Facility Name:HOLCIM (US) INC. DEVIL'S SLIDE PLANT
Facility Identifier:
Facility Reporting Year:2020
Facility Location:
Address: 6055 EAST CROYDON ROAD
City: MORGAN
State: UT
Postal Code: 84050

Facility Site Details:
CO2 equivalent emissions from facility subparts C-II, SS, and TT (metric tons):690,197.9
CO2 equivalent emissions from supplier subparts LL-QQ (metric tons):
Biogenic CO2 emissions from facility subparts C-II, SS, and TT (metric tons):0
Cogeneration Unit Emissions Indicator:N
GHG Report Start Date:2020-01-01
GHG Report End Date:2020-12-31
Description of Changes to Calculation Methodology:
Plant Code Indicator:N
Primary NAICS Code:327310
Second Primary NAICS Code:

Parent Company Details:
Parent Company Name:HOLCIM PARTICIPATIONS (US) INC
Address:8700 W. Bryn Mawr Ave., Suite 300N, Chicago,  IL 60631
Percent Ownership Interest:100

Subpart C: General Stationary Fuel Combustion

Gas Information Details

Gas NameCarbon Dioxide
Gas Quantity2,698.2 (Metric Tons)
Own Result?

Gas NameBiogenic Carbon dioxide
Gas Quantity0 (Metric Tons)
Own Result?

Gas NameMethane
Gas Quantity0.05 (Metric Tons)
Own Result?

Gas NameNitrous Oxide
Gas Quantity0.005 (Metric Tons)
Own Result?

Unit Details:
Unit Name : GP-Non Kiln Unit
Unit Type : OCS (Other combustion source)
Unit Description :
Other Unit Name :
Small Unit Aggregation Details:
Use Ivt Indicator: Y
Highest Maximum Rated Heat Input Capacity: 0.88
Cumulative Maximum Rated Heat Input Capacity:

Emission Details:
Annual CO2 mass emissions from sorbent: 0 (Metric Tons)
Annual Biogenic CO2 Emissions: 0 (metric tons)
Annual Fossil fuel based CO2 Emissions: 2698.2 (metric tons)

Tier Fuel Details:
Fuel : Natural Gas (Weighted U.S. Average)
Tier Name : Tier 1 (Equation C-1b, natural gas billing in mmBtu)
Tier Methodology Start Date : 2020-01-01
Tier Methodology End Date : 2020-12-31

Fuel Emission Details :
Total CO2 emissionsTotal CH4 emissionsTotal N2O emissionsTotal CH4 emissions CO2eTotal N2O emissions CO2e
2698.2 (Metric Tons) 0.05 (Metric Tons) 0.005 (Metric Tons) 1.3 (Metric Tons) 1.5 (Metric Tons)



Subpart H: Cement Production


CEMS Monitoring Location (CML) Details

CML Name : Main Stack
Description :
Configuration Type : Process/stationary combustion units share common stack
Types of Fuel Combusted : Coal, Tires, Plastics and Natural Gas

Tier 4 Methodology Information
Methodology Start Date : 2020-01-01
Methodology End Date : 2020-12-31

Quarterly CO2 Emissions
First Quarter : 139429 (metric tons)
Second Quarter : 190916 (metric tons)
Third Quarter : 159162 (metric tons)
Fourth Quarter : 195077 (metric tons)

Annual CO2 Emissions
Total annual CO2 mass emissions (biogenic and non-biogenic) measured by the CEMS: 684584 (metric tons)
Emissions reported for the CEMS include emissions calculated according to 98.33(a)(4)(viii) for a slipstream that bypassed the CEMS. :
Total annual biogenic CO2 : 0 (metric tons)
Total annual non-biogenic CO2 : 684584 (metric tons)

Equation C-10 Summary and Results
Total CH4 : 45 (metric tons)
Total N2O : 6 (metric tons)

Additional Emissions Information
Total source operating hours in the reporting year8129 (hours)
Total Operating hours in which a substitute data value was used in the emissions calculations for CO2 concentration67 (hours)
Total Operating hours in which a substitute data value was used in the emissions calculations for stack gas flow rate27 (hours)
Total Operating hours in which a substitute data value was used in the emissions calculations for stack gas moisture content (hours)

Process Units:

Unit Name : DS Kiln #1

Gas Information Details

Gas NameCarbon Dioxide
Gas Quantity684,584 (Metric Tons)
Own Result?

Gas NameBiogenic Carbon dioxide
Gas Quantity0 (Metric Tons)
Own Result?

Gas NameMethane
Gas Quantity45 (Metric Tons)
Own Result?

Gas NameNitrous Oxide
Gas Quantity6 (Metric Tons)
Own Result?

Summary Information for the facility:

Number Of Kilns1
Number Of Operating Kilns1
Annual cement production for the facility()
Annual clinker production()
Annual average clinker CO2 emissions factor across all kilns()
Annual average CKD CO2 emissions factor across all kilns()

No Cems Cement Kiln Details:
Cems Cement Kiln Details:
Kiln Name : DS Kiln #1
Kiln Type : Cement Kiln
Kiln Description :

Monthly Inputs/Outputs:
Month Name
January
Clinker Production ()
Clinker Production IndicatorN
February
Clinker Production ()
Clinker Production IndicatorN
March
Clinker Production ()
Clinker Production IndicatorN
April
Clinker Production ()
Clinker Production IndicatorN
May
Clinker Production ()
Clinker Production IndicatorN
June
Clinker Production ()
Clinker Production IndicatorN
July
Clinker Production ()
Clinker Production IndicatorN
August
Clinker Production ()
Clinker Production IndicatorN
September
Clinker Production ()
Clinker Production IndicatorN
October
Clinker Production ()
Clinker Production IndicatorN
November
Clinker Production ()
Clinker Production IndicatorN
December
Clinker Production ()
Clinker Production IndicatorN