total Reported CO2 Emissions (mt CO2) | 0.0 |
Total Reported CH4 Emissions (mt CH4) | 0.00 |
Source Reporting Form | Acid Gas Removal Units [98.236(d)] |
Required for Selected Industry Segment | Yes |
Total Reported CO2 Emissions (mt CO2) | 142772.2 |
Source Reporting Form | Dehydrators [98.236(e)] |
Required for Selected Industry Segment | Yes |
Total Reported CO2 Emissions (mt CO2) | 1004.7 |
Total Reported CH4 Emissions (mt CH4) | 19.04 |
Total Reported N2O Emissions (mt N2O) | 0.002 |
Source Reporting Form | Well Venting for Liquids Unloading [98.236(f)] |
Required for Selected Industry Segment | No |
Total Reported CO2 Emissions (mt CO2) | 0.0 |
Total Reported CH4 Emissions (mt CH4) | 0.00 |
Source Reporting Form | Completions and Workovers with Hydraulic Fracturing [98.236(g)] |
Required for Selected Industry Segment | No |
Total Reported CO2 Emissions (mt CO2) | 0.0 |
Total Reported CH4 Emissions (mt CH4) | 0.00 |
Total Reported N2O Emissions (mt N2O) | 0.000 |
Source Reporting Form | Completions and Workovers without Hydraulic Fracturing [98.236(h)] |
Required for Selected Industry Segment | No |
Total Reported CO2 Emissions (mt CO2) | 0.0 |
Total Reported CH4 Emissions (mt CH4) | 0.00 |
Total Reported N2O Emissions (mt N2O) | 0.000 |
Source Reporting Form | Blowdown Vent Stacks [98.236(i)] |
Required for Selected Industry Segment | Yes |
Total Reported CO2 Emissions (mt CO2) | 8.8 |
Total Reported CH4 Emissions (mt CH4) | 86.95 |
Source Reporting Form | Atmospheric Storage Tanks [98.236(j)] |
Required for Selected Industry Segment | No |
Total Reported CO2 Emissions (mt CO2) | 0.0 |
Total Reported CH4 Emissions (mt CH4) | 0.00 |
Total Reported N2O Emissions (mt N2O) | 0.000 |
Source Reporting Form | Transmission Storage Tanks [98.236(k)] |
Required for Selected Industry Segment | No |
Total Reported CO2 Emissions (mt CO2) | 0.0 |
Total Reported CH4 Emissions (mt CH4) | 0.00 |
Total Reported N2O Emissions (mt N2O) | 0.000 |
Source Reporting Form | Well Testing [98.236(l)] |
Required for Selected Industry Segment | No |
Total Reported CO2 Emissions (mt CO2) | 0.0 |
Total Reported CH4 Emissions (mt CH4) | 0.00 |
Total Reported N2O Emissions (mt N2O) | 0.000 |
Source Reporting Form | Associated Gas Venting and Flaring [98.236(m)] |
Required for Selected Industry Segment | No |
Total Reported CO2 Emissions (mt CO2) | 0.0 |
Total Reported CH4 Emissions (mt CH4) | 0.00 |
Total Reported N2O Emissions (mt N2O) | 0.000 |
Source Reporting Form | Flare Stacks [98.236(n)] |
Required for Selected Industry Segment | Yes |
Total Reported CO2 Emissions (mt CO2) | 436.5 |
Total Reported CH4 Emissions (mt CH4) | 3.18 |
Total Reported N2O Emissions (mt N2O) | 0.001 |
Source Reporting Form | Centrifugal Compressors [98.236(o)] |
Required for Selected Industry Segment | Yes |
Total Reported CO2 Emissions (mt CO2) | 0.0 |
Total Reported CH4 Emissions (mt CH4) | 0.00 |
Source Reporting Form | Reciprocating Compressors [98.236(p)] |
Required for Selected Industry Segment | Yes |
Total Reported CO2 Emissions (mt CO2) | 6.4 |
Total Reported CH4 Emissions (mt CH4) | 119.99 |
Source Reporting Form | Equipment Leaks Surveys and Population Counts [98.236(q,r)] |
Required for Selected Industry Segment | Yes |
Total Reported CO2 Emissions (mt CO2) | 0.5 |
Total Reported CH4 Emissions (mt CH4) | 5.22 |
Source Reporting Form | Offshore Petroleum and Natural Gas Production [98.236(s)] |
Required for Selected Industry Segment | No |
Total Reported CO2 Emissions (mt CO2) | 0.0 |
Total Reported CH4 Emissions (mt CH4) | 0.00 |
Total Reported N2O Emissions (mt N2O) | 0.000 |
Source Reporting Form | Enhanced Oil Recovery Injection Pumps [98.236(w)] |
Required for Selected Industry Segment | No |
Total Reported CO2 Emissions (mt CO2) | 0.0 |
Source Reporting Form | Enhanced Oil Recovery Hydrocarbon Liquids [98.236(x)] |
Required for Selected Industry Segment | No |
Total Reported CO2 Emissions (mt CO2) | 0.0 |
Source Reporting Form | Combustion Equipment at Onshore Petroleum and Natural Gas Production Facilities, Onshore Petroleum and Natural Gas Gathering and Boosting Facilities, and Natural gas Distribution Facilities [98.236(z)] |
Required for Selected Industry Segment | No |
Total Reported CO2 Emissions (mt CO2) | 0.0 |
Total Reported CH4 Emissions (mt CH4) | 0.00 |
Total Reported N2O Emissions (mt N2O) | 0.000 |
Unit ID or Name [98.236(d)(1)(i)] | Amine 1A |
Name of simulation software package used [98.236(d)(2)(iii)(A)] | AmineCalc |
Natural gas feed temperature (°F) [98.236(d)(2)(iii)(B)] | 74 |
Natural gas feed pressure (psi) [98.236(d)(2)(iii)(C)] | 1008 |
Natural gas feed flow rate (standard cubic feet per minute) [98.236(d)(2)(iii)(D)] | 25465.9710414 |
Acid gas content of feed natural gas (mole percent) [98.236(d)(2)(iii)(E)] | 3.62 |
Acid gas content of outlet natural gas (mole percent) [98.236(d)(2)(iii)(F)] | 0.007 |
Unit operating hours (excluding downtime for maintenance or standby) [98.236(d)(2)(iii)(G)] | 6469 |
Exit temperature of the natural gas (°F) [98.236(d)(2)(iii)(H)] | 114 |
Solvent pressure (psi) [98.236(d)(2)(iii)(I)] | 1008 |
Solvent temperature (°F) [98.236(d)(2)(iii)(J)] | 114 |
Solvent circulation rate (gallons per minute) [98.236(d)(2)(iii)(K)] | 276 |
Solvent weight (pounds per gallon) [98.236(d)(2)(iii)(L)] | 8.6926819 |
Unit ID or Name [98.236(d)(1)(i)] | Amine 1B |
Name of simulation software package used [98.236(d)(2)(iii)(A)] | AmineCalc |
Natural gas feed temperature (°F) [98.236(d)(2)(iii)(B)] | 74 |
Natural gas feed pressure (psi) [98.236(d)(2)(iii)(C)] | 1008 |
Natural gas feed flow rate (standard cubic feet per minute) [98.236(d)(2)(iii)(D)] | 35631.7823192 |
Acid gas content of feed natural gas (mole percent) [98.236(d)(2)(iii)(E)] | 3.6173 |
Acid gas content of outlet natural gas (mole percent) [98.236(d)(2)(iii)(F)] | 0.005 |
Unit operating hours (excluding downtime for maintenance or standby) [98.236(d)(2)(iii)(G)] | 8784 |
Exit temperature of the natural gas (°F) [98.236(d)(2)(iii)(H)] | 114 |
Solvent pressure (psi) [98.236(d)(2)(iii)(I)] | 1008 |
Solvent temperature (°F) [98.236(d)(2)(iii)(J)] | 114 |
Solvent circulation rate (gallons per minute) [98.236(d)(2)(iii)(K)] | 334 |
Solvent weight (pounds per gallon) [98.236(d)(2)(iii)(L)] | 8.6926819 |
Unit ID or Name [98.236(d)(1)(i)] | Amine 2A |
Name of simulation software package used [98.236(d)(2)(iii)(A)] | AmineCalc |
Natural gas feed temperature (°F) [98.236(d)(2)(iii)(B)] | 74 |
Natural gas feed pressure (psi) [98.236(d)(2)(iii)(C)] | 1003 |
Natural gas feed flow rate (standard cubic feet per minute) [98.236(d)(2)(iii)(D)] | 44323.0115361 |
Acid gas content of feed natural gas (mole percent) [98.236(d)(2)(iii)(E)] | 3.6173 |
Acid gas content of outlet natural gas (mole percent) [98.236(d)(2)(iii)(F)] | 0.005 |
Unit operating hours (excluding downtime for maintenance or standby) [98.236(d)(2)(iii)(G)] | 8784 |
Exit temperature of the natural gas (°F) [98.236(d)(2)(iii)(H)] | 114 |
Solvent pressure (psi) [98.236(d)(2)(iii)(I)] | 1003 |
Solvent temperature (°F) [98.236(d)(2)(iii)(J)] | 114 |
Solvent circulation rate (gallons per minute) [98.236(d)(2)(iii)(K)] | 380 |
Solvent weight (pounds per gallon) [98.236(d)(2)(iii)(L)] | 8.6926819 |
Unit ID or Name [98.236(d)(1)(i)] | Amine 2B |
Name of simulation software package used [98.236(d)(2)(iii)(A)] | AmineCalc |
Natural gas feed temperature (°F) [98.236(d)(2)(iii)(B)] | 74 |
Natural gas feed pressure (psi) [98.236(d)(2)(iii)(C)] | 1003 |
Natural gas feed flow rate (standard cubic feet per minute) [98.236(d)(2)(iii)(D)] | 43942.1106557 |
Acid gas content of feed natural gas (mole percent) [98.236(d)(2)(iii)(E)] | 3.6173 |
Acid gas content of outlet natural gas (mole percent) [98.236(d)(2)(iii)(F)] | 0.005 |
Unit operating hours (excluding downtime for maintenance or standby) [98.236(d)(2)(iii)(G)] | 8784 |
Exit temperature of the natural gas (°F) [98.236(d)(2)(iii)(H)] | 114 |
Solvent pressure (psi) [98.236(d)(2)(iii)(I)] | 1003 |
Solvent temperature (°F) [98.236(d)(2)(iii)(J)] | 114 |
Solvent circulation rate (gallons per minute) [98.236(d)(2)(iii)(K)] | 379 |
Solvent weight (pounds per gallon) [98.236(d)(2)(iii)(L)] | 8.6926819 |
Unit ID or Name [98.236(e)(1)(i)] | Haynesville - North Desoto -- NG Plant --- DE SOTO, LA (31) 230 - Dehy D Train 2 (Central Processing Worksheet) |
Sub-Basin ID [98.236(e)(1)(xviii] | Not G&B |
Glycol dehydrator feed natural gas flow rate determined by engineering estimate based on best available data (MMscfd) [98.236(e)(1)(ii)] | 63.293 |
Dehydrator feed natural gas water content (pounds per MMscf) [98.236(e)(1)(iii)] | 28.69 |
Dehydrator outlet natural gas water content (pounds per MMscf) [98.236(e)(1)(iv)] | 1.29 |
Glycol dehydrator absorbent circulation pump type [98.236(e)(1)(v)] | Electric/Pneumatic |
Dehydrator absorbent circulation rate (gallons per minute) [98.236(e)(1)(vi)] | 8 |
Report type of absorbent used [98.236(e)(1)(vii)] | Triethylene glycol (TEG) |
Report whether stripper gas is used in glycol dehydrator [98.236(e)(1)(viii)] | No |
Report whether a flash tank separator is used in glycol dehydrator [98.236(e)(1)(ix)] | Yes |
Total time the glycol dehydrator is operating (hours) [98.236(e)(1)(x)] | 7201 |
Temperature of the wet natural gas (°F) [98.236(e)(1)(xi)] | 76 |
Pressure of the wet natural gas (psig) [98.236(e)(1)(xii)] | 967 |
Concentration of CO2 in wet natural gas (mole fraction) [98.236(e)(1)(xiv)] | 0 |
Concentration of CH4 in wet natural gas (mole fraction) [98.236(e)(1)(xiii)] | 0.997 |
Were any dehydrator emissions vented to a vapor recovery device? [98.236(e)(1)(xv)] | No |
Were any dehydrator emissions vented to a flare or regenerator firebox/fire tubes? [98.236(e)(1)(xvi)] | Yes |
CO2 Emissions from Flares or Regenerators (mt CO2) [98.236(e)(1)(xvi)(A)] | 124.7548647 |
CH4 Emissions from Flares or Regenerators (mt CH4) [98.236(e)(1)(xvi)(B)] | 2.3647131 |
N2O Emissions from Flares or Regenerators (mt N2O) [98.236(e)(1)(xvi)(C)] | 0.0002915 |
Were any dehydrator emissions vented to the atmosphere without being routed to a flare or regenerator firebox/fire tubes? [98.236(e)(1)(xvii)] | No |
Unit ID or Name [98.236(e)(1)(i)] | Haynesville - North Desoto -- NG Plant --- DE SOTO, LA (31) 230 - DehyA - Train1 (Central Processing Worksheet) |
Sub-Basin ID [98.236(e)(1)(xviii] | Not G&B |
Glycol dehydrator feed natural gas flow rate determined by engineering estimate based on best available data (MMscfd) [98.236(e)(1)(ii)] | 47.496 |
Dehydrator feed natural gas water content (pounds per MMscf) [98.236(e)(1)(iii)] | 28.69 |
Dehydrator outlet natural gas water content (pounds per MMscf) [98.236(e)(1)(iv)] | 1.17 |
Glycol dehydrator absorbent circulation pump type [98.236(e)(1)(v)] | Electric |
Dehydrator absorbent circulation rate (gallons per minute) [98.236(e)(1)(vi)] | 8 |
Report type of absorbent used [98.236(e)(1)(vii)] | Triethylene glycol (TEG) |
Report whether stripper gas is used in glycol dehydrator [98.236(e)(1)(viii)] | No |
Report whether a flash tank separator is used in glycol dehydrator [98.236(e)(1)(ix)] | Yes |
Total time the glycol dehydrator is operating (hours) [98.236(e)(1)(x)] | 6345 |
Temperature of the wet natural gas (°F) [98.236(e)(1)(xi)] | 76 |
Pressure of the wet natural gas (psig) [98.236(e)(1)(xii)] | 967 |
Concentration of CO2 in wet natural gas (mole fraction) [98.236(e)(1)(xiv)] | 0 |
Concentration of CH4 in wet natural gas (mole fraction) [98.236(e)(1)(xiii)] | 0.997 |
Were any dehydrator emissions vented to a vapor recovery device? [98.236(e)(1)(xv)] | No |
Were any dehydrator emissions vented to a flare or regenerator firebox/fire tubes? [98.236(e)(1)(xvi)] | Yes |
CO2 Emissions from Flares or Regenerators (mt CO2) [98.236(e)(1)(xvi)(A)] | 129.6833473 |
CH4 Emissions from Flares or Regenerators (mt CH4) [98.236(e)(1)(xvi)(B)] | 2.4550176 |
N2O Emissions from Flares or Regenerators (mt N2O) [98.236(e)(1)(xvi)(C)] | 0.0003024 |
Were any dehydrator emissions vented to the atmosphere without being routed to a flare or regenerator firebox/fire tubes? [98.236(e)(1)(xvii)] | No |
Unit ID or Name [98.236(e)(1)(i)] | Haynesville - North Desoto -- NG Plant --- DE SOTO, LA (31) 230 - DehyA - Train2 (Central Processing Worksheet) |
Sub-Basin ID [98.236(e)(1)(xviii] | Not G&B |
Glycol dehydrator feed natural gas flow rate determined by engineering estimate based on best available data (MMscfd) [98.236(e)(1)(ii)] | 65.299 |
Dehydrator feed natural gas water content (pounds per MMscf) [98.236(e)(1)(iii)] | 28.69 |
Dehydrator outlet natural gas water content (pounds per MMscf) [98.236(e)(1)(iv)] | 1.25 |
Glycol dehydrator absorbent circulation pump type [98.236(e)(1)(v)] | Electric |
Dehydrator absorbent circulation rate (gallons per minute) [98.236(e)(1)(vi)] | 9 |
Report type of absorbent used [98.236(e)(1)(vii)] | Triethylene glycol (TEG) |
Report whether stripper gas is used in glycol dehydrator [98.236(e)(1)(viii)] | No |
Report whether a flash tank separator is used in glycol dehydrator [98.236(e)(1)(ix)] | Yes |
Total time the glycol dehydrator is operating (hours) [98.236(e)(1)(x)] | 7337 |
Temperature of the wet natural gas (°F) [98.236(e)(1)(xi)] | 76 |
Pressure of the wet natural gas (psig) [98.236(e)(1)(xii)] | 967 |
Concentration of CO2 in wet natural gas (mole fraction) [98.236(e)(1)(xiv)] | 0 |
Concentration of CH4 in wet natural gas (mole fraction) [98.236(e)(1)(xiii)] | 0.997 |
Were any dehydrator emissions vented to a vapor recovery device? [98.236(e)(1)(xv)] | No |
Were any dehydrator emissions vented to a flare or regenerator firebox/fire tubes? [98.236(e)(1)(xvi)] | Yes |
CO2 Emissions from Flares or Regenerators (mt CO2) [98.236(e)(1)(xvi)(A)] | 141.4491483 |
CH4 Emissions from Flares or Regenerators (mt CH4) [98.236(e)(1)(xvi)(B)] | 2.6822203 |
N2O Emissions from Flares or Regenerators (mt N2O) [98.236(e)(1)(xvi)(C)] | 0.0003307 |
Were any dehydrator emissions vented to the atmosphere without being routed to a flare or regenerator firebox/fire tubes? [98.236(e)(1)(xvii)] | No |
Unit ID or Name [98.236(e)(1)(i)] | Haynesville - North Desoto -- NG Plant --- DE SOTO, LA (31) 230 - DehyB - Train1 (Central Processing Worksheet) |
Sub-Basin ID [98.236(e)(1)(xviii] | Not G&B |
Glycol dehydrator feed natural gas flow rate determined by engineering estimate based on best available data (MMscfd) [98.236(e)(1)(ii)] | 56.49 |
Dehydrator feed natural gas water content (pounds per MMscf) [98.236(e)(1)(iii)] | 28.69 |
Dehydrator outlet natural gas water content (pounds per MMscf) [98.236(e)(1)(iv)] | 1.24 |
Glycol dehydrator absorbent circulation pump type [98.236(e)(1)(v)] | Electric |
Dehydrator absorbent circulation rate (gallons per minute) [98.236(e)(1)(vi)] | 8 |
Report type of absorbent used [98.236(e)(1)(vii)] | Triethylene glycol (TEG) |
Report whether stripper gas is used in glycol dehydrator [98.236(e)(1)(viii)] | No |
Report whether a flash tank separator is used in glycol dehydrator [98.236(e)(1)(ix)] | Yes |
Total time the glycol dehydrator is operating (hours) [98.236(e)(1)(x)] | 7292 |
Temperature of the wet natural gas (°F) [98.236(e)(1)(xi)] | 76 |
Pressure of the wet natural gas (psig) [98.236(e)(1)(xii)] | 967 |
Concentration of CO2 in wet natural gas (mole fraction) [98.236(e)(1)(xiv)] | 0 |
Concentration of CH4 in wet natural gas (mole fraction) [98.236(e)(1)(xiii)] | 0.997 |
Were any dehydrator emissions vented to a vapor recovery device? [98.236(e)(1)(xv)] | No |
Were any dehydrator emissions vented to a flare or regenerator firebox/fire tubes? [98.236(e)(1)(xvi)] | Yes |
CO2 Emissions from Flares or Regenerators (mt CO2) [98.236(e)(1)(xvi)(A)] | 125.2226211 |
CH4 Emissions from Flares or Regenerators (mt CH4) [98.236(e)(1)(xvi)(B)] | 2.3745295 |
N2O Emissions from Flares or Regenerators (mt N2O) [98.236(e)(1)(xvi)(C)] | 0.0002928 |
Were any dehydrator emissions vented to the atmosphere without being routed to a flare or regenerator firebox/fire tubes? [98.236(e)(1)(xvii)] | No |
Unit ID or Name [98.236(e)(1)(i)] | Haynesville - North Desoto -- NG Plant --- DE SOTO, LA (31) 230 - DehyB - Train2 (Central Processing Worksheet) |
Sub-Basin ID [98.236(e)(1)(xviii] | Not G&B |
Glycol dehydrator feed natural gas flow rate determined by engineering estimate based on best available data (MMscfd) [98.236(e)(1)(ii)] | 63.471 |
Dehydrator feed natural gas water content (pounds per MMscf) [98.236(e)(1)(iii)] | 28.69 |
Dehydrator outlet natural gas water content (pounds per MMscf) [98.236(e)(1)(iv)] | 1.29 |
Glycol dehydrator absorbent circulation pump type [98.236(e)(1)(v)] | Electric/Pneumatic |
Dehydrator absorbent circulation rate (gallons per minute) [98.236(e)(1)(vi)] | 8 |
Report type of absorbent used [98.236(e)(1)(vii)] | Triethylene glycol (TEG) |
Report whether stripper gas is used in glycol dehydrator [98.236(e)(1)(viii)] | No |
Report whether a flash tank separator is used in glycol dehydrator [98.236(e)(1)(ix)] | Yes |
Total time the glycol dehydrator is operating (hours) [98.236(e)(1)(x)] | 6396 |
Temperature of the wet natural gas (°F) [98.236(e)(1)(xi)] | 76 |
Pressure of the wet natural gas (psig) [98.236(e)(1)(xii)] | 967 |
Concentration of CO2 in wet natural gas (mole fraction) [98.236(e)(1)(xiv)] | 0 |
Concentration of CH4 in wet natural gas (mole fraction) [98.236(e)(1)(xiii)] | 0.997 |
Were any dehydrator emissions vented to a vapor recovery device? [98.236(e)(1)(xv)] | No |
Were any dehydrator emissions vented to a flare or regenerator firebox/fire tubes? [98.236(e)(1)(xvi)] | Yes |
CO2 Emissions from Flares or Regenerators (mt CO2) [98.236(e)(1)(xvi)(A)] | 109.8514436 |
CH4 Emissions from Flares or Regenerators (mt CH4) [98.236(e)(1)(xvi)(B)] | 2.076219 |
N2O Emissions from Flares or Regenerators (mt N2O) [98.236(e)(1)(xvi)(C)] | 0.000256 |
Were any dehydrator emissions vented to the atmosphere without being routed to a flare or regenerator firebox/fire tubes? [98.236(e)(1)(xvii)] | No |
Unit ID or Name [98.236(e)(1)(i)] | Haynesville - North Desoto -- NG Plant --- DE SOTO, LA (31) 230 - DehyC - Train1 (Central Processing Worksheet) |
Sub-Basin ID [98.236(e)(1)(xviii] | Not G&B |
Glycol dehydrator feed natural gas flow rate determined by engineering estimate based on best available data (MMscfd) [98.236(e)(1)(ii)] | 67.22 |
Dehydrator feed natural gas water content (pounds per MMscf) [98.236(e)(1)(iii)] | 28.69 |
Dehydrator outlet natural gas water content (pounds per MMscf) [98.236(e)(1)(iv)] | 1.27 |
Glycol dehydrator absorbent circulation pump type [98.236(e)(1)(v)] | Electric |
Dehydrator absorbent circulation rate (gallons per minute) [98.236(e)(1)(vi)] | 9 |
Report type of absorbent used [98.236(e)(1)(vii)] | Triethylene glycol (TEG) |
Report whether stripper gas is used in glycol dehydrator [98.236(e)(1)(viii)] | No |
Report whether a flash tank separator is used in glycol dehydrator [98.236(e)(1)(ix)] | Yes |
Total time the glycol dehydrator is operating (hours) [98.236(e)(1)(x)] | 6713.5 |
Temperature of the wet natural gas (°F) [98.236(e)(1)(xi)] | 76 |
Pressure of the wet natural gas (psig) [98.236(e)(1)(xii)] | 967 |
Concentration of CO2 in wet natural gas (mole fraction) [98.236(e)(1)(xiv)] | 0 |
Concentration of CH4 in wet natural gas (mole fraction) [98.236(e)(1)(xiii)] | 0.997 |
Were any dehydrator emissions vented to a vapor recovery device? [98.236(e)(1)(xv)] | No |
Were any dehydrator emissions vented to a flare or regenerator firebox/fire tubes? [98.236(e)(1)(xvi)] | Yes |
CO2 Emissions from Flares or Regenerators (mt CO2) [98.236(e)(1)(xvi)(A)] | 129.4291368 |
CH4 Emissions from Flares or Regenerators (mt CH4) [98.236(e)(1)(xvi)(B)] | 2.4544599 |
N2O Emissions from Flares or Regenerators (mt N2O) [98.236(e)(1)(xvi)(C)] | 0.0003026 |
Were any dehydrator emissions vented to the atmosphere without being routed to a flare or regenerator firebox/fire tubes? [98.236(e)(1)(xvii)] | No |
Unit ID or Name [98.236(e)(1)(i)] | Haynesville - North Desoto -- NG Plant --- DE SOTO, LA (31) 230 - DehyC - Train2 (Central Processing Worksheet) |
Sub-Basin ID [98.236(e)(1)(xviii] | Not G&B |
Glycol dehydrator feed natural gas flow rate determined by engineering estimate based on best available data (MMscfd) [98.236(e)(1)(ii)] | 62.38 |
Dehydrator feed natural gas water content (pounds per MMscf) [98.236(e)(1)(iii)] | 28.69 |
Dehydrator outlet natural gas water content (pounds per MMscf) [98.236(e)(1)(iv)] | 1.29 |
Glycol dehydrator absorbent circulation pump type [98.236(e)(1)(v)] | Electric |
Dehydrator absorbent circulation rate (gallons per minute) [98.236(e)(1)(vi)] | 8 |
Report type of absorbent used [98.236(e)(1)(vii)] | Triethylene glycol (TEG) |
Report whether stripper gas is used in glycol dehydrator [98.236(e)(1)(viii)] | No |
Report whether a flash tank separator is used in glycol dehydrator [98.236(e)(1)(ix)] | Yes |
Total time the glycol dehydrator is operating (hours) [98.236(e)(1)(x)] | 6914 |
Temperature of the wet natural gas (°F) [98.236(e)(1)(xi)] | 76 |
Pressure of the wet natural gas (psig) [98.236(e)(1)(xii)] | 967 |
Concentration of CO2 in wet natural gas (mole fraction) [98.236(e)(1)(xiv)] | 0 |
Concentration of CH4 in wet natural gas (mole fraction) [98.236(e)(1)(xiii)] | 0.997 |
Were any dehydrator emissions vented to a vapor recovery device? [98.236(e)(1)(xv)] | No |
Were any dehydrator emissions vented to a flare or regenerator firebox/fire tubes? [98.236(e)(1)(xvi)] | Yes |
CO2 Emissions from Flares or Regenerators (mt CO2) [98.236(e)(1)(xvi)(A)] | 118.3334487 |
CH4 Emissions from Flares or Regenerators (mt CH4) [98.236(e)(1)(xvi)(B)] | 2.2440481 |
N2O Emissions from Flares or Regenerators (mt N2O) [98.236(e)(1)(xvi)(C)] | 0.0002767 |
Were any dehydrator emissions vented to the atmosphere without being routed to a flare or regenerator firebox/fire tubes? [98.236(e)(1)(xvii)] | No |
Unit ID or Name [98.236(e)(1)(i)] | Haynesville - North Desoto -- NG Plant --- DE SOTO, LA (31) 230 - DehyD - Train1 (Central Processing Worksheet) |
Sub-Basin ID [98.236(e)(1)(xviii] | Not G&B |
Glycol dehydrator feed natural gas flow rate determined by engineering estimate based on best available data (MMscfd) [98.236(e)(1)(ii)] | 65.85 |
Dehydrator feed natural gas water content (pounds per MMscf) [98.236(e)(1)(iii)] | 28.69 |
Dehydrator outlet natural gas water content (pounds per MMscf) [98.236(e)(1)(iv)] | 1.26 |
Glycol dehydrator absorbent circulation pump type [98.236(e)(1)(v)] | Electric |
Dehydrator absorbent circulation rate (gallons per minute) [98.236(e)(1)(vi)] | 9 |
Report type of absorbent used [98.236(e)(1)(vii)] | Triethylene glycol (TEG) |
Report whether stripper gas is used in glycol dehydrator [98.236(e)(1)(viii)] | No |
Report whether a flash tank separator is used in glycol dehydrator [98.236(e)(1)(ix)] | Yes |
Total time the glycol dehydrator is operating (hours) [98.236(e)(1)(x)] | 6536 |
Temperature of the wet natural gas (°F) [98.236(e)(1)(xi)] | 76 |
Pressure of the wet natural gas (psig) [98.236(e)(1)(xii)] | 967 |
Concentration of CO2 in wet natural gas (mole fraction) [98.236(e)(1)(xiv)] | 0 |
Concentration of CH4 in wet natural gas (mole fraction) [98.236(e)(1)(xiii)] | 0.997 |
Were any dehydrator emissions vented to a vapor recovery device? [98.236(e)(1)(xv)] | No |
Were any dehydrator emissions vented to a flare or regenerator firebox/fire tubes? [98.236(e)(1)(xvi)] | Yes |
CO2 Emissions from Flares or Regenerators (mt CO2) [98.236(e)(1)(xvi)(A)] | 126.0100406 |
CH4 Emissions from Flares or Regenerators (mt CH4) [98.236(e)(1)(xvi)(B)] | 2.3895658 |
N2O Emissions from Flares or Regenerators (mt N2O) [98.236(e)(1)(xvi)(C)] | 0.0002946 |
Were any dehydrator emissions vented to the atmosphere without being routed to a flare or regenerator firebox/fire tubes? [98.236(e)(1)(xvii)] | No |
Unique name or ID for reciprocating compressor [98.236(p)(1)(i)] | MC3554 |
Total time in operating-mode (hours) [98.236(p)(1)(ii)] | 7691 |
Total time in standby-pressurized-mode (hours) [98.236(p)(1)(iii)] | 1053 |
Total time in not-operating-depressurized-mode (hours) [98.236(p)(1)(iv)] | 16 |
Compressor measured in operating-mode? [98.236(p)(1)(v)] | Yes |
Compressor measured in standby-pressurized-mode? [98.236(p)(1)(vi)] | No |
Compressor measured in not-operating-depressurized-mode? [98.236(p)(1)(vii)] | No |
Compressor had blind flanges installed? [98.236(p)(1)(xii)] | No |
Power output of compressor driver (hp) [98.236(p)(1)(xiii)] | 1775 |
Compressor had scheduled depressurized shutdown during reporting year? [98.236(p)(1)(xiv)] | Yes |
Unique name or ID for reciprocating compressor [98.236(p)(1)(i)] | MC3555 |
Total time in operating-mode (hours) [98.236(p)(1)(ii)] | 6822 |
Total time in standby-pressurized-mode (hours) [98.236(p)(1)(iii)] | 1878 |
Total time in not-operating-depressurized-mode (hours) [98.236(p)(1)(iv)] | 60 |
Compressor measured in operating-mode? [98.236(p)(1)(v)] | Yes |
Compressor measured in standby-pressurized-mode? [98.236(p)(1)(vi)] | No |
Compressor measured in not-operating-depressurized-mode? [98.236(p)(1)(vii)] | No |
Compressor had blind flanges installed? [98.236(p)(1)(xii)] | No |
Power output of compressor driver (hp) [98.236(p)(1)(xiii)] | 1775 |
Compressor had scheduled depressurized shutdown during reporting year? [98.236(p)(1)(xiv)] | Yes |
Unique name or ID for reciprocating compressor [98.236(p)(1)(i)] | MC3556 |
Total time in operating-mode (hours) [98.236(p)(1)(ii)] | 2022 |
Total time in standby-pressurized-mode (hours) [98.236(p)(1)(iii)] | 6734 |
Total time in not-operating-depressurized-mode (hours) [98.236(p)(1)(iv)] | 4 |
Compressor measured in operating-mode? [98.236(p)(1)(v)] | No |
Compressor measured in standby-pressurized-mode? [98.236(p)(1)(vi)] | No |
Compressor measured in not-operating-depressurized-mode? [98.236(p)(1)(vii)] | Yes |
Compressor had blind flanges installed? [98.236(p)(1)(xii)] | No |
Power output of compressor driver (hp) [98.236(p)(1)(xiii)] | 1775 |
Compressor had scheduled depressurized shutdown during reporting year? [98.236(p)(1)(xiv)] | Yes |
Unique name or ID for reciprocating compressor [98.236(p)(1)(i)] | MC3557 |
Total time in operating-mode (hours) [98.236(p)(1)(ii)] | 6765 |
Total time in standby-pressurized-mode (hours) [98.236(p)(1)(iii)] | 1931 |
Total time in not-operating-depressurized-mode (hours) [98.236(p)(1)(iv)] | 64 |
Compressor measured in operating-mode? [98.236(p)(1)(v)] | Yes |
Compressor measured in standby-pressurized-mode? [98.236(p)(1)(vi)] | No |
Compressor measured in not-operating-depressurized-mode? [98.236(p)(1)(vii)] | No |
Compressor had blind flanges installed? [98.236(p)(1)(xii)] | No |
Power output of compressor driver (hp) [98.236(p)(1)(xiii)] | 1775 |
Compressor had scheduled depressurized shutdown during reporting year? [98.236(p)(1)(xiv)] | Yes |
Unique name or ID for reciprocating compressor [98.236(p)(1)(i)] | MC3558 |
Total time in operating-mode (hours) [98.236(p)(1)(ii)] | 6971 |
Total time in standby-pressurized-mode (hours) [98.236(p)(1)(iii)] | 1773 |
Total time in not-operating-depressurized-mode (hours) [98.236(p)(1)(iv)] | 16 |
Compressor measured in operating-mode? [98.236(p)(1)(v)] | Yes |
Compressor measured in standby-pressurized-mode? [98.236(p)(1)(vi)] | No |
Compressor measured in not-operating-depressurized-mode? [98.236(p)(1)(vii)] | No |
Compressor had blind flanges installed? [98.236(p)(1)(xii)] | No |
Power output of compressor driver (hp) [98.236(p)(1)(xiii)] | 1775 |
Compressor had scheduled depressurized shutdown during reporting year? [98.236(p)(1)(xiv)] | Yes |
Unique name or ID for reciprocating compressor [98.236(p)(1)(i)] | MC3559 |
Total time in operating-mode (hours) [98.236(p)(1)(ii)] | 7587 |
Total time in standby-pressurized-mode (hours) [98.236(p)(1)(iii)] | 1109 |
Total time in not-operating-depressurized-mode (hours) [98.236(p)(1)(iv)] | 64 |
Compressor measured in operating-mode? [98.236(p)(1)(v)] | Yes |
Compressor measured in standby-pressurized-mode? [98.236(p)(1)(vi)] | No |
Compressor measured in not-operating-depressurized-mode? [98.236(p)(1)(vii)] | No |
Compressor had blind flanges installed? [98.236(p)(1)(xii)] | No |
Power output of compressor driver (hp) [98.236(p)(1)(xiii)] | 1775 |
Compressor had scheduled depressurized shutdown during reporting year? [98.236(p)(1)(xiv)] | Yes |
Unique name or ID for reciprocating compressor [98.236(p)(1)(i)] | MC3560 |
Total time in operating-mode (hours) [98.236(p)(1)(ii)] | 3293 |
Total time in standby-pressurized-mode (hours) [98.236(p)(1)(iii)] | 5455 |
Total time in not-operating-depressurized-mode (hours) [98.236(p)(1)(iv)] | 12 |
Compressor measured in operating-mode? [98.236(p)(1)(v)] | No |
Compressor measured in standby-pressurized-mode? [98.236(p)(1)(vi)] | No |
Compressor measured in not-operating-depressurized-mode? [98.236(p)(1)(vii)] | Yes |
Compressor had blind flanges installed? [98.236(p)(1)(xii)] | No |
Power output of compressor driver (hp) [98.236(p)(1)(xiii)] | 1775 |
Compressor had scheduled depressurized shutdown during reporting year? [98.236(p)(1)(xiv)] | Yes |
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)] | MC3554 |
Reciprocating compressor source [98.236(p)(2)(i)(B)] | Blowdown valve |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | MC3554 BDV |
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)] | MC3554 |
Reciprocating compressor source [98.236(p)(2)(i)(B)] | Isolation valve |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | MC3554 ISO |
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)] | MC3554 |
Reciprocating compressor source [98.236(p)(2)(i)(B)] | Rod packing |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | MC3554 RPV |
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)] | MC3555 |
Reciprocating compressor source [98.236(p)(2)(i)(B)] | Blowdown valve |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | MC3555 BDV |
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)] | MC3555 |
Reciprocating compressor source [98.236(p)(2)(i)(B)] | Isolation valve |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | MC3555 ISO |
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)] | MC3555 |
Reciprocating compressor source [98.236(p)(2)(i)(B)] | Rod packing |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | MC3555 RPV |
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)] | MC3556 |
Reciprocating compressor source [98.236(p)(2)(i)(B)] | Blowdown valve |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | MC3556 BDV |
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)] | MC3556 |
Reciprocating compressor source [98.236(p)(2)(i)(B)] | Isolation valve |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | MC3556 ISO |
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)] | MC3556 |
Reciprocating compressor source [98.236(p)(2)(i)(B)] | Rod packing |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | MC3556 RPV |
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)] | MC3557 |
Reciprocating compressor source [98.236(p)(2)(i)(B)] | Blowdown valve |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | MC3557 BDV |
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)] | MC3557 |
Reciprocating compressor source [98.236(p)(2)(i)(B)] | Isolation valve |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | MC3557 ISO |
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)] | MC3557 |
Reciprocating compressor source [98.236(p)(2)(i)(B)] | Rod packing |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | MC3557 RPV |
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)] | MC3558 |
Reciprocating compressor source [98.236(p)(2)(i)(B)] | Blowdown valve |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | MC3558 BDV |
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)] | MC3558 |
Reciprocating compressor source [98.236(p)(2)(i)(B)] | Isolation valve |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | MC3558 ISO |
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)] | MC3558 |
Reciprocating compressor source [98.236(p)(2)(i)(B)] | Rod packing |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | MC3558 RPV |
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)] | MC3559 |
Reciprocating compressor source [98.236(p)(2)(i)(B)] | Blowdown valve |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | MC3559 BDV |
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)] | MC3559 |
Reciprocating compressor source [98.236(p)(2)(i)(B)] | Isolation valve |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | MC3559 ISO |
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)] | MC3559 |
Reciprocating compressor source [98.236(p)(2)(i)(B)] | Rod packing |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | MC3559 RPV |
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)] | MC3560 |
Reciprocating compressor source [98.236(p)(2)(i)(B)] | Blowdown valve |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | MC3560 BDV |
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)] | MC3560 |
Reciprocating compressor source [98.236(p)(2)(i)(B)] | Isolation valve |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | MC3560 ISO |
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)] | MC3560 |
Reciprocating compressor source [98.236(p)(2)(i)(B)] | Rod packing |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | MC3560 RPV |
Unique Name or ID for leak or vent (Specify) [98.236(p)(2)(i)(C)] [98.236(p)(3)(i)(A)] | MC3554 BDV |
Measurement date (mm/dd/yyyy) [98.236(p)(3)(i)(B)] | 2020-08-05 |
Measurement method [98.236(p)(3)(i)(C)] | Screening/Optical gas imaging |
Measured flow rate (standard cubic feet/hour) [98.236(p)(3)(i)(D)] | 0 |
Is the measurement location prior to or after commingling with non-compressor emission sources? [98.236(p)(3)(i)(F)] | Not manifolded |
Compressors in “Operating mode” | MC3554 |
Unique Name or ID for leak or vent (Specify) [98.236(p)(2)(i)(C)] [98.236(p)(3)(i)(A)] | MC3554 RPV |
Measurement date (mm/dd/yyyy) [98.236(p)(3)(i)(B)] | 2020-08-05 |
Measurement method [98.236(p)(3)(i)(C)] | High volume sampler |
Measured flow rate (standard cubic feet/hour) [98.236(p)(3)(i)(D)] | 139.704 |
Is the measurement location prior to or after commingling with non-compressor emission sources? [98.236(p)(3)(i)(F)] | Not manifolded |
Compressors in “Operating mode” | MC3554 |
Unique Name or ID for leak or vent (Specify) [98.236(p)(2)(i)(C)] [98.236(p)(3)(i)(A)] | MC3555 BDV |
Measurement date (mm/dd/yyyy) [98.236(p)(3)(i)(B)] | 2020-08-05 |
Measurement method [98.236(p)(3)(i)(C)] | Screening/Optical gas imaging |
Measured flow rate (standard cubic feet/hour) [98.236(p)(3)(i)(D)] | 0 |
Is the measurement location prior to or after commingling with non-compressor emission sources? [98.236(p)(3)(i)(F)] | Not manifolded |
Compressors in “Operating mode” | MC3555 |
Unique Name or ID for leak or vent (Specify) [98.236(p)(2)(i)(C)] [98.236(p)(3)(i)(A)] | MC3555 RPV |
Measurement date (mm/dd/yyyy) [98.236(p)(3)(i)(B)] | 2020-08-05 |
Measurement method [98.236(p)(3)(i)(C)] | High volume sampler |
Measured flow rate (standard cubic feet/hour) [98.236(p)(3)(i)(D)] | 69.852 |
Is the measurement location prior to or after commingling with non-compressor emission sources? [98.236(p)(3)(i)(F)] | Not manifolded |
Compressors in “Operating mode” | MC3555 |
Unique Name or ID for leak or vent (Specify) [98.236(p)(2)(i)(C)] [98.236(p)(3)(i)(A)] | MC3556 ISO |
Measurement date (mm/dd/yyyy) [98.236(p)(3)(i)(B)] | 2020-08-05 |
Measurement method [98.236(p)(3)(i)(C)] | Screening/Optical gas imaging |
Measured flow rate (standard cubic feet/hour) [98.236(p)(3)(i)(D)] | 0 |
Is the measurement location prior to or after commingling with non-compressor emission sources? [98.236(p)(3)(i)(F)] | Not manifolded |
Compressors in “Not-operating mode” | MC3556 |
Unique Name or ID for leak or vent (Specify) [98.236(p)(2)(i)(C)] [98.236(p)(3)(i)(A)] | MC3557 BDV |
Measurement date (mm/dd/yyyy) [98.236(p)(3)(i)(B)] | 2020-08-05 |
Measurement method [98.236(p)(3)(i)(C)] | Screening/Optical gas imaging |
Measured flow rate (standard cubic feet/hour) [98.236(p)(3)(i)(D)] | 0 |
Is the measurement location prior to or after commingling with non-compressor emission sources? [98.236(p)(3)(i)(F)] | Not manifolded |
Compressors in “Operating mode” | MC3557 |
Unique Name or ID for leak or vent (Specify) [98.236(p)(2)(i)(C)] [98.236(p)(3)(i)(A)] | MC3557 RPV |
Measurement date (mm/dd/yyyy) [98.236(p)(3)(i)(B)] | 2020-08-05 |
Measurement method [98.236(p)(3)(i)(C)] | High volume sampler |
Measured flow rate (standard cubic feet/hour) [98.236(p)(3)(i)(D)] | 202.989 |
Is the measurement location prior to or after commingling with non-compressor emission sources? [98.236(p)(3)(i)(F)] | Not manifolded |
Compressors in “Operating mode” | MC3557 |
Unique Name or ID for leak or vent (Specify) [98.236(p)(2)(i)(C)] [98.236(p)(3)(i)(A)] | MC3558 BDV |
Measurement date (mm/dd/yyyy) [98.236(p)(3)(i)(B)] | 2020-08-05 |
Measurement method [98.236(p)(3)(i)(C)] | High volume sampler |
Measured flow rate (standard cubic feet/hour) [98.236(p)(3)(i)(D)] | 11.941 |
Is the measurement location prior to or after commingling with non-compressor emission sources? [98.236(p)(3)(i)(F)] | Not manifolded |
Compressors in “Operating mode” | MC3558 |
Unique Name or ID for leak or vent (Specify) [98.236(p)(2)(i)(C)] [98.236(p)(3)(i)(A)] | MC3558 RPV |
Measurement date (mm/dd/yyyy) [98.236(p)(3)(i)(B)] | 2020-08-05 |
Measurement method [98.236(p)(3)(i)(C)] | High volume sampler |
Measured flow rate (standard cubic feet/hour) [98.236(p)(3)(i)(D)] | 171.346 |
Is the measurement location prior to or after commingling with non-compressor emission sources? [98.236(p)(3)(i)(F)] | Not manifolded |
Compressors in “Operating mode” | MC3558 |
Unique Name or ID for leak or vent (Specify) [98.236(p)(2)(i)(C)] [98.236(p)(3)(i)(A)] | MC3559 BDV |
Measurement date (mm/dd/yyyy) [98.236(p)(3)(i)(B)] | 2020-08-05 |
Measurement method [98.236(p)(3)(i)(C)] | Screening/Optical gas imaging |
Measured flow rate (standard cubic feet/hour) [98.236(p)(3)(i)(D)] | 0 |
Is the measurement location prior to or after commingling with non-compressor emission sources? [98.236(p)(3)(i)(F)] | Not manifolded |
Compressors in “Operating mode” | MC3559 |
Unique Name or ID for leak or vent (Specify) [98.236(p)(2)(i)(C)] [98.236(p)(3)(i)(A)] | MC3559 RPV |
Measurement date (mm/dd/yyyy) [98.236(p)(3)(i)(B)] | 2020-08-05 |
Measurement method [98.236(p)(3)(i)(C)] | High volume sampler |
Measured flow rate (standard cubic feet/hour) [98.236(p)(3)(i)(D)] | 139.107 |
Is the measurement location prior to or after commingling with non-compressor emission sources? [98.236(p)(3)(i)(F)] | Not manifolded |
Compressors in “Operating mode” | MC3559 |
Unique Name or ID for leak or vent (Specify) [98.236(p)(2)(i)(C)] [98.236(p)(3)(i)(A)] | MC3560 ISO |
Measurement date (mm/dd/yyyy) [98.236(p)(3)(i)(B)] | 2020-08-05 |
Measurement method [98.236(p)(3)(i)(C)] | High volume sampler |
Measured flow rate (standard cubic feet/hour) [98.236(p)(3)(i)(D)] | 177.914 |
Is the measurement location prior to or after commingling with non-compressor emission sources? [98.236(p)(3)(i)(F)] | Not manifolded |
Compressors in “Not-operating mode” | MC3560 |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | MC3554 BDV |
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)] | Single |
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)] | Atmosphere |
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)] | Yes |
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)] | No |
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)] | 0.0007021 |
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)] | 0.0132053 |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | MC3554 ISO |
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)] | Single |
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)] | Atmosphere |
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)] | No |
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)] | No |
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)] | 0.0002594 |
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)] | 0.0048789 |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | MC3554 RPV |
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)] | Single |
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)] | Atmosphere |
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)] | Yes |
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)] | No |
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)] | 1.0738188 |
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)] | 20.1973 |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | MC3555 BDV |
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)] | Single |
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)] | Atmosphere |
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)] | Yes |
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)] | No |
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)] | 0.0012521 |
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)] | 0.0235514 |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | MC3555 ISO |
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)] | Single |
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)] | Atmosphere |
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)] | No |
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)] | No |
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)] | 0.0009727 |
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)] | 0.018296 |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | MC3555 RPV |
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)] | Single |
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)] | Atmosphere |
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)] | Yes |
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)] | No |
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)] | 0.4762444 |
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)] | 8.9576115 |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | MC3556 BDV |
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)] | Single |
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)] | Atmosphere |
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)] | No |
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)] | No |
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)] | 0.0389859 |
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)] | 0.733281 |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | MC3556 ISO |
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)] | Single |
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)] | Atmosphere |
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)] | Yes |
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)] | No |
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)] | 0 |
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)] | 0 |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | MC3556 RPV |
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)] | Single |
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)] | Atmosphere |
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)] | No |
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)] | No |
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)] | 0.3864375 |
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)] | 7.2684467 |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | MC3557 BDV |
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)] | Single |
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)] | Atmosphere |
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)] | Yes |
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)] | No |
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)] | 0.0012875 |
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)] | 0.024216 |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | MC3557 ISO |
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)] | Single |
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)] | Atmosphere |
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)] | No |
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)] | No |
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)] | 0.0010376 |
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)] | 0.0195158 |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | MC3557 RPV |
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)] | Single |
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)] | Atmosphere |
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)] | Yes |
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)] | No |
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)] | 1.3723967 |
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)] | 25.8132073 |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | MC3558 BDV |
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)] | Single |
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)] | Atmosphere |
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)] | Yes |
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)] | No |
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)] | 0.0843729 |
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)] | 1.5869575 |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | MC3558 ISO |
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)] | Single |
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)] | Atmosphere |
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)] | No |
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)] | No |
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)] | 0.0002594 |
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)] | 0.0048789 |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | MC3558 RPV |
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)] | Single |
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)] | Atmosphere |
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)] | Yes |
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)] | No |
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)] | 1.1937363 |
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)] | 22.4528109 |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | MC3559 BDV |
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)] | Single |
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)] | Atmosphere |
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)] | Yes |
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)] | No |
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)] | 0.0007394 |
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)] | 0.0139076 |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | MC3559 ISO |
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)] | Single |
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)] | Atmosphere |
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)] | No |
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)] | No |
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)] | 0.0010376 |
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)] | 0.0195158 |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | MC3559 RPV |
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)] | Single |
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)] | Atmosphere |
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)] | Yes |
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)] | No |
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)] | 1.0547716 |
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)] | 19.8390437 |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | MC3560 BDV |
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)] | Single |
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)] | Atmosphere |
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)] | No |
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)] | No |
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)] | 0.0598169 |
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)] | 1.125088 |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | MC3560 ISO |
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)] | Single |
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)] | Atmosphere |
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)] | Yes |
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)] | No |
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)] | 0.0021337 |
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)] | 0.0401322 |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | MC3560 RPV |
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)] | Single |
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)] | Atmosphere |
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)] | No |
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)] | No |
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)] | 0.6293466 |
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)] | 11.8372873 |
Component Type [98.236(q)(2)(i)] | Compressor Components, Gas Service - Valve |
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)] | 0 |
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)] | 0 |
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)] | 0 |
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)] | 0 |
Component Type [98.236(q)(2)(i)] | Compressor Components, Gas Service - Connector |
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)] | 0 |
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)] | 0 |
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)] | 0 |
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)] | 0 |
Component Type [98.236(q)(2)(i)] | Compressor Components, Gas Service - Open-ended Line |
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)] | 0 |
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)] | 0 |
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)] | 0 |
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)] | 0 |
Component Type [98.236(q)(2)(i)] | Compressor Components, Gas Service - Pressure Relief Valve |
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)] | 0 |
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)] | 0 |
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)] | 0 |
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)] | 0 |
Component Type [98.236(q)(2)(i)] | Compressor Components, Gas Service - Meter |
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)] | 0 |
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)] | 0 |
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)] | 0 |
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)] | 0 |
Component Type [98.236(q)(2)(i)] | Non-Compressor Components, Gas Service - Valve |
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)] | 1 |
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)] | 8784 |
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)] | 0.1050065 |
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)] | 1.0420395 |
Component Type [98.236(q)(2)(i)] | Non-Compressor Components, Gas Service - Connector |
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)] | 4 |
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)] | 8784 |
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)] | 0.3735747 |
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)] | 3.7071936 |
Component Type [98.236(q)(2)(i)] | Non-Compressor Components, Gas Service - Open-ended Line |
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)] | 0 |
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)] | 0 |
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)] | 0 |
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)] | 0 |
Component Type [98.236(q)(2)(i)] | Non-Compressor components, Gas Service - Pressure Relief Valve |
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)] | 0 |
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)] | 0 |
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)] | 0 |
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)] | 0 |
Component Type [98.236(q)(2)(i)] | Non-Compressor components, Gas Service - Meter |
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)] | 1 |
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)] | 8784 |
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)] | 0.0479235 |
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)] | 0.4755726 |