Ventilation Monitoring Point that corresponds to centralized monitoring point or individual shaft from previous tab [§98.326(l)] | Twentymile Zero Entry Fan |
Quarter | 1 |
Dates where active ventilation of mining operations is taking place (MM/DD/YYYY) [§98.326(l)] - Start date | 2020-01-01 |
Stop date | 2020-01-31 |
Method used for flow rate [§98.326(f), (r), (s)] | Monitored using 98.324(b)(1) |
V - Quarterly volumetric flow rate used in Eq. FF-1 (acfm or scfm per selection in column A7) [§98.326(f)] | 298400 |
Specify units for parameter V, quarterly volumetric flow rate [§98.326(f)] | acfm |
Length of time that substitute data are used for the quarterly volumetric flow rate used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(f)] | 0 |
Location of each measurement of flow rate used in Eq. FF-1 [§98.326(f)] | Twentymile Zero Entry Fan |
Date of each measurement of flow rate used in Eq. FF-1 (MM/DD/YYYY) [§98.326(f)] | 2020-01-23 |
Dates when continuous monitoring equipment for the flow rate is not properly functioning, if applicable (MM/DD/YYYY) [§98.326(n)] - Start date | |
Stop date | |
Method used for concentration [§98.326(g), (r), (s)] | Monitored using 98.324(b)(1) |
C - Quarterly CH4 concentration used in Eq. FF-1 (volume %) [§98.326(g)] | 0 |
Was Eq. FF-9 required to calculate CH4 concentration? [§98.326(o)] | No |
If yes, provide the gaseous organic concentration correction factor, used in Eq. FF-9 [§98.326(o)] | |
Length of time that substitute data are used for the quarterly CH4 concentration (hours) [§98.3(c)(8), §98.326(g)] | 0 |
Location of each measurement of concentration [§98.326(g)] | Twentymile Zero Entry Fan |
Date of each measurement of concentration (MM/DD/YYYY) [§98.326(g)] | 2020-01-23 |
Dates when continuous monitoring equipment for the concentration is not properly functioning, if applicable (MM/DD/YYYY) [§98.326(n)] - Start date | |
Stop date | |
T - Temperature used in Eq. FF-1 (°R) [§98.326(o)] | 511.37 |
Length of time that substitute data are used for the temperature used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(o)] | 0 |
P - Absolute Pressure used in Eq. FF-1 (atm) [§98.326(o)] | 0.78 |
Length of time that substitute data are used for the pressure used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(o)] | 0 |
Were the Quarterly Ventilation Flow Rate and Quarterly CH4 Concentration measured on the same basis? [§98.326(f)-(g)] | Flow rate was measured on a wet basis and CH4 concentration was measured on a dry basis |
Was a flow meter used? [§98.326(f)-(g)] | A flow meter was not used |
fH2O - Moisture content used in Eq. FF-1 (cubic feet water per cubic feet biogas) [§98.326(o)] | 0.0073 |
Length of time that substitute data are used for the moisture content used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(o)] | 0 |
Moisture correction factor used in Eq. FF-1 [§98.326(o)] | 0.9927 |
Length of time that substitute data are used for the moisture correction factor used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(o)] | 0 |
CH4V - Quarterly CH4 liberated from ventilation monitoring point (MT CH4) [§98.326(a)] --- Output of Eq. FF-1 | 0 |
File name of MSHA report used to report quarterly CH4 concentration and volumetric flow rate [§98.326(a)] | |
Ventilation Monitoring Point that corresponds to centralized monitoring point or individual shaft from previous tab [§98.326(l)] | Twentymile Five Main North Fan |
Quarter | 1 |
Dates where active ventilation of mining operations is taking place (MM/DD/YYYY) [§98.326(l)] - Start date | 2020-01-01 |
Stop date | 2020-01-31 |
Method used for flow rate [§98.326(f), (r), (s)] | Monitored using 98.324(b)(1) |
V - Quarterly volumetric flow rate used in Eq. FF-1 (acfm or scfm per selection in column A7) [§98.326(f)] | 965900 |
Specify units for parameter V, quarterly volumetric flow rate [§98.326(f)] | acfm |
Length of time that substitute data are used for the quarterly volumetric flow rate used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(f)] | 0 |
Location of each measurement of flow rate used in Eq. FF-1 [§98.326(f)] | Twentymile Five Main North Fan |
Date of each measurement of flow rate used in Eq. FF-1 (MM/DD/YYYY) [§98.326(f)] | 2020-01-23 |
Dates when continuous monitoring equipment for the flow rate is not properly functioning, if applicable (MM/DD/YYYY) [§98.326(n)] - Start date | |
Stop date | |
Method used for concentration [§98.326(g), (r), (s)] | Monitored using 98.324(b)(1) |
C - Quarterly CH4 concentration used in Eq. FF-1 (volume %) [§98.326(g)] | 0.0115 |
Was Eq. FF-9 required to calculate CH4 concentration? [§98.326(o)] | No |
If yes, provide the gaseous organic concentration correction factor, used in Eq. FF-9 [§98.326(o)] | |
Length of time that substitute data are used for the quarterly CH4 concentration (hours) [§98.3(c)(8), §98.326(g)] | 0 |
Location of each measurement of concentration [§98.326(g)] | Twentymile Five Main North Fan |
Date of each measurement of concentration (MM/DD/YYYY) [§98.326(g)] | 2020-01-23 |
Dates when continuous monitoring equipment for the concentration is not properly functioning, if applicable (MM/DD/YYYY) [§98.326(n)] - Start date | |
Stop date | |
T - Temperature used in Eq. FF-1 (°R) [§98.326(o)] | 522.67 |
Length of time that substitute data are used for the temperature used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(o)] | 0 |
P - Absolute Pressure used in Eq. FF-1 (atm) [§98.326(o)] | 0.79 |
Length of time that substitute data are used for the pressure used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(o)] | 0 |
Were the Quarterly Ventilation Flow Rate and Quarterly CH4 Concentration measured on the same basis? [§98.326(f)-(g)] | Flow rate was measured on a wet basis and CH4 concentration was measured on a dry basis |
Was a flow meter used? [§98.326(f)-(g)] | A flow meter was not used |
fH2O - Moisture content used in Eq. FF-1 (cubic feet water per cubic feet biogas) [§98.326(o)] | 0.0133 |
Length of time that substitute data are used for the moisture content used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(o)] | 0 |
Moisture correction factor used in Eq. FF-1 [§98.326(o)] | 0.9867 |
Length of time that substitute data are used for the moisture correction factor used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(o)] | 0 |
CH4V - Quarterly CH4 liberated from ventilation monitoring point (MT CH4) [§98.326(a)] --- Output of Eq. FF-1 | 73.64 |
File name of MSHA report used to report quarterly CH4 concentration and volumetric flow rate [§98.326(a)] | |
Ventilation Monitoring Point that corresponds to centralized monitoring point or individual shaft from previous tab [§98.326(l)] | 9E Exhauster |
Quarter | 1 |
Dates where active ventilation of mining operations is taking place (MM/DD/YYYY) [§98.326(l)] - Start date | 2020-01-01 |
Stop date | 2020-01-31 |
Method used for flow rate [§98.326(f), (r), (s)] | Monitored using 98.324(b)(1) |
V - Quarterly volumetric flow rate used in Eq. FF-1 (acfm or scfm per selection in column A7) [§98.326(f)] | 8800 |
Specify units for parameter V, quarterly volumetric flow rate [§98.326(f)] | acfm |
Length of time that substitute data are used for the quarterly volumetric flow rate used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(f)] | 0 |
Location of each measurement of flow rate used in Eq. FF-1 [§98.326(f)] | 9E Exhauster |
Date of each measurement of flow rate used in Eq. FF-1 (MM/DD/YYYY) [§98.326(f)] | 2020-01-23 |
Dates when continuous monitoring equipment for the flow rate is not properly functioning, if applicable (MM/DD/YYYY) [§98.326(n)] - Start date | |
Stop date | |
Method used for concentration [§98.326(g), (r), (s)] | Monitored using 98.324(b)(1) |
C - Quarterly CH4 concentration used in Eq. FF-1 (volume %) [§98.326(g)] | 0.5884 |
Was Eq. FF-9 required to calculate CH4 concentration? [§98.326(o)] | No |
If yes, provide the gaseous organic concentration correction factor, used in Eq. FF-9 [§98.326(o)] | |
Length of time that substitute data are used for the quarterly CH4 concentration (hours) [§98.3(c)(8), §98.326(g)] | 0 |
Location of each measurement of concentration [§98.326(g)] | 9E Exhauster |
Date of each measurement of concentration (MM/DD/YYYY) [§98.326(g)] | 2020-01-23 |
Dates when continuous monitoring equipment for the concentration is not properly functioning, if applicable (MM/DD/YYYY) [§98.326(n)] - Start date | |
Stop date | |
T - Temperature used in Eq. FF-1 (°R) [§98.326(o)] | 514.47 |
Length of time that substitute data are used for the temperature used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(o)] | 0 |
P - Absolute Pressure used in Eq. FF-1 (atm) [§98.326(o)] | 0.79 |
Length of time that substitute data are used for the pressure used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(o)] | 0 |
Were the Quarterly Ventilation Flow Rate and Quarterly CH4 Concentration measured on the same basis? [§98.326(f)-(g)] | Flow rate was measured on a wet basis and CH4 concentration was measured on a dry basis |
Was a flow meter used? [§98.326(f)-(g)] | A flow meter was not used |
fH2O - Moisture content used in Eq. FF-1 (cubic feet water per cubic feet biogas) [§98.326(o)] | 0.0059 |
Length of time that substitute data are used for the moisture content used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(o)] | 0 |
Moisture correction factor used in Eq. FF-1 [§98.326(o)] | 0.9941 |
Length of time that substitute data are used for the moisture correction factor used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(o)] | 0 |
CH4V - Quarterly CH4 liberated from ventilation monitoring point (MT CH4) [§98.326(a)] --- Output of Eq. FF-1 | 35.02 |
File name of MSHA report used to report quarterly CH4 concentration and volumetric flow rate [§98.326(a)] | |
Ventilation Monitoring Point that corresponds to centralized monitoring point or individual shaft from previous tab [§98.326(l)] | Twentymile Zero Entry Fan |
Quarter | 1 |
Dates where active ventilation of mining operations is taking place (MM/DD/YYYY) [§98.326(l)] - Start date | 2020-02-01 |
Stop date | 2020-02-29 |
Method used for flow rate [§98.326(f), (r), (s)] | Monitored using 98.324(b)(1) |
V - Quarterly volumetric flow rate used in Eq. FF-1 (acfm or scfm per selection in column A7) [§98.326(f)] | 270600 |
Specify units for parameter V, quarterly volumetric flow rate [§98.326(f)] | acfm |
Length of time that substitute data are used for the quarterly volumetric flow rate used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(f)] | 0 |
Location of each measurement of flow rate used in Eq. FF-1 [§98.326(f)] | Twentymile Zero Entry Fan |
Date of each measurement of flow rate used in Eq. FF-1 (MM/DD/YYYY) [§98.326(f)] | 2020-02-26 |
Dates when continuous monitoring equipment for the flow rate is not properly functioning, if applicable (MM/DD/YYYY) [§98.326(n)] - Start date | |
Stop date | |
Method used for concentration [§98.326(g), (r), (s)] | Monitored using 98.324(b)(1) |
C - Quarterly CH4 concentration used in Eq. FF-1 (volume %) [§98.326(g)] | 0.0045 |
Was Eq. FF-9 required to calculate CH4 concentration? [§98.326(o)] | No |
If yes, provide the gaseous organic concentration correction factor, used in Eq. FF-9 [§98.326(o)] | |
Length of time that substitute data are used for the quarterly CH4 concentration (hours) [§98.3(c)(8), §98.326(g)] | 0 |
Location of each measurement of concentration [§98.326(g)] | Twentymile Zero Entry Fan |
Date of each measurement of concentration (MM/DD/YYYY) [§98.326(g)] | 2020-02-26 |
Dates when continuous monitoring equipment for the concentration is not properly functioning, if applicable (MM/DD/YYYY) [§98.326(n)] - Start date | |
Stop date | |
T - Temperature used in Eq. FF-1 (°R) [§98.326(o)] | 504.07 |
Length of time that substitute data are used for the temperature used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(o)] | 0 |
P - Absolute Pressure used in Eq. FF-1 (atm) [§98.326(o)] | 0.79 |
Length of time that substitute data are used for the pressure used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(o)] | 0 |
Were the Quarterly Ventilation Flow Rate and Quarterly CH4 Concentration measured on the same basis? [§98.326(f)-(g)] | Flow rate was measured on a wet basis and CH4 concentration was measured on a dry basis |
Was a flow meter used? [§98.326(f)-(g)] | A flow meter was not used |
fH2O - Moisture content used in Eq. FF-1 (cubic feet water per cubic feet biogas) [§98.326(o)] | 0.0053 |
Length of time that substitute data are used for the moisture content used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(o)] | 0 |
Moisture correction factor used in Eq. FF-1 [§98.326(o)] | 0.9947 |
Length of time that substitute data are used for the moisture correction factor used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(o)] | 0 |
CH4V - Quarterly CH4 liberated from ventilation monitoring point (MT CH4) [§98.326(a)] --- Output of Eq. FF-1 | 7.89 |
File name of MSHA report used to report quarterly CH4 concentration and volumetric flow rate [§98.326(a)] | |
Ventilation Monitoring Point that corresponds to centralized monitoring point or individual shaft from previous tab [§98.326(l)] | Twentymile Five Main North Fan |
Quarter | 1 |
Dates where active ventilation of mining operations is taking place (MM/DD/YYYY) [§98.326(l)] - Start date | 2020-02-01 |
Stop date | 2020-02-29 |
Method used for flow rate [§98.326(f), (r), (s)] | Monitored using 98.324(b)(1) |
V - Quarterly volumetric flow rate used in Eq. FF-1 (acfm or scfm per selection in column A7) [§98.326(f)] | 937700 |
Specify units for parameter V, quarterly volumetric flow rate [§98.326(f)] | acfm |
Length of time that substitute data are used for the quarterly volumetric flow rate used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(f)] | 0 |
Location of each measurement of flow rate used in Eq. FF-1 [§98.326(f)] | Twentymile Five Main North Fan |
Date of each measurement of flow rate used in Eq. FF-1 (MM/DD/YYYY) [§98.326(f)] | 2020-02-26 |
Dates when continuous monitoring equipment for the flow rate is not properly functioning, if applicable (MM/DD/YYYY) [§98.326(n)] - Start date | |
Stop date | |
Method used for concentration [§98.326(g), (r), (s)] | Monitored using 98.324(b)(1) |
C - Quarterly CH4 concentration used in Eq. FF-1 (volume %) [§98.326(g)] | 0.0055 |
Was Eq. FF-9 required to calculate CH4 concentration? [§98.326(o)] | No |
If yes, provide the gaseous organic concentration correction factor, used in Eq. FF-9 [§98.326(o)] | |
Length of time that substitute data are used for the quarterly CH4 concentration (hours) [§98.3(c)(8), §98.326(g)] | 0 |
Location of each measurement of concentration [§98.326(g)] | Twentymile Five Main North Fan |
Date of each measurement of concentration (MM/DD/YYYY) [§98.326(g)] | 2020-02-26 |
Dates when continuous monitoring equipment for the concentration is not properly functioning, if applicable (MM/DD/YYYY) [§98.326(n)] - Start date | |
Stop date | |
T - Temperature used in Eq. FF-1 (°R) [§98.326(o)] | 510.27 |
Length of time that substitute data are used for the temperature used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(o)] | 0 |
P - Absolute Pressure used in Eq. FF-1 (atm) [§98.326(o)] | 0.79 |
Length of time that substitute data are used for the pressure used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(o)] | 0 |
Were the Quarterly Ventilation Flow Rate and Quarterly CH4 Concentration measured on the same basis? [§98.326(f)-(g)] | Flow rate was measured on a wet basis and CH4 concentration was measured on a dry basis |
Was a flow meter used? [§98.326(f)-(g)] | A flow meter was not used |
fH2O - Moisture content used in Eq. FF-1 (cubic feet water per cubic feet biogas) [§98.326(o)] | 0.0083 |
Length of time that substitute data are used for the moisture content used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(o)] | 0 |
Moisture correction factor used in Eq. FF-1 [§98.326(o)] | 0.9917 |
Length of time that substitute data are used for the moisture correction factor used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(o)] | 0 |
CH4V - Quarterly CH4 liberated from ventilation monitoring point (MT CH4) [§98.326(a)] --- Output of Eq. FF-1 | 32.96 |
File name of MSHA report used to report quarterly CH4 concentration and volumetric flow rate [§98.326(a)] | |
Ventilation Monitoring Point that corresponds to centralized monitoring point or individual shaft from previous tab [§98.326(l)] | 9E Exhauster |
Quarter | 1 |
Dates where active ventilation of mining operations is taking place (MM/DD/YYYY) [§98.326(l)] - Start date | 2020-02-01 |
Stop date | 2020-02-29 |
Method used for flow rate [§98.326(f), (r), (s)] | Monitored using 98.324(b)(1) |
V - Quarterly volumetric flow rate used in Eq. FF-1 (acfm or scfm per selection in column A7) [§98.326(f)] | 8200 |
Specify units for parameter V, quarterly volumetric flow rate [§98.326(f)] | acfm |
Length of time that substitute data are used for the quarterly volumetric flow rate used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(f)] | 0 |
Location of each measurement of flow rate used in Eq. FF-1 [§98.326(f)] | 9E Exhauster |
Date of each measurement of flow rate used in Eq. FF-1 (MM/DD/YYYY) [§98.326(f)] | 2020-02-26 |
Dates when continuous monitoring equipment for the flow rate is not properly functioning, if applicable (MM/DD/YYYY) [§98.326(n)] - Start date | |
Stop date | |
Method used for concentration [§98.326(g), (r), (s)] | Monitored using 98.324(b)(1) |
C - Quarterly CH4 concentration used in Eq. FF-1 (volume %) [§98.326(g)] | 0.0299 |
Was Eq. FF-9 required to calculate CH4 concentration? [§98.326(o)] | No |
If yes, provide the gaseous organic concentration correction factor, used in Eq. FF-9 [§98.326(o)] | |
Length of time that substitute data are used for the quarterly CH4 concentration (hours) [§98.3(c)(8), §98.326(g)] | 0 |
Location of each measurement of concentration [§98.326(g)] | 9E Exhauster |
Date of each measurement of concentration (MM/DD/YYYY) [§98.326(g)] | 2020-02-26 |
Dates when continuous monitoring equipment for the concentration is not properly functioning, if applicable (MM/DD/YYYY) [§98.326(n)] - Start date | |
Stop date | |
T - Temperature used in Eq. FF-1 (°R) [§98.326(o)] | 510.87 |
Length of time that substitute data are used for the temperature used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(o)] | 0 |
P - Absolute Pressure used in Eq. FF-1 (atm) [§98.326(o)] | 0.79 |
Length of time that substitute data are used for the pressure used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(o)] | 0 |
Were the Quarterly Ventilation Flow Rate and Quarterly CH4 Concentration measured on the same basis? [§98.326(f)-(g)] | Flow rate was measured on a wet basis and CH4 concentration was measured on a dry basis |
Was a flow meter used? [§98.326(f)-(g)] | A flow meter was not used |
fH2O - Moisture content used in Eq. FF-1 (cubic feet water per cubic feet biogas) [§98.326(o)] | 0.0026 |
Length of time that substitute data are used for the moisture content used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(o)] | 0 |
Moisture correction factor used in Eq. FF-1 [§98.326(o)] | 0.9974 |
Length of time that substitute data are used for the moisture correction factor used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(o)] | 0 |
CH4V - Quarterly CH4 liberated from ventilation monitoring point (MT CH4) [§98.326(a)] --- Output of Eq. FF-1 | 1.58 |
File name of MSHA report used to report quarterly CH4 concentration and volumetric flow rate [§98.326(a)] | |
Ventilation Monitoring Point that corresponds to centralized monitoring point or individual shaft from previous tab [§98.326(l)] | Twentymile Zero Entry Fan |
Quarter | 1 |
Dates where active ventilation of mining operations is taking place (MM/DD/YYYY) [§98.326(l)] - Start date | 2020-03-01 |
Stop date | 2020-03-31 |
Method used for flow rate [§98.326(f), (r), (s)] | Monitored using 98.324(b)(1) |
V - Quarterly volumetric flow rate used in Eq. FF-1 (acfm or scfm per selection in column A7) [§98.326(f)] | 270400 |
Specify units for parameter V, quarterly volumetric flow rate [§98.326(f)] | acfm |
Length of time that substitute data are used for the quarterly volumetric flow rate used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(f)] | 0 |
Location of each measurement of flow rate used in Eq. FF-1 [§98.326(f)] | Twentymile Zero Entry Fan |
Date of each measurement of flow rate used in Eq. FF-1 (MM/DD/YYYY) [§98.326(f)] | 2020-03-26 |
Dates when continuous monitoring equipment for the flow rate is not properly functioning, if applicable (MM/DD/YYYY) [§98.326(n)] - Start date | |
Stop date | |
Method used for concentration [§98.326(g), (r), (s)] | Monitored using 98.324(b)(1) |
C - Quarterly CH4 concentration used in Eq. FF-1 (volume %) [§98.326(g)] | 0.0048 |
Was Eq. FF-9 required to calculate CH4 concentration? [§98.326(o)] | No |
If yes, provide the gaseous organic concentration correction factor, used in Eq. FF-9 [§98.326(o)] | |
Length of time that substitute data are used for the quarterly CH4 concentration (hours) [§98.3(c)(8), §98.326(g)] | 0 |
Location of each measurement of concentration [§98.326(g)] | Twentymile Zero Entry Fan |
Date of each measurement of concentration (MM/DD/YYYY) [§98.326(g)] | 2020-03-26 |
Dates when continuous monitoring equipment for the concentration is not properly functioning, if applicable (MM/DD/YYYY) [§98.326(n)] - Start date | |
Stop date | |
T - Temperature used in Eq. FF-1 (°R) [§98.326(o)] | 513.87 |
Length of time that substitute data are used for the temperature used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(o)] | 0 |
P - Absolute Pressure used in Eq. FF-1 (atm) [§98.326(o)] | 0.77 |
Length of time that substitute data are used for the pressure used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(o)] | 0 |
Were the Quarterly Ventilation Flow Rate and Quarterly CH4 Concentration measured on the same basis? [§98.326(f)-(g)] | Flow rate was measured on a wet basis and CH4 concentration was measured on a dry basis |
Was a flow meter used? [§98.326(f)-(g)] | A flow meter was not used |
fH2O - Moisture content used in Eq. FF-1 (cubic feet water per cubic feet biogas) [§98.326(o)] | 0.007 |
Length of time that substitute data are used for the moisture content used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(o)] | 0 |
Moisture correction factor used in Eq. FF-1 [§98.326(o)] | 0.993 |
Length of time that substitute data are used for the moisture correction factor used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(o)] | 0 |
CH4V - Quarterly CH4 liberated from ventilation monitoring point (MT CH4) [§98.326(a)] --- Output of Eq. FF-1 | 8.6 |
File name of MSHA report used to report quarterly CH4 concentration and volumetric flow rate [§98.326(a)] | |
Ventilation Monitoring Point that corresponds to centralized monitoring point or individual shaft from previous tab [§98.326(l)] | Twentymile Five Main North Fan |
Quarter | 1 |
Dates where active ventilation of mining operations is taking place (MM/DD/YYYY) [§98.326(l)] - Start date | 2020-03-01 |
Stop date | 2020-03-31 |
Method used for flow rate [§98.326(f), (r), (s)] | Monitored using 98.324(b)(1) |
V - Quarterly volumetric flow rate used in Eq. FF-1 (acfm or scfm per selection in column A7) [§98.326(f)] | 957500 |
Specify units for parameter V, quarterly volumetric flow rate [§98.326(f)] | acfm |
Length of time that substitute data are used for the quarterly volumetric flow rate used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(f)] | 0 |
Location of each measurement of flow rate used in Eq. FF-1 [§98.326(f)] | Twentymile Five Main North Fan |
Date of each measurement of flow rate used in Eq. FF-1 (MM/DD/YYYY) [§98.326(f)] | 2020-03-26 |
Dates when continuous monitoring equipment for the flow rate is not properly functioning, if applicable (MM/DD/YYYY) [§98.326(n)] - Start date | |
Stop date | |
Method used for concentration [§98.326(g), (r), (s)] | Monitored using 98.324(b)(1) |
C - Quarterly CH4 concentration used in Eq. FF-1 (volume %) [§98.326(g)] | 0.0058 |
Was Eq. FF-9 required to calculate CH4 concentration? [§98.326(o)] | No |
If yes, provide the gaseous organic concentration correction factor, used in Eq. FF-9 [§98.326(o)] | |
Length of time that substitute data are used for the quarterly CH4 concentration (hours) [§98.3(c)(8), §98.326(g)] | 0 |
Location of each measurement of concentration [§98.326(g)] | Twentymile Five Main North Fan |
Date of each measurement of concentration (MM/DD/YYYY) [§98.326(g)] | 2020-03-26 |
Dates when continuous monitoring equipment for the concentration is not properly functioning, if applicable (MM/DD/YYYY) [§98.326(n)] - Start date | |
Stop date | |
T - Temperature used in Eq. FF-1 (°R) [§98.326(o)] | 526.67 |
Length of time that substitute data are used for the temperature used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(o)] | 0 |
P - Absolute Pressure used in Eq. FF-1 (atm) [§98.326(o)] | 0.77 |
Length of time that substitute data are used for the pressure used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(o)] | 0 |
Were the Quarterly Ventilation Flow Rate and Quarterly CH4 Concentration measured on the same basis? [§98.326(f)-(g)] | Flow rate was measured on a wet basis and CH4 concentration was measured on a dry basis |
Was a flow meter used? [§98.326(f)-(g)] | A flow meter was not used |
fH2O - Moisture content used in Eq. FF-1 (cubic feet water per cubic feet biogas) [§98.326(o)] | 0.0095 |
Length of time that substitute data are used for the moisture content used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(o)] | 0 |
Moisture correction factor used in Eq. FF-1 [§98.326(o)] | 0.9905 |
Length of time that substitute data are used for the moisture correction factor used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(o)] | 0 |
CH4V - Quarterly CH4 liberated from ventilation monitoring point (MT CH4) [§98.326(a)] --- Output of Eq. FF-1 | 36.02 |
File name of MSHA report used to report quarterly CH4 concentration and volumetric flow rate [§98.326(a)] | |
Ventilation Monitoring Point that corresponds to centralized monitoring point or individual shaft from previous tab [§98.326(l)] | 9E Exhauster |
Quarter | 1 |
Dates where active ventilation of mining operations is taking place (MM/DD/YYYY) [§98.326(l)] - Start date | 2020-03-01 |
Stop date | 2020-03-31 |
Method used for flow rate [§98.326(f), (r), (s)] | Monitored using 98.324(b)(1) |
V - Quarterly volumetric flow rate used in Eq. FF-1 (acfm or scfm per selection in column A7) [§98.326(f)] | 9100 |
Specify units for parameter V, quarterly volumetric flow rate [§98.326(f)] | acfm |
Length of time that substitute data are used for the quarterly volumetric flow rate used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(f)] | 0 |
Location of each measurement of flow rate used in Eq. FF-1 [§98.326(f)] | 9E Exhauster |
Date of each measurement of flow rate used in Eq. FF-1 (MM/DD/YYYY) [§98.326(f)] | 2020-03-26 |
Dates when continuous monitoring equipment for the flow rate is not properly functioning, if applicable (MM/DD/YYYY) [§98.326(n)] - Start date | |
Stop date | |
Method used for concentration [§98.326(g), (r), (s)] | Monitored using 98.324(b)(1) |
C - Quarterly CH4 concentration used in Eq. FF-1 (volume %) [§98.326(g)] | 1.5103 |
Was Eq. FF-9 required to calculate CH4 concentration? [§98.326(o)] | No |
If yes, provide the gaseous organic concentration correction factor, used in Eq. FF-9 [§98.326(o)] | |
Length of time that substitute data are used for the quarterly CH4 concentration (hours) [§98.3(c)(8), §98.326(g)] | 0 |
Location of each measurement of concentration [§98.326(g)] | 9E Exhauster |
Date of each measurement of concentration (MM/DD/YYYY) [§98.326(g)] | 2020-03-26 |
Dates when continuous monitoring equipment for the concentration is not properly functioning, if applicable (MM/DD/YYYY) [§98.326(n)] - Start date | |
Stop date | |
T - Temperature used in Eq. FF-1 (°R) [§98.326(o)] | 521.97 |
Length of time that substitute data are used for the temperature used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(o)] | 0 |
P - Absolute Pressure used in Eq. FF-1 (atm) [§98.326(o)] | 0.77 |
Length of time that substitute data are used for the pressure used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(o)] | 0 |
Were the Quarterly Ventilation Flow Rate and Quarterly CH4 Concentration measured on the same basis? [§98.326(f)-(g)] | Flow rate was measured on a wet basis and CH4 concentration was measured on a dry basis |
Was a flow meter used? [§98.326(f)-(g)] | A flow meter was not used |
fH2O - Moisture content used in Eq. FF-1 (cubic feet water per cubic feet biogas) [§98.326(o)] | 0.0033 |
Length of time that substitute data are used for the moisture content used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(o)] | 0 |
Moisture correction factor used in Eq. FF-1 [§98.326(o)] | 0.9967 |
Length of time that substitute data are used for the moisture correction factor used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(o)] | 0 |
CH4V - Quarterly CH4 liberated from ventilation monitoring point (MT CH4) [§98.326(a)] --- Output of Eq. FF-1 | 90.28 |
File name of MSHA report used to report quarterly CH4 concentration and volumetric flow rate [§98.326(a)] | |
Ventilation Monitoring Point that corresponds to centralized monitoring point or individual shaft from previous tab [§98.326(l)] | Twentymile Zero Entry Fan |
Quarter | 2 |
Dates where active ventilation of mining operations is taking place (MM/DD/YYYY) [§98.326(l)] - Start date | 2020-04-01 |
Stop date | 2020-04-30 |
Method used for flow rate [§98.326(f), (r), (s)] | Monitored using 98.324(b)(1) |
V - Quarterly volumetric flow rate used in Eq. FF-1 (acfm or scfm per selection in column A7) [§98.326(f)] | 261800 |
Specify units for parameter V, quarterly volumetric flow rate [§98.326(f)] | acfm |
Length of time that substitute data are used for the quarterly volumetric flow rate used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(f)] | 0 |
Location of each measurement of flow rate used in Eq. FF-1 [§98.326(f)] | Twentymile Zero Entry Fan |
Date of each measurement of flow rate used in Eq. FF-1 (MM/DD/YYYY) [§98.326(f)] | 2020-04-22 |
Dates when continuous monitoring equipment for the flow rate is not properly functioning, if applicable (MM/DD/YYYY) [§98.326(n)] - Start date | |
Stop date | |
Method used for concentration [§98.326(g), (r), (s)] | Monitored using 98.324(b)(1) |
C - Quarterly CH4 concentration used in Eq. FF-1 (volume %) [§98.326(g)] | 0.0139 |
Was Eq. FF-9 required to calculate CH4 concentration? [§98.326(o)] | No |
If yes, provide the gaseous organic concentration correction factor, used in Eq. FF-9 [§98.326(o)] | |
Length of time that substitute data are used for the quarterly CH4 concentration (hours) [§98.3(c)(8), §98.326(g)] | 0 |
Location of each measurement of concentration [§98.326(g)] | Twentymile Zero Entry Fan |
Date of each measurement of concentration (MM/DD/YYYY) [§98.326(g)] | 2020-04-22 |
Dates when continuous monitoring equipment for the concentration is not properly functioning, if applicable (MM/DD/YYYY) [§98.326(n)] - Start date | |
Stop date | |
T - Temperature used in Eq. FF-1 (°R) [§98.326(o)] | 515.17 |
Length of time that substitute data are used for the temperature used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(o)] | 0 |
P - Absolute Pressure used in Eq. FF-1 (atm) [§98.326(o)] | 0.78 |
Length of time that substitute data are used for the pressure used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(o)] | 0 |
Were the Quarterly Ventilation Flow Rate and Quarterly CH4 Concentration measured on the same basis? [§98.326(f)-(g)] | Flow rate was measured on a wet basis and CH4 concentration was measured on a dry basis |
Was a flow meter used? [§98.326(f)-(g)] | A flow meter was not used |
fH2O - Moisture content used in Eq. FF-1 (cubic feet water per cubic feet biogas) [§98.326(o)] | 0.0072 |
Length of time that substitute data are used for the moisture content used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(o)] | 0 |
Moisture correction factor used in Eq. FF-1 [§98.326(o)] | 0.9928 |
Length of time that substitute data are used for the moisture correction factor used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(o)] | 0 |
CH4V - Quarterly CH4 liberated from ventilation monitoring point (MT CH4) [§98.326(a)] --- Output of Eq. FF-1 | 23.6 |
File name of MSHA report used to report quarterly CH4 concentration and volumetric flow rate [§98.326(a)] | |
Ventilation Monitoring Point that corresponds to centralized monitoring point or individual shaft from previous tab [§98.326(l)] | Twentymile Five Main North Fan |
Quarter | 2 |
Dates where active ventilation of mining operations is taking place (MM/DD/YYYY) [§98.326(l)] - Start date | 2020-04-01 |
Stop date | 2020-04-30 |
Method used for flow rate [§98.326(f), (r), (s)] | Monitored using 98.324(b)(1) |
V - Quarterly volumetric flow rate used in Eq. FF-1 (acfm or scfm per selection in column A7) [§98.326(f)] | 992600 |
Specify units for parameter V, quarterly volumetric flow rate [§98.326(f)] | acfm |
Length of time that substitute data are used for the quarterly volumetric flow rate used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(f)] | 0 |
Location of each measurement of flow rate used in Eq. FF-1 [§98.326(f)] | Twentymile Five Main North Fan |
Date of each measurement of flow rate used in Eq. FF-1 (MM/DD/YYYY) [§98.326(f)] | 2020-04-22 |
Dates when continuous monitoring equipment for the flow rate is not properly functioning, if applicable (MM/DD/YYYY) [§98.326(n)] - Start date | |
Stop date | |
Method used for concentration [§98.326(g), (r), (s)] | Monitored using 98.324(b)(1) |
C - Quarterly CH4 concentration used in Eq. FF-1 (volume %) [§98.326(g)] | 0.008 |
Was Eq. FF-9 required to calculate CH4 concentration? [§98.326(o)] | No |
If yes, provide the gaseous organic concentration correction factor, used in Eq. FF-9 [§98.326(o)] | |
Length of time that substitute data are used for the quarterly CH4 concentration (hours) [§98.3(c)(8), §98.326(g)] | 0 |
Location of each measurement of concentration [§98.326(g)] | Twentymile Five Main North Fan |
Date of each measurement of concentration (MM/DD/YYYY) [§98.326(g)] | 2020-04-22 |
Dates when continuous monitoring equipment for the concentration is not properly functioning, if applicable (MM/DD/YYYY) [§98.326(n)] - Start date | |
Stop date | |
T - Temperature used in Eq. FF-1 (°R) [§98.326(o)] | 525.77 |
Length of time that substitute data are used for the temperature used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(o)] | 0 |
P - Absolute Pressure used in Eq. FF-1 (atm) [§98.326(o)] | 0.78 |
Length of time that substitute data are used for the pressure used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(o)] | 0 |
Were the Quarterly Ventilation Flow Rate and Quarterly CH4 Concentration measured on the same basis? [§98.326(f)-(g)] | Flow rate was measured on a wet basis and CH4 concentration was measured on a dry basis |
Was a flow meter used? [§98.326(f)-(g)] | A flow meter was not used |
fH2O - Moisture content used in Eq. FF-1 (cubic feet water per cubic feet biogas) [§98.326(o)] | 0.0092 |
Length of time that substitute data are used for the moisture content used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(o)] | 0 |
Moisture correction factor used in Eq. FF-1 [§98.326(o)] | 0.9908 |
Length of time that substitute data are used for the moisture correction factor used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(o)] | 0 |
CH4V - Quarterly CH4 liberated from ventilation monitoring point (MT CH4) [§98.326(a)] --- Output of Eq. FF-1 | 50.64 |
File name of MSHA report used to report quarterly CH4 concentration and volumetric flow rate [§98.326(a)] | |
Ventilation Monitoring Point that corresponds to centralized monitoring point or individual shaft from previous tab [§98.326(l)] | 9E Exhauster |
Quarter | 2 |
Dates where active ventilation of mining operations is taking place (MM/DD/YYYY) [§98.326(l)] - Start date | 2020-04-01 |
Stop date | 2020-04-17 |
Method used for flow rate [§98.326(f), (r), (s)] | Monitored using 98.324(b)(1) |
V - Quarterly volumetric flow rate used in Eq. FF-1 (acfm or scfm per selection in column A7) [§98.326(f)] | 8500 |
Specify units for parameter V, quarterly volumetric flow rate [§98.326(f)] | acfm |
Length of time that substitute data are used for the quarterly volumetric flow rate used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(f)] | 0 |
Location of each measurement of flow rate used in Eq. FF-1 [§98.326(f)] | 9E Exhauster |
Date of each measurement of flow rate used in Eq. FF-1 (MM/DD/YYYY) [§98.326(f)] | 2020-04-17 |
Dates when continuous monitoring equipment for the flow rate is not properly functioning, if applicable (MM/DD/YYYY) [§98.326(n)] - Start date | |
Stop date | |
Method used for concentration [§98.326(g), (r), (s)] | Monitored using 98.324(b)(1) |
C - Quarterly CH4 concentration used in Eq. FF-1 (volume %) [§98.326(g)] | 2.7677 |
Was Eq. FF-9 required to calculate CH4 concentration? [§98.326(o)] | No |
If yes, provide the gaseous organic concentration correction factor, used in Eq. FF-9 [§98.326(o)] | |
Length of time that substitute data are used for the quarterly CH4 concentration (hours) [§98.3(c)(8), §98.326(g)] | 0 |
Location of each measurement of concentration [§98.326(g)] | 9E Exhauster |
Date of each measurement of concentration (MM/DD/YYYY) [§98.326(g)] | 2020-04-17 |
Dates when continuous monitoring equipment for the concentration is not properly functioning, if applicable (MM/DD/YYYY) [§98.326(n)] - Start date | |
Stop date | |
T - Temperature used in Eq. FF-1 (°R) [§98.326(o)] | 521.97 |
Length of time that substitute data are used for the temperature used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(o)] | 0 |
P - Absolute Pressure used in Eq. FF-1 (atm) [§98.326(o)] | 0.77 |
Length of time that substitute data are used for the pressure used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(o)] | 0 |
Were the Quarterly Ventilation Flow Rate and Quarterly CH4 Concentration measured on the same basis? [§98.326(f)-(g)] | Flow rate was measured on a wet basis and CH4 concentration was measured on a dry basis |
Was a flow meter used? [§98.326(f)-(g)] | A flow meter was not used |
fH2O - Moisture content used in Eq. FF-1 (cubic feet water per cubic feet biogas) [§98.326(o)] | 0.0033 |
Length of time that substitute data are used for the moisture content used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(o)] | 0 |
Moisture correction factor used in Eq. FF-1 [§98.326(o)] | 0.9967 |
Length of time that substitute data are used for the moisture correction factor used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(o)] | 0 |
CH4V - Quarterly CH4 liberated from ventilation monitoring point (MT CH4) [§98.326(a)] --- Output of Eq. FF-1 | 84.75 |
File name of MSHA report used to report quarterly CH4 concentration and volumetric flow rate [§98.326(a)] | |
Ventilation Monitoring Point that corresponds to centralized monitoring point or individual shaft from previous tab [§98.326(l)] | Twentymile Zero Entry Fan |
Quarter | 2 |
Dates where active ventilation of mining operations is taking place (MM/DD/YYYY) [§98.326(l)] - Start date | 2020-05-01 |
Stop date | 2020-05-31 |
Method used for flow rate [§98.326(f), (r), (s)] | Monitored using 98.324(b)(1) |
V - Quarterly volumetric flow rate used in Eq. FF-1 (acfm or scfm per selection in column A7) [§98.326(f)] | 259900 |
Specify units for parameter V, quarterly volumetric flow rate [§98.326(f)] | acfm |
Length of time that substitute data are used for the quarterly volumetric flow rate used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(f)] | 0 |
Location of each measurement of flow rate used in Eq. FF-1 [§98.326(f)] | Twentymile Zero Entry Fan |
Date of each measurement of flow rate used in Eq. FF-1 (MM/DD/YYYY) [§98.326(f)] | 2020-05-21 |
Dates when continuous monitoring equipment for the flow rate is not properly functioning, if applicable (MM/DD/YYYY) [§98.326(n)] - Start date | |
Stop date | |
Method used for concentration [§98.326(g), (r), (s)] | Monitored using 98.324(b)(1) |
C - Quarterly CH4 concentration used in Eq. FF-1 (volume %) [§98.326(g)] | 0.0048 |
Was Eq. FF-9 required to calculate CH4 concentration? [§98.326(o)] | No |
If yes, provide the gaseous organic concentration correction factor, used in Eq. FF-9 [§98.326(o)] | |
Length of time that substitute data are used for the quarterly CH4 concentration (hours) [§98.3(c)(8), §98.326(g)] | 0 |
Location of each measurement of concentration [§98.326(g)] | Twentymile Zero Entry Fan |
Date of each measurement of concentration (MM/DD/YYYY) [§98.326(g)] | 2020-05-21 |
Dates when continuous monitoring equipment for the concentration is not properly functioning, if applicable (MM/DD/YYYY) [§98.326(n)] - Start date | |
Stop date | |
T - Temperature used in Eq. FF-1 (°R) [§98.326(o)] | 522.37 |
Length of time that substitute data are used for the temperature used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(o)] | 0 |
P - Absolute Pressure used in Eq. FF-1 (atm) [§98.326(o)] | 0.78 |
Length of time that substitute data are used for the pressure used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(o)] | 0 |
Were the Quarterly Ventilation Flow Rate and Quarterly CH4 Concentration measured on the same basis? [§98.326(f)-(g)] | Flow rate was measured on a wet basis and CH4 concentration was measured on a dry basis |
Was a flow meter used? [§98.326(f)-(g)] | A flow meter was not used |
fH2O - Moisture content used in Eq. FF-1 (cubic feet water per cubic feet biogas) [§98.326(o)] | 0.0172 |
Length of time that substitute data are used for the moisture content used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(o)] | 0 |
Moisture correction factor used in Eq. FF-1 [§98.326(o)] | 0.9828 |
Length of time that substitute data are used for the moisture correction factor used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(o)] | 0 |
CH4V - Quarterly CH4 liberated from ventilation monitoring point (MT CH4) [§98.326(a)] --- Output of Eq. FF-1 | 8.13 |
File name of MSHA report used to report quarterly CH4 concentration and volumetric flow rate [§98.326(a)] | |
Ventilation Monitoring Point that corresponds to centralized monitoring point or individual shaft from previous tab [§98.326(l)] | Twentymile Five Main North Fan |
Quarter | 2 |
Dates where active ventilation of mining operations is taking place (MM/DD/YYYY) [§98.326(l)] - Start date | 2020-05-01 |
Stop date | 2020-05-31 |
Method used for flow rate [§98.326(f), (r), (s)] | Monitored using 98.324(b)(1) |
V - Quarterly volumetric flow rate used in Eq. FF-1 (acfm or scfm per selection in column A7) [§98.326(f)] | 972400 |
Specify units for parameter V, quarterly volumetric flow rate [§98.326(f)] | acfm |
Length of time that substitute data are used for the quarterly volumetric flow rate used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(f)] | 0 |
Location of each measurement of flow rate used in Eq. FF-1 [§98.326(f)] | Twentymile Five Main North Fan |
Date of each measurement of flow rate used in Eq. FF-1 (MM/DD/YYYY) [§98.326(f)] | 2020-05-21 |
Dates when continuous monitoring equipment for the flow rate is not properly functioning, if applicable (MM/DD/YYYY) [§98.326(n)] - Start date | |
Stop date | |
Method used for concentration [§98.326(g), (r), (s)] | Monitored using 98.324(b)(1) |
C - Quarterly CH4 concentration used in Eq. FF-1 (volume %) [§98.326(g)] | 0.007 |
Was Eq. FF-9 required to calculate CH4 concentration? [§98.326(o)] | No |
If yes, provide the gaseous organic concentration correction factor, used in Eq. FF-9 [§98.326(o)] | |
Length of time that substitute data are used for the quarterly CH4 concentration (hours) [§98.3(c)(8), §98.326(g)] | 0 |
Location of each measurement of concentration [§98.326(g)] | Twentymile Five Main North Fan |
Date of each measurement of concentration (MM/DD/YYYY) [§98.326(g)] | 2020-05-21 |
Dates when continuous monitoring equipment for the concentration is not properly functioning, if applicable (MM/DD/YYYY) [§98.326(n)] - Start date | |
Stop date | |
T - Temperature used in Eq. FF-1 (°R) [§98.326(o)] | 525.37 |
Length of time that substitute data are used for the temperature used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(o)] | 0 |
P - Absolute Pressure used in Eq. FF-1 (atm) [§98.326(o)] | 0.78 |
Length of time that substitute data are used for the pressure used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(o)] | 0 |
Were the Quarterly Ventilation Flow Rate and Quarterly CH4 Concentration measured on the same basis? [§98.326(f)-(g)] | Flow rate was measured on a wet basis and CH4 concentration was measured on a dry basis |
Was a flow meter used? [§98.326(f)-(g)] | A flow meter was not used |
fH2O - Moisture content used in Eq. FF-1 (cubic feet water per cubic feet biogas) [§98.326(o)] | 0.0092 |
Length of time that substitute data are used for the moisture content used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(o)] | 0 |
Moisture correction factor used in Eq. FF-1 [§98.326(o)] | 0.9908 |
Length of time that substitute data are used for the moisture correction factor used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(o)] | 0 |
CH4V - Quarterly CH4 liberated from ventilation monitoring point (MT CH4) [§98.326(a)] --- Output of Eq. FF-1 | 44.81 |
File name of MSHA report used to report quarterly CH4 concentration and volumetric flow rate [§98.326(a)] | |
Ventilation Monitoring Point that corresponds to centralized monitoring point or individual shaft from previous tab [§98.326(l)] | 9E Exhauster |
Quarter | 2 |
Dates where active ventilation of mining operations is taking place (MM/DD/YYYY) [§98.326(l)] - Start date | 2020-05-28 |
Stop date | 2020-05-31 |
Method used for flow rate [§98.326(f), (r), (s)] | Monitored using 98.324(b)(1) |
V - Quarterly volumetric flow rate used in Eq. FF-1 (acfm or scfm per selection in column A7) [§98.326(f)] | 3500 |
Specify units for parameter V, quarterly volumetric flow rate [§98.326(f)] | acfm |
Length of time that substitute data are used for the quarterly volumetric flow rate used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(f)] | 96 |
Location of each measurement of flow rate used in Eq. FF-1 [§98.326(f)] | 9E Exhauster |
Date of each measurement of flow rate used in Eq. FF-1 (MM/DD/YYYY) [§98.326(f)] | 2020-06-29 |
Dates when continuous monitoring equipment for the flow rate is not properly functioning, if applicable (MM/DD/YYYY) [§98.326(n)] - Start date | |
Stop date | |
Method used for concentration [§98.326(g), (r), (s)] | Monitored using 98.324(b)(1) |
C - Quarterly CH4 concentration used in Eq. FF-1 (volume %) [§98.326(g)] | 0.0017 |
Was Eq. FF-9 required to calculate CH4 concentration? [§98.326(o)] | No |
If yes, provide the gaseous organic concentration correction factor, used in Eq. FF-9 [§98.326(o)] | |
Length of time that substitute data are used for the quarterly CH4 concentration (hours) [§98.3(c)(8), §98.326(g)] | 96 |
Location of each measurement of concentration [§98.326(g)] | 9E Exhauster |
Date of each measurement of concentration (MM/DD/YYYY) [§98.326(g)] | 2020-06-29 |
Dates when continuous monitoring equipment for the concentration is not properly functioning, if applicable (MM/DD/YYYY) [§98.326(n)] - Start date | |
Stop date | |
T - Temperature used in Eq. FF-1 (°R) [§98.326(o)] | 537.07 |
Length of time that substitute data are used for the temperature used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(o)] | 96 |
P - Absolute Pressure used in Eq. FF-1 (atm) [§98.326(o)] | 0.78 |
Length of time that substitute data are used for the pressure used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(o)] | 96 |
Were the Quarterly Ventilation Flow Rate and Quarterly CH4 Concentration measured on the same basis? [§98.326(f)-(g)] | Flow rate was measured on a wet basis and CH4 concentration was measured on a dry basis |
Was a flow meter used? [§98.326(f)-(g)] | A flow meter was not used |
fH2O - Moisture content used in Eq. FF-1 (cubic feet water per cubic feet biogas) [§98.326(o)] | 0.0082 |
Length of time that substitute data are used for the moisture content used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(o)] | 96 |
Moisture correction factor used in Eq. FF-1 [§98.326(o)] | 0.9918 |
Length of time that substitute data are used for the moisture correction factor used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(o)] | 96 |
CH4V - Quarterly CH4 liberated from ventilation monitoring point (MT CH4) [§98.326(a)] --- Output of Eq. FF-1 | 0 |
File name of MSHA report used to report quarterly CH4 concentration and volumetric flow rate [§98.326(a)] | |
Ventilation Monitoring Point that corresponds to centralized monitoring point or individual shaft from previous tab [§98.326(l)] | Twentymile Zero Entry Fan |
Quarter | 2 |
Dates where active ventilation of mining operations is taking place (MM/DD/YYYY) [§98.326(l)] - Start date | 2020-06-01 |
Stop date | 2020-06-30 |
Method used for flow rate [§98.326(f), (r), (s)] | Monitored using 98.324(b)(1) |
V - Quarterly volumetric flow rate used in Eq. FF-1 (acfm or scfm per selection in column A7) [§98.326(f)] | 261300 |
Specify units for parameter V, quarterly volumetric flow rate [§98.326(f)] | acfm |
Length of time that substitute data are used for the quarterly volumetric flow rate used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(f)] | 0 |
Location of each measurement of flow rate used in Eq. FF-1 [§98.326(f)] | Twentymile Zero Entry Fan |
Date of each measurement of flow rate used in Eq. FF-1 (MM/DD/YYYY) [§98.326(f)] | 2020-06-29 |
Dates when continuous monitoring equipment for the flow rate is not properly functioning, if applicable (MM/DD/YYYY) [§98.326(n)] - Start date | |
Stop date | |
Method used for concentration [§98.326(g), (r), (s)] | Monitored using 98.324(b)(1) |
C - Quarterly CH4 concentration used in Eq. FF-1 (volume %) [§98.326(g)] | 0.0017 |
Was Eq. FF-9 required to calculate CH4 concentration? [§98.326(o)] | No |
If yes, provide the gaseous organic concentration correction factor, used in Eq. FF-9 [§98.326(o)] | |
Length of time that substitute data are used for the quarterly CH4 concentration (hours) [§98.3(c)(8), §98.326(g)] | 0 |
Location of each measurement of concentration [§98.326(g)] | Twentymile Zero Entry Fan |
Date of each measurement of concentration (MM/DD/YYYY) [§98.326(g)] | 2020-06-29 |
Dates when continuous monitoring equipment for the concentration is not properly functioning, if applicable (MM/DD/YYYY) [§98.326(n)] - Start date | |
Stop date | |
T - Temperature used in Eq. FF-1 (°R) [§98.326(o)] | 520.97 |
Length of time that substitute data are used for the temperature used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(o)] | 0 |
P - Absolute Pressure used in Eq. FF-1 (atm) [§98.326(o)] | 0.78 |
Length of time that substitute data are used for the pressure used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(o)] | 0 |
Were the Quarterly Ventilation Flow Rate and Quarterly CH4 Concentration measured on the same basis? [§98.326(f)-(g)] | Flow rate was measured on a wet basis and CH4 concentration was measured on a dry basis |
Was a flow meter used? [§98.326(f)-(g)] | A flow meter was not used |
fH2O - Moisture content used in Eq. FF-1 (cubic feet water per cubic feet biogas) [§98.326(o)] | 0.011 |
Length of time that substitute data are used for the moisture content used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(o)] | 0 |
Moisture correction factor used in Eq. FF-1 [§98.326(o)] | 0.989 |
Length of time that substitute data are used for the moisture correction factor used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(o)] | 0 |
CH4V - Quarterly CH4 liberated from ventilation monitoring point (MT CH4) [§98.326(a)] --- Output of Eq. FF-1 | 2.82 |
File name of MSHA report used to report quarterly CH4 concentration and volumetric flow rate [§98.326(a)] | |
Ventilation Monitoring Point that corresponds to centralized monitoring point or individual shaft from previous tab [§98.326(l)] | Twentymile Five Main North Fan |
Quarter | 2 |
Dates where active ventilation of mining operations is taking place (MM/DD/YYYY) [§98.326(l)] - Start date | 2020-06-01 |
Stop date | 2020-06-30 |
Method used for flow rate [§98.326(f), (r), (s)] | Monitored using 98.324(b)(1) |
V - Quarterly volumetric flow rate used in Eq. FF-1 (acfm or scfm per selection in column A7) [§98.326(f)] | 996900 |
Specify units for parameter V, quarterly volumetric flow rate [§98.326(f)] | acfm |
Length of time that substitute data are used for the quarterly volumetric flow rate used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(f)] | 0 |
Location of each measurement of flow rate used in Eq. FF-1 [§98.326(f)] | Twentymile Five Main North Fan |
Date of each measurement of flow rate used in Eq. FF-1 (MM/DD/YYYY) [§98.326(f)] | 2020-06-29 |
Dates when continuous monitoring equipment for the flow rate is not properly functioning, if applicable (MM/DD/YYYY) [§98.326(n)] - Start date | |
Stop date | |
Method used for concentration [§98.326(g), (r), (s)] | Monitored using 98.324(b)(1) |
C - Quarterly CH4 concentration used in Eq. FF-1 (volume %) [§98.326(g)] | 0.0015 |
Was Eq. FF-9 required to calculate CH4 concentration? [§98.326(o)] | No |
If yes, provide the gaseous organic concentration correction factor, used in Eq. FF-9 [§98.326(o)] | |
Length of time that substitute data are used for the quarterly CH4 concentration (hours) [§98.3(c)(8), §98.326(g)] | 0 |
Location of each measurement of concentration [§98.326(g)] | Twentymile Five Main North Fan |
Date of each measurement of concentration (MM/DD/YYYY) [§98.326(g)] | 2020-06-29 |
Dates when continuous monitoring equipment for the concentration is not properly functioning, if applicable (MM/DD/YYYY) [§98.326(n)] - Start date | |
Stop date | |
T - Temperature used in Eq. FF-1 (°R) [§98.326(o)] | 529.17 |
Length of time that substitute data are used for the temperature used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(o)] | 0 |
P - Absolute Pressure used in Eq. FF-1 (atm) [§98.326(o)] | 0.78 |
Length of time that substitute data are used for the pressure used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(o)] | 0 |
Were the Quarterly Ventilation Flow Rate and Quarterly CH4 Concentration measured on the same basis? [§98.326(f)-(g)] | Flow rate was measured on a wet basis and CH4 concentration was measured on a dry basis |
Was a flow meter used? [§98.326(f)-(g)] | A flow meter was not used |
fH2O - Moisture content used in Eq. FF-1 (cubic feet water per cubic feet biogas) [§98.326(o)] | 0.0141 |
Length of time that substitute data are used for the moisture content used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(o)] | 0 |
Moisture correction factor used in Eq. FF-1 [§98.326(o)] | 0.9859 |
Length of time that substitute data are used for the moisture correction factor used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(o)] | 0 |
CH4V - Quarterly CH4 liberated from ventilation monitoring point (MT CH4) [§98.326(a)] --- Output of Eq. FF-1 | 9.35 |
File name of MSHA report used to report quarterly CH4 concentration and volumetric flow rate [§98.326(a)] | |
Ventilation Monitoring Point that corresponds to centralized monitoring point or individual shaft from previous tab [§98.326(l)] | 9E Exhauster |
Quarter | 2 |
Dates where active ventilation of mining operations is taking place (MM/DD/YYYY) [§98.326(l)] - Start date | 2020-06-01 |
Stop date | 2020-06-30 |
Method used for flow rate [§98.326(f), (r), (s)] | Monitored using 98.324(b)(1) |
V - Quarterly volumetric flow rate used in Eq. FF-1 (acfm or scfm per selection in column A7) [§98.326(f)] | 3500 |
Specify units for parameter V, quarterly volumetric flow rate [§98.326(f)] | acfm |
Length of time that substitute data are used for the quarterly volumetric flow rate used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(f)] | 0 |
Location of each measurement of flow rate used in Eq. FF-1 [§98.326(f)] | 9E Exhauster |
Date of each measurement of flow rate used in Eq. FF-1 (MM/DD/YYYY) [§98.326(f)] | 2020-06-29 |
Dates when continuous monitoring equipment for the flow rate is not properly functioning, if applicable (MM/DD/YYYY) [§98.326(n)] - Start date | |
Stop date | |
Method used for concentration [§98.326(g), (r), (s)] | Monitored using 98.324(b)(1) |
C - Quarterly CH4 concentration used in Eq. FF-1 (volume %) [§98.326(g)] | 0.0017 |
Was Eq. FF-9 required to calculate CH4 concentration? [§98.326(o)] | No |
If yes, provide the gaseous organic concentration correction factor, used in Eq. FF-9 [§98.326(o)] | |
Length of time that substitute data are used for the quarterly CH4 concentration (hours) [§98.3(c)(8), §98.326(g)] | 0 |
Location of each measurement of concentration [§98.326(g)] | 9E Exhauster |
Date of each measurement of concentration (MM/DD/YYYY) [§98.326(g)] | 2020-06-29 |
Dates when continuous monitoring equipment for the concentration is not properly functioning, if applicable (MM/DD/YYYY) [§98.326(n)] - Start date | |
Stop date | |
T - Temperature used in Eq. FF-1 (°R) [§98.326(o)] | 537.07 |
Length of time that substitute data are used for the temperature used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(o)] | 0 |
P - Absolute Pressure used in Eq. FF-1 (atm) [§98.326(o)] | 0.78 |
Length of time that substitute data are used for the pressure used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(o)] | 0 |
Were the Quarterly Ventilation Flow Rate and Quarterly CH4 Concentration measured on the same basis? [§98.326(f)-(g)] | Flow rate was measured on a wet basis and CH4 concentration was measured on a dry basis |
Was a flow meter used? [§98.326(f)-(g)] | A flow meter was not used |
fH2O - Moisture content used in Eq. FF-1 (cubic feet water per cubic feet biogas) [§98.326(o)] | 0.0082 |
Length of time that substitute data are used for the moisture content used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(o)] | 0 |
Moisture correction factor used in Eq. FF-1 [§98.326(o)] | 0.9918 |
Length of time that substitute data are used for the moisture correction factor used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(o)] | 0 |
CH4V - Quarterly CH4 liberated from ventilation monitoring point (MT CH4) [§98.326(a)] --- Output of Eq. FF-1 | 0.04 |
File name of MSHA report used to report quarterly CH4 concentration and volumetric flow rate [§98.326(a)] | |
Ventilation Monitoring Point that corresponds to centralized monitoring point or individual shaft from previous tab [§98.326(l)] | Twentymile Zero Entry Fan |
Quarter | 3 |
Dates where active ventilation of mining operations is taking place (MM/DD/YYYY) [§98.326(l)] - Start date | 2020-07-01 |
Stop date | 2020-07-31 |
Method used for flow rate [§98.326(f), (r), (s)] | Monitored using 98.324(b)(1) |
V - Quarterly volumetric flow rate used in Eq. FF-1 (acfm or scfm per selection in column A7) [§98.326(f)] | 260300 |
Specify units for parameter V, quarterly volumetric flow rate [§98.326(f)] | acfm |
Length of time that substitute data are used for the quarterly volumetric flow rate used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(f)] | 0 |
Location of each measurement of flow rate used in Eq. FF-1 [§98.326(f)] | Twentymile Zero Entry Fan |
Date of each measurement of flow rate used in Eq. FF-1 (MM/DD/YYYY) [§98.326(f)] | 2020-07-30 |
Dates when continuous monitoring equipment for the flow rate is not properly functioning, if applicable (MM/DD/YYYY) [§98.326(n)] - Start date | |
Stop date | |
Method used for concentration [§98.326(g), (r), (s)] | Monitored using 98.324(b)(1) |
C - Quarterly CH4 concentration used in Eq. FF-1 (volume %) [§98.326(g)] | 0.0055 |
Was Eq. FF-9 required to calculate CH4 concentration? [§98.326(o)] | No |
If yes, provide the gaseous organic concentration correction factor, used in Eq. FF-9 [§98.326(o)] | |
Length of time that substitute data are used for the quarterly CH4 concentration (hours) [§98.3(c)(8), §98.326(g)] | 0 |
Location of each measurement of concentration [§98.326(g)] | Twentymile Zero Entry Fan |
Date of each measurement of concentration (MM/DD/YYYY) [§98.326(g)] | 2020-07-30 |
Dates when continuous monitoring equipment for the concentration is not properly functioning, if applicable (MM/DD/YYYY) [§98.326(n)] - Start date | |
Stop date | |
T - Temperature used in Eq. FF-1 (°R) [§98.326(o)] | 527.77 |
Length of time that substitute data are used for the temperature used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(o)] | 0 |
P - Absolute Pressure used in Eq. FF-1 (atm) [§98.326(o)] | 0.79 |
Length of time that substitute data are used for the pressure used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(o)] | 0 |
Were the Quarterly Ventilation Flow Rate and Quarterly CH4 Concentration measured on the same basis? [§98.326(f)-(g)] | Flow rate was measured on a wet basis and CH4 concentration was measured on a dry basis |
Was a flow meter used? [§98.326(f)-(g)] | A flow meter was not used |
fH2O - Moisture content used in Eq. FF-1 (cubic feet water per cubic feet biogas) [§98.326(o)] | 0.0137 |
Length of time that substitute data are used for the moisture content used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(o)] | 0 |
Moisture correction factor used in Eq. FF-1 [§98.326(o)] | 0.9863 |
Length of time that substitute data are used for the moisture correction factor used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(o)] | 0 |
CH4V - Quarterly CH4 liberated from ventilation monitoring point (MT CH4) [§98.326(a)] --- Output of Eq. FF-1 | 9.4 |
File name of MSHA report used to report quarterly CH4 concentration and volumetric flow rate [§98.326(a)] | |
Ventilation Monitoring Point that corresponds to centralized monitoring point or individual shaft from previous tab [§98.326(l)] | Twentymile Five Main North Fan |
Quarter | 3 |
Dates where active ventilation of mining operations is taking place (MM/DD/YYYY) [§98.326(l)] - Start date | 2020-07-01 |
Stop date | 2020-07-31 |
Method used for flow rate [§98.326(f), (r), (s)] | Monitored using 98.324(b)(1) |
V - Quarterly volumetric flow rate used in Eq. FF-1 (acfm or scfm per selection in column A7) [§98.326(f)] | 930000 |
Specify units for parameter V, quarterly volumetric flow rate [§98.326(f)] | acfm |
Length of time that substitute data are used for the quarterly volumetric flow rate used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(f)] | 0 |
Location of each measurement of flow rate used in Eq. FF-1 [§98.326(f)] | Twentymile Five Main North Fan |
Date of each measurement of flow rate used in Eq. FF-1 (MM/DD/YYYY) [§98.326(f)] | 2020-07-30 |
Dates when continuous monitoring equipment for the flow rate is not properly functioning, if applicable (MM/DD/YYYY) [§98.326(n)] - Start date | |
Stop date | |
Method used for concentration [§98.326(g), (r), (s)] | Monitored using 98.324(b)(1) |
C - Quarterly CH4 concentration used in Eq. FF-1 (volume %) [§98.326(g)] | 0.05 |
Was Eq. FF-9 required to calculate CH4 concentration? [§98.326(o)] | No |
If yes, provide the gaseous organic concentration correction factor, used in Eq. FF-9 [§98.326(o)] | |
Length of time that substitute data are used for the quarterly CH4 concentration (hours) [§98.3(c)(8), §98.326(g)] | 0 |
Location of each measurement of concentration [§98.326(g)] | Twentymile Five Main North Fan |
Date of each measurement of concentration (MM/DD/YYYY) [§98.326(g)] | 2020-07-30 |
Dates when continuous monitoring equipment for the concentration is not properly functioning, if applicable (MM/DD/YYYY) [§98.326(n)] - Start date | |
Stop date | |
T - Temperature used in Eq. FF-1 (°R) [§98.326(o)] | 532.17 |
Length of time that substitute data are used for the temperature used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(o)] | 0 |
P - Absolute Pressure used in Eq. FF-1 (atm) [§98.326(o)] | 0.79 |
Length of time that substitute data are used for the pressure used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(o)] | 0 |
Were the Quarterly Ventilation Flow Rate and Quarterly CH4 Concentration measured on the same basis? [§98.326(f)-(g)] | Flow rate was measured on a wet basis and CH4 concentration was measured on a dry basis |
Was a flow meter used? [§98.326(f)-(g)] | A flow meter was not used |
fH2O - Moisture content used in Eq. FF-1 (cubic feet water per cubic feet biogas) [§98.326(o)] | 0.0147 |
Length of time that substitute data are used for the moisture content used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(o)] | 0 |
Moisture correction factor used in Eq. FF-1 [§98.326(o)] | 0.9853 |
Length of time that substitute data are used for the moisture correction factor used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(o)] | 0 |
CH4V - Quarterly CH4 liberated from ventilation monitoring point (MT CH4) [§98.326(a)] --- Output of Eq. FF-1 | 304.39 |
File name of MSHA report used to report quarterly CH4 concentration and volumetric flow rate [§98.326(a)] | |
Ventilation Monitoring Point that corresponds to centralized monitoring point or individual shaft from previous tab [§98.326(l)] | 9E Exhauster |
Quarter | 3 |
Dates where active ventilation of mining operations is taking place (MM/DD/YYYY) [§98.326(l)] - Start date | 2020-07-01 |
Stop date | 2020-07-31 |
Method used for flow rate [§98.326(f), (r), (s)] | Monitored using 98.324(b)(1) |
V - Quarterly volumetric flow rate used in Eq. FF-1 (acfm or scfm per selection in column A7) [§98.326(f)] | 6800 |
Specify units for parameter V, quarterly volumetric flow rate [§98.326(f)] | acfm |
Length of time that substitute data are used for the quarterly volumetric flow rate used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(f)] | 0 |
Location of each measurement of flow rate used in Eq. FF-1 [§98.326(f)] | 9E Exhauster |
Date of each measurement of flow rate used in Eq. FF-1 (MM/DD/YYYY) [§98.326(f)] | 2020-07-30 |
Dates when continuous monitoring equipment for the flow rate is not properly functioning, if applicable (MM/DD/YYYY) [§98.326(n)] - Start date | |
Stop date | |
Method used for concentration [§98.326(g), (r), (s)] | Monitored using 98.324(b)(1) |
C - Quarterly CH4 concentration used in Eq. FF-1 (volume %) [§98.326(g)] | 0.0053 |
Was Eq. FF-9 required to calculate CH4 concentration? [§98.326(o)] | No |
If yes, provide the gaseous organic concentration correction factor, used in Eq. FF-9 [§98.326(o)] | |
Length of time that substitute data are used for the quarterly CH4 concentration (hours) [§98.3(c)(8), §98.326(g)] | 0 |
Location of each measurement of concentration [§98.326(g)] | 9E Exhauster |
Date of each measurement of concentration (MM/DD/YYYY) [§98.326(g)] | 2020-07-30 |
Dates when continuous monitoring equipment for the concentration is not properly functioning, if applicable (MM/DD/YYYY) [§98.326(n)] - Start date | |
Stop date | |
T - Temperature used in Eq. FF-1 (°R) [§98.326(o)] | 538.97 |
Length of time that substitute data are used for the temperature used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(o)] | 0 |
P - Absolute Pressure used in Eq. FF-1 (atm) [§98.326(o)] | 0.79 |
Length of time that substitute data are used for the pressure used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(o)] | 0 |
Were the Quarterly Ventilation Flow Rate and Quarterly CH4 Concentration measured on the same basis? [§98.326(f)-(g)] | Flow rate was measured on a wet basis and CH4 concentration was measured on a dry basis |
Was a flow meter used? [§98.326(f)-(g)] | A flow meter was not used |
fH2O - Moisture content used in Eq. FF-1 (cubic feet water per cubic feet biogas) [§98.326(o)] | 0.0074 |
Length of time that substitute data are used for the moisture content used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(o)] | 0 |
Moisture correction factor used in Eq. FF-1 [§98.326(o)] | 0.9926 |
Length of time that substitute data are used for the moisture correction factor used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(o)] | 0 |
CH4V - Quarterly CH4 liberated from ventilation monitoring point (MT CH4) [§98.326(a)] --- Output of Eq. FF-1 | 0.23 |
File name of MSHA report used to report quarterly CH4 concentration and volumetric flow rate [§98.326(a)] | |
Ventilation Monitoring Point that corresponds to centralized monitoring point or individual shaft from previous tab [§98.326(l)] | Twentymile Zero Entry Fan |
Quarter | 3 |
Dates where active ventilation of mining operations is taking place (MM/DD/YYYY) [§98.326(l)] - Start date | 2020-08-01 |
Stop date | 2020-08-22 |
Method used for flow rate [§98.326(f), (r), (s)] | Monitored using 98.324(b)(1) |
V - Quarterly volumetric flow rate used in Eq. FF-1 (acfm or scfm per selection in column A7) [§98.326(f)] | 260300 |
Specify units for parameter V, quarterly volumetric flow rate [§98.326(f)] | acfm |
Length of time that substitute data are used for the quarterly volumetric flow rate used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(f)] | 0 |
Location of each measurement of flow rate used in Eq. FF-1 [§98.326(f)] | Twentymile Zero Entry Fan |
Date of each measurement of flow rate used in Eq. FF-1 (MM/DD/YYYY) [§98.326(f)] | 2020-08-22 |
Dates when continuous monitoring equipment for the flow rate is not properly functioning, if applicable (MM/DD/YYYY) [§98.326(n)] - Start date | |
Stop date | |
Method used for concentration [§98.326(g), (r), (s)] | Monitored using 98.324(b)(1) |
C - Quarterly CH4 concentration used in Eq. FF-1 (volume %) [§98.326(g)] | 0.0055 |
Was Eq. FF-9 required to calculate CH4 concentration? [§98.326(o)] | No |
If yes, provide the gaseous organic concentration correction factor, used in Eq. FF-9 [§98.326(o)] | |
Length of time that substitute data are used for the quarterly CH4 concentration (hours) [§98.3(c)(8), §98.326(g)] | 0 |
Location of each measurement of concentration [§98.326(g)] | Twentymile Zero Entry Fan |
Date of each measurement of concentration (MM/DD/YYYY) [§98.326(g)] | 2020-08-22 |
Dates when continuous monitoring equipment for the concentration is not properly functioning, if applicable (MM/DD/YYYY) [§98.326(n)] - Start date | |
Stop date | |
T - Temperature used in Eq. FF-1 (°R) [§98.326(o)] | 527.77 |
Length of time that substitute data are used for the temperature used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(o)] | 0 |
P - Absolute Pressure used in Eq. FF-1 (atm) [§98.326(o)] | 0.79 |
Length of time that substitute data are used for the pressure used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(o)] | 0 |
Were the Quarterly Ventilation Flow Rate and Quarterly CH4 Concentration measured on the same basis? [§98.326(f)-(g)] | Flow rate was measured on a wet basis and CH4 concentration was measured on a dry basis |
Was a flow meter used? [§98.326(f)-(g)] | A flow meter was not used |
fH2O - Moisture content used in Eq. FF-1 (cubic feet water per cubic feet biogas) [§98.326(o)] | 0.0137 |
Length of time that substitute data are used for the moisture content used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(o)] | 0 |
Moisture correction factor used in Eq. FF-1 [§98.326(o)] | 0.9863 |
Length of time that substitute data are used for the moisture correction factor used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(o)] | 0 |
CH4V - Quarterly CH4 liberated from ventilation monitoring point (MT CH4) [§98.326(a)] --- Output of Eq. FF-1 | 6.67 |
File name of MSHA report used to report quarterly CH4 concentration and volumetric flow rate [§98.326(a)] | |
Ventilation Monitoring Point that corresponds to centralized monitoring point or individual shaft from previous tab [§98.326(l)] | Twentymile Five Main North Fan |
Quarter | 3 |
Dates where active ventilation of mining operations is taking place (MM/DD/YYYY) [§98.326(l)] - Start date | 2020-08-01 |
Stop date | 2020-08-31 |
Method used for flow rate [§98.326(f), (r), (s)] | Monitored using 98.324(b)(1) |
V - Quarterly volumetric flow rate used in Eq. FF-1 (acfm or scfm per selection in column A7) [§98.326(f)] | 903800 |
Specify units for parameter V, quarterly volumetric flow rate [§98.326(f)] | acfm |
Length of time that substitute data are used for the quarterly volumetric flow rate used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(f)] | 0 |
Location of each measurement of flow rate used in Eq. FF-1 [§98.326(f)] | Twentymile Five Main North Fan |
Date of each measurement of flow rate used in Eq. FF-1 (MM/DD/YYYY) [§98.326(f)] | 2020-08-31 |
Dates when continuous monitoring equipment for the flow rate is not properly functioning, if applicable (MM/DD/YYYY) [§98.326(n)] - Start date | |
Stop date | |
Method used for concentration [§98.326(g), (r), (s)] | Monitored using 98.324(b)(1) |
C - Quarterly CH4 concentration used in Eq. FF-1 (volume %) [§98.326(g)] | 0.0514 |
Was Eq. FF-9 required to calculate CH4 concentration? [§98.326(o)] | No |
If yes, provide the gaseous organic concentration correction factor, used in Eq. FF-9 [§98.326(o)] | |
Length of time that substitute data are used for the quarterly CH4 concentration (hours) [§98.3(c)(8), §98.326(g)] | 0 |
Location of each measurement of concentration [§98.326(g)] | Twentymile Five Main North Fan |
Date of each measurement of concentration (MM/DD/YYYY) [§98.326(g)] | 2020-08-31 |
Dates when continuous monitoring equipment for the concentration is not properly functioning, if applicable (MM/DD/YYYY) [§98.326(n)] - Start date | |
Stop date | |
T - Temperature used in Eq. FF-1 (°R) [§98.326(o)] | 530.47 |
Length of time that substitute data are used for the temperature used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(o)] | 0 |
P - Absolute Pressure used in Eq. FF-1 (atm) [§98.326(o)] | 0.78 |
Length of time that substitute data are used for the pressure used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(o)] | 0 |
Were the Quarterly Ventilation Flow Rate and Quarterly CH4 Concentration measured on the same basis? [§98.326(f)-(g)] | Flow rate was measured on a wet basis and CH4 concentration was measured on a dry basis |
Was a flow meter used? [§98.326(f)-(g)] | A flow meter was not used |
fH2O - Moisture content used in Eq. FF-1 (cubic feet water per cubic feet biogas) [§98.326(o)] | 0.0153 |
Length of time that substitute data are used for the moisture content used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(o)] | 0 |
Moisture correction factor used in Eq. FF-1 [§98.326(o)] | 0.9847 |
Length of time that substitute data are used for the moisture correction factor used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(o)] | 0 |
CH4V - Quarterly CH4 liberated from ventilation monitoring point (MT CH4) [§98.326(a)] --- Output of Eq. FF-1 | 299.88 |
File name of MSHA report used to report quarterly CH4 concentration and volumetric flow rate [§98.326(a)] | |
Ventilation Monitoring Point that corresponds to centralized monitoring point or individual shaft from previous tab [§98.326(l)] | 9E Exhauster |
Quarter | 3 |
Dates where active ventilation of mining operations is taking place (MM/DD/YYYY) [§98.326(l)] - Start date | 2020-08-01 |
Stop date | 2020-08-31 |
Method used for flow rate [§98.326(f), (r), (s)] | Monitored using 98.324(b)(1) |
V - Quarterly volumetric flow rate used in Eq. FF-1 (acfm or scfm per selection in column A7) [§98.326(f)] | 6500 |
Specify units for parameter V, quarterly volumetric flow rate [§98.326(f)] | acfm |
Length of time that substitute data are used for the quarterly volumetric flow rate used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(f)] | 0 |
Location of each measurement of flow rate used in Eq. FF-1 [§98.326(f)] | 9E Exhauster |
Date of each measurement of flow rate used in Eq. FF-1 (MM/DD/YYYY) [§98.326(f)] | 2020-08-31 |
Dates when continuous monitoring equipment for the flow rate is not properly functioning, if applicable (MM/DD/YYYY) [§98.326(n)] - Start date | |
Stop date | |
Method used for concentration [§98.326(g), (r), (s)] | Monitored using 98.324(b)(1) |
C - Quarterly CH4 concentration used in Eq. FF-1 (volume %) [§98.326(g)] | 0.0175 |
Was Eq. FF-9 required to calculate CH4 concentration? [§98.326(o)] | No |
If yes, provide the gaseous organic concentration correction factor, used in Eq. FF-9 [§98.326(o)] | |
Length of time that substitute data are used for the quarterly CH4 concentration (hours) [§98.3(c)(8), §98.326(g)] | 0 |
Location of each measurement of concentration [§98.326(g)] | 9E Exhauster |
Date of each measurement of concentration (MM/DD/YYYY) [§98.326(g)] | 2020-08-31 |
Dates when continuous monitoring equipment for the concentration is not properly functioning, if applicable (MM/DD/YYYY) [§98.326(n)] - Start date | |
Stop date | |
T - Temperature used in Eq. FF-1 (°R) [§98.326(o)] | 538.27 |
Length of time that substitute data are used for the temperature used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(o)] | 0 |
P - Absolute Pressure used in Eq. FF-1 (atm) [§98.326(o)] | 0.78 |
Length of time that substitute data are used for the pressure used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(o)] | 0 |
Were the Quarterly Ventilation Flow Rate and Quarterly CH4 Concentration measured on the same basis? [§98.326(f)-(g)] | Flow rate was measured on a wet basis and CH4 concentration was measured on a dry basis |
Was a flow meter used? [§98.326(f)-(g)] | A flow meter was not used |
fH2O - Moisture content used in Eq. FF-1 (cubic feet water per cubic feet biogas) [§98.326(o)] | 0.0045 |
Length of time that substitute data are used for the moisture content used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(o)] | 0 |
Moisture correction factor used in Eq. FF-1 [§98.326(o)] | 0.9955 |
Length of time that substitute data are used for the moisture correction factor used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(o)] | 0 |
CH4V - Quarterly CH4 liberated from ventilation monitoring point (MT CH4) [§98.326(a)] --- Output of Eq. FF-1 | 0.73 |
File name of MSHA report used to report quarterly CH4 concentration and volumetric flow rate [§98.326(a)] | |
Ventilation Monitoring Point that corresponds to centralized monitoring point or individual shaft from previous tab [§98.326(l)] | Twentymile Five Main North Fan |
Quarter | 3 |
Dates where active ventilation of mining operations is taking place (MM/DD/YYYY) [§98.326(l)] - Start date | 2020-09-01 |
Stop date | 2020-09-30 |
Method used for flow rate [§98.326(f), (r), (s)] | Monitored using 98.324(b)(1) |
V - Quarterly volumetric flow rate used in Eq. FF-1 (acfm or scfm per selection in column A7) [§98.326(f)] | 904500 |
Specify units for parameter V, quarterly volumetric flow rate [§98.326(f)] | acfm |
Length of time that substitute data are used for the quarterly volumetric flow rate used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(f)] | 0 |
Location of each measurement of flow rate used in Eq. FF-1 [§98.326(f)] | Twentymile Five Main North Fan |
Date of each measurement of flow rate used in Eq. FF-1 (MM/DD/YYYY) [§98.326(f)] | 2020-09-28 |
Dates when continuous monitoring equipment for the flow rate is not properly functioning, if applicable (MM/DD/YYYY) [§98.326(n)] - Start date | |
Stop date | |
Method used for concentration [§98.326(g), (r), (s)] | Monitored using 98.324(b)(1) |
C - Quarterly CH4 concentration used in Eq. FF-1 (volume %) [§98.326(g)] | 0.0657 |
Was Eq. FF-9 required to calculate CH4 concentration? [§98.326(o)] | No |
If yes, provide the gaseous organic concentration correction factor, used in Eq. FF-9 [§98.326(o)] | |
Length of time that substitute data are used for the quarterly CH4 concentration (hours) [§98.3(c)(8), §98.326(g)] | 0 |
Location of each measurement of concentration [§98.326(g)] | Twentymile Five Main North Fan |
Date of each measurement of concentration (MM/DD/YYYY) [§98.326(g)] | 2020-09-28 |
Dates when continuous monitoring equipment for the concentration is not properly functioning, if applicable (MM/DD/YYYY) [§98.326(n)] - Start date | |
Stop date | |
T - Temperature used in Eq. FF-1 (°R) [§98.326(o)] | 528.67 |
Length of time that substitute data are used for the temperature used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(o)] | |
P - Absolute Pressure used in Eq. FF-1 (atm) [§98.326(o)] | 0.78 |
Length of time that substitute data are used for the pressure used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(o)] | 0 |
Were the Quarterly Ventilation Flow Rate and Quarterly CH4 Concentration measured on the same basis? [§98.326(f)-(g)] | Flow rate was measured on a wet basis and CH4 concentration was measured on a dry basis |
Was a flow meter used? [§98.326(f)-(g)] | A flow meter was not used |
fH2O - Moisture content used in Eq. FF-1 (cubic feet water per cubic feet biogas) [§98.326(o)] | 0.0147 |
Length of time that substitute data are used for the moisture content used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(o)] | 0 |
Moisture correction factor used in Eq. FF-1 [§98.326(o)] | 0.9853 |
Length of time that substitute data are used for the moisture correction factor used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(o)] | 0 |
CH4V - Quarterly CH4 liberated from ventilation monitoring point (MT CH4) [§98.326(a)] --- Output of Eq. FF-1 | 372.24 |
File name of MSHA report used to report quarterly CH4 concentration and volumetric flow rate [§98.326(a)] | |
Ventilation Monitoring Point that corresponds to centralized monitoring point or individual shaft from previous tab [§98.326(l)] | 9E Exhauster |
Quarter | 3 |
Dates where active ventilation of mining operations is taking place (MM/DD/YYYY) [§98.326(l)] - Start date | 2020-09-01 |
Stop date | 2020-09-30 |
Method used for flow rate [§98.326(f), (r), (s)] | Monitored using 98.324(b)(1) |
V - Quarterly volumetric flow rate used in Eq. FF-1 (acfm or scfm per selection in column A7) [§98.326(f)] | 3400 |
Specify units for parameter V, quarterly volumetric flow rate [§98.326(f)] | acfm |
Length of time that substitute data are used for the quarterly volumetric flow rate used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(f)] | 0 |
Location of each measurement of flow rate used in Eq. FF-1 [§98.326(f)] | 9E Exhauster |
Date of each measurement of flow rate used in Eq. FF-1 (MM/DD/YYYY) [§98.326(f)] | 2020-09-28 |
Dates when continuous monitoring equipment for the flow rate is not properly functioning, if applicable (MM/DD/YYYY) [§98.326(n)] - Start date | |
Stop date | |
Method used for concentration [§98.326(g), (r), (s)] | Monitored using 98.324(b)(1) |
C - Quarterly CH4 concentration used in Eq. FF-1 (volume %) [§98.326(g)] | 0.0077 |
Was Eq. FF-9 required to calculate CH4 concentration? [§98.326(o)] | No |
If yes, provide the gaseous organic concentration correction factor, used in Eq. FF-9 [§98.326(o)] | |
Length of time that substitute data are used for the quarterly CH4 concentration (hours) [§98.3(c)(8), §98.326(g)] | 0 |
Location of each measurement of concentration [§98.326(g)] | 9E Exhauster |
Date of each measurement of concentration (MM/DD/YYYY) [§98.326(g)] | 2020-09-28 |
Dates when continuous monitoring equipment for the concentration is not properly functioning, if applicable (MM/DD/YYYY) [§98.326(n)] - Start date | |
Stop date | |
T - Temperature used in Eq. FF-1 (°R) [§98.326(o)] | 837.87 |
Length of time that substitute data are used for the temperature used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(o)] | |
P - Absolute Pressure used in Eq. FF-1 (atm) [§98.326(o)] | 0.78 |
Length of time that substitute data are used for the pressure used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(o)] | 0 |
Were the Quarterly Ventilation Flow Rate and Quarterly CH4 Concentration measured on the same basis? [§98.326(f)-(g)] | Flow rate was measured on a wet basis and CH4 concentration was measured on a dry basis |
Was a flow meter used? [§98.326(f)-(g)] | A flow meter was not used |
fH2O - Moisture content used in Eq. FF-1 (cubic feet water per cubic feet biogas) [§98.326(o)] | 0.0067 |
Length of time that substitute data are used for the moisture content used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(o)] | 0 |
Moisture correction factor used in Eq. FF-1 [§98.326(o)] | 0.9933 |
Length of time that substitute data are used for the moisture correction factor used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(o)] | 0 |
CH4V - Quarterly CH4 liberated from ventilation monitoring point (MT CH4) [§98.326(a)] --- Output of Eq. FF-1 | 0.16 |
File name of MSHA report used to report quarterly CH4 concentration and volumetric flow rate [§98.326(a)] | |
Ventilation Monitoring Point that corresponds to centralized monitoring point or individual shaft from previous tab [§98.326(l)] | Twentymile Five Main North Fan |
Quarter | 4 |
Dates where active ventilation of mining operations is taking place (MM/DD/YYYY) [§98.326(l)] - Start date | 2020-10-01 |
Stop date | 2020-10-31 |
Method used for flow rate [§98.326(f), (r), (s)] | Monitored using 98.324(b)(1) |
V - Quarterly volumetric flow rate used in Eq. FF-1 (acfm or scfm per selection in column A7) [§98.326(f)] | 826900 |
Specify units for parameter V, quarterly volumetric flow rate [§98.326(f)] | acfm |
Length of time that substitute data are used for the quarterly volumetric flow rate used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(f)] | 0 |
Location of each measurement of flow rate used in Eq. FF-1 [§98.326(f)] | Twentymile Five Main North Fan |
Date of each measurement of flow rate used in Eq. FF-1 (MM/DD/YYYY) [§98.326(f)] | 2020-10-28 |
Dates when continuous monitoring equipment for the flow rate is not properly functioning, if applicable (MM/DD/YYYY) [§98.326(n)] - Start date | |
Stop date | |
Method used for concentration [§98.326(g), (r), (s)] | Monitored using 98.324(b)(1) |
C - Quarterly CH4 concentration used in Eq. FF-1 (volume %) [§98.326(g)] | 0.0465 |
Was Eq. FF-9 required to calculate CH4 concentration? [§98.326(o)] | No |
If yes, provide the gaseous organic concentration correction factor, used in Eq. FF-9 [§98.326(o)] | |
Length of time that substitute data are used for the quarterly CH4 concentration (hours) [§98.3(c)(8), §98.326(g)] | 0 |
Location of each measurement of concentration [§98.326(g)] | Twentymile Five Main North Fan |
Date of each measurement of concentration (MM/DD/YYYY) [§98.326(g)] | 2020-10-28 |
Dates when continuous monitoring equipment for the concentration is not properly functioning, if applicable (MM/DD/YYYY) [§98.326(n)] - Start date | |
Stop date | |
T - Temperature used in Eq. FF-1 (°R) [§98.326(o)] | 524.67 |
Length of time that substitute data are used for the temperature used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(o)] | |
P - Absolute Pressure used in Eq. FF-1 (atm) [§98.326(o)] | 0.79 |
Length of time that substitute data are used for the pressure used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(o)] | 0 |
Were the Quarterly Ventilation Flow Rate and Quarterly CH4 Concentration measured on the same basis? [§98.326(f)-(g)] | Flow rate was measured on a wet basis and CH4 concentration was measured on a dry basis |
Was a flow meter used? [§98.326(f)-(g)] | A flow meter was not used |
fH2O - Moisture content used in Eq. FF-1 (cubic feet water per cubic feet biogas) [§98.326(o)] | 0.0137 |
Length of time that substitute data are used for the moisture content used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(o)] | 0 |
Moisture correction factor used in Eq. FF-1 [§98.326(o)] | 0.9863 |
Length of time that substitute data are used for the moisture correction factor used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(o)] | 0 |
CH4V - Quarterly CH4 liberated from ventilation monitoring point (MT CH4) [§98.326(a)] --- Output of Eq. FF-1 | 253.94 |
File name of MSHA report used to report quarterly CH4 concentration and volumetric flow rate [§98.326(a)] | |
Ventilation Monitoring Point that corresponds to centralized monitoring point or individual shaft from previous tab [§98.326(l)] | 9E Exhauster |
Quarter | 4 |
Dates where active ventilation of mining operations is taking place (MM/DD/YYYY) [§98.326(l)] - Start date | 2020-10-01 |
Stop date | 2020-10-31 |
Method used for flow rate [§98.326(f), (r), (s)] | Monitored using 98.324(b)(1) |
V - Quarterly volumetric flow rate used in Eq. FF-1 (acfm or scfm per selection in column A7) [§98.326(f)] | 4000 |
Specify units for parameter V, quarterly volumetric flow rate [§98.326(f)] | acfm |
Length of time that substitute data are used for the quarterly volumetric flow rate used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(f)] | 0 |
Location of each measurement of flow rate used in Eq. FF-1 [§98.326(f)] | 9E Exhauster |
Date of each measurement of flow rate used in Eq. FF-1 (MM/DD/YYYY) [§98.326(f)] | 2020-10-28 |
Dates when continuous monitoring equipment for the flow rate is not properly functioning, if applicable (MM/DD/YYYY) [§98.326(n)] - Start date | |
Stop date | |
Method used for concentration [§98.326(g), (r), (s)] | Monitored using 98.324(b)(1) |
C - Quarterly CH4 concentration used in Eq. FF-1 (volume %) [§98.326(g)] | 0.0297 |
Was Eq. FF-9 required to calculate CH4 concentration? [§98.326(o)] | No |
If yes, provide the gaseous organic concentration correction factor, used in Eq. FF-9 [§98.326(o)] | |
Length of time that substitute data are used for the quarterly CH4 concentration (hours) [§98.3(c)(8), §98.326(g)] | 0 |
Location of each measurement of concentration [§98.326(g)] | 9E Exhauster |
Date of each measurement of concentration (MM/DD/YYYY) [§98.326(g)] | 2020-10-28 |
Dates when continuous monitoring equipment for the concentration is not properly functioning, if applicable (MM/DD/YYYY) [§98.326(n)] - Start date | |
Stop date | |
T - Temperature used in Eq. FF-1 (°R) [§98.326(o)] | 526.17 |
Length of time that substitute data are used for the temperature used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(o)] | |
P - Absolute Pressure used in Eq. FF-1 (atm) [§98.326(o)] | 0.79 |
Length of time that substitute data are used for the pressure used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(o)] | 0 |
Were the Quarterly Ventilation Flow Rate and Quarterly CH4 Concentration measured on the same basis? [§98.326(f)-(g)] | Flow rate was measured on a wet basis and CH4 concentration was measured on a dry basis |
Was a flow meter used? [§98.326(f)-(g)] | A flow meter was not used |
fH2O - Moisture content used in Eq. FF-1 (cubic feet water per cubic feet biogas) [§98.326(o)] | 0.0042 |
Length of time that substitute data are used for the moisture content used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(o)] | 0 |
Moisture correction factor used in Eq. FF-1 [§98.326(o)] | 0.9958 |
Length of time that substitute data are used for the moisture correction factor used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(o)] | 0 |
CH4V - Quarterly CH4 liberated from ventilation monitoring point (MT CH4) [§98.326(a)] --- Output of Eq. FF-1 | 0.79 |
File name of MSHA report used to report quarterly CH4 concentration and volumetric flow rate [§98.326(a)] | |
Ventilation Monitoring Point that corresponds to centralized monitoring point or individual shaft from previous tab [§98.326(l)] | Twentymile Five Main North Fan |
Quarter | 4 |
Dates where active ventilation of mining operations is taking place (MM/DD/YYYY) [§98.326(l)] - Start date | 2020-11-01 |
Stop date | 2020-11-30 |
Method used for flow rate [§98.326(f), (r), (s)] | Monitored using 98.324(b)(1) |
V - Quarterly volumetric flow rate used in Eq. FF-1 (acfm or scfm per selection in column A7) [§98.326(f)] | 923500 |
Specify units for parameter V, quarterly volumetric flow rate [§98.326(f)] | acfm |
Length of time that substitute data are used for the quarterly volumetric flow rate used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(f)] | 0 |
Location of each measurement of flow rate used in Eq. FF-1 [§98.326(f)] | Twentymile Five Main North Fan |
Date of each measurement of flow rate used in Eq. FF-1 (MM/DD/YYYY) [§98.326(f)] | 2020-11-30 |
Dates when continuous monitoring equipment for the flow rate is not properly functioning, if applicable (MM/DD/YYYY) [§98.326(n)] - Start date | |
Stop date | |
Method used for concentration [§98.326(g), (r), (s)] | Monitored using 98.324(b)(1) |
C - Quarterly CH4 concentration used in Eq. FF-1 (volume %) [§98.326(g)] | 0.0239 |
Was Eq. FF-9 required to calculate CH4 concentration? [§98.326(o)] | No |
If yes, provide the gaseous organic concentration correction factor, used in Eq. FF-9 [§98.326(o)] | |
Length of time that substitute data are used for the quarterly CH4 concentration (hours) [§98.3(c)(8), §98.326(g)] | 0 |
Location of each measurement of concentration [§98.326(g)] | Twentymile Five Main North Fan |
Date of each measurement of concentration (MM/DD/YYYY) [§98.326(g)] | 2020-11-30 |
Dates when continuous monitoring equipment for the concentration is not properly functioning, if applicable (MM/DD/YYYY) [§98.326(n)] - Start date | |
Stop date | |
T - Temperature used in Eq. FF-1 (°R) [§98.326(o)] | 515.97 |
Length of time that substitute data are used for the temperature used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(o)] | |
P - Absolute Pressure used in Eq. FF-1 (atm) [§98.326(o)] | 0.79 |
Length of time that substitute data are used for the pressure used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(o)] | 0 |
Were the Quarterly Ventilation Flow Rate and Quarterly CH4 Concentration measured on the same basis? [§98.326(f)-(g)] | Flow rate was measured on a wet basis and CH4 concentration was measured on a dry basis |
Was a flow meter used? [§98.326(f)-(g)] | A flow meter was not used |
fH2O - Moisture content used in Eq. FF-1 (cubic feet water per cubic feet biogas) [§98.326(o)] | 0.0057 |
Length of time that substitute data are used for the moisture content used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(o)] | 0 |
Moisture correction factor used in Eq. FF-1 [§98.326(o)] | 0.9943 |
Length of time that substitute data are used for the moisture correction factor used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(o)] | 0 |
CH4V - Quarterly CH4 liberated from ventilation monitoring point (MT CH4) [§98.326(a)] --- Output of Eq. FF-1 | 144.63 |
File name of MSHA report used to report quarterly CH4 concentration and volumetric flow rate [§98.326(a)] | |
Ventilation Monitoring Point that corresponds to centralized monitoring point or individual shaft from previous tab [§98.326(l)] | 9E Exhauster |
Quarter | 4 |
Dates where active ventilation of mining operations is taking place (MM/DD/YYYY) [§98.326(l)] - Start date | 2020-11-01 |
Stop date | 2020-11-30 |
Method used for flow rate [§98.326(f), (r), (s)] | Monitored using 98.324(b)(1) |
V - Quarterly volumetric flow rate used in Eq. FF-1 (acfm or scfm per selection in column A7) [§98.326(f)] | 3400 |
Specify units for parameter V, quarterly volumetric flow rate [§98.326(f)] | acfm |
Length of time that substitute data are used for the quarterly volumetric flow rate used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(f)] | 0 |
Location of each measurement of flow rate used in Eq. FF-1 [§98.326(f)] | 9E Exhauster |
Date of each measurement of flow rate used in Eq. FF-1 (MM/DD/YYYY) [§98.326(f)] | 2020-11-30 |
Dates when continuous monitoring equipment for the flow rate is not properly functioning, if applicable (MM/DD/YYYY) [§98.326(n)] - Start date | |
Stop date | |
Method used for concentration [§98.326(g), (r), (s)] | Monitored using 98.324(b)(1) |
C - Quarterly CH4 concentration used in Eq. FF-1 (volume %) [§98.326(g)] | 0.3074 |
Was Eq. FF-9 required to calculate CH4 concentration? [§98.326(o)] | No |
If yes, provide the gaseous organic concentration correction factor, used in Eq. FF-9 [§98.326(o)] | |
Length of time that substitute data are used for the quarterly CH4 concentration (hours) [§98.3(c)(8), §98.326(g)] | 0 |
Location of each measurement of concentration [§98.326(g)] | 9E Exhauster |
Date of each measurement of concentration (MM/DD/YYYY) [§98.326(g)] | 2020-11-30 |
Dates when continuous monitoring equipment for the concentration is not properly functioning, if applicable (MM/DD/YYYY) [§98.326(n)] - Start date | |
Stop date | |
T - Temperature used in Eq. FF-1 (°R) [§98.326(o)] | 511.47 |
Length of time that substitute data are used for the temperature used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(o)] | |
P - Absolute Pressure used in Eq. FF-1 (atm) [§98.326(o)] | 0.79 |
Length of time that substitute data are used for the pressure used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(o)] | 0 |
Were the Quarterly Ventilation Flow Rate and Quarterly CH4 Concentration measured on the same basis? [§98.326(f)-(g)] | Flow rate was measured on a wet basis and CH4 concentration was measured on a dry basis |
Was a flow meter used? [§98.326(f)-(g)] | A flow meter was not used |
fH2O - Moisture content used in Eq. FF-1 (cubic feet water per cubic feet biogas) [§98.326(o)] | 0.0026 |
Length of time that substitute data are used for the moisture content used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(o)] | 0 |
Moisture correction factor used in Eq. FF-1 [§98.326(o)] | 0.9974 |
Length of time that substitute data are used for the moisture correction factor used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(o)] | 0 |
CH4V - Quarterly CH4 liberated from ventilation monitoring point (MT CH4) [§98.326(a)] --- Output of Eq. FF-1 | 6.93 |
File name of MSHA report used to report quarterly CH4 concentration and volumetric flow rate [§98.326(a)] | |
Ventilation Monitoring Point that corresponds to centralized monitoring point or individual shaft from previous tab [§98.326(l)] | Twentymile Five Main North Fan |
Quarter | 4 |
Dates where active ventilation of mining operations is taking place (MM/DD/YYYY) [§98.326(l)] - Start date | 2020-12-01 |
Stop date | 2020-12-31 |
Method used for flow rate [§98.326(f), (r), (s)] | Monitored using 98.324(b)(1) |
V - Quarterly volumetric flow rate used in Eq. FF-1 (acfm or scfm per selection in column A7) [§98.326(f)] | 841900 |
Specify units for parameter V, quarterly volumetric flow rate [§98.326(f)] | acfm |
Length of time that substitute data are used for the quarterly volumetric flow rate used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(f)] | 0 |
Location of each measurement of flow rate used in Eq. FF-1 [§98.326(f)] | Twentymile Five Main North Fan |
Date of each measurement of flow rate used in Eq. FF-1 (MM/DD/YYYY) [§98.326(f)] | 2020-12-31 |
Dates when continuous monitoring equipment for the flow rate is not properly functioning, if applicable (MM/DD/YYYY) [§98.326(n)] - Start date | |
Stop date | |
Method used for concentration [§98.326(g), (r), (s)] | Monitored using 98.324(b)(1) |
C - Quarterly CH4 concentration used in Eq. FF-1 (volume %) [§98.326(g)] | 0 |
Was Eq. FF-9 required to calculate CH4 concentration? [§98.326(o)] | No |
If yes, provide the gaseous organic concentration correction factor, used in Eq. FF-9 [§98.326(o)] | |
Length of time that substitute data are used for the quarterly CH4 concentration (hours) [§98.3(c)(8), §98.326(g)] | 0 |
Location of each measurement of concentration [§98.326(g)] | Twentymile Five Main North Fan |
Date of each measurement of concentration (MM/DD/YYYY) [§98.326(g)] | 2020-12-31 |
Dates when continuous monitoring equipment for the concentration is not properly functioning, if applicable (MM/DD/YYYY) [§98.326(n)] - Start date | |
Stop date | |
T - Temperature used in Eq. FF-1 (°R) [§98.326(o)] | 515.67 |
Length of time that substitute data are used for the temperature used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(o)] | 744 |
P - Absolute Pressure used in Eq. FF-1 (atm) [§98.326(o)] | 0.78 |
Length of time that substitute data are used for the pressure used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(o)] | 0 |
Were the Quarterly Ventilation Flow Rate and Quarterly CH4 Concentration measured on the same basis? [§98.326(f)-(g)] | Flow rate was measured on a wet basis and CH4 concentration was measured on a dry basis |
Was a flow meter used? [§98.326(f)-(g)] | A flow meter was not used |
fH2O - Moisture content used in Eq. FF-1 (cubic feet water per cubic feet biogas) [§98.326(o)] | 0.0057 |
Length of time that substitute data are used for the moisture content used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(o)] | 744 |
Moisture correction factor used in Eq. FF-1 [§98.326(o)] | 0.9943 |
Length of time that substitute data are used for the moisture correction factor used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(o)] | 0 |
CH4V - Quarterly CH4 liberated from ventilation monitoring point (MT CH4) [§98.326(a)] --- Output of Eq. FF-1 | 0 |
File name of MSHA report used to report quarterly CH4 concentration and volumetric flow rate [§98.326(a)] | |
Ventilation Monitoring Point that corresponds to centralized monitoring point or individual shaft from previous tab [§98.326(l)] | 9E Exhauster |
Quarter | 4 |
Dates where active ventilation of mining operations is taking place (MM/DD/YYYY) [§98.326(l)] - Start date | 2020-12-01 |
Stop date | 2020-12-31 |
Method used for flow rate [§98.326(f), (r), (s)] | Monitored using 98.324(b)(1) |
V - Quarterly volumetric flow rate used in Eq. FF-1 (acfm or scfm per selection in column A7) [§98.326(f)] | 5800 |
Specify units for parameter V, quarterly volumetric flow rate [§98.326(f)] | acfm |
Length of time that substitute data are used for the quarterly volumetric flow rate used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(f)] | 0 |
Location of each measurement of flow rate used in Eq. FF-1 [§98.326(f)] | 9E Exhauster |
Date of each measurement of flow rate used in Eq. FF-1 (MM/DD/YYYY) [§98.326(f)] | 2020-12-31 |
Dates when continuous monitoring equipment for the flow rate is not properly functioning, if applicable (MM/DD/YYYY) [§98.326(n)] - Start date | |
Stop date | |
Method used for concentration [§98.326(g), (r), (s)] | |
C - Quarterly CH4 concentration used in Eq. FF-1 (volume %) [§98.326(g)] | 0.0092 |
Was Eq. FF-9 required to calculate CH4 concentration? [§98.326(o)] | No |
If yes, provide the gaseous organic concentration correction factor, used in Eq. FF-9 [§98.326(o)] | |
Length of time that substitute data are used for the quarterly CH4 concentration (hours) [§98.3(c)(8), §98.326(g)] | 0 |
Location of each measurement of concentration [§98.326(g)] | 9E Exhauster |
Date of each measurement of concentration (MM/DD/YYYY) [§98.326(g)] | 2020-12-31 |
Dates when continuous monitoring equipment for the concentration is not properly functioning, if applicable (MM/DD/YYYY) [§98.326(n)] - Start date | |
Stop date | |
T - Temperature used in Eq. FF-1 (°R) [§98.326(o)] | 511.47 |
Length of time that substitute data are used for the temperature used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(o)] | 744 |
P - Absolute Pressure used in Eq. FF-1 (atm) [§98.326(o)] | 0.78 |
Length of time that substitute data are used for the pressure used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(o)] | 0 |
Were the Quarterly Ventilation Flow Rate and Quarterly CH4 Concentration measured on the same basis? [§98.326(f)-(g)] | Flow rate was measured on a wet basis and CH4 concentration was measured on a dry basis |
Was a flow meter used? [§98.326(f)-(g)] | A flow meter was not used |
fH2O - Moisture content used in Eq. FF-1 (cubic feet water per cubic feet biogas) [§98.326(o)] | 0.0027 |
Length of time that substitute data are used for the moisture content used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(o)] | 744 |
Moisture correction factor used in Eq. FF-1 [§98.326(o)] | 0.9973 |
Length of time that substitute data are used for the moisture correction factor used in Eq. FF-1 (hours) [§98.3(c)(8), §98.326(o)] | 0 |
CH4V - Quarterly CH4 liberated from ventilation monitoring point (MT CH4) [§98.326(a)] --- Output of Eq. FF-1 | 0.36 |
File name of MSHA report used to report quarterly CH4 concentration and volumetric flow rate [§98.326(a)] | |