Facility Name:ZYBACH CRYOGENIC PLANT
Facility Identifier:
Facility Reporting Year:2020
Facility Location:
Address: 16475 FM 1046
City: Briscoe
State: TX
Postal Code: 79011

Facility Site Details:
CO2 equivalent emissions from facility subparts C-II, SS, and TT (metric tons):15,073
CO2 equivalent emissions from supplier subparts LL-QQ (metric tons):
Biogenic CO2 emissions from facility subparts C-II, SS, and TT (metric tons):0
Cogeneration Unit Emissions Indicator:N
GHG Report Start Date:2020-01-01
GHG Report End Date:2020-12-31
Description of Changes to Calculation Methodology:
Plant Code Indicator:N
Primary NAICS Code:211130
Second Primary NAICS Code:

Parent Company Details:
Parent Company Name:MIDCOAST ENERGY LLC
Address:1501 McKinney Street, Suite #600, Houston,  TX 77010
Percent Ownership Interest:100

Subpart C: General Stationary Fuel Combustion

Gas Information Details

Gas NameCarbon Dioxide
Gas Quantity12,681.4 (Metric Tons)
Own Result?

Gas NameBiogenic Carbon dioxide
Gas Quantity0 (Metric Tons)
Own Result?

Gas NameMethane
Gas Quantity0.24 (Metric Tons)
Own Result?

Gas NameNitrous Oxide
Gas Quantity0.024 (Metric Tons)
Own Result?

Unit Details:
Unit Name : GP-Zybach
Unit Type : OCS (Other combustion source)
Unit Description :
Other Unit Name :
Small Unit Aggregation Details:
Use Ivt Indicator: Y
Highest Maximum Rated Heat Input Capacity: 42.615
Cumulative Maximum Rated Heat Input Capacity: 157.491

Emission Details:
Annual CO2 mass emissions from sorbent: 0 (Metric Tons)
Annual Biogenic CO2 Emissions: 0 (metric tons)
Annual Fossil fuel based CO2 Emissions: 12681.4 (metric tons)

Tier Fuel Details:
Fuel : Natural Gas (Weighted U.S. Average)
Tier Name : Tier 1 (Equation C-1)
Tier Methodology Start Date : 2020-01-01
Tier Methodology End Date : 2020-12-31

Fuel Emission Details :
Total CO2 emissionsTotal CH4 emissionsTotal N2O emissionsTotal CH4 emissions CO2eTotal N2O emissions CO2e
12681.4 (Metric Tons) 0.24 (Metric Tons) 0.024 (Metric Tons) 6 (Metric Tons) 7.1 (Metric Tons)



Subpart W: Petroleum and Natural Gas Systems

Gas Information Details

Gas NameCarbon Dioxide
Gas Quantity388.9 (Metric Tons)
Own Result?

Gas NameMethane
Gas Quantity79.58 (Metric Tons)
Own Result?

Gas NameNitrous Oxide
Gas Quantity0 (Metric Tons)
Own Result?


SubpartWSummaryDetails:
Industry Segment Number3
Industry Segment NameOnshore natural gas processing [98.230(a)(3)]
Total Reported CO2 Emissions (mt CO2)388.9
Total CO2e Emissions (mt CO2e)2378.4
Total Reported CH4 Emissions (mt CH4)79.58
Total Reported N2O Emissions (mt N2O)0.000


SubpartWSourceReportingFormRowDetails:
Source Reporting FormOnshore Production [98.236(aa)(1)]
Required for Selected Industry SegmentNo
Source Reporting FormFacility Overview [98.236(aa)(2-11)]
Required for Selected Industry SegmentYes
Source Reporting FormNatural Gas Pneumatic Devices [98.236(b)]
Required for Selected Industry SegmentNo
Total Reported CO2 Emissions (mt CO2)0.0
Total Reported CH4 Emissions (mt CH4)0.00
Source Reporting FormNatural Gas Driven Pneumatic Pumps [98.236(c)]
Required for Selected Industry SegmentNo
Total Reported CO2 Emissions (mt CO2)0.0
Total Reported CH4 Emissions (mt CH4)0.00
Source Reporting FormAcid Gas Removal Units [98.236(d)]
Required for Selected Industry SegmentYes
Total Reported CO2 Emissions (mt CO2)0.0
Source Reporting FormDehydrators [98.236(e)]
Required for Selected Industry SegmentYes
Total Reported CO2 Emissions (mt CO2)8.5
Total Reported CH4 Emissions (mt CH4)0.01
Total Reported N2O Emissions (mt N2O)0.000
Source Reporting FormWell Venting for Liquids Unloading [98.236(f)]
Required for Selected Industry SegmentNo
Total Reported CO2 Emissions (mt CO2)0.0
Total Reported CH4 Emissions (mt CH4)0.00
Source Reporting FormCompletions and Workovers with Hydraulic Fracturing [98.236(g)]
Required for Selected Industry SegmentNo
Total Reported CO2 Emissions (mt CO2)0.0
Total Reported CH4 Emissions (mt CH4)0.00
Total Reported N2O Emissions (mt N2O)0.000
Source Reporting FormCompletions and Workovers without Hydraulic Fracturing [98.236(h)]
Required for Selected Industry SegmentNo
Total Reported CO2 Emissions (mt CO2)0.0
Total Reported CH4 Emissions (mt CH4)0.00
Total Reported N2O Emissions (mt N2O)0.000
Source Reporting FormBlowdown Vent Stacks [98.236(i)]
Required for Selected Industry SegmentYes
Total Reported CO2 Emissions (mt CO2)0.0
Total Reported CH4 Emissions (mt CH4)0.06
Source Reporting FormAtmospheric Storage Tanks [98.236(j)]
Required for Selected Industry SegmentNo
Total Reported CO2 Emissions (mt CO2)0.0
Total Reported CH4 Emissions (mt CH4)0.00
Total Reported N2O Emissions (mt N2O)0.000
Source Reporting FormTransmission Storage Tanks [98.236(k)]
Required for Selected Industry SegmentNo
Total Reported CO2 Emissions (mt CO2)0.0
Total Reported CH4 Emissions (mt CH4)0.00
Total Reported N2O Emissions (mt N2O)0.000
Source Reporting FormWell Testing [98.236(l)]
Required for Selected Industry SegmentNo
Total Reported CO2 Emissions (mt CO2)0.0
Total Reported CH4 Emissions (mt CH4)0.00
Total Reported N2O Emissions (mt N2O)0.000
Source Reporting FormAssociated Gas Venting and Flaring [98.236(m)]
Required for Selected Industry SegmentNo
Total Reported CO2 Emissions (mt CO2)0.0
Total Reported CH4 Emissions (mt CH4)0.00
Total Reported N2O Emissions (mt N2O)0.000
Source Reporting FormFlare Stacks [98.236(n)]
Required for Selected Industry SegmentYes
Total Reported CO2 Emissions (mt CO2)378.6
Total Reported CH4 Emissions (mt CH4)0.91
Total Reported N2O Emissions (mt N2O)0.000
Source Reporting FormCentrifugal Compressors [98.236(o)]
Required for Selected Industry SegmentYes
Total Reported CO2 Emissions (mt CO2)0.0
Total Reported CH4 Emissions (mt CH4)0.00
Source Reporting FormReciprocating Compressors [98.236(p)]
Required for Selected Industry SegmentYes
Total Reported CO2 Emissions (mt CO2)1.3
Total Reported CH4 Emissions (mt CH4)60.88
Source Reporting FormEquipment Leaks Surveys and Population Counts [98.236(q,r)]
Required for Selected Industry SegmentYes
Total Reported CO2 Emissions (mt CO2)0.5
Total Reported CH4 Emissions (mt CH4)17.72
Source Reporting FormOffshore Petroleum and Natural Gas Production [98.236(s)]
Required for Selected Industry SegmentNo
Total Reported CO2 Emissions (mt CO2)0.0
Total Reported CH4 Emissions (mt CH4)0.00
Total Reported N2O Emissions (mt N2O)0.000
Source Reporting FormEnhanced Oil Recovery Injection Pumps [98.236(w)]
Required for Selected Industry SegmentNo
Total Reported CO2 Emissions (mt CO2)0.0
Source Reporting FormEnhanced Oil Recovery Hydrocarbon Liquids [98.236(x)]
Required for Selected Industry SegmentNo
Total Reported CO2 Emissions (mt CO2)0.0
Source Reporting FormCombustion Equipment at Onshore Petroleum and Natural Gas Production Facilities, Onshore Petroleum and Natural Gas Gathering and Boosting Facilities, and Natural gas Distribution Facilities [98.236(z)]
Required for Selected Industry SegmentNo
Total Reported CO2 Emissions (mt CO2)0.0
Total Reported CH4 Emissions (mt CH4)0.00
Total Reported N2O Emissions (mt N2O)0.000


FacilityOverviewDetails:


FacilityOverviewNaturalGasProcessingRowDetails:
Average mole fraction of CH4 in natural gas received [98.236(aa)(3)(v)]0.83282
Average mole fraction of CO2 in natural gas received [98.236(aa)(3)(vi)]0.00853
Does the facility fractionate NGLs? [98.236(aa)(3)(vii)]No


AcidGasRemovalUnitsDetails:
mt CO20.0
Did the Facility have any acid gas removal units that vent directly to the atmosphere, to a flare or engine, or to a sulfur recovery plant subject to reporting under 98.232 [98.236(d)]?No


DehydratorsDetails:
mt CO28.5
mt CH40.01
mt N2O0.000
Did the facility have any glycol dehydrators with annual average daily natural gas throughputs greater than or equal to 0.4MMscfd subject to reporting under 98.232 [98.236(e)]?Yes
Did the facility have any glycol dehydrators with annual average daily natural gas throughputs less than 0.4MMscfd subject to reporting under 98.232 [98.236(e)]?No
Did the facility have any desiccant dehydrators subject to reporting under 98.232 [98.236(e)]?No
Were missing data procedures used for any parameters to calculate GHG emissions? [98.235]No


SmallGlycolDehydrators:
Emissions vented to flare or regenerator firebox/fire tubes
Emissions that were not vented to a flare or regenerator firebox/fire tubes


DessicantDehydrators:
Emissions vented to flare or regenerator firebox/fire tubes
Emissions that were not vented to a flare or regenerator firebox/fire tubes


GlycolDehydratorsMoreThanSpecifiedValueRowDetails:
Unit ID or Name [98.236(e)(1)(i)]GV-01 (Wet gas dehy)
Glycol dehydrator feed natural gas flow rate determined by engineering estimate based on best available data (MMscfd) [98.236(e)(1)(ii)]11.25
Dehydrator feed natural gas water content (pounds per MMscf) [98.236(e)(1)(iii)]180.18
Dehydrator outlet natural gas water content (pounds per MMscf) [98.236(e)(1)(iv)]7
Glycol dehydrator absorbent circulation pump type [98.236(e)(1)(v)]Electric
Dehydrator absorbent circulation rate (gallons per minute) [98.236(e)(1)(vi)]2.93
Report type of absorbent used [98.236(e)(1)(vii)]Triethylene glycol (TEG)
Report whether stripper gas is used in glycol dehydrator [98.236(e)(1)(viii)]No
Report whether a flash tank separator is used in glycol dehydrator [98.236(e)(1)(ix)]Yes
Total time the glycol dehydrator is operating (hours) [98.236(e)(1)(x)]3404
Temperature of the wet natural gas (°F) [98.236(e)(1)(xi)]100
Pressure of the wet natural gas (psig) [98.236(e)(1)(xii)]253
Concentration of CO2 in wet natural gas (mole fraction) [98.236(e)(1)(xiv)]0.00853
Concentration of CH4 in wet natural gas (mole fraction) [98.236(e)(1)(xiii)]0.83282
Were any dehydrator emissions vented to a vapor recovery device? [98.236(e)(1)(xv)]No
Were any dehydrator emissions vented to a flare or regenerator firebox/fire tubes? [98.236(e)(1)(xvi)]Yes
CO2 Emissions from Flares or Regenerators (mt CO2) [98.236(e)(1)(xvi)(A)]8.548
CH4 Emissions from Flares or Regenerators (mt CH4) [98.236(e)(1)(xvi)(B)]0.00822
N2O Emissions from Flares or Regenerators (mt N2O) [98.236(e)(1)(xvi)(C)]0
Were any dehydrator emissions vented to the atmosphere without being routed to a flare or regenerator firebox/fire tubes? [98.236(e)(1)(xvii)]No


BlowdownVentStacksDetails:
mt CO20.0
mt CH40.06
Did the facility have any blowdown vent stacks subject to reporting under 98.232 [98.236(i)]?Yes
Were missing data procedures used for any parameters to calculate GHG emissions? [98.235]No
How were emissions determined? [98.236(i)]Calculated by equipment or event type


BlowdownEquipmentOrEventEmissionsRowDetails:
Equipment or event type [98.236(i)(1)] [98.236(i)(2)]Facility piping
Total number of blowdowns for equipment or event type, N [98.236(i)(1)(i)]0
Annual total CO2 emissions for each equipment or event type (mt CO2) [98.236(i)(1)(ii)]0
Annual total CH4 emissions for each equipment or event type (mt CH4) [98.236(i)(1)(iii)]0
Equipment or event type [98.236(i)(1)] [98.236(i)(2)]Pipeline venting
Total number of blowdowns for equipment or event type, N [98.236(i)(1)(i)]0
Annual total CO2 emissions for each equipment or event type (mt CO2) [98.236(i)(1)(ii)]0
Annual total CH4 emissions for each equipment or event type (mt CH4) [98.236(i)(1)(iii)]0
Equipment or event type [98.236(i)(1)] [98.236(i)(2)]Compressors
Total number of blowdowns for equipment or event type, N [98.236(i)(1)(i)]39
Annual total CO2 emissions for each equipment or event type (mt CO2) [98.236(i)(1)(ii)]0
Annual total CH4 emissions for each equipment or event type (mt CH4) [98.236(i)(1)(iii)]0.06
Equipment or event type [98.236(i)(1)] [98.236(i)(2)]Scrubbers/strainers
Total number of blowdowns for equipment or event type, N [98.236(i)(1)(i)]0
Annual total CO2 emissions for each equipment or event type (mt CO2) [98.236(i)(1)(ii)]0
Annual total CH4 emissions for each equipment or event type (mt CH4) [98.236(i)(1)(iii)]0
Equipment or event type [98.236(i)(1)] [98.236(i)(2)]Pig launchers and receivers
Total number of blowdowns for equipment or event type, N [98.236(i)(1)(i)]0
Annual total CO2 emissions for each equipment or event type (mt CO2) [98.236(i)(1)(ii)]0
Annual total CH4 emissions for each equipment or event type (mt CH4) [98.236(i)(1)(iii)]0
Equipment or event type [98.236(i)(1)] [98.236(i)(2)]Emergency shutdowns
Total number of blowdowns for equipment or event type, N [98.236(i)(1)(i)]0
Annual total CO2 emissions for each equipment or event type (mt CO2) [98.236(i)(1)(ii)]0
Annual total CH4 emissions for each equipment or event type (mt CH4) [98.236(i)(1)(iii)]0
Equipment or event type [98.236(i)(1)] [98.236(i)(2)]All other equipment with a physical volume greater than or equal 50 cubic feet
Total number of blowdowns for equipment or event type, N [98.236(i)(1)(i)]0
Annual total CO2 emissions for each equipment or event type (mt CO2) [98.236(i)(1)(ii)]0
Annual total CH4 emissions for each equipment or event type (mt CH4) [98.236(i)(1)(iii)]0


FlareStacksDetails:
mt CO2378.6
mt CH40.91
mt N2O0.000
Did the facility have flare stacks subject to reporting under 98.232 [98.236(n)]?Yes
Were missing data procedures used for any parameters to calculate GHG emissions? [98.235]No


UniqueFlareStacksRowDetails:
Unique Name or ID Number for the Flare Stack [98.236(n)(1)]F Pilot
Does the flare stack have a continuous flow monitor on gas to the flare? [98.236(n)(2)]No
Does the flare stack have a continuous gas analyzer on gas to the flare? [98.236(n)(3)]No
Were CEMS used to measure CO2 emissions for the flare stack? [98.233(n)(8)] [98.236(n)(12)]No
Volume of gas sent to flare, Vs (standard cubic feet) [98.236(n)(4)]1051000
Flare combustion efficiency (decimal value) [98.236(n)(6)]0.98
Mole fraction of CH4 in flare feed gas, XCH4 [98.236(n)(7)]0.96275
Mole fraction of CO2 in flare feed gas, XCO2 [98.236(n)(8)]0.00784
Fraction of feed gas sent to un-lit flare, Zu [98.236(n)(5)]0
CO2 emissions (mt CO2) [98.236(n)(9)]54.7
CH4 Emissions (mt CH4) (Eq. W-19) [98.236(n)(10)]0.39
N2O Emissions (mt N2O) (Eq. W-40) [98.236(n)(11)]0
Unique Name or ID Number for the Flare Stack [98.236(n)(1)]F GlycalFlTank
Does the flare stack have a continuous flow monitor on gas to the flare? [98.236(n)(2)]No
Does the flare stack have a continuous gas analyzer on gas to the flare? [98.236(n)(3)]No
Were CEMS used to measure CO2 emissions for the flare stack? [98.233(n)(8)] [98.236(n)(12)]No
Volume of gas sent to flare, Vs (standard cubic feet) [98.236(n)(4)]136377
Flare combustion efficiency (decimal value) [98.236(n)(6)]0.98
Mole fraction of CH4 in flare feed gas, XCH4 [98.236(n)(7)]0.6297
Mole fraction of CO2 in flare feed gas, XCO2 [98.236(n)(8)]0.027983
Fraction of feed gas sent to un-lit flare, Zu [98.236(n)(5)]0
CO2 emissions (mt CO2) [98.236(n)(9)]11.4
CH4 Emissions (mt CH4) (Eq. W-19) [98.236(n)(10)]0.03
N2O Emissions (mt N2O) (Eq. W-40) [98.236(n)(11)]0
Unique Name or ID Number for the Flare Stack [98.236(n)(1)]F SCTruckLoad
Does the flare stack have a continuous flow monitor on gas to the flare? [98.236(n)(2)]No
Does the flare stack have a continuous gas analyzer on gas to the flare? [98.236(n)(3)]No
Were CEMS used to measure CO2 emissions for the flare stack? [98.233(n)(8)] [98.236(n)(12)]No
Volume of gas sent to flare, Vs (standard cubic feet) [98.236(n)(4)]287118
Flare combustion efficiency (decimal value) [98.236(n)(6)]0.98
Mole fraction of CH4 in flare feed gas, XCH4 [98.236(n)(7)]0
Mole fraction of CO2 in flare feed gas, XCO2 [98.236(n)(8)]0
Fraction of feed gas sent to un-lit flare, Zu [98.236(n)(5)]0
CO2 emissions (mt CO2) [98.236(n)(9)]65.4
CH4 Emissions (mt CH4) (Eq. W-19) [98.236(n)(10)]0
N2O Emissions (mt N2O) (Eq. W-40) [98.236(n)(11)]0
Unique Name or ID Number for the Flare Stack [98.236(n)(1)]F SCTank
Does the flare stack have a continuous flow monitor on gas to the flare? [98.236(n)(2)]No
Does the flare stack have a continuous gas analyzer on gas to the flare? [98.236(n)(3)]No
Were CEMS used to measure CO2 emissions for the flare stack? [98.233(n)(8)] [98.236(n)(12)]No
Volume of gas sent to flare, Vs (standard cubic feet) [98.236(n)(4)]219561
Flare combustion efficiency (decimal value) [98.236(n)(6)]0.98
Mole fraction of CH4 in flare feed gas, XCH4 [98.236(n)(7)]0
Mole fraction of CO2 in flare feed gas, XCO2 [98.236(n)(8)]0
Fraction of feed gas sent to un-lit flare, Zu [98.236(n)(5)]0
CO2 emissions (mt CO2) [98.236(n)(9)]48.8
CH4 Emissions (mt CH4) (Eq. W-19) [98.236(n)(10)]0
N2O Emissions (mt N2O) (Eq. W-40) [98.236(n)(11)]0
Unique Name or ID Number for the Flare Stack [98.236(n)(1)]F TankLoadMSS
Does the flare stack have a continuous flow monitor on gas to the flare? [98.236(n)(2)]No
Does the flare stack have a continuous gas analyzer on gas to the flare? [98.236(n)(3)]No
Were CEMS used to measure CO2 emissions for the flare stack? [98.233(n)(8)] [98.236(n)(12)]No
Volume of gas sent to flare, Vs (standard cubic feet) [98.236(n)(4)]2209825
Flare combustion efficiency (decimal value) [98.236(n)(6)]0.98
Mole fraction of CH4 in flare feed gas, XCH4 [98.236(n)(7)]0.58157
Mole fraction of CO2 in flare feed gas, XCO2 [98.236(n)(8)]0.00627
Fraction of feed gas sent to un-lit flare, Zu [98.236(n)(5)]0
CO2 emissions (mt CO2) [98.236(n)(9)]198.3
CH4 Emissions (mt CH4) (Eq. W-19) [98.236(n)(10)]0.49
N2O Emissions (mt N2O) (Eq. W-40) [98.236(n)(11)]0


CentrifugalCompressorsDetails:
mt CO20.0
mt CH40.00
Did the facility have any centrifugal compressors subject to reporting under 98.232 [98.236(o)]?No


ReciprocatingCompressorsDetails:
mt CO21.3
mt CH460.88
Did the facility have any reciprocating compressors subject to reporting under 98.232 [98.236(p)]?Yes
Were missing data procedures used for any parameters to calculate GHG emissions? [98.235]No


ReciprocatingCompressorsActivityDataRowDetails:
Unique name or ID for reciprocating compressor [98.236(p)(1)(i)]Zybach: Unit A
Total time in operating-mode (hours) [98.236(p)(1)(ii)]3136
Total time in standby-pressurized-mode (hours) [98.236(p)(1)(iii)]0
Total time in not-operating-depressurized-mode (hours) [98.236(p)(1)(iv)]5648
Compressor measured in operating-mode? [98.236(p)(1)(v)]Yes
Compressor measured in standby-pressurized-mode? [98.236(p)(1)(vi)]No
Compressor measured in not-operating-depressurized-mode? [98.236(p)(1)(vii)]Yes
Compressor had blind flanges installed? [98.236(p)(1)(xii)]No
Power output of compressor driver (hp) [98.236(p)(1)(xiii)]1002
Compressor had scheduled depressurized shutdown during reporting year? [98.236(p)(1)(xiv)]Yes
Unique name or ID for reciprocating compressor [98.236(p)(1)(i)]Zybach: Unit B
Total time in operating-mode (hours) [98.236(p)(1)(ii)]2632
Total time in standby-pressurized-mode (hours) [98.236(p)(1)(iii)]0
Total time in not-operating-depressurized-mode (hours) [98.236(p)(1)(iv)]6152
Compressor measured in operating-mode? [98.236(p)(1)(v)]Yes
Compressor measured in standby-pressurized-mode? [98.236(p)(1)(vi)]No
Compressor measured in not-operating-depressurized-mode? [98.236(p)(1)(vii)]Yes
Compressor had blind flanges installed? [98.236(p)(1)(xii)]No
Power output of compressor driver (hp) [98.236(p)(1)(xiii)]1156
Compressor had scheduled depressurized shutdown during reporting year? [98.236(p)(1)(xiv)]Yes
Unique name or ID for reciprocating compressor [98.236(p)(1)(i)]Zybach: Unit C
Total time in operating-mode (hours) [98.236(p)(1)(ii)]3351
Total time in standby-pressurized-mode (hours) [98.236(p)(1)(iii)]0
Total time in not-operating-depressurized-mode (hours) [98.236(p)(1)(iv)]5433
Compressor measured in operating-mode? [98.236(p)(1)(v)]Yes
Compressor measured in standby-pressurized-mode? [98.236(p)(1)(vi)]No
Compressor measured in not-operating-depressurized-mode? [98.236(p)(1)(vii)]Yes
Compressor had blind flanges installed? [98.236(p)(1)(xii)]No
Power output of compressor driver (hp) [98.236(p)(1)(xiii)]1101
Compressor had scheduled depressurized shutdown during reporting year? [98.236(p)(1)(xiv)]Yes
Unique name or ID for reciprocating compressor [98.236(p)(1)(i)]Zybach: Unit D
Total time in operating-mode (hours) [98.236(p)(1)(ii)]2456
Total time in standby-pressurized-mode (hours) [98.236(p)(1)(iii)]0
Total time in not-operating-depressurized-mode (hours) [98.236(p)(1)(iv)]6328
Compressor measured in operating-mode? [98.236(p)(1)(v)]No
Compressor measured in standby-pressurized-mode? [98.236(p)(1)(vi)]No
Compressor measured in not-operating-depressurized-mode? [98.236(p)(1)(vii)]Yes
Compressor had blind flanges installed? [98.236(p)(1)(xii)]No
Power output of compressor driver (hp) [98.236(p)(1)(xiii)]1186
Compressor had scheduled depressurized shutdown during reporting year? [98.236(p)(1)(xiv)]Yes
Unique name or ID for reciprocating compressor [98.236(p)(1)(i)]Zybach: Unit E
Total time in operating-mode (hours) [98.236(p)(1)(ii)]2111
Total time in standby-pressurized-mode (hours) [98.236(p)(1)(iii)]0
Total time in not-operating-depressurized-mode (hours) [98.236(p)(1)(iv)]6673
Compressor measured in operating-mode? [98.236(p)(1)(v)]Yes
Compressor measured in standby-pressurized-mode? [98.236(p)(1)(vi)]No
Compressor measured in not-operating-depressurized-mode? [98.236(p)(1)(vii)]Yes
Compressor had blind flanges installed? [98.236(p)(1)(xii)]No
Power output of compressor driver (hp) [98.236(p)(1)(xiii)]3738
Compressor had scheduled depressurized shutdown during reporting year? [98.236(p)(1)(xiv)]Yes
Unique name or ID for reciprocating compressor [98.236(p)(1)(i)]Zybach: Unit F
Total time in operating-mode (hours) [98.236(p)(1)(ii)]1731
Total time in standby-pressurized-mode (hours) [98.236(p)(1)(iii)]0
Total time in not-operating-depressurized-mode (hours) [98.236(p)(1)(iv)]7053
Compressor measured in operating-mode? [98.236(p)(1)(v)]No
Compressor measured in standby-pressurized-mode? [98.236(p)(1)(vi)]No
Compressor measured in not-operating-depressurized-mode? [98.236(p)(1)(vii)]Yes
Compressor had blind flanges installed? [98.236(p)(1)(xii)]No
Power output of compressor driver (hp) [98.236(p)(1)(xiii)]3874
Compressor had scheduled depressurized shutdown during reporting year? [98.236(p)(1)(xiv)]Yes


ReciprocatingCompressorSourceRowDetails:
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]Zybach: Unit A
Reciprocating compressor source [98.236(p)(2)(i)(B)]Blowdown valve
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]Zybach: Unit A_BV
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]Zybach: Unit A
Reciprocating compressor source [98.236(p)(2)(i)(B)]Isolation valve
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]Zybach: Unit A_IVND
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]Zybach: Unit A
Reciprocating compressor source [98.236(p)(2)(i)(B)]Rod packing
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]Zybach: Unit A_RP
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]Zybach: Unit B
Reciprocating compressor source [98.236(p)(2)(i)(B)]Blowdown valve
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]Zybach: Unit B_BV
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]Zybach: Unit B
Reciprocating compressor source [98.236(p)(2)(i)(B)]Isolation valve
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]Zybach: Unit B_IVND
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]Zybach: Unit B
Reciprocating compressor source [98.236(p)(2)(i)(B)]Rod packing
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]Zybach: Unit B_RP
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]Zybach: Unit C
Reciprocating compressor source [98.236(p)(2)(i)(B)]Blowdown valve
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]Zybach: Unit C_BV
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]Zybach: Unit C
Reciprocating compressor source [98.236(p)(2)(i)(B)]Isolation valve
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]Zybach: Unit C_IVND
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]Zybach: Unit C
Reciprocating compressor source [98.236(p)(2)(i)(B)]Rod packing
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]Zybach: Unit C_RP
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]Zybach: Unit D
Reciprocating compressor source [98.236(p)(2)(i)(B)]Blowdown valve
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]Zybach: Unit D_BV
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]Zybach: Unit D
Reciprocating compressor source [98.236(p)(2)(i)(B)]Isolation valve
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]Zybach: Unit D_IVND
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]Zybach: Unit D
Reciprocating compressor source [98.236(p)(2)(i)(B)]Rod packing
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]Zybach: Unit D_RP
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]Zybach: Unit E
Reciprocating compressor source [98.236(p)(2)(i)(B)]Blowdown valve
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]Zybach: Unit E_BV
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]Zybach: Unit E
Reciprocating compressor source [98.236(p)(2)(i)(B)]Isolation valve
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]Zybach: Unit E_IVND
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]Zybach: Unit E
Reciprocating compressor source [98.236(p)(2)(i)(B)]Rod packing
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]Zybach: Unit E_RP
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]Zybach: Unit F
Reciprocating compressor source [98.236(p)(2)(i)(B)]Blowdown valve
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]Zybach: Unit F_BV
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]Zybach: Unit F
Reciprocating compressor source [98.236(p)(2)(i)(B)]Isolation valve
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]Zybach: Unit F_IVND
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]Zybach: Unit F
Reciprocating compressor source [98.236(p)(2)(i)(B)]Rod packing
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]Zybach: Unit F_RP


ReciprocatingCompressorsLeakOrVentSampleDataRowDetails:
Unique Name or ID for leak or vent (Specify) [98.236(p)(2)(i)(C)] [98.236(p)(3)(i)(A)]Zybach: Unit A_BV
Measurement date (mm/dd/yyyy) [98.236(p)(3)(i)(B)]2020-02-06
Measurement method [98.236(p)(3)(i)(C)]High volume sampler
Measured flow rate (standard cubic feet/hour) [98.236(p)(3)(i)(D)]4.851
Is the measurement location prior to or after commingling with non-compressor emission sources? [98.236(p)(3)(i)(F)]Prior to commingling
Compressors in “Operating mode”Zybach: Unit A
Unique Name or ID for leak or vent (Specify) [98.236(p)(2)(i)(C)] [98.236(p)(3)(i)(A)]Zybach: Unit A_IVND
Measurement date (mm/dd/yyyy) [98.236(p)(3)(i)(B)]2020-02-06
Measurement method [98.236(p)(3)(i)(C)]Screening/Acoustic leak detection
Measured flow rate (standard cubic feet/hour) [98.236(p)(3)(i)(D)]0
Is the measurement location prior to or after commingling with non-compressor emission sources? [98.236(p)(3)(i)(F)]Prior to commingling
Compressors in “Not-operating mode”Zybach: Unit A-NOD
Unique Name or ID for leak or vent (Specify) [98.236(p)(2)(i)(C)] [98.236(p)(3)(i)(A)]Zybach: Unit A_RP
Measurement date (mm/dd/yyyy) [98.236(p)(3)(i)(B)]2020-02-06
Measurement method [98.236(p)(3)(i)(C)]High volume sampler
Measured flow rate (standard cubic feet/hour) [98.236(p)(3)(i)(D)]81.856
Is the measurement location prior to or after commingling with non-compressor emission sources? [98.236(p)(3)(i)(F)]Prior to commingling
Compressors in “Operating mode”Zybach: Unit A
Unique Name or ID for leak or vent (Specify) [98.236(p)(2)(i)(C)] [98.236(p)(3)(i)(A)]Zybach: Unit B_BV
Measurement date (mm/dd/yyyy) [98.236(p)(3)(i)(B)]2020-02-06
Measurement method [98.236(p)(3)(i)(C)]Screening/Optical gas imaging
Measured flow rate (standard cubic feet/hour) [98.236(p)(3)(i)(D)]0
Is the measurement location prior to or after commingling with non-compressor emission sources? [98.236(p)(3)(i)(F)]Prior to commingling
Compressors in “Operating mode”Zybach: Unit B
Unique Name or ID for leak or vent (Specify) [98.236(p)(2)(i)(C)] [98.236(p)(3)(i)(A)]Zybach: Unit B_IVND
Measurement date (mm/dd/yyyy) [98.236(p)(3)(i)(B)]2020-02-06
Measurement method [98.236(p)(3)(i)(C)]Screening/Acoustic leak detection
Measured flow rate (standard cubic feet/hour) [98.236(p)(3)(i)(D)]0
Is the measurement location prior to or after commingling with non-compressor emission sources? [98.236(p)(3)(i)(F)]Prior to commingling
Compressors in “Not-operating mode”Zybach: Unit B-NOD
Unique Name or ID for leak or vent (Specify) [98.236(p)(2)(i)(C)] [98.236(p)(3)(i)(A)]Zybach: Unit B_RP
Measurement date (mm/dd/yyyy) [98.236(p)(3)(i)(B)]2020-02-06
Measurement method [98.236(p)(3)(i)(C)]High volume sampler
Measured flow rate (standard cubic feet/hour) [98.236(p)(3)(i)(D)]57.602
Is the measurement location prior to or after commingling with non-compressor emission sources? [98.236(p)(3)(i)(F)]Prior to commingling
Compressors in “Operating mode”Zybach: Unit B
Unique Name or ID for leak or vent (Specify) [98.236(p)(2)(i)(C)] [98.236(p)(3)(i)(A)]Zybach: Unit C_BV
Measurement date (mm/dd/yyyy) [98.236(p)(3)(i)(B)]2020-02-06
Measurement method [98.236(p)(3)(i)(C)]Screening/Optical gas imaging
Measured flow rate (standard cubic feet/hour) [98.236(p)(3)(i)(D)]0
Is the measurement location prior to or after commingling with non-compressor emission sources? [98.236(p)(3)(i)(F)]Prior to commingling
Compressors in “Operating mode”Zybach: Unit C
Unique Name or ID for leak or vent (Specify) [98.236(p)(2)(i)(C)] [98.236(p)(3)(i)(A)]Zybach: Unit C_IVND
Measurement date (mm/dd/yyyy) [98.236(p)(3)(i)(B)]2020-02-06
Measurement method [98.236(p)(3)(i)(C)]Screening/Acoustic leak detection
Measured flow rate (standard cubic feet/hour) [98.236(p)(3)(i)(D)]0
Is the measurement location prior to or after commingling with non-compressor emission sources? [98.236(p)(3)(i)(F)]Prior to commingling
Compressors in “Not-operating mode”Zybach: Unit C-NOD
Unique Name or ID for leak or vent (Specify) [98.236(p)(2)(i)(C)] [98.236(p)(3)(i)(A)]Zybach: Unit C_RP
Measurement date (mm/dd/yyyy) [98.236(p)(3)(i)(B)]2020-02-06
Measurement method [98.236(p)(3)(i)(C)]High volume sampler
Measured flow rate (standard cubic feet/hour) [98.236(p)(3)(i)(D)]20.009
Is the measurement location prior to or after commingling with non-compressor emission sources? [98.236(p)(3)(i)(F)]Prior to commingling
Compressors in “Operating mode”Zybach: Unit C
Unique Name or ID for leak or vent (Specify) [98.236(p)(2)(i)(C)] [98.236(p)(3)(i)(A)]Zybach: Unit D_IVND
Measurement date (mm/dd/yyyy) [98.236(p)(3)(i)(B)]2020-02-06
Measurement method [98.236(p)(3)(i)(C)]Screening/Acoustic leak detection
Measured flow rate (standard cubic feet/hour) [98.236(p)(3)(i)(D)]0
Is the measurement location prior to or after commingling with non-compressor emission sources? [98.236(p)(3)(i)(F)]Prior to commingling
Compressors in “Not-operating mode”Zybach: Unit D-NOD
Unique Name or ID for leak or vent (Specify) [98.236(p)(2)(i)(C)] [98.236(p)(3)(i)(A)]Zybach: Unit E_BV
Measurement date (mm/dd/yyyy) [98.236(p)(3)(i)(B)]2020-02-06
Measurement method [98.236(p)(3)(i)(C)]High volume sampler
Measured flow rate (standard cubic feet/hour) [98.236(p)(3)(i)(D)]197.06
Is the measurement location prior to or after commingling with non-compressor emission sources? [98.236(p)(3)(i)(F)]Prior to commingling
Compressors in “Operating mode”Zybach: Unit E
Unique Name or ID for leak or vent (Specify) [98.236(p)(2)(i)(C)] [98.236(p)(3)(i)(A)]Zybach: Unit E_IVND
Measurement date (mm/dd/yyyy) [98.236(p)(3)(i)(B)]2020-02-06
Measurement method [98.236(p)(3)(i)(C)]Acoustic leak detection
Measured flow rate (standard cubic feet/hour) [98.236(p)(3)(i)(D)]15.18
Is the measurement location prior to or after commingling with non-compressor emission sources? [98.236(p)(3)(i)(F)]Prior to commingling
Compressors in “Not-operating mode”Zybach: Unit E-NOD
Unique Name or ID for leak or vent (Specify) [98.236(p)(2)(i)(C)] [98.236(p)(3)(i)(A)]Zybach: Unit E_RP
Measurement date (mm/dd/yyyy) [98.236(p)(3)(i)(B)]2020-02-06
Measurement method [98.236(p)(3)(i)(C)]High volume sampler
Measured flow rate (standard cubic feet/hour) [98.236(p)(3)(i)(D)]397.152
Is the measurement location prior to or after commingling with non-compressor emission sources? [98.236(p)(3)(i)(F)]Prior to commingling
Compressors in “Operating mode”Zybach: Unit E
Unique Name or ID for leak or vent (Specify) [98.236(p)(2)(i)(C)] [98.236(p)(3)(i)(A)]Zybach: Unit F_IVND
Measurement date (mm/dd/yyyy) [98.236(p)(3)(i)(B)]2020-02-06
Measurement method [98.236(p)(3)(i)(C)]High volume sampler
Measured flow rate (standard cubic feet/hour) [98.236(p)(3)(i)(D)]114.597
Is the measurement location prior to or after commingling with non-compressor emission sources? [98.236(p)(3)(i)(F)]Prior to commingling
Compressors in “Not-operating mode”Zybach: Unit F-NOD


ReciprocatingCompressorsEmissionFactorsSampleDataRowDetails:
Compressor Mode [98.236(p)(3)(ii)(A)]Operating
Compressor Source [98.236(p)(3)(ii)(A)]Blowdown valve
Compressor mode-source combination reporter emission factor, EFs,m (standard cubic feet per hour) [98.236(p)(3)(ii)(B)]39
Total number of compressors measured in the compressor mode-source combination in current reporting year and preceding two reporting years, Countm [98.236(p)(3)(ii)(C)]6
Is the reporter emission factor facility-specific or based on all of the reporter's applicable facilities? [98.236(p)(3)(ii)(D)]Facility-specific
Compressor Mode [98.236(p)(3)(ii)(A)]Operating
Compressor Source [98.236(p)(3)(ii)(A)]Rod packing
Compressor mode-source combination reporter emission factor, EFs,m (standard cubic feet per hour) [98.236(p)(3)(ii)(B)]144
Total number of compressors measured in the compressor mode-source combination in current reporting year and preceding two reporting years, Countm [98.236(p)(3)(ii)(C)]6
Is the reporter emission factor facility-specific or based on all of the reporter's applicable facilities? [98.236(p)(3)(ii)(D)]Facility-specific
Compressor Mode [98.236(p)(3)(ii)(A)]Standby-pressurized
Compressor Source [98.236(p)(3)(ii)(A)]Blowdown valve
Compressor mode-source combination reporter emission factor, EFs,m (standard cubic feet per hour) [98.236(p)(3)(ii)(B)]2.2
Total number of compressors measured in the compressor mode-source combination in current reporting year and preceding two reporting years, Countm [98.236(p)(3)(ii)(C)]6
Is the reporter emission factor facility-specific or based on all of the reporter's applicable facilities? [98.236(p)(3)(ii)(D)]Facility-specific
Compressor Mode [98.236(p)(3)(ii)(A)]Not-operating-depressurized
Compressor Source [98.236(p)(3)(ii)(A)]Isolation valve
Compressor mode-source combination reporter emission factor, EFs,m (standard cubic feet per hour) [98.236(p)(3)(ii)(B)]25.4
Total number of compressors measured in the compressor mode-source combination in current reporting year and preceding two reporting years, Countm [98.236(p)(3)(ii)(C)]6
Is the reporter emission factor facility-specific or based on all of the reporter's applicable facilities? [98.236(p)(3)(ii)(D)]Facility-specific


ReciprocatingCompressorsLeakOrVentDataRowDetails:
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]Zybach: Unit A_BV
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]Yes
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)]0
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)]0.24
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]Zybach: Unit A_IVND
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]Yes
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)]0
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)]0
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]Zybach: Unit A_RP
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]Yes
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)]0.1
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)]4.1
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]Zybach: Unit B_BV
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]Yes
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)]0
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)]0
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]Zybach: Unit B_IVND
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]Yes
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)]0
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)]0
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]Zybach: Unit B_RP
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]Yes
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)]0.1
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)]2.42
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]Zybach: Unit C_BV
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]Yes
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)]0
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)]0
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]Zybach: Unit C_IVND
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]Yes
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)]0
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)]0
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]Zybach: Unit C_RP
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]Yes
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)]0
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)]1.07
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]Zybach: Unit D_BV
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]No
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)]0
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)]1.53
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]Zybach: Unit D_IVND
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]Yes
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)]0
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)]0
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]Zybach: Unit D_RP
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]No
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)]0.2
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)]5.66
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]Zybach: Unit E_BV
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]Yes
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)]0.2
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)]7.69
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]Zybach: Unit E_IVND
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]Yes
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)]0
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)]1.87
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]Zybach: Unit E_RP
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]Yes
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)]0.3
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)]15.5
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]Zybach: Unit F_BV
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]No
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)]0
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)]1.25
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]Zybach: Unit F_IVND
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]Yes
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)]0.3
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)]14.94
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]Zybach: Unit F_RP
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]No
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)]0.1
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)]4.61


OtherEmissionsFromEquipmentLeaksDetails:
mt CO20.5
mt CH417.72
Did this facility use leak surveys to calculate emissions from equipment leaks in accordance with 98.232 [per 98.236(q)]?Yes
Were missing data procedures used for any parameters to calculate GHG emissions? [98.235]No
Number of complete equipment leak surveys performed during the calendar year [98.236(q)(1)(i)]1
Optical gas imaging instrument as specified in §60.18 [98.234(a)(1)]Yes
Method 21 [98.234(a)(2)]No
Infrared laser beam illuminated instrument [98.234(a)(3)]No
Acoustic leak detection device [98.234(a)(5)]No
Optical gas imaging instrument as specified in §60.5397a [98.234(a)(6)]No
Method 21 as specified in §60.5397a [98.234(a)(7)]No


GasProcessingEmissionsFactorsRowDetails:
Component Type [98.236(q)(2)(i)]Compressor Components, Gas Service - Valve
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)]0
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)]0
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)]0
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)]0
Component Type [98.236(q)(2)(i)]Compressor Components, Gas Service - Connector
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)]4
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)]8784
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)]0.1
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)]3.63
Component Type [98.236(q)(2)(i)]Compressor Components, Gas Service - Open-ended Line
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)]0
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)]0
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)]0
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)]0
Component Type [98.236(q)(2)(i)]Compressor Components, Gas Service - Pressure Relief Valve
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)]0
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)]0
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)]0
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)]0
Component Type [98.236(q)(2)(i)]Compressor Components, Gas Service - Meter
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)]0
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)]0
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)]0
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)]0
Component Type [98.236(q)(2)(i)]Non-Compressor Components, Gas Service - Valve
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)]7
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)]8784
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)]0.2
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)]6.31
Component Type [98.236(q)(2)(i)]Non-Compressor Components, Gas Service - Connector
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)]9
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)]8784
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)]0.2
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)]7.22
Component Type [98.236(q)(2)(i)]Non-Compressor Components, Gas Service - Open-ended Line
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)]0
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)]0
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)]0
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)]0
Component Type [98.236(q)(2)(i)]Non-Compressor components, Gas Service - Pressure Relief Valve
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)]2
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)]8784
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)]0
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)]0.56
Component Type [98.236(q)(2)(i)]Non-Compressor components, Gas Service - Meter
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)]0
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)]0
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)]0
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)]0