Facility Name:Cotton Belt Compressor Station
Facility Identifier:
Facility Reporting Year:2019
Facility Location:
Address: 2400 Coppell Rd
City: DFW Airport
State: TX
Postal Code: 75261

Facility Site Details:
CO2 equivalent emissions from facility subparts C-II, SS, and TT (metric tons):31,327.3
CO2 equivalent emissions from supplier subparts LL-QQ (metric tons):
Biogenic CO2 emissions from facility subparts C-II, SS, and TT (metric tons):0
Cogeneration Unit Emissions Indicator:N
GHG Report Start Date:2019-01-01
GHG Report End Date:2019-12-31
Description of Changes to Calculation Methodology:
Plant Code Indicator:N
Primary NAICS Code:211120
Second Primary NAICS Code:

Parent Company Details:
Parent Company Name:THE WILLIAMS COS INC
Address:One Williams Center, Tulsa,  OK 74172
Percent Ownership Interest:100

Subpart C: General Stationary Fuel Combustion

Gas Information Details

Gas NameCarbon Dioxide
Gas Quantity18,438 (Metric Tons)
Own Result?

Gas NameBiogenic Carbon dioxide
Gas Quantity0 (Metric Tons)
Own Result?

Gas NameMethane
Gas Quantity0.35 (Metric Tons)
Own Result?

Gas NameNitrous Oxide
Gas Quantity0.035 (Metric Tons)
Own Result?

Unit Details:
Unit Name : GP-1
Unit Type : OCS (Other combustion source)
Unit Description :
Other Unit Name :
Small Unit Aggregation Details:
Use Ivt Indicator: Y
Highest Maximum Rated Heat Input Capacity: 13.10
Cumulative Maximum Rated Heat Input Capacity: 64.1

Emission Details:
Annual CO2 mass emissions from sorbent: 0 (Metric Tons)
Annual Biogenic CO2 Emissions: 0 (metric tons)
Annual Fossil fuel based CO2 Emissions: 18438.0 (metric tons)

Tier Fuel Details:
Fuel : Natural Gas (Weighted U.S. Average)
Tier Name : Tier 2 (Equation C-2a)
Tier Methodology Start Date : 2019-01-01
Tier Methodology End Date : 2019-12-31
Frequency of HHV determinations : Semiannually

Tier 2 Monthly HHV Details :
JanuaryFebruaryMarchAprilMayJuneJulyAugustSeptemberOctoberNovemberDecember
Y N Y Y Y Y N Y Y Y Y Y

Fuel Emission Details :
Total CO2 emissionsTotal CH4 emissionsTotal N2O emissionsTotal CH4 emissions CO2eTotal N2O emissions CO2e
18438.0 (Metric Tons) 0.35 (Metric Tons) 0.035 (Metric Tons) 8.7 (Metric Tons) 10.4 (Metric Tons)



Subpart W: Petroleum and Natural Gas Systems

Gas Information Details

Gas NameCarbon Dioxide
Gas Quantity11,559.1 (Metric Tons)
Own Result?

Gas NameMethane
Gas Quantity52.44 (Metric Tons)
Own Result?

Gas NameNitrous Oxide
Gas Quantity0 (Metric Tons)
Own Result?


SubpartWSummaryDetails:
Industry Segment Number3
Industry Segment NameOnshore natural gas processing [98.230(a)(3)]
Total Reported CO2 Emissions (mt CO2)11559.1
Total CO2e Emissions (mt CO2e)12870.1
Total Reported CH4 Emissions (mt CH4)52.44
Total Reported N2O Emissions (mt N2O)0.000


SubpartWSourceReportingFormRowDetails:
Source Reporting FormOnshore Production [98.236(aa)(1)]
Required for Selected Industry SegmentNo
Source Reporting FormFacility Overview [98.236(aa)(2-11)]
Required for Selected Industry SegmentYes
Source Reporting FormNatural Gas Pneumatic Devices [98.236(b)]
Required for Selected Industry SegmentNo
Total Reported CO2 Emissions (mt CO2)0.0
Total Reported CH4 Emissions (mt CH4)0.00
Source Reporting FormNatural Gas Driven Pneumatic Pumps [98.236(c)]
Required for Selected Industry SegmentNo
Total Reported CO2 Emissions (mt CO2)0.0
Total Reported CH4 Emissions (mt CH4)0.00
Source Reporting FormAcid Gas Removal Units [98.236(d)]
Required for Selected Industry SegmentYes
Total Reported CO2 Emissions (mt CO2)11456.1
Source Reporting FormDehydrators [98.236(e)]
Required for Selected Industry SegmentYes
Total Reported CO2 Emissions (mt CO2)93.0
Total Reported CH4 Emissions (mt CH4)2.13
Total Reported N2O Emissions (mt N2O)0.000
Source Reporting FormWell Venting for Liquids Unloading [98.236(f)]
Required for Selected Industry SegmentNo
Total Reported CO2 Emissions (mt CO2)0.0
Total Reported CH4 Emissions (mt CH4)0.00
Source Reporting FormCompletions and Workovers with Hydraulic Fracturing [98.236(g)]
Required for Selected Industry SegmentNo
Total Reported CO2 Emissions (mt CO2)0.0
Total Reported CH4 Emissions (mt CH4)0.00
Total Reported N2O Emissions (mt N2O)0.000
Source Reporting FormCompletions and Workovers without Hydraulic Fracturing [98.236(h)]
Required for Selected Industry SegmentNo
Total Reported CO2 Emissions (mt CO2)0.0
Total Reported CH4 Emissions (mt CH4)0.00
Total Reported N2O Emissions (mt N2O)0.000
Source Reporting FormBlowdown Vent Stacks [98.236(i)]
Required for Selected Industry SegmentYes
Total Reported CO2 Emissions (mt CO2)0.1
Total Reported CH4 Emissions (mt CH4)0.74
Source Reporting FormAtmospheric Storage Tanks [98.236(j)]
Required for Selected Industry SegmentNo
Total Reported CO2 Emissions (mt CO2)0.0
Total Reported CH4 Emissions (mt CH4)0.00
Total Reported N2O Emissions (mt N2O)0.000
Source Reporting FormTransmission Storage Tanks [98.236(k)]
Required for Selected Industry SegmentNo
Total Reported CO2 Emissions (mt CO2)0.0
Total Reported CH4 Emissions (mt CH4)0.00
Total Reported N2O Emissions (mt N2O)0.000
Source Reporting FormWell Testing [98.236(l)]
Required for Selected Industry SegmentNo
Total Reported CO2 Emissions (mt CO2)0.0
Total Reported CH4 Emissions (mt CH4)0.00
Total Reported N2O Emissions (mt N2O)0.000
Source Reporting FormAssociated Gas Venting and Flaring [98.236(m)]
Required for Selected Industry SegmentNo
Total Reported CO2 Emissions (mt CO2)0.0
Total Reported CH4 Emissions (mt CH4)0.00
Total Reported N2O Emissions (mt N2O)0.000
Source Reporting FormFlare Stacks [98.236(n)]
Required for Selected Industry SegmentYes
Total Reported CO2 Emissions (mt CO2)0.0
Total Reported CH4 Emissions (mt CH4)0.00
Total Reported N2O Emissions (mt N2O)0.000
Source Reporting FormCentrifugal Compressors [98.236(o)]
Required for Selected Industry SegmentYes
Total Reported CO2 Emissions (mt CO2)0.0
Total Reported CH4 Emissions (mt CH4)0.00
Source Reporting FormReciprocating Compressors [98.236(p)]
Required for Selected Industry SegmentYes
Total Reported CO2 Emissions (mt CO2)9.3
Total Reported CH4 Emissions (mt CH4)45.94
Source Reporting FormEquipment Leaks Surveys and Population Counts [98.236(q,r)]
Required for Selected Industry SegmentYes
Total Reported CO2 Emissions (mt CO2)0.6
Total Reported CH4 Emissions (mt CH4)3.63
Source Reporting FormOffshore Petroleum and Natural Gas Production [98.236(s)]
Required for Selected Industry SegmentNo
Total Reported CO2 Emissions (mt CO2)0.0
Total Reported CH4 Emissions (mt CH4)0.00
Total Reported N2O Emissions (mt N2O)0.000
Source Reporting FormEnhanced Oil Recovery Injection Pumps [98.236(w)]
Required for Selected Industry SegmentNo
Total Reported CO2 Emissions (mt CO2)0.0
Source Reporting FormEnhanced Oil Recovery Hydrocarbon Liquids [98.236(x)]
Required for Selected Industry SegmentNo
Total Reported CO2 Emissions (mt CO2)0.0
Source Reporting FormCombustion Equipment at Onshore Petroleum and Natural Gas Production Facilities, Onshore Petroleum and Natural Gas Gathering and Boosting Facilities, and Natural gas Distribution Facilities [98.236(z)]
Required for Selected Industry SegmentNo
Total Reported CO2 Emissions (mt CO2)0.0
Total Reported CH4 Emissions (mt CH4)0.00
Total Reported N2O Emissions (mt N2O)0.000


FacilityOverviewDetails:


FacilityOverviewNaturalGasProcessingRowDetails:
Average mole fraction of CH4 in natural gas received [98.236(aa)(3)(v)]0.9452
Average mole fraction of CO2 in natural gas received [98.236(aa)(3)(vi)]0.0401
Does the facility fractionate NGLs? [98.236(aa)(3)(vii)]No


AcidGasRemovalUnitsDetails:
mt CO211456.1
Did the Facility have any acid gas removal units that vent directly to the atmosphere, to a flare or engine, or to a sulfur recovery plant subject to reporting under 98.232 [98.236(d)]?Yes
Were missing data procedures used for any parameters to calculate GHG emissions? [98.235]No


AcidGasInfoRowDetails:
Unit ID or Name [98.236(d)(1)(i)]Cotton Belt CF Amine 1
Total feed rate entering the acid gas removal unit for the year (million cubic feet) [98.236(d)(1)(ii)]5218
Calculation Method Used (Select from list) [98.236(d)(1)(iii)]Calculation Methodology 4 [98.233(d)(4)]
Are any CO2 emissions from the acid gas removal unit recovered and transferred outside the facility? (Yes / No) [98.236(d)(1)(iv)]No
Total CO2 Emissions (mt CO2) [98.236(d)(1)(v)]11456.0682577


AcidGasCalcMethod4EmissionsRowDetails:
Unit ID or Name [98.236(d)(1)(i)]Cotton Belt CF Amine 1
Name of simulation software package used [98.236(d)(2)(iii)(A)]Promax
Natural gas feed temperature (°F) [98.236(d)(2)(iii)(B)]100
Natural gas feed pressure (psi) [98.236(d)(2)(iii)(C)]500
Natural gas feed flow rate (standard cubic feet per minute) [98.236(d)(2)(iii)(D)]9927.7016743
Acid gas content of feed natural gas (mole percent) [98.236(d)(2)(iii)(E)]4.27
Acid gas content of outlet natural gas (mole percent) [98.236(d)(2)(iii)(F)]0.10177
Unit operating hours (excluding downtime for maintenance or standby) [98.236(d)(2)(iii)(G)]8760
Exit temperature of the natural gas (°F) [98.236(d)(2)(iii)(H)]120
Solvent pressure (psi) [98.236(d)(2)(iii)(I)]500
Solvent temperature (°F) [98.236(d)(2)(iii)(J)]140
Solvent circulation rate (gallons per minute) [98.236(d)(2)(iii)(K)]150
Solvent weight (pounds per gallon) [98.236(d)(2)(iii)(L)]50


DehydratorsDetails:
mt CO293.0
mt CH42.13
mt N2O0.000
Did the facility have any glycol dehydrators with annual average daily natural gas throughputs greater than or equal to 0.4MMscfd subject to reporting under 98.232 [98.236(e)]?Yes
Did the facility have any glycol dehydrators with annual average daily natural gas throughputs less than 0.4MMscfd subject to reporting under 98.232 [98.236(e)]?No
Did the facility have any desiccant dehydrators subject to reporting under 98.232 [98.236(e)]?No
Were missing data procedures used for any parameters to calculate GHG emissions? [98.235]No


SmallGlycolDehydrators:
Emissions vented to flare or regenerator firebox/fire tubes
Emissions that were not vented to a flare or regenerator firebox/fire tubes


DessicantDehydrators:
Emissions vented to flare or regenerator firebox/fire tubes
Emissions that were not vented to a flare or regenerator firebox/fire tubes


GlycolDehydratorsMoreThanSpecifiedValueRowDetails:
Unit ID or Name [98.236(e)(1)(i)]Barnett - Cotton Belt -- NG Plant --- TARRANT, TX (439) 415 - Dehy - B-East (Central Processing Worksheet)
Glycol dehydrator feed natural gas flow rate determined by engineering estimate based on best available data (MMscfd) [98.236(e)(1)(ii)]14.837
Dehydrator feed natural gas water content (pounds per MMscf) [98.236(e)(1)(iii)]49.94
Dehydrator outlet natural gas water content (pounds per MMscf) [98.236(e)(1)(iv)]2.42
Glycol dehydrator absorbent circulation pump type [98.236(e)(1)(v)]Electric
Dehydrator absorbent circulation rate (gallons per minute) [98.236(e)(1)(vi)]4
Report type of absorbent used [98.236(e)(1)(vii)]Triethylene glycol (TEG)
Report whether stripper gas is used in glycol dehydrator [98.236(e)(1)(viii)]No
Report whether a flash tank separator is used in glycol dehydrator [98.236(e)(1)(ix)]Yes
Total time the glycol dehydrator is operating (hours) [98.236(e)(1)(x)]8760
Temperature of the wet natural gas (°F) [98.236(e)(1)(xi)]87
Pressure of the wet natural gas (psig) [98.236(e)(1)(xii)]736
Concentration of CO2 in wet natural gas (mole fraction) [98.236(e)(1)(xiv)]0.0401
Concentration of CH4 in wet natural gas (mole fraction) [98.236(e)(1)(xiii)]0.944
Were any dehydrator emissions vented to a vapor recovery device? [98.236(e)(1)(xv)]No
Were any dehydrator emissions vented to a flare or regenerator firebox/fire tubes? [98.236(e)(1)(xvi)]Yes
CO2 Emissions from Flares or Regenerators (mt CO2) [98.236(e)(1)(xvi)(A)]93.0171407
CH4 Emissions from Flares or Regenerators (mt CH4) [98.236(e)(1)(xvi)(B)]2.1252136
N2O Emissions from Flares or Regenerators (mt N2O) [98.236(e)(1)(xvi)(C)]0.000207
Were any dehydrator emissions vented to the atmosphere without being routed to a flare or regenerator firebox/fire tubes? [98.236(e)(1)(xvii)]No


BlowdownVentStacksDetails:
mt CO20.1
mt CH40.74
Did the facility have any blowdown vent stacks subject to reporting under 98.232 [98.236(i)]?Yes
Were missing data procedures used for any parameters to calculate GHG emissions? [98.235]No
How were emissions determined? [98.236(i)]Calculated by equipment or event type


BlowdownEquipmentOrEventEmissionsRowDetails:
Equipment or event type [98.236(i)(1)] [98.236(i)(2)]Facility piping
Total number of blowdowns for equipment or event type, N [98.236(i)(1)(i)]0
Annual total CO2 emissions for each equipment or event type (mt CO2) [98.236(i)(1)(ii)]0
Annual total CH4 emissions for each equipment or event type (mt CH4) [98.236(i)(1)(iii)]0
Equipment or event type [98.236(i)(1)] [98.236(i)(2)]Pipeline venting
Total number of blowdowns for equipment or event type, N [98.236(i)(1)(i)]0
Annual total CO2 emissions for each equipment or event type (mt CO2) [98.236(i)(1)(ii)]0
Annual total CH4 emissions for each equipment or event type (mt CH4) [98.236(i)(1)(iii)]0
Equipment or event type [98.236(i)(1)] [98.236(i)(2)]Compressors
Total number of blowdowns for equipment or event type, N [98.236(i)(1)(i)]32
Annual total CO2 emissions for each equipment or event type (mt CO2) [98.236(i)(1)(ii)]0.0902947
Annual total CH4 emissions for each equipment or event type (mt CH4) [98.236(i)(1)(iii)]0.7001984
Equipment or event type [98.236(i)(1)] [98.236(i)(2)]Scrubbers/strainers
Total number of blowdowns for equipment or event type, N [98.236(i)(1)(i)]0
Annual total CO2 emissions for each equipment or event type (mt CO2) [98.236(i)(1)(ii)]0
Annual total CH4 emissions for each equipment or event type (mt CH4) [98.236(i)(1)(iii)]0
Equipment or event type [98.236(i)(1)] [98.236(i)(2)]Pig launchers and receivers
Total number of blowdowns for equipment or event type, N [98.236(i)(1)(i)]3
Annual total CO2 emissions for each equipment or event type (mt CO2) [98.236(i)(1)(ii)]0.005095
Annual total CH4 emissions for each equipment or event type (mt CH4) [98.236(i)(1)(iii)]0.0395093
Equipment or event type [98.236(i)(1)] [98.236(i)(2)]Emergency shutdowns
Total number of blowdowns for equipment or event type, N [98.236(i)(1)(i)]0
Annual total CO2 emissions for each equipment or event type (mt CO2) [98.236(i)(1)(ii)]0
Annual total CH4 emissions for each equipment or event type (mt CH4) [98.236(i)(1)(iii)]0
Equipment or event type [98.236(i)(1)] [98.236(i)(2)]All other equipment with a physical volume greater than or equal 50 cubic feet
Total number of blowdowns for equipment or event type, N [98.236(i)(1)(i)]0
Annual total CO2 emissions for each equipment or event type (mt CO2) [98.236(i)(1)(ii)]0
Annual total CH4 emissions for each equipment or event type (mt CH4) [98.236(i)(1)(iii)]0


FlareStacksDetails:
mt CO20.0
mt CH40.00
mt N2O0.000
Did the facility have flare stacks subject to reporting under 98.232 [98.236(n)]?No


CentrifugalCompressorsDetails:
mt CO20.0
mt CH40.00
Did the facility have any centrifugal compressors subject to reporting under 98.232 [98.236(o)]?No


ReciprocatingCompressorsDetails:
mt CO29.3
mt CH445.94
Did the facility have any reciprocating compressors subject to reporting under 98.232 [98.236(p)]?Yes
Were missing data procedures used for any parameters to calculate GHG emissions? [98.235]No


ReciprocatingCompressorsActivityDataRowDetails:
Unique name or ID for reciprocating compressor [98.236(p)(1)(i)]MC2059
Total time in operating-mode (hours) [98.236(p)(1)(ii)]5814
Total time in standby-pressurized-mode (hours) [98.236(p)(1)(iii)]2880
Total time in not-operating-depressurized-mode (hours) [98.236(p)(1)(iv)]66
Compressor measured in operating-mode? [98.236(p)(1)(v)]Yes
Compressor measured in standby-pressurized-mode? [98.236(p)(1)(vi)]No
Compressor measured in not-operating-depressurized-mode? [98.236(p)(1)(vii)]No
Compressor had blind flanges installed? [98.236(p)(1)(xii)]No
Power output of compressor driver (hp) [98.236(p)(1)(xiii)]1380
Compressor had scheduled depressurized shutdown during reporting year? [98.236(p)(1)(xiv)]Yes
Unique name or ID for reciprocating compressor [98.236(p)(1)(i)]MC2060
Total time in operating-mode (hours) [98.236(p)(1)(ii)]2895
Total time in standby-pressurized-mode (hours) [98.236(p)(1)(iii)]1617
Total time in not-operating-depressurized-mode (hours) [98.236(p)(1)(iv)]12
Compressor measured in operating-mode? [98.236(p)(1)(v)]No
Compressor measured in standby-pressurized-mode? [98.236(p)(1)(vi)]No
Compressor measured in not-operating-depressurized-mode? [98.236(p)(1)(vii)]No
Compressor had blind flanges installed? [98.236(p)(1)(xii)]Yes
Dates for blind flange installation (mm/dd/yyyy - mm/dd/yyyy) [98.236(p)(1)(xii)]08/06/2019-12/31/2019
Power output of compressor driver (hp) [98.236(p)(1)(xiii)]1380
Compressor had scheduled depressurized shutdown during reporting year? [98.236(p)(1)(xiv)]Yes
Unique name or ID for reciprocating compressor [98.236(p)(1)(i)]MC2084
Total time in operating-mode (hours) [98.236(p)(1)(ii)]8656
Total time in standby-pressurized-mode (hours) [98.236(p)(1)(iii)]84
Total time in not-operating-depressurized-mode (hours) [98.236(p)(1)(iv)]20
Compressor measured in operating-mode? [98.236(p)(1)(v)]Yes
Compressor measured in standby-pressurized-mode? [98.236(p)(1)(vi)]No
Compressor measured in not-operating-depressurized-mode? [98.236(p)(1)(vii)]No
Compressor had blind flanges installed? [98.236(p)(1)(xii)]No
Power output of compressor driver (hp) [98.236(p)(1)(xiii)]1380
Compressor had scheduled depressurized shutdown during reporting year? [98.236(p)(1)(xiv)]Yes


ReciprocatingCompressorSourceRowDetails:
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]MC2059
Reciprocating compressor source [98.236(p)(2)(i)(B)]Blowdown valve
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]MC2059BDV
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]MC2059
Reciprocating compressor source [98.236(p)(2)(i)(B)]Isolation valve
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]MC2059ISO
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]MC2059
Reciprocating compressor source [98.236(p)(2)(i)(B)]Rod packing
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]MC2059RPV
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]MC2060
Reciprocating compressor source [98.236(p)(2)(i)(B)]Blowdown valve
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]MC2060BDV
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]MC2060
Reciprocating compressor source [98.236(p)(2)(i)(B)]Isolation valve
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]MC2060ISO
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]MC2060
Reciprocating compressor source [98.236(p)(2)(i)(B)]Rod packing
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]MC2060RPV
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]MC2084
Reciprocating compressor source [98.236(p)(2)(i)(B)]Blowdown valve
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]MC2084BDV
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]MC2084
Reciprocating compressor source [98.236(p)(2)(i)(B)]Isolation valve
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]MC2084ISO
Unique name or ID for reciprocating compressor [98.236(p)(2)(i)(A)]MC2084
Reciprocating compressor source [98.236(p)(2)(i)(B)]Rod packing
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]MC2084RPV


ReciprocatingCompressorsLeakOrVentSampleDataRowDetails:
Unique Name or ID for leak or vent (Specify) [98.236(p)(2)(i)(C)] [98.236(p)(3)(i)(A)]MC2059BDV
Measurement date (mm/dd/yyyy) [98.236(p)(3)(i)(B)]2019-09-06
Measurement method [98.236(p)(3)(i)(C)]Screening/Optical gas imaging
Measured flow rate (standard cubic feet/hour) [98.236(p)(3)(i)(D)]0
Is the measurement location prior to or after commingling with non-compressor emission sources? [98.236(p)(3)(i)(F)]Not manifolded
Compressors in “Operating mode”MC2059
Unique Name or ID for leak or vent (Specify) [98.236(p)(2)(i)(C)] [98.236(p)(3)(i)(A)]MC2059RPV
Measurement date (mm/dd/yyyy) [98.236(p)(3)(i)(B)]2019-09-06
Measurement method [98.236(p)(3)(i)(C)]High volume sampler
Measured flow rate (standard cubic feet/hour) [98.236(p)(3)(i)(D)]0
Is the measurement location prior to or after commingling with non-compressor emission sources? [98.236(p)(3)(i)(F)]Not manifolded
Compressors in “Operating mode”MC2059
Unique Name or ID for leak or vent (Specify) [98.236(p)(2)(i)(C)] [98.236(p)(3)(i)(A)]MC2084BDV
Measurement date (mm/dd/yyyy) [98.236(p)(3)(i)(B)]2019-09-06
Measurement method [98.236(p)(3)(i)(C)]Screening/Optical gas imaging
Measured flow rate (standard cubic feet/hour) [98.236(p)(3)(i)(D)]0
Is the measurement location prior to or after commingling with non-compressor emission sources? [98.236(p)(3)(i)(F)]Not manifolded
Compressors in “Operating mode”MC2084
Unique Name or ID for leak or vent (Specify) [98.236(p)(2)(i)(C)] [98.236(p)(3)(i)(A)]MC2084RPV
Measurement date (mm/dd/yyyy) [98.236(p)(3)(i)(B)]2019-09-06
Measurement method [98.236(p)(3)(i)(C)]High volume sampler
Measured flow rate (standard cubic feet/hour) [98.236(p)(3)(i)(D)]206.1
Is the measurement location prior to or after commingling with non-compressor emission sources? [98.236(p)(3)(i)(F)]Not manifolded
Compressors in “Operating mode”MC2084


ReciprocatingCompressorsEmissionFactorsSampleDataRowDetails:
Compressor Mode [98.236(p)(3)(ii)(A)]Operating
Compressor Source [98.236(p)(3)(ii)(A)]Blowdown valve
Compressor mode-source combination reporter emission factor, EFs,m (standard cubic feet per hour) [98.236(p)(3)(ii)(B)]15.5850833
Total number of compressors measured in the compressor mode-source combination in current reporting year and preceding two reporting years, Countm [98.236(p)(3)(ii)(C)]72
Is the reporter emission factor facility-specific or based on all of the reporter's applicable facilities? [98.236(p)(3)(ii)(D)]All applicable facilities
Compressor Mode [98.236(p)(3)(ii)(A)]Operating
Compressor Source [98.236(p)(3)(ii)(A)]Rod packing
Compressor mode-source combination reporter emission factor, EFs,m (standard cubic feet per hour) [98.236(p)(3)(ii)(B)]222.3929396
Total number of compressors measured in the compressor mode-source combination in current reporting year and preceding two reporting years, Countm [98.236(p)(3)(ii)(C)]149
Is the reporter emission factor facility-specific or based on all of the reporter's applicable facilities? [98.236(p)(3)(ii)(D)]All applicable facilities
Compressor Mode [98.236(p)(3)(ii)(A)]Standby-pressurized
Compressor Source [98.236(p)(3)(ii)(A)]Blowdown valve
Compressor mode-source combination reporter emission factor, EFs,m (standard cubic feet per hour) [98.236(p)(3)(ii)(B)]1.3024091
Total number of compressors measured in the compressor mode-source combination in current reporting year and preceding two reporting years, Countm [98.236(p)(3)(ii)(C)]22
Is the reporter emission factor facility-specific or based on all of the reporter's applicable facilities? [98.236(p)(3)(ii)(D)]All applicable facilities
Compressor Mode [98.236(p)(3)(ii)(A)]Not-operating-depressurized
Compressor Source [98.236(p)(3)(ii)(A)]Isolation valve
Compressor mode-source combination reporter emission factor, EFs,m (standard cubic feet per hour) [98.236(p)(3)(ii)(B)]6.4448182
Total number of compressors measured in the compressor mode-source combination in current reporting year and preceding two reporting years, Countm [98.236(p)(3)(ii)(C)]22
Is the reporter emission factor facility-specific or based on all of the reporter's applicable facilities? [98.236(p)(3)(ii)(D)]All applicable facilities


ReciprocatingCompressorsLeakOrVentDataRowDetails:
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]MC2059BDV
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]Yes
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)]0.0141069
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)]0.0694974
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]MC2059ISO
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]No
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)]0.0015997
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)]0.007881
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]MC2059RPV
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]Yes
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)]0
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)]0
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]MC2060BDV
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]No
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)]0.1776078
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)]0.8749813
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]MC2060ISO
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]No
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)]0.0002909
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)]0.0014329
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]MC2060RPV
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]No
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)]2.4213711
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)]11.928837
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]MC2084BDV
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]Yes
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)]0.0004115
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)]0.002027
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]MC2084ISO
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]No
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)]0.0004848
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)]0.0023882
Unique Name or ID for leak or vent [98.236(p)(2)(i)(C)]MC2084RPV
Leak or vent for a single compressor source or a manifolded group? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(viii)]Single
Where are leak or vent emissions released? [98.236(p)(2)(ii)(A)] [98.236(p)(1)(ix) through (xi)]Atmosphere
Was an "as found" measurement conducted on the leak or vent? [98.236(p)(2)(ii)(B)]Yes
Were continuous measurements conducted on the leak or vent? [98.236(p)(2)(ii)(C)]No
CO2 Emissions vented to atmosphere (mt CO2) [98.236(p)(2)(ii)(D)(1)]6.7094516
CH4 Emissions vented to atmosphere (mt CH4) [98.236(p)(2)(ii)(D)(2)]33.0539816


OtherEmissionsFromEquipmentLeaksDetails:
mt CO20.6
mt CH43.63
Did this facility use leak surveys to calculate emissions from equipment leaks in accordance with 98.232 [per 98.236(q)]?Yes
Were missing data procedures used for any parameters to calculate GHG emissions? [98.235]No
Number of complete equipment leak surveys performed during the calendar year [98.236(q)(1)(i)]1
Optical gas imaging instrument as specified in §60.18 [98.234(a)(1)]Yes
Method 21 [98.234(a)(2)]No
Infrared laser beam illuminated instrument [98.234(a)(3)]No
Acoustic leak detection device [98.234(a)(5)]No
Optical gas imaging instrument as specified in §60.5397a [98.234(a)(6)]No
Method 21 as specified in §60.5397a [98.234(a)(7)]No


GasProcessingEmissionsFactorsRowDetails:
Component Type [98.236(q)(2)(i)]Compressor Components, Gas Service - Valve
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)]0
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)]0
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)]0
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)]0
Component Type [98.236(q)(2)(i)]Compressor Components, Gas Service - Connector
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)]2
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)]8760
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)]0.2874523
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)]1.7959572
Component Type [98.236(q)(2)(i)]Compressor Components, Gas Service - Open-ended Line
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)]0
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)]0
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)]0
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)]0
Component Type [98.236(q)(2)(i)]Compressor Components, Gas Service - Pressure Relief Valve
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)]0
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)]0
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)]0
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)]0
Component Type [98.236(q)(2)(i)]Compressor Components, Gas Service - Meter
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)]0
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)]0
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)]0
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)]0
Component Type [98.236(q)(2)(i)]Non-Compressor Components, Gas Service - Valve
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)]0
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)]0
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)]0
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)]0
Component Type [98.236(q)(2)(i)]Non-Compressor Components, Gas Service - Connector
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)]2
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)]8760
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)]0.2936231
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)]1.8345108
Component Type [98.236(q)(2)(i)]Non-Compressor Components, Gas Service - Open-ended Line
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)]0
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)]0
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)]0
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)]0
Component Type [98.236(q)(2)(i)]Non-Compressor components, Gas Service - Pressure Relief Valve
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)]0
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)]0
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)]0
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)]0
Component Type [98.236(q)(2)(i)]Non-Compressor components, Gas Service - Meter
Total number of surveyed component type identified as leaking, xp [98.236(q)(2)(ii)]0
Average time the surveyed components are assumed to be leaking and operational, Tp,z (hours) [98.236(q)(2)(iii)]0
CO2 Emissions (surveyed components identified as leaking only) (mt CO2) [98.236(q)(2)(iv)]0
CH4 Emissions (surveyed components identified as leaking only) (mt CH4) [98.236(q)(2)(v)]0