Source Reporting Form | Onshore Production [98.236(aa)(1)] |
Required for Selected Industry Segment | No |
Source Reporting Form | Facility Overview [98.236(aa)(2-11)] |
Required for Selected Industry Segment | Yes |
Source Reporting Form | Natural Gas Pneumatic Devices [98.236(b)] |
Required for Selected Industry Segment | No |
Total Reported CO2 Emissions (mt CO2) | 0.0 |
Total Reported CH4 Emissions (mt CH4) | 0.00 |
Source Reporting Form | Natural Gas Driven Pneumatic Pumps [98.236(c)] |
Required for Selected Industry Segment | No |
Total Reported CO2 Emissions (mt CO2) | 0.0 |
Total Reported CH4 Emissions (mt CH4) | 0.00 |
Source Reporting Form | Acid Gas Removal Units [98.236(d)] |
Required for Selected Industry Segment | Yes |
Total Reported CO2 Emissions (mt CO2) | 19670.0 |
Source Reporting Form | Dehydrators [98.236(e)] |
Required for Selected Industry Segment | Yes |
Total Reported CO2 Emissions (mt CO2) | 395.0 |
Total Reported CH4 Emissions (mt CH4) | 2.46 |
Total Reported N2O Emissions (mt N2O) | 0.012 |
Source Reporting Form | Well Venting for Liquids Unloading [98.236(f)] |
Required for Selected Industry Segment | No |
Total Reported CO2 Emissions (mt CO2) | 0.0 |
Total Reported CH4 Emissions (mt CH4) | 0.00 |
Source Reporting Form | Completions and Workovers with Hydraulic Fracturing [98.236(g)] |
Required for Selected Industry Segment | No |
Total Reported CO2 Emissions (mt CO2) | 0.0 |
Total Reported CH4 Emissions (mt CH4) | 0.00 |
Total Reported N2O Emissions (mt N2O) | 0.000 |
Source Reporting Form | Completions and Workovers without Hydraulic Fracturing [98.236(h)] |
Required for Selected Industry Segment | No |
Total Reported CO2 Emissions (mt CO2) | 0.0 |
Total Reported CH4 Emissions (mt CH4) | 0.00 |
Total Reported N2O Emissions (mt N2O) | 0.000 |
Source Reporting Form | Blowdown Vent Stacks [98.236(i)] |
Required for Selected Industry Segment | Yes |
Total Reported CO2 Emissions (mt CO2) | 0.1 |
Total Reported CH4 Emissions (mt CH4) | 17.84 |
Source Reporting Form | Atmospheric Storage Tanks [98.236(j)] |
Required for Selected Industry Segment | No |
Total Reported CO2 Emissions (mt CO2) | 0.0 |
Total Reported CH4 Emissions (mt CH4) | 0.00 |
Total Reported N2O Emissions (mt N2O) | 0.000 |
Source Reporting Form | Transmission Storage Tanks [98.236(k)] |
Required for Selected Industry Segment | No |
Total Reported CO2 Emissions (mt CO2) | 0.0 |
Total Reported CH4 Emissions (mt CH4) | 0.00 |
Total Reported N2O Emissions (mt N2O) | 0.000 |
Source Reporting Form | Well Testing [98.236(l)] |
Required for Selected Industry Segment | No |
Total Reported CO2 Emissions (mt CO2) | 0.0 |
Total Reported CH4 Emissions (mt CH4) | 0.00 |
Total Reported N2O Emissions (mt N2O) | 0.000 |
Source Reporting Form | Associated Gas Venting and Flaring [98.236(m)] |
Required for Selected Industry Segment | No |
Total Reported CO2 Emissions (mt CO2) | 0.0 |
Total Reported CH4 Emissions (mt CH4) | 0.00 |
Total Reported N2O Emissions (mt N2O) | 0.000 |
Source Reporting Form | Flare Stacks [98.236(n)] |
Required for Selected Industry Segment | Yes |
Total Reported CO2 Emissions (mt CO2) | 13694.9 |
Total Reported CH4 Emissions (mt CH4) | 106.38 |
Total Reported N2O Emissions (mt N2O) | 0.031 |
Source Reporting Form | Centrifugal Compressors [98.236(o)] |
Required for Selected Industry Segment | Yes |
Total Reported CO2 Emissions (mt CO2) | 0.4 |
Total Reported CH4 Emissions (mt CH4) | 127.16 |
Source Reporting Form | Reciprocating Compressors [98.236(p)] |
Required for Selected Industry Segment | Yes |
Total Reported CO2 Emissions (mt CO2) | 0.3 |
Total Reported CH4 Emissions (mt CH4) | 15.67 |
Source Reporting Form | Equipment Leaks Surveys and Population Counts [98.236(q,r)] |
Required for Selected Industry Segment | Yes |
Total Reported CO2 Emissions (mt CO2) | 0.1 |
Total Reported CH4 Emissions (mt CH4) | 6.07 |
Source Reporting Form | Offshore Petroleum and Natural Gas Production [98.236(s)] |
Required for Selected Industry Segment | No |
Total Reported CO2 Emissions (mt CO2) | 0.0 |
Total Reported CH4 Emissions (mt CH4) | 0.00 |
Total Reported N2O Emissions (mt N2O) | 0.000 |
Source Reporting Form | Enhanced Oil Recovery Injection Pumps [98.236(w)] |
Required for Selected Industry Segment | No |
Total Reported CO2 Emissions (mt CO2) | 0.0 |
Source Reporting Form | Enhanced Oil Recovery Hydrocarbon Liquids [98.236(x)] |
Required for Selected Industry Segment | No |
Total Reported CO2 Emissions (mt CO2) | 0.0 |
Source Reporting Form | Combustion Equipment at Onshore Petroleum and Natural Gas Production Facilities, Onshore Petroleum and Natural Gas Gathering and Boosting Facilities, and Natural gas Distribution Facilities [98.236(z)] |
Required for Selected Industry Segment | No |
Total Reported CO2 Emissions (mt CO2) | 0.0 |
Total Reported CH4 Emissions (mt CH4) | 0.00 |
Total Reported N2O Emissions (mt N2O) | 0.000 |
Unit ID or Name [98.236(e)(1)(i)] | WGC - Markham -- NG Plant --- MATAGORDA, TX (321) 220 - Markham |
Glycol dehydrator feed natural gas flow rate determined by engineering estimate based on best available data (MMscfd) [98.236(e)(1)(ii)] | 226.51 |
Dehydrator feed natural gas water content (pounds per MMscf) [98.236(e)(1)(iii)] | 61.29 |
Dehydrator outlet natural gas water content (pounds per MMscf) [98.236(e)(1)(iv)] | 5.31 |
Glycol dehydrator absorbent circulation pump type [98.236(e)(1)(v)] | Electric |
Dehydrator absorbent circulation rate (gallons per minute) [98.236(e)(1)(vi)] | 21 |
Report type of absorbent used [98.236(e)(1)(vii)] | Triethylene glycol (TEG) |
Report whether stripper gas is used in glycol dehydrator [98.236(e)(1)(viii)] | No |
Report whether a flash tank separator is used in glycol dehydrator [98.236(e)(1)(ix)] | Yes |
Total time the glycol dehydrator is operating (hours) [98.236(e)(1)(x)] | 7985 |
Temperature of the wet natural gas (°F) [98.236(e)(1)(xi)] | 100 |
Pressure of the wet natural gas (psig) [98.236(e)(1)(xii)] | 925 |
Concentration of CO2 in wet natural gas (mole fraction) [98.236(e)(1)(xiv)] | 0.00206 |
Concentration of CH4 in wet natural gas (mole fraction) [98.236(e)(1)(xiii)] | 0.977 |
Were any dehydrator emissions vented to a vapor recovery device? [98.236(e)(1)(xv)] | No |
Were any dehydrator emissions vented to a flare or regenerator firebox/fire tubes? [98.236(e)(1)(xvi)] | Yes |
CO2 Emissions from Flares or Regenerators (mt CO2) [98.236(e)(1)(xvi)(A)] | 395.0438424 |
CH4 Emissions from Flares or Regenerators (mt CH4) [98.236(e)(1)(xvi)(B)] | 2.4551874 |
N2O Emissions from Flares or Regenerators (mt N2O) [98.236(e)(1)(xvi)(C)] | 0.011572 |
Were any dehydrator emissions vented to the atmosphere without being routed to a flare or regenerator firebox/fire tubes? [98.236(e)(1)(xvii)] | No |
Equipment or event type [98.236(i)(1)] [98.236(i)(2)] | Facility piping |
Total number of blowdowns for equipment or event type, N [98.236(i)(1)(i)] | 236 |
Annual total CO2 emissions for each equipment or event type (mt CO2) [98.236(i)(1)(ii)] | 0.0511728 |
Annual total CH4 emissions for each equipment or event type (mt CH4) [98.236(i)(1)(iii)] | 10.9140726 |
Equipment or event type [98.236(i)(1)] [98.236(i)(2)] | Pipeline venting |
Total number of blowdowns for equipment or event type, N [98.236(i)(1)(i)] | 0 |
Annual total CO2 emissions for each equipment or event type (mt CO2) [98.236(i)(1)(ii)] | 0 |
Annual total CH4 emissions for each equipment or event type (mt CH4) [98.236(i)(1)(iii)] | 0 |
Equipment or event type [98.236(i)(1)] [98.236(i)(2)] | Compressors |
Total number of blowdowns for equipment or event type, N [98.236(i)(1)(i)] | 233 |
Annual total CO2 emissions for each equipment or event type (mt CO2) [98.236(i)(1)(ii)] | 0.0298016 |
Annual total CH4 emissions for each equipment or event type (mt CH4) [98.236(i)(1)(iii)] | 2.1423671 |
Equipment or event type [98.236(i)(1)] [98.236(i)(2)] | Scrubbers/strainers |
Total number of blowdowns for equipment or event type, N [98.236(i)(1)(i)] | 97 |
Annual total CO2 emissions for each equipment or event type (mt CO2) [98.236(i)(1)(ii)] | 0.0438304 |
Annual total CH4 emissions for each equipment or event type (mt CH4) [98.236(i)(1)(iii)] | 2.6948216 |
Equipment or event type [98.236(i)(1)] [98.236(i)(2)] | Pig launchers and receivers |
Total number of blowdowns for equipment or event type, N [98.236(i)(1)(i)] | 0 |
Annual total CO2 emissions for each equipment or event type (mt CO2) [98.236(i)(1)(ii)] | 0 |
Annual total CH4 emissions for each equipment or event type (mt CH4) [98.236(i)(1)(iii)] | 0 |
Equipment or event type [98.236(i)(1)] [98.236(i)(2)] | Emergency shutdowns |
Total number of blowdowns for equipment or event type, N [98.236(i)(1)(i)] | 0 |
Annual total CO2 emissions for each equipment or event type (mt CO2) [98.236(i)(1)(ii)] | 0 |
Annual total CH4 emissions for each equipment or event type (mt CH4) [98.236(i)(1)(iii)] | 0 |
Equipment or event type [98.236(i)(1)] [98.236(i)(2)] | All other equipment with a physical volume greater than or equal 50 cubic feet |
Total number of blowdowns for equipment or event type, N [98.236(i)(1)(i)] | 236 |
Annual total CO2 emissions for each equipment or event type (mt CO2) [98.236(i)(1)(ii)] | 0.0127315 |
Annual total CH4 emissions for each equipment or event type (mt CH4) [98.236(i)(1)(iii)] | 2.0858902 |
Unique Name or ID Number for the Flare Stack [98.236(n)(1)] | Markham Gas Plant Flare |
Does the flare stack have a continuous flow monitor on gas to the flare? [98.236(n)(2)] | No |
Does the flare stack have a continuous gas analyzer on gas to the flare? [98.236(n)(3)] | No |
Were CEMS used to measure CO2 emissions for the flare stack? [98.233(n)(8)] [98.236(n)(12)] | No |
Volume of gas sent to flare, Vs (standard cubic feet) [98.236(n)(4)] | 29681647 |
Flare combustion efficiency (decimal value) [98.236(n)(6)] | 0.98 |
Mole fraction of CH4 in flare feed gas, XCH4 [98.236(n)(7)] | 0.9408347 |
Mole fraction of CO2 in flare feed gas, XCO2 [98.236(n)(8)] | 0.0037433 |
Fraction of feed gas sent to un-lit flare, Zu [98.236(n)(5)] | 0.0003734 |
CO2 emissions (mt CO2) [98.236(n)(9)] | 1278.2389091 |
CH4 Emissions (mt CH4) (Eq. W-19) [98.236(n)(10)] | 24.0950885 |
N2O Emissions (mt N2O) (Eq. W-40) [98.236(n)(11)] | 0.0028975 |
Unique Name or ID Number for the Flare Stack [98.236(n)(1)] | Markham Gas Plant - Thermal Oxidizer |
Does the flare stack have a continuous flow monitor on gas to the flare? [98.236(n)(2)] | Yes |
Does the flare stack have a continuous gas analyzer on gas to the flare? [98.236(n)(3)] | No |
Were CEMS used to measure CO2 emissions for the flare stack? [98.233(n)(8)] [98.236(n)(12)] | No |
Volume of gas sent to flare, Vs (standard cubic feet) [98.236(n)(4)] | 309281630 |
Flare combustion efficiency (decimal value) [98.236(n)(6)] | 0.98 |
Mole fraction of CH4 in flare feed gas, XCH4 [98.236(n)(7)] | 0.6934485 |
Mole fraction of CO2 in flare feed gas, XCO2 [98.236(n)(8)] | 0.001075 |
Fraction of feed gas sent to un-lit flare, Zu [98.236(n)(5)] | 0.0000384 |
CO2 emissions (mt CO2) [98.236(n)(9)] | 12416.6638691 |
CH4 Emissions (mt CH4) (Eq. W-19) [98.236(n)(10)] | 82.2799198 |
N2O Emissions (mt N2O) (Eq. W-40) [98.236(n)(11)] | 0.028039 |
Compressor ID or Unique Name [98.236(o)(1)(i)] | Saturn C-1100 |
Total time in operating-mode (hours) [98.236(o)(1)(ii)] | 3304.3 |
Total time in not-operating-depressurized-mode (hours) [98.236(o)(1)(iii)] | 5479.7 |
Compressor measured in operating-mode? [98.236(o)(1)(iv)] | Yes |
Compressor measured in not-operating-depressurized-mode? [98.236(o)(1)(v)] | No |
Compressor had blind flanges installed? [98.236(o)(1)(x)] | No |
Seal Type (wet or dry) [98.236(o)(1)(xi)] | Wet |
Number of wet seals [98.236(o)(1)(xii)] | 1 |
Power output of compressor driver (hp) [98.236(o)(1)(xiii)] | 1236 |
Compressor had scheduled depressurized shutdown during reporting year? [98.236(o)(1)(xiv)] | Yes |
Compressor ID or Unique Name [98.236(o)(1)(i)] | Saturn C-1200 |
Total time in operating-mode (hours) [98.236(o)(1)(ii)] | 3045.1 |
Total time in not-operating-depressurized-mode (hours) [98.236(o)(1)(iii)] | 5738.9 |
Compressor measured in operating-mode? [98.236(o)(1)(iv)] | No |
Compressor measured in not-operating-depressurized-mode? [98.236(o)(1)(v)] | Yes |
Compressor had blind flanges installed? [98.236(o)(1)(x)] | No |
Seal Type (wet or dry) [98.236(o)(1)(xi)] | Wet |
Number of wet seals [98.236(o)(1)(xii)] | 1 |
Power output of compressor driver (hp) [98.236(o)(1)(xiii)] | 1236 |
Compressor had scheduled depressurized shutdown during reporting year? [98.236(o)(1)(xiv)] | Yes |
Compressor ID or Unique Name [98.236(o)(1)(i)] | Mars TXP1 C-140 |
Total time in operating-mode (hours) [98.236(o)(1)(ii)] | 6912.5 |
Total time in not-operating-depressurized-mode (hours) [98.236(o)(1)(iii)] | 1871.5 |
Compressor measured in operating-mode? [98.236(o)(1)(iv)] | Yes |
Compressor measured in not-operating-depressurized-mode? [98.236(o)(1)(v)] | No |
Compressor had blind flanges installed? [98.236(o)(1)(x)] | No |
Seal Type (wet or dry) [98.236(o)(1)(xi)] | Dry |
Power output of compressor driver (hp) [98.236(o)(1)(xiii)] | 15225 |
Compressor had scheduled depressurized shutdown during reporting year? [98.236(o)(1)(xiv)] | Yes |
Compressor ID or Unique Name [98.236(o)(1)(i)] | C-210 Regen Gas Compressor |
Total time in operating-mode (hours) [98.236(o)(1)(ii)] | 829.9 |
Total time in not-operating-depressurized-mode (hours) [98.236(o)(1)(iii)] | 7954.1 |
Compressor measured in operating-mode? [98.236(o)(1)(iv)] | Yes |
Compressor measured in not-operating-depressurized-mode? [98.236(o)(1)(v)] | No |
Compressor had blind flanges installed? [98.236(o)(1)(x)] | No |
Seal Type (wet or dry) [98.236(o)(1)(xi)] | Dry |
Power output of compressor driver (hp) [98.236(o)(1)(xiii)] | 200 |
Compressor had scheduled depressurized shutdown during reporting year? [98.236(o)(1)(xiv)] | Yes |
Compressor ID or Unique Name [98.236(o)(1)(i)] | Taurus TXP2 C-240 |
Total time in operating-mode (hours) [98.236(o)(1)(ii)] | 1698.7 |
Total time in not-operating-depressurized-mode (hours) [98.236(o)(1)(iii)] | 7085.3 |
Compressor measured in operating-mode? [98.236(o)(1)(iv)] | No |
Compressor measured in not-operating-depressurized-mode? [98.236(o)(1)(v)] | Yes |
Compressor had blind flanges installed? [98.236(o)(1)(x)] | No |
Seal Type (wet or dry) [98.236(o)(1)(xi)] | Dry |
Power output of compressor driver (hp) [98.236(o)(1)(xiii)] | 11353 |
Compressor had scheduled depressurized shutdown during reporting year? [98.236(o)(1)(xiv)] | Yes |
Unique Compressor Name or ID [98.236(o)(2)(i)(A)] | Saturn C-1100 |
Centrifugal compressor source [98.236(o)(2)(i)(B)] | Blowdown valve |
Unique Name or ID for leak or vent [98.236(o)(2)(i)(C)] | Saturn C-1100 BDV |
Unique Compressor Name or ID [98.236(o)(2)(i)(A)] | Saturn C-1100 |
Centrifugal compressor source [98.236(o)(2)(i)(B)] | Isolation valve |
Unique Name or ID for leak or vent [98.236(o)(2)(i)(C)] | Saturn C-1100 ISO |
Unique Compressor Name or ID [98.236(o)(2)(i)(A)] | Saturn C-1100 |
Centrifugal compressor source [98.236(o)(2)(i)(B)] | Wet seal |
Unique Name or ID for leak or vent [98.236(o)(2)(i)(C)] | Saturn C-1100 WSDV |
Unique Compressor Name or ID [98.236(o)(2)(i)(A)] | Saturn C-1200 |
Centrifugal compressor source [98.236(o)(2)(i)(B)] | Blowdown valve |
Unique Name or ID for leak or vent [98.236(o)(2)(i)(C)] | Saturn C-1200 BDV |
Unique Compressor Name or ID [98.236(o)(2)(i)(A)] | Saturn C-1200 |
Centrifugal compressor source [98.236(o)(2)(i)(B)] | Isolation valve |
Unique Name or ID for leak or vent [98.236(o)(2)(i)(C)] | Saturn C-1200 ISO |
Unique Compressor Name or ID [98.236(o)(2)(i)(A)] | Saturn C-1200 |
Centrifugal compressor source [98.236(o)(2)(i)(B)] | Wet seal |
Unique Name or ID for leak or vent [98.236(o)(2)(i)(C)] | Saturn C-1200 WSDV |
Unique Compressor Name or ID [98.236(o)(2)(i)(A)] | Mars TXP1 C-140 |
Centrifugal compressor source [98.236(o)(2)(i)(B)] | Blowdown valve |
Unique Name or ID for leak or vent [98.236(o)(2)(i)(C)] | Mars TXP1 C-140 BDV |
Unique Compressor Name or ID [98.236(o)(2)(i)(A)] | Mars TXP1 C-140 |
Centrifugal compressor source [98.236(o)(2)(i)(B)] | Isolation valve |
Unique Name or ID for leak or vent [98.236(o)(2)(i)(C)] | Mars TXP1 C-140 ISO |
Unique Compressor Name or ID [98.236(o)(2)(i)(A)] | Mars TXP1 C-140 |
Centrifugal compressor source [98.236(o)(2)(i)(B)] | Wet seal |
Unique Compressor Name or ID [98.236(o)(2)(i)(A)] | C-210 Regen Gas Compressor |
Centrifugal compressor source [98.236(o)(2)(i)(B)] | Blowdown valve |
Unique Name or ID for leak or vent [98.236(o)(2)(i)(C)] | C-210 Regen Gas Compressor BDV |
Unique Compressor Name or ID [98.236(o)(2)(i)(A)] | C-210 Regen Gas Compressor |
Centrifugal compressor source [98.236(o)(2)(i)(B)] | Isolation valve |
Unique Name or ID for leak or vent [98.236(o)(2)(i)(C)] | C-210 Regen Gas Compressor ISO |
Unique Compressor Name or ID [98.236(o)(2)(i)(A)] | C-210 Regen Gas Compressor |
Centrifugal compressor source [98.236(o)(2)(i)(B)] | Wet seal |
Unique Compressor Name or ID [98.236(o)(2)(i)(A)] | Taurus TXP2 C-240 |
Centrifugal compressor source [98.236(o)(2)(i)(B)] | Blowdown valve |
Unique Name or ID for leak or vent [98.236(o)(2)(i)(C)] | Taurus TXP2 C-240 BDV |
Unique Compressor Name or ID [98.236(o)(2)(i)(A)] | Taurus TXP2 C-240 |
Centrifugal compressor source [98.236(o)(2)(i)(B)] | Isolation valve |
Unique Name or ID for leak or vent [98.236(o)(2)(i)(C)] | Taurus TXP2 C-240 ISO |
Unique Compressor Name or ID [98.236(o)(2)(i)(A)] | Taurus TXP2 C-240 |
Centrifugal compressor source [98.236(o)(2)(i)(B)] | Wet seal |
Unique Name or ID for leak or vent (Specify) [98.236(o)(3)(i)(A)] | Saturn C-1100 BDV |
Measurement date (mm/dd/yyyy) [98.236(o)(3)(i)(B)] | 2020-07-20 |
Measurement method [98.236(o)(3)(i)(C)] | Acoustic leak detection |
Measured flow rate, MTs,m, MTs,g,avg (standard cubic feet/hour) [98.236(o)(3)(i)(D)] | 0 |
Is the measurement location prior to or after commingling with non-compressor emission sources? [98.236(o)(3)(i)(F)] | Not manifolded |
Compressors in “Operating mode” | Saturn C-1100 |
Unique Name or ID for leak or vent (Specify) [98.236(o)(3)(i)(A)] | Saturn C-1100 WSDV |
Measurement date (mm/dd/yyyy) [98.236(o)(3)(i)(B)] | 2020-07-20 |
Measurement method [98.236(o)(3)(i)(C)] | Temporary meter |
Measured flow rate, MTs,m, MTs,g,avg (standard cubic feet/hour) [98.236(o)(3)(i)(D)] | 5.27 |
Is the measurement location prior to or after commingling with non-compressor emission sources? [98.236(o)(3)(i)(F)] | Not manifolded |
Compressors in “Operating mode” | Saturn C-1100 |
Unique Name or ID for leak or vent (Specify) [98.236(o)(3)(i)(A)] | Saturn C-1200 ISO |
Measurement date (mm/dd/yyyy) [98.236(o)(3)(i)(B)] | 2020-07-20 |
Measurement method [98.236(o)(3)(i)(C)] | High volume sampler |
Measured flow rate, MTs,m, MTs,g,avg (standard cubic feet/hour) [98.236(o)(3)(i)(D)] | 213.718 |
Is the measurement location prior to or after commingling with non-compressor emission sources? [98.236(o)(3)(i)(F)] | Not manifolded |
Compressors in “Not-operating mode” | Saturn C-1200 |
Unique Name or ID for leak or vent (Specify) [98.236(o)(3)(i)(A)] | Mars TXP1 C-140 BDV |
Measurement date (mm/dd/yyyy) [98.236(o)(3)(i)(B)] | 2020-07-20 |
Measurement method [98.236(o)(3)(i)(C)] | High volume sampler |
Measured flow rate, MTs,m, MTs,g,avg (standard cubic feet/hour) [98.236(o)(3)(i)(D)] | 12.296 |
Is the measurement location prior to or after commingling with non-compressor emission sources? [98.236(o)(3)(i)(F)] | Not manifolded |
Compressors in “Operating mode” | Mars TXP1 C-140 |
Unique Name or ID for leak or vent (Specify) [98.236(o)(3)(i)(A)] | C-210 Regen Gas Compressor BDV |
Measurement date (mm/dd/yyyy) [98.236(o)(3)(i)(B)] | 2020-07-20 |
Measurement method [98.236(o)(3)(i)(C)] | Screening/Optical gas imaging |
Measured flow rate, MTs,m, MTs,g,avg (standard cubic feet/hour) [98.236(o)(3)(i)(D)] | 0 |
Is the measurement location prior to or after commingling with non-compressor emission sources? [98.236(o)(3)(i)(F)] | Not manifolded |
Compressors in “Operating mode” | C-210 Regen Gas Compressor |
Unique Name or ID for leak or vent (Specify) [98.236(o)(3)(i)(A)] | Taurus TXP2 C-240 ISO |
Measurement date (mm/dd/yyyy) [98.236(o)(3)(i)(B)] | 2020-07-20 |
Measurement method [98.236(o)(3)(i)(C)] | High volume sampler |
Measured flow rate, MTs,m, MTs,g,avg (standard cubic feet/hour) [98.236(o)(3)(i)(D)] | 396.99 |
Is the measurement location prior to or after commingling with non-compressor emission sources? [98.236(o)(3)(i)(F)] | Not manifolded |
Compressors in “Not-operating mode” | Taurus TXP2 C-240 |
Compressor Mode [98.236(o)(3)(ii)(A)] | Operating |
Compressor Source [98.236(o)(3)(ii)(A)] | Wet seal |
Compressor mode-source combination reporter emission factor, EFs,m (standard cubic feet per hour) [98.236(o)(3)(ii)(B)] | 68.5 |
Total number of compressors measured in the compressor mode-source combination in current reporting year and preceding two reporting years [98.236(o)(3)(ii)(C)] | 29 |
Is the reporter emission factor facility-specific or based on all of the reporter's applicable facilities? [98.236(o)(3)(ii)(D)] | All applicable facilities |
Compressor Mode [98.236(o)(3)(ii)(A)] | Operating |
Compressor Source [98.236(o)(3)(ii)(A)] | Blowdown valve |
Compressor mode-source combination reporter emission factor, EFs,m (standard cubic feet per hour) [98.236(o)(3)(ii)(B)] | 36.6 |
Total number of compressors measured in the compressor mode-source combination in current reporting year and preceding two reporting years [98.236(o)(3)(ii)(C)] | 79 |
Is the reporter emission factor facility-specific or based on all of the reporter's applicable facilities? [98.236(o)(3)(ii)(D)] | All applicable facilities |
Compressor Mode [98.236(o)(3)(ii)(A)] | Not-operating |
Compressor Source [98.236(o)(3)(ii)(A)] | Isolation valve |
Compressor mode-source combination reporter emission factor, EFs,m (standard cubic feet per hour) [98.236(o)(3)(ii)(B)] | 164 |
Total number of compressors measured in the compressor mode-source combination in current reporting year and preceding two reporting years [98.236(o)(3)(ii)(C)] | 20 |
Is the reporter emission factor facility-specific or based on all of the reporter's applicable facilities? [98.236(o)(3)(ii)(D)] | All applicable facilities |
Unique Name or ID for leak or vent [98.236(o)(2)(i)(C)] | Saturn C-1100 BDV |
Leak or vent for a single compressor source or a manifolded group? [98.236(o)(2)(ii)(A)] [98.236(o)(1)(vi)] | Single |
Where are leak or vent emissions released? [98.236(o)(2)(ii)(A)] [98.236(o)(1)(vii) through (ix)] | Atmosphere |
Was an "as found" measurement conducted on the leak or vent? [98.236(o)(2)(ii)(B)] | Yes |
Were continuous measurements conducted on the leak or vent? [98.236(o)(2)(ii)(C)] | No |
CO2 emissions vented to atmosphere (mt CO2) [98.236(o)(2)(ii)(D)(1)] | 0 |
CH4 emissions vented to atmosphere (mt CH4) [98.236(o)(2)(ii)(D)(2)] | 0 |
Unique Name or ID for leak or vent [98.236(o)(2)(i)(C)] | Saturn C-1100 ISO |
Leak or vent for a single compressor source or a manifolded group? [98.236(o)(2)(ii)(A)] [98.236(o)(1)(vi)] | Single |
Where are leak or vent emissions released? [98.236(o)(2)(ii)(A)] [98.236(o)(1)(vii) through (ix)] | Atmosphere |
Was an "as found" measurement conducted on the leak or vent? [98.236(o)(2)(ii)(B)] | No |
Were continuous measurements conducted on the leak or vent? [98.236(o)(2)(ii)(C)] | No |
CO2 emissions vented to atmosphere (mt CO2) [98.236(o)(2)(ii)(D)(1)] | 0 |
CH4 emissions vented to atmosphere (mt CH4) [98.236(o)(2)(ii)(D)(2)] | 16.25 |
Unique Name or ID for leak or vent [98.236(o)(2)(i)(C)] | Saturn C-1100 WSDV |
Leak or vent for a single compressor source or a manifolded group? [98.236(o)(2)(ii)(A)] [98.236(o)(1)(vi)] | Single |
Where are leak or vent emissions released? [98.236(o)(2)(ii)(A)] [98.236(o)(1)(vii) through (ix)] | Atmosphere |
Was an "as found" measurement conducted on the leak or vent? [98.236(o)(2)(ii)(B)] | Yes |
Were continuous measurements conducted on the leak or vent? [98.236(o)(2)(ii)(C)] | No |
CO2 emissions vented to atmosphere (mt CO2) [98.236(o)(2)(ii)(D)(1)] | 0 |
CH4 emissions vented to atmosphere (mt CH4) [98.236(o)(2)(ii)(D)(2)] | 0.31 |
Unique Name or ID for leak or vent [98.236(o)(2)(i)(C)] | Saturn C-1200 BDV |
Leak or vent for a single compressor source or a manifolded group? [98.236(o)(2)(ii)(A)] [98.236(o)(1)(vi)] | Single |
Where are leak or vent emissions released? [98.236(o)(2)(ii)(A)] [98.236(o)(1)(vii) through (ix)] | Atmosphere |
Was an "as found" measurement conducted on the leak or vent? [98.236(o)(2)(ii)(B)] | No |
Were continuous measurements conducted on the leak or vent? [98.236(o)(2)(ii)(C)] | No |
CO2 emissions vented to atmosphere (mt CO2) [98.236(o)(2)(ii)(D)(1)] | 0 |
CH4 emissions vented to atmosphere (mt CH4) [98.236(o)(2)(ii)(D)(2)] | 2.02 |
Unique Name or ID for leak or vent [98.236(o)(2)(i)(C)] | Saturn C-1200 ISO |
Leak or vent for a single compressor source or a manifolded group? [98.236(o)(2)(ii)(A)] [98.236(o)(1)(vi)] | Single |
Where are leak or vent emissions released? [98.236(o)(2)(ii)(A)] [98.236(o)(1)(vii) through (ix)] | Atmosphere |
Was an "as found" measurement conducted on the leak or vent? [98.236(o)(2)(ii)(B)] | Yes |
Were continuous measurements conducted on the leak or vent? [98.236(o)(2)(ii)(C)] | No |
CO2 emissions vented to atmosphere (mt CO2) [98.236(o)(2)(ii)(D)(1)] | 0.1 |
CH4 emissions vented to atmosphere (mt CH4) [98.236(o)(2)(ii)(D)(2)] | 22.17 |
Unique Name or ID for leak or vent [98.236(o)(2)(i)(C)] | Saturn C-1200 WSDV |
Leak or vent for a single compressor source or a manifolded group? [98.236(o)(2)(ii)(A)] [98.236(o)(1)(vi)] | Single |
Where are leak or vent emissions released? [98.236(o)(2)(ii)(A)] [98.236(o)(1)(vii) through (ix)] | Atmosphere |
Was an "as found" measurement conducted on the leak or vent? [98.236(o)(2)(ii)(B)] | No |
Were continuous measurements conducted on the leak or vent? [98.236(o)(2)(ii)(C)] | No |
CO2 emissions vented to atmosphere (mt CO2) [98.236(o)(2)(ii)(D)(1)] | 0 |
CH4 emissions vented to atmosphere (mt CH4) [98.236(o)(2)(ii)(D)(2)] | 3.77 |
Unique Name or ID for leak or vent [98.236(o)(2)(i)(C)] | Mars TXP1 C-140 BDV |
Leak or vent for a single compressor source or a manifolded group? [98.236(o)(2)(ii)(A)] [98.236(o)(1)(vi)] | Single |
Where are leak or vent emissions released? [98.236(o)(2)(ii)(A)] [98.236(o)(1)(vii) through (ix)] | Atmosphere |
Was an "as found" measurement conducted on the leak or vent? [98.236(o)(2)(ii)(B)] | Yes |
Were continuous measurements conducted on the leak or vent? [98.236(o)(2)(ii)(C)] | No |
CO2 emissions vented to atmosphere (mt CO2) [98.236(o)(2)(ii)(D)(1)] | 0 |
CH4 emissions vented to atmosphere (mt CH4) [98.236(o)(2)(ii)(D)(2)] | 1.54 |
Unique Name or ID for leak or vent [98.236(o)(2)(i)(C)] | Mars TXP1 C-140 ISO |
Leak or vent for a single compressor source or a manifolded group? [98.236(o)(2)(ii)(A)] [98.236(o)(1)(vi)] | Single |
Where are leak or vent emissions released? [98.236(o)(2)(ii)(A)] [98.236(o)(1)(vii) through (ix)] | Atmosphere |
Was an "as found" measurement conducted on the leak or vent? [98.236(o)(2)(ii)(B)] | No |
Were continuous measurements conducted on the leak or vent? [98.236(o)(2)(ii)(C)] | No |
CO2 emissions vented to atmosphere (mt CO2) [98.236(o)(2)(ii)(D)(1)] | 0 |
CH4 emissions vented to atmosphere (mt CH4) [98.236(o)(2)(ii)(D)(2)] | 5.55 |
Unique Name or ID for leak or vent [98.236(o)(2)(i)(C)] | C-210 Regen Gas Compressor BDV |
Leak or vent for a single compressor source or a manifolded group? [98.236(o)(2)(ii)(A)] [98.236(o)(1)(vi)] | Single |
Where are leak or vent emissions released? [98.236(o)(2)(ii)(A)] [98.236(o)(1)(vii) through (ix)] | Atmosphere |
Was an "as found" measurement conducted on the leak or vent? [98.236(o)(2)(ii)(B)] | Yes |
Were continuous measurements conducted on the leak or vent? [98.236(o)(2)(ii)(C)] | No |
CO2 emissions vented to atmosphere (mt CO2) [98.236(o)(2)(ii)(D)(1)] | 0 |
CH4 emissions vented to atmosphere (mt CH4) [98.236(o)(2)(ii)(D)(2)] | 0 |
Unique Name or ID for leak or vent [98.236(o)(2)(i)(C)] | C-210 Regen Gas Compressor ISO |
Leak or vent for a single compressor source or a manifolded group? [98.236(o)(2)(ii)(A)] [98.236(o)(1)(vi)] | Single |
Where are leak or vent emissions released? [98.236(o)(2)(ii)(A)] [98.236(o)(1)(vii) through (ix)] | Atmosphere |
Was an "as found" measurement conducted on the leak or vent? [98.236(o)(2)(ii)(B)] | No |
Were continuous measurements conducted on the leak or vent? [98.236(o)(2)(ii)(C)] | No |
CO2 emissions vented to atmosphere (mt CO2) [98.236(o)(2)(ii)(D)(1)] | 0.1 |
CH4 emissions vented to atmosphere (mt CH4) [98.236(o)(2)(ii)(D)(2)] | 23.58 |
Unique Name or ID for leak or vent [98.236(o)(2)(i)(C)] | Taurus TXP2 C-240 BDV |
Leak or vent for a single compressor source or a manifolded group? [98.236(o)(2)(ii)(A)] [98.236(o)(1)(vi)] | Single |
Where are leak or vent emissions released? [98.236(o)(2)(ii)(A)] [98.236(o)(1)(vii) through (ix)] | Atmosphere |
Was an "as found" measurement conducted on the leak or vent? [98.236(o)(2)(ii)(B)] | No |
Were continuous measurements conducted on the leak or vent? [98.236(o)(2)(ii)(C)] | No |
CO2 emissions vented to atmosphere (mt CO2) [98.236(o)(2)(ii)(D)(1)] | 0 |
CH4 emissions vented to atmosphere (mt CH4) [98.236(o)(2)(ii)(D)(2)] | 1.12 |
Unique Name or ID for leak or vent [98.236(o)(2)(i)(C)] | Taurus TXP2 C-240 ISO |
Leak or vent for a single compressor source or a manifolded group? [98.236(o)(2)(ii)(A)] [98.236(o)(1)(vi)] | Single |
Where are leak or vent emissions released? [98.236(o)(2)(ii)(A)] [98.236(o)(1)(vii) through (ix)] | Atmosphere |
Was an "as found" measurement conducted on the leak or vent? [98.236(o)(2)(ii)(B)] | Yes |
Were continuous measurements conducted on the leak or vent? [98.236(o)(2)(ii)(C)] | No |
CO2 emissions vented to atmosphere (mt CO2) [98.236(o)(2)(ii)(D)(1)] | 0.2 |
CH4 emissions vented to atmosphere (mt CH4) [98.236(o)(2)(ii)(D)(2)] | 50.85 |
Unique name or ID for reciprocating compressor [98.236(p)(1)(i)] | Cat 3001 |
Total time in operating-mode (hours) [98.236(p)(1)(ii)] | 8034.8 |
Total time in standby-pressurized-mode (hours) [98.236(p)(1)(iii)] | 624.2 |
Total time in not-operating-depressurized-mode (hours) [98.236(p)(1)(iv)] | 125 |
Compressor measured in operating-mode? [98.236(p)(1)(v)] | Yes |
Compressor measured in standby-pressurized-mode? [98.236(p)(1)(vi)] | No |
Compressor measured in not-operating-depressurized-mode? [98.236(p)(1)(vii)] | No |
Compressor had blind flanges installed? [98.236(p)(1)(xii)] | No |
Power output of compressor driver (hp) [98.236(p)(1)(xiii)] | 1150 |
Compressor had scheduled depressurized shutdown during reporting year? [98.236(p)(1)(xiv)] | Yes |
Unique name or ID for reciprocating compressor [98.236(p)(1)(i)] | Cat 3002 |
Total time in operating-mode (hours) [98.236(p)(1)(ii)] | 8074.8 |
Total time in standby-pressurized-mode (hours) [98.236(p)(1)(iii)] | 621.2 |
Total time in not-operating-depressurized-mode (hours) [98.236(p)(1)(iv)] | 88 |
Compressor measured in operating-mode? [98.236(p)(1)(v)] | Yes |
Compressor measured in standby-pressurized-mode? [98.236(p)(1)(vi)] | No |
Compressor measured in not-operating-depressurized-mode? [98.236(p)(1)(vii)] | No |
Compressor had blind flanges installed? [98.236(p)(1)(xii)] | No |
Power output of compressor driver (hp) [98.236(p)(1)(xiii)] | 1150 |
Compressor had scheduled depressurized shutdown during reporting year? [98.236(p)(1)(xiv)] | Yes |
Unique Name or ID for leak or vent (Specify) [98.236(p)(2)(i)(C)] [98.236(p)(3)(i)(A)] | Cat 3001 BDV |
Measurement date (mm/dd/yyyy) [98.236(p)(3)(i)(B)] | 2020-07-20 |
Measurement method [98.236(p)(3)(i)(C)] | Screening/Optical gas imaging |
Measured flow rate (standard cubic feet/hour) [98.236(p)(3)(i)(D)] | 0 |
Is the measurement location prior to or after commingling with non-compressor emission sources? [98.236(p)(3)(i)(F)] | Not manifolded |
Compressors in “Operating mode” | Cat 3001
|
Unique Name or ID for leak or vent (Specify) [98.236(p)(2)(i)(C)] [98.236(p)(3)(i)(A)] | Cat 3001 RPV |
Measurement date (mm/dd/yyyy) [98.236(p)(3)(i)(B)] | 2020-07-20 |
Measurement method [98.236(p)(3)(i)(C)] | High volume sampler |
Measured flow rate (standard cubic feet/hour) [98.236(p)(3)(i)(D)] | 21.08 |
Is the measurement location prior to or after commingling with non-compressor emission sources? [98.236(p)(3)(i)(F)] | Not manifolded |
Compressors in “Operating mode” | Cat 3001
|
Unique Name or ID for leak or vent (Specify) [98.236(p)(2)(i)(C)] [98.236(p)(3)(i)(A)] | Cat 3002 BDV |
Measurement date (mm/dd/yyyy) [98.236(p)(3)(i)(B)] | 2020-07-20 |
Measurement method [98.236(p)(3)(i)(C)] | Screening/Optical gas imaging |
Measured flow rate (standard cubic feet/hour) [98.236(p)(3)(i)(D)] | 0 |
Is the measurement location prior to or after commingling with non-compressor emission sources? [98.236(p)(3)(i)(F)] | Not manifolded |
Compressors in “Operating mode” | Cat 3002
|
Unique Name or ID for leak or vent (Specify) [98.236(p)(2)(i)(C)] [98.236(p)(3)(i)(A)] | Cat 3002 RPV |
Measurement date (mm/dd/yyyy) [98.236(p)(3)(i)(B)] | 2020-07-20 |
Measurement method [98.236(p)(3)(i)(C)] | High volume sampler |
Measured flow rate (standard cubic feet/hour) [98.236(p)(3)(i)(D)] | 93.686 |
Is the measurement location prior to or after commingling with non-compressor emission sources? [98.236(p)(3)(i)(F)] | Not manifolded |
Compressors in “Operating mode” | Cat 3002
|
Compressor Mode [98.236(p)(3)(ii)(A)] | Operating |
Compressor Source [98.236(p)(3)(ii)(A)] | Blowdown valve |
Compressor mode-source combination reporter emission factor, EFs,m (standard cubic feet per hour) [98.236(p)(3)(ii)(B)] | 17.0706308 |
Total number of compressors measured in the compressor mode-source combination in current reporting year and preceding two reporting years, Countm [98.236(p)(3)(ii)(C)] | 65 |
Is the reporter emission factor facility-specific or based on all of the reporter's applicable facilities? [98.236(p)(3)(ii)(D)] | All applicable facilities |
Compressor Mode [98.236(p)(3)(ii)(A)] | Operating |
Compressor Source [98.236(p)(3)(ii)(A)] | Rod packing |
Compressor mode-source combination reporter emission factor, EFs,m (standard cubic feet per hour) [98.236(p)(3)(ii)(B)] | 191.2312194 |
Total number of compressors measured in the compressor mode-source combination in current reporting year and preceding two reporting years, Countm [98.236(p)(3)(ii)(C)] | 155 |
Is the reporter emission factor facility-specific or based on all of the reporter's applicable facilities? [98.236(p)(3)(ii)(D)] | All applicable facilities |
Compressor Mode [98.236(p)(3)(ii)(A)] | Standby-pressurized |
Compressor Source [98.236(p)(3)(ii)(A)] | Blowdown valve |
Compressor mode-source combination reporter emission factor, EFs,m (standard cubic feet per hour) [98.236(p)(3)(ii)(B)] | 0.6671429 |
Total number of compressors measured in the compressor mode-source combination in current reporting year and preceding two reporting years, Countm [98.236(p)(3)(ii)(C)] | 21 |
Is the reporter emission factor facility-specific or based on all of the reporter's applicable facilities? [98.236(p)(3)(ii)(D)] | All applicable facilities |
Compressor Mode [98.236(p)(3)(ii)(A)] | Not-operating-depressurized |
Compressor Source [98.236(p)(3)(ii)(A)] | Isolation valve |
Compressor mode-source combination reporter emission factor, EFs,m (standard cubic feet per hour) [98.236(p)(3)(ii)(B)] | 16.222 |
Total number of compressors measured in the compressor mode-source combination in current reporting year and preceding two reporting years, Countm [98.236(p)(3)(ii)(C)] | 28 |
Is the reporter emission factor facility-specific or based on all of the reporter's applicable facilities? [98.236(p)(3)(ii)(D)] | All applicable facilities |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | Cat 3001 BDV |
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)] | Single |
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)] | Atmosphere |
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)] | Yes |
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)] | No |
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)] | 0.0001142 |
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)] | 0.0070165 |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | Cat 3001 ISO |
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)] | Single |
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)] | Atmosphere |
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)] | No |
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)] | No |
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)] | 0.0005559 |
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)] | 0.0341659 |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | Cat 3001 RPV |
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)] | Single |
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)] | Atmosphere |
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)] | Yes |
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)] | No |
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)] | 0.0464295 |
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)] | 2.8538013 |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | Cat 3002 BDV |
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)] | Single |
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)] | Atmosphere |
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)] | Yes |
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)] | No |
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)] | 0.0001136 |
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)] | 0.0069828 |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | Cat 3002 ISO |
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)] | Single |
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)] | Atmosphere |
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)] | No |
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)] | No |
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)] | 0.0003913 |
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)] | 0.0240528 |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | Cat 3002 RPV |
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)] | Single |
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)] | Atmosphere |
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)] | Yes |
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)] | No |
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)] | 0.2073743 |
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)] | 12.7463113 |
Component Type [98.236(q)(2)(i)] | Compressor Components, Gas Service - Valve |
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)] | 1 |
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)] | 8784 |
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)] | 0.0356546 |
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)] | 2.1964639 |
Component Type [98.236(q)(2)(i)] | Compressor Components, Gas Service - Connector |
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)] | 1 |
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)] | 8784 |
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)] | 0.0134305 |
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)] | 0.8273742 |
Component Type [98.236(q)(2)(i)] | Compressor Components, Gas Service - Open-ended Line |
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)] | 0 |
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)] | 0 |
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)] | 0 |
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)] | 0 |
Component Type [98.236(q)(2)(i)] | Compressor Components, Gas Service - Pressure Relief Valve |
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)] | 0 |
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)] | 0 |
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)] | 0 |
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)] | 0 |
Component Type [98.236(q)(2)(i)] | Compressor Components, Gas Service - Meter |
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)] | 0 |
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)] | 0 |
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)] | 0 |
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)] | 0 |
Component Type [98.236(q)(2)(i)] | Non-Compressor Components, Gas Service - Valve |
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)] | 2 |
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)] | 8784 |
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)] | 0.0308494 |
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)] | 1.9004445 |
Component Type [98.236(q)(2)(i)] | Non-Compressor Components, Gas Service - Connector |
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)] | 1 |
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)] | 8784 |
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)] | 0.0137188 |
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)] | 0.8451354 |
Component Type [98.236(q)(2)(i)] | Non-Compressor Components, Gas Service - Open-ended Line |
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)] | 0 |
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)] | 0 |
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)] | 0 |
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)] | 0 |
Component Type [98.236(q)(2)(i)] | Non-Compressor components, Gas Service - Pressure Relief Valve |
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)] | 1 |
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)] | 8784 |
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)] | 0.0048292 |
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)] | 0.2974995 |
Component Type [98.236(q)(2)(i)] | Non-Compressor components, Gas Service - Meter |
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)] | 0 |
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)] | 0 |
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)] | 0 |
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)] | 0 |