Facility Name:Targa Midstream Services LLC - Sandhills Gas Plant
Facility Identifier:
Facility Reporting Year:2020
Facility Location:
Address: 5880 FM 1233
City: Crane
State: TX
Postal Code: 79731

Facility Site Details:
CO2 equivalent emissions from facility subparts C-II, SS, and TT (metric tons):222,258.18
CO2 equivalent emissions from supplier subparts LL-QQ (metric tons):
Biogenic CO2 emissions from facility subparts C-II, SS, and TT (metric tons):0
Cogeneration Unit Emissions Indicator:N
GHG Report Start Date:2020-01-01
GHG Report End Date:2020-12-31
Description of Changes to Calculation Methodology:
Plant Code Indicator:N
Primary NAICS Code:211130
Second Primary NAICS Code:

Parent Company Details:
Parent Company Name:TARGA RESOURCES CORP
Address:811 Louisiana Street, Suite 2100, Houston,  TX 77002
Percent Ownership Interest:100

Subpart C: General Stationary Fuel Combustion

Gas Information Details

Gas NameCarbon Dioxide
Gas Quantity93,959.1786 (Metric Tons)
Own Result?

Gas NameBiogenic Carbon dioxide
Gas Quantity0 (Metric Tons)
Own Result?

Gas NameMethane
Gas Quantity1.77081 (Metric Tons)
Own Result?

Gas NameNitrous Oxide
Gas Quantity0.177081 (Metric Tons)
Own Result?

Unit Details:
Unit Name : CP-plant master
Unit Type : OCS (Other combustion source)
Unit Description :
Other Unit Name :
Common Pipe Details:
Use Ivt Indicator: N
Maximum Rated Heat Input Capacity: 49.8
Cumulative Maximum Rated Heat Input Capacity: 232.2

Emission Details:
Annual CO2 mass emissions from sorbent: 0 (Metric Tons)
Annual Biogenic CO2 Emissions: 0 (metric tons)
Annual Fossil fuel based CO2 Emissions: 93959.1786 (metric tons)

Tier Fuel Details:
Fuel : Natural Gas (Weighted U.S. Average)
Tier Name : Tier 2 (Equation C-2a)
Tier Methodology Start Date : 2020-01-01
Tier Methodology End Date : 2020-12-31
Frequency of HHV determinations : Monthly

Tier 2 Monthly HHV Details :
JanuaryFebruaryMarchAprilMayJuneJulyAugustSeptemberOctoberNovemberDecember
N N N N N N N N N N N N

Fuel Emission Details :
Total CO2 emissionsTotal CH4 emissionsTotal N2O emissionsTotal CH4 emissions CO2eTotal N2O emissions CO2e
93959.1786 (Metric Tons) 1.77081 (Metric Tons) 0.177081 (Metric Tons) 44.27025 (Metric Tons) 52.770138 (Metric Tons)

Equation C2a/C9a Inputs :
Fuel Quantity : 1762000000 ()
Use Default High Heat Value : false
Equation C2b Inputs :
Fuel CombustedHigh Heat Value
January146833333.333333 ()0.001005 ()
February146833333.333333 ()0.001005 ()
March146833333.333333 ()0.001005 ()
April146833333.333333 ()0.001005 ()
May146833333.333333 ()0.001005 ()
June146833333.333333 ()0.001005 ()
July146833333.333333 ()0.001005 ()
August146833333.333333 ()0.001005 ()
September146833333.333333 ()0.001005 ()
October146833333.333333 ()0.001005 ()
November146833333.333333 ()0.001005 ()
December146833333.333333 ()0.001005 ()


Subpart W: Petroleum and Natural Gas Systems

Gas Information Details

Gas NameCarbon Dioxide
Gas Quantity113,006.855538 (Metric Tons)
Own Result?

Gas NameMethane
Gas Quantity606.187417 (Metric Tons)
Own Result?

Gas NameNitrous Oxide
Gas Quantity0.13565 (Metric Tons)
Own Result?


SubpartWSummaryDetails:
Industry Segment Number3
Industry Segment NameOnshore natural gas processing [98.230(a)(3)]
Total Reported CO2 Emissions (mt CO2)113006.855538493
Total CO2e Emissions (mt CO2e)128201.964692662
Total Reported CH4 Emissions (mt CH4)606.187416814582
Total Reported N2O Emissions (mt N2O)0.135650113438


SubpartWSourceReportingFormRowDetails:
Source Reporting FormOnshore Production [98.236(aa)(1)]
Required for Selected Industry SegmentNo
Source Reporting FormFacility Overview [98.236(aa)(2-11)]
Required for Selected Industry SegmentYes
Source Reporting FormNatural Gas Pneumatic Devices [98.236(b)]
Required for Selected Industry SegmentNo
Total Reported CO2 Emissions (mt CO2)0
Total Reported CH4 Emissions (mt CH4)0
Source Reporting FormNatural Gas Driven Pneumatic Pumps [98.236(c)]
Required for Selected Industry SegmentNo
Total Reported CO2 Emissions (mt CO2)0
Total Reported CH4 Emissions (mt CH4)0
Source Reporting FormAcid Gas Removal Units [98.236(d)]
Required for Selected Industry SegmentYes
Total Reported CO2 Emissions (mt CO2)40110.45087052
Source Reporting FormDehydrators [98.236(e)]
Required for Selected Industry SegmentYes
Total Reported CO2 Emissions (mt CO2)0.703895156208094
Total Reported CH4 Emissions (mt CH4)0.11153618596896
Total Reported N2O Emissions (mt N2O)0
Source Reporting FormWell Venting for Liquids Unloading [98.236(f)]
Required for Selected Industry SegmentNo
Total Reported CO2 Emissions (mt CO2)0
Total Reported CH4 Emissions (mt CH4)0
Source Reporting FormCompletions and Workovers with Hydraulic Fracturing [98.236(g)]
Required for Selected Industry SegmentNo
Total Reported CO2 Emissions (mt CO2)0
Total Reported CH4 Emissions (mt CH4)0
Total Reported N2O Emissions (mt N2O)0
Source Reporting FormCompletions and Workovers without Hydraulic Fracturing [98.236(h)]
Required for Selected Industry SegmentNo
Total Reported CO2 Emissions (mt CO2)0
Total Reported CH4 Emissions (mt CH4)0
Total Reported N2O Emissions (mt N2O)0
Source Reporting FormBlowdown Vent Stacks [98.236(i)]
Required for Selected Industry SegmentYes
Total Reported CO2 Emissions (mt CO2)0.00588216073680052
Total Reported CH4 Emissions (mt CH4)3.98697883136415
Source Reporting FormAtmospheric Storage Tanks [98.236(j)]
Required for Selected Industry SegmentNo
Total Reported CO2 Emissions (mt CO2)0
Total Reported CH4 Emissions (mt CH4)0
Total Reported N2O Emissions (mt N2O)0
Source Reporting FormTransmission Storage Tanks [98.236(k)]
Required for Selected Industry SegmentNo
Total Reported CO2 Emissions (mt CO2)0
Total Reported CH4 Emissions (mt CH4)0
Total Reported N2O Emissions (mt N2O)0
Source Reporting FormWell Testing [98.236(l)]
Required for Selected Industry SegmentNo
Total Reported CO2 Emissions (mt CO2)0
Total Reported CH4 Emissions (mt CH4)0
Total Reported N2O Emissions (mt N2O)0
Source Reporting FormAssociated Gas Venting and Flaring [98.236(m)]
Required for Selected Industry SegmentNo
Total Reported CO2 Emissions (mt CO2)0
Total Reported CH4 Emissions (mt CH4)0
Total Reported N2O Emissions (mt N2O)0
Source Reporting FormFlare Stacks [98.236(n)]
Required for Selected Industry SegmentYes
Total Reported CO2 Emissions (mt CO2)72891.1814319219
Total Reported CH4 Emissions (mt CH4)412.292717231431
Total Reported N2O Emissions (mt N2O)0.135650113438
Source Reporting FormCentrifugal Compressors [98.236(o)]
Required for Selected Industry SegmentYes
Total Reported CO2 Emissions (mt CO2)0.004453305287412
Total Reported CH4 Emissions (mt CH4)18.624339723744
Source Reporting FormReciprocating Compressors [98.236(p)]
Required for Selected Industry SegmentYes
Total Reported CO2 Emissions (mt CO2)3.93715747690664
Total Reported CH4 Emissions (mt CH4)146.66502368777
Source Reporting FormEquipment Leaks Surveys and Population Counts [98.236(q,r)]
Required for Selected Industry SegmentYes
Total Reported CO2 Emissions (mt CO2)0.571847952389184
Total Reported CH4 Emissions (mt CH4)24.506821154304
Source Reporting FormOffshore Petroleum and Natural Gas Production [98.236(s)]
Required for Selected Industry SegmentNo
Total Reported CO2 Emissions (mt CO2)0
Total Reported CH4 Emissions (mt CH4)0
Total Reported N2O Emissions (mt N2O)0
Source Reporting FormEnhanced Oil Recovery Injection Pumps [98.236(w)]
Required for Selected Industry SegmentNo
Total Reported CO2 Emissions (mt CO2)0
Source Reporting FormEnhanced Oil Recovery Hydrocarbon Liquids [98.236(x)]
Required for Selected Industry SegmentNo
Total Reported CO2 Emissions (mt CO2)0
Source Reporting FormCombustion Equipment at Onshore Petroleum and Natural Gas Production Facilities, Onshore Petroleum and Natural Gas Gathering and Boosting Facilities, and Natural gas Distribution Facilities [98.236(z)]
Required for Selected Industry SegmentNo
Total Reported CO2 Emissions (mt CO2)0
Total Reported CH4 Emissions (mt CH4)0
Total Reported N2O Emissions (mt N2O)0


FacilityOverviewDetails:


FacilityOverviewNaturalGasProcessingRowDetails:
Average mole fraction of CH4 in natural gas received [98.236(aa)(3)(v)]0.7605
Average mole fraction of CO2 in natural gas received [98.236(aa)(3)(vi)]0.018526
Does the facility fractionate NGLs? [98.236(aa)(3)(vii)]No


AcidGasRemovalUnitsDetails:
mt CO240110.45087052
Did the Facility have any acid gas removal units that vent directly to the atmosphere, to a flare or engine, or to a sulfur recovery plant subject to reporting under 98.232 [98.236(d)]?Yes
Were missing data procedures used for any parameters to calculate GHG emissions? [98.235]No


AcidGasInfoRowDetails:
Unit ID or Name [98.236(d)(1)(i)]AMN_Amine Treater Routed to Flare
Total feed rate entering the acid gas removal unit for the year (million cubic feet) [98.236(d)(1)(ii)]45693
Calculation Method Used (Select from list) [98.236(d)(1)(iii)]Calculation Methodology 2 [98.233(d)(2)]
Are any CO2 emissions from the acid gas removal unit recovered and transferred outside the facility? (Yes / No) [98.236(d)(1)(iv)]Yes
Total CO2 Emissions (mt CO2) [98.236(d)(1)(v)]40110.45087052


AcidGasCalcMethod2EmissionsRowDetails:
Unit ID or Name [98.236(d)(1)(i)]AMN_Amine Treater Routed to Flare
Annual average fraction of CO2 content in the vent from the acid gas removal unit, VolCO2 (volumetric fraction) [98.236(d)(2)(i)(A)]0.6178
Annual volume of gas vented from the acid gas removal unit, Vs (actual or standard cubic feet) [98.236(d)(2)(i)(B)]1234309000
Annual volume of gas vented reported on an Actual or Standard basis? [98.236]Standard
Temperature used to calculate volume of gas vented (°F) [98.236]60
Pressure used to calculate volume of gas vented (psi) [98.236]14.7


DehydratorsDetails:
mt CO20.703895156208094
mt CH40.11153618596896
mt N2O0
Did the facility have any glycol dehydrators with annual average daily natural gas throughputs greater than or equal to 0.4MMscfd subject to reporting under 98.232 [98.236(e)]?Yes
Did the facility have any glycol dehydrators with annual average daily natural gas throughputs less than 0.4MMscfd subject to reporting under 98.232 [98.236(e)]?No
Did the facility have any desiccant dehydrators subject to reporting under 98.232 [98.236(e)]?Yes
Were missing data procedures used for any parameters to calculate GHG emissions? [98.235]No


SmallGlycolDehydrators:
Emissions vented to flare or regenerator firebox/fire tubes
Emissions that were not vented to a flare or regenerator firebox/fire tubes


DessicantDehydrators:
Total Number of Desiccant Dehydrators [98.236(e)(3)(i)]3
Vapor RecoveryNo
Dehydrator vents to flares or regenerator firebox/fire tubesNo
Control devices other than vapor recovery, flare or regenerator firebox/fire tubesNo
Emissions vented to flare or regenerator firebox/fire tubes
Emissions that were not vented to a flare or regenerator firebox/fire tubes
Total CO2 Emissions (mt CO2) [98.236(e)(3)(i)] [98.236(e)(3)(ii)]0.00017949020809356
Total CH4 Emissions (mt CH4) [98.236(e)(3)(i)] [98.236(e)(3)(iii)]0.00268951396896


GlycolDehydratorsMoreThanSpecifiedValueRowDetails:
Unit ID or Name [98.236(e)(1)(i)]DEHY_Sandhills H-07 DEHY
Glycol dehydrator feed natural gas flow rate determined by engineering estimate based on best available data (MMscfd) [98.236(e)(1)(ii)]124.84
Dehydrator feed natural gas water content (pounds per MMscf) [98.236(e)(1)(iii)]89.05
Dehydrator outlet natural gas water content (pounds per MMscf) [98.236(e)(1)(iv)]7
Glycol dehydrator absorbent circulation pump type [98.236(e)(1)(v)]Electric
Dehydrator absorbent circulation rate (gallons per minute) [98.236(e)(1)(vi)]11
Report type of absorbent used [98.236(e)(1)(vii)]Triethylene glycol (TEG)
Report whether stripper gas is used in glycol dehydrator [98.236(e)(1)(viii)]No
Report whether a flash tank separator is used in glycol dehydrator [98.236(e)(1)(ix)]Yes
Total time the glycol dehydrator is operating (hours) [98.236(e)(1)(x)]8784
Temperature of the wet natural gas (°F) [98.236(e)(1)(xi)]105
Pressure of the wet natural gas (psig) [98.236(e)(1)(xii)]45
Concentration of CO2 in wet natural gas (mole fraction) [98.236(e)(1)(xiv)]0.018526
Concentration of CH4 in wet natural gas (mole fraction) [98.236(e)(1)(xiii)]0.7605
Were any dehydrator emissions vented to a vapor recovery device? [98.236(e)(1)(xv)]Yes
Were any dehydrator emissions vented to a flare or regenerator firebox/fire tubes? [98.236(e)(1)(xvi)]No
Were any dehydrator emissions vented to the atmosphere without being routed to a flare or regenerator firebox/fire tubes? [98.236(e)(1)(xvii)]Yes
CO2 Emissions from Venting (mt CO2) [98.236(e)(1)(xvii)(A)]0.703715666
CH4 Emissions from Venting (mt CH4) [98.236(e)(1)(xvii)(B)]0.108846672


BlowdownVentStacksDetails:
mt CO20.00588216073680052
mt CH43.98697883136415
Did the facility have any blowdown vent stacks subject to reporting under 98.232 [98.236(i)]?Yes
Were missing data procedures used for any parameters to calculate GHG emissions? [98.235]No
How were emissions determined? [98.236(i)]Calculated by equipment or event type


BlowdownEquipmentOrEventEmissionsRowDetails:
Equipment or event type [98.236(i)(1)] [98.236(i)(2)]All other equipment with a physical volume greater than or equal 50 cubic feet
Total number of blowdowns for equipment or event type, N [98.236(i)(1)(i)]3
Annual total CO2 emissions for each equipment or event type (mt CO2) [98.236(i)(1)(ii)]0.000899580670027819
Annual total CH4 emissions for each equipment or event type (mt CH4) [98.236(i)(1)(iii)]0.0240372243920318
Equipment or event type [98.236(i)(1)] [98.236(i)(2)]Compressors
Total number of blowdowns for equipment or event type, N [98.236(i)(1)(i)]79
Annual total CO2 emissions for each equipment or event type (mt CO2) [98.236(i)(1)(ii)]0.0049825800667727
Annual total CH4 emissions for each equipment or event type (mt CH4) [98.236(i)(1)(iii)]3.96294160697212


FlareStacksDetails:
mt CO272891.1814319219
mt CH4412.292717231431
mt N2O0.135650113438
Did the facility have flare stacks subject to reporting under 98.232 [98.236(n)]?Yes
Were missing data procedures used for any parameters to calculate GHG emissions? [98.235]No


UniqueFlareStacksRowDetails:
Unique Name or ID Number for the Flare Stack [98.236(n)(1)]FLARE_F-1 (inlet)
Does the flare stack have a continuous flow monitor on gas to the flare? [98.236(n)(2)]Yes
Does the flare stack have a continuous gas analyzer on gas to the flare? [98.236(n)(3)]No
Were CEMS used to measure CO2 emissions for the flare stack? [98.233(n)(8)] [98.236(n)(12)]No
Volume of gas sent to flare, Vs (standard cubic feet) [98.236(n)(4)]496222000
Flare combustion efficiency (decimal value) [98.236(n)(6)]0.98
Mole fraction of CH4 in flare feed gas, XCH4 [98.236(n)(7)]0.7605
Mole fraction of CO2 in flare feed gas, XCO2 [98.236(n)(8)]0.018526
Fraction of feed gas sent to un-lit flare, Zu [98.236(n)(5)]0
CO2 emissions (mt CO2) [98.236(n)(9)]31672.4452489241
CH4 Emissions (mt CH4) (Eq. W-19) [98.236(n)(10)]139.542284029232
N2O Emissions (mt N2O) (Eq. W-40) [98.236(n)(11)]0.058063928664
Unique Name or ID Number for the Flare Stack [98.236(n)(1)]FLARE_F-2 (residue)
Does the flare stack have a continuous flow monitor on gas to the flare? [98.236(n)(2)]Yes
Does the flare stack have a continuous gas analyzer on gas to the flare? [98.236(n)(3)]No
Were CEMS used to measure CO2 emissions for the flare stack? [98.233(n)(8)] [98.236(n)(12)]No
Volume of gas sent to flare, Vs (standard cubic feet) [98.236(n)(4)]784063000
Flare combustion efficiency (decimal value) [98.236(n)(6)]0.98
Mole fraction of CH4 in flare feed gas, XCH4 [98.236(n)(7)]0.9395
Mole fraction of CO2 in flare feed gas, XCO2 [98.236(n)(8)]0.00008
Fraction of feed gas sent to un-lit flare, Zu [98.236(n)(5)]0
CO2 emissions (mt CO2) [98.236(n)(9)]39808.2522951351
CH4 Emissions (mt CH4) (Eq. W-19) [98.236(n)(10)]272.381958608693
N2O Emissions (mt N2O) (Eq. W-40) [98.236(n)(11)]0.07722236487
Unique Name or ID Number for the Flare Stack [98.236(n)(1)]FLARE_F-4 (acid)
Does the flare stack have a continuous flow monitor on gas to the flare? [98.236(n)(2)]Yes
Does the flare stack have a continuous gas analyzer on gas to the flare? [98.236(n)(3)]No
Were CEMS used to measure CO2 emissions for the flare stack? [98.233(n)(8)] [98.236(n)(12)]No
Volume of gas sent to flare, Vs (standard cubic feet) [98.236(n)(4)]97696000
Flare combustion efficiency (decimal value) [98.236(n)(6)]0.98
Mole fraction of CH4 in flare feed gas, XCH4 [98.236(n)(7)]0.0102
Mole fraction of CO2 in flare feed gas, XCO2 [98.236(n)(8)]0.6178
Fraction of feed gas sent to un-lit flare, Zu [98.236(n)(5)]0
CO2 emissions (mt CO2) [98.236(n)(9)]1410.48388786267
CH4 Emissions (mt CH4) (Eq. W-19) [98.236(n)(10)]0.368474593505987
N2O Emissions (mt N2O) (Eq. W-40) [98.236(n)(11)]0.000363819904


CentrifugalCompressorsDetails:
mt CO20.004453305287412
mt CH418.624339723744
Did the facility have any centrifugal compressors subject to reporting under 98.232 [98.236(o)]?Yes
Were missing data procedures used for any parameters to calculate GHG emissions? [98.235]No


CentrifugalCompressorsActivityDataRowDetails:
Compressor ID or Unique Name [98.236(o)(1)(i)]CENTR_JLS C-2 (TURBINE)
Total time in operating-mode (hours) [98.236(o)(1)(ii)]3273
Total time in not-operating-depressurized-mode (hours) [98.236(o)(1)(iii)]5511
Compressor measured in operating-mode? [98.236(o)(1)(iv)]No
Compressor measured in not-operating-depressurized-mode? [98.236(o)(1)(v)]Yes
Compressor had blind flanges installed? [98.236(o)(1)(x)]No
Seal Type (wet or dry) [98.236(o)(1)(xi)]Dry
Power output of compressor driver (hp) [98.236(o)(1)(xiii)]1153
Compressor had scheduled depressurized shutdown during reporting year? [98.236(o)(1)(xiv)]Yes
Compressor ID or Unique Name [98.236(o)(1)(i)]CENTR_JLS C-3 (TURBINE)
Total time in operating-mode (hours) [98.236(o)(1)(ii)]4687
Total time in not-operating-depressurized-mode (hours) [98.236(o)(1)(iii)]4097
Compressor measured in operating-mode? [98.236(o)(1)(iv)]No
Compressor measured in not-operating-depressurized-mode? [98.236(o)(1)(v)]Yes
Compressor had blind flanges installed? [98.236(o)(1)(x)]No
Seal Type (wet or dry) [98.236(o)(1)(xi)]Dry
Power output of compressor driver (hp) [98.236(o)(1)(xiii)]1153
Compressor had scheduled depressurized shutdown during reporting year? [98.236(o)(1)(xiv)]Yes


CentrifugalCompressorsCompressorSourceRowDetails:
Unique Compressor Name or ID [98.236(o)(2)(i)(A)]CENTR_JLS C-2 (TURBINE)
Centrifugal compressor source [98.236(o)(2)(i)(B)]Blowdown valve
Unique Name or ID for leak or vent [98.236(o)(2)(i)(C)]CENTR_JLS C-2 (TURBINE).Blowdown valve
Unique Compressor Name or ID [98.236(o)(2)(i)(A)]CENTR_JLS C-2 (TURBINE)
Centrifugal compressor source [98.236(o)(2)(i)(B)]Isolation valve
Unique Name or ID for leak or vent [98.236(o)(2)(i)(C)]CENTR_JLS C-2 (TURBINE).Isolation valve
Unique Compressor Name or ID [98.236(o)(2)(i)(A)]CENTR_JLS C-3 (TURBINE)
Centrifugal compressor source [98.236(o)(2)(i)(B)]Blowdown valve
Unique Name or ID for leak or vent [98.236(o)(2)(i)(C)]CENTR_JLS C-3 (TURBINE).Blowdown valve
Unique Compressor Name or ID [98.236(o)(2)(i)(A)]CENTR_JLS C-3 (TURBINE)
Centrifugal compressor source [98.236(o)(2)(i)(B)]Isolation valve
Unique Name or ID for leak or vent [98.236(o)(2)(i)(C)]CENTR_JLS C-3 (TURBINE).Isolation valve


CentrifugalCompressorsLeakOrVentSampleDataRowDetails:
Unique Name or ID for leak or vent (Specify) [98.236(o)(3)(i)(A)]CENTR_JLS C-2 (TURBINE).Isolation valve
Measurement date (mm/dd/yyyy) [98.236(o)(3)(i)(B)]2020-09-23
Measurement method [98.236(o)(3)(i)(C)]Screening/Optical gas imaging
Measured flow rate, MTs,m, MTs,g,avg (standard cubic feet/hour) [98.236(o)(3)(i)(D)]0
Is the measurement location prior to or after commingling with non-compressor emission sources? [98.236(o)(3)(i)(F)]Not manifolded
Compressors in “Not-operating mode”CENTR_JLS C-2 (TURBINE)
Unique Name or ID for leak or vent (Specify) [98.236(o)(3)(i)(A)]CENTR_JLS C-3 (TURBINE).Isolation valve
Measurement date (mm/dd/yyyy) [98.236(o)(3)(i)(B)]2020-09-23
Measurement method [98.236(o)(3)(i)(C)]High volume sampler
Measured flow rate, MTs,m, MTs,g,avg (standard cubic feet/hour) [98.236(o)(3)(i)(D)]88.03
Is the measurement location prior to or after commingling with non-compressor emission sources? [98.236(o)(3)(i)(F)]Not manifolded
Compressors in “Not-operating mode”CENTR_JLS C-3 (TURBINE)


CentrifugalCompressorsEmissionFactorsSampleDataRowDetails:
Compressor Mode [98.236(o)(3)(ii)(A)]Operating
Compressor Source [98.236(o)(3)(ii)(A)]Wet seal
Compressor mode-source combination reporter emission factor, EFs,m (standard cubic feet per hour) [98.236(o)(3)(ii)(B)]118.8155714
Total number of compressors measured in the compressor mode-source combination in current reporting year and preceding two reporting years [98.236(o)(3)(ii)(C)]14
Is the reporter emission factor facility-specific or based on all of the reporter's applicable facilities? [98.236(o)(3)(ii)(D)]All applicable facilities
Compressor Mode [98.236(o)(3)(ii)(A)]Operating
Compressor Source [98.236(o)(3)(ii)(A)]Blowdown valve
Compressor mode-source combination reporter emission factor, EFs,m (standard cubic feet per hour) [98.236(o)(3)(ii)(B)]84.4
Total number of compressors measured in the compressor mode-source combination in current reporting year and preceding two reporting years [98.236(o)(3)(ii)(C)]3
Is the reporter emission factor facility-specific or based on all of the reporter's applicable facilities? [98.236(o)(3)(ii)(D)]All applicable facilities
Compressor Mode [98.236(o)(3)(ii)(A)]Not-operating
Compressor Source [98.236(o)(3)(ii)(A)]Isolation valve
Compressor mode-source combination reporter emission factor, EFs,m (standard cubic feet per hour) [98.236(o)(3)(ii)(B)]22.0075
Total number of compressors measured in the compressor mode-source combination in current reporting year and preceding two reporting years [98.236(o)(3)(ii)(C)]4
Is the reporter emission factor facility-specific or based on all of the reporter's applicable facilities? [98.236(o)(3)(ii)(D)]All applicable facilities


CentrifugalCompressorsLeakOrVentDataRowDetails:
Unique Name or ID for leak or vent [98.236(o)(2)(i)(C)]CENTR_JLS C-2 (TURBINE).Blowdown valve
Leak or vent for a single compressor source or a manifolded group? [98.236(o)(2)(ii)(A)] [98.236(o)(1)(vi)]Single
Where are leak or vent emissions released? [98.236(o)(2)(ii)(A)] [98.236(o)(1)(vii) through (ix)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(o)(2)(ii)(B)]No
Were continuous measurements conducted on the leak or vent? [98.236(o)(2)(ii)(C)]No
CO2 emissions vented to atmosphere (mt CO2) [98.236(o)(2)(ii)(D)(1)]0.00119148354384
CH4 emissions vented to atmosphere (mt CH4) [98.236(o)(2)(ii)(D)(2)]4.98294926208
Unique Name or ID for leak or vent [98.236(o)(2)(i)(C)]CENTR_JLS C-2 (TURBINE).Isolation valve
Leak or vent for a single compressor source or a manifolded group? [98.236(o)(2)(ii)(A)] [98.236(o)(1)(vi)]Single
Where are leak or vent emissions released? [98.236(o)(2)(ii)(A)] [98.236(o)(1)(vii) through (ix)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(o)(2)(ii)(B)]Yes
Were continuous measurements conducted on the leak or vent? [98.236(o)(2)(ii)(C)]No
CO2 emissions vented to atmosphere (mt CO2) [98.236(o)(2)(ii)(D)(1)]0
CH4 emissions vented to atmosphere (mt CH4) [98.236(o)(2)(ii)(D)(2)]0
Unique Name or ID for leak or vent [98.236(o)(2)(i)(C)]CENTR_JLS C-3 (TURBINE).Blowdown valve
Leak or vent for a single compressor source or a manifolded group? [98.236(o)(2)(ii)(A)] [98.236(o)(1)(vi)]Single
Where are leak or vent emissions released? [98.236(o)(2)(ii)(A)] [98.236(o)(1)(vii) through (ix)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(o)(2)(ii)(B)]No
Were continuous measurements conducted on the leak or vent? [98.236(o)(2)(ii)(C)]No
CO2 emissions vented to atmosphere (mt CO2) [98.236(o)(2)(ii)(D)(1)]0.00170622773296
CH4 emissions vented to atmosphere (mt CH4) [98.236(o)(2)(ii)(D)(2)]7.13568077952
Unique Name or ID for leak or vent [98.236(o)(2)(i)(C)]CENTR_JLS C-3 (TURBINE).Isolation valve
Leak or vent for a single compressor source or a manifolded group? [98.236(o)(2)(ii)(A)] [98.236(o)(1)(vi)]Single
Where are leak or vent emissions released? [98.236(o)(2)(ii)(A)] [98.236(o)(1)(vii) through (ix)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(o)(2)(ii)(B)]Yes
Were continuous measurements conducted on the leak or vent? [98.236(o)(2)(ii)(C)]No
CO2 emissions vented to atmosphere (mt CO2) [98.236(o)(2)(ii)(D)(1)]0.001555594010612
CH4 emissions vented to atmosphere (mt CH4) [98.236(o)(2)(ii)(D)(2)]6.505709682144


ReciprocatingCompressorsDetails:
mt CO23.93715747690664
mt CH4146.66502368777
Did the facility have any reciprocating compressors subject to reporting under 98.232 [98.236(p)]?Yes
Were missing data procedures used for any parameters to calculate GHG emissions? [98.235]No


ReciprocatingCompressorsActivityDataRowDetails:
Unique name or ID for reciprocating compressor [98.236(p)(1)(i)]RECIP_C-09
Total time in operating-mode (hours) [98.236(p)(1)(ii)]7806
Total time in standby-pressurized-mode (hours) [98.236(p)(1)(iii)]538.8
Total time in not-operating-depressurized-mode (hours) [98.236(p)(1)(iv)]439.2
Compressor measured in operating-mode? [98.236(p)(1)(v)]Yes
Compressor measured in standby-pressurized-mode? [98.236(p)(1)(vi)]No
Compressor measured in not-operating-depressurized-mode? [98.236(p)(1)(vii)]No
Compressor had blind flanges installed? [98.236(p)(1)(xii)]No
Power output of compressor driver (hp) [98.236(p)(1)(xiii)]1200
Compressor had scheduled depressurized shutdown during reporting year? [98.236(p)(1)(xiv)]Yes
Unique name or ID for reciprocating compressor [98.236(p)(1)(i)]RECIP_C-10
Total time in operating-mode (hours) [98.236(p)(1)(ii)]8166
Total time in standby-pressurized-mode (hours) [98.236(p)(1)(iii)]454.7
Total time in not-operating-depressurized-mode (hours) [98.236(p)(1)(iv)]163.3
Compressor measured in operating-mode? [98.236(p)(1)(v)]No
Compressor measured in standby-pressurized-mode? [98.236(p)(1)(vi)]No
Compressor measured in not-operating-depressurized-mode? [98.236(p)(1)(vii)]No
Compressor had blind flanges installed? [98.236(p)(1)(xii)]No
Power output of compressor driver (hp) [98.236(p)(1)(xiii)]1200
Compressor had scheduled depressurized shutdown during reporting year? [98.236(p)(1)(xiv)]Yes
Unique name or ID for reciprocating compressor [98.236(p)(1)(i)]RECIP_C-11
Total time in operating-mode (hours) [98.236(p)(1)(ii)]8478
Total time in standby-pressurized-mode (hours) [98.236(p)(1)(iii)]130.3
Total time in not-operating-depressurized-mode (hours) [98.236(p)(1)(iv)]175.7
Compressor measured in operating-mode? [98.236(p)(1)(v)]Yes
Compressor measured in standby-pressurized-mode? [98.236(p)(1)(vi)]No
Compressor measured in not-operating-depressurized-mode? [98.236(p)(1)(vii)]No
Compressor had blind flanges installed? [98.236(p)(1)(xii)]No
Power output of compressor driver (hp) [98.236(p)(1)(xiii)]1200
Compressor had scheduled depressurized shutdown during reporting year? [98.236(p)(1)(xiv)]Yes
Unique name or ID for reciprocating compressor [98.236(p)(1)(i)]RECIP_C-12
Total time in operating-mode (hours) [98.236(p)(1)(ii)]8454
Total time in standby-pressurized-mode (hours) [98.236(p)(1)(iii)]66.5
Total time in not-operating-depressurized-mode (hours) [98.236(p)(1)(iv)]263.5
Compressor measured in operating-mode? [98.236(p)(1)(v)]Yes
Compressor measured in standby-pressurized-mode? [98.236(p)(1)(vi)]No
Compressor measured in not-operating-depressurized-mode? [98.236(p)(1)(vii)]No
Compressor had blind flanges installed? [98.236(p)(1)(xii)]No
Power output of compressor driver (hp) [98.236(p)(1)(xiii)]1200
Compressor had scheduled depressurized shutdown during reporting year? [98.236(p)(1)(xiv)]Yes
Unique name or ID for reciprocating compressor [98.236(p)(1)(i)]RECIP_C-13
Total time in operating-mode (hours) [98.236(p)(1)(ii)]7086
Total time in standby-pressurized-mode (hours) [98.236(p)(1)(iii)]1258.8
Total time in not-operating-depressurized-mode (hours) [98.236(p)(1)(iv)]439.2
Compressor measured in operating-mode? [98.236(p)(1)(v)]No
Compressor measured in standby-pressurized-mode? [98.236(p)(1)(vi)]No
Compressor measured in not-operating-depressurized-mode? [98.236(p)(1)(vii)]Yes
Compressor had blind flanges installed? [98.236(p)(1)(xii)]No
Power output of compressor driver (hp) [98.236(p)(1)(xiii)]1200
Compressor had scheduled depressurized shutdown during reporting year? [98.236(p)(1)(xiv)]Yes
Unique name or ID for reciprocating compressor [98.236(p)(1)(i)]RECIP_C-14
Total time in operating-mode (hours) [98.236(p)(1)(ii)]8499
Total time in standby-pressurized-mode (hours) [98.236(p)(1)(iii)]0
Total time in not-operating-depressurized-mode (hours) [98.236(p)(1)(iv)]285
Compressor measured in operating-mode? [98.236(p)(1)(v)]Yes
Compressor measured in standby-pressurized-mode? [98.236(p)(1)(vi)]No
Compressor measured in not-operating-depressurized-mode? [98.236(p)(1)(vii)]No
Compressor had blind flanges installed? [98.236(p)(1)(xii)]No
Power output of compressor driver (hp) [98.236(p)(1)(xiii)]1300
Compressor had scheduled depressurized shutdown during reporting year? [98.236(p)(1)(xiv)]Yes
Unique name or ID for reciprocating compressor [98.236(p)(1)(i)]RECIP_JLS C-4 (ENG)
Total time in operating-mode (hours) [98.236(p)(1)(ii)]8248
Total time in standby-pressurized-mode (hours) [98.236(p)(1)(iii)]360.3
Total time in not-operating-depressurized-mode (hours) [98.236(p)(1)(iv)]175.7
Compressor measured in operating-mode? [98.236(p)(1)(v)]Yes
Compressor measured in standby-pressurized-mode? [98.236(p)(1)(vi)]No
Compressor measured in not-operating-depressurized-mode? [98.236(p)(1)(vii)]No
Compressor had blind flanges installed? [98.236(p)(1)(xii)]No
Power output of compressor driver (hp) [98.236(p)(1)(xiii)]1668
Compressor had scheduled depressurized shutdown during reporting year? [98.236(p)(1)(xiv)]Yes
Unique name or ID for reciprocating compressor [98.236(p)(1)(i)]RECIP_JLS C-5 (ENG)
Total time in operating-mode (hours) [98.236(p)(1)(ii)]4246
Total time in standby-pressurized-mode (hours) [98.236(p)(1)(iii)]2342
Total time in not-operating-depressurized-mode (hours) [98.236(p)(1)(iv)]2196
Compressor measured in operating-mode? [98.236(p)(1)(v)]Yes
Compressor measured in standby-pressurized-mode? [98.236(p)(1)(vi)]No
Compressor measured in not-operating-depressurized-mode? [98.236(p)(1)(vii)]No
Compressor had blind flanges installed? [98.236(p)(1)(xii)]No
Power output of compressor driver (hp) [98.236(p)(1)(xiii)]1232
Compressor had scheduled depressurized shutdown during reporting year? [98.236(p)(1)(xiv)]Yes
Unique name or ID for reciprocating compressor [98.236(p)(1)(i)]RECIP_JLS C-6
Total time in operating-mode (hours) [98.236(p)(1)(ii)]6127
Total time in standby-pressurized-mode (hours) [98.236(p)(1)(iii)]900.2
Total time in not-operating-depressurized-mode (hours) [98.236(p)(1)(iv)]1756.8
Compressor measured in operating-mode? [98.236(p)(1)(v)]Yes
Compressor measured in standby-pressurized-mode? [98.236(p)(1)(vi)]No
Compressor measured in not-operating-depressurized-mode? [98.236(p)(1)(vii)]No
Compressor had blind flanges installed? [98.236(p)(1)(xii)]No
Power output of compressor driver (hp) [98.236(p)(1)(xiii)]1675
Compressor had scheduled depressurized shutdown during reporting year? [98.236(p)(1)(xiv)]Yes
Unique name or ID for reciprocating compressor [98.236(p)(1)(i)]RECIP_C-6 (30 MM Pre-compressor)
Total time in operating-mode (hours) [98.236(p)(1)(ii)]8566
Total time in standby-pressurized-mode (hours) [98.236(p)(1)(iii)]145.3
Total time in not-operating-depressurized-mode (hours) [98.236(p)(1)(iv)]72.7
Compressor measured in operating-mode? [98.236(p)(1)(v)]No
Compressor measured in standby-pressurized-mode? [98.236(p)(1)(vi)]No
Compressor measured in not-operating-depressurized-mode? [98.236(p)(1)(vii)]Yes
Compressor had blind flanges installed? [98.236(p)(1)(xii)]No
Power output of compressor driver (hp) [98.236(p)(1)(xiii)]350
Compressor had scheduled depressurized shutdown during reporting year? [98.236(p)(1)(xiv)]Yes
Unique name or ID for reciprocating compressor [98.236(p)(1)(i)]RECIP_JLS-7
Total time in operating-mode (hours) [98.236(p)(1)(ii)]6863
Total time in standby-pressurized-mode (hours) [98.236(p)(1)(iii)]640.3
Total time in not-operating-depressurized-mode (hours) [98.236(p)(1)(iv)]1280.7
Compressor measured in operating-mode? [98.236(p)(1)(v)]Yes
Compressor measured in standby-pressurized-mode? [98.236(p)(1)(vi)]No
Compressor measured in not-operating-depressurized-mode? [98.236(p)(1)(vii)]No
Compressor had blind flanges installed? [98.236(p)(1)(xii)]No
Power output of compressor driver (hp) [98.236(p)(1)(xiii)]1668
Compressor had scheduled depressurized shutdown during reporting year? [98.236(p)(1)(xiv)]Yes


ReciprocatingCompressorSourceRowDetails:
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]RECIP_C-09
Reciprocating compressor source [98.236(p)(2)(i)(B)]Blowdown valve
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_C-09.Blowdown valve
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]RECIP_C-09
Reciprocating compressor source [98.236(p)(2)(i)(B)]Isolation valve
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_C-09.Isolation valve
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]RECIP_C-09
Reciprocating compressor source [98.236(p)(2)(i)(B)]Rod packing
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_C-09.Rod packing
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]RECIP_C-10
Reciprocating compressor source [98.236(p)(2)(i)(B)]Blowdown valve
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_C-10.Blowdown valve
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]RECIP_C-10
Reciprocating compressor source [98.236(p)(2)(i)(B)]Isolation valve
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_C-10.Isolation valve
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]RECIP_C-10
Reciprocating compressor source [98.236(p)(2)(i)(B)]Rod packing
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_C-10.Rod packing
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]RECIP_C-11
Reciprocating compressor source [98.236(p)(2)(i)(B)]Blowdown valve
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_C-11.Blowdown valve
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]RECIP_C-11
Reciprocating compressor source [98.236(p)(2)(i)(B)]Isolation valve
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_C-11.Isolation valve
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]RECIP_C-11
Reciprocating compressor source [98.236(p)(2)(i)(B)]Rod packing
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_C-11.Rod packing
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]RECIP_C-12
Reciprocating compressor source [98.236(p)(2)(i)(B)]Blowdown valve
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_C-12.Blowdown valve
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]RECIP_C-12
Reciprocating compressor source [98.236(p)(2)(i)(B)]Isolation valve
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_C-12.Isolation valve
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]RECIP_C-12
Reciprocating compressor source [98.236(p)(2)(i)(B)]Rod packing
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_C-12.Rod packing
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]RECIP_C-13
Reciprocating compressor source [98.236(p)(2)(i)(B)]Blowdown valve
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_C-13.Blowdown valve
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]RECIP_C-13
Reciprocating compressor source [98.236(p)(2)(i)(B)]Isolation valve
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_C-13.Isolation valve
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]RECIP_C-13
Reciprocating compressor source [98.236(p)(2)(i)(B)]Rod packing
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_C-13.Rod packing
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]RECIP_C-14
Reciprocating compressor source [98.236(p)(2)(i)(B)]Blowdown valve
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_C-14.Blowdown valve
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]RECIP_C-14
Reciprocating compressor source [98.236(p)(2)(i)(B)]Isolation valve
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_C-14.Isolation valve
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]RECIP_C-14
Reciprocating compressor source [98.236(p)(2)(i)(B)]Rod packing
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_C-14.Rod packing
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]RECIP_JLS C-4 (ENG)
Reciprocating compressor source [98.236(p)(2)(i)(B)]Blowdown valve
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_JLS C-4 (ENG).Blowdown valve
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]RECIP_JLS C-4 (ENG)
Reciprocating compressor source [98.236(p)(2)(i)(B)]Isolation valve
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_JLS C-4 (ENG).Isolation valve
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]RECIP_JLS C-4 (ENG)
Reciprocating compressor source [98.236(p)(2)(i)(B)]Rod packing
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_JLS C-4 (ENG).Rod packing
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]RECIP_JLS C-5 (ENG)
Reciprocating compressor source [98.236(p)(2)(i)(B)]Blowdown valve
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_JLS C-5 (ENG).Blowdown valve
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]RECIP_JLS C-5 (ENG)
Reciprocating compressor source [98.236(p)(2)(i)(B)]Isolation valve
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_JLS C-5 (ENG).Isolation valve
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]RECIP_JLS C-5 (ENG)
Reciprocating compressor source [98.236(p)(2)(i)(B)]Rod packing
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_JLS C-5 (ENG).Rod packing
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]RECIP_JLS C-6
Reciprocating compressor source [98.236(p)(2)(i)(B)]Blowdown valve
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_JLS C-6.Blowdown valve
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]RECIP_JLS C-6
Reciprocating compressor source [98.236(p)(2)(i)(B)]Isolation valve
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_JLS C-6.Isolation valve
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]RECIP_JLS C-6
Reciprocating compressor source [98.236(p)(2)(i)(B)]Rod packing
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_JLS C-6.Rod packing
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]RECIP_C-6 (30 MM Pre-compressor)
Reciprocating compressor source [98.236(p)(2)(i)(B)]Blowdown valve
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_C-6 (30 MM Pre-compressor).Blowdown valve
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]RECIP_C-6 (30 MM Pre-compressor)
Reciprocating compressor source [98.236(p)(2)(i)(B)]Isolation valve
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_C-6 (30 MM Pre-compressor).Isolation valve
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]RECIP_C-6 (30 MM Pre-compressor)
Reciprocating compressor source [98.236(p)(2)(i)(B)]Rod packing
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_C-6 (30 MM Pre-compressor).Rod packing
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]RECIP_JLS-7
Reciprocating compressor source [98.236(p)(2)(i)(B)]Blowdown valve
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_JLS-7.Blowdown valve
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]RECIP_JLS-7
Reciprocating compressor source [98.236(p)(2)(i)(B)]Isolation valve
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_JLS-7.Isolation valve
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]RECIP_JLS-7
Reciprocating compressor source [98.236(p)(2)(i)(B)]Rod packing
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_JLS-7.Rod packing


ReciprocatingCompressorsLeakOrVentSampleDataRowDetails:
Unique Name or ID for leak or vent (Specify) [98.236(p)(2)(i)(C)] [98.236(p)(3)(i)(A)]RECIP_C-09.Rod packing
Measurement date (mm/dd/yyyy) [98.236(p)(3)(i)(B)]2020-09-23
Measurement method [98.236(p)(3)(i)(C)]High volume sampler
Measured flow rate (standard cubic feet/hour) [98.236(p)(3)(i)(D)]3.863
Is the measurement location prior to or after commingling with non-compressor emission sources? [98.236(p)(3)(i)(F)]Not manifolded
Compressors in “Operating mode”RECIP_C-09
Unique Name or ID for leak or vent (Specify) [98.236(p)(2)(i)(C)] [98.236(p)(3)(i)(A)]RECIP_C-11.Rod packing
Measurement date (mm/dd/yyyy) [98.236(p)(3)(i)(B)]2020-09-23
Measurement method [98.236(p)(3)(i)(C)]Screening/Optical gas imaging
Measured flow rate (standard cubic feet/hour) [98.236(p)(3)(i)(D)]0
Is the measurement location prior to or after commingling with non-compressor emission sources? [98.236(p)(3)(i)(F)]Not manifolded
Compressors in “Operating mode”RECIP_C-11
Unique Name or ID for leak or vent (Specify) [98.236(p)(2)(i)(C)] [98.236(p)(3)(i)(A)]RECIP_C-12.Rod packing
Measurement date (mm/dd/yyyy) [98.236(p)(3)(i)(B)]2020-09-23
Measurement method [98.236(p)(3)(i)(C)]Screening/Optical gas imaging
Measured flow rate (standard cubic feet/hour) [98.236(p)(3)(i)(D)]0
Is the measurement location prior to or after commingling with non-compressor emission sources? [98.236(p)(3)(i)(F)]Not manifolded
Compressors in “Operating mode”RECIP_C-12
Unique Name or ID for leak or vent (Specify) [98.236(p)(2)(i)(C)] [98.236(p)(3)(i)(A)]RECIP_C-13.Isolation valve
Measurement date (mm/dd/yyyy) [98.236(p)(3)(i)(B)]2020-09-23
Measurement method [98.236(p)(3)(i)(C)]Screening/Acoustic leak detection
Measured flow rate (standard cubic feet/hour) [98.236(p)(3)(i)(D)]0
Is the measurement location prior to or after commingling with non-compressor emission sources? [98.236(p)(3)(i)(F)]Not manifolded
Compressors in “Not-operating mode”RECIP_C-13
Unique Name or ID for leak or vent (Specify) [98.236(p)(2)(i)(C)] [98.236(p)(3)(i)(A)]RECIP_C-14.Rod packing
Measurement date (mm/dd/yyyy) [98.236(p)(3)(i)(B)]2020-09-23
Measurement method [98.236(p)(3)(i)(C)]Screening/Optical gas imaging
Measured flow rate (standard cubic feet/hour) [98.236(p)(3)(i)(D)]0
Is the measurement location prior to or after commingling with non-compressor emission sources? [98.236(p)(3)(i)(F)]Not manifolded
Compressors in “Operating mode”RECIP_C-14
Unique Name or ID for leak or vent (Specify) [98.236(p)(2)(i)(C)] [98.236(p)(3)(i)(A)]RECIP_JLS C-4 (ENG).Blowdown valve
Measurement date (mm/dd/yyyy) [98.236(p)(3)(i)(B)]2020-09-23
Measurement method [98.236(p)(3)(i)(C)]Screening/Optical gas imaging
Measured flow rate (standard cubic feet/hour) [98.236(p)(3)(i)(D)]0
Is the measurement location prior to or after commingling with non-compressor emission sources? [98.236(p)(3)(i)(F)]Not manifolded
Compressors in “Operating mode”RECIP_JLS C-4 (ENG)
Unique Name or ID for leak or vent (Specify) [98.236(p)(2)(i)(C)] [98.236(p)(3)(i)(A)]RECIP_JLS C-4 (ENG).Rod packing
Measurement date (mm/dd/yyyy) [98.236(p)(3)(i)(B)]2020-09-23
Measurement method [98.236(p)(3)(i)(C)]High volume sampler
Measured flow rate (standard cubic feet/hour) [98.236(p)(3)(i)(D)]131.48
Is the measurement location prior to or after commingling with non-compressor emission sources? [98.236(p)(3)(i)(F)]Not manifolded
Compressors in “Operating mode”RECIP_JLS C-4 (ENG)
Unique Name or ID for leak or vent (Specify) [98.236(p)(2)(i)(C)] [98.236(p)(3)(i)(A)]RECIP_JLS C-5 (ENG).Blowdown valve
Measurement date (mm/dd/yyyy) [98.236(p)(3)(i)(B)]2020-09-23
Measurement method [98.236(p)(3)(i)(C)]Screening/Optical gas imaging
Measured flow rate (standard cubic feet/hour) [98.236(p)(3)(i)(D)]0
Is the measurement location prior to or after commingling with non-compressor emission sources? [98.236(p)(3)(i)(F)]Not manifolded
Compressors in “Operating mode”RECIP_JLS C-5 (ENG)
Unique Name or ID for leak or vent (Specify) [98.236(p)(2)(i)(C)] [98.236(p)(3)(i)(A)]RECIP_JLS C-5 (ENG).Rod packing
Measurement date (mm/dd/yyyy) [98.236(p)(3)(i)(B)]2020-09-23
Measurement method [98.236(p)(3)(i)(C)]High volume sampler
Measured flow rate (standard cubic feet/hour) [98.236(p)(3)(i)(D)]423.782
Is the measurement location prior to or after commingling with non-compressor emission sources? [98.236(p)(3)(i)(F)]Not manifolded
Compressors in “Operating mode”RECIP_JLS C-5 (ENG)
Unique Name or ID for leak or vent (Specify) [98.236(p)(2)(i)(C)] [98.236(p)(3)(i)(A)]RECIP_JLS C-6.Blowdown valve
Measurement date (mm/dd/yyyy) [98.236(p)(3)(i)(B)]2020-09-23
Measurement method [98.236(p)(3)(i)(C)]Screening/Optical gas imaging
Measured flow rate (standard cubic feet/hour) [98.236(p)(3)(i)(D)]0
Is the measurement location prior to or after commingling with non-compressor emission sources? [98.236(p)(3)(i)(F)]Not manifolded
Compressors in “Operating mode”RECIP_JLS C-6
Unique Name or ID for leak or vent (Specify) [98.236(p)(2)(i)(C)] [98.236(p)(3)(i)(A)]RECIP_JLS C-6.Rod packing
Measurement date (mm/dd/yyyy) [98.236(p)(3)(i)(B)]2020-09-23
Measurement method [98.236(p)(3)(i)(C)]High volume sampler
Measured flow rate (standard cubic feet/hour) [98.236(p)(3)(i)(D)]79.565
Is the measurement location prior to or after commingling with non-compressor emission sources? [98.236(p)(3)(i)(F)]Not manifolded
Compressors in “Operating mode”RECIP_JLS C-6
Unique Name or ID for leak or vent (Specify) [98.236(p)(2)(i)(C)] [98.236(p)(3)(i)(A)]RECIP_C-6 (30 MM Pre-compressor).Isolation valve
Measurement date (mm/dd/yyyy) [98.236(p)(3)(i)(B)]2020-09-23
Measurement method [98.236(p)(3)(i)(C)]Screening/Optical gas imaging
Measured flow rate (standard cubic feet/hour) [98.236(p)(3)(i)(D)]0
Is the measurement location prior to or after commingling with non-compressor emission sources? [98.236(p)(3)(i)(F)]Not manifolded
Compressors in “Not-operating mode”RECIP_C-6 (30 MM Pre-compressor)
Unique Name or ID for leak or vent (Specify) [98.236(p)(2)(i)(C)] [98.236(p)(3)(i)(A)]RECIP_C-6 (30 MM Pre-compressor).Isolation valve
Measurement date (mm/dd/yyyy) [98.236(p)(3)(i)(B)]2020-09-24
Measurement method [98.236(p)(3)(i)(C)]Screening/Optical gas imaging
Measured flow rate (standard cubic feet/hour) [98.236(p)(3)(i)(D)]0
Is the measurement location prior to or after commingling with non-compressor emission sources? [98.236(p)(3)(i)(F)]Not manifolded
Compressors in “Not-operating mode”RECIP_C-6 (30 MM Pre-compressor)
Unique Name or ID for leak or vent (Specify) [98.236(p)(2)(i)(C)] [98.236(p)(3)(i)(A)]RECIP_JLS-7.Blowdown valve
Measurement date (mm/dd/yyyy) [98.236(p)(3)(i)(B)]2020-09-23
Measurement method [98.236(p)(3)(i)(C)]High volume sampler
Measured flow rate (standard cubic feet/hour) [98.236(p)(3)(i)(D)]41.193
Is the measurement location prior to or after commingling with non-compressor emission sources? [98.236(p)(3)(i)(F)]Not manifolded
Compressors in “Operating mode”RECIP_JLS-7
Unique Name or ID for leak or vent (Specify) [98.236(p)(2)(i)(C)] [98.236(p)(3)(i)(A)]RECIP_JLS-7.Rod packing
Measurement date (mm/dd/yyyy) [98.236(p)(3)(i)(B)]2020-09-23
Measurement method [98.236(p)(3)(i)(C)]High volume sampler
Measured flow rate (standard cubic feet/hour) [98.236(p)(3)(i)(D)]202.015
Is the measurement location prior to or after commingling with non-compressor emission sources? [98.236(p)(3)(i)(F)]Not manifolded
Compressors in “Operating mode”RECIP_JLS-7


ReciprocatingCompressorsEmissionFactorsSampleDataRowDetails:
Compressor Mode [98.236(p)(3)(ii)(A)]Operating
Compressor Source [98.236(p)(3)(ii)(A)]Blowdown valve
Compressor mode-source combination reporter emission factor, EFs,m (standard cubic feet per hour) [98.236(p)(3)(ii)(B)]10.90454369
Total number of compressors measured in the compressor mode-source combination in current reporting year and preceding two reporting years, Countm [98.236(p)(3)(ii)(C)]412
Is the reporter emission factor facility-specific or based on all of the reporter's applicable facilities? [98.236(p)(3)(ii)(D)]All applicable facilities
Compressor Mode [98.236(p)(3)(ii)(A)]Operating
Compressor Source [98.236(p)(3)(ii)(A)]Rod packing
Compressor mode-source combination reporter emission factor, EFs,m (standard cubic feet per hour) [98.236(p)(3)(ii)(B)]81.92604592
Total number of compressors measured in the compressor mode-source combination in current reporting year and preceding two reporting years, Countm [98.236(p)(3)(ii)(C)]588
Is the reporter emission factor facility-specific or based on all of the reporter's applicable facilities? [98.236(p)(3)(ii)(D)]All applicable facilities
Compressor Mode [98.236(p)(3)(ii)(A)]Standby-pressurized
Compressor Source [98.236(p)(3)(ii)(A)]Blowdown valve
Compressor mode-source combination reporter emission factor, EFs,m (standard cubic feet per hour) [98.236(p)(3)(ii)(B)]9.45780303
Total number of compressors measured in the compressor mode-source combination in current reporting year and preceding two reporting years, Countm [98.236(p)(3)(ii)(C)]132
Is the reporter emission factor facility-specific or based on all of the reporter's applicable facilities? [98.236(p)(3)(ii)(D)]All applicable facilities
Compressor Mode [98.236(p)(3)(ii)(A)]Not-operating-depressurized
Compressor Source [98.236(p)(3)(ii)(A)]Isolation valve
Compressor mode-source combination reporter emission factor, EFs,m (standard cubic feet per hour) [98.236(p)(3)(ii)(B)]96.14192818
Total number of compressors measured in the compressor mode-source combination in current reporting year and preceding two reporting years, Countm [98.236(p)(3)(ii)(C)]181
Is the reporter emission factor facility-specific or based on all of the reporter's applicable facilities? [98.236(p)(3)(ii)(D)]All applicable facilities


ReciprocatingCompressorsLeakOrVentDataRowDetails:
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_C-09.Blowdown valve
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]No
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)]0.000389122809828408
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)]1.62736550422163
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_C-09.Isolation valve
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]No
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)]0.000182127176943729
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)]0.761681087958303
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_C-09.Rod packing
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]Yes
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)]0.0001300627258296
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)]0.5439403397952
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_C-10.Blowdown valve
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Flare
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]No
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
Percentage of time the device was operational when compressor source emissions were routed to device [98.236(p)(2)(ii)(E)]98
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_C-10.Isolation valve
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Flare
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]No
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
Percentage of time the device was operational when compressor source emissions were routed to device [98.236(p)(2)(ii)(E)]98
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_C-10.Rod packing
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]No
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)]0.00288556569802667
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)]12.0678355483827
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_C-11.Blowdown valve
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]No
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)]0.000404065204661535
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)]1.68985666970385
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_C-11.Isolation valve
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]No
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)]0.00007
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)]0.304707120114467
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_C-11.Rod packing
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]Yes
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)]0
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)]0
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_C-12.Blowdown valve
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]No
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)]0.000400333782526636
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)]1.67425134534185
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_C-12.Isolation valve
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]No
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)]0.000109268012578945
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)]0.456973967843836
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_C-12.Rod packing
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]Yes
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)]0
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)]0
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_C-13.Blowdown valve
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]No
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)]0.000384629950921815
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)]1.60857574578227
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_C-13.Isolation valve
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]Yes
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)]0
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)]0
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_C-13.Rod packing
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]No
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)]0.00250393320306355
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)]10.4717955787215
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_C-14.Blowdown valve
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]No
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)]3.011681035586
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)]0.0181500040622854
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_C-14.Isolation valve
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]No
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)]0.890412680094994
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)]0.00536610403620979
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_C-14.Rod packing
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]Yes
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)]0
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)]0
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_JLS C-4 (ENG).Blowdown valve
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]Yes
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)]0.00001
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)]0.0614684893937396
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_JLS C-4 (ENG).Isolation valve
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]No
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)]0.00007
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)]0.304707120114467
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_JLS C-4 (ENG).Rod packing
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]Yes
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)]0.004677436972928
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)]19.561689486336
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_JLS C-5 (ENG).Blowdown valve
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]Yes
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)]0.00010
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)]0.399553711241016
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_JLS C-5 (ENG).Isolation valve
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]No
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)]0.000910635884718643
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)]3.80840543979152
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_JLS C-5 (ENG).Rod packing
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]Yes
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)]0.0077610787941104
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)]32.4579068254848
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_JLS C-6.Blowdown valve
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]Yes
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)]0.00004
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)]0.153577391485552
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_JLS C-6.Isolation valve
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]No
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)]0.000728508707774915
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)]3.04672435183321
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_JLS C-6.Rod packing
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]Yes
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)]0.002102662377266
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)]8.793625388592
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_C-6 (30 MM Pre-compressor).Blowdown valve
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]No
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)]0.000408816051652216
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)]1.70972537005549
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_C-6 (30 MM Pre-compressor).Isolation valve
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]Yes
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)]0
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)]0
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_C-6 (30 MM Pre-compressor).Rod packing
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]No
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)]0.00302691106653153
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)]12.658961463072
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_JLS-7.Blowdown valve
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]Yes
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)]0.00124549425495617
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)]5.20882953922872
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_JLS-7.Isolation valve
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]No
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)]0.000531079862276487
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)]2.2210495659112
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]RECIP_JLS-7.Rod packing
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]Yes
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)]0.005979945325574
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)]25.008959881488


OtherEmissionsFromEquipmentLeaksDetails:
mt CO20.571847952389184
mt CH424.506821154304
Did this facility use leak surveys to calculate emissions from equipment leaks in accordance with 98.232 [per 98.236(q)]?Yes
Were missing data procedures used for any parameters to calculate GHG emissions? [98.235]No
Number of complete equipment leak surveys performed during the calendar year [98.236(q)(1)(i)]1
Optical gas imaging instrument as specified in §60.18 [98.234(a)(1)]Yes
Method 21 [98.234(a)(2)]No
Infrared laser beam illuminated instrument [98.234(a)(3)]No
Acoustic leak detection device [98.234(a)(5)]No
Optical gas imaging instrument as specified in §60.5397a [98.234(a)(6)]No
Method 21 as specified in §60.5397a [98.234(a)(7)]No


GasProcessingEmissionsFactorsRowDetails:
Component Type [98.236(q)(2)(i)]Compressor Components, Gas Service - Connector
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)]3
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)]8784
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)]0.000635367485376
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)]2.657194854912
Component Type [98.236(q)(2)(i)]Compressor Components, Gas Service - Meter
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)]0
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)]8784
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)]0
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)]0
Component Type [98.236(q)(2)(i)]Compressor Components, Gas Service - Open-ended Line
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)]0
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)]8784
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)]0
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)]0
Component Type [98.236(q)(2)(i)]Compressor Components, Gas Service - Pressure Relief Valve
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)]1
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)]8784
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)]0.001502604321408
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)]6.284099460096
Component Type [98.236(q)(2)(i)]Compressor Components, Gas Service - Valve
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)]3
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)]8784
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)]0.001686735864576
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)]7.054163085312
Component Type [98.236(q)(2)(i)]Non-Compressor Components, Gas Service - Connector
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)]6
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)]8784
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)]0.293256123629184
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)]4.394203167744
Component Type [98.236(q)(2)(i)]Non-Compressor components, Gas Service - Meter
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)]0
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)]8784
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)]0
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)]0
Component Type [98.236(q)(2)(i)]Non-Compressor Components, Gas Service - Open-ended Line
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)]0
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)]8784
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)]0
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)]0
Component Type [98.236(q)(2)(i)]Non-Compressor components, Gas Service - Pressure Relief Valve
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)]0
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)]8784
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)]0
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)]0
Component Type [98.236(q)(2)(i)]Non-Compressor Components, Gas Service - Valve
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)]5
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)]8784
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)]0.27476712108864
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)]4.11716058624


Subpart PP: Suppliers of Carbon Dioxide

Gas Information Details

Gas NameCarbon Dioxide
Gas Quantity
Own Result?

Supplier Type: capture 98.420(a)(1)
Calculation Methodology: Flow Meters 1

Meter Details:

Meter Name: 193100008 Acid Gas Meter
Meter Description:
Meter Type: CO2 Flow Meter
Measurement Type: Volumetric - concentration in volume percentage
Annual Mass of CO2 (Metric Tons):
Biomass-Based Percent: 0
Flow Meter Location: NA
Was CO2 Imported or Exported: NA
Dehydration Equipment Upstream? N
Dehydration Equipment Downstream? N
Compression Equipment Upstream? Y
Compression Equipment Downstream? Y
Other Processing Equipment Upstream? N
Other Processing Equipment Downstream? Y
Other Processing Equipment Description: amine unit

Quarterly Volumetric Flow Data
QuarterVolumetric Flow RateCO2 ConcentrationMeasurement StandardDensity
First Quarter (volume %CO2 expressed as a fraction) Industry Standard (mton/scm)
Second Quarter (volume %CO2 expressed as a fraction) Industry Standard (mton/scm)
Third Quarter (volume %CO2 expressed as a fraction) Industry Standard (mton/scm)
Fourth Quarter (volume %CO2 expressed as a fraction) Industry Standard (mton/scm)


End Use Details
End Use CategoryQuantity of CO2
Food and beverage (Metric Tons)
Industrial and municipal water/wastewater treatment (Metric Tons)
Metal fabrication, including welding and cutting (Metric Tons)
Greenhouse uses for plant growth (Metric Tons)
Fumigants (e.g., grain storage) and herbicides (Metric Tons)
Pulp and paper (Metric Tons)
Cleaning and solvent use (Metric Tons)
Fire fighting (Metric Tons)
Transportation and storage of explosives (Metric Tons)
Injection of CO2 for enhanced oil and natural gas recovery that is covered by 40 CFR Part 98, Subpart UU (Metric Tons)
Geologic sequestration of carbon dioxide that is covered by 40 CFR Part 98, Subpart RR (Metric Tons)
Research and Development (Metric Tons)
Other (if other please provide a short description of the use) (Metric Tons)
Unknown (Metric Tons)

Number of days substitute data procedures were used for mass or volume: 0
Number of days substitute data procedures were used for concentration: 0
Number of days substitute data procedures were used for density: 0

Types of Equipment Used
Equipment TypeStandard Used to Calibrate Equipment
Volumetric flow meterindustry standard


Subpart UU: Injection of Carbon Dioxide

Gas Information Details

Facility Information:
Source(s) of CO2 Received
Natural gas processing

Purpose of CO2 Injection
The facility includes a well or group of wells where a CO2 stream was injected into subsurface geologic formations for acid gas disposal during this reporting year.

Flow Meters and Containers

  • Unit Information
  • Name or Identifier: Meter 193100008
    Unit Description: 
    Unit Type: Flow Meter

    Equation UU-2 Summary and Result
    Calculated CO2 Received:  ()

    Quarter 1, January to March
    Quarterly Volume Received
    Volumetric flow through the receiving flow meter in the quarter:  ()
    Standard or method used to calculate the volumetric flow through the receiving flow meter in the quarter: API 21.1
    Number of days for which substitute data procedures were used to calculate the volumetric flow through the receiving flow meter in the quarter: 0
    Quarterly Volume Redelivered
    Volumetric flow through the receiving flow meter that is redelivered to another facility without being injected into your well in the quarter:  ()
    Standard or method used to calculate the volumetric flow through the receiving flow meter that is redelivered to another facility without being injected into your well in the quarter: API 21.1
    Number of days for which substitute data procedures were used to calculate the volumetric flow through the receiving flow meter that is redelivered to another facility without being injected into your well in the quarter: 0
    Quarterly CO2 Concentration
    CO2 concentration in the quarter:  ()
    Standard or method used to calculate CO2 concentration in the quarter: GPA 2261
    Were substitute data procedures used to calculate the CO2 concentration in the quarter? N

    Quarter 2, April to June
    Quarterly Volume Received
    Volumetric flow through the receiving flow meter in the quarter:  ()
    Standard or method used to calculate the volumetric flow through the receiving flow meter in the quarter: API 21.1
    Number of days for which substitute data procedures were used to calculate the volumetric flow through the receiving flow meter in the quarter: 0
    Quarterly Volume Redelivered
    Volumetric flow through the receiving flow meter that is redelivered to another facility without being injected into your well in the quarter:  ()
    Standard or method used to calculate the volumetric flow through the receiving flow meter that is redelivered to another facility without being injected into your well in the quarter: API 21.1
    Number of days for which substitute data procedures were used to calculate the volumetric flow through the receiving flow meter that is redelivered to another facility without being injected into your well in the quarter: 0
    Quarterly CO2 Concentration
    CO2 concentration in the quarter:  ()
    Standard or method used to calculate CO2 concentration in the quarter: GPA 2261
    Were substitute data procedures used to calculate the CO2 concentration in the quarter? N

    Quarter 3, July to September
    Quarterly Volume Received
    Volumetric flow through the receiving flow meter in the quarter:  ()
    Standard or method used to calculate the volumetric flow through the receiving flow meter in the quarter: API 21.1
    Number of days for which substitute data procedures were used to calculate the volumetric flow through the receiving flow meter in the quarter: 0
    Quarterly Volume Redelivered
    Volumetric flow through the receiving flow meter that is redelivered to another facility without being injected into your well in the quarter:  ()
    Standard or method used to calculate the volumetric flow through the receiving flow meter that is redelivered to another facility without being injected into your well in the quarter: API 21.1
    Number of days for which substitute data procedures were used to calculate the volumetric flow through the receiving flow meter that is redelivered to another facility without being injected into your well in the quarter: 0
    Quarterly CO2 Concentration
    CO2 concentration in the quarter:  ()
    Standard or method used to calculate CO2 concentration in the quarter: GPA 2261
    Were substitute data procedures used to calculate the CO2 concentration in the quarter? N

    Quarter 4, October to December
    Quarterly Volume Received
    Volumetric flow through the receiving flow meter in the quarter:  ()
    Standard or method used to calculate the volumetric flow through the receiving flow meter in the quarter: API 21.1
    Number of days for which substitute data procedures were used to calculate the volumetric flow through the receiving flow meter in the quarter: 0
    Quarterly Volume Redelivered
    Volumetric flow through the receiving flow meter that is redelivered to another facility without being injected into your well in the quarter:  ()
    Standard or method used to calculate the volumetric flow through the receiving flow meter that is redelivered to another facility without being injected into your well in the quarter: API 21.1
    Number of days for which substitute data procedures were used to calculate the volumetric flow through the receiving flow meter that is redelivered to another facility without being injected into your well in the quarter: 0
    Quarterly CO2 Concentration
    CO2 concentration in the quarter:  ()
    Standard or method used to calculate CO2 concentration in the quarter: GPA 2261
    Were substitute data procedures used to calculate the CO2 concentration in the quarter? N