Source Reporting Form | Onshore Production [98.236(aa)(1)] |
Required for Selected Industry Segment | No |
Source Reporting Form | Facility Overview [98.236(aa)(2-11)] |
Required for Selected Industry Segment | Yes |
Source Reporting Form | Natural Gas Pneumatic Devices [98.236(b)] |
Required for Selected Industry Segment | Yes |
Total Reported CO2 Emissions (mt CO2) | 0.0 |
Total Reported CH4 Emissions (mt CH4) | 0.00 |
Source Reporting Form | Natural Gas Driven Pneumatic Pumps [98.236(c)] |
Required for Selected Industry Segment | No |
Total Reported CO2 Emissions (mt CO2) | 0.0 |
Total Reported CH4 Emissions (mt CH4) | 0.00 |
Source Reporting Form | Acid Gas Removal Units [98.236(d)] |
Required for Selected Industry Segment | No |
Total Reported CO2 Emissions (mt CO2) | 0.0 |
Source Reporting Form | Dehydrators [98.236(e)] |
Required for Selected Industry Segment | No |
Total Reported CO2 Emissions (mt CO2) | 0.0 |
Total Reported CH4 Emissions (mt CH4) | 0.00 |
Total Reported N2O Emissions (mt N2O) | 0.000 |
Source Reporting Form | Well Venting for Liquids Unloading [98.236(f)] |
Required for Selected Industry Segment | No |
Total Reported CO2 Emissions (mt CO2) | 0.0 |
Total Reported CH4 Emissions (mt CH4) | 0.00 |
Source Reporting Form | Completions and Workovers with Hydraulic Fracturing [98.236(g)] |
Required for Selected Industry Segment | No |
Total Reported CO2 Emissions (mt CO2) | 0.0 |
Total Reported CH4 Emissions (mt CH4) | 0.00 |
Total Reported N2O Emissions (mt N2O) | 0.000 |
Source Reporting Form | Completions and Workovers without Hydraulic Fracturing [98.236(h)] |
Required for Selected Industry Segment | No |
Total Reported CO2 Emissions (mt CO2) | 0.0 |
Total Reported CH4 Emissions (mt CH4) | 0.00 |
Total Reported N2O Emissions (mt N2O) | 0.000 |
Source Reporting Form | Blowdown Vent Stacks [98.236(i)] |
Required for Selected Industry Segment | Yes |
Total Reported CO2 Emissions (mt CO2) | 0.8 |
Total Reported CH4 Emissions (mt CH4) | 28.58 |
Source Reporting Form | Atmospheric Storage Tanks [98.236(j)] |
Required for Selected Industry Segment | No |
Total Reported CO2 Emissions (mt CO2) | 0.0 |
Total Reported CH4 Emissions (mt CH4) | 0.00 |
Total Reported N2O Emissions (mt N2O) | 0.000 |
Source Reporting Form | Transmission Storage Tanks [98.236(k)] |
Required for Selected Industry Segment | Yes |
Total Reported CO2 Emissions (mt CO2) | 0.0 |
Total Reported CH4 Emissions (mt CH4) | 0.00 |
Total Reported N2O Emissions (mt N2O) | 0.000 |
Source Reporting Form | Well Testing [98.236(l)] |
Required for Selected Industry Segment | No |
Total Reported CO2 Emissions (mt CO2) | 0.0 |
Total Reported CH4 Emissions (mt CH4) | 0.00 |
Total Reported N2O Emissions (mt N2O) | 0.000 |
Source Reporting Form | Associated Gas Venting and Flaring [98.236(m)] |
Required for Selected Industry Segment | No |
Total Reported CO2 Emissions (mt CO2) | 0.0 |
Total Reported CH4 Emissions (mt CH4) | 0.00 |
Total Reported N2O Emissions (mt N2O) | 0.000 |
Source Reporting Form | Flare Stacks [98.236(n)] |
Required for Selected Industry Segment | Yes |
Total Reported CO2 Emissions (mt CO2) | 0.0 |
Total Reported CH4 Emissions (mt CH4) | 0.00 |
Total Reported N2O Emissions (mt N2O) | 0.000 |
Source Reporting Form | Centrifugal Compressors [98.236(o)] |
Required for Selected Industry Segment | Yes |
Total Reported CO2 Emissions (mt CO2) | 0.0 |
Total Reported CH4 Emissions (mt CH4) | 0.00 |
Source Reporting Form | Reciprocating Compressors [98.236(p)] |
Required for Selected Industry Segment | Yes |
Total Reported CO2 Emissions (mt CO2) | 4.9 |
Total Reported CH4 Emissions (mt CH4) | 169.34 |
Source Reporting Form | Equipment Leaks Surveys and Population Counts [98.236(q,r)] |
Required for Selected Industry Segment | Yes |
Total Reported CO2 Emissions (mt CO2) | 0.1 |
Total Reported CH4 Emissions (mt CH4) | 3.17 |
Source Reporting Form | Offshore Petroleum and Natural Gas Production [98.236(s)] |
Required for Selected Industry Segment | No |
Total Reported CO2 Emissions (mt CO2) | 0.0 |
Total Reported CH4 Emissions (mt CH4) | 0.00 |
Total Reported N2O Emissions (mt N2O) | 0.000 |
Source Reporting Form | Enhanced Oil Recovery Injection Pumps [98.236(w)] |
Required for Selected Industry Segment | No |
Total Reported CO2 Emissions (mt CO2) | 0.0 |
Source Reporting Form | Enhanced Oil Recovery Hydrocarbon Liquids [98.236(x)] |
Required for Selected Industry Segment | No |
Total Reported CO2 Emissions (mt CO2) | 0.0 |
Source Reporting Form | Combustion Equipment at Onshore Petroleum and Natural Gas Production Facilities, Onshore Petroleum and Natural Gas Gathering and Boosting Facilities, and Natural gas Distribution Facilities [98.236(z)] |
Required for Selected Industry Segment | No |
Total Reported CO2 Emissions (mt CO2) | 0.0 |
Total Reported CH4 Emissions (mt CH4) | 0.00 |
Total Reported N2O Emissions (mt N2O) | 0.000 |
Unique name or ID for reciprocating compressor [98.236(p)(1)(i)] | Compressor A-04 |
Total time in operating-mode (hours) [98.236(p)(1)(ii)] | 1151.75 |
Total time in standby-pressurized-mode (hours) [98.236(p)(1)(iii)] | 0 |
Total time in not-operating-depressurized-mode (hours) [98.236(p)(1)(iv)] | 7632.25 |
Compressor measured in operating-mode? [98.236(p)(1)(v)] | No |
Compressor measured in standby-pressurized-mode? [98.236(p)(1)(vi)] | No |
Compressor measured in not-operating-depressurized-mode? [98.236(p)(1)(vii)] | Yes |
Compressor had blind flanges installed? [98.236(p)(1)(xii)] | No |
Power output of compressor driver (hp) [98.236(p)(1)(xiii)] | 660 |
Compressor had scheduled depressurized shutdown during reporting year? [98.236(p)(1)(xiv)] | Yes |
Unique name or ID for reciprocating compressor [98.236(p)(1)(i)] | Compressor A-05 |
Total time in operating-mode (hours) [98.236(p)(1)(ii)] | 454.25 |
Total time in standby-pressurized-mode (hours) [98.236(p)(1)(iii)] | 0 |
Total time in not-operating-depressurized-mode (hours) [98.236(p)(1)(iv)] | 8329.75 |
Compressor measured in operating-mode? [98.236(p)(1)(v)] | No |
Compressor measured in standby-pressurized-mode? [98.236(p)(1)(vi)] | No |
Compressor measured in not-operating-depressurized-mode? [98.236(p)(1)(vii)] | Yes |
Compressor had blind flanges installed? [98.236(p)(1)(xii)] | No |
Power output of compressor driver (hp) [98.236(p)(1)(xiii)] | 660 |
Compressor had scheduled depressurized shutdown during reporting year? [98.236(p)(1)(xiv)] | Yes |
Unique name or ID for reciprocating compressor [98.236(p)(1)(i)] | Compressor A-06 |
Total time in operating-mode (hours) [98.236(p)(1)(ii)] | 1577.5 |
Total time in standby-pressurized-mode (hours) [98.236(p)(1)(iii)] | 0 |
Total time in not-operating-depressurized-mode (hours) [98.236(p)(1)(iv)] | 7206.5 |
Compressor measured in operating-mode? [98.236(p)(1)(v)] | No |
Compressor measured in standby-pressurized-mode? [98.236(p)(1)(vi)] | No |
Compressor measured in not-operating-depressurized-mode? [98.236(p)(1)(vii)] | Yes |
Compressor had blind flanges installed? [98.236(p)(1)(xii)] | No |
Power output of compressor driver (hp) [98.236(p)(1)(xiii)] | 660 |
Compressor had scheduled depressurized shutdown during reporting year? [98.236(p)(1)(xiv)] | Yes |
Unique name or ID for reciprocating compressor [98.236(p)(1)(i)] | Compressor A-07 |
Total time in operating-mode (hours) [98.236(p)(1)(ii)] | 872.75 |
Total time in standby-pressurized-mode (hours) [98.236(p)(1)(iii)] | 0 |
Total time in not-operating-depressurized-mode (hours) [98.236(p)(1)(iv)] | 7911.25 |
Compressor measured in operating-mode? [98.236(p)(1)(v)] | No |
Compressor measured in standby-pressurized-mode? [98.236(p)(1)(vi)] | No |
Compressor measured in not-operating-depressurized-mode? [98.236(p)(1)(vii)] | Yes |
Compressor had blind flanges installed? [98.236(p)(1)(xii)] | No |
Power output of compressor driver (hp) [98.236(p)(1)(xiii)] | 660 |
Compressor had scheduled depressurized shutdown during reporting year? [98.236(p)(1)(xiv)] | Yes |
Unique name or ID for reciprocating compressor [98.236(p)(1)(i)] | Compressor A-08 |
Total time in operating-mode (hours) [98.236(p)(1)(ii)] | 1110.5 |
Total time in standby-pressurized-mode (hours) [98.236(p)(1)(iii)] | 0 |
Total time in not-operating-depressurized-mode (hours) [98.236(p)(1)(iv)] | 7673.5 |
Compressor measured in operating-mode? [98.236(p)(1)(v)] | No |
Compressor measured in standby-pressurized-mode? [98.236(p)(1)(vi)] | No |
Compressor measured in not-operating-depressurized-mode? [98.236(p)(1)(vii)] | Yes |
Compressor had blind flanges installed? [98.236(p)(1)(xii)] | No |
Power output of compressor driver (hp) [98.236(p)(1)(xiii)] | 660 |
Compressor had scheduled depressurized shutdown during reporting year? [98.236(p)(1)(xiv)] | Yes |
Unique name or ID for reciprocating compressor [98.236(p)(1)(i)] | Compressor A-09 |
Total time in operating-mode (hours) [98.236(p)(1)(ii)] | 2495 |
Total time in standby-pressurized-mode (hours) [98.236(p)(1)(iii)] | 0 |
Total time in not-operating-depressurized-mode (hours) [98.236(p)(1)(iv)] | 6289 |
Compressor measured in operating-mode? [98.236(p)(1)(v)] | No |
Compressor measured in standby-pressurized-mode? [98.236(p)(1)(vi)] | No |
Compressor measured in not-operating-depressurized-mode? [98.236(p)(1)(vii)] | Yes |
Compressor had blind flanges installed? [98.236(p)(1)(xii)] | No |
Power output of compressor driver (hp) [98.236(p)(1)(xiii)] | 1350 |
Compressor had scheduled depressurized shutdown during reporting year? [98.236(p)(1)(xiv)] | Yes |
Unique name or ID for reciprocating compressor [98.236(p)(1)(i)] | Compressor A-10 |
Total time in operating-mode (hours) [98.236(p)(1)(ii)] | 2528.25 |
Total time in standby-pressurized-mode (hours) [98.236(p)(1)(iii)] | 0 |
Total time in not-operating-depressurized-mode (hours) [98.236(p)(1)(iv)] | 6255.75 |
Compressor measured in operating-mode? [98.236(p)(1)(v)] | No |
Compressor measured in standby-pressurized-mode? [98.236(p)(1)(vi)] | No |
Compressor measured in not-operating-depressurized-mode? [98.236(p)(1)(vii)] | Yes |
Compressor had blind flanges installed? [98.236(p)(1)(xii)] | No |
Power output of compressor driver (hp) [98.236(p)(1)(xiii)] | 1350 |
Compressor had scheduled depressurized shutdown during reporting year? [98.236(p)(1)(xiv)] | Yes |
Unique name or ID for reciprocating compressor [98.236(p)(1)(i)] | Compressor A-11 |
Total time in operating-mode (hours) [98.236(p)(1)(ii)] | 1608.75 |
Total time in standby-pressurized-mode (hours) [98.236(p)(1)(iii)] | 0 |
Total time in not-operating-depressurized-mode (hours) [98.236(p)(1)(iv)] | 7175.25 |
Compressor measured in operating-mode? [98.236(p)(1)(v)] | No |
Compressor measured in standby-pressurized-mode? [98.236(p)(1)(vi)] | No |
Compressor measured in not-operating-depressurized-mode? [98.236(p)(1)(vii)] | Yes |
Compressor had blind flanges installed? [98.236(p)(1)(xii)] | No |
Power output of compressor driver (hp) [98.236(p)(1)(xiii)] | 1350 |
Compressor had scheduled depressurized shutdown during reporting year? [98.236(p)(1)(xiv)] | Yes |
Unique name or ID for reciprocating compressor [98.236(p)(1)(i)] | Compressor A-15 |
Total time in operating-mode (hours) [98.236(p)(1)(ii)] | 484.5 |
Total time in standby-pressurized-mode (hours) [98.236(p)(1)(iii)] | 0 |
Total time in not-operating-depressurized-mode (hours) [98.236(p)(1)(iv)] | 8299.5 |
Compressor measured in operating-mode? [98.236(p)(1)(v)] | No |
Compressor measured in standby-pressurized-mode? [98.236(p)(1)(vi)] | No |
Compressor measured in not-operating-depressurized-mode? [98.236(p)(1)(vii)] | Yes |
Compressor had blind flanges installed? [98.236(p)(1)(xii)] | No |
Power output of compressor driver (hp) [98.236(p)(1)(xiii)] | 5000 |
Compressor had scheduled depressurized shutdown during reporting year? [98.236(p)(1)(xiv)] | Yes |
Unique name or ID for reciprocating compressor [98.236(p)(1)(i)] | Compressor B-16 |
Total time in operating-mode (hours) [98.236(p)(1)(ii)] | 3032 |
Total time in standby-pressurized-mode (hours) [98.236(p)(1)(iii)] | 0 |
Total time in not-operating-depressurized-mode (hours) [98.236(p)(1)(iv)] | 5752 |
Compressor measured in operating-mode? [98.236(p)(1)(v)] | No |
Compressor measured in standby-pressurized-mode? [98.236(p)(1)(vi)] | No |
Compressor measured in not-operating-depressurized-mode? [98.236(p)(1)(vii)] | Yes |
Compressor had blind flanges installed? [98.236(p)(1)(xii)] | No |
Power output of compressor driver (hp) [98.236(p)(1)(xiii)] | 4400 |
Compressor had scheduled depressurized shutdown during reporting year? [98.236(p)(1)(xiv)] | Yes |
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)] | Compressor A-04 |
Reciprocating compressor source [98.236(p)(2)(i)(B)] | Blowdown valve |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | Compressor A-04-BV |
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)] | Compressor A-04 |
Reciprocating compressor source [98.236(p)(2)(i)(B)] | Isolation valve |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | Compressor A-04-IV |
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)] | Compressor A-04 |
Reciprocating compressor source [98.236(p)(2)(i)(B)] | Rod packing |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | Compressor A-04-RP |
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)] | Compressor A-05 |
Reciprocating compressor source [98.236(p)(2)(i)(B)] | Blowdown valve |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | Compressor A-05-BV |
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)] | Compressor A-05 |
Reciprocating compressor source [98.236(p)(2)(i)(B)] | Isolation valve |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | Compressor A-05-IV |
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)] | Compressor A-05 |
Reciprocating compressor source [98.236(p)(2)(i)(B)] | Rod packing |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | Compressor A-05-RP |
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)] | Compressor A-06 |
Reciprocating compressor source [98.236(p)(2)(i)(B)] | Blowdown valve |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | Compressor A-06-BV |
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)] | Compressor A-06 |
Reciprocating compressor source [98.236(p)(2)(i)(B)] | Isolation valve |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | Compressor A-06-IV |
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)] | Compressor A-06 |
Reciprocating compressor source [98.236(p)(2)(i)(B)] | Rod packing |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | Compressor A-06-RP |
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)] | Compressor A-07 |
Reciprocating compressor source [98.236(p)(2)(i)(B)] | Blowdown valve |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | Compressor A-07-BV |
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)] | Compressor A-07 |
Reciprocating compressor source [98.236(p)(2)(i)(B)] | Isolation valve |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | Compressor A-07-IV |
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)] | Compressor A-07 |
Reciprocating compressor source [98.236(p)(2)(i)(B)] | Rod packing |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | Compressor A-07-RP |
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)] | Compressor A-08 |
Reciprocating compressor source [98.236(p)(2)(i)(B)] | Blowdown valve |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | Compressor A-08-BV |
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)] | Compressor A-08 |
Reciprocating compressor source [98.236(p)(2)(i)(B)] | Isolation valve |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | Compressor A-08-IV |
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)] | Compressor A-08 |
Reciprocating compressor source [98.236(p)(2)(i)(B)] | Rod packing |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | Compressor A-08-RP |
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)] | Compressor A-09 |
Reciprocating compressor source [98.236(p)(2)(i)(B)] | Blowdown valve |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | Compressor A-09-BV |
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)] | Compressor A-09 |
Reciprocating compressor source [98.236(p)(2)(i)(B)] | Isolation valve |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | Compressor A-09-IV |
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)] | Compressor A-09 |
Reciprocating compressor source [98.236(p)(2)(i)(B)] | Rod packing |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | Compressor A-09-RP |
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)] | Compressor A-10 |
Reciprocating compressor source [98.236(p)(2)(i)(B)] | Blowdown valve |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | Compressor A-10-BV |
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)] | Compressor A-10 |
Reciprocating compressor source [98.236(p)(2)(i)(B)] | Isolation valve |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | Compressor A-10-IV |
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)] | Compressor A-10 |
Reciprocating compressor source [98.236(p)(2)(i)(B)] | Rod packing |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | Compressor A-10-RP |
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)] | Compressor A-11 |
Reciprocating compressor source [98.236(p)(2)(i)(B)] | Blowdown valve |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | Compressor A-11-BV |
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)] | Compressor A-11 |
Reciprocating compressor source [98.236(p)(2)(i)(B)] | Isolation valve |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | Compressor A-11-IV |
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)] | Compressor A-11 |
Reciprocating compressor source [98.236(p)(2)(i)(B)] | Rod packing |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | Compressor A-11-RP |
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)] | Compressor A-15 |
Reciprocating compressor source [98.236(p)(2)(i)(B)] | Blowdown valve |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | Compressor A-15-BV |
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)] | Compressor A-15 |
Reciprocating compressor source [98.236(p)(2)(i)(B)] | Isolation valve |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | Compressor A-15-IV |
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)] | Compressor A-15 |
Reciprocating compressor source [98.236(p)(2)(i)(B)] | Rod packing |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | Compressor A-15-RP |
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)] | Compressor B-16 |
Reciprocating compressor source [98.236(p)(2)(i)(B)] | Blowdown valve |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | Compressor B-16-BV |
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)] | Compressor B-16 |
Reciprocating compressor source [98.236(p)(2)(i)(B)] | Isolation valve |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | Compressor B-16-IV |
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)] | Compressor B-16 |
Reciprocating compressor source [98.236(p)(2)(i)(B)] | Rod packing |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | Compressor B-16-RP |
Unique Name or ID for leak or vent (Specify) [98.236(p)(2)(i)(C)] [98.236(p)(3)(i)(A)] | Compressor A-04-IV |
Measurement date (mm/dd/yyyy) [98.236(p)(3)(i)(B)] | 2020-10-15 |
Measurement method [98.236(p)(3)(i)(C)] | High volume sampler |
Measured flow rate (standard cubic feet/hour) [98.236(p)(3)(i)(D)] | 19.8 |
Is the measurement location prior to or after commingling with non-compressor emission sources? [98.236(p)(3)(i)(F)] | Not manifolded |
Compressors in “Not-operating mode” | Compressor A-04 |
Unique Name or ID for leak or vent (Specify) [98.236(p)(2)(i)(C)] [98.236(p)(3)(i)(A)] | Compressor A-05-IV |
Measurement date (mm/dd/yyyy) [98.236(p)(3)(i)(B)] | 2020-10-15 |
Measurement method [98.236(p)(3)(i)(C)] | High volume sampler |
Measured flow rate (standard cubic feet/hour) [98.236(p)(3)(i)(D)] | 12.6 |
Is the measurement location prior to or after commingling with non-compressor emission sources? [98.236(p)(3)(i)(F)] | Not manifolded |
Compressors in “Not-operating mode” | Compressor A-05 |
Unique Name or ID for leak or vent (Specify) [98.236(p)(2)(i)(C)] [98.236(p)(3)(i)(A)] | Compressor A-06-IV |
Measurement date (mm/dd/yyyy) [98.236(p)(3)(i)(B)] | 2020-10-15 |
Measurement method [98.236(p)(3)(i)(C)] | High volume sampler |
Measured flow rate (standard cubic feet/hour) [98.236(p)(3)(i)(D)] | 15 |
Is the measurement location prior to or after commingling with non-compressor emission sources? [98.236(p)(3)(i)(F)] | Not manifolded |
Compressors in “Not-operating mode” | Compressor A-06 |
Unique Name or ID for leak or vent (Specify) [98.236(p)(2)(i)(C)] [98.236(p)(3)(i)(A)] | Compressor A-07-IV |
Measurement date (mm/dd/yyyy) [98.236(p)(3)(i)(B)] | 2020-10-15 |
Measurement method [98.236(p)(3)(i)(C)] | High volume sampler |
Measured flow rate (standard cubic feet/hour) [98.236(p)(3)(i)(D)] | 13.2 |
Is the measurement location prior to or after commingling with non-compressor emission sources? [98.236(p)(3)(i)(F)] | Not manifolded |
Compressors in “Not-operating mode” | Compressor A-07 |
Unique Name or ID for leak or vent (Specify) [98.236(p)(2)(i)(C)] [98.236(p)(3)(i)(A)] | Compressor A-08-IV |
Measurement date (mm/dd/yyyy) [98.236(p)(3)(i)(B)] | 2020-10-15 |
Measurement method [98.236(p)(3)(i)(C)] | High volume sampler |
Measured flow rate (standard cubic feet/hour) [98.236(p)(3)(i)(D)] | 184.2 |
Is the measurement location prior to or after commingling with non-compressor emission sources? [98.236(p)(3)(i)(F)] | Not manifolded |
Compressors in “Not-operating mode” | Compressor A-08 |
Unique Name or ID for leak or vent (Specify) [98.236(p)(2)(i)(C)] [98.236(p)(3)(i)(A)] | Compressor A-09-IV |
Measurement date (mm/dd/yyyy) [98.236(p)(3)(i)(B)] | 2020-10-15 |
Measurement method [98.236(p)(3)(i)(C)] | High volume sampler |
Measured flow rate (standard cubic feet/hour) [98.236(p)(3)(i)(D)] | 204.6 |
Is the measurement location prior to or after commingling with non-compressor emission sources? [98.236(p)(3)(i)(F)] | Not manifolded |
Compressors in “Not-operating mode” | Compressor A-09 |
Unique Name or ID for leak or vent (Specify) [98.236(p)(2)(i)(C)] [98.236(p)(3)(i)(A)] | Compressor A-10-IV |
Measurement date (mm/dd/yyyy) [98.236(p)(3)(i)(B)] | 2020-10-15 |
Measurement method [98.236(p)(3)(i)(C)] | High volume sampler |
Measured flow rate (standard cubic feet/hour) [98.236(p)(3)(i)(D)] | 280.2 |
Is the measurement location prior to or after commingling with non-compressor emission sources? [98.236(p)(3)(i)(F)] | Not manifolded |
Compressors in “Not-operating mode” | Compressor A-10 |
Unique Name or ID for leak or vent (Specify) [98.236(p)(2)(i)(C)] [98.236(p)(3)(i)(A)] | Compressor A-11-IV |
Measurement date (mm/dd/yyyy) [98.236(p)(3)(i)(B)] | 2020-10-15 |
Measurement method [98.236(p)(3)(i)(C)] | High volume sampler |
Measured flow rate (standard cubic feet/hour) [98.236(p)(3)(i)(D)] | 1.2 |
Is the measurement location prior to or after commingling with non-compressor emission sources? [98.236(p)(3)(i)(F)] | Not manifolded |
Compressors in “Not-operating mode” | Compressor A-11 |
Unique Name or ID for leak or vent (Specify) [98.236(p)(2)(i)(C)] [98.236(p)(3)(i)(A)] | Compressor A-15-IV |
Measurement date (mm/dd/yyyy) [98.236(p)(3)(i)(B)] | 2020-10-15 |
Measurement method [98.236(p)(3)(i)(C)] | High volume sampler |
Measured flow rate (standard cubic feet/hour) [98.236(p)(3)(i)(D)] | 21 |
Is the measurement location prior to or after commingling with non-compressor emission sources? [98.236(p)(3)(i)(F)] | Not manifolded |
Compressors in “Not-operating mode” | Compressor A-15 |
Unique Name or ID for leak or vent (Specify) [98.236(p)(2)(i)(C)] [98.236(p)(3)(i)(A)] | Compressor B-16-IV |
Measurement date (mm/dd/yyyy) [98.236(p)(3)(i)(B)] | 2020-10-15 |
Measurement method [98.236(p)(3)(i)(C)] | High volume sampler |
Measured flow rate (standard cubic feet/hour) [98.236(p)(3)(i)(D)] | 94.2 |
Is the measurement location prior to or after commingling with non-compressor emission sources? [98.236(p)(3)(i)(F)] | Not manifolded |
Compressors in “Not-operating mode” | Compressor B-16 |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | Compressor A-04-BV |
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)] | Single |
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)] | Atmosphere |
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)] | No |
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)] | No |
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)] | 0.0178487 |
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)] | 0.618935 |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | Compressor A-04-IV |
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)] | Single |
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)] | Atmosphere |
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)] | Yes |
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)] | No |
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)] | 0.0794884 |
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)] | 2.7564024 |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | Compressor A-04-RP |
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)] | Single |
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)] | Atmosphere |
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)] | No |
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)] | No |
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)] | 0.1260401 |
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)] | 4.3706673 |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | Compressor A-05-BV |
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)] | Single |
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)] | Atmosphere |
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)] | No |
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)] | No |
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)] | 0.0070395 |
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)] | 0.2441079 |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | Compressor A-05-IV |
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)] | Single |
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)] | Atmosphere |
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)] | Yes |
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)] | No |
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)] | 0.0552063 |
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)] | 1.9143765 |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | Compressor A-05-RP |
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)] | Single |
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)] | Atmosphere |
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)] | No |
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)] | No |
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)] | 0.0497102 |
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)] | 1.7237904 |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | Compressor A-06-BV |
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)] | Single |
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)] | Atmosphere |
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)] | No |
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)] | No |
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)] | 0.0244465 |
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)] | 0.8477274 |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | Compressor A-06-IV |
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)] | Single |
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)] | Atmosphere |
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)] | Yes |
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)] | No |
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)] | 0.0568593 |
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)] | 1.9716984 |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | Compressor A-06-RP |
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)] | Single |
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)] | Atmosphere |
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)] | No |
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)] | No |
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)] | 0.1726314 |
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)] | 5.9863057 |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | Compressor A-07-BV |
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)] | Single |
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)] | Atmosphere |
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)] | No |
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)] | No |
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)] | 0.013525 |
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)] | 0.4690042 |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | Compressor A-07-IV |
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)] | Single |
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)] | Atmosphere |
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)] | Yes |
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)] | No |
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)] | 0.0549294 |
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)] | 1.9047758 |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | Compressor A-07-RP |
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)] | Single |
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)] | Atmosphere |
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)] | No |
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)] | No |
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)] | 0.0955081 |
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)] | 3.3119165 |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | Compressor A-08-BV |
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)] | Single |
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)] | Atmosphere |
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)] | No |
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)] | No |
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)] | 0.0172094 |
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)] | 0.5967678 |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | Compressor A-08-IV |
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)] | Single |
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)] | Atmosphere |
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)] | Yes |
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)] | No |
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)] | 0.7434793 |
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)] | 25.7814867 |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | Compressor A-08-RP |
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)] | Single |
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)] | Atmosphere |
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)] | No |
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)] | No |
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)] | 0.1215259 |
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)] | 4.2141316 |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | Compressor A-09-BV |
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)] | Single |
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)] | Atmosphere |
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)] | No |
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)] | No |
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)] | 0.038665 |
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)] | 1.3407796 |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | Compressor A-09-IV |
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)] | Single |
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)] | Atmosphere |
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)] | Yes |
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)] | No |
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)] | 0.6768197 |
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)] | 23.4699443 |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | Compressor A-09-RP |
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)] | Single |
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)] | Atmosphere |
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)] | No |
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)] | No |
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)] | 0.2730367 |
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)] | 9.4680398 |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | Compressor A-10-BV |
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)] | Single |
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)] | Atmosphere |
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)] | No |
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)] | No |
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)] | 0.0391803 |
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)] | 1.3586477 |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | Compressor A-10-IV |
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)] | Single |
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)] | Atmosphere |
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)] | Yes |
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)] | No |
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)] | 0.922005 |
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)] | 31.9721874 |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | Compressor A-10-RP |
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)] | Single |
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)] | Atmosphere |
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)] | No |
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)] | No |
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)] | 0.2766753 |
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)] | 9.5942171 |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | Compressor A-11-BV |
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)] | Single |
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)] | Atmosphere |
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)] | No |
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)] | No |
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)] | 0.0249308 |
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)] | 0.8645207 |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | Compressor A-11-IV |
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)] | Single |
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)] | Atmosphere |
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)] | Yes |
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)] | No |
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)] | 0.004529 |
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)] | 0.1570519 |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | Compressor A-11-RP |
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)] | Single |
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)] | Atmosphere |
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)] | No |
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)] | No |
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)] | 0.1760512 |
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)] | 6.1048934 |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | Compressor A-15-BV |
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)] | Single |
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)] | Atmosphere |
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)] | No |
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)] | No |
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)] | 0.0075083 |
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)] | 0.2603638 |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | Compressor A-15-IV |
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)] | Single |
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)] | Atmosphere |
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)] | Yes |
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)] | No |
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)] | 0.0916763 |
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)] | 3.1790405 |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | Compressor A-15-RP |
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)] | Single |
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)] | Atmosphere |
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)] | No |
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)] | No |
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)] | 0.0530205 |
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)] | 1.8385833 |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | Compressor B-16-BV |
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)] | Single |
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)] | Atmosphere |
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)] | No |
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)] | No |
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)] | 0.0469869 |
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)] | 1.6293562 |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | Compressor B-16-IV |
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)] | Single |
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)] | Atmosphere |
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)] | Yes |
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)] | No |
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)] | 0.285007 |
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)] | 9.8831324 |
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)] | Compressor B-16-RP |
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)] | Single |
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)] | Atmosphere |
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)] | No |
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)] | No |
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)] | 0.3318025 |
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)] | 11.5058504 |
Component Type [98.236(q)(2)(i)] | Compressor Components, Gas Service - Valve |
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)] | 0 |
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)] | 0 |
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)] | 0 |
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)] | 0 |
Component Type [98.236(q)(2)(i)] | Compressor Components, Gas Service - Connector |
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)] | 0 |
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)] | 0 |
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)] | 0 |
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)] | 0 |
Component Type [98.236(q)(2)(i)] | Compressor Components, Gas Service - Open-ended Line |
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)] | 0 |
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)] | 0 |
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)] | 0 |
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)] | 0 |
Component Type [98.236(q)(2)(i)] | Compressor Components, Gas Service - Pressure Relief Valve |
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)] | 0 |
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)] | 0 |
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)] | 0 |
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)] | 0 |
Component Type [98.236(q)(2)(i)] | Compressor Components, Gas Service - Meter or Instrument |
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)] | 0 |
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)] | 0 |
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)] | 0 |
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)] | 0 |
Component Type [98.236(q)(2)(i)] | Compressor Components, Gas Service - Other |
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)] | 0 |
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)] | 0 |
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)] | 0 |
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)] | 0 |
Component Type [98.236(q)(2)(i)] | Non-Compressor Components, Gas Service - Valve |
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)] | 3 |
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)] | 8784 |
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)] | 0.0978875 |
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)] | 3.1670466 |
Component Type [98.236(q)(2)(i)] | Non-Compressor Components, Gas Service - Connector |
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)] | 0 |
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)] | 0 |
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)] | 0 |
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)] | 0 |
Component Type [98.236(q)(2)(i)] | Non-Compressor Components, Gas Service - Open-ended Line |
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)] | 0 |
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)] | 0 |
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)] | 0 |
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)] | 0 |
Component Type [98.236(q)(2)(i)] | Non-Compressor components, Gas Service - Pressure Relief Valve |
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)] | 0 |
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)] | 0 |
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)] | 0 |
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)] | 0 |
Component Type [98.236(q)(2)(i)] | Non-Compressor components, Gas Service - Meter or Instrument |
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)] | 0 |
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)] | 0 |
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)] | 0 |
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)] | 0 |
Component Type [98.236(q)(2)(i)] | Non-Compressor components, Gas Service - Other |
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)] | 0 |
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)] | 0 |
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)] | 0 |
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)] | 0 |